Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited Tender

View complete overview of Uttarakhand BRIDCUL Tender

Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited - BRIDCUL Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date5 Mar 2024
Closing Date11 Mar 2024
Tender Amount₹ 2,10,12,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply installation testing & commisioning of Empty box (IP66) with installation equipment on DIN rails or mounting plates (order separately) with opaque lid fastener for tool operation sealable box walls without knockouts external brackets for wall fixing included, colour: grey, RAL 7035, material: PC (polycarbonate) mounting plate, glands and complete with all required accessories and hardware to complete the job in all resepcts. Built in dimensions W 170 x H 220 x D 96 (Tolerance ± 10%) material: PC (polycarbonate), impact strength IK 09 (10 Joule), in accordance with IEC 62208:2011

6

-

-

... More
Supply installation testing & commisioning of Empty box (IP66) with installation equipment on DIN rails or mounting plates (order separately) with opaque lid fastener for tool operation sealable box walls without knockouts external brackets for wall fixing included, colour: grey, RAL 7035, material: PC (polycarbonate) mounting plate, glands and complete with all required accessories and hardware to complete the job in all resepcts. built in dimensions W 215 x H 320 x D 106 (Tolerance ± 10%) material: PC (polycarbonate), impact strength IK 09 (10 Joule), in accordance with IEC 62208:2011

8

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 225 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
CONDUITS

-

-

-

... More
25 mm dia. ISI marked, PVC conduit

200

-

-

... More
25 mm dia. ISI marked, steel conduit

80

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

8

-

-

... More
Providing and fixing of 25mmx5mm copper strip on surface or in recess for connection etc. as required.

120

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

400

-

-

... More
Supply installation testing and commissioning of 8.0-meter height 140mm dia, C class MS pole, anthracite grey paint, with plate mounting arrangement, plate size 450mm X 450mm X 20mm suitable for bracketless direct lighting fixture installation on pole concorete foundation.

4

-

-

... More
Suppy of LT cable XLPE/PVC insulated 650/1100 volt of following size Aluminium armoured cable as per IS 7098 PART 1. 3.5C x 25 Sq.mm. Aluminum XLPE armored cable

120

-

-

... More
Suppy of following size of LT cable XLPE/PVC insulated 650/1100 volt of following size Copper armoured cable as per IS 7098 PART 1.

-

-

-

... More
4C x 6 Sq.mm. CU XLPE armored cable

100

-

-

... More
4C x 4 Sq.mm. CU XLPE armored cable

80

-

-

... More
3C x 4 Sq.mm. CU XLPE armored cable

200

-

-

... More
3C x 2.5 Sq.mm. CU XLPE armored cable

350

-

-

... More
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland.

-

-

-

... More
4C x 6 Sq.mm. CU XLPE armored cable

20

-

-

... More
4C x 4 Sq.mm. CU XLPE armored cable

20

-

-

... More
3C x 4 Sq.mm. CU XLPE armored cable

40

-

-

... More
3C x 2.5 Sq.mm. CU XLPE armored cable

60

-

-

... More
3.5C x 35 Sq.mm. Aluminum XLPE armored cable

8

-

-

... More
Excavating trenches by mechanical means of required width for pipes,cables,etc,including excavation for socketsand dressing of sides ramming of bottoms for all depth including getting out the excavated soil and then returning the soil as required,in layers not excedding 20 cn in depth including consolidating each deposited layer by ramming within a lead of 50m.

-

-

-

... More
pipes,cables not exceeeding 80mm dia

560

-

-

... More
pipes,cables not exceeeding 80mm dia but not exceeding 300 mm dia

100

-

-

... More
DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.in the existing trench,complete as required

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal)

560

-

-

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

100

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size in existing RCC/DWC/HUME/METAL/overhead/open space pipeas required

