Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited Tender

View complete overview of Uttarakhand BRIDCUL Tender

Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited - BRIDCUL Tender

Works
Electrical and Electronics
Eprocure
Opening Date8 Feb 2024
Closing Date22 Feb 2024
Tender Amount₹ 1,02,41,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

230

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

-

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

5810

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 2 X 6 sq. mm + 1 X 4 sq. mm earth wire

100

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.2 X 10 sq. mm + 1 X 6 sq. mm earth wire

-

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.4 X 6 sq. mm + 2 X 4 sq. mm earth wire

100

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire

-

-

-

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as2 Pair

250

-

-

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as 4 Pair

25

-

-

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm

100

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm

100

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch

3

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch

3

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet

3

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet

3

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet

5

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

29

-

-

... More
Supplying and fixing of modular Blanking plate on the existing modular plate & switch box including connections but excluding modular plate etc. as reqd.

3

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm)

15

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)

6

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm)

2

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)

2

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

14

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

29

-

-

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

424

-

-

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.

12

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, LED Fixtures, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

401

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

23

-

-

... More
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

23

-

-

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep

6

-

-

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.

6

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP C

100

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door

4

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door

3

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door

12

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door

2

-

-

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

234

-

-

... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A

3

-

-

... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A

8

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A

7

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A

3

-

-

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

2

-

-

... More
Supplying and fixing 30 A/32A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A/32A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Providing and fixing M.V. danger notice plate of 200x150mm ,made of mild steel at least 2mm thick ,vitreous enameled white on both sides ,and with inscription in single red colour on front side as required.

11

-

-

... More
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required. 150 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required. 100 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays tees with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required. 150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays cross members with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required. 150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete.

10

-

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

23

-

-

... More
Supply, installation, testing and commissioning of following ennealed tinned electric grade copper conductor PVC insulated and PVC sheathed jelly filled armoured telecommunication cable as per specifications. 10 pair armoured riser cable of 0.63 mm dia copper conductor

100

-

-

... More
Supply and installation, testing and commissioning following size KRONE make telephone tag block in lockable 16 gauge sheet medium duity PVC enclosure complete as required. 10 pair Krone type tag block

2

-

-

... More
Supply of 22 Watt LED LUMILINE Plus Metal Construction commercial batten fitting with fuse protection suitable for Polycarbonate diffuser & aluminium heat sink complete suitable for both surface & suspended Mounting, complete in all respect 2200 system lumens PF0.95, THD10%, CRI80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side of existing MS pipe (in case of hanging )complete accessories all respect and as directed by engineer in charge.

389

-

-

... More
Supply of TubeLight 10 watt/1150 lumens suitable for Polycarbonate diffuser & aluminium heat sink complete suitable for Surface Mounting, complete in all respect 1150 system lumens PF0.95, THD10%, CRI80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side of existing MS pipe (in case of hanging )complete accessories all respect and as directed by engineer in charge.,

12

-

-

... More
Supply of LED indoor surface downlighter suitable for general lighting. Luminaire should have polycarbonate cover with diffused optics. The luminaire should have CRI 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification.The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of approx 1650 lumens and maximum system wattage of 10 Watts.power factor 0.95 , THD 10%. he fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.

39

-

-

... More
Supply of Exhaust fan300 mm Air Flow Exhaust Fan metal body with 50 HZ 230 volt ac complete with all respective accessories. 300 mm Air Flow Exhaust Fan

