Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited Tender
View complete overview of Uttarakhand BRIDCUL Tender
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited - BRIDCUL Tender
Electrical and Electronics
Solar Installation and Products
Eprocure
Opening Date11 Jun 2024
Closing Date6 Jul 2024
Tender Amount₹ 3,49,08,000
Costs
EMD
₹ 6,98,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BRID3_72222_2Bid Award Id
ViewTender No
914/BRIDCUL/914/24 Dated 06/06/2024Tender Authority
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
184
-
-
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
180
-
-
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
690
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
500
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Upto 35 sq. mm
260
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 35 sq. mm and upto 95 sq. mm
100
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 95 sq. mm and upto 185 sq. mm
130
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 185 sq. mm and upto 400 sq. mm
400
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/existing open trence/as required. Upto 35 sq. mm
100
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/existing open trence/as required. Above 35 sq. mm and upto 95 sq. mm
50
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/existing open trence/as required. Above 95 sq. mm and upto 185 sq. mm
50
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray /surface on wall as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
175
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray /surface on wall as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
390
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray /surface on wall as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
300
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray /surface on wall as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
80
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm
100
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 3½ X 95 sq. mm (45mm)
16
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 3½ X 120 sq. mm (45mm)
6
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV3½ X 150 sq. mm (50mm)
4
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV3½ X 185 sq. mm (57mm)
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 3½ X 240 sq. mm (62mm)
16
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 4 X 10 sq. mm (25mm)
4
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 4 X 25 sq. mm (28mm)
10
-
-
Erection of metallic/octagonal pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.5 metre and upto 6.5 metre
35
-
-
Providing and making steel pole collar with cement concrete (1cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted)
2.63
-
-
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia
105
-
-
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 100 mm dia
40
-
-
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 150 mm dia
30
-
-
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 250 mm dia
19
-
-
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 300 mm dia
20
-
-
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
600
-
-
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
200
-
-
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
600
-
-
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 4CX10 SQMM AL ARMOURD CABLE
150
-
-
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications.4CX25 SQMM AL ARMOURD CABLE
200
-
-
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3.5CX95 SQMM AL ARMOURD CABLE
390
-
-
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3.5CX120 SQMM AL ARMOURD CABLE
300
-
-
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3.5CX185 SQMM AL ARMOURD CABLE
351
-
-
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3.5CX240 SQMM AL ARMOURD CABLE
400
-
-
Supply of following sizes of XLPE insulated Copper Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 4CX 2.5 SQMM Cu. ARMOURD CABLE
600
-
-
Supply AND Fixing of LED street light fitting not more than 45W SESSP LED STREET LIGHT having System Efficacy =100 lm/W, system output =4500Lumens, THD 10%, Power Factor 0.95, CRI 70, CCT 5700, Full IP 66 ( with out Glue) protected single piece die cast aluminium housing having toughned glass/PC with Impact resistance IK07. LED driver should be Fully metal body Potted & Encapsulated . BIS compliant driver should sustain 440V Stress Voltage protection for 8 Hrs., High Cut off : 325V(+/- 15V) and should have feature of Auto Restart. Driver shall have 4KV Surge protection and feasibility of 10KV external SPD housed in Luminiare and confirming standard IEC60598. Including suitable size GI pipe bracket clamps, nut, bolts and washers complete all as directed.
35
-
-
Supply of 5 mtr galvanised Octagonal Pole with base plate 220 X 220X 12,top 70mm & bottom 130mm made up of 3mm thik suitable for max. wind speed upto 160 Km/hr with Foundation Bolts - Length 600mm, dia as per manufacture recommanded &04 Nos. Bolts manufactured from special steel along with nuts, washer, anchor plates & Templates. SingleArm of upto 600 mm. Shall be provided along with.
35
-
-
HT SUB STATION WORKS S / I /T / C of 11 KV HT VCB Panel comprising of 1 No incoming and outgoing VCB panel Normal system Voltage 630 Amp for incoming Highest system Voltage, 630 Amp for outgoing feeders, 50 HZ rated frequency, 3phase, 3 wire,350 MVA at 11 KV rated continuous current rating at ambient temperature as specified in IS: 13118-199175kV peak) . The 11 kV Switchgear panel shall comprise of 11 kV Vacuum Type circuit breaker, control relay panels, instrument panel and instrument Transformers complete in all respect etc. suitable for indoor use. The equipment shall be totally enclosed, single bus bar, floor mounting metal clad, indoor extensible type, flush fronted horizontal drawout vertical isolation type vacuum circuit breaker,cubicle, dust and vermin proof with necessary isolation arrangement. Panel shall be easily extensible on either side and should be complete with necessary copper connections, small wiring, fuses, and framework with bolts to secure it to the floor & panel shall be provided with heater, door switch with lamps and 15-Ampere power receptacle. The VCB shall be trip free and the breaker control shall be draw out type. The VCBs shall be suitable for operation from 220 V AC. The operating mechanism shall be motor operated spring charged type & there shall be provisions for manual charging of closing spring and emergency hand trip. The motor used for the purpose will be suitable for 220 V AC.The operating mechanism shall work satisfactorily at 85 -110 % of rated supply voltage.
