Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited Tender
View complete overview of Uttarakhand BRIDCUL Tender
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited - BRIDCUL Tender
Security and Emergency Services
Eprocure
Opening Date10 Oct 2024
Closing Date23 Oct 2024
Tender Amount₹ 42,24,000
Costs
EMD
₹ 84,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BRID3_76891_2Bid Award Id
ViewTender No
1750/BRIDCUL/99/24 Dated 05/10/2024Tender Authority
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head
1
-
-
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head
1
-
-
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for
operation on 415V, 3 phase, 50Hz Ac Supply with
enclosure protection class IP 42 as required : INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch
Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING
( Note : All outgoing feeders for pumps should have
digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump: 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL: Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification
1
-
-
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm. Dia (Fire Hydrant & Sprinkler Pipe)
193.2
-
-
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
1
-
-
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia
6
-
-
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 150mm dia
6
-
-
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
3
-
-
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
6
-
-
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
6
-
-
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade
as required.
3
-
-
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
3
-
-
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150mm dia
3
-
-
Providing, fixing, testing & commissioning of
installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia
5
-
-
Providing and fixing of 101 SOMAIYA'S 10 liter GALVANIZEDMILD STEEL FIRE BUCKET (Firesuppression hand tools) complete in all aspects as per directions of Engineer-in-Charge
3
-
-
Providing and fixing of AAAG Mild Steel sheet Double Door(1)Fire Hose Cabinet, Warranty 1 Year M.S. FIRE HOSE BOX (910MM X610MM X290MM) complete in all aspects as per directions of Engineer-in-Charge
3
-
-
Providing and fixing of Fire Quit--Padma Industries PortableFire Extinguishers as per IS 15683(2018) Low Pressure Extinguisher(Service Pressure ≤19 bar) PowderBased (as per IS 4308 Class -A Fire Quit Unregistered Brand Manufactured by: Padma Industries complete in all aspects as per directions of Engineer-in-Charge
22
-
-
Providing and fixing of HIRA Conforming to IS:926 latestFIREMAN'S AXE 3 kg (Fire suppressionhand tools) HIRA complete in all aspects as per directions of Engineer-in-Charge
3
-
-
HVAC works
-
-
-
Ventilation Equipments: SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-3 type) confirming to IS - 325-IP - 55 with class `H' insulation. Motor shall be of high temperature resistance "Class H Smoke Spill" 250° C for 2 hrs. Fan shall be EN 12101-3 Certified & CE/UL Listed for high temprature. Fan efficiency should not be less than 70 %, noise level should not be more than 80 db @ 3 m distance when measured in hemisperical reverberant room conditions for Normal mode Fans and noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions for Emergency mode Fans. Fans should be as per specification and drawings (As per Vent. Fan Schedule ). (Normal & Smoke Ventilation) 10500 CFM, 25 mmwg SP For Normal & Smoke extract
4
-
-
Supply,installation,testing and commissioning of Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver & bird screen. 200 mm dia propeller fan, with single phase motor
6
-
-
Supply,installation,testing and commissioning of Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver & bird screen.300 mm dia propeller fan, with single phase motor
1
-
-
Supply,Installation,balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, supports etc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. Spcl. Note: All Duct Supprots incl. Supply, Fabrication, installation and testing of Steel Wire Ropes and Hangers, Supports and Modular system – Wire rope Supports (double channel wedge lock, unlocking device should not be integral part of grip for added safety) complete with end fixing. Wire Hangers shall be independently tested by reputed third party testing organization to sustain safe working load for 120min at elevated temperature of 175 deg. C or above. System shall be in accordance with the approved shop drawings and as required by the specifications 0.63mm (24 gauge) GSS
10
-
-
Supply,Installation,balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, supports etc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. Spcl. Note: All Duct Supprots incl. Supply, Fabrication, installation and testing of Steel Wire Ropes and Hangers, Supports and Modular system – Wire rope Supports (double channel wedge lock, unlocking device should not be integral part of grip for added safety) complete with end fixing. Wire Hangers shall be independently tested by reputed third party testing organization to sustain safe working load for 120min at elevated temperature of 175 deg. C or above. System shall be in accordance with the approved shop drawings and as required by the specifications 0.8 mm (22 gauge) GSS
90
-
-
Supply,Installation,balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, supports etc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. Spcl. Note: All Duct Supprots incl. Supply, Fabrication, installation and testing of Steel Wire Ropes and Hangers, Supports and Modular system – Wire rope Supports (double channel wedge lock, unlocking device should not be integral part of grip for added safety) complete with end fixing. Wire Hangers shall be independently tested by reputed third party testing organization to sustain safe working load for 120min at elevated temperature of 175 deg. C or above. System shall be in accordance with the approved shop drawings and as required by the specifications 1.0mm (20 gauge) GSS
200
-
-
Supplying and fixing of Extruded aluminium supply and return air grilles/diffusers/louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. Aluminium supply air grilles with damper.
