Bharat Sanchar Nigam Limited Tender
View complete overview of Uttarakhand BSNL Tender
Bharat Sanchar Nigam Limited - BSNL Tender
Telecommunication Services
Eprocure
Opening Date28 Mar 2024
Closing Date6 Apr 2024
Tender Amount₹ 4,43,661
Costs
EMD
₹ 8,873Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_192533_1Bid Award Id
ViewTender No
76/EE(E)/BSNL/ED/DDN/23-24Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://https://www.bsnl.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Rate Contract for Call basis Servicing and repairing of ACs units of various exchanges BTSs in BA Dehradun
BOQ Items
... More
In rural Hill area in Dehradun BA
3
-
-
... More
General Servicing of all type & capacity WAC /SAC /HSHF /Water cooler units at site of different make and model I/c removing from existing position if reqd, dismantling of faulty parts, cleaning the air filter, cleaning the condenser and evaporator coil with help of water pressure spray gun , lubrication of moving parts, complete checking, testing and minor faults rectification i/c replacement of knobs/ wiring kit (if required), setting of thermostat, preparing report including tightness of all electrical connections from SP MCB in DB to DP MCB/Plug & socket to stablizer to AC unit etc as reqd.
-
-
-
... More
In Dehradun City
15
-
-
... More
In rural area in Dehradun up to 60 Km
5
-
-
... More
In rural Hill area in Dehradun BA
3
-
-
... More
Charging of Refrigerant gas R-22 /R-32/410 up to specified pressure(as per manufacturer's recommendation) in following capacity AC units and pressure testing by nitrogen, vaccumisation for 2 hours, purging with gas and testing commissioning of the AC unit etc. as reqd. Note: One job consists of charging of Gas in one compressor i.e.. One complete air conditioning circuit only.
-
-
-
... More
1.5 TR
5
-
-
... More
2.0 TR
3
-
-
... More
Replacement of the following items/accessories in the existing WAC/SP AC/water cooler Units of all makes in place of faulty/unserviceable parts i/c dismantling of the faulty, fixing the new item and testing, connection etc. complete as reqd.
-
-
-
... More
120-140 MFD Starting Capacitor aluminum case
5
-
-
... More
40/50 MFD Running Capacitor aluminum case
5
-
-
... More
4MFD Fan Motor Capacitor aluminum case
5
-
-
... More
WAC Blower /WAC/condenser fan blade
5
-
-
... More
Starting relay
5
-
-
... More
PCB for Split AC 1.5 TR/2TR
5
-
-
... More
PCB for inverter type Split AC Indoor Unit
3
-
-
... More
PCB for inverter type Split AC 1.5 TR-For Out door Unit
3
-
-
... More
S/F of Blower/Condenser fan motor for 1.5 / 2 TR Window/Split A.C/water cooler unit in lieu of unservisible motor i/c connection etc as required.
3
-
-
... More
Provision of Top up of R-22/R-32 /410 gas in existing all type Window A.C /Split A.C/ units, flushing, testing etc. as required.
5
-
-
... More
Rewinding of existing all type Blower/condenser fan motor for 1.5/2 TR Window/Split A.C unit/water cooler i/c replacement of bush i/c oiling ,greasng etc as required
3
-
-
... More
P/F 12mm thick Exterior grade particle board for AC Unit for support i/c fixing the same with screw ,complete etc. as reqd.
2
-
-
... More
Replacement of the 1.5 TR rotary type compressor I/c dismantling of the existing compressor from site, to and fro transportation charges and I/T/C of compressor in existing WAC / Split AC etc complete as required.
Note: The agency has to provide one year guarantee for every replaced compressor along with Test Certificate / Invoice of Purchase from authorized dealer, Faulty Compressor shall be the property of contractor.
3
-
-
... More
Replacement of the 1.5 TR Reciprocating type compressor I/c dismantling of the existing compressor from site, to and fro transportation charges and I/T/C of compressor in existing WAC / Split AC etc complete as required.
Note: The agency has to provide one year guarantee for every replaced compressor along with Test Certificate / Invoice of Purchase from authorized dealer, Faulty Compressor shall be the property of contractor.
3
-
-
... More
S/F of following item in exsiting MV panel /MCB DB /free cooling i/c dismentling of faulty unit (if reqd ) i/c ,connections, testing etc comp as reqd.
-
-
-
... More
5 A to 32 A , 240/415 V, 10 kA, "C" curve, SP MCB
3
-
-
... More
5 A to 32 A , 240/415 V, 10 kA, "C" curve, TP MCB
3
-
-
... More
5 A Plug Top
5
-
-
... More
15 A Plug Top
5
-
-
... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
3
-
-
... More
Replacement of following faulty accessories in exsiting Timer/ controllor unit , connections, testing etc comp as reqd.(Make--Legrand or similar superior make)
-
-
-
... More
2 Pole Contactor 25 A ,230V (Make-L&T- 25 A-MNX)
5
-
-
... More
Supplying & fixing Analog daily time switch of 16 A Capacity ,One C/O ,Din /Base mounting , 24 hour Programmable operation for Used for Automatic switching ON/OFF for Electric street lights suitable to work on 230 V AC Supply i/c connection etc Timer - (Make-L&T /GIC or similar superior make)
3
-
-
... More
Installation, Testing & Commissioning of the following type Split type AC unit at a specified location as per direction of Engg-In-charge by mounting/fitting Indoor and Outdoor units , making opening in wall behind indoor unit , laying and fixing of both liquid and hot gas lines , inter connecting wiring for both indoor outdoor units up to 3 mtrs length and ,interconnecting the indoor unit and outdoor unit with refrigerant line, insulating the refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle , Leak testing entire system ,vacuemising the system ,charging of Refrigerant gas in the unit ,making power supply connections from the power point,and making good the damages etc.as required.
