Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited Tender
View complete overview of Uttarakhand BRIDCUL Tender
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited - BRIDCUL Tender
Eprocure
Opening Date3 Jul 2024
Closing Date17 Jul 2024
Tender Amount₹ 39,05,000
Costs
EMD
₹ 78,100Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BRID3_73021_1Bid Award Id
ViewTender No
1026/BRIDCUL/875/24 Dated 02/07/2024Tender Authority
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Group -C
98.5
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
133
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1105
-
-
2 X 6 sq. mm + 1 X 4 sq. mm earth wire
75
-
-
2 x 10 sq.mm + 1 x 6 sq.mm. earth wire
40
-
-
4 x 10 sq.mm + 2 x 6 sq.mm. earth wire
294
-
-
4 x 16 sq.mm + 2 x 6 sq.mm. earth wire
42
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.
7
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
26
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
6
-
-
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
3
-
-
Wiring for light/ power plug plug with 2 X 4 sq. mm FRLC PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FRLC PVC insulated copper conductor single core cable for loop earthing as required
780
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
71
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
33
-
-
Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:
-
-
-
2 Pair (4 core)
120
-
-
SITC of EPBAX system extensions 24 analog trunk & 4 Digital Extensions complete in all respest.
1
-
-
Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.6mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe.
-
-
-
5 Pair telephone cable
100
-
-
Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.
-
-
-
10 pair tag block
1
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20mm dia PVC conduit
80
-
-
25mm dia PVC conduit
100
-
-
32mm dia PVC conduit
20
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required
-
-
-
1 or 2 Module (75mmX75mm)
18
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
-
-
-
5/6 A switch
25
-
-
3 pin 5/6 A socket outlet
25
-
-
Telephone socket outlet
6
-
-
RJ-45 Data Socket outlet
12
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
-
-
-
1 run of cable
360
-
-
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
172
-
-
Installation ,Testing, Commissioning of wall bracket /ceiling
fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including
connections etc. as required.
215
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
-
-
-
Upto 450 mm sweep
9
-
-
Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.
9
-
-
Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI80. The luminaire shall meet IP20 rating with THD 10% and PF 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor.
79
-
-
Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect.
26
-
-
Supply of Surface mounting round 12 Watt 15 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect.
63
-
-
Supply of Surface mounting square 18 to 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, complete in all respect.
29
-
-
Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required.
5
-
-
Supplying of LED mirror light luminaire with 10W watt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor.
13
-
-
Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W, PF0.95, THD 10% at full load, CRI80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect,
4
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan
71
-
-
Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.
-
-
-
300mm EXHAUST FAN
9
-
-
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
-
-
-
63 A,25KA,FP MCCB
1
-
-
100 A,30KA,FPMCCB
1
-
-
Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
12 way, Double Door
2
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
8 way Double door
8
-
-
Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.)
-
-
-
8 way (4 + 24), Double door
2
-
-
Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required
-
-
-
40 amps TP MCB
7
-
-
63 amps TP MCB
1
-
-
40 amps 4P MCB
7
-
-
63 amps 4P MCB
1
-
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required.
-
-
-
25 amps
21
-
-
40 amps
3
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
140
-
-
Double pole
2
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
28
-
-
Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only.
-
-
-
Main LT Panel
-
-
-
Same as above item but following mountings.
-
-
-
INCOMER:-
-
-
-
1 No 160 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity
-
-
-
1 No. Multi Function Meter.
-
-
-
1 Set of phase indicating lamps with Single Pole MCB.
-
-
-
1 Set of ON / OFF indicating lamps with Single Pole MCB.
-
-
-
BUS BARS:-
-
-
-
200 Amps. TP&N aluminium bus bars (25 KA)
-
-
-
OUT GOINGS:-
-
-
-
2 Nos. 100 Amps. FP MCCB thermal magnetic release
-
-
-
2 Nos. 63 Amps. FP MCCB thermal magnetic release
-
-
-
3 Nos. 32 Amps. DP MCB
-
-
-
2 Nos. Space & Spare
1
-
-
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
1
-
-
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.
2
-
-
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
40
-
-
Supply , Installtion , Testing and Comissioning of Landline Speaker Phone With Caller Id.