-

-

-

... More
Upto 35 sq. mm

1120

-

-

... More
EXTERIOR LIGHT FIXTURES

-

-

-

... More
1000mm ±15% Linear LED 12W ±15%, 800 lumens ±15% - 2700K: Supply installation testing and commissioning of exterior-rated architectural floor/wall mounted IP67, 1000mm ±15% long linear rigid light complete with visor and mounting with 3M VHB/UHB tape or adhesive without any clips/crew/any hardware which shall damage the surface of the temple. The power consumption should be 12 watts ±15%, 800 lumens delivered ±15%, 30 x 70° beam angle with a tolerance of ±15%, CCT-2700K. The housing material should be extruded aluminum with Electrostatically applied polyester powder coating, The luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Fixture shall have silicon glue between the optical cover and the LED chamber and shall have a breather gland to avoid condensation of water. It should have CRI80, and SDCM≤4. Leader cables, jumper cables, and IP68 connectors are included. Minimum IK06. The operating temperature should be of -20°C to 50°C range and storage temperature shall be -40°C to 70°C. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. Manufacturers self-declaration shall be uploaded confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance & ASTM B117 for 500 hours. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

122

-

-

... More
1000mm ±15% Linear LED 15W ±15%, 800 lumens ±15% - 2200K: Supply installation testing and commissioning of exterior-rated architectural floor/wall mounted IP67, 1000mm ±15% long linear light complete with visor and mounting with 3M VHB/UHB tape or adhesive without any clips/crew/any hardware which shall damage the surface of the temple. The power consumption should be 15 watts ±15%, 1100 lumens delivered ±15%, 14 x 50° beam angle with a tolerance of ±15%, CCT-2200K. The housing material should be extruded aluminum with Electrostatically applied polyester powder coating, The luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Fixture shall have silicon glue between the optical cover and the LED chamber and shall have a breather gland to avoid condensation of water. It should have CRI80, and SDCM≤4. Leader cables, jumper cables, and IP68 connectors are included. Minimum IK06. The operating temperature should be of -20°C to 50°C range and storage temperature shall be -40°C to 70°C. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. Manufacturers self-declaration shall be uploaded confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance & ASTM B117 for 500 hours. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

58

-

-

... More
500mm ±15% Linear LED 15W/M ±15%, 800 lumens / M ±15% - 2200K: Supply installation testing and commissioning of exterior-rated architectural floor/wall mounted IP67, 500mm ±15% long linear light complete with visor and mounting with 3M VHB/UHB tape or adhesive without any clips/crew/any hardware which shall damage the surface of the temple. The power consumption should be 15 watts / M ±15%, 1100 lumens /M delivered ±15%, 14 x 50° beam angle with a tolerance of ±15%, CCT-2200K. The housing material should be extruded aluminum with Electrostatically applied polyester powder coating, The luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Fixture shall have silicon glue between the optical cover and the LED chamber and shall have a breather gland to avoid condensation of water. It should have CRI80, and SDCM≤4. Leader cables, jumper cables, and IP68 connectors are included. Minimum IK06. The operating temperature should be of -20°C to 50°C range and storage temperature shall be -40°C to 70°C. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. Manufacturers self-declaration shall be uploaded confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance & ASTM B117 for 500 hours. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

28

-

-

... More
300mm ±15% Linear LED 15W/M ±15%, 800 lumens / M ±15% - 2200K: Supply installation testing and commissioning of exterior-rated architectural floor/wall mounted IP67, 300mm ±15% long linear light complete with visor and mounting with 3M VHB/UHB tape or adhesive without any clips/crew/any hardware which shall damage the surface of the temple. The power consumption should be 15 watts / M ±15%, 1100 lumens /M delivered ±15%, 14 x 50° beam angle with a tolerance of ±15%, CCT-2200K. The housing material should be extruded aluminum with Electrostatically applied polyester powder coating, The luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Fixture shall have silicon glue between the optical cover and the LED chamber and shall have a breather gland to avoid condensation of water. It should have CRI80, and SDCM≤4. Leader cables, jumper cables, and IP68 connectors are included. Minimum IK06. The operating temperature should be of -20°C to 50°C range and storage temperature shall be -40°C to 70°C. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. Manufacturers self-declaration shall be uploaded confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance & ASTM B117 for 500 hours. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