1
-
-
SITC 630 KVA, Three Phase Digital Micro Controlled Servo Stabilizer with High Low Voltage Cut Off, & Change Over. Technical Specifications : Capacity : 630 KVA Input Voltage : 340-460 volts (Phase to Phase) 200-270 volts (Phase to Neutral) Output Voltage : 400 volts ± 1% (Phase to Phase) 230 volts ± 1% (Phase to Neutral) Type : Suitable for:
100% BALANCED/UNBALANCED LOAD
100% BALANCED/UNBALANCED SUPPLY Application : Indoor Type Standard : IS 2026 & IS 9815 Phase : 3-Ph, 4 Wires Frequency : 50 Hz Wave form Distortion : Nil(Negligible) Response Time : Instantaneous (mili sec) Speed of Correction : 20 to 30 V/sec (as required) Mode of Operation : Automatic Suitability : Suitable for all Power Factors.
Duty Cycle : Continuous 24 Hrs. Efficiency : As per IS Standards Losses at No Load : As per IS Standards Losses at Full Load : As per IS Standards Temperature Rise : 45°C Above Ambient Laminations Used : Imported Low Losses CRGO Laminations - M4 Grade. Carbon Brushes Used : Imported High Grade Graphite. Class of Insulation : Class - A , Greater Than 6M ohms Break Down Strength : 1500 volt AC for 1 minutes (for whole unit) Construction - The unit will comprise of 3 No's Individual Single Phase Units of 1/3 rd of the total capacity connected in star configuration. Further, each of the three phases will further comprise of following : 1 No. motorized variable auto transformer, wound on toroidal CRGO laminations with High quality graphite carbons for smooth functioning. 3 nos, 1 No. Digital Micro Controlled Processor Based Control Card with elegant push buttons for oprtations 3/1 1 No. AC Synchronous Servo Motor 3nos ,1 No. Make Buck n Boost series transformer.3 nos
1
-
-
Supply, installation, testing and commissioning of outdoor TYPE, OIL type transformer with copper winding And OLTC having a continuous rating of 630 kVA, 11kV/415 +/- 1% V, 3 phase, 50 Hz, DY-11 vector group, The transformer shall have cable end box for indoor termination of HT cable on HT side and Cable Box for indoor termination on LT side, complete in all respects including standard accessories. .Compliance to BEE Standards AND BIS Standards (IS 1180). SERVOKON DISTRIBUTION TRANSFORMER
1
-
-
Supply of HT (UE) AL XLPE Cable of size 3 C X 150 sq mm.
100
-
-
Supply & fixing of Rubber hand gloves 11 KV Tested.
2
-
-
Supply & fixing of glass framed shock treatment chart both in Hindi & English for treating person suffering due to electric shock mounted on wall hooks.
6
-
-
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass required. (Approx Front area 1.20 sq.mt.)
4
-
-
First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 -
1963
4
-
-
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat of 2.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment), suitable for all voltages not exceeding 3.3 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.
10
-
-
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat of minimum 3.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment),, suitable for all voltages not exceeding 33 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.