6
-
-
Supply , Installtion , Testing and Comissioning of 24 PORT Network Switch Layer 2
1
-
-
Supply , Installtion , Testing and Comissioning of 4U networking/server rack
1
-
-
Supply , Installtion , Testing and Comissioning of CAT 6A patch cord 3 feet .
12
-
-
Supply , Installtion , Testing and Comissioning of CAT 2 pair telephone line cord 1.5 feet .
6
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
Above 95 sq.mm. and upto 185 sq.mm.
50
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
-
-
-
Up to 35 sq.mm.
80
-
-
Above 95 sq.mm. and upto 185 sq.mm.
30
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required
-
-
-
Up to 35 sq.mm.
10
-
-
Above 95 sq.mm. and upto 185 sq.mm.
10
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required
-
-
-
Upto 35 sq. mm (clamped with 1mm thick saddle
50
-
-
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp
10
-
-
Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment
-
-
-
3.5 x 120 sq.mm
100
-
-
3.5 x 35 sq.mm
20
-
-
3.5 x 25 sq.mm.
120
-
-
Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.
-
-
-
3½ X 25 sq. mm (28mm)
4
-
-
3½ X 35 sq. mm (32mm)
2
-
-
3½ X 120 sq. mm (45mm)
2
-
-
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
-
-
-
100mm dia
30
-
-
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
-
-
-
100 mm wide x 50 mm depth x 1.6 mm thickness.
10
-
-
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
-
-
-
100 mm wide x 50 mm depth x 1.6 mm thickness.
1
-
-
Supply, Installation, Testing and Commissioning of true parallel redundant 1 X 5 kVA, online, UPS system suitable for providing power supply to emergency lighting at station & viaduct, Platform edge door and Computerised Control panel load of approved make, suitable for incoming 415 volts, single phase +10 % ‐ 20%, 50 Hz, supply and single phase output voltage, variation ± 1%, including transformer, rectifier/dual converter, static switch, inverter, filter, Bypass & static transfer switch for automatic switch over without giving any break of power, maintenance bypass switch, Micro processor/ software controlled annunciation,protection(including against input phase reverssal), and menu run diagnostic module,associated cabling and connections/ terminations, erection including associated foundation/ masonorey or RCC work for mounting on base channels etc. complete as per specifications and as required.
Supply, Installation, Testing and Commissioning of lead acid sealed maintenance free suitable for 60‐minute‐battery backup to the UPS set. Battery shall comply with relevant regulations & Battery racks shall be made of acid resistant material.
-
-
-
UPS described as above
1
-
-
Supply and fixing of fire extinguishers, ABC Type 9.00 kg. capacity(ISI Marked IS : 15683 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work.
3
-
-
Supply and fixing of CO2 type fire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work.
3
-
-
Supplying, installation & testing of 7.0 m high octagonal GI pole with single arm as per approved sample made from 3 mm sheet steel (Grade S 355 J0) with top diameter as 75mm and bottom dia as 150mm and base plate of 240x240x16 mm with suitable slot shaped holes for mounting the same on a shallow foundation, GI weather proof junction box with 16A SP MCB, loop-in-loop out terminals for 2nos. 2Cx6 sq.mm YWY cables and 2x2.5 sq.mm copper conductor from junction box to fitting and connected accessories as required etc. Contractor to include the cost of RCC foundation for pole as per structural detail.
10
-
-
Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 70Watt. to 80 Watt and Confirming to IP66 protection having Company LOGO Engraved complete in all respect with 4000-5000 system lumens High Power LED with lenses, 110lm/W, PF0.95, THD 10% at full load, CRI70, Avg Life Class 50000Hrs@L70,fitting itself suitable for 60-65mm OD pipe
10
-
-
S & F cast aluminium 4 mtr. Pole for post top light complete as required.
6
-
-
Supply and fixing of decorative 30 to 40 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect.
6
-
-
Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
-
-
-
1 output per phase and suitable for single phase supply
3
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
-
-
-
Up to 35 sq.mm.
250
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required
-
-
-
up to 35 sq.mm.
50
-
-
Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment
-
-
-
Size 10 sq.mm x 3 core
300
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
-
-
-
3 X 10 sq. mm (22mm)
32
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
3
-
-
Supplying and laying 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
30
-
-
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
20
-
-