20

-

-

... More
1000mm ±15% Linear LED 12W ±15%, 800 lumens ±15% - 3000K: Supply installation testing and commissioning of exterior-rated architectural floor/wall mounted IP67, 1000mm ±15% long linear light complete with visor and mounting with 3M VHB/UHB tape or adhesive without any clips/crew/any hardware which shall damage the surface of the temple. The power consumption should be 12 watts ±15%, 1100 lumens delivered ±15%, 10 x 30° beam angle with a tolerance of ±15%, CCT-3000K. The housing material should be extruded aluminum with Electrostatically applied polyester powder coating, The luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Fixture shall have silicon glue between the optical cover and the LED chamber and shall have a breather gland to avoid condensation of water. It should have CRI80, and SDCM≤4. Leader cables, jumper cables, and IP68 connectors are included. Minimum IK06. The operating temperature should be of -20°C to 50°C range and storage temperature shall be -40°C to 70°C. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. Manufacturers self-declaration shall be uploaded confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance & ASTM B117 for 500 hours. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

36

-

-

... More
300mm ±15% Linear LED 10W ±15%, 600 lumens ±15% - 3000K: Supply installation testing and commissioning of exterior-rated architectural floor/wall mounted IP67, 300mm ±15% long linear light complete with visor and mounting with 3M VHB/UHB tape or adhesive without any clips/crew/any hardware which shall damage the surface of the temple. The power consumption should be 10 watts ±15%, 700 lumens delivered ±15%, 10 x 30° beam angle with a tolerance of ±15%, CCT-3000K. The housing material should be extruded aluminum with Electrostatically applied polyester powder coating, The luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Fixture shall have silicon glue between the optical cover and the LED chamber and shall have a breather gland to avoid condensation of water. It should have CRI80, and SDCM≤4. Leader cables, jumper cables, and IP68 connectors are included. Minimum IK06. The operating temperature should be of -20°C to 50°C range and storage temperature shall be -40°C to 70°C. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. Manufacturers self-declaration shall be uploaded confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance & ASTM B117 for 500 hours. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

8

-

-

... More
Neon flex washer LED 10W / M ±15%, 800 lumens / M ±15% - 3000K: Supply installation testing and commissioning of exterior-rated architectural floor/wall mounted IP67, Neon flex washer mounting with 3M VHB/UHB tape or adhesive without any clips/crew/any hardware which shall damage the surface of the temple. The power consumption should be 10 watts / M ±15%, 800 lumens / M delivered ±15%, 10 x 30° beam angle with a tolerance of ±15%, CCT-3000K. The housing material should be silicon rubber. It should have CRI80, and SDCM≤4. Leader cables, jumper cables, and IP68 connectors are included. Minimum IK04. The operating temperature should be of -40°C to 45°C range. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

25

-

-

... More
The driver should be remote 24V DC non dimmable (IP67) with PF0.9 & and THD20%. Wattage will be calculated as per site fixture looping

60

-

-

... More
Round flood LED 15W ±15%, 1000 lumens ±15% - 2200K: Supply installation testing and commissioning of exterior-rated architectural floor/wall mounted IP66, round flood light complete with antiglare snoot and mounting with 3M VHB/UHB tape or adhesive without any clips/crew/any hardware which shall damage the surface of the temple. The power consumption should be 15 watts ±15%, 1000 lumens delivered ±15%, 10° beam angle with a tolerance of ±15%, CCT-2200K. The housing material should be die cast aluminum with Electrostatically applied polyester powder coating, The luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. It should have CRI80, and SDCM≤4. The driver should be non integrated DC, and fixture size should not be more than 100mm dia and 200mm length, with PF0.9 & and THD20%. Leader cables, jumper cables, and IP68 connectors are included. Minimum IK06. The operating temperature should be of -20°C to 50°C range and storage temperature shall be -40°C to 70°C. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