6

-

-

... More
HEXA 10 W - IP66 BULKHEAD

6

-

-

... More
PANEL-1 -Supplying, fixing, testing & commissioning of 415V ,3Phase 50Hz, 4wire system,sheet steel clad,dust & vermin proof cubical & indoor type floor mounted, free standing Main Distribution Board with IP - 42 protection, compartmentalized design and fabricated out of 2mm/1.6mm CRCA sheet steel complete with aluminium Bus Bars, Providing & Fixing of base plate /channel, P/F the following Switchgears,complete with earth Bus Bar throughout the length of the panel,terminal arrangement for incomings/outgoings cables and also outgoing terminations for various sizes of cables,the incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement,adequate size bus duct/cable alley, Sign writing,Painting,Earthing,Numbering,Danger plate etc. Complete as requried,numbering, danger plate etc. complete as required as per specification and drawing. All MCCBs Shall be Ics=100%Icu. Make: Legrand(Adlec) or eqivalent as per approved make list and as direction by engneer in charge. PTTA Panel INCOMER: 1 nos. 400A 415V, Ics=36KA, 4P MCCB with TM release having adjustable O/L, S/C protection. 1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 400/5A. , 1 Set of phase indicating lamp with MCB BUSBAR 630A TPN Bus bar of aluminimum alloy. OUTGOING, 18 nos. 40A, 415V, 4P MCB of 10kA, 4 nos. 40A, 200V, DP MCB of 10kA, 2 nos. 250A, 415V, 4P MCCB of 10kA, 2 nos. 25 A, 415V, 4P MCB of 10kA 4 nos. 32 A, 415V, 4P MCB of 10kA, 2 nos.125 A, 415V, 4P MCCB of 10kA, 2 nos.63 A, 415V, 4P MCCB of 10kA

1

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm

175

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable

175

-

-

... More
Supply and Erecting modular type computer jack RJ 45 with screwless connector approved make with mounting plate and box with wiring connections complete.

7

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

1240

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable

1240

-

-

... More
Supply, installation, testing and commissioning of IP based, 4 MP, FULL HD WDR IR DOME CAMERA - 30 MTRS, colour indoor verifical dome camera, 3.6 MM FIXED LENS, 1/3 ", 4 Mega Pixel PS CMOS Image Sensor, WDR (120 dB), Day/ Night (ICR), IR Range of 30 Mtrs, IP67 and all ancillary equipments and all accessories.

9

-

-

... More
Supply, installation, testing and commissioning of IP based, 4 MP, FULL HD WDR IR bullet CAMERA - 40 MTRS, colour indoor verifical dome camera, 3.6 MM FIXED LENS, 1/3 ", 4 Mega Pixel PS CMOS Image Sensor, WDR (120 dB), Day/ Night (ICR), IR Range of 40 Mtrs, IP67 and all ancillary equipments and all accessories.

25

-

-

... More
Supply, Installation, Testing and Commisioning of 64 CHANNEL NETWORK VIDEO RECORDER, H.264/MJPEG dual codec decoding,Max 256 Mbps incoming bandwidth, HDMI/ VGA simulation video output, support 8 SATA HDD's upto 32 TB, 1 ESATA up to 16 TB, supports multi brand network cameras. Each NVR shall have a storage capacity so as to record a backup for 15 days at 4 CIF @ 25FPS.NVR should have system expandibility feature of at least 20% of current requirement, redundant fan and power supplies, outputs TCPIP network feature & server software monitor outputs. The NVR should be networkable via IP protocol & should be able to connect to a web based system for remote viewing via web system. Vendor should submit the storage / HDD Calculation.

1

-

-

... More
Supply, Installation, Testing and commisioning of 32" inches LCD monitor

2

-

-

... More
Supply, Installation, Testing and commisioning of POE SWITVH 16 PORT

4

-

-

... More
Supplying, installation, testing & commissioning of manual call boxes of MS construction Insurface/recess with stainless steel chain & ammer assembly complete with glass and push button etc. as required.

6

-

-

... More
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.

6

-

-

... More
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required 10 Zone

1

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

8

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

8

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

80

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

30

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

80

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

80

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

8

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

8

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

300

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

300

-

-

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

20

-

-

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

40

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm

175

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm

30

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm

125

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm

30

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/existing open trence/as required. Upto 35 sq. mm

80

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/existing open trence/as required. Above 95 sq. mm and upto 185 sq. mm

20

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/existing open trence/as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

600

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/existing open trence/as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

80

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 3½ X 95 sq. mm (38mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 3½ X 120 sq. mm (45mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 3½ X 185 sq. mm (45mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 4 X 10 sq. mm (25mm)

6

-

-

... More
Erection of metallic/octagonal pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 4.5 metre and upto 6.5 metre

