Yamuna Expressway Industrial Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Yamuna Expressway Industrial Development Authority - YEIDA Tender

Works
Civil And Construction
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Nov 2024
Closing Date24 Dec 2024
Tender Amount₹ 1,55,26,079 
Notes
Download

Costs

Summary

S/i/t/c Of Cricket Stadium Lights Tower Rabupura Yea.e M -02

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
: a) Can Survive input Voltage Stress of 320V for 48 hours, b) Cut Off Auto Shutdown at ≥ 325V and Auto Recovery at 300 - 315V, c) Can Survive input Voltage Stress of 440V for 8 hours, d) Can Survive input Voltage Stress of 100V for 48 hours & e) inbuilt surge protection of 4KV In-built in the driver. The luminaire shall employ external SPD of 10KV housed inside a box. The luminaire driver &it’s SPD shall be of the same make/manufacturer/Lighting company as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, electrical & electronics tests , Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports along with technical bids: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, IK Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver. Equivalent in Signify (Philips). . LED Flood Light 60000lumens as per the directions of the Engineer-in-charge Analysis of Rates

112

42000

4704000

... More
30Mtr height suitable for Sports application Supply, Installation, testing & commissioning of 30m Hot dip galvanized, polygonal high masts with fixed head frame/cross arms suitable for mounting up to 28 nos. of minimum 465w LED lighting fixtures complete with all accessories as per specification and to obtain an average vertical/horizontal illumination. The height of the mast from base up to top of head frame shall be around 30mtrs. Polygonal high mast tower with fixed head frame along with provision for using man rider with each mast for accessing the head frame platform. Structural design of the high mast should be carried out as per the technical report no.7/ relevent standard and regulation. The mast should be designed considering base gust wind speed 33 km/Sec as per IS 875 and thickness of GI coating should withstand as per wind speed 33Km/sec. Price shall include suitable 1.2m Lightning Arrestor as per requirement. as per the directions of the Engineer-in-charge Make:-Bajaj, Crompton , Philips Analysis of Rates

4

1590253

6361012

... More
Design and construction of Foundation Design and construction of Casting of suitable Raft type foundation for the High Mast as per the directions of the Engineer-in-charge Analysis of Rates

4

325423

1301692

... More
External Man Rider Supply, Installation, Testing & Commissioning of external man rider unit as per the directions of the Engineer-in-charge Analysis of Rates

1

793077

793077

... More
Aviation Light Supply, Installation, Testing & Commissioning of Medium intensity LED type Aviation obstruction luminaire to be mounted on High Mast complete with accessories as per the directions of the Engineer-in-charge Analysis of Rates

8

8146

65168

... More
High Mast Lighting Panel Supplying, installation, testing and commissioning of cubicle type IP 55 outdoor High mast Lighting Feeder Pillar suitable for 415 volt, 3 phase, 4 wire 50 HZ AC supply system, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates, including cleaning and finishing complete with 7 tank process having extensible type TPN aluminum alloy bus bar of high conductivity, with base frame of M.S. section of suitable size, copper earth bar of size 25mmx 5mm at the rear with 2 nos earth stud, complete with control wire, cable alleys, cable gland plates, including following items mentioned below. The feeder pillar should be suitable for pedestrail mounting above 500mm from the ground floor with necessary base frame/ civil works for suitable foundation.as per the directions of the Engineer-in-charge Analysis of Rates

4

191830

767320

... More
Supply & laying of aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. [CCI (Mumbai/Nasik), Fort Gloster (Kolkata), Asian (Thane/Silvasa), Universal (Satna), Nicco (Kolkata/Baripara), ICL (Rajpura), Diamond, Havells make] & for small works upto value of cable for Rs. 25.0 Lacs Kalinga (Gold), Suraj, Delton, Grandly & Polycab make can be used) complete in all respect as per the directions of the Engineer-in-charge PWD-2018/PS No-501 3.5C X 95Sq.mm.

300

700

210000

... More
Supply & laying of aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. [CCI (Mumbai/Nasik), Fort Gloster (Kolkata), Asian (Thane/Silvasa), Universal (Satna), Nicco (Kolkata/Baripara), ICL (Rajpura), Diamond, Havells make] & for small works upto value of cable for Rs. 25.0 Lacs Kalinga (Gold), Suraj, Delton, Grandly & Polycab make can be used) complete in all respect as per the directions of the Engineer-in-charge PWD-2018/PS No-501 3.5C X 150Sq.mm.

200

957

191400

... More
Supply and laying of following sizes 1.1 KV FRLS XLPE insulated cable with copper conductor, PVC inner sheathed, unarmoured, overall PVC sheathed stranded and twisted cable in conformity to the technical specification and as per latest IS - codes. 7C X 2.5Sq.mm. as per the directions of the Engineer-in-charge. Analysis of Rates

150

339

50850

... More
Supply & fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, making connections etc. complete in all respects as per direction of the Engineer-in-charge. PWD-2018/PS No-504 95Sqmm.

20

88

1760

... More
Supply & fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, making connections etc. complete in all respects as per direction of the Engineer-in-charge. PWD-2018/PS No-504 150Sqmm.

20

146

2920

... More
S/F of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 Mtr. below ground level complete with 20 mm dia G.I. pipe & funnel for watering & one earthing lead of one no. 8 to SWG GI wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of GI pipe and GI wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of char-coal/coke & salt atleast 150 mm thick all-around etc. complete in all respect as per the directions of the Engineer-in-charge. PWD-2018/PS No-702

20

5350

107000

... More
Supply and laying of 25mmx3mm G.I. strip from earth electrode directly in the ground as required complete in all respect as per the directions of the Engineer-in-charge PWD-2018/PS No-710

600

170

102000

... More
Main Power control panel Floor mounted type with 400amp four pole main incomer complete with indication, metering, protection as per the directions of the Engineer-in-charge Analysis of Rates

1

840000

840000

... More
S/L of 120mm dia. DWC pipe for drawing of power cable across the road by drilling of 150mm dia. at 1mtr. Below the road level the work should be done by manual Trenchless method. Complete in all respect per direction of Engineer-in-charge YEIDA SOR-13

40

697

27880



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.