Yamuna Expressway Industrial Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Yamuna Expressway Industrial Development Authority - YEIDA Tender

Works
Eprocure
Opening Date21 Jan 2019
Closing Date26 Feb 2019
Tender Amount₹ 1,21,33,201 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
The breaking capacity specified for all MCCB's breakers is Ics value (service rating).

-

-

-

... More
Multifunction Meter having LED display accuracy Class 1 as per IEC 62053-21, RS-485 port, in built RTC, Aux Supply: 44-277Vac/dc. Parameters: Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh, Runhrs, Onhrs Interrupts, THD for V&I per phase, individual harmonics for V&I upto 15th level complying with IEC61557-12. Discrimination sheet shall be provided by contractor and Shop drawings shall be approved by architect.

-

-

-

... More
All Energy Analyser / TVM Shall have RS 485 Modbus RTU.

-

-

-

... More
Automatic Linear pneumatic Tube Detection based 4 Kg Novec 1230 System with DLP valve, push in connector for tube, 4Kg Novec 1230 gas, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation, 10-25 Mtrs Linear pneumatic heat Detection Tube with all necessary fittings & support and Master Control Unit with Audio Visual Alarm with wiring to make complete system operational. The Control Panel should have provision for integration with Fire Alarm/SCADA/BMS System. Makes : Firetrex /Sevo / UTC / Minimax

-

-

-

... More
GA drawings shall be got approved from Architects / Consultants before fabrication.The panel has to be specifically fabricated as per the space available at site. The existing column positions will also be considered.

-

-

-

... More
INCOMERS from 2 Nos. 500 KVA Transformers

-

-

-

... More
All the MCCBs shall be provided with potential free contacts for connectivity to PLC for ON/OFF status and control, as required, from BMC workstation. Thermal magnetic type upto 200 A and above 200A all MCCB shall be LSIG microprocesser based along with the speader terminals.

-

-

-

... More
All ACB's with full neutral and with variable overcurrent and short circuit releases & each complete with LSING Protection and Temperature base protection on the terminals

-

-

-

... More
INCOMER : 2 NOs 800 AMP FP EDO ACB 50KA

-

-

-

... More
Protection releases / relays, Metering & Accessories for each Transformer incomers

-

-

-

... More
Over Voltage / Under Voltage relay / release with timer.

-

-

-

... More
Backup earth fault relay.

-

-

-

... More
Restricted earth fault relay.

-

-

-

... More
Master trip relay.

-

-

-

... More
Trip Circuit Supervison relay.

-

-

-

... More
TNC switch.

-

-

-

... More
Auto manual selector switch.

-

-

-

... More
1 nos. 0-500 volt range digital type voltmeter with selector switch

-

-

-

... More
1 set of 3 CT's of ratio 800/5A, Class 1.0 accuracy 15 VA burden for metering.

-

-

-

... More
1 set of 3 CT's of ratio 800/5A, Class 1.0 accuracy 15 VA burden for APFCR.

-

-

-

... More
1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse.

-

-

-

... More
1 set of 4 CT's of ratio 800/1A, Class PS for protection.

-

-

-

... More
1 no. CT's of ratio 800/5A, Class 5P20 for protection.

-

-

-

... More
1 no. 0-630 Amp range digital type ammeter with selector switch.

-

-

-

... More
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.

-

-

-

... More
Frequency meter.

-

-

-

... More
Power Factor meter.

-

-

-

... More
1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing.

-

-

-

... More
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons.

-

-

-

... More
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.

-

-

-

... More
9 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares.

-

-

-

... More
Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop.

-

-

-

... More
Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps.

-

-

-

... More
D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out.

-

-

-

... More
1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (1010 KVA)

-

-

-

... More
Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same.

-

-

-

... More
The ACB and MCCB shall be electrically interlocked with the bus coupler and Transformer incomers with the help of PLC Syncronization.

-

-

-

... More
BUS BARS

-

-

-

... More
1 No of 1600 AMP , 415 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. The current density of bus bar shall be minimum 1.00 sq mm / amp.

-

-

-

... More
The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C.

-

-

-

... More
BUS COUPLER

-

-

-

... More
BUS COUPLER : 800 AMP FP EDO ACB 50KA

-

-

-

... More
Auto manual selector switch.

-

-

-

... More
1 nos. 0-500 volt range digital type voltmeter with selector switch

-

-

-

... More
1 set of 3 CT's of ratio 800/5A, Class 1.0 accuracy 15 VA burden for metering.

-

-

-

... More
1 set of 3 CT's of ratio 800/5A, Class 1.0 accuracy 15 VA burden for APFCR.

-

-

-

... More
1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse.

-

-

-

... More
1 set of 4 CT's of ratio 800/1A, Class PS for protection.

-

-

-

... More
1 no. CT's of ratio 800/5A, Class 5P20 for protection.

-

-

-

... More
1 no. 0-630 Amp range digital type ammeter with selector switch.

-

-

-

... More
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.

-

-

-

... More
Power factor meter.

-

-

-

... More
Frequency meter.

-

-

-

... More
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons.

-

-

-

... More
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB.

-

-

-

... More
INCOMERS from 2 Nos DG SET (250 KVA)

-

-

-

... More
INCOMER : 2 NO 630 AMP FP EDO ACB 50KA

-

-

-

... More
Protection releases / relays, Metering & Accessories for each D G set incomers

-

-

-

... More
Over Voltage / Under Voltage relay / release with timer.

-

-

-

... More
IDMT earth fault relay.

-

-

-

... More
Backup earth fault relay.

-

-

-

... More
Master trip relay.

-

-

-

... More
Trip Circuit Supervison relay.

-

-

-

... More
Reverse power relay.

-

-

-

... More
TNC switch.

-

-

-

... More
Auto / manual / test selector switch

-

-

-

... More
1 Set - 415 /v3 / 110 / v3 Volts PT Class 1.0 accuracy and 100 VA burden along with primary & secondary MCB.

-

-

-

... More
0-500 volt range digital type voltmeter with selector switch

-

-

-

... More
1 set - 3 CTs of ratio : 630/5A , Class 1.0 accuracy 15 VA each burden for metering.

-

-

-

... More
1 set - 3 CTs of ratio : 630/5A , Class 5P20 accuracy 20 VA each burden for protection.

-

-

-

... More
0-250 Amp range digital type ammeter with selector switch.

-

-

-

... More
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.

-

-

-

... More
Frequency meter.

-

-

-

... More
Power Factor meter.

-

-

-

... More
1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing.

-

-

-

... More
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons.

-

-

-

... More
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.

-

-

-

... More
9 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares.

-

-

-

... More
Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop.

-

-

-

... More
Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps.

-

-

-

... More
D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out.

-

-

-

... More
1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (1010 KVA)

-

-

-

... More
Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same.

-

-

-

... More
The ACB and MCCB shall be electrically interlocked with the bus coupler and Transformer incomers with the help of PLC Syncronization.

-

-

-

... More
BUS BARS

-

-

-

... More
1 No of 1600 AMP , 415 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. The current density of bus bar shall be minimum 1.00 sq mm / amp.

-

-

-

... More
The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C.