16

-

-

... More
Round flood LED 20W ±15%, 1000 lumens ±15% - 3000K: Supply installation testing and commissioning of exterior-rated architectural floor/wall mounted IP66, round flood light complete with antiglare snoot and mounting with the bracket on an 8m high pole. The power consumption should be 20 watts ±15%, 1000 lumens delivered ±15%, 3° beam angle with a tolerance of ±15%, CCT-3000K. The housing material should be die cast aluminum with Electrostatically applied polyester powder coating and the bracket shall be made of cold-rolled iron plate which allows tiltability of ± 90 deg, a locking mechanism to fix and secure the required tilting angle, The luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Fixture shall have a breather gland to avoid condensation of water. It should have CRI80, and SDCM≤4. The driver should be integrated, with PF0.9 & and THD20%. Leader cables, jumper cables, and IP68 connectors are included. Minimum IK06. The operating temperature should be of -20°C to 50°C range and storage temperature shall be -40°C to 70°C. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. Manufacturers self-declaration shall be uploaded confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance & ASTM B117 for 500 hours. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

4

-

-

... More
Round flood LED 24W ±15%, 1700 lumens ±15% - 3000K: Supply installation testing and commissioning of exterior-rated architectural floor/wall mounted IP66, round flood light complete with antiglare snoot and mounting with the bracket on an 8m high pole. The power consumption should be 24 watts ±15%, 1700 lumens delivered ±15%, 30° beam angle with a tolerance of ±15%, CCT-3000K. The housing material should be die cast aluminum with Electrostatically applied polyester powder coating and the bracket shall be made of cold-rolled iron plate which allows tiltability of ± 90 deg, a locking mechanism to fix and secure the required tilting angle, The luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Fixture shall have a breather gland to avoid condensation of water. It should have CRI80, and SDCM≤4. The driver should be integrated, with PF0.9 & and THD20%. Leader cables, jumper cables, and IP68 connectors are included. Minimum IK06. The operating temperature should be of -20°C to 50°C range and storage temperature shall be -40°C to 70°C. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. Manufacturers self-declaration shall be uploaded confirming to compliance of CE Declaration of Conformity, CQC declaration of conformity, RoHS compliance & ASTM B117 for 500 hours. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

14

-

-

... More
Square wall mounted downlight, 6W ±15%, 300 lumens ±15% - 3000K: Supply installation testing and commissioning of exterior-rated architectural floor/wall mounted IP66, square wall-mounted downlight fixture complete with and mounting with 3M VHB/UHB tape or adhesive without any clips/crew/any hardware which shall damage the surface of the temple. The power consumption should be 6 watts ±15%, 300 lumens delivered ±15%, 15° beam angle with a tolerance of ±15%, CCT-3000K. The housing material should be die cast aluminum, a powder-coated finish, The luminaire body color should be similar to the facade color surface. It should have CRI80, and SDCM≤4. The driver should be remote 24V DC non dimmable (IP67) with PF0.9 & and THD20%. Leader cables, jumper cables, and IP68 connectors are included. Minimum IK06. The operating temperature should be of -20°C to 50°C range. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

24

-

-

... More
Round 450mm-600mm high bollard, 10W ±15%, 400 lumens ±15% - 3000K: Supply installation testing and commissioning of exterior-rated architectural floor-mounted IP65, round 450-500mm high bollard fixture complete with mounting on a concrete foundation. The power consumption should be max 10 watts ±15%, 400 lumens delivered ±15%, 360° beam angle with a tolerance of ±15%, CCT-3000K. The housing material should be extruded aluminum, a powder-coated finish, The luminaire body color should be similar to the facade color surface. It should have CRI70, and SDCM≤5. The driver should be integrated 24V DC non dimmable (IP67) with PF0.9 & and THD20%. IP68 connectors are included. Minimum IK08. The operating temperature should be of 0°C to 45°C range. The lifetime of the luminaire (L70) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. The luminaire should be BIS-certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting consultant)

10

-

-

... More
Supply installation testing & commissioning of Two-way Small Format high SPL IP55 rated (as per IEC 60529) all-weather surface-mount loudspeaker. The loudspeaker shall meet the following performance criteria: Frequency Range (-10 dB) of 70 Hz - 18 kHz or better; Nominal Dispersion: 90°H x 60°V (rotatable Horn); Power handling of 1200W peak or more; Sensitivity: 97 dB; Max SPL : 129dB Peak; Nominal impedance of 8 ohms and Integral multi-tap Transformer with selectable tap settings of 10/20/40/80W@70V & 100V. The loudspeaker system shall be comprised of a Powder-coated finish stainless steel grille with Two-part spray polyurea coating Enclosure; Dual 8-inch woofer; Single 2-inch voice coil high-frequency compression driver; U bracket shall be included. Dimensions-225mm X 700mm