10
-
-
Design, Supplying, fixing, testing & commissioning of 415V ,3Phase 50Hz, 4wire system,sheet steel clad,dust & vermin proof cubical & outdoor type floor mounted, free standing Main Distribution Board with IP protection, compartmentalized design and fabricated out of 2mm/1.6mm CRCA sheet steel complete with aluminium Bus Bars, Providing & Fixing of base plate /channel, P/F the following Switchgears,complete with earth Bus Bar throughout the length of the panel,terminal arrangement for incomings/outgoings cables and also outgoing terminations for various sizes of cables,the incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement,adequate size bus duct/cable alley, Sign writing,Painting,Earthing,Numbering,Danger plate etc. Complete as requried,numbering, danger plate etc. complete as required as per specification and drawing. All MCCBs Shall be Ics=100%Icu. SERVO BY-PASS PANEL (Weather Proof) Servo By-Pass Panel-1 (For 630 KVA Servo Stabilizer), 1 No.1000 Amp FP EDO Air Circuit Breaker (of 50KA Ics Value) with microprossor release for O/L, S/C & E/F protection complete with interlocking with I/C & Bus coupler Breaker as required. (For Transformer Incomer), 1 Set of 1000 Amps. 415 Volts, FP On Load Cahnge Over Switch with H.R.C. Indication Lights for Load on Servo By-Pass.Both switch gears shall be housed in C.R.C.A. enclosure & complete with inter connects & Cable end boxes. Servo By-Pass Panel-1, As Describe Above
1
-
-
MAIN L.T. PANEL, Incomer :-i) 1 No.1000 Amp FP EDO Air Circuit Breaker (of 50KA Ics Value) with microprossor release for O/L, S/C & E/F protection complete with interlocking with I/C & Bus coupler Breaker as required. LSING Protection.(For Transformer Incomer, 1 No. 630 Amp FP MCCB (of 35KA Ics Value) with microprossor release for O/L, S/C & E/F protection complete with interlocking as required. (For DG Set Incomer-1) LSING Protection, , 1 No. 400 Amp FP MCCB (of 35KA Ics Value) with microprossor release for O/L, S/C & E/F protection complete with interlocking as required. (For DG Set Incomer-2) LSING Protection , Bus-Coupler:- 1 No. 400 Amp FP EDO Air Circuit Breaker (of 50KA Ics Value) as buscoupler with interlocking arrangement with incomers, .Main Bus-Bar:-1 Set of 1250-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). 1 Set of 600-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size)., Metering:- 3 Set of 0-500-V (96 sq.mm) Voltmeter with VSS & protection, MCB 1 Set of 0-1000-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s., 1 Set of 0-630-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s., 1 Set of 0-400-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s. 3 Set of 3 Nos. phase indication lamps (RYB) LED type with protection MCB., 4 Set of 2 Nos. indication lamps ('ON' & 'OFF') LED type with protection MCB.Logic Control::-Interlocking between three incomers and one bus coupler shall be provided by PLC and cost of PLC shall be inclusive in the quoted price including cost of 1 KVA UPS with 20 minutes back up for control circuiting.Control Logic Requirements: - a) When Normal supply of T/F is in "ON" position, then D.G. sets (400 KVA & 250 KVA) in "OFF" condition and Bus Coupler in "ON" position. The Total load should be on Transformer Supply., b) When Normal supply of T/F is in "OFF" position and Bus Coupler in "OFF position, then both D.G. Sets (400 KVA & 250 KVA) in "ON" condition. Total load should be on both D.G. Sets (400 KVA & 250 KVA) c) When Normal supply of T/F is in "OFF" position, then D.G. Set-1 (400 KVA) in "ON" condition and D.G. Set-2 (250 KVA) in "OFF" condition, and Bus Coupler in "ON position. Total load should be on D.G. Sets -1 (400 KVA) d) When Normal supply of T/F is in "OFF" position, then D.G. Set-1 (400 KVA) in "OFF" condition and D.G. Set-2 (250 KVA) in "ON" condition, and Bus Coupler in "ON position. Total load should be on D.G. Sets -2 (250 KVA) e) When normal supply is not available, D.G.Set will start automatically and start feeding the load to all section.f)When Normal supply (S.E.B.) power is restored, in that case also D.G. Sets should start shutting off automatically. g) When Normal supply (S.E.B.) is in healthy condition and feeding to all loads, the generators shall be on stand by mode.Outgoings (Main Bus-Bar):-1 No. 630 Amp FP MCCB of 25 KA with OC, S/C protection, 2 Nos. 315 Amp FP MCCB of 25 KA with OC, S/C protection 3 No. 250 Amp FP MCCB of 25 KA with OC, S/C protection, 5 No. 200 Amp FP MCCB of 25 KA with OC, S/C protection, 4 No. 160 Amp FP MCCB of 25 KA with OC, S/C protection, 3 No. 125 Amp FP MCCB of 25 KA with OC, S/C protection, 1 Nos. 63 Amps. FP MCCB of 16 KA with OC, S/C protection, 2 Nos. 63 Amps. FP MCB of 16 KA , 2 Nos. 40 Amps. FP MCB of 16 KA,Auxiliary Bus-Bar (For Capacitor Bank 210.0 KVAR):- 1 Set of 800-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size)., Metering (Capacitor Bank):- 1 set of 12 stage automatic (Electronic) correction relay with PF meter along with C.T.S. for 210.0 KVAR Capacitor Panel,1 No. Auto / manual selector switch with auto/manual `ON' indication. ,1 set of control contactors / timer / back up HRC fuses for the required interlocking / operation. Outgoings (Capacitor Bank):- 10 Nos. outgoing feeders each comprising of; a) 1 Set of ON/OFF indicating light b) 1 Set of start/stop push button c) 1 No. Auto by-pass selector, 2 sets of 50 KVAR capacitor bank with 125 Amp TP MCB and 25 Amp contactors of capacitor duty.3 sets of 25 KVAR capacitor bank with 63 Amp TP MCB and 25 Amp contactors of capacitor duty.2 sets of 10 KVAR capacitor bank with 32 Amp TP MCB and 25 Amp contactors of capacitor duty. 3 sets of 5 KVAR capacitor bank with 16 Amp TP MCB and 10 Amp contactors of capacitor duty.
