Yamuna Expressway Industrial Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Yamuna Expressway Industrial Development Authority - YEIDA Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Nov 2024
Closing Date27 Nov 2024
Tender Amount₹ 2,28,44,799 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
HT RMU UNIT SECTION

-

-

-

... More
11 kV, indoor non extensible Load Break /VCB Panel, 11kV SF6 insulated compact switchgear having metal enclosed robotically sealed / welded stainless steel tank comprising 2nos 630 Load Break Isolator and one no 200 amp VCB in SF6 enclosure with self powered numerical overcurrent, short circuit and earth fault relay for Transformer complete as per specification as required.

-

-

-

... More
TRANSFORMER SECTION

-

-

-

... More
250 KVA 11KV/433 volts, Delta/Star, vector group DYN11, oil cooled ONAN transformer with OFF Load Tap Changers suitable for incoming voltage variation of +5.0% to -10% in equal steps of 2.5% to give a constant secondary voltage. The transformer shall be provided with fittings, accessories, protection, first filing of oil etc. including Buchholz relay oil/winding temperature, alarm/trip protection, surge arrestor, complete as per specifications and as required. The Losses shall be as per IS 1180 Level -I as per latest Amendment complete as required.

-

-

-

... More
LT SECTION

-

-

-

... More
INCOMING

-

-

-

... More
1 no. - 400 Amps 660 volt 4 pole MCCB 50kA complete with:

-

-

-

... More
4 nos - Cast resin current transformers of 400/5 ratio Class 1.0 for metering

-

-

-

... More
1 no. Multifuction Meter

-

-

-

... More
1 no. - Red/Green/AMBER ON/OFF/TRIP indicating lamps

-

-

-

... More
A Sets of Phase Indicating Lamp

-

-

-

... More
1 no - Microprocessor based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 100%-1000% with time setting ,instantaneous short circuit 150%-1500% and earth fault releases.

-

-

-

... More
The compact substation shall be complete with all interconnections, labels wiring, etc as required

2

1993345

3986690

... More
SUB HEAD II- DG Set and Associates Work

-

-

-

... More
Installation, testing & commissioning of Diesel Engine Set Silent type with 415volts at 1500 RPM,0.8 lagging power factor at 415 volts suitable for 50Hz, 3 phase system and for 0.80 load factor and consisting of following rating for site conditions, complete with base frame, lube oil system, Radiator Cooled, required batteries, electronic governor, instrumentation, day service fuel tank of 990 liters for each DG set, residential type exhaust silencers, alarms, engine mounted control panel, Resistoflex make anti vibration pads, Alternator (Stamford/AVK SEGC) direct coupled to Engine along with static excitation system and AVR panel and all required accessories complete as required and as per specifications. Power cabling, earthing, DG Panel and any other associated electrical work shall be carried out by Electrical contractor and hence is not included in the scope of this work. However the required coordination with Electrical Contractor is in the scope of work.

-

-

-

... More
Diesel Engine

-

-

-

... More
Diesel Engine radiator cooled electronic start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 degree C, 50% RH at 1000metre MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operations. The engine will be fitted complite with all the required accessories.

-

-

-

... More
Digital Display for the following

-

-

-

... More
Start & Stop switch with Key

-

-

-

... More
Water temperature indication

-

-

-

... More
Lubrication oil pressure indication

-

-

-

... More
Lubrication oil temperature indication

-

-

-

... More
Battery charging indication

-

-

-

... More
RPM indication

-

-

-

... More
Over speed indication

-

-

-

... More
Low lube oil trip indication

-

-

-

... More
Ingine hours indication

-

-

-

... More
Alternator

-

-

-

... More
Synchronous alternator following rating suitable for 415 volts at 1500 RPM 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C 50% RH and at 1000 meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self excited and self regulated through AVR confirming to IS 4722/BS 2613 suitable for tropical conditions and with class H insulation.

-

-

-

... More
Base Frame and Foundation

-

-

-

... More
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangements as per recommandation of manufacturer.

-

-

-

... More
Exhaust System

-

-

-

... More
Dry exhaust mainfold with hospital exhaust silencer

-

-

-

... More
Fuel Tank

-

-

-

... More
Daily service fuel tank of 990 ltr capacity fabricated out of 2mm thick MS sheet complite with all standard accessories and fuel piping between fuel tank and diesel ingine with MS class C pipes of suitable dia, complite with valves, level indications and accessories as required as per specifications.

-

-

-

... More
Starting System

-

-

-

... More
12V/24V DC starting system comprising of starter motors voltage regulator and arrangements for initial excitation complite with suitable nos. of batteries (25 plates, 360/180 AH capacity lead acid type) as required as per specification

-

-

-

... More
Accoustic and weather proof enclosure with arrangements for fresh air intake for cooling of the engine and alternator, extraction, discharging hot air into the atmosphere as per specifications.

-

-

-

... More
The D.G. sets shall be inclusive of but not limited to the following standard accessories:

-

-

-

... More
Radiator cooled system .

-

-

-

... More
Fly Wheel to suit flexible/rigid coupling.

-

-

-

... More
Fly wheel housing complete with starter gear ring and coupling.

-

-

-

... More
Fuel hoses.

-

-

-

... More
Electronic Governor.

-

-

-

... More
Air Cleaner with Vacuum Indicator.

-

-

-

... More
Fuel and Lube Oil Filter.

-

-

-

... More
By pass filter

-

-

-

... More
Corrosion inhibitor coolant.

-

-

-

... More
Fuel Pump PT Type.

-

-

-

... More
Water Pump.

-

-

-

... More
Lube Oil Pump.

-

-

-

... More
Electric Starter 24 Volts DC.

-

-

-

... More
Battery Charging Alternator with Built-in-regulator - 24 Volts, 30 Amps.

-

-

-

... More
Residential Silencer including baffle plates and 75mm thick LRB rock wool (64 Kg/m3 density) insulation clad with 26 SWG aluminium sheet cladding.

-

-

-

... More
Expansion below

-

-

-

... More
Flue pipe of required size from DG set FLUE OUTLET upto Silencer.

-

-

-

... More
Safety Control against low Lube oil pressure, over speed and high cooling water temperature along with tripping.

-

-

-

... More
Lube Oil Cooler.

-

-

-

... More
Flexible Pipe joints for Silencer.

-

-

-

... More
Vibration Damper.

-

-

-

... More
Anti Vibration Pads.

-

-

-

... More
Rating of DG Sets as Follows :-

-

-

-

... More
160 kVA Silent Type

1

1650000

1650000

... More
DG Setrs shall be suitable for Auto ON/OFF incase of Failure and Interlocking with PLC in the Panel LT Panel

-

-

-

... More
D.G. panel described as above, complete as required and as per specifications.

-

-

-

... More
Supply, erection, testing and commissioning of exhaust piping Min. 5mm Thick of following sizes with welding joint including bends, MS pipe supports, clamps, dash fastener, nuts, bolts etc., with minimum 50mm thick rockwooll (150Kg/Cub Mtr.) covered with 26 SWG aluminium sheet claddings etc. complete as required and as per specifications. insluding Structure along with DG Sets

-

-

-

... More
125 mm dia. NB

20

3500

70000

... More
SS Bellows

2

8000

16000

... More
MS Support structure

3000

130

390000

... More
Control Cable :

-

-

-

... More
Supply, laying, testing and commissioning of the following sizes of 1.1 KV grade XLPE insulated and PVC sheathed copper conductor armoured stranded control cable conforming latest IS complete as required.