-

-

-

... More
BUS COUPLER

-

-

-

... More
BUS COUPLER : 800 AMP FP EDO ACB 50KA

-

-

-

... More
Protection releases / relays, Metering & Accessories for Bus Coupler (s)

-

-

-

... More
Trip circuit supervision relay

-

-

-

... More
TNC switch.

-

-

-

... More
Auto / manual selector switch

-

-

-

... More
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.

-

-

-

... More
The bus coupler shall be electrically interlocked with all incoming ACB's in such a way that at any one time two supply should not get mixed up.

-

-

-

... More
OUTGOINGS -

-

-

-

... More
All outgoing feeders shall be provided with one set of phase indication lamps and trip indication lamps with protection fuses/MCB and ammeter with selector switch with suitable ratio CT's of accuracy class 1.0

-

-

-

... More
9 nos. outgoing feeders shall be provided with electronic dual reading KWHR meter with RS 485 communication port, CT's with accuracy class 1, control circuits and wiring as per SLD.

-

-

-

... More
2 nos. 500 AMPS 3P MCCB 50KA. ( CAPACITOR PANEL)

-

-

-

... More
5 nos. 250 AMPS FP MCCB 50KA. ( FOR FLOOR METERING PANEL )

-

-

-

... More
1 nos. 250 AMPS FP MCCB 50KA. ( FOR BASEMENT PANEL )

-

-

-

... More
1 nos. 315 AMPS FP MCCB 50KA. ( FOR COMMON SERVICE PANEL)

-

-

-

... More
1 nos. 315 AMPS FP MCCB 50KA. (SPARE)

-

-

-

... More
2 nos. 250 AMPS FP MCCB 50KA. (SPARE)

-

-

-

... More
4 nos. 100 AMPS FP MCCB 50KA. (SPARE)

1

1870825

1870825

... More
AUTOMATIC POWER FACTOR CORRECTION PANEL (CAPACITOR PANEL)

-

-

-

... More
Supply , Installation, Testing commissioning, Design, manufacture, supply, inspection, handling, assembling, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type 175 KVAR A P F C Panel consisting of 100 / 50 / 25 KVAR capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 and IEC 61439-1&2 .

-

-

-

... More
All the MCCBs shall be provided with potential free contacts for connectivity to PLC for ON/OFF status and control, as required, from BMC workstation. Thermal magnetic type upto 200 A and above 200A all MCCB shall be LSIG microprocesser based along with the speader terminals.

-

-

-

... More
Capacitor duty contactors should be used for switching individual capacitor banks.

-

-

-

... More
The fault withstanding capacity of panel & its control gear shall be min. 35 KA rms for 1 sec. The capacitor panel shall be integrated with the main LT Panel as per schematic diagram

-

-

-

... More
Automatic Linear pneumatic Tube Detection based 2 Kg Novec 1230 System with DLP valve, push in connector for tube, 2Kg Novec 1230 gas, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation, 5-15 Mtrs Linear pneumatic heat Detection Tube with all necessary fittings & support and Master Control Unit with Audio Visual Alarm with wiring to make complete system operational. The Control Panel should have provision for integration with Fire Alarm/SCADA/BMS System(2 nos). Makes : Firetrex /Sevo / UTC / Minimax

-

-

-

... More
INCOMING

-

-

-

... More
Incomer circuit breaker has been included in the main panel.

-

-

-

... More
1 set- 3 CTs , ratio 600/5A Class 1.0 accuracy 15 VA burden for metering.

-

-

-

... More
1Nos- (0-600A) digital Ameter with selector switch

-

-

-

... More
Micro processor based automatic power factor control relay (including power factor meter) in 8 steps for automatic cut off or add on capacitor units to keep the power factor at 0.95 with variation of loads. All associated auxiliary contactors / relays shall be provided with in the scope of work.

-

-

-

... More
Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to indicate On/Off status of capacitor unit.

-

-

-

... More
BUS BARS

-

-

-

... More
630 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coding and insulated by heat shrinkable sleeves and clips on shrouds for joints. The current density of bus bar shall be minimum 1.00 sq mm / amp.

-

-

-

... More
The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above ambient temperature.

-

-

-

... More
OUTGOINGS -

-

-

-

... More
1 no. of 250 AMPS TPN 35 KA MCCB and 300 amps AC3 duty contactor with 100 KVAR gas filled 415 V capacitor bank, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete.

-

-

-

... More
1 no. of 125 AMPS TPN 35 KA MCCB and 150 amps AC3 duty contactor with 50 KVAR gas filled 415 V capacitor bank, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete.

-

-

-

... More
1 no. of 63 AMPS TPN 35 KA MCCB and 80 amps AC3 duty contactor with 25 KVAR gas filled 415 V capacitor bank, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete.

1

376365

376365

... More
Design, manufacture, supply, installation, testing and commissioning (COMMON SERVICES PANEL (FIRE FIGHTING , PLUMBING/STP , LIFT PANEL) of cubicle type panel fabricated out of 14 SWG CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts, 3 phase, 50 HZ complete and tested for internal arc or 35ka for 0.4 sec as per IEC 61439-1&2 with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears. Panels shall have 1-Phase and 3 Phase mertering space as per SLD.

-

-

-

... More
Supplying & fixing of following accessories in the existing cubical panel board / feeder pillar including connection testing and having provision for energy meter inside panel etc. as reqd.

-

-

-

... More
INCOMER : 315 AMP 4P MCCB (35 KA)

-

-

-

... More
OUTGOINGS -

-

-

-

... More
100 A,4-pole MCCB 35KA -- 1 no (PLUMBING/STP)

-

-

-

... More
160 A,4-pole MCCB 35KA -- 1 no (FIRE FIGHTING)

-

-

-

... More
100 A,4-pole MCCB 35KA -- 1 no (LIFT BOARD)

-

-

-

... More
63 A,4-pole MCCB 35KA -- 1 no (EXTERNAL LIGHTING)

-

-

-

... More
160 A,4-pole MCCB 35KA -- 1 no (SPARE)

-

-

-

... More
Indication lamps (RYB) LED type with protection MCB's - 1 set

-

-

-

... More
Danger notice plate -- 1 no

1

227689

227689

... More
FLOOR PANEL FOR GROUND FLOOR

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of 14 SWG CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts, 3 phase, 50 HZ complete and tested for internal arc or 25ka for 0.4 sec as per IEC 61439-1&2 with aluminium bus bar and all accessories including supply and fixing o following incoming and outgoing switchgears. Panels shall have 1-Phase and 3 Phase mertering space as per SLD.

-

-

-

... More
INCOMER:

-

-

-

... More
One no. 250A 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with selector switch, matching cast resin CT's.

-

-

-

... More
BUS BAR

-

-

-

... More
TPN Aluminium bus bar with heat Shrink Sleeve rated for 315A.

-

-

-

... More
OUTGOING

-

-

-

... More
26 nos 63 A 10 KA SPN MCB 10KA (Space for Metering)

-

-

-

... More
4 nos 63 A 10 KA TPN MCB 10KA

-

-

-

... More
Other items such as

-

-

-

... More
1 Set of control wiring

-

-

-

... More
1 Set of designation plates

-

-

-

... More
all items complete as above

1

141867

141867

... More
FLOOR PANEL FOR FIRST FLOOR

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of 14 SWG CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts, 3 phase, 50 HZ complete and tested for internal arc or 25ka for 0.4 sec as per IEC 61439-1&2 with aluminium bus bar and all accessories including supply and fixing o following incoming and outgoing switchgears. Panels shall have 1-Phase and 3 Phase mertering space as per SLD.