-
-
-
Supplying and fixing of Extruded aluminium supply and return air grilles/diffusers/louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. Aluminium Exh./return air grilles without damper.
4.5
-
-
Fresh Air/Exhaust Air Louvers Supplying and fixing of extruded aluminium louvres with frame bird screeen , mounting arrangement etc. as per specifications and drawings. Fresh Air/Exhaust Louvers
5
-
-
Supply,Installation,Testing and commissioning of doble layer canvas connection (Fire retardent) as per specification.
10
-
-
SITC for 2Hours fire rated Ductwork paint tested as per BS 476 Part 6, 7, 20 & 24,for life safety ducts, Kitchen Extraction Duct and Car perking ventilation duct along with all the necessary accessories (Sealant magik 32-17 & Gasket class “O”) etc. Details shall be as per tender specifications.
40
-
-
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following LT panels fabricated out of 14 guage CRCA sheet steel in cubical formationwith reinforecment of suitable size angle iron and channel T iron flats. All steel material used in the construction of panels shall be powder coated. A solid busbar shall be provided at the bottom of the panel with two connecting eyes for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase , 4 wire supply system. All the hardware used in the fabrication of the panel shall be galvanized with zinc passivation. The panel shall be compartmentalized to accommodate one feeder in each compartment. A vertcal cable alley of suitable width shall be provided to serve on or two vertical feeder sections. Also the opening between the busbar chamber and the feeder section shall be shrouded with bakelite / hylam sheet with min.3 mm thickness. The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire. All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing control modules. vent. Fan Panel HVAC Fan Panel MCC-01 (1 Nos.) Incoming/ougoing 1 nos. 6-10 A,TP MPCB (with 4 Kw DOL) Phase indicating lights with control fuses.Breaker ON/OFF/TRIP indicating ligh Panel as described above and in drawings.
4
-
-
Supply, laying, affecting connections and Testing of the following sizes of 1.1 KV armoured PVC insulated aluminium/ copper conductor cables. Cables shall be inclusive of all clamps,saddles,screws,cable identification tags, cable terminal joints including terminal lugs, insulating tapes, affecting terminal connections to the equipment as per the specifications and as required. Quoted price shall be inclusive of GI perforated cable tray, support. 3Cx16 Sqmm Al.
-
-
-
Supply, laying, affecting connections and Testing of the following sizes of 1.1 KV armoured PVC insulated aluminium/ copper conductor cables. Cables shall be inclusive of all clamps,saddles,screws,cable identification tags, cable terminal joints including terminal lugs, insulating tapes, affecting terminal connections to the equipment as per the specifications and as required. Quoted price shall be inclusive of GI perforated cable tray, support. 3Cx06 Sqmm Al.
100
-
-
CONTROL WIRING Supply, laying, affecting connections and Testing of the following sizes of control cum transmission wiring to be laid in MS conduits between indoor units and outdoor units.2C x1.5 Sqmm copper wiring
5
-
-
Supply, laying, affecting connections and Testing of the following sizes of control cum transmission wiring to be laid in MS conduits between indoor units and outdoor units. 8C x1.5 Sqmm copper wiring
40
-
-
Supplying and installing following size of perforated Hot dipped G.I. cable trays, G.I. bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with suitable suspenders above in general points complete as required. 100 mm. Width x 50mm. Depth x 1.6mm. Thickness.
30
-
-
Supplying and Laying following size of G.I. strip / G.I. wire on surface or in recess for loop earthing alongwith the existing surface/ recessed conduit/ submain wiring / on cable tray/ on surface including G.I. clamps etc. complete as required. 6 SWG G.I. wire
30
-
-