-

-

-

... More
4 Core x 2.5 Sq.mm Cable

100

348

34800

... More
8 Core x 2.5 Sq.mm Cable

100

607

60700

... More
Control Cables termination:

-

-

-

... More
Supplying of all materials and making terminations of control cable terminations for control cables as per item 3.0 above complete with single brass compression glands, copper lugs etc. as required:

-

-

-

... More
2 Core x 2.5 Sq.mm Cable

6

359

2154

... More
4 Core x 2.5 Sq.mm Cable

6

333

1998

... More
Supply, installation, testing and commissioning of 990 litres capacity day oil storage tank fabricated from 2 mm thick MS plates. Tank shall include 450 mm ID manhole cover, level indicator and flanged connection for inlet, outlet, overflow drain and probe provision for level controller. Tank shall be mounted on 2 m high structure support with access ladder (painted with 2 coats of red oxide primer). (Day oil Tank)

1

45000

45000

... More
Providing & fixing M.S. class ‘C’ (heavy duty) pipe & fittings like tees, elbows, junctions, unions, bends, plugs etc. Including a coat of Synthetic enamel paint over two coats of primer complete as required.

-

-

-

... More
25 mm dia

30

515

15450

... More
Providing & fixing CI ball valves of the following sizes suitable for pressure of 10 kg/sqcm complete with all necessary fittings

-

-

-

... More
25 mm dia

4

6500

26000

... More
Providing and fixing gun metal flot valve with necessary fittings complete as required.

-

-

-

... More
25 mm dia

2

2500

5000

... More
Providing "No smoking and Flammable" sign boars as per requirements of Petrolium Rules as required.

1

3500

3500

... More
Supply and installation of 4 nos. fire bucket with sand with suitable bracket complite as required.

1

9500

9500

... More
Supply and fixing of 9 kg foam type fire extinguisher complite as required.

2

5500

11000

... More
11 KV Switchgear Panels

-

-

-

... More
Design, Manufacture, Supply, delivery & Coordination with Contractor for Installation , Testing and commisssioning of following panel totally enclosed with CRCA sheet steel clad floor, mounting, epoxy based powder coating vermin proof, fully interlocked horizontal isolation, and extensible, horizontal draw out, vacuum insulated, metal clad switch board having single/double isolation features complete with circuits as detailed below. The switch board would be complete with necessary insulation – silicon based Raychem or equivalent insulated copper bursars, earthing switch/Truck, Wiring, labels, cable eyes, cable termination to receive XLPE cables, foundation bolts and suitable for operation on 11 KV 3 phase, 50 cycle, earthed system with a rupturing capacity of 350 MVA at 11 KV for 3 seconds.

-

-

-

... More
Incoming 11 KV Panel Board

-

-

-

... More
1 – Air insulated metal clad housing

-

-

-

... More
1 – Set of 3 phase, insulated copper bus bars 630 amps rating.

-

-

-

... More
6 – Single pole cluster type isolating contacts i.e. plug and switches.

-

-

-

... More
1 – Triple pole draw out trolly mounted 11 KV 350 MVA, 630 Amps Vacuum circuit breaker fitted with arc control devices.

-

-

-

... More
1 – Trip free 240 V AC, motor charged spring release closing mechanism complete with necessary auxiliary switches, emergency hand trip device and mechanical ‘OFF’ & ‘ON’ indicators.

-

-

-

... More
6 nos NO/NC contacts

-

-

-

... More
1 – 24 Volt DC shunt trip coil & closing coil.

-

-

-

... More
3 – Dual core dual ratio cast resin current transformers of ratio 250-125/5 Class 5P10 and Class 1.0, 15 VA burden for protection & metering.

-

-

-

... More
1-3 Phase cast resin horizontal draw out bus potential transformer ratio 11 KV / √3 : 110 / √3 Volt, class 1.0, 100 VA, connected star/star with H.V and L.V. connections, H.V. fuses and LV MCB of adequate rating to withstand fault level in P.T circuit, isolating plugs for H.V. and L.V. connection.

-

-

-

... More
1- common Hooter

-

-

-

... More
1 – Strip heater to prevent absorption of moisture.

-

-

-

... More
The instrument and relay panel fitted with followings

-

-

-

... More
1 – Digital voltmeter 0 – 12 KV with 3 way and OFF selection facility.

-

-

-

... More
1 – Digital Ammeter (0-250) amps with 3 way and OFF selection facility.

-

-

-

... More
1 no.Multi function Meter (MFM-1) with RS 485 of 1.0 accuracy to measure voltage, current, power factor, frequency, KW , KVA, KWH, KVAh.

-

-

-

... More
1 – no. circuit breaker control switch for electrical (T/N/C)

-

-

-

... More
1 – Triple pole numerical I.D.M.T. over current & earth fault relay with two outer elements connected for over current protection and the middle element for earth fault protection over current setting 50% - 200% Earth fault setting 20% - 80% (51 and 51N)

-

-

-

... More
1 – Master trip relay (86)

-

-

-

... More
1 – Trip circuit Supervision relay.(95)

-

-

-

... More
1 – Anti pumping relay (94)

-

-

-

... More
1 – Over Voltage relay (59)

-

-

-

... More
1 – Set of red / green indicating lamps for close and open position with MCB.

-

-

-

... More
1 – Amber indicting lamp for auto trip with MCB

-

-

-

... More
1 – Clear indicating lamp for trip circuit healthy with MCB

-

-

-

... More
1 – Set of RYB Phase indicating lamps one per phase with MCB

-

-

-

... More
1 - Blue indicating lamp for spring charged.with MCB

-

-

-

... More
1 – Push button on front door for emergency trip.

-

-

-

... More
1 – Cable end box suitable for cable termination to receive 11 KV 3 core 240 sq.mm XLPE cable.

-

-

-

... More
11KV, 1No Incoming Panel board as described above & as per specification including Power Pack for Auxiliary Services

1

557713

557713

... More
415 Volts Panel

-

-

-

... More
Design, manufacture, supplying, erection, testing and commissioning of the following front operated front access 2mm thick steel enclosure free standing, outdoor type, dust and vermin proof, Panel with IP42 Protection & Feeder Pillar with IP 55 whether proof protection with hinged and lockable doors complete with interconnections, electrolytic aluminium crimping lugs, brass glands, bonding to earth and painting,, suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system, and with 25 MVA rupturing capacity at 415 volts.

-

-

-

... More
Note : The following provisions shall be required to be made in the switchboard detailed below:

-

-

-

... More
The switchboard shall be have provision for entry of all cables / bus duct from the top / bottom as required.

-

-

-

... More
All live accessible parts shall be shrounded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrounds and bus bar supports shall be used.

-

-

-

... More
Suitable tinned copper extension links for incoming / outgoing cables shall be provided wherever required.

-

-

-

... More
Control circuits includes breaker control switch, auto manual selector switch, spring charging trip indication Timer, control wiring, Auxiliary contactors MCB' as required at site.

-

-

-

... More
All the incomers breakers shall be interlocked to avoid parallel operation.

-

-

-

... More
All ACB, fault level breaking capacity indicates Ics value at 415 volts. (Ics = Icu = Icw = 100%) for 1 sec.

-

-

-

... More
MCCB's in the MAIN LT Panel shall be with inbuilt Microprocessor based overload and short circuit & Earth fault release as per BOQ .