-

-

-

... More
INCOMER:

-

-

-

... More
One no. 250A 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with selector switch, matching cast resin CT's.

-

-

-

... More
BUS BAR

-

-

-

... More
TPN Aluminium bus bar with heat Shrink Sleeve rated for 315A.

-

-

-

... More
OUTGOING

-

-

-

... More
26 nos 63 A 10 KA SPN MCB 10KA (Space for Metering)

-

-

-

... More
4 nos 63 A 10 KA TPN MCB 10KA

-

-

-

... More
Other items such as

-

-

-

... More
1 Set of control wiring

-

-

-

... More
1 Set of designation plates

-

-

-

... More
All items complete as above

1

141867

141867

... More
FLOOR PANEL FOR SECOND FLOOR

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of 14 SWG CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts, 3 phase, 50 HZ complete and tested for internal arc or 25ka for 0.4 sec as per IEC 61439-1&2 with aluminium bus bar and all accessories including supply and fixing o following incoming and outgoing switchgears. Panels shall have 1-Phase and 3 Phase mertering space as per SLD.

-

-

-

... More
INCOMER:

-

-

-

... More
One no. 250A 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with selector switch, matching cast resin CT's.

-

-

-

... More
BUS BAR

-

-

-

... More
TPN Aluminium bus bar with heat Shrink Sleeve rated for 315A.

-

-

-

... More
OUTGOING

-

-

-

... More
12 nos 63 A 10 KA SPN MCB (Space for Metering)

-

-

-

... More
2 nos 63 A 10 KA TPN MCB

-

-

-

... More
Other items such as

-

-

-

... More
1 Set of control wiring

-

-

-

... More
1 Set of designation plates

-

-

-

... More
All items complete as above

1

104561

104561

... More
FLOOR PANEL FOR THIRD FLOOR

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of 14 SWG CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts, 3 phase, 50 HZ complete and tested for internal arc or 25ka for 0.4 sec as per IEC 61439-1&2 with aluminium bus bar and all accessories including supply and fixing o following incoming and outgoing switchgears. Panels shall have 1-Phase and 3 Phase mertering space as per SLD.

-

-

-

... More
INCOMER:

-

-

-

... More
One no. 250A 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with selector switch, matching cast resin CT's.

-

-

-

... More
BUS BAR

-

-

-

... More
TPN Aluminium bus bar with heat Shrink Sleeve rated for 315A.

-

-

-

... More
OUTGOING

-

-

-

... More
12 nos 63 A 10 KA SPN MCB (Space for Metering)

-

-

-

... More
2 nos 63 A 10 KA TPN MCB

-

-

-

... More
Other items such as

-

-

-

... More
1 Set of control wiring

-

-

-

... More
1 Set of designation plates

1

104651

104651

... More
FLOOR PANEL FOR FOURTH FLOOR

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of 14 SWG CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts, 3 phase, 50 HZ complete and tested for internal arc or 25ka for 0.4 sec as per IEC 61439-1&2 with aluminium bus bar and all accessories including supply and fixing o following incoming and outgoing switchgears. Panels shall have 1-Phase and 3 Phase mertering space as per SLD.

-

-

-

... More
INCOMER:

-

-

-

... More
One no. 250A 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with selector switch, matching cast resin CT's.

-

-

-

... More
BUS BAR

-

-

-

... More
TPN Aluminium bus bar with heat Shrink Sleeve rated for 315A.

-

-

-

... More
OUTGOING

-

-

-

... More
12 nos 63 A 10 KA SPN MCB (Space for Metering)

-

-

-

... More
2 nos 63 A 10 KA TPN MCB

-

-

-

... More
Other items such as

-

-

-

... More
1 Set of control wiring

-

-

-

... More
1 Set of designation plates

-

-

-

... More
All items complete as above

1

104651

104651

... More
Design, manufacture, supply, installation, testing and commissioning BASEMENT PANEL of cubicle type panel fabricated out of 14 SWG CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts, 3 phase, 50 HZ complete and tested for internal arc or 25ka for 0.4 sec as per IEC 61439-1&2 with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears. Panels shall have 1-Phase and 3 Phase mertering space as per SLD.

-

-

-

... More
Supplying & fixing of following accessories in the existing cubical panel board / feeder pillar including connection testing and having provision for energy meter inside panel etc. as reqd.

-

-

-

... More
INCOMER : 250 AMP 4P MCCB (35 KA) (Space for Metering)

-

-

-

... More
OUTGOINGS -

-

-

-

... More
63 A, TPN MCB -- 10 no

-

-

-

... More
100A,4-pole MCCB -- 3 no (VENTILATION)

-

-

-

... More
100 A,4-pole MCCB -- 1 no (SPARE)

-

-

-

... More
Indication lamps (RYB) LED type with protection MCB's - 1 set

-

-

-

... More
Danger notice plate -- 1 no

-

-

-

... More
Other items such as

-

-

-

... More
1 Set of control wiring

-

-

-

... More
1 Set of designation plates

-

-

-

... More
All items complete as above

1

173844

173844

... More
LIFT PANEL

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of 14 SWG CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts, 3 phase, 50 HZ complete and tested for internal arc or 25ka for 0.4 sec as per IEC 61439-1&2 with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears.

-

-

-

... More
INCOMER:

-

-

-

... More
One no. 100A 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with selector switch, matching cast resin CT's.

-

-

-

... More
BUS BAR

-

-

-

... More
TPN Aluminium bus bar with heat Shrink Sleeve rated for 160A.

-

-

-

... More
OUTGOING

-

-

-

... More
3 nos 63 A TPN MCB

-

-

-

... More
1 nos 40 A DP MCB

-

-

-

... More
Other items such as

-

-

-

... More
1 Set of control wiring

-

-

-

... More
1 Set of designation plates

-

-

-

... More
All items complete as above

1

83243

83243

... More
EXTERNAL LIGHTING FEEDER

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of Outdoor type IP-67 waterproof panel fabricated out of 14 SWG CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts, 3 phase, 50 HZ complete and tested for internal arc or 25ka for 0.4 sec with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears.

-

-

-

... More
INCOMER:

-

-

-

... More
One no. 100A 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with selector switch, matching cast resin CT's.

-

-

-

... More
BUS BAR

-

-

-

... More
TPN Aluminium bus bar with heat Shrink Sleeve rated for 160A.

-

-

-

... More
OUTGOING

-

-

-

... More
3 nos 63 A 4P MCB WITH TIMER

-

-

-

... More
4 nos 40 A DP MCB WITH TIMER

-

-

-

... More
3 nos 63 A 4P MCB

-

-

-

... More
4 nos 40 A DP MCB

-

-

-

... More
Other items such as

-

-

-

... More
1 Set of control wiring

-

-

-

... More
1 Set of designation plates

-

-

-

... More
LT CABLES

-

-

-

... More
Supply and Laying of aluminium conductor PVC/ XLPE insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S clamps etc of suitable size or as directed by the Engineer - INcharge. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.

