Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited Tender
View complete overview of Uttarakhand BRIDCUL Tender
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited - BRIDCUL Tender
Security and Emergency Services
Eprocure
Opening Date11 Jun 2024
Closing Date6 Jul 2024
Tender Amount₹ 1,65,59,000
Costs
EMD
₹ 3,31,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BRID3_72222_3Bid Award Id
ViewTender No
914/BRIDCUL/914/24 Dated 06/06/2024Tender Authority
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Providing & fixing 150 mm diameter M.S. Class 'C' diesel pump exhaust pipe includings all fittings, like bends, tees etc. clamps / structural steel supports. The pipe shall be provided with 75mm thick fiberglass insulation & covering the insulation with 500 g polythene sheet giving proper overlaps & sealing the joints with suitable adhesive compound. The pipe shall be provided with 24 gauge aluminium sheet cladding
15
-
-
Supplying, installing, testing and commissioning 0 to 12 Kg/ cm2 ON/OFF pressure switch in delivery line of pump along with control wiring for auto starting and auto stopping of hydrant and jockey pumps.
4
-
-
Supply, fabrication (as per code), installation, testing and commissioning of Pressure vessels 450mm diameter and 1000mm high fabricated from 8-10mm M.S. plate with accessories inside painting with epoxy paint and outside with enamel.
2
-
-
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 for :- 150 mm dia
6
-
-
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 for :- 100 mm dia
2
-
-
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 for :- 80 mm dia
4
-
-
Supply, installation, testing, trial run and commissioning of 1.6mm thick MS door frame 1200x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making 900x600x2100 Recessed type mansoary box (by civil contractor).
8
-
-
Supply, installation, testing, trial run and commissioning of 1.6mm thick M.S. fire hose cabinet (750x750x200) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings & accessories. The box shall have a front glass door with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) - for external and roof hydrant.
7
-
-
Supply, installation, testing, trial run and commissioning of 63mm dia single outlet SS landing valve IS marked with suitable size bolts, nuts, washers and gaskets. Landing valve shall be TAC Approved Make.
15
-
-
Supply, installation, testing, trial run and commissioning of First aid hose reel with 25 mm dia, 30 m long rubber hose, ball valve, piping and GM nozzle
8
-
-
Supply, installation, testing, trial run and commissioning of 63mm reinforced rubber hoses (RRL) with male and female SS coupling, IS marked- 15 m long
30
-
-
Supply, installation, testing, trial run and commissioning of standard short size SS branch pipe with nozzle of 20mm nomnal bor outlet with instaneous type 63 mm dia coupling complete IS marked & TAC approved.
48
-
-
Supply, installation, testing, trial run and commissioning of Fire Axe complete as required
15
-
-
Supply, installation, testing and commissioning ss orifice plates in pipelines to reduce pressure from 8 kg. to 3.5 kg/sq.cm.
7
-
-
Providing, installing, testing & commisioning of fire brigade inlet connection (fire department connection) consisting of 4 Nos. 63 mm dia instantaneous inlet arranged on a 50 mm dia header, 1 No. 150 mm diameter Butterfly valve, 1 No. 150mm dia. Non-return valve and wall mounted box of M.S. construction with glass door to house the above mentioned components.
1
-
-
Providing, installing, testing & commisioning of fire brigade draw out connection (fire department connection) with suction pipe MS class 'C' 100 mm dia. & 100 mm dia. foot valve & steel chain including wall mounted box M.S. construction with glass door to house the above mentioned componenets.
1
-
-
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
300
-
-
Providing and fixing wrapping coating on underground pipe lines with 4mm thick tar cloth.
300
-
-
Constructing masonary chamber 90 x 90 x100 cm. inside with 75 class designation brickwork in cement mortar 1:5 ( 1 cement : 5 fine sand) for sluice valve with CI surface box 100 mm top dia. 180 mm bottom dia. And 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1 :5 :10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size and inside plastering with 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design with FPS bricks
2
-
-
Providing and fixing C.I. double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete ( The tail pieces, tapers etc. if reqd. will be paid separately) 50 mm dia.
4
-
-
Supplying, installing, testing and commissioning 0 to 12 Kg/ cm2 ON/OFF pressure switch in delivery line of pump along with control wiring for auto starting and auto stopping of hydrant and jockey pumps.
