Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited Tender

View complete overview of Uttarakhand BRIDCUL Tender

Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited - BRIDCUL Tender

Works
Electrical and Electronics
Eprocure
Opening Date11 Jun 2024
Closing Date6 Jul 2024
Tender Amount₹ 1,28,89,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Indoor Units Supply, installation, testing & commissioning of Cassette type/ Ductable type indoor units having galvanized steel plate casing. The unit shall be insulated with sound absorbing, thermal insulation material, Polystyrene / Polyethylene foam. The unit shall be supplied with suitable decorative panel & resin net filter with Mold resistance. The unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting. 4.00 TR Capacity

4

-

-

... More
Indoor Units Supply, installation, testing & commissioning of Cassette type/ Ductable type indoor units having galvanized steel plate casing. The unit shall be insulated with sound absorbing, thermal insulation material, Polystyrene / Polyethylene foam. The unit shall be supplied with suitable decorative panel & resin net filter with Mold resistance. The unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting. 3.19 TR Capacity

18

-

-

... More
Indoor Units Supply, installation, testing & commissioning of Cassette type/ Ductable type indoor units having galvanized steel plate casing. The unit shall be insulated with sound absorbing, thermal insulation material, Polystyrene / Polyethylene foam. The unit shall be supplied with suitable decorative panel & resin net filter with Mold resistance. The unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting. 2.6 TR Capacity

4

-

-

... More
Indoor Units Supply, installation, testing & commissioning of Cassette type/ Ductable type indoor units having galvanized steel plate casing. The unit shall be insulated with sound absorbing, thermal insulation material, Polystyrene / Polyethylene foam. The unit shall be supplied with suitable decorative panel & resin net filter with Mold resistance. The unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting. 2.0 TR Capacity

4

-

-

... More
Indoor Units Supply, installation, testing & commissioning of Cassette type/ Ductable type indoor units having galvanized steel plate casing. The unit shall be insulated with sound absorbing, thermal insulation material, Polystyrene / Polyethylene foam. The unit shall be supplied with suitable decorative panel & resin net filter with Mold resistance. The unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting. 1.6 TR Capacity

4

-

-

... More
Supply of Ductable type indoor units having galvanized steel plate casing. The unit shall be insulated with sound absorbing, thermal insulation material, Polystyrene / Polyethylene foam. The unit shall be supplied with suitable decorative panel & resin net filter with Mold resistance. The unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting. 1.3 TR Ductable Unit (Including corded remote controller)

2

-

-

... More
Supply of Ductable type indoor units having galvanized steel plate casing. The unit shall be insulated with sound absorbing, thermal insulation material, Polystyrene / Polyethylene foam. The unit shall be supplied with suitable decorative panel & resin net filter with Mold resistance. The unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting. 2.6 TR Ductable Unit (Including corded remote controller)

4

-

-

... More
Supply of Ductable type indoor units having galvanized steel plate casing. The unit shall be insulated with sound absorbing, thermal insulation material, Polystyrene / Polyethylene foam. The unit shall be supplied with suitable decorative panel & resin net filter with Mold resistance. The unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting. 3.2 TR Ductable Unit (Including corded remote controller)

1

-

-

... More
Supply, Installation, Testing and Commissioning of Hi wall Type Unit with fittings four speed motor, statically & dynamically balanced fan to give required air flow, coil section with DX coil, outer cabinet, filter with automatic filter cleaning technology along with dust collector to keep filter always clean including all accessories. Cable from indoor unit to socket and headers etc. Which shall be supplied by the OEM of VRV system. complete as required. 1.0 TR Hi-Wall Unit (Including corded remote controller)

2

-

-

... More
Supply, Installation, Testing and Commissioning of Hi wall Type Unit with fittings four speed motor, statically & dynamically balanced fan to give required air flow, coil section with DX coil, outer cabinet, filter with automatic filter cleaning technology along with dust collector to keep filter always clean including all accessories. Cable from indoor unit to socket and headers etc. Which shall be supplied by the OEM of VRV system. complete as required. 1.6 TR Hi-Wall Unit (Including corded remote controller)

2

-

-

... More
Treated Fresh Air Unit (TFA) Supply of factory built Ceiling Suspended type Treated fresh air units complete with DIDW forward curve SA blower section with blower suitable for required static pressure , cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 4/6 rows deep( Dx type), expansion valve, filter section, belt drive package with TEFC drive motor of Eff-1 suitable for 230 ± 10% V, 50Hz, 1 Phase AC supply , Suitable to run with VRV outdoor unit , drain connections, stainless steel (18G) drain pan with PUF insulation. Capacity: 635CFM/4 TR ( Daikin Make )

4

-

-

... More
Supply of Refnet for all indoor units as per layout drawing.