-

-

-

... More
16 sq. mm 4 core

100

25400

254

... More
25 sq. mm 3-1/2 core

100

27100

271

... More
50 sq. mm 3-1/2 core

150

55800

372

... More
95 sq. mm 3-1/2 core

120

65040

542

... More
120 sq. mm 3-1/2 core

190

123500

650

... More
150 sq. mm 3-1/2 core

250

187250

749

... More
300 sq. mm 3-1/2 core

584

781392

1338

... More
Supply and fixing of brass nickle plate compression gland for PVC/ XLPE insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge.

-

-

-

... More
16 sq. mm 4 core

8

656

82

... More
25 sq. mm 3-1/2 core

8

736

92

... More
50 sq. mm 3-1/2 core

12

1644

137

... More
95 sq. mm 3-1/2 core

8

1312

164

... More
120 sq. mm 3-1/2 core

18

2952

164

... More
150 sq. mm 3-1/2 core

12

2460

205

... More
300 sq. mm 3-1/2 core

20

7800

390

... More
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer Incharge

-

-

-

... More
16 sq. mm 4 core

8

136

17

... More
25 sq. mm 3-1/2 core

8

192

24

... More
50 sq. mm 3-1/2 core

12

552

46

... More
95 sq. mm 3-1/2 core

8

792

99

... More
120 sq. mm 3-1/2 core

18

2268

126

... More
150 sq. mm 3-1/2 core

12

1944

162

... More
300 sq. mm 3-1/2 core

20

9000

450

... More
CABLE TRAY

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

200

69600

348

... More
150 mm width X 50 mm depth X 1.6 mm thickness

60

23580

393

... More
300 mm width X 50 mm depth X 1.6 mm thickness

150

78900

526

... More
450 mm width X 50 mm depth X 2.0 mm thickness

20

15640

782

... More
600 mm width X 50 mm depth X 2.0 mm thickness

100

95000

950

... More
MISCELLANEOUS ITEMS - DSR

-

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm x 150 mm made of mild steel, at least 2 mm thick and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required .

6

894

149

... More
Providing and fixing H.T. danger notice plate of 250 mm x 200 mm made of mild steel, at least 2 mm thick and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required .

2

326

163

... More
EARTHING AND LIGHTING PROTECTION-DSR

-

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

640

82560

129

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

560

20720

37

... More
EARTHING AND LIGHTING PROTECTION-NON DSR

-

-

-

... More
Data Sheet shall be approved by architect

-

-

-

... More
SITC of fully autonomous Early Streamer Emission Lightning Air Terminal (ESEAT) comprising of floating panels/body isolated from an earthed central finial/tip (elevated sharp tip) on top of the highest point to protect from direct lightning strikes with the following technical parameters. As per NF C 17-102:2011 standard (Annexe C), Clause C.3.4 - the ESE air terminal should be tested for an Impulse current (10/350 micro sec)=100 KA (+ 10%), Charge (Q)=50 A.s (+ 20%), Specific Energy (W/R)=2500 KJ/Ω (+ 35%) and as per Clause C.3 all the tests should be carried out on a sample (preferably all tests in one lab) according to the flow chart in figure C.1 (Sequence of testing). As per Clause C.3.5.2.3.4, the ese air terminal shall be tested for 50 impulse and recorded for delta T (Triggering time advance). For the local certification, the ESE air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) or more. The international testing laboratory should be duly accredited by ILAC / IEC / ENAC / EZU / UL to ensure the genuine testing and the quality of the product and the ese air terminal should be supplied along with the country of origin certificate as per detailed technical specification attached. Make-LPI / Erico / DEHN

-

-

-

... More
ESE air terminal of delta T (ΔT) = 50 micro seconds (Protection radius = 68 mtrs @ Level I / Very High) Make-LPI / Erico / DEHN

1

126519

126519

... More
SITC of highly insulated polyplastic adaptor to fix the lightning ese air terminal with the mast. The adaptor shall have suitable metal connector/connecting point in such a way the top portion shall be electrically connected to the central finial/tip (elevated sharp tip) of the ese air terminal and the bottom portion shall be connected to the down conductor as per technical specification attached. Make-LPI / Erico / DEHN

1

5720

5720

... More
SITC of mast of GI pipe of 5 mtrs long 50 mm dia with base plate along with the guy wire kit (18 mtrs) to fix the ese air terminal as per detailed technical specification attached. Make-LPI / Erico / DEHN

1

7123

7123

... More
SITC of Lightning Strike Recorder - 7 digits electro mechanical display to record the lightning current in an IP 67 enclosure with the minimum sensitivity of 1500A (8/20 micro second waveform). The recorder should be of non-resettable type with the electro-mechanical display and no LCD screen is permitted as it may depend upon the battery life to energize the LCD. The lightning strike recorder shall be tested and certified as per IEC 60-1:1989 standard inline with the lightning arrester for an impulse current of more than 400 KA (8/20 micro second) as per technical specification attached. Make-LPI / Erico / DEHN

1

28160

28160

... More
SITC of 70 sq mm pvc insulated copper flexible cable for down conductor including fixing of suitable clamps and other accessories from the ese air terminal to the earth pit as per detailed technical specification attached. Make-LPI / Erico / DEHN

25

20275

811

... More
SITC of non corroding weather proof water proof polycarbonate/polystyrene IP 65 / IP 55 (with glands) enclosure (in accordance with IEC 60670-22 standard) including providing of 2 numbers of insulated supports, 25 x 3 mm thick copper strip with suitable holes prefitted SS bolt & nuts to fix the down conductor & earth wire. The dimension shall be of minimum 160 mm (W) x 120 mm (H), 80 mm (D) duly certified by VDE / UL as per detailed technical specification attached. Make-LPI / Erico / DEHN

1

4318

4318

... More
SITC of Tripod advance chemical gel earthing system of 03 numbers of any UL listed & CPRI tested 10 feet long 25 mm dia 250 microns copper bonded steel rod along with 60 Kgs (20 Kgs or more per pit) or more quantity of resistance lowering grounding minerals, well interconnected with sutiable copper strip to form a triangle shape (distance between the rods shall be the length of the rod). The UL listed copper bonded rod should be tested & ceritifed from a local body CPRI for a short circuit current of 50 KA or more. The UL listing shall be marked on the rod for the physical verification at site. The markings shall be of UL Control number, Dimension details of the rod, Product model number & UL certificate reference number. As per IEEE 80-2013 (Clause 14.5 d), the grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr. Also the compound shall be tested in compliance with the international standard IEC 62561-7. The grounding minerals should be ROHS certified to ensure it does not pollute the ground water. Each earth pit shall be covered with suitable heavy duty weather proof environment friendly polyplastic earth pit chamber with cover of auto-locking facility and tested from any Govt of India laboratory for 9 tons load bearing capacity with the following dimensions - 254 mm dia (top), 330 mm dia (bottom) and 260 mm (height). 4 knock-out openings are provided for the easy interconnection of earth strips between the earth pits to form a grid as per technical specification attached. Make-LPI / Erico / DEHN

16

595760

37235

... More
INTERNAL LIGHTING FIXTURES & FANS

-

-

-

... More
Supply, installation, testing and commissioning of 2 * 18 watt T8 Surface mounted LED light fixture similar to Bajaj Cat. Ref. No : BLRB-DB 218 including 2X18W LED Tube Light or equivalent.