9

-

-

... More
Supply installation testing & commissioning of 8 channel class D Power amplifier with a Max Output Power of 8x500W@4 ohms, or bridged mode output power of 4 x 1000W @ 8 ohms/70/100V. 20Hz - 20 KHz, SNR of 101dB and THD + N of 0.4% with built in protection such as Limiters, Temperature, DC, Short Circuit, Peak Current Limiters, Turn on delay etc. Built in DSP for Matrix routing, Speaker equalization, Delays, Array EQs etc with Ethernet Port for Network Control, programming and monitoring.Analog input sensitivity for rated output: 0, +4, +12 and +24 dBu, user selectable; The amplifier front panel shall contain a user interface with a 240 x 64 LCD primary display, with LED indicators for signal present,input clipping, output limiting and fault. Functions accessible from the front-panel interface shall include output configuration, fault logging, mute, input sensitivity selection, output attenuation, EQ on/off per channel and loudspeaker processing preset recall .The Damping factor shall be 1000. The amplifier shall implement Dual Voltage and Current feedback technology to provide power as per the load demand. Shall offer optional Network audio connectivity (Dante ) through expansion slot. This includes suitable racks with PDU and required accessories for the installation of complete system/devices.

1

-

-

... More
Supply installation testing & commissioning of OF12-Channel Mixing Console Max. 6 Mic / 12 Line Inputs (4 mono + 4 stereo). 2 GROUP Buses + 1 Stereo Bus. 2 AUX (incl. FX). D-PRE” mic preamps with an inverted Darlington circuit. 1-Knob compressors. High-grade effects: SPX with 24 programs. 24-bit / 192kHz 2in / 2out USB Audio functions. Works with the iPad (2 or later) through the Apple iPad Camera Connection Kit / Lightning to USB Camera Adapter. Includes Cubase AI DAW software download version. PAD switch on mono inputs. +48V phantom power XLR balanced outputs. Internal universal power supply for worldwide use.

1

-

-

... More
Supply installation testing & commissioning of Dynamic cardioid microphone for speech and vocals with noiseless on/ off switch Cuts through high on-stage levels Clear reproduction with a high presence Consistent sound quality (varying distances, moving off-axis) Handles high sound pressure levels Isolates handling noise, hum compensating coil Excellent feedback rejection.

1

-

-

... More
Supply installation testing & commissioning of 2 core 14 AWG/2.5 Sq mm, Twisted, unshielded Speaker cable with stranded annealed bare copper conductors, Semi-rigid PVC insulation, NEC CL3R, CEC CMG, RoHS compliant.

250

-

-

... More
Supply installation testing & commissioning of 2 core Twisted, shielded balanced Audio and control cable with 22AWG or better 7 strand annealed bare copper conductors, Semi-Rigid PVC insulation, Riser rated PVC jacket. UL 444, UL 13 CMR rated.

20

-

-

... More
Customised Floor Raceway

-

-

-

... More
Supply installation testing and commissioning of Outdoor rated surface-mounted powder-coated aluminum alloy having wall thickness of a minimum of 3MM on all sides, with width limited to 300 MM or less and height limited to 60 MM or less, to house IP66-rated light fixtures as per the BoQ, wiring management and IP68 GEL connectors for internal connections, and to withstand load of 20 MM to 50 MM thick stone on top, for walkover application. It should have proper end caps to cover and protect the wiring. as per the detailed drawing given.

70

-

-

... More
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.

21.07

-

-

... More
REINFORCED CONCRETE & PLAIN CEMENT CONCRETE

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

4.69

-

-

... More
FLOORING WORKS

-

-

-

... More
Regional Stone work (machine cut edges) for wall lining,flooring etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :

-

-

-

... More
50 mm thick fine dressed & chamferd stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone.

-

-

-

... More
Local Hammer dressed stone of size (450x300x50)mm

19.77

-

-

... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of Stone as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make

19.77

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.