2
-
-
providing & fixing of 150 mm dia.pipe Class II
2
-
-
SITC of sprinkers pendent/ upright/side wall sprinklers Omex/Tyco/HD
600
-
-
SITC of flexible pipe for sprinklers 750mm to 1000 mm in length Omex/Tyco/HD
600
-
-
Supply and installation of Butterfly Valves of rating PN 1.6 with mating flanges generally as specified all complete. 150 nominal bore
12
-
-
Supply and installation of Butterfly Valves of rating PN 1.6 with mating flanges generally as specified all complete. 100 nominal bore
6
-
-
Supply and installation of Butterfly Valves of rating PN 1.6 with mating flanges generally as specified all complete. 200 nominal bore
2
-
-
Supply and installation of Butterfly Valves of rating PN 1.6 with mating flanges generally as specified all complete. 50 noninal bore
6
-
-
Supply and installation of Butterfly Valves of rating PN 1.6 with mating flanges generally as specified all complete. 80 nominal bore
6
-
-
Providing and laying cast iron non-return valve of rating PN 1.6 dule ISI marked with flanges generally as specified complete 150 nominal bore
9
-
-
Providing and laying cast iron non-return valve of rating PN 1.6 dule ISI marked with flanges generally as specified complete 100 nominal bore
2
-
-
Providing and laying cast iron non-return valve of rating PN 1.6 dule ISI marked with flanges generally as specified complete 200 nominal bore
1
-
-
Providing and laying cast iron non-return valve of rating PN 1.6 dule ISI marked with flanges generally as specified complete 80 nominal bore
6
-
-
Supply, installation testing & commissioning double flanged 'Y' strainers with M.S. body and SS 40-grade mesh strainer. 150 nominal bore
3
-
-
Supply, installation testing & commissioning double flanged 'Y' strainers with M.S. body and SS 40-grade mesh strainer. 80 nominal bore
2
-
-
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. 200 mm nominal bore (class C)
12
-
-
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. 150 mm nominal bore (class C)
400
-
-
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. 100 mm nominal bore (class C)
300
-
-
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. 80 mm nominal bore (class C)
100
-
-
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. 65 mm nominal bore (class C)
30
-
-
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. 50 mm nominal bore (class C)
100
-
-
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. 40 mm nominal bore (class C)
66
-
-
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. 32 mm nominal bore (class C)
100
-
-
Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as per specificatipns and as required. 25 mm nominal bore (class C)
250
-
-
Providing & Fixing of 4.5 Kg. CO2 Fire Extinguisher. Capacity 4.5 kg
30
-
-
Providing & Fixing of stored pressure Fire Extinguisher ABC powder type (Mono Ammonium Phosphate Powder) Capacity 6 Kg.
30
-
-
Providing & Fixing of stored pressure Fire Extinguisher ABC powder type (Mono Ammonium Phosphate Powder) 50 Kg. Mech. Foam type extinguisher
1
-
-
Providing & Fixing of stored pressure Fire Extinguisher ABC powder type (Mono Ammonium Phosphate Powder) 22.5 Kg. CO2 Fire Extinguisher
2
-
-
COMMON PANEL IN FIRE PUMP HOUSE. Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : Incomings 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A Outgoings ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump And Sprinkler pump 2 nos of 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pumps 2 nos of 100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Diesel Engine Control Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.
1
-
-
Supplying and Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc, with charcoal/ coke and salt as required.
2
-
-
Supplying and laying 25 mm x 5 mm. G.I. strip in 40 mm dia. G.I. Pipe from earth electrode, as required.
40
-
-
Providing & fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required.
150
-
-
Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable as required.
60
-
-
Supplying, fabricating and installing following size of perforated M.S. cable trays, including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including paint 100 mm width X 50 mm depth X 1.6 mm thickness
40
-
-
Supplying, fabricating and installing following size of perforated M.S. cable trays, including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including paint 300 mm width X 50 mm depth X 1.6 mm thickness
30
-
-
Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of sizeUpto 35 sq. mm (clamped with 1mm thick saddle
25
-
-
Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm on surface as required.
175
-
-
Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes. The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals. 3.5 Core 150 sq. mm. Armoured Aluminium cable.
10
-
-
Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes. The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals. 3.5 Core 35 sq. mm. Armoured Aluminium cable.
120
-
-
Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes. The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals. 3.5 Core 16 sq. mm. Armoured Aluminium cable.
120
-
-
Control Cabling (PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays). 2C x 1.5 Sq. mm
60
-
-
SITC of Flow sritches of size 80 mm to 100 mm
8
-
-
INTELLIGENT FIRE ALARM SYSTEM Supplying, installation, testing and commissioning of micro
processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed
maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per
specifications.Ten Loop Panel.
1
-
-
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required
8
-
-
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
560
-
-
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
280
-
-
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required
20
-
-
Supplying, installati on, testing & commissioning of addressable fire control module complete as equired.
10
-
-
Supplying, installation, testing & commissioning of addressable phone control module complete as required.
6
-
-
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
24
-
-
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
24
-
-
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
1
-
-
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
1
-
-
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required
10440
-
-