10

-

-

... More
Providing and making steel pole collar with cement concrete (1cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted)

4

-

-

... More
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia

6

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 100 mm dia

10

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 150 mm dia

10

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)

20

-

-

... More
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications.2CX6 SQMM AL ARMOURD CABLE

350

-

-

... More
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications.2CX10 SQMM AL ARMOURD CABLE

50

-

-

... More
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 4CX 6 SQMM AL ARMOURD CABLE

600

-

-

... More
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications.4CX10 SQMM AL ARMOURD CABLE

100

-

-

... More
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications.4CX16 SQMM AL ARMOURD CABLE

50

-

-

... More
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3.5CX150 SQMM AL ARMOURD CABLE

150

-

-

... More
Supply of following sizes of XLPE insulated Copper Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 2CX 2.5 SQMM Cu ARMOURD CABLE

80

-

-

... More
Supply of following sizes of XLPE insulated Copper Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 2CX 4 SQMM Cu ARMOURD CABLE

800

-

-

... More
Supply of following sizes of XLPE insulated Copper Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 4CX 4 SQMM Cu ARMOURD CABLE

100

-

-

... More
Supply, installation, testing & commissioning of 9 Watt LED Spike Light Fitting

10

-

-

... More
Supply, installation, testing & commissioning of 8 Watt LED BOLLARD Light Fitting

12

-

-

... More
Supply, installation, testing & commissioning of 70 Watt LED STREET Light Fitting

12

-

-

... More
Supply of 5.0 Mtr Height Galvanized Iron Octagonal Poles having uniformly tapered polygonal shape throughout the length with straightLongitudinal welding in a single shaft. There shall not be any circumferential welding. Dimensions:Top Dia.: 70mm, Bottom Dia.: 130mm, Thickness 3mm &Base plate 200*200*12 mm. Dimension of Foundation Bolts - Length 600mm, Dia. 24mm &04 Nos. Bolts manufactured from special steel along with nuts, washer, anchor plates & Templates. SingleArm of 0.5 Mtr. Shall be provided along with

14

-

-

... More
Supplying & laying 1.1 kv grade ISI marked synthetic rubber mats as per specifications of chief electrical inspectorate.

8

-

-

... More
Supplying & fixing of shock treatment chart printed in hindi and english fitted in wooden frame and glass at front side and hard board at back side.

8

-

-

... More
Supplying & fixing in position 1.1 kv rubber hand gloves.

4

-

-

... More
Supplying of first aid box as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS : 2217 - 1963.

3

-

-

... More
Supplying of basic Electrical and mechanical maintenance tool kit as per direction of engineer In charge.

1

-

-

... More
PACKAGE SUB-STATION Supply, unloading, shifting, erection, testing & commissioning of Package type sub-stations (PSS) as per Specifications, complete with 11 KV, 16kA Switchgears, Transformers and 1100V switchgear as per specification & as described below:(Note:-The civil RCC foundation for PSS shall be in the scope of Civil contractor but approval of related drawings & co-ordination is part of the electrical works/item). CSS Outdoor type package substation with facility for internal lighting, earthing, padlocks etc. Connection between RMU & transformer will be by 3 nos. 1Cx185 sq.mm. XLPE cable/Busbar and connections from transformer to LT switchgear will be by busbar connections. Cable termination kits for RMU are in our scope of supply (within enclosure). HT Panel (RMU UNIT) :- 1 No. 11KV, 400A 21KA/3 Sec Indoor type, Non-extensible Manual Operated SF6 gas insulated Ring Main Unit with 2Nos. load Switches 1No. Vacuum Circuit breaker enclosed in a stainless steel tank with self powered microprocessor bases numerical relay and dedicated CT’s for protection of Transformer. ·         IDMT RELAY for Circuit Breakers – Self Powered (Merlin Gerin type VIP35 or equ ivalent). . The Ring Switches and Tee-Off Circuit Breaker are provided with Integrated Earthing Switches with Making Capacity. ·         Neon cable indicator for ring switches & circuit breaker. ·         Integral earthing facility for ring switches. ·         Shunt trip coil rated for 230V AC. ·         Trip push button for T-off circuit breaker. ·         SF6 Gas pressure indicator. . Padlocking facility Transformer : 1 No. 200 KVA, 11KV/433V hermetically sealed corrugated tank type design off circuit oil filled transformer with off load tap changer, tapping range +5% to -5% in step of 2.5% each step complete with standard fittings & accessories confirming to Latest IS standards LT DETAILS (AS PER SLD) 1 * 400 A, 4 Pole,50 KA, MCCB with the following :- METERING & CONTROLS - breaker ON/OFF/TRIP indicating lamps with control fuses. - Ammeter complete with CT and selector switches as required. - Voltmeter complete with selector switches as required. - Electronic energy meter of required rating complete