1
-
-
Light +Power Panel - A & B (For Circular Block), Incomer 1 Set of 160 Amps. 415 Volts, FP MCCB of 16 KA with LSING fault protection. Bus-Bar:-1 Set of 250-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size).Metering:- 1 Set of 0-500-V (96 sq.mm) Voltmeter with VSS & protection MCB 1 Set of 0-160-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s. 1 Set of 3 Nos. phase indication lamps (RYB) LED type with protection MCB.Outgoings 4 No. 63 Amp FP MCCB of 10 KA with OC, S/C protection 6 Nos. 63 Amps. FP MCB of 10 KA 5 Nos. 40 Amps. FP MCB of 10 KA 2 Nos. 40 Amps. DP MCB of 10 KA
2
-
-
Light +Power Panel - C (For Rectangular Block) Incomer 1 Set of 200 Amps. 415 Volts, FP MCCB of 16 KA with LSING fault protection. Bus-Bar 1 Set of 300-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering 1 Set of 0-500-V (96 sq.mm) Voltmeter with VSS & protection MCB 1 Set of 0-200-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s. 1 Set of 3 Nos. phase indication lamps (RYB) LED type with protection MCB. Outgoings 5 No. 63 Amp FP MCCB of 10 KA with OC, S/C protection 7 Nos. 63 Amps. FP MCB of 10 KA 6 Nos. 40 Amps. FP MCB of 10 KA 4 Nos. 40 Amps. FP MCB of 10 KA
1
-
-
HVAC Panel - A & B (For Circular Block) Incomer 1 Set of 200 Amps. 415 Volts, FP MCCB of 16 KA with LSING fault protection.Bus-Bar 1 Set of 300-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering 1 Set of 0-500-V (96 sq.mm) Voltmeter with VSS & protection MCB 1 Set of 0-200-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s 1 Set of 3 Nos. phase indication lamps (RYB) LED type with protection MCB..Outgoings 4 No. 100 Amp FP MCCB of 10 KA with OC, S/C protection 5 Nos. 63 Amps. FP MCB of 10 KA 4 Nos. 40 Amps. FP MCB of 10 KA 3 Nos. 40 Amps. DP MCB of 10 KA
2
-
-
HVAC Panel - C (For Rectangular Block) Incomer 1 Set of 315 Amps. 415 Volts, FP MCCB of 16 KA with LSING fault protection. Bus-Bar 1 Set of 400-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering 1 Set of 0-500-V (96 sq.mm) Voltmeter with VSS & protection MCB 1 Set of 0-315-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s. 1 Set of 3 Nos. phase indication lamps (RYB) LED type with protection MCB. Outgoings 6 No. 100 Amp FP MCCB of 10 KA with OC, S/C protection 6 Nos. 63 Amps. FP MCB of 10 KA 4 Nos. 40 Amps. FP MCB of 10 KA 4 Nos. 40 Amps. DP MCB of 10 KA
1
-
-
UPS Panel Incomer 1 Set of 100 Amps. 415 Volts, FP MCCB of 25 KA with LSING fault protection. Bus-Bar 1 Set of 150-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering 1 Set of 3 Nos. phase indication lamps (RYB) LED type with protection MCB. Outgoings 5 Nos. 63 Amps. FP MCB of 10 KA 2 Nos. 40 Amps. FP MCB of 10 KA
1
-
-
External Lighitng Feeder Pillar (Outdoor Type) Incomer 1 Set of 63 Amps. 415 Volts, FP MCCB of 25 KA with LSING fault protection. Bus-Bar 1 Set of 100-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering 1 Set of 0-500-V (96 sq.mm) Voltmeter with VSS & protection MCB 1 Set of 0-200-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s. 1 Set of 3 Nos. phase indication lamps (RYB) LED type with protection MCB. Outgoings 4 Nos. 16 Amps. FP MCB of 10 KA 2 Nos. 10 Amps. FP MCB of 10 KA 2 Nos. 16 Amps. DP MCB of 10 KA 2 Nos. 10 Amps. DP MCB of 10 KA
1
-
-
SITC of 250 KVA Silent DG set comprising of 1500.00 RPM, 6 Cylinder coupled to 250 KVA 3 phase , 415V, 50 Hz alternator mounted on a common Base frame along with other accessories i.e., Fuel tank, Manual Control Panel, Battery with leads and acoustic enclosure.DG SETS - REFER DETAILED SPECIFICATIONS FOR DG SETS (General Specifications for Electrical Works, PART -VII DG SETS,2006,CPWD Document.)