-

-

-

... More
Link and drops from ACB / MCCB shall be designed for full rated current of ACB / MCCB rating at same amount of current density as of main bus bar.

-

-

-

... More
Space heater / light / air filter/exhaust fan shall be provided for each vertical compartment.

-

-

-

... More
All CT's shall have same fault level rating as their respective circuit breaker.

-

-

-

... More
Bus bar size/rating, type of insulator, size of insulator, support for insulator, spacing of busbar support shall be as per CPRI approved design.

-

-

-

... More
MAIN PANEL ( IP 42 PROTECTION)

-

-

-

... More
INCOMER -I & II (200 KVA CSS 1W/1S)

-

-

-

... More
2 nos.- 400 amps 35 kA 415 volt 4P MCCB with 4P MCCB Contactor with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200%

-

-

-

... More
3 nos - Cast resin current transformers of 400/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-400 amps with 3 way and OFF selector switch

-

-

-

... More
1 - Voltmeter scaled 0-400 volts with 3 way and Off selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
1 set of three RYB phase indicating lamps

-

-

-

... More
1- Amber indicating lamp for auto trip

-

-

-

... More
1- Blue indicating lamp for spring charged

-

-

-

... More
Motor wound Spring closing meachanism

-

-

-

... More
1 no Reverse Power Relay (32)

-

-

-

... More
1 no.- 400 amps 35 kA 415 volt 4P MCCB with 4P MCCB Contactor with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200%

-

-

-

... More
3 nos - Cast resin current transformers of 400/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-400 amps with 3 way and OFF selector switch

-

-

-

... More
1 - Voltmeter scaled 0-400 volts with 3 way and Off selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
1 set of three RYB phase indicating lamps

-

-

-

... More
1- Amber indicating lamp for auto trip

-

-

-

... More
1- Blue indicating lamp for spring charged

-

-

-

... More
Motor wound Spring closing meachanism

-

-

-

... More
1 no Reverse Power Relay (32)

-

-

-

... More
BUS COUPLER

-

-

-

... More
1 nos - 400 Amps 415 volt 50 KA 4 pole MCCB with contactor with complete with:

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
BUS BAR SECTION -I&II

-

-

-

... More
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 500 amps having a minimum current density of 1.0 amp per sq mm and suitable to with stand symmetrical fault level of 35 kA at 415 volts. The neutral busbar is to be of 50% capacity.

-

-

-

... More
OUT GOING SECTION -I & II

-

-

-

... More
2 nos. 250 amps 35 kA 415 volt TPN MCCB with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200% complete with :

-

-

-

... More
3 nos - Cast resin current transformers of 250/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-250 amps with 3 way and OFF selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
2 nos. 160 amps 35 kA 415 volt TPN MCCB with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200% complete with :

-

-

-

... More
3 nos - Cast resin current transformers of 160/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-160 amps with 3 way and OFF selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
2 nos. 63 amps 35 kA 415 volt TPN MCCB with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200% complete with :

-

-

-

... More
3 nos - Cast resin current transformers of 60/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-60 amps with 3 way and OFF selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
1 no. 32 amps 35 kA 415 volt TPN MCCB with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200% complete with :

-

-

-

... More
3 nos - Cast resin current transformers of 32/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-32 amps with 3 way and OFF selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
The Main Panel shall be complete with all interconnections, labels wiring, etc as required

1

775072

775072

... More
CAPACITOR PANEL I&II (52.2 KVAR) ( IP 42 PROTECTION)

-

-

-

... More
INCOMER

-

-

-

... More
1 no.- 160 amps 35 kA 415 volt 4P MCCB with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200%

-

-

-

... More
3 nos - Cast resin current transformers of 160/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-160 amps with 3 way and OFF selector switch

-

-

-

... More
1 - Voltmeter scaled 0-250 volts with 3 way and Off selector switch

-

-

-

... More
5 step automatic power factor correction relay to sense and monitor the system power factor and provide impulses for operation of 6 capacitor circuits as below.

-

-

-

... More
1 set of three RYB phase indicating lamps

-

-

-

... More
BUS BAR

-

-

-

... More
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm and suitable to with stand symmetrical fault level of 35 kA at 415 volts. The neutral busbar is to be of 50% capacity.

-

-

-

... More
OUT GOINGS

-

-

-

... More
1 nos. 63 amp TPN 35 kA MCCB with thermal over load and magnetic short circuit release and each complete with followings

-

-

-

... More
3 pole capacitor grade contactor suitable for automatic switching of 25 kVAR capacitor bank

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
Auto/Manual Selector Switch

-

-

-

... More
ON/OFF Push Button

-

-

-

... More
25 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required .

-

-

-

... More
1 nos. 32 amp TPN 35 kA MCCB with thermal over load and magnetic short circuit release and each complete with followings

-

-

-

... More
3 pole capacitor grade contactor suitable for automatic switching of 12.5 kVAR capacitor bank

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
Auto/Manual Selector Switch

-

-

-

... More
ON/OFF Push Button

-

-

-

... More
12.5 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required .

-

-

-

... More
2 nos. 32 amp TPN 35 kA MCCB with thermal over load and magnetic short circuit release and each complete with followings

-

-

-

... More
3 pole capacitor grade contactor suitable for automatic switching of 7.5 kVAR capacitor bank

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
Auto/Manual Selector Switch

-

-

-

... More
ON/OFF Push Button

-

-

-

... More
7.5 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required .

-

-

-

... More
The Capacitor Panel shall be complete with all interconnections, labels wiring, etc as required

2

142577

285154

... More
CSF2 BUILDING PANEL ( IP 42 PROTECTION -INDOOR DUTY)

-

-

-

... More
INCOMER

-

-

-

... More
2 no.- 250 amps 25 kA 415 volt 4P MCCB with Thermal over load and Magnetic short circuit relase complete with

-

-

-

... More
3 nos - Cast resin current transformers of 250/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-250 amps with 3 way and OFF selector switch

-

-

-

... More
1 - Voltmeter scaled 0-500 volts with 3 way and Off selector switch

-

-

-

... More
BUS COUPLER

-

-

-

... More
1 nos - 250 Amps 415 volt 35 KA 4 pole MCCB with complete with:

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
BUS BAR

-

-

-

... More
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm and suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity.

-

-

-

... More
OUT GOINGS

-

-

-

... More
9 nos. 63 amp 4P 10 kA MCB with thermal over load and magnetic short circuit release

-

-

-

... More
6 nos. 40 amp 4P 10 kA MCB with thermal over load and magnetic short circuit release

-

-

-

... More
Electrically Mechanically Interlocked Incomer, Buscoupler & Busbar

-

-

-

... More
The Panel shall be complete with all interconnections, labels wiring, etc as required

1

191912

191912

... More
FEEDER PILLAR (OUTDOOR TYPE)

-

-

-

... More
Fabrication, supply, installation, testing & commissioning of outdoor type compartmentalized feeder pillar tapered (hut type) made out of 2mm thick CRCA sheet having separate cable and bus bar alley double door arrangement with two leaf door on front side and single door with double leaf on rear side with locking arrangement, having 100 amp TPN Aluminum bus bar of full length with base frame made out of 50x50x6mm thick angle iron having 150 mm legs duly erection in ground with construction of cement concrete complete with connection and interconnection with copper conductor PVC insulated cables / insulated copper conductor strip of appropriate size and terminals blocks (on outgoing) including supplying and fixing following switch gears & accessories there in powder coating, labeling, earthing etc. complete as required

-

-

-

... More
INCOMER

-

-

-

... More
1 no. 63 Amps 10 kA 4 MCB with thermal over load and magnetic short circuit releaes

-

-

-

... More
BUS BAR

-

-

-

... More
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 100 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 10 KA at 415 volts. The neutral busbar is to be of 100% capacity.