80

-

-

... More
Supply of REIRI , a Smart VRV Manager application that enables control of air conditioners through Smart Devices such as smart phones/tabs from anywher.( Wifi connection,LCD monitor,CPU etc. will be provided by client).

1

-

-

... More
Lifting ,shifting, Installation, testing and commissioning Outdoor/Indoor Unit/pumps as per site condition and approved drawings and manufacturer guidelines. Outdoor Units/pump 40 HP Heat Pump

2

-

-

... More
Lifting ,shifting, Installation, testing and commissioning Outdoor/Indoor Unit/pumps as per site condition and approved drawings and manufacturer guidelines. Outdoor Units/pump 34 HP Heat Pump

2

-

-

... More
Lifting ,shifting, Installation, testing and commissioning Outdoor/Indoor Unit/pumps as per site condition and approved drawings and manufacturer guidelines. Outdoor Units/pump 10 HP Heat Pump(For TFA)

2

-

-

... More
Lifting ,shifting, Installation, testing and commissioning Outdoor/Indoor Unit/pumps as per site condition and approved drawings and manufacturer guidelines. Indoor Cassette type units 4.00 TR Capacity

4

-

-

... More
Lifting ,shifting, Installation, testing and commissioning Outdoor/Indoor Unit/pumps as per site condition and approved drawings and manufacturer guidelines. Indoor Cassette type units 3.19 TR Capacity

18

-

-

... More
Lifting ,shifting, Installation, testing and commissioning Outdoor/Indoor Unit/pumps as per site condition and approved drawings and manufacturer guidelines. Indoor Cassette type units 2.6 TR Capacity

4

-

-

... More
Lifting ,shifting, Installation, testing and commissioning Outdoor/Indoor Unit/pumps as per site condition and approved drawings and manufacturer guidelines. Indoor Cassette type units 2.0 TR Capacity

4

-

-

... More
Lifting ,shifting, Installation, testing and commissioning Outdoor/Indoor Unit/pumps as per site condition and approved drawings and manufacturer guidelines. Indoor Cassette type units 1.6 TR Capacity

4

-

-

... More
Lifting ,shifting, Installation, testing and commissioning of ductable unit as per site condition and approved drawings and manufacturer guidelines 1.3 TR Ductable Unit (Including corded remote controller)

2

-

-

... More
Lifting ,shifting, Installation, testing and commissioning of ductable unit as per site condition and approved drawings and manufacturer guidelines 2.6 TR Ductable Unit (Including corded remote controller)

4

-

-

... More
Lifting ,shifting, Installation, testing and commissioning of ductable unit as per site condition and approved drawings and manufacturer guidelines 3.2 TR Ductable Unit (Including corded remote controller)

2

-

-

... More
Lifting ,shifting, Installation, testing and commissioning of high wall unit as per site condition and approved drawings and manufacturer guidelines 1.0 TR Hi-Wall Unit (Including corded remote controller)

2

-

-

... More
Lifting ,shifting, Installation, testing and commissioning of high wall unit as per site condition and approved drawings and manufacturer guidelines 1.6 TR Hi-Wall Unit (Including corded remote controller)

2

-

-

... More
Lifting ,shifting, Installation, testing and commissioning of TFA unit as per site condition and approved drawings and manufacturer guidelinesCapacity: 635CFM/4 TR ( Daikin Make )

4

-

-

... More
Supply of Refnet for all indoor units as per layout drawing.

70

-

-

... More
ITC of SVM, a Smart VRV Manager application that enables control of air conditioners through Smart Devices such as smart phones/tabs from anywher.( Wifi connection,LCD monitor,CPU etc. will be provided by client).

2

-

-

... More
Supply & Installation of suction & discharge Seamless heavy gauge Copper piping of adequate size duly insulated with 13/19 mm thick Nitrile Rubber Insulation. Refrigeration piping will have to be taken in the piping rack / Support individually connecting to all indoor units for the respective rooms. Pipe work shall include Even necessary connections, tees, reducers, supports, clamps, fittings, valves where ever required will be included.Refrigerant Eco-Friendly- R410a gas for excess Copper Piping for all circuits for entire system. To and Fro shall be measured.

