Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited Tender
View complete overview of Uttarakhand BRIDCUL Tender
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited - BRIDCUL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Nov 2024
Closing Soon30 Nov 2024
Tender Amount₹ 1,11,98,000
Costs
EMD
₹ 2,24,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BRID3_77678_1Tender No
1967/BRIDCUL/961/24 Dated 06.11.2024Tender Authority
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
3340
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
335
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4485
-
-
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
385
-
-
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
80
-
-
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
15
-
-
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
2 Pair
30
-
-
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
60
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20mm (T.V+Telephone+Network)
60
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6 A switch
8
-
-
3 pin 5/6 A socket outlet
8
-
-
TV antenna socket outlet
4
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
96
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
180
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
86
-
-
Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
76
-
-
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
268
-
-
Supplying and flxing brass batten/angle holder including connection etc. as required.
236
-
-
Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required.
220
-
-
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/ led light fittings of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
222
-
-
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
84
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
-
-
-
Upto 450 mm sweep
46
-
-
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
46
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
12 way , Double door
21
-
-
16 way , Double door
2
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
4 way (4 + 12), Double door
1
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
268
-
-
Triple pole
4
-
-
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
40 amps
21
-
-
63 amps
2
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
63 amps
1
-
-
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
5
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
96
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
20
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
7
-
-
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
7
-
-
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
63
-
-
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
70
-
-
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 6 mm thick copper base plate including holes etc. complete as required.
3
-
-
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
5
-
-
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
155
-
-
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
80
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
Upto 35 sq. mm
65
-
-
Above 35 sq. mm and upto 95 sq. mm
100
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade
as required.
-
-
-
3½ X 50 sq. mm (35mm)
10
-
-
3½ X 70 sq. mm (40mm)
16
-
-
3½ X 120 sq. mm (45mm)
2
-
-
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required
-
-
-
Above 4.5 metre and upto 6.5 metre
10
-
-
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
-
-
-
63 mm dia (OD-63 mm & ID-51 mm nominal)
92
-
-
Supply of AC 230/250 volts, 50 HZ exhaust fans including providing nuts, bolts, mounting frame and other accessories etc. complete
-
-
-
300 mm sweep 900 rpm
46
-
-
Supply of LED Tube fitting ( Batten ) 20 Watts, 1150 mm
207
-
-
Supply of LED Tube fitting ( Batten ) 22 Watts, 1200 mm
15
-
-
Supply and fixing of 3 pole 63 amp MCB 10 KA complete all respect accessories.
7
-
-
Supply of ADP Octagonal Pole single Arm 6 m. height. Compitable for post top range. as approved by Engineer in charge with making connection complete in all respect.
-
-
-
poles with single bracket
8
-
-
Supply & Installation of 70 watt LED Street light Yes Wled Luminaire Light approved by Engineer in charge complete in all respect.
-
-
-
Cat AA (seg.)
8
-
-
Supply of LT XLPE PVC aluminium armoured cable 3.5Cx120 Sq.mm 1100 volt.
100
-
-
Supply of LT XLPE PVC aluminium armoured cable 4Cx6 Sq.mm 1100 volt.