-
-
-
... More
1.5/2 TR Split AC unit
5
-
-
... More
2x1.5/2 TR HSHF AC unit
3
-
-
... More
Pdg and Fixing of following size additional following size same as supplied by Split AC manufacturer refrigerant copper piping with 3x2.5 sq.mm. PVC Insulated PVC Sheathed copper cable i/c covering of Copper Pipe with polystyrene insulation i/c cutting ,brazing ,jointing,bends, sockets etc as reqd. ( Note- Combined Length shall be measured )
-
-
-
... More
1/4"&5/8"
20
-
-
... More
3/8"&5/8"
5
-
-
... More
S/F of 50 mm dia PVC pipe for wall crossing of refrigerant and drain pipe of split AC units etc as reqd.
3
-
-
... More
S/F of 19 mm dia PVC Wire braded pipe for drain water of SPAC i/c fixing on wall surface with suitable MS shaddle etc.as te reqd.
20
-
-
... More
S/F Powder coated MS stand, for wall /Floor mounting of outdoor unit of Split AC i/c fixin gthe same on wall with suitable fastner etc as reqd
3
-
-
... More
Supplying and fixing of following size of white colour flexible copper cable on surface/ recess, suitable for work on 230 volt, 50 HZ AC supply i/c connection etc as reqd (Note--Cables have joints shall be replaced to avoid fire hazard)
-
-
-
... More
3x1.5 sq mm
10
-
-
... More
3x2.5 sq mm
20
-
-
... More
Insulating the existing laid refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle etc as reqd
10
-
-
... More
Dismantling of the existing split /window type AC Unit complete with indoor unit,outdoor unit stand, refrigerant piping,drain pipe,shifting the dismaltled items to a safe place in exchange premises and handing over to the incharge,packing of SPAC wall hole ,making good the damage etc as reqd .
10
-
-
... More
Dismantling of the existing 2x1.5/2 TR HSHF type Split AC Unit complete with indoor unit,outdoor unit stand, refrigerant piping,drain pipe,shifting the dismaltled items to other room in same exchange premises ,packing of SPAC wall hole ,making good the damage etc as reqd .
3
-
-
... More
Installation of existing 1.5/2 TR Reciprocating /rotary type comressor in the all type AC units i/c connecting with existing refrigerent pipeline i/c vacuemising , nitrogen pressure testing ,etc as reqd
3
-
-
... More
Closing of existing window in AC opening area to prevent AC leakage/theft by Single brick masnoary i/c plastering with cement mortar , finishing etc complete as reqd as reqd.
1
-
-
... More
Transportation of Split /Window AC units/water cooler with all acessories like indoor ,outdoor unit ,copper pipe ,drain pipe ,partical board ,stand from One TE building to various TE /BTS sites in BA Dehradun i/c. loading,unloading etc. as reqd.
5
-
-
... More
SITC of 400 mm sweep oscillating type wall mounted fan with three speed control regulator having 1350 RPM speed ,70 M3/min air delivery suitable for working on 230 V ,50 Hz single phase AC supply & i/c fixing on wall with suitable fastner , connection etc. complete as required (Crompton/Bajaj/orient/polar/Almonard/USHA)
3
-
-
... More
SITC of 450 mm sweep oscillating type wall mounted fan with three speed control regulator having metalic body and metal blade ,1325 RPM speed , 6030 m3/Hour Air Displacement ,suitable for working on 230 V 50 Hz single phase AC supply & i/c fixing on wall with suitable fastner , connection etc. complete as required (Crompton/Bajaj/orient/polar/Almonard/USHA)(Conference Hall )
3
-
-
... More
S/F of following size metallic body exhaust fan with front guard ,1350 rpm ,Air delivery 550 CMH suitable for operation on 230 Volts ,single phase 50 Hz AC supply complete etc as reqd (Make -( Bajaj/Polar /USHA /crompton /havells /orient )
-
-
-
... More
300mm
3
-
-
... More
Supplying & fixing of powder coated Free Cooling unit made out of 18 gauge M.S.Sheet box with locking door in front & jali in back side i/c Supplying & fixing 300 mm sweep Heavy Duty Exhaust Fan 1400 rpm suitable for 230 V 50 HZ AC Supply i/c making opening in brick wall / window for fixing of unit, connection , testing etc (Exhaust Fan Make-- Crompton / Havells/ Bajaj or similar superior make )
-
-
-
... More
Out door unit ( For exhaust of hot Air)
3
-
-
... More
S/f timer unit constituting of 01 no. digital type thermostat/ Temp controller with LED display & sensor with lead and 01 no. Analog Time Switch /Electronic timer (1 second to 10 hrs ) in suitable size MS box with hinged door, connection etc. as required. (Timer Make-BCH/L&T/GIC-J648B1 & Analog Time Switch make - SELEC - TC513/TC533BX or similar superior make) Note-- Timer will run Exhaust fan for 2 hrs and kept in off position for 15 minutes
3
-
-
Evaluation Notes How It Works ?