1
-
-
SITC of 400 KVA , CPCB II compliant silent DG set, Prime rating, radiator cooled, coupled to 400 KVA electric alternator, with Microprocessor based controller, Residential Silencer, Anti vibration mountings, exhaust flexible connector, Batteries with cables, complete, with
acoustic enclosure and standard Engine safety panel. DG SETS - REFER DETAILED SPECIFICATIONS FOR DG SETS (General Specifications for Electrical Works, PART -VII DG SETS,2006,CPWD Document.)
1
-
-
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-
a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.
b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.
c) Data Monitoring System complete with accessories.
d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.
e) Lightning and surge voltage protection.
f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
80
-
-
SITC of solar water heating system SITC 20 No Flat Plate Collectors, I.S.I. Marked, Inter solar make.2000 LPD Solar Water Heating System (Non-Pressurized) SS-304 – 2mm thickness, Hot Water Tank, duly insulated with Mineral wool/Glass wool 10cm thick, covered with chicken mesh polythene and Aluminum cladding 22 S.W.G.Tank .Tank will have a manhole cover to allow the detachable heat exchanger to be connected inside, manhole cover also to help repair and maintenance. Heat exchanger made out of 1.2mm thick ss-304 pipes using bending technology, with minimum welded joints, of Requisite surface area 0.24 sqm per 100 LPD, detachable, removable type for repair, maintenance. Interconnecting insulated piping (for thermo siphon system) as required at site.GI type with necessary fittings And air vents, insulated with 5cm thick glass wool mineral wool chicken mesh and aluminium cladding 24 S.W.G. Angle Iron frame work of 35×35×5/4 mm angle for supporting the collectors and hot water tank. Grouting of angle work with 1:3:6 concrete minimum 1sq fit contact area with the terrace roof. 6 Elements of 3 KW without wiring, to be screwed on to the hot water tank for electrical backup for cloudy days
2
-
-
Design, supply, Installation, testing & commissioning of the following: 40 KVA/32KW UPS System, 415V, 50Hz. Input and 3Ph.+ N, 50Hz. Output, High performance industrial grade UPS, Advance IGBT rectifier and IGBT PWM Inverter fully digital signal processor (DSP) base with following key features –Ø Input Performance of UPS · “ ZERO Impact on Source (SEB/DG)” · IGBT PWM Rectifier · Current harmonics - 3% (iTHD) · Input PF – 0.99 · Sequential Start up of UPS Systems (smooth change over to DG set) · Wide voltage & frequency Tolerance (320V -480V & 45hz. To 55Hz.) · Normal UPS operation during Input Phase sequence change Ø Output Performance of UPS · IGBT PWM Inverter, Short circuit proof. · More output active power (rated @ 0.9 PF,40KVA = 32KW) · Delta-Star Isolation Transformer · Thermal over rated inverter design, more over load capacities, suitable for industrial loads. (110%, 125% & 150% - 60/10/1 Minute) · Output Voltage 415V +/- 1% (Regulation) · Out put Voltage wave form distortion at 100% non-linear loads (distorting Industrial loads)- 3% (,1% at Linear Loads) · Inbuilt Static bypass and manual maintenance bypass.· On-line battery health monitoring (batteries always ready to work) · Emergency Power Off (EPO), Energy back feed protection. · Communication Options – UPS/ Power status can be monitored through user friendly software. · Interface through – 2 Nos. RS232 Ports, SNMP, Potential Free contacts. Sealed Maintenance Free (SMF) for minimum 15 Minute back up with each 40KVA UPS at full load complete with powder quoted battery racks, interconnecting links.
2
-
-