65

120445

1853

... More
Supply, installation, testing and commissioning of 18 watt LED Baton Surface/Wall mounted light fixture similar to Bajaj Cat. Ref. No : BCLSB 18WH or equivalent.

19

10431

549

... More
Supply, installation, testing and commissioning of 10 watt LED Baton Surface/Wall mounted light fixture similar to Bajaj Cat. Ref. No : BCLSB 10WH or equivalent.

20

8620

431

... More
Supply, installation, testing and commissioning of 12 watt LED Light similar to Bajaj Cat. Ref. No :BGSLO Sleek Surface 12W RD or Equivalent.

65

60320

928

... More
Supply, installation, testing and commissioning of 18 watt LED Light similar to Bajaj Cat. Ref. No :BGSLO Sleek Surface 18W RD or Equivalent.

110

134420

1222

... More
Supply, installation, testing and commissioning of 10W BULK HEAD LIGHT as per Bajaj cat no: BIBWP 10W LED or equivalent.

39

55848

1432

... More
SUPPLY OF CEILING & EXHAUST FANS

-

-

-

... More
Supply, installation, testing and commissioning of AC 230/250 volts, 50 HZ ceiling fan with standard down rod, blades, 2 nos. caps, Copper Windings & regulator etc. ISI marked complete as required.

-

-

-

... More
1200 mm sweep ( as per havells model no : ES-50 premium 5* )

1

2108

2108

... More
Supply, installation, testing and commissioning of AC 230/250 volts, 50 HZ exhaust fans including providing nuts, bolts, mounting frame, Copper Windings and other accessories etc. complete

-

-

-

... More
(Make : Bajaj / Crompton / Havells)

-

-

-

... More
300 mm sweep 900 rpm ( as per havells model no :Turbo force single phase)

22

65252

2966

... More
Supply, installation, testing and commissioning of AC 230/250 volts, 50 HZ Wall fan with standard down rod, blades, 2 nos. caps, Copper Windings & regulator etc. ISI marked complete as required. 400 mm sweep ( as per havells model no : Swing )

-

-

-

... More
EXTERNAL LIGHTING SYSTEM

-

-

-

... More
Supply, installation, testing and commisning of Ring Shape LED post top lantern, Die cast aluminium graphite grey powder coated finished housing.Polycarbonate opal diffuser.Low powder LEDS connected in series and parallel combination with better heat dissipation arrangement.Highly efficient constant current electronic driver having operating voltage range from 140-280 Volt AC; provided with high voltage, open and short circuit protection.Suitable for 60mm OD pipe entry with fixing bolts. (Lumens 3388) Degree of protection IP 65.Led colour temperature- 3000°K ± 300 °K. THD 10% & Voltage surge protection 5KV with suitable support and acessiories as required with 1-3 meter GI pole complete with all accessories as per Drawings.. (BAJAJ:- BGCP 45W LED)/ PHILIPS

6

-

-

... More
Supply, installation, testing and commisning of 60W LED street light with pressure die cast aluminium housing & toughfned glass with IP-66 degree of protection, Individual LED's must have lenses for better throw across & along the road ,with luminaire effcacy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 75 and co-related colour temperature (CCT ) of 5700K (± 300K) , The luminaire should have 10KV surge protection, PF ≥ 0.9, and total harmonic distortion of THD ≤ 10% , voltage range of 140-280V should be provided. Luminaire should have top maintanable driver compartment for easy access to driver during maintenence. The Driver used must be a constant current driver with efficiency of ≥ 85% The manufacturers LOGO must be embossed into the housing of the luminaire. Manufacturers to provide LM 79 and LM80 Reports to be submitted from NABL accredited Lab to ensure above parameters. Bajaj : BRTFG 60W LED/ PHILIPS

12

-

-

... More
Supply, installation, testing and commisning of 6 meter octagonal pole with top dia 70mm, bottom 130mm having sheet thickness 3mm and base plate of size 200 x 200 x 12mm thick The welding will be done as per BS 5135 / IS 9595. No circumferential welding shall be allowed in the pole shaft. The MS shall conform to BSEN 100025/100027. The structure shall be single hot dip galvanized as per BS 729 / IS 2629. A suitably designed door shall be provided at approximate 500mm height from the pole base. The door opening will be suitably reinforced for structural strength. The door shall be flushed with pole external surface and shall provide easy access for electrical connections at a maintainable height with foundation bolts of size M 20x 600mm long manufactured from special steel along with nuts, washers, anchor plate and template along with 1 meter long single arm bracket suitable for above mentioned pole with 63 Amp terminal block suitable for 25/50 Sq.mm conductor - 4 nos. and fixing DIN channel of suitable length - 2 Nos. on the existing laminated sheet and 10 Amp. SPMCB 'C' series - 1 No. for each light with 3 core 2.5 sq.mm of suitable size as per Bajaj/ Philips. (Pole shall be complete with all arrangement required solar or General lights and Pole design shall be approved by architect)

12

-

-

... More
11KV HT VCB PANEL

-

-

-

... More
Design, comply to IEC 62271-100/200 ,Supply, Installation, Testing and Commissioning of One incoming, Two outgoing,indoor type, 1250 A, 11KV, 3 Phase, 50 Hz, earthed, 350 MVA fault level Vacuum Circuit Breaker motor operated, expandable type , type tested design un-pained with Alu - Zinc coated sheet steel however doors/covers will be CRCA painted, fully Interlocked, Indoor industrial pattern, Metal clad, Horizontal isolation,Horizontal drawout, floor mounting, earthing trolley for cable and bus, copper bus bar with heat shrink sleeves.The switchboard shall be suitable for short time current of 25KA for 3 sec, Internal Arc AFLR of 25kA for 1 sec, All major sub components should be of same make.Manufacturer must carry out testing of the panel at Authorized testing lab as approved by Architect. VCB panel as per inspected by Electrical Consultant /Architect at manufectureing Plant.

-

-

-

... More
Automatic Linear pneumatic Tube Detection based 4 Kg Novec 1230 System with DLP valve, push in connector for tube, 4Kg Novec 1230 gas, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation, 10-25 Mtrs Linear pneumatic heat Detection Tube with all necessary fittings & support and Master Control Unit with Audio Visual Alarm with wiring to make complete system operational

-

-

-

... More
INCOMER : - 1 NO each equipped with the following :

-

-

-

... More
Vacuum Circuit Breaker

-

-

-

... More
11KV 630A 3P 350MVA

-

-

-

... More
Current Transfomer-

-

-

-

... More
CR CT 11KV 300/5A 30VA Core-1 CL:0.5, Core-2 CL :5P10, Core-3 CL:PS

-

-

-

... More
Potential Transformer-

-

-

-

... More
CR CT 11/1.732KV / 110/1.732V , 100VA , Core-1 CL:0.5 & Core-2 CL:3P , 50HZ, with all accessories

-

-

-

... More
Relays-

-

-

-

... More
IDMT 3 O/C + 1 E/F RELAY

-

-

-

... More
Over voltage relay

-

-

-

... More
Under voltage relay

-

-

-

... More
Restricted earth fault relay

-

-

-

... More
Master trip relay

-

-

-

... More
METERS-

-

-

-

... More
Digital Ammeter with selector switch (0-300A)

-

-

-

... More
Digital Voltmeter with selector switch (0-15KV)

-

-

-

... More
Multi function digital meter

-

-

-

... More
Set of indication Lamps-

-

-

-

... More
Red-ON

-

-

-

... More
Green-OFF

-

-

-

... More
White-Trip Circuit Healthy

-

-

-

... More
Amber-Trip Condition

-

-

-

... More
Set of wiring, Ferrules & Fuses Power-Pack 110/24V DC Supply for simultaneous tripping of three breakers.