750

-

-

... More
Supply, installation, Testing of PVC Pipe complete with fittings, supports as per specifications and duly insulated with 6 mm thick pipe section of closed cell nitrile rubber. 25 / 32 mm dia

120

-

-

... More
Providing & fixing control cum transmission wiring / Control Cabling of required sizes of copper in suitable conduits between indoor and outdoor unit & indoor unit & its remote controller.

650

-

-

... More
Site Fabricated Rectangular Ducts Supply, installation, balancing and commissioning of Site fabricated at site GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved shop drawings and specifications of following sheet thickness complete as required. 24 G galvanized sheet steel

60

-

-

... More
Site Fabricated Rectangular Ducts Supply, installation, balancing and commissioning of Site fabricated at site GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved shop drawings and specifications of following sheet thickness complete as required. 22 G galvanized sheet steel

40

-

-

... More
Supply, installation, balancing of below 4"/6" dia Al flexible duct including all accessories and hanging arrangement.

100

-

-

... More
Supply, fabrication, Installation and testing of flexible connections constructed of flexible double canvas sleeve with Fire proof, necessary mounting arrangement, flanges, nuts and bolts etc. in accordance with approved shop drawings and as per the specifications

40

-

-

... More
Supply and fixing of acoustic lining of supply air duct and plenum with 10 mm thick open cell nitrile having density of 32 kg/m³, complete as required and as per specifications.

60

-

-

... More
Supply, installation, testing & commissioning of thermal insulation closed cell elastomeric material (nitrile rubber) with aluminium laminated having fire retardant Class “O” properties. complete as required and as per specifications. 13 mm thick

100

-

-

... More
Supplying & fixing of powder coated extruded aluminium Supply Air Grills/Diffusers with aluminium volume control dampers as per specifications.

12

-

-

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills/Diffusers without aluminium volume control dampers as per specifications.

10

-

-

... More
Supply, installation, testing and commissioning of Fresh air louvers with section comprising of powder coated Aluminium louvers with bird screen as required.

2

-

-

... More
Supply,installation,testing of G.I. Volume control dampers complete with linkage, nylon gears and flanges for mounting on branch ducts.

2

-

-

... More
Electrical RCCB with weather proof box Supply, installation, testing ,fixing & commissioning of following rated circuit breaker for VRV ODU units as 40 HP Heat Pump

2

-

-

... More
Electrical RCCB with weather proof box Supply, installation, testing ,fixing & commissioning of following rated circuit breaker for VRV ODU units as 34 HP Heat Pump

2

-

-

... More
Supply, laying, affecting connections and Testing of the following sizes of 1.1 KV armoured PVC insulated copper conductor cables. Cables shall be inclusive of all clamps, saddles, screws, cable glaints, cable terminal thimpals including terminal lugs, insulating tapes, affecting terminal connections to the equipment as per the specifications and as required. (From RCCB to ODU only). Power supply to RCCB shall be provided by you. 4C x 10 Sqmm cable (Copper Armoured )

150

-

-

... More
Supply, laying, affecting connections and Testing of the following sizes of 1.1 KV armoured PVC insulated copper conductor cables. Cables shall be inclusive of all clamps, saddles, screws, cable glaints, cable terminal thimpals including terminal lugs, insulating tapes, affecting terminal connections to the equipment as per the specifications and as required. (From RCCB to ODU only). Power supply to RCCB shall be provided by you. 3C x 1.5 Sqmm cable (Copper Flexible )

300

-

-

... More
Providing & fixing in position the GI Earth wire including providing all fixing accessories & effecting proper connections, 8 SWG GI Earth Wire

150

-

-

... More
SITC of perforated GI Cable tray 300 mm wide for Refrigerant pipes,communication cables.

150

-

-

... More
Underdeck Insulation for Exposed Roof Supply, installation/fixing of Aluminum laminated closed cell elastomeric material (nitrile rubber) sheet having fire retardant Class “O” properties. Density of insulation material shall range between 40-60 Kg/m3. Thermal conductivity (K value) at 40 C mean temperature and Service temperature limit shall be 0.039 W/M.K and –40 C to 105 C respectively. Insulation material shall have excellent ozone resistance properties.25 mm thick

1200

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.