1

-

-

... More
Supply & laying of following sizes of XLPE Aluminum Armoured 11 KV grade HT cables conforming to relevant IS code and technical specifications. 3 X95sq mm.

40

-

-

... More
Supplying & making of INDOOR cable end terminations with HEAT SHRINKABLE JOINTING KIT with all accessories including lugs suitable for following sizes of 3 core, XLPE Al conductor cable of 11 KV grade as required. 3 X95sq mm.

3

-

-

... More
Supplying & making of OUTDOOR cable end terminations with HEAT SHRINKABLE JOINTING KIT with all accessories including lugs suitable for following sizes of 3 core, XLPE Al conductor cable of 11 KV grade as required. 3 X95sq mm.

2

-

-

... More
Supply, installation, testing and commissioning of SEB approved 11 kV Metering Panel with Electronic tri vector meter of SEB approved make, complete in all respects including CT & PT and test terminals etc.

1

-

-

... More
Supply, installation, testing and commissioning of 400 A, 11 kV, TP, vertically mounted, off load gang operated switch with padlock and operating handle including drop out fuse assembly and Lightning Arrestor complete in all respects including insulators, MS supports, channels etc. as required, and including DP structure of beams and channels as required.

1

-

-

... More
5KVA/4.5KW UPS System, 415V, 50Hz. Input and 3Ph.+ N, 50Hz. Output, High performance industrial grade UPS, Advance IGBT rectifier and IGBT PWM Inverter fully digital signal processor (DSP) base with following key features –MODULAR TYPE UPS WORKING IN PARALLEL Ø      Input Performance of UPS ·    “ ZERO Impact on Source (SEB/DG)” ·    IGBT PWM Rectifier·    Current harmonics - 3% (iTHD) ·    Input PF – 0.99 ·    Sequential Start up of UPS Systems (smooth change over to DG set) ·    Wide voltage & frequency Tolerance (320V -480V & 45hz. To 55Hz.) ·    Normal UPS operation during Input Phase sequence change Ø     Output Performance of UPS ·    IGBT PWM Inverter, Short circuit proof. ·    More output active power (rated @ 0.9 PF,5KVA = 4.5KW) ·    Delta-Star Isolation Transformer ·    Thermal over rated inverter design, more over load capacities, suitable for industrial loads. (110%, 125% & 150% - 60/10/1 Minute) ·    Output Voltage 415V +/- 1% (Regulation)·    Out put Voltage wave form distortion at 100% non-linear loads (distorting Industrial loads)- 3% (,1% at Linear Loads) ·    Inbuilt Static bypass and manual maintenance bypass.     On-line battery health monitoring (batteries always ready to work)·    Emergency Power Off (EPO), Energy back feed protection.·    Communication Options – UPS/ Power status can be monitored through user friendly software. ·    Interface through – 2 Nos. RS232 Ports, SNMP, Potential Free contacts.Sealed Maintenance Free (SMF) for minimum 30 Minute back up with each 5KVA UPS at full load complete with powder quoted battery racks, interconnecting links.

1

-

-

... More
Supplying and Installation of a Machine room Passenger Lift for 15 Passenger . The Lift to be designed for 05 Stops with on Automatic rescue device. The cost to be include all works (Except Civil & Construction) Electrical Supply for LIft Installation and handling over with a comprehensive on site warranty of one year from the date of handing over. The Lift interiors to be of brushed SS Finish and the cost of the include all items like Grab bar, Light etc.Complete.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.