-

-

-

... More
BUSBAR-

-

-

-

... More
800A TP 11KV CU. Busbars with heat shrinkable insulation sleeves

-

-

-

... More
OUTGOING :- 2 Nos each equipped with the following:

-

-

-

... More
Vacuum Circuit Breaker

-

-

-

... More
11KV 630A 3P 350 MVA

-

-

-

... More
Current Transfomer-

-

-

-

... More
CR CT 11KV 200/5A 15VA Core-1 CL:0.5, Core-2 CL:5P10

-

-

-

... More
Potential Transformer-

-

-

-

... More
Ratio: 11KV/110V

-

-

-

... More
Relays-

-

-

-

... More
IDMT 3 O/C + 1 E/F RELAY

-

-

-

... More
Master trip relay

-

-

-

... More
METERS-

-

-

-

... More
Digital Ammeter with selector switch

-

-

-

... More
Digital Entergy meter

-

-

-

... More
Multi Function Digital Meter

-

-

-

... More
Set of indication Lamp-

-

-

-

... More
Red-ON

-

-

-

... More
Green-OFF

-

-

-

... More
White-Trip Circuit Healthy

-

-

-

... More
Amber-Trip Condition

-

-

-

... More
Set of wiring, Ferrules & Fuses.

-

-

-

... More
Suitable Battery and Charger Unit

-

-

-

... More
ALL ITEMS COMPLETE AS ABOVE

1

1146695

1146695

... More
TRANSFORMER (11 KV /0.4 KV) (500 KVA)

-

-

-

... More
Supply, storing, inspection, handling, assembling, installing in correct aligned position effecting proper connections, testing & commissioning of Outdoor type 11 KV / 433 Volt Transfomer Oil Type, 3 phase , Dyn 11 vector group, 50 cycles, (ONAN) Oil Cooled, step down, copper wound, continuous duty, temperature rise 90oC Insulation Class A as per IS: 1180 Level-I or updated..

-

-

-

... More
Civil work shall be paid extra as per actual. All Testing & Inspection shall be done in the presence of Electrical Consultant/ Architect at manufectures plant.

-

-

-

... More
Transformer shall be double wound, core type with low loss, non ageing ,high permeability PRIME GRADE , CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Bidder should have in-house Core Cutting facility for proper monitoring `and Control on quality and also to avoid any possibility of mixing prime material with defective /second grade material. Foil winding for LV winding for better SC withstand strength (as there will not be any axial forces and minimal radial forces.)

-

-

-

... More
ON Load Tap Changer on HV side + 5% to - 15% @ 2.5% per step/ as per IS:1180 with position indicator and locking arrangements or as approved by Architect.

-

-

-

... More
STANDARD FITTINGS AND ACCESSORIES

-

-

-

... More
01. Rating and diagram plate One

-

-

-

... More
02. Earthing terminals Two

-

-

-

... More
03. Lifting Lugs Four

-

-

-

... More
04. On Circuit Tap Links One & O.T.I with Alarm & Trip Contacts, OLTC surge relay

-

-

-

... More
05. Separate Neutral Bushing One, Cable Termination box for 11 KV 3C-240 sq mm XLPE cable

-

-

-

... More
06. HV Cable Box & Conservator with Oil filling hole with cap

-

-

-

... More
07. LV Bus duct / cable box One

-

-

-

... More
08. Bi – directional roller Four

-

-

-

... More
09. Winding Temperature Indicator (Scanner Type) One

-

-

-

... More
10. Marshalling Box One & Raiting Plate

-

-

-

... More
11. M.S. Enclosure One

-

-

-

... More
No Load Losses - 2000 Watts + IS Tol.

-

-

-

... More
Load Losses - 9500 watts + IS Tol.

-

-

-

... More
IP Protection - As per IS1180 (Outdoor Type)

-

-

-

... More
Paint Shade - Epoxy & Polyurethane Paint etc

-

-

-

... More
Applicable Standard : IS : 1180 Level-I or Higher.

-

-

-

... More
GA drawings shall be approved from Architects / Consultants before fabrication.The Transformer shalls be inspected by Electrical Consultant / Architect in their manufacturing plant.

-

-

-

... More
500 KVA

1

1376716

1376716

... More
250 KVA DG SET

-

-

-

... More
Design, Manufacture, Supply, installtion, testing and commissioning at site of 250 KVA /200KW radiator cooled, silent DG Set comprising of Standred BHP Diesel Engine @ 1500 rpm & 250 KVA Alternator rated at 3-phase, 415 Volts, 50Hz; 0.8 pf, both mounted and aligned on a common MS base frame complete with MS Fuel Tank, Generator Control Panel, Standrad AMF Panel, Residential Exhaust Silencer, AVM Pads fitted on base frame, Minimum 2 nos. 12 Volts, 100 AH Battery, Battery Leads, 1st fill of lube oil, all housed in Sound Proof Acoustic Enclosure complete as required:

-

-

-

... More
GA drawings with Data Sheet shall be got approved from Project Consultant/ Electrical Consultants before fabrication. All Items shalls be inspected by Project / Electrical Consultat in their manufacturing plant.

-

-

-

... More
Diesel Engine

-

-

-

... More
CPCB-2 Norms compliant, 6-Cycle, Radiator Cooled, Standred BHP Diesel Engine @ 1500 RPM, Turbocharged and Low Temperature Aftercooled complete with following as required:

-

-

-

... More
Flywheel with Starter Ring for Generating Set.

-

-

-

... More
Dry type air filter

-

-

-

... More
Lube oil cooler Assembly with accessories

-

-

-

... More
Exhaust air manifold

-

-

-

... More
Exhaust Silencer

-

-

-

... More
Expansion bellow.

-

-

-

... More
Exhaust gas turbocharger

-

-

-

... More
Fuel filters (pre and macro).

-

-

-

... More
Lube oil filter (Spin On type).

-

-

-

... More
Radiator with pusher type fan, with fan guard, coolant pump

-

-

-

... More
24V electrical starting system with starter motor and battery charging alternator

-

-

-

... More
In-line monoblock Fuel Injection Pump with governor and fuel feed pump.

-

-

-

... More
12 cylinders, Vertical or In-Line Shape

-

-

-

... More
Front & Rear engine mounting supports.

-

-

-

... More
Engine control panel consisting of OFF/ON/START keys, Lube Oil Pressure Gauge, Ammeter, Electronic Hour Meter, Coolant Temperature Gauge.

