Yamuna Expressway Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Yamuna Expressway Industrial Development Authority - YEIDA Tender
Civil And Construction
Building Construction
Eprocure
Opening Date19 Feb 2024
Closing DateCancelled
Tender Amount₹ 29,02,423
Costs
EMD
₹ 58,500Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_YEIDA_898468_4Bid Award Id
ViewTender No
YEA/GM(PROJECT)/2024/884 DT-15/02/2024Tender Authority
Yamuna Expressway Industrial Development Authority ViewPurchaser Address
-Website
http://etender.up.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
B/W with bricks of class 150 in Super structure in CM 1:4 (Based on UP PWD SOR 2020) Cement mortar 1:4 ( 1cement :4Coarse sand)
44.52
232839
5230
M-150 brick work in 1:4 one cement and four course sand 2.20 F.M. mortar superstructure but for walls of half brick thick including supply of all material, labour, T&P etc. required for proper completion of the work. (UPPWD/SOR-2020/305(a)+310A
1.96
10642
5430
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level
16.68
130932
7849.65
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level
33.94
291614
8592.05
Centring and shuttering including strutting, propping etc. and removal of form for : foundation footings, base of column
39.42
7160
181.65
Centring and shuttering including strutting, propping etc. and removal of form for : lintels, beams, plinth beam, grinder
128.29
41245
321.5
Centring and shuttering including strutting, propping etc. and removal of form for : column, pillers, piers
63
26888
426.8
Centring and shuttering including strutting, propping etc. and removal of form for : suspended floors, roofs, landings
123.24
47613
386.35
Supply and laying of earth work in rough excavation banking excavted earth in layers nt exceeding 20cm in depth
90
20079
223.1
Thermo-Mechanically Treated bars of grade Fe-500D or more./Cold twisted bars. (DAR/5.22.6/Based on UPPWD/SOR-2020))
7617.34
732788
96.2
12mm cement plaster of mix: 1:4 (1 cement : 4 coarse sand) BASED on UP PWD SOR 2020
313.9
51730
164.8
6mm cement plaster of mix: 1:3 (1 cement : 4 coarse sand) BASED on UP PWD SOR 2020
97.75
12971
132.7
15mm cement plaster of mix: 1:6 (1 cement : 4 coarse sand) BASED on UP PWD SOR 2020
323.18
61840
191.35
Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
323.18
38070
117.8
Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade
411.66
28404
69
Painting with synthetic enemel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
53.04
4092
77.15
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 90mm dia
9
2032
225.8
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size aggregate
97.74
40415
413.5
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
928.2
93841
101.1
Providing and fixing water closet squatting pan (Indian type W.C. pan with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
2
7416
3708.25
Providing and fixing wash basin with C.l. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.
2
4472
2236.45
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 15 mm nominal outer dia .Pipes.
30
8037
267.9
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs C) After two days of proper curing applying a second coat of cement slurry using 2.75kg! sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre doth of approved quality in top layer of plaster and finally finishing the surface with trowe’ with neat cement suvr an making pattern ot 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge:
110.09
117592
1068.15
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suttable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
500
3825
7.65
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand including finishing the top smooth
62.4
31084
498.15
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600mm (DAR/11.41.2/Based on UPPWD/SOR-2020))
116.69
137384
1177.35
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DAR/8.31/Based on UPPWD/SOR-2020))
114.45
120481
1052.7
Providing and fixing brass bib cock of approved quality: 15 mm nominal bore (DAR/18.15.1/Based on UPPWD/SOR-2020))
2
525
262.65
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 25 mm nominal bore (DAR/18.17.1/Based on UPPWD/SOR-2020)
2
863
431.5
Providing and fixing nahani trap 75x100mm including all complete.
2
662
331.05
20 mm cement plaster of mix 1:4 (1cement : 4 coarse sand)
4.36
1088
249.7
Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle iron, 3mm M.S. gusset plates at the junction and corners 25mm dia pulley, 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer.
10.4
34892
3355.05
Renewing panes of glass in door, window & ventilators or fixing in the new work with 3mm thick glass panes fixed with brads & putty includung supply of all material , labour , tools & plants required for proper completion of work
6.83
3278
480
Prroviding and fixing ISI Mark 3 layer prelaminated particle board conforming to grade 2 type-III of IS-12823/20B laminated with 0.6-0.8 mm thick laminate conforming to IS-2046/1995 and balancing lamination of 0.5 mm thick on the back side (size 700*750*430) including all complete
2
14932
7466.1
supply of work SB collection office/visitor chain with sheat DXWXH 400*400*450 mm padded with polyurithane foam complete
24
118982
4957.6
supply wook at site SB collection executive table of 3 layer Prelaminated particle board (wood product) of grade 2 type 2 of IS-12823/latest 1830 mm 950 mm 750mm including all complete
6
185059
30843.2
Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete.
16.13
19356
1200
providing and fixing glass strip in joint of terazo/ cement concrete floors 40mm wide and 4mm thick (DAR/11.13.1 Based on UPPWD SOR 2020)
120
4566
38.05
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
582.75
61713
105.9
Wiring point for light in 1.5 sq. mm. PVC insulated single core copper conductor cable (in PVC conduit with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside conduit.) and 5 Amp.flush type switch & ceiling rose/angle/batten holder fixed with 3mm thick phenolic laminate backalite sheet with brass machine screws and cup washers mounted over existing M.S. switch board box/ junction box with supply of all material, labour & T&P etc. required for proper completion of the work complete in all respect, as directed by Engineer in charge PWD-2018 PS No-174C
26
10140
390
Supply and Wiring of submains with 2 nos. of 2.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy duty (2 mm thick) PVC conduit with 2 nos 2.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit complete in all respect, as directed by Engineer in charge PWD-2018 PS No-261C
80
17360
217
Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. complete in all respect, as directed by Engineer in charge .PWD-2018 PS No-1139A
15
9375
625
S&F surface/flush mounting 8 ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. PWD-2018 PS -1024A
1
1900
1900
S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve complete in all respect, as directed by Engineer in charge.PWD-2018 PS -1002 CAT-A
4
1040
260
S&F of 40 Amp. DP MCB (10 KA) C Curve complete in all respect, as directed by Engineer in charge. PWD-2018 PS No-1010 Cat-A
1
1180
1180
Installing, testing and comissioning of ceiling fan including wiring the door roads of standard length (upto 30m) width 1.5 FRCS PVC insulated, copper conductor, single core cable, including providing & fixing phenolic laminated sheet cover on the fan box etc is required
12
1494
124.54