-

-

-

... More
INDICATING PANEL

-

-

-

... More
The incomers shall have the following indicating panel

-

-

-

... More
3 nos Cast resin current transformers of 63/5 ratio Class 1.0 for metering

-

-

-

... More
1 no ammeter of 96 mm sq scaled 0-63 amps with 3 way and OFF selector switch

-

-

-

... More
1 no voltmeter of 96 mm sq scaled 0- 500 volts with 3 way & OFF selector switch

-

-

-

... More
1 set of indicating lamps (ON. OFF)

-

-

-

... More
1 set of phase indicating lamps

-

-

-

... More
OUT GOINGS

-

-

-

... More
1 nos. 32 Amps 230 volt 10 kA 4P MCB with thermal magnetic protective releases.

-

-

-

... More
3 nos. 32 Amps 230 volt 10 kA DP MCB with thermal magnetic protective releases.

-

-

-

... More
1 nos 40 amp 10 kA 4P MCB with thermal magnetic protective releases with 40 amp TP Contactor with Dual setting 24 hour calibrated time switch for automatic operation of the supply, and 12 nos 6/10/16 amp SP 10 kA MCB's as outgoing.

-

-

-

... More
The Feeder Pillar shall be complete with all interconnections, busbars etc. complete as per design to be approved by the Architects.

1

77401

77401

... More
Cable & Termination

-

-

-

... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. UPPWD-501

-

-

-

... More
3.5 core 240 sq mm

70

1379

96530

... More
3.5 core 185 sq mm

70

1140

79800

... More
3.5 core 150 sq mm

120

957

114840

... More
3.5 core 120 sq mm

100

824

82400

... More
3.5 core 50 sq mm

50

492

24600

... More
4 core 16 sq mm

250

343

85750

... More
4 core 10 sq mm

120

327

39240

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Based on DSR-9.1

-

-

-

... More
3.5 core 240 sq mm. Based on DSR-9.1.29

32

795

25462.4

... More
3.5 core 120 sq mm. Based on DSR-9.1.25

32

499

15996.8

... More
3.5 core 70 sq mm . Based on DSR-9.1.23

32

441

14112

... More
3.5 core 50 sq mm. Based on DSR-9.1.22

36

392

14133.6

... More
3.5 core 35 sq mm. Based on DSR-9.1.21

24

353

8484

... More
4 core 25 sq mm. Based on DSR-9.1.34

16

335

5366.4

... More
4 core 16 sq mm . Based on DSR-9.1.33

48

331

15907.2

... More
4 core 10 sq mm. Based on DSR-9.1.32

38

297

11316.4

... More
4 core 6 sq mm. Based on DSR-9.1.31

12

297

3573.6

... More
S/L of 90mm dia. DWC pipe for drawing of power cable across the road by drilling of 120mm dia. at 1mtr. Work should be done by manual Trenchless method. Complete in all respect per direction of Engineer-in-charge YEIDA SOR-12

50

637

31850

... More
S/L of 120mm dia. DWC pipe for drawing of power cable across the road by drilling of 150mm dia. at 1mtr. Below the road level the work should be done by manual Trenchless method. Complete in all respect per direction of Engineer-in-charge YEIDA SOR-13

50

697

34850

... More
S/L of 160mm dia. DWC pipe for drawing of power cable across the road by drilling of 190mm dia. at 1mtr. Below the road level the work should be done by manual Trenchless method. Complete in all respect per direction of Engineer-in-charge YEIDA SOR-14

100

740

74000

... More
S/L of 200mm dia. DWC pipe for drawing of power cable across the road by driling of 230mm dia. at 1mtr. Below the road level the work should be done by manual Trenchless method. Complete in all respect per direction of Engineer-in-charge YEIDA SOR-15

100

796

79600

... More
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. Based on DSR-14.1.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness. Based on DSR-4.1.1

400

650

260000

... More
150 mm width X 50 mm depth X 1.6 mm thickness. Based on DSR-4.1.2

100

758

75840

... More
200 mm width X 50 mm depth X 1.6 mm thickness. Based on DSR-4.1.3

50

933

46665

... More
300 mm width X 50 mm depth X 1.6 mm thickness. Based on DSR-4.1.4

20

1102

22054

... More
450 mm width X 50 mm depth X 2.0 mm thickness. Based on DSR-4.1.5

30

1725

51750

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duly)in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement: 2 fine sand) including trenching (75 cm deep) and refilling etc as required. Based on DSR-14.14.

-

-

-

... More
100 MM DIA. Based on DSR-14.14.1

100

443

44350

... More
150 MM DIA. Based on DSR-14.14.2

100

456

45630

... More
250 MM DIA. Based on DSR-14.14.3

400

634

253600

... More
300 MM DIA. Based on DSR-14.14.4

10

705

7057

... More
Earthing

-

-

-

... More
Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. UPPWD-701

2

4076

8152

... More
Supply and burying of G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. UPPWD-703

10

5380

53800

... More
Supply and burying of copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. UPPWD-705

8

10450

83600

... More
Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect. UPPWD-718

200

1110

222000

... More
Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. UPPWD-717

250

150

37500

... More
Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect. UPPWD-716

100

90

9000

... More
Supply and fixing of one number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. UPPWD-721

400

200

80000

... More
Lightning Conductor

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate i ncluding holes etc. complete as required. Based on DSR-6.2

5

235

1175

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run). Based on DSR-6.7

120

522

62724

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) . Based on DSR-6.8

40

522

20908

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. Based on DSR-6.12

5

556

2783

... More
Earthing with G.I earth Plate 600 x 600 x 6 mm thick including accessories and providing mansory enlsoure with cover plate having locking arrangment and watering pipe of 2.7 metre long, with charcoal /coke and salt as required. Based on DSR-5.2

5

4141

20707

... More
Jointing copper /G.I. tape (with another copper/ GI tape, base of the finial or any other metallie object) by riveting /nut bolting/sweating and soldering etc as required. Based on DSR-6.4

2

47

94.2

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. Based on DSR-6.14

60

378

22698

... More
External Lighting & Poles

-

-

-

... More
Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. UPPWD-641

13

16500

214500

... More
Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. UPPWD-642

3

17100

51300

... More
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. UPPWD-1421 CAT- AAA

19

4940

93860

... More
Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. UPPWD-1442 CAT- AAA

18

4070

73260

... More
Supply & Fixing of XLPE insulated, Copper un-armoured Control cable 1100V grade etc. (A) 3 x 4 sq. mm. Based on DSR - 9.1.7

400

277

110840

... More
Supply & Fixing of XLPE insulated Aluminium un-armoured Cable. (A) 3 x 6 sq. mm. UPPWD-501

200

284

56800

... More
UPS SYSTEM

-

-

-

... More
Supply ,installation, testing and commissioning of IGBT Rectifier & Inverter based UPS system comprising of 1 no 15 kVA units with battery bank backup of 30 minutes duration for full load with all standards fittings, accessories, protection, instruments, indications and controls including but not restricted to transformer, rectifire, inverter, SMF battery with float cum boost battery charger, static bypass switch, maintenance bypass, output isolation transformer, interconnections etc.including warranty and free all inclusive comprehensive maintenance services for two years for UPS and battery bank after the date of handing over complete as per specification and as required.