-

-

-

... More
Safeties against Low Lube Oil Pressure & High Coolant Temperature.

-

-

-

... More
Engine Operation/Maintenance & Spare parts Manual

-

-

-

... More
Loading permitted 110% for 1 hr once in every 12 hrs.

-

-

-

... More
Engine Warranty Certificate.

-

-

-

... More
Engine test certificate.

-

-

-

... More
Alternator

-

-

-

... More
250 KVA, 415 Volts, 3 Phase, 0.8 p.f. (lag), 1500 RPM, in accordance with IS 4722 & as per following specifications:

-

-

-

... More
Type: Salient pole, brush less type, suitable for direct coupling to engine.

-

-

-

... More
Voltage Regulation: Provided with fast response thyristor type electronic automatic voltage regulator, which holds output voltage within desired limits. (+/- 1%)

-

-

-

... More
Overspeed capability – 150% for 30 seconds

-

-

-

... More
Excitation: Brushless type, self excited, self regulated.

-

-

-

... More
Alternator Loading: Suitable for taking rated load immediately after machine reaches rated voltage and speed.

-

-

-

... More
Vibration: Suitable for direct coupling with Engine and mounted on common M.S. Channel base frame.

-

-

-

... More
Enclosure: Screen protected drip proof enclosure with IP - 23 degree of protection.

-

-

-

... More
Cooling: Air cooled type with radial fan mounted on Rotor.

-

-

-

... More
Winding Insulation: Class 'H'.

-

-

-

... More
Essential Accessories

-

-

-

... More
One set of essential accessories shall be supplied with each DG set. This set of accessories shall comprise of the following:

-

-

-

... More
One No. MS Base Frame suitable for mounting of the offered engine and alternator.

-

-

-

... More
One No. Day fuel tank of 990 litres capacity complete with fuel gauge, inlet/outlet connections, drain plug, etc or as per OEM.

-

-

-

... More
24 V DC starting system comprising of starter motors, voltage regulator and arrangement of initial excitation complete with 2 nos. 12 V each lead acid type batteries as per OEM standard as required.

-

-

-

... More
Supply, Fixing, testing and Commissioning of exhaust piping with structural support (Upto 5000kg/ 30 meter as per CPCB-II guidelines) for support of horizontal & vertical exhaust piping in the open including fabrication, hardwares and painting shall be including in DG set cost.

-

-

-

... More
1 Set of AVM Pads fitted on Base Frame.

-

-

-

... More
1 nos standrad AMF panel as per OEM with IP65 raiting (optional gaskit), control signal for auto transfer b/w mains and generator.

-

-

-

... More
Specifications Of Sound Proof Enclosure

-

-

-

... More
Construction :

-

-

-

... More
The container should be designed for easy access to serviceable parts.

-

-

-

... More
Modular construction for easy assembling and dismantling.

-

-

-

... More
Fabricated out of CRCA sheet of 14SWG. Base frame should be made out of ISMC of suitable sections or made out of sheet steel of minimm thickness 4 mm.

-

-

-

... More
The hardware should be high tensile grade i.e. bolts of 10.9/8.8 grade. Hardware should be of SS or Electro ZN plated.

-

-

-

... More
Fuel Tank should be fitted in the base frame having capacity of min. 900 ltrs, fitted with breather and all other necessary assemblies.

-

-

-

... More
The fuel level measurable through a mechanical fuel gauge.

-

-

-

... More
There should be provision for filling the fuel from inside the enclosure

-

-

-

... More
In case of integral Fuel tank, connected to engine with flexible fuel pipes.

-

-

-

... More
Batteries should be accommodated in a separate tray in the container.

-

-

-

... More
There should be provision for drain plugs for draining mobile oil/ diesel.

-

-

-

... More
The doors should be gasketed with high quality EPDM gaskets to avoid leakage of sound. The door handles should be lockable type.

-

-

-

... More
1x100 Ltrs Automatic Low Pressure Water Mist Fire detection and suppression system, Including 100 ltr Water storage tank made os Stainless Steel grade 304, Nitrogen pressurized Cylinder, Stainless Steel Schedule 5 Seamless Piping, C-EL Electric Actuator, ,NRV, strainer Low pressure water mist nozzle(FM Approved) 4 Nos, instruments( Pressure regulator, pressure gauge, pressure switch, levele switch), CEL panels, piping supports, release system, control cable system supplied & design calculation including Intrinsically safe Probe Type Heat Detector,Release Panel, Manual release & Abort system complete in all respect. Makes : VID Fire Kill / Viking / Minimax

-

-

-

... More
Painting :

-

-

-

... More
The sheet metal components should be hot dip seven tanks pre-treated.

-

-

-

... More
To have long life of container it should be P.P. based powder coated (inside as well outside)

-

-

-

... More
Base frame should be epoxy coated when fabricated.

-

-

-

... More
Acoustic Insulation:

-

-

-

... More
Sound proofing of enclosure should be done with quality rock wool/mineral wool confirming to IS-8183 of 64/96 Kg/m3 density.

-

-

-

... More
The rock wool/ Glass wool should be further covered with fiber glass cloth/fiber tissue paper fire resistive and perforated powder coated sheet of 0.6mm thickness.

-

-

-

... More
Hospital silencer should be provided to control exhaust noise.

-

-

-

... More
Interconnection between silencer and engine should be through stainless steel flexible hose/ pipe.

-

-

-

... More
Attenuators should be provided to control sound at air entry to the container and exit from the container.

-

-

-

... More
Ventilation & Air Circulation :

-

-

-

... More
The system should be designed to provide air inlet/exhaust acoustic louvers for efficient air circulation and having following special features :

-

-

-

... More
Adequate ventilation should be provided to meet air requirement for combustion and heat removal.

-

-

-

... More
The temperature inside the enclosure limited to 5-7°C over and above ambient temperature near air suction point.

-

-

-

... More
Provision for Neutral/ Body Earthing:

-

-

-

... More
Points should be available at side of the enclosure with the help of flexible copper wires from alternator neutral, and electrical panel body respectively. The Neutral earthing point should be isolated through DMC insulator mounted on enclosure.

-

-

-

... More
Engine Panel should be mounted in the container itself. All parameters should be visible from outside and all operation buttons shall be accessible easily.