70
-
-
Supply and erection of factory fabricated and wired metal clad dust and vermin proof indoor Cubical panel MCCB complete with the MCB& metering set 1 ph. and instument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprose of Digital type ammeter, voltmeter, selector switches for ammeter and voltmeter, instrument fuses, current transformer etc. The board shall have suitable capacity electroytic aluminium bushbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes. reverse entry boxes in The switches board shall be fabricated with CRCA sheet with a minimum thickness of 2 mm cubicle type.AA
1
-
-
Incoming- 200 Amp MCCB- 1 No.,4p,36 KA
-
-
-
Outgoing-
-
-
-
63 Amp MCB-3 No.,4p, 10 KA
-
-
-
32/40 A MCB -24 No,DP,10 KA
-
-
-
Energy meter 1 ph------24 NO,
-
-
-
Energy meter 3 ph------1 NO,
-
-
-
Change over switch 200 Amp,4p-----1 No
-
-
-
Supply and erection of factory fabricated and wired metal clad dust and vermin proof Cubical out door feeder panel in MCCB complete with the MCB& metering set 1 ph. and instument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprose of Digital type ammeter, voltmeter, selector switches for ammeter and voltmeter, instrument fuses, current transformer etc. The board shall have suitable capacity electroytic aluminium bushbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes. reverse entry boxes in The switches board shall be fabricated with CRCA sheet with a minimum thickness of 2 mm cubicle type.AA
1
-
-
Incoming- 250 Amp MCCB- 1 No.,4p,36 KA
-
-
-
Outgoing-
-
-
-
200 Amp MCCB,4p, 36 KA----1 No
-
-
-
125 Amp MCCB,4p, 30 KA----2 No
-
-
-
40 Amp 4p, cont.with timer set ----1set
-
-
-
Supply and erection of factory fabricated and wired metal clad dust and vermin proof indoor Cubical panel MCCB complete with the MCB& metering set 1 ph. and instument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprose of Digital type ammeter, voltmeter, selector switches for ammeter and voltmeter, instrument fuses, current transformer etc. The board shall have suitable capacity electroytic aluminium bushbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes. reverse entry boxes in The switches board shall be fabricated with CRCA sheet with a minimum thickness of 2 mm cubicle type.AA
1
-
-
Incoming- 125 Amp MCCB- 1 No.,4p,30 KA
-
-
-
Outgoing-
-
-
-
63 Amp MCB-3 No.,4p, 10 KA
-
-
-
32/40 A MCB - 8 No,DP,10 KA
-
-
-
Energy meter 1 ph------8 NO,
-
-
-
Energy meter 3 ph------1 NO,
-
-
-
Change over switch 125 Amp,4p-----1 No
-
-
-
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
(b) Suitable HP Squirrel cage induction motor, TEFC,synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
(d) Suitable cement concrete foundation duly plastered
-
-
-
1620 lpm at 56 m Head
1
-
-
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
-
-
-
450 lpm at 35 m Head
1
-
-
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
-
-
-
INCOMING
400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A
-
-
-
OUTGOING
( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)
200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and
internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.
-
-
-
Jockey Pump
100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Diesel Engine Control Control for diesel engine comprising -
Automatic/Manual selctor switch & 3 attempt startingdevice, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.
1
-
-
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
-
-
-
150 mm. Dia
25
-
-
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
-
-
-
80 mm dia
33
-
-
25 mm dia
10
-
-
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required
-
-
-
Single headed Gunmetal
6
-
-
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required
-
-
-
Single headed Gunmetal
6
-
-
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. onnections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
-
-
-
30 mts long
6
-
-
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia
55
-
-
Supply, Installation, Testing and Commissioning of 30 KWp ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-
a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.(e) Lightning and surge voltage protection.
f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
1
-
-
Supply, Installation, Testining and Commissioning of 8 Passengers not less than 544 kg Elevator (Lift) G+5, 6 stops ,Opening SS finish with SS mirror finish centre panel and all corners in SS finish, centre opening Doors , with SH 300 COP and SH 250 COP controls lift with gear less and machine room less , (Gearless) SS Finished Cabins, Microprocessor Based VVVF drive , 1Mts/ sec. speed,Automatic doors , with ARD Panel , etc. Complete in , fire main switch and emergency Alarm, SH 110 Control Panel and ARD With cabling LED Light on celling complete in all respect.
1
-
-
SITC of Solar Street Light system mentioned below includes LED street Light 30 w , SPV Panel (Solar Panel Wp - 75) ,Lead Acid Battery (Battery-12.8 volt, Ah - 30) , GI Tubular Pole above ground ( 5 M TUB Pole (B)).
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%