1

545201

545201

... More
For CSF-04 (Electronic Assembly Facility)

-

-

-

... More
250kVA Compact Sub-Station

-

-

-

... More
Supply, Installation, testing, commissioning and transportation at site of Outdoor Package type substation comprising of distribution transformer, RMU, LT switchgear with internal lighting, earthing, padlocking etc. without oil pits. The enclosure shall have modular construction using GI sheets and shall be painted with polyurethane paint from exterior. Connection between RMU and Transformer shall be by Aluminium XLPE HT Cable including the cable termination/alluminium bus bar and from transformer to LT ACB shall be by alluminium bus bar. Two nos. copper & two nos GI links to be provided for neutral & body earthing.The substation shall have following equipments.

-

-

-

... More
HT RMU UNIT SECTION

-

-

-

... More
11 kV, indoor non extensible Load Break /VCB Panel, 11kV SF6 insulated compact switchgear having metal enclosed robotically sealed / welded stainless steel tank comprising 2nos 630 Load Break Isolator and one no 200 amp VCB in SF6 enclosure with self powered numerical overcurrent, short circuit and earth fault relay for Transformer complete as per specification as required.

-

-

-

... More
TRANSFORMER SECTION

-

-

-

... More
250 KVA 11KV/433 volts, Delta/Star, vector group DYN11, oil cooled ONAN transformer with OFF Load Tap Changers suitable for incoming voltage variation of +5.0% to -10% in equal steps of 2.5% to give a constant secondary voltage. The transformer shall be provided with fittings, accessories, protection, first filing of oil etc. including Buchholz relay oil/winding temperature, alarm/trip protection, surge arrestor, complete as per specifications and as required. The Losses shall be as per IS 1180 Level -I as per latest Amendment complete as required.

-

-

-

... More
LT SECTION

-

-

-

... More
INCOMING

-

-

-

... More
1 no. - 400 Amps 660 volt 4 pole MCCB 50kA complete with:

-

-

-

... More
4 nos - Cast resin current transformers of 400/5 ratio Class 1.0 for metering

-

-

-

... More
1 no. Multifuction Meter

-

-

-

... More
1 no. - Red/Green/AMBER ON/OFF/TRIP indicating lamps

-

-

-

... More
A Sets of Phase Indicating Lamp

-

-

-

... More
1 no - Microprocessor based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 100%-1000% with time setting ,instantaneous short circuit 150%-1500% and earth fault releases.

-

-

-

... More
The compact substation shall be complete with all interconnections, labels wiring, etc as required

2

1993345

3986690

... More
DG Set and Associates Work

-

-

-

... More
Installation, testing & commissioning of Diesel Engine Set Silent type with 415volts at 1500 RPM,0.8 lagging power factor at 415 volts suitable for 50Hz, 3 phase system and for 0.80 load factor and consisting of following rating for site conditions, complete with base frame, lube oil system, Radiator Cooled, required batteries, electronic governor, instrumentation, day service fuel tank of 990 liters for each DG set, residential type exhaust silencers, alarms, engine mounted control panel, Resistoflex make anti vibration pads, Alternator (Stamford/AVK SEGC) direct coupled to Engine along with static excitation system and AVR panel and all required accessories complete as required and as per specifications. Power cabling, earthing, DG Panel and any other associated electrical work shall be carried out by Electrical contractor and hence is not included in the scope of this work. However the required coordination with Electrical Contractor is in the scope of work.

-

-

-

... More
Diesel Engine

-

-

-

... More
Diesel Engine radiator cooled electronic start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 degree C, 50% RH at 1000metre MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operations. The engine will be fitted complite with all the required accessories.

-

-

-

... More
Digital Display for the following

-

-

-

... More
Start & Stop switch with Key

-

-

-

... More
Water temperature indication

-

-

-

... More
Lubrication oil pressure indication

-

-

-

... More
Lubrication oil temperature indication

-

-

-

... More
Battery charging indication

-

-

-

... More
RPM indication

-

-

-

... More
Over speed indication

-

-

-

... More
Low lube oil trip indication

-

-

-

... More
Ingine hours indication

-

-

-

... More
Alternator

-

-

-

... More
Synchronous alternator following rating suitable for 415 volts at 1500 RPM 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C 50% RH and at 1000 meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self excited and self regulated through AVR confirming to IS 4722/BS 2613 suitable for tropical conditions and with class H insulation.

-

-

-

... More
Base Frame and Foundation

-

-

-

... More
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangements as per recommandation of manufacturer.

-

-

-

... More
Exhaust System

-

-

-

... More
Dry exhaust mainfold with hospital exhaust silencer

-

-

-

... More
Fuel Tank

-

-

-

... More
Daily service fuel tank of 990 ltr capacity fabricated out of 2mm thick MS sheet complite with all standard accessories and fuel piping between fuel tank and diesel ingine with MS class C pipes of suitable dia, complite with valves, level indications and accessories as required as per specifications.

-

-

-

... More
Starting System

-

-

-

... More
12V/24V DC starting system comprising of starter motors voltage regulator and arrangements for initial excitation complite with suitable nos. of batteries (25 plates, 360/180 AH capacity lead acid type) as required as per specification

-

-

-

... More
Accoustic and weather proof enclosure with arrangements for fresh air intake for cooling of the engine and alternator, extraction, discharging hot air into the atmosphere as per specifications.

-

-

-

... More
The D.G. sets shall be inclusive of but not limited to the following standard accessories:

-

-

-

... More
Radiator cooled system .

-

-

-

... More
Fly Wheel to suit flexible/rigid coupling.

-

-

-

... More
Fly wheel housing complete with starter gear ring and coupling.

-

-

-

... More
Fuel hoses.

-

-

-

... More
Electronic Governor.

-

-

-

... More
Air Cleaner with Vacuum Indicator.

-

-

-

... More
Fuel and Lube Oil Filter.

-

-

-

... More
By pass filter

-

-

-

... More
Corrosion inhibitor coolant.

-

-

-

... More
Fuel Pump PT Type.

-

-

-

... More
Water Pump.

-

-

-

... More
Lube Oil Pump.

-

-

-

... More
Electric Starter 24 Volts DC.

-

-

-

... More
Battery Charging Alternator with Built-in-regulator - 24 Volts, 30 Amps.

-

-

-

... More
Residential Silencer including baffle plates and 75mm thick LRB rock wool (64 Kg/m3 density) insulation clad with 26 SWG aluminium sheet cladding.

-

-

-

... More
Expansion below

-

-

-

... More
Flue pipe of required size from DG set FLUE OUTLET upto Silencer.

-

-

-

... More
Safety Control against low Lube oil pressure, over speed and high cooling water temperature along with tripping.

-

-

-

... More
Lube Oil Cooler.

-

-

-

... More
Flexible Pipe joints for Silencer.

-

-

-

... More
Vibration Damper.

-

-

-

... More
Anti Vibration Pads.

-

-

-

... More
Rating of DG Sets as Follows :-

-

-

-

... More
160 kVA Silent Type

1

1650000

1650000

... More
DG Setrs shall be suitable for Auto ON/OFF incase of Failure and Interlocking with PLC in the Panel LT Panel

-

-

-

... More
D.G. panel described as above, complete as required and as per specifications.