-

-

-

... More
ALL ITEMS COMPLETE AS ABOVE

2

-

-

... More
ADDRESABLE FIRE ALARM SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of following as per specifications : (Make-Bosch, siemens fire finder, Grambell)

-

-

-

... More
Microprocessor based Inteligent and electronically addressable, modular, Expandable networkable. 3 loops Panel Panel with each loop capacity of 250 Devices at any combinations, loop lenght up to 3 KM. Fire alarm control panel WIth 5.7 inch touch screen LCD display, multiple acces levels, 10,000 event history logs in the non volatile memory (EEPROM). The panel should be modular microprocessor Based In natureand should be expandable from single loop up tc 32 loops. The panel shal! have 240V AC power supply. Autornantic battery charger, 24V . shield lead acid maintenance free battries sufficient for 24 houres normal working and then be capable of cperatlng the system for 30mins during emergency condtion . provision for integration to BMS Backnet software . The panel shall be EN-54/VDS / UL certification, Shop Drawings shall be approved by architect. (Make-Bosch, siemens fire finder, Grambell)

1

329575

329575

... More
Active Repeater panel with minimum 640 Character LCD display complete system function keys for programming and control like system reset, Alarm Acknowledge, Alarm Silence, Trouble Acknowledge etc. as per specification .The panel shall be EN-54/VDS / UL certification (Make-Bosch, siemens fire finder, Grambell)

4

310464

77616

... More
Addresable monitor module with 2 monitoring features . Monitoring Of with EOL restore Potential free contact & voltage monitoring shlla be EN54/VDs/UL Certifications . (Make-Bosch, siemens fire finder, Grambell)

5

24255

4851

... More
Addressable Control realy modules with flexible network with maximum switching corrent of 1A @30V DC shall be EN54/VDs certification/UL

5

24255

4851

... More
Addressable Heat Detector withfixed and rate of raise including mountions base with LED. Etc. complete with require 2 isolater ( one for incoming and one for outgoing line ) integared in detector for maintaining operational availability of all elements inthe loop even in the event of a shor circuit & Drift compenstion features & automatic addessing . FAP-425-DOT-R High resitence to electromagnetic effects in accordable with EFSG Agreement EFSG/ F/ 97/ 005 shall be EN54/VDs/UL Certification (Make-Bosch, siemens fire finder, Grambell)

39

126126

3234

... More
Addressable detector with two optical sensors,one thermal and one chemical sensor, manually and automatically with dual ray technology including mountions base with LED. Etc. FAP-425-DOTC-R complete with require 2 isolater ( one for incoming and one for outgoing line) integared in detector for maintaining operational availability of all elements inthe loop even in the event of a shor circuit & Drift compenstion features & automatic addessing shall be EN54/VDs/UL Certification.

1

5660

5660

... More
Addressable multisensor Smoke+Thermal detector with suitable technology including motions base with LED. Etc. complete with require 2 isolater ( one for incoming and one for outgoing line ) integared in detector for maintaining operational availability of all elements inthe loop even in the event of a shor circuit & Drift compenstion features & automatic addessing shall be EN54/VDs/UL Certification. (Make-Bosch, siemens fire finder, Grambell)

206

1165960

5660

... More
Supply , installtion , testing and commssioning of addressable invisible detector for smoke optical component for flush fitting in steel reinforced concrete ceiling or suspended ceilings having a detection principle of two independent scattering light sensor with sensing volumes directly beneath the detector with feature of drift compensation , contamination detection by means of thired optcal system , protection againest insect by means of dual evelution system , protection againest external light in accordance with EN-54-7,FAP‑520 chamber integrity monitoring , optical fault display, self monitoring of sensor, programmable of timed automatic sensitivity selection with junction box and other accessories as required .shall be EN54/VDs/UL Certification.

1

17885

17885

... More
Addressable Manual Break glass Unit ( Double Action) with flexible network structures & necessary fixing arragements with keys complete as requirwd shall be EN54/VDs/UL ertification.

6

24258

4043

... More
Stand alone loop powered detector base sounder with 32 different tone various selection options & adjustable sound pressure by 5 levels the sound pressure 92.1 db(A) with flasher having synchorized flash rate of 1Hz and light intensity 2cd should be programmed from the panel shall be EN54/VDs/UL Certification.

6

58212

9702

... More
Response indicator with matching screw complete with GI junction box cable lugs at cable and ferulling

-

-

-

... More
FIRE EXIT Signage with LED and battery back up and charger with hanging arrangement complete as required

6

33264

5544

... More
Supplying, laying, testing and commissioning of 2x 1.5 sq mm of Low Smoke Zero Halogen Silicon Insulated Fire Survival Cable with Drain Wire Armouring, solid copper conducter cable approved by LPCB as per BSEN 50200:2015 PH 120 (Fire, Mech Shock & Water 120 Minutes @ 830 deg Celcius, Fire & Mech Shock every 5 Min for 2 Hours- Both test conducted on same sample) and BS-6387 CWZ The cable shall sustain 950 deg. C. For 3 hours approved along with accessories/ termination glands and all necessary materials to complete. The cable shall be BS EN 60332-1-2:2004 for Bunched Flame Retardancy (installed as a single or bunched cable self extinguishes leaving the upper cable sheath unaffected showing the cable does not propagate fire). Cable shall be guaranteed for 10 years from the date of manufacture marked on the cable. (Make: NoBurn, Tyco, Prysmium, Lapp)

5600

744800

133

... More
PUBLIC ADDRESS SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of the following components as required (Make-Bosch, Heinrich, Aties)

-

-

-

... More
Supply,installation ,testing & Commissioning of Voice Alarm Controller having,features like announcement to 6 zones expandable up to 60 zones , built in 240W,Power,255 ,volume control for each zone, Digital pre-recorded messages can be merged.messages can be stored in the internal 16MB flash ROM, individual BGM ,priority levels including emergency, music to selected zones can be played, uptoAmplifier, input port of emergency microphone on the front panel, 16,LBB1990 complete as required. Shop Drawings shall be approved by architect. (Make-Bosch, Heinrich, Aties)

1

138080

138080

... More
Supply,installation ,testing & Commissioning of Plena voice Alarm Call Station having gooseneck condenser Microphone with 6 zone Selection Keys and an All-Call-Key, PTT Switch, selectable gain, speech filter and limiter for improved,intelligibility, LED indication for zone selection complete as required LBD 1956 or equivalent (Make-Bosch, Heinrich, Aties)

1

23776

23776

... More
Supply,installation ,testing & Commissioning of Plena Power Amplifier capable of delivering 480W RMS power output, built-in fan for temperature control,built in line matching transformer distortion typically 0.03% @ 1 KHz, Hum and Noise 90 dB below rated output or equivalet. (Make-Bosch, Heinrich, Aties)

1

35459

35459

... More
Supply,installation ,testing & Commissioning of Plena Power Amplifier capable of delivering 120W RMS power output, built-in fan for temperature control,built in line matching transformer distortion typically 0.03% @ 1 KHz, Hum and Noise 90 dB below rated output or equivalet

1

19196

19196

... More
Supply,installation ,testing & Commissioning of PLN-DVDT Plena BGM Source or 3-CD Changer with AM -FM- Blue ray DVD or equivalent

1

46951

46951

... More
Supply,installation ,testing & Commissioning of Custom built, powder coating , MS sheet , lockable Rack for above equipments

1

27085

27085

... More
Supply,installation ,testing & Commissioning of 6W RMS False Ceiling /wall Mount Speakers with inbuilt 100V Line Matching Transformer, with mounting clamps complete as requierd. (Make-Bosch, Heinrich, Aties)

35

39830

1138

... More
Supply and drawing twin twisted 32/0.2mm PVC insulated copper conductor speaker wire in existing conduit including earth wire (if required) complete as required (for speakers). This includes wiring for the amplifier as well.

875

32375

37

... More
Supply,installation ,testing & Commissioning of Volume control complete as required. (Make-Bosch, Heinrich, Aties)

1

2166

2166

... More
Add labour cess @ 1% on all above items

12013071

120130

0.01



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.