Uttar Pradesh State Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh State Industrial Development Authority - UPSIDA Tender
Electrical and Electronics
Eprocure
Opening Date15 Jul 2019
Closing Date30 Jul 2019
Tender Amount₹ 4,44,62,204
Costs
EMD
₹ 8,89,300Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_SIDC_363454_1Bid Award Id
ViewTender No
ED_1_22_31072019Tender Authority
Uttar Pradesh State Industrial Development Authority ViewPurchaser Address
-Website
http://http://www.onlineupsidc.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply & erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board having arrangement of 630 Amp.TPN-1 No. & Outgoing 315 Amp. TPN-1 No., 200Amp TPN-1 No, 63 Amp TPN-1 & 32 TPN-1No. of Cat-A Cubical type complete as per PWD Sch. No. 805 (b)
20
-
-
Supply, Installation, testing & commissioning of 11 KV RMU (ring main unit) outdoor type, 630 Amp., 20 KA/3Sec., Outdoor (IP54), 5ways comprising 1 No. manual operated, load break switch and 3 Nos. 630 Amp. fixed type manual spring charging VCB, Electrolytic grade copper busbars all inside single, gas filled robotically welded stainless steel 304 (non ferrite, non magnetic grade) tank with minimum thickness 3(+/-) 0.5 mm, IP 67 degree of protection internal arc classified 20 KA/1 Sec., onsite repairable with site replicable bushing/coupling mechanism, gas refilling etc. The enclosure shall have pad lockable double door access with anti theft higes, fully covering the front facia and cable boxes to ensure fail-safe anti theft protection having 01 Nos. 11 KV 630 Amp. incoming load break switch, short time current 20 kA/3 sec., making capacity -50 kAP., Auxiliary contacts-1 No.+INC, 3 Nos. outgoing VCB with 11 KV 630 Amp. fixed type VCB, Short time breaking current/withstand -20kA/3 sec. , Making capacity-50 kAP Auxiliary contacts - 1 No.+INC.
4
-
-
S/L M.S. steel pipe (by trenchless method) made out of steel plate as per IS 2062 grade Fe-400 6mm thick as per IS:3589. The pipe will be laid at a depth of 2m to 3m as per direction of E/I 200 mm dia (A.O.R.)
100
-
-
S/Laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect as per PWD Sch. No. 716
1480
-
-
Providing and fixing of precast reinforced cement concrete 1:1.5:3(1 cement:1.5 coarse sand: 3 graded stone aggregate 20mm nominal size) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement:3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35x93.5x10 cm size (DSR-121No.16.21.3)
130
-
-
Finishing with epoxy paint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concrete work DSR-12/13.52.2
130
-
-
Lettering with black Japan paint of approved brand and manufacturer DSC-12/12.71
2200
-
-
S/Burying of 600x600x6mm G.I. plate vertically for earthing with its top at least 3 M. below ground level complete with 20 mm dia G.I.pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15 mm dia G.I.pipe up to switch board 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal /Coke and salt at least 150mm thick around etc. as per directions of Engineer-in-charge complete in all respect as per as per drawing as per UPPWD Sch. No. 702
148
-
-
S/F of outdoor/indoor type 11 KV jointing kit heat shrinkable type for 11 KV cable including cost of all material, labour, T&P etc. for proper completion of work. (Raychem, Denson/Birla 3M make) for 3 x 185 sq.mm cable
16
-
-
S/F of outdoor/indoor type 11 KV jointing kit heat shrinkable type for 11 KV cable including cost of all material, labour, T&P etc. for proper completion of work. (Raychem, Denson/Birla 3M make) for 3 x 50 sq.mm cable
20
-
-
S/Fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with three color tape (R,Y,B) and making connection etc. complete as per PWD Sch.504 for 120 sq. mm
60
-
-
S/Fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with three color tape (R,Y,B) and making connection etc. complete as per PWD Sch.504 for 150 sq. mm
198
-
-
S/Fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with three color tape (R,Y,B) and making connection etc. complete as per PWD Sch.504 for 240 sq. mm
20
-
-
S/Fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with three color tape (R,Y,B) and making connection etc. complete as per PWD Sch.504 for 300 sq. mm
60
-
-
S/Fixing of brass nickel plated compression gland for PVC insulated cable as per PWD Sch. No. 503 for 150 sq. mm 3.5 core cable
116
-
-
S/Fixing of brass nickel plated compression gland for PVC insulated cable as per PWD Sch. No. 503 for 300 sq. mm 3.5 core cable
40
-
-
S/Laying of 200 mm dia MS pipe ISI marked 6 mm thick as per IS 2062 grade Fe-400 including welding etc. cost of all T & P men & material for proper completion of work complete in all respect.
100
-
-
Supply & fixing of 400 KVA, 11/0.433 KV 3 Phase ONAN core type copper wound outdoor type transformer with voltage ratio between phase at no load as 11000/433 V arranged for star/delta connection as per vector group Dy-11 with neutral brought out on L.V. side. The work will include all standard fitting and accessories, T&P men & material required for proper completion of work including first filling of transformer oil etc. complete in all respect. The transformer would confirm to approved GTP/Drawing/Technical specification and relevant IS required in DISCOM of UPPCL at the time of execution. The manufacturer of transformer shall be in approved list of DISCOM.
10
-
-
Making plinth for installation of transformer of 1.2x1.2x1.2 M plinth complete with excavation base concrete with ratio of 1:4