-

-

-

... More
Supply, erection, testing and commissioning of exhaust piping Min. 5mm Thick of following sizes with welding joint including bends, MS pipe supports, clamps, dash fastener, nuts, bolts etc., with minimum 50mm thick rockwooll (150Kg/Cub Mtr.) covered with 26 SWG aluminium sheet claddings etc. complete as required and as per specifications. insluding Structure along with DG Sets

-

-

-

... More
125 mm dia. NB

20

3500

70000

... More
SS Bellows

2

8000

16000

... More
MS Support structure

3000

130

390000

... More
Control Cable :

-

-

-

... More
Supply, laying, testing and commissioning of the following sizes of 1.1 KV grade XLPE insulated and PVC sheathed copper conductor armoured stranded control cable conforming latest IS complete as required.

-

-

-

... More
4 Core x 2.5 Sq.mm Cable

100

348

34800

... More
8 Core x 2.5 Sq.mm Cable

100

607

60700

... More
Control Cables termination:

-

-

-

... More
Supplying of all materials and making terminations of control cable terminations for control cables as per item 3.0 above complete with single brass compression glands, copper lugs etc. as required:

-

-

-

... More
2 Core x 2.5 Sq.mm Cable

6

359

2154

... More
4 Core x 2.5 Sq.mm Cable

6

333

1998

... More
Supply, installation, testing and commissioning of 990 litres capacity day oil storage tank fabricated from 2 mm thick MS plates. Tank shall include 450 mm ID manhole cover, level indicator and flanged connection for inlet, outlet, overflow drain and probe provision for level controller. Tank shall be mounted on 2 m high structure support with access ladder (painted with 2 coats of red oxide primer). (Day oil Tank)

1

45000

45000

... More
Providing & fixing M.S. class ‘C’ (heavy duty) pipe & fittings like tees, elbows, junctions, unions, bends, plugs etc.. Including a coat of Synthetic enamel paint over two coats of primer complete as required.

-

-

-

... More
25 mm dia

30

515

15450

... More
Providing & fixing CI ball valves of the following sizes suitable for pressure of 10 kg/sqcm complete with all necessary fittings

-

-

-

... More
25 mm dia

4

6500

26000

... More
Providing and fixing gun metal flot valve with necessary fittings complete as required.

-

-

-

... More
25 mm dia

2

2500

5000

... More
Providing "No smoking and Flammable" sign boars as per requirements of Petrolium Rules as required.

1

3500

3500

... More
Supply and installation of 4 nos. fire bucket with sand with suitable bracket complite as required.

1

9500

9500

... More
Supply and fixing of 9 kg foam type fire extinguisher complite as required.

2

5500

11000

... More
11 KV Switchgear Panels

-

-

-

... More
Design, Manufacture, Supply, delivery & Coordination with Contractor for Installation , Testing and commisssioning of following panel totally enclosed with CRCA sheet steel clad floor, mounting, epoxy based powder coating vermin proof, fully interlocked horizontal isolation, and extensible, horizontal draw out, vacuum insulated, metal clad switch board having single/double isolation features complete with circuits as detailed below. The switch board would be complete with necessary insulation – silicon based Raychem or equivalent insulated copper bursars, earthing switch/Truck, Wiring, labels, cable eyes, cable termination to receive XLPE cables, foundation bolts and suitable for operation on 11 KV 3 phase, 50 cycle, earthed system with a rupturing capacity of 350 MVA at 11 KV for 3 seconds.

-

-

-

... More
Incoming 11 KV Panel Board

-

-

-

... More
1 – Air insulated metal clad housing

-

-

-

... More
1 – Set of 3 phase, insulated copper bus bars 630 amps rating.

-

-

-

... More
6 – Single pole cluster type isolating contacts i.e. plug and switches.

-

-

-

... More
1 – Triple pole draw out trolly mounted 11 KV 350 MVA, 630 Amps Vacuum circuit breaker fitted with arc control devices.

-

-

-

... More
1 – Trip free 240 V AC, motor charged spring release closing mechanism complete with necessary auxiliary switches, emergency hand trip device and mechanical ‘OFF’ & ‘ON’ indicators.

-

-

-

... More
6 nos NO/NC contacts

-

-

-

... More
1 – 24 Volt DC shunt trip coil & closing coil.

-

-

-

... More
3 – Dual core dual ratio cast resin current transformers of ratio 250-125/5 Class 5P10 and Class 1.0, 15 VA burden for protection & metering.

-

-

-

... More
1-3 Phase cast resin horizontal draw out bus potential transformer ratio 11 KV / √3 : 110 / √3 Volt, class 1.0, 100 VA, connected star/star with H.V and L.V. connections, H.V. fuses and LV MCB of adequate rating to withstand fault level in P.T circuit, isolating plugs for H.V. and L.V. connection.

-

-

-

... More
1- common Hooter

-

-

-

... More
1 – Strip heater to prevent absorption of moisture.

-

-

-

... More
The instrument and relay panel fitted with followings

-

-

-

... More
1 – Digital voltmeter 0 – 12 KV with 3 way and OFF selection facility.

-

-

-

... More
1 – Digital Ammeter (0-250) amps with 3 way and OFF selection facility.

-

-

-

... More
1 no.Multi function Meter (MFM-1) with RS 485 of 1.0 accuracy to measure voltage, current, power factor, frequency, KW , KVA, KWH, KVAh.

-

-

-

... More
1 – no. circuit breaker control switch for electrical (T/N/C)

-

-

-

... More
1 – Triple pole numerical I.D.M.T. over current & earth fault relay with two outer elements connected for over current protection and the middle element for earth fault protection over current setting 50% - 200% Earth fault setting 20% - 80% (51 and 51N)

-

-

-

... More
1 – Master trip relay (86)

-

-

-

... More
1 – Trip circuit Supervision relay.(95)

-

-

-

... More
1 – Anti pumping relay (94)

-

-

-

... More
1 – Over Voltage relay (59)

-

-

-

... More
1 – Set of red / green indicating lamps for close and open position with MCB.

-

-

-

... More
1 – Amber indicting lamp for auto trip with MCB

-

-

-

... More
1 – Clear indicating lamp for trip circuit healthy with MCB

-

-

-

... More
1 – Set of RYB Phase indicating lamps one per phase with MCB

-

-

-

... More
1 - Blue indicating lamp for spring charged.with MCB

-

-

-

... More
1 – Push button on front door for emergency trip.

-

-

-

... More
1 – Cable end box suitable for cable termination to receive 11 KV 3 core 240 sq.mm XLPE cable.

-

-

-

... More
11KV, 1No Incoming Panel board as described above & as per specification including Power Pack for Auxiliary Services

1

557713

557713

... More
415 Volts Panel

-

-

-

... More
Design, manufacture, supplying, erection, testing and commissioning of the following front operated front access 2mm thick steel enclosure free standing, outdoor type, dust and vermin proof, Panel with IP42 Protection & Feeder Pillar with IP 55 whether proof protection with hinged and lockable doors complete with interconnections, electrolytic aluminium crimping lugs, brass glands, bonding to earth and painting,, suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system, and with 25 MVA rupturing capacity at 415 volts.

-

-

-

... More
Note : The following provisions shall be required to be made in the switchboard detailed below:

-

-

-

... More
The switchboard shall be have provision for entry of all cables / bus duct from the top / bottom as required.

-

-

-

... More
All live accessible parts shall be shrounded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrounds and bus bar supports shall be used.

-

-

-

... More
Suitable tinned copper extension links for incoming / outgoing cables shall be provided wherever required.

-

-

-

... More
Control circuits includes breaker control switch, auto manual selector switch, spring charging trip indication Timer, control wiring, Auxiliary contactors MCB' as required at site.

-

-

-

... More
All the incomers breakers shall be interlocked to avoid parallel operation.

-

-

-

... More
All ACB, fault level breaking capacity indicates Ics value at 415 volts. (Ics = Icu = Icw = 100%) for 1 sec.

-

-

-

... More
MCCB's in the MAIN LT Panel shall be with inbuilt Microprocessor based overload and short circuit & Earth fault release as per BOQ .

-

-

-

... More
Link and drops from ACB / MCCB shall be designed for full rated current of ACB / MCCB rating at same amount of current density as of main bus bar.

-

-

-

... More
Space heater / light / air filter/exhaust fan shall be provided for each vertical compartment.

-

-

-

... More
All CT's shall have same fault level rating as their respective circuit breaker.

-

-

-

... More
Bus bar size/rating, type of insulator, size of insulator, support for insulator, spacing of busbar support shall be as per CPRI approved design.

-

-

-

... More
MAIN PANEL ( IP 42 PROTECTION)

-

-

-

... More
INCOMER -I & II (250 KVA CSS 1W/1S)

-

-

-

... More
2 nos.- 400 amps 35 kA 415 volt 4P MCCB with 4P MCCB Contactor with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200%

-

-

-

... More
3 nos - Cast resin current transformers of 400/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-400 amps with 3 way and OFF selector switch

-

-

-

... More
1 - Voltmeter scaled 0-400 volts with 3 way and Off selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
1 set of three RYB phase indicating lamps

-

-

-

... More
1- Amber indicating lamp for auto trip

-

-

-

... More
1- Blue indicating lamp for spring charged

-

-

-

... More
Motor wound Spring closing meachanism

-

-

-

... More
1 no Reverse Power Relay (32)

-

-

-

... More
1 no Reverse Power Relay (32)

-

-

-

... More
INCOMER -I (250 KVA DG SET 1W )

-

-

-

... More
1 no.- 400 amps 35 kA 415 volt 4P MCCB with 4P MCCB Contactor with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200%

-

-

-

... More
3 nos - Cast resin current transformers of 400/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-400 amps with 3 way and OFF selector switch

-

-

-

... More
1 - Voltmeter scaled 0-400 volts with 3 way and Off selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
1 set of three RYB phase indicating lamps

-

-

-

... More
1- Amber indicating lamp for auto trip

-

-

-

... More
1- Blue indicating lamp for spring charged

-

-

-

... More
Motor wound Spring closing meachanism

-

-

-

... More
1 no Reverse Power Relay (32)

-

-

-

... More
BUS COUPLER

-

-

-

... More
1 nos - 400 Amps 415 volt 50 KA 4 pole MCCB with contactor with complete with:

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
BUS BAR SECTION -I&II

-

-

-

... More
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 500 amps having a minimum current density of 1.0 amp per sq mm and suitable to with stand symmetrical fault level of 35 kA at 415 volts. The neutral busbar is to be of 50% capacity.

-

-

-

... More
OUT GOING SECTION -I & II

-

-

-

... More
2 nos. 250 amps 35 kA 415 volt TPN MCCB with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200% complete with :

-

-

-

... More
3 nos - Cast resin current transformers of 250/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-250 amps with 3 way and OFF selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
2 nos. 160 amps 35 kA 415 volt TPN MCCB with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200% complete with :

-

-

-

... More
3 nos - Cast resin current transformers of 250/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-250 amps with 3 way and OFF selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
2 nos. 63 amps 35 kA 415 volt TPN MCCB with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200% complete with :

-

-

-

... More
3 nos - Cast resin current transformers of 60/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-60 amps with 3 way and OFF selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
1 nos. 32 amps 35 kA 415 volt TPN MCCB with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200% complete with :

-

-

-

... More
3 nos - Cast resin current transformers of 60/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-60 amps with 3 way and OFF selector switch

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
The Main Panel shall be complete with all interconnections, labels wiring, etc as required

1

775072

775072

... More
CAPACITOR PANEL I&II ( 60 KVAR) ( IP 42 PROTECTION)

-

-

-

... More
INCOMER

-

-

-

... More
1 no.- 160 amps 35 kA 415 volt 4P MCCB with Thermal Magnetic based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200%

-

-

-

... More
3 nos - Cast resin current transformers of 160/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-160 amps with 3 way and OFF selector switch

-

-

-

... More
1 - Voltmeter scaled 0-160 volts with 3 way and Off selector switch

-

-

-

... More
5 step automatic power factor correction relay to sense and monitor the system power factor and provide impulses for operation of 6 capacitor circuits as below.

-

-

-

... More
1 set of three RYB phase indicating lamps

-

-

-

... More
BUS BAR

-

-

-

... More
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 500 amps having a minimum current density of 1.0 amp per sq mm and suitable to with stand symmetrical fault level of 35 kA at 415 volts. The neutral busbar is to be of 50% capacity.

-

-

-

... More
OUT GOINGS

-

-

-

... More
3 nos. 32 amp TPN 35 kA MCCB with thermal over load and magnetic short circuit release and each complete with followings

-

-

-

... More
3 pole capacitor grade contactor suitable for automatic switching of 12.5 kVAR capacitor bank

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
Auto/Manual Selector Switch

-

-

-

... More
ON/OFF Push Button

-

-

-

... More
12.5 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required .

-

-

-

... More
3 nos. 32 amp TPN 35 kA MCCB with thermal over load and magnetic short circuit release and each complete with followings

-

-

-

... More
3 pole capacitor grade contactor suitable for automatic switching of 7.5 kVAR capacitor bank

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
Auto/Manual Selector Switch

-

-

-

... More
ON/OFF Push Button

-

-

-

... More
7.5 kVAr hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc complete as required .

-

-

-

... More
The Capacitor Panel shall be complete with all interconnections, labels wiring, etc as required

2

202749

405498

... More
CSF4 BUILDING PANEL ( IP 42 PROTECTION -INDOOR DUTY)

-

-

-

... More
INCOMER

-

-

-

... More
2 no.- 250 amps 25 kA 415 volt 4P MCCB with Thermal over load and Magnetic short circuit relase complete with

-

-

-

... More
3 nos - Cast resin current transformers of 250/5 ratio Class 1.0 for metering

-

-

-

... More
1 - Digital Ammeter scaled 0-250 amps with 3 way and OFF selector switch

-

-

-

... More
1 - Voltmeter scaled 0-500 volts with 3 way and Off selector switch

-

-

-

... More
BUS COUPLER

-

-

-

... More
1 nos - 250 Amps 415 volt 35 KA 4 pole MCCB with complete with:

-

-

-

... More
Red/Green ON/OFF indicating lamps

-

-

-

... More
BUS BAR

-

-

-

... More
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm and suitable to with stand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity.

-

-

-

... More
OUT GOINGS

-

-

-

... More
8 nos. 63 amp 4P 10 kA MCB with thermal over load and magnetic short circuit release

-

-

-

... More
7 nos. 40 amp 4P 10 kA MCB with thermal over load and magnetic short circuit release

-

-

-

... More
2 nos. 40 amp DP 10 kA MCB with thermal over load and magnetic short circuit release

-

-

-

... More
2 nos. 32 amp 4P 10 kA MCB with thermal over load and magnetic short circuit release

-

-

-

... More
Electrically Mechanically Interlocked Incomer, Buscoupler & Busbar

-

-

-

... More
The Panel shall be complete with all interconnections, labels wiring, etc as required

1

206757

206757

... More
FEEDER PILLAR (OUTDOOR TYPE)

-

-

-

... More
Fabrication, supply, installation, testing & commissioning of outdoor type compartmentalized feeder pillar tapered (hut type) made out of 2mm thick CRCA sheet having separate cable and bus bar alley double door arrangement with two leaf door on front side and single door with double leaf on rear side with locking arrangement, having 100 amp TPN Aluminum bus bar of full length with base frame made out of 50x50x6mm thick angle iron having 150 mm legs duly erection in ground with construction of cement concrete complete with connection and interconnection with copper conductor PVC insulated cables / insulated copper conductor strip of appropriate size and terminals blocks (on outgoing) including supplying and fixing following switch gears & accessories there in powder coating, labeling, earthing etc. complete as required

-

-

-

... More
INCOMER

-

-

-

... More
1 no. 63 Amps 10 kA 4 MCB with thermal over load and magnetic short circuit releaes

-

-

-

... More
BUS BAR

-

-

-

... More
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 100 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 10 KA at 415 volts. The neutral busbar is to be of 100% capacity.

-

-

-

... More
INDICATING PANEL

-

-

-

... More
The incomers shall have the following indicating panel

-

-

-

... More
3 nos Cast resin current transformers of 63/5 ratio Class 1.0 for metering

-

-

-

... More
1 no ammeter of 96 mm sq scaled 0-63 amps with 3 way and OFF selector switch

-

-

-

... More
1 no voltmeter of 96 mm sq scaled 0- 500 volts with 3 way & OFF selector switch

-

-

-

... More
1 set of indicating lamps (ON. OFF)

-

-

-

... More
1 set of phase indicating lamps

-

-

-

... More
OUT GOINGS

-

-

-

... More
1 nos. 32 Amps 230 volt 10 kA 4P MCB with thermal magnetic protective releases.

-

-

-

... More
3 nos. 32 Amps 230 volt 10 kA DP MCB with thermal magnetic protective releases.

-

-

-

... More
1 nos 40 amp 10 kA 4P MCB with thermal magnetic protective releases with 40 amp TP Contactor with Dual setting 24 hour calibrated time switch for automatic operation of the supply, and 12 nos 6/10/16 amp SP 10 kA MCB's as outgoing.

-

-

-

... More
The Feeder Pillar shall be complete with all interconnections, busbars etc. complete as per design to be approved by the Architects.

1

77401

77401

... More
Cable & Termination

-

-

-

... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. UPPWD-501

-

-

-

... More
3.5 core 150 sq mm

180

957

172260

... More
3.5 core 120 sq mm

350

824

288400

... More
3.5 core 70 sq mm

100

613

61300

... More
4 core 25 sq mm

50

373

18650

... More
4 core 16 sq mm

300

343

102900

... More
4 core 10 sq mm

150

327

49050

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Based on DSR-9.1

-

-

-

... More
3.5 core 150 sq mm. Based on DSR-9.1.26

16

574

9184

... More
3.5 core 120 sq mm. Based on DSR-9.1.25

32

499

15996.8

... More
3.5 core 70 sq mm . Based on DSR-9.1.23

16

441

7056

... More
4 core 25 sq mm. Based on DSR-9.1.34

8

335

2683.2

... More
4 core 16 sq mm . Based on DSR-9.1.33

64

331

21209.6

... More
4 core 10 sq mm. Based on DSR-9.1.32

16

297

4764.8

... More
S/L of 160mm dia. DWC pipe for drawing of power cable across the road by drilling of 190mm dia. at 1mtr. Below the road level the work should be done by manual Trenchless method. Complete in all respect per direction of Engineer-in-charge YEIDA SOR-14

100

740

74000

... More
S/L of 200mm dia. DWC pipe for drawing of power cable across the road by driling of 230mm dia. at 1mtr. Below the road level the work should be done by manual Trenchless method. Complete in all respect per direction of Engineer-in-charge YEIDA SOR-15

100

796

79600

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duly)in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement: 2 fine sand) including trenching (75 cm deep) and refilling etc as required. Based on DSR-14.14.

-

-

-

... More
100 MM DIA. Based on DSR-14.14.1

30

443

13305

... More
150 MM DIA. Based on DSR-14.14.2

30

456

13689

... More
250 MM DIA. Based on DSR-14.14.3

70

634

44380

... More
Earthing

-

-

-

... More
Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. UPPWD-701

4

4076

16304

... More
Supply and burying of G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. UPPWD-703

16

5380

86080

... More
Supply and burying of copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. UPPWD-705

8

10450

83600

... More
Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect. UPPWD-718

160

1110

177600

... More
Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. UPPWD-717

320

150

48000

... More
Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect. UPPWD-716

150

90

13500

... More
Supply and fixing of one number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. UPPWD-721

500

200

100000

... More
Lightning Conductor

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate i ncluding holes etc. complete as required. Based on DSR-6.2

5

235

1175

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run). Based on DSR-6.7

150

522

78405

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) . Based on DSR-6.8

50

522

26135

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. Based on DSR-6.12

5

556

2783

... More
Earthing with G.I earth Plate 600 x 600 x 6 mm thick including accessories and providing mansory enlsoure with cover plate having locking arrangment and watering pipe of 2.7 metre long, with charcoal /coke and salt as required. Based on DSR-5.2

5

4141

20707

... More
Jointing copper /G.I. tape (with another copper/ GI tape, base of the finial or any other metallie object) by riveting /nut bolting/sweating and soldering etc as required. Based on DSR-6.4

2

47

94.2

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. Based on DSR-6.14

65

378

24589.5

... More
External Lighting & Poles

-

-

-

... More
Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. UPPWD-641

13

16500

214500

... More
Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. UPPWD-642

3

17100

51300

... More
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. UPPWD-1421 CAT- AAA

19

4940

93860

... More
Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. UPPWD-1442 CAT- AAA

28

4070

113960

... More
Supply & Fixing of XLPE insulated, Copper un-armoured Control cable 1100V grade etc. (A) 3 x 4 sq. mm. Based on DSR - 9.1.7

400

277

110840

... More
Supply & Fixing of XLPE insulated Aluminium un-armoured Cable. (A) 3 x 6 sq. mm. UPPWD-501

200

284

56800

... More
UPS SYSTEM

-

-

-

... More
Supply , installation, testing and commissioning of IGBT Rectifier & Inverter based UPS system comprising of 1 no 15 kVA units with battery bank backup of 30 minutes duration for full load with all standards fittings, accessories, protection, instruments, indications and controls including but not restricted to transformer, rectifire, inverter, SMF battery with float cum boost battery charger, static bypass switch, maintenance bypass, output isolation transformer, interconnections etc.including warranty and free all inclusive comprehensive maintenance services for two years for UPS and battery bank after the date of handing over complete as per specification and as required.

1

545201

545201

... More
\

-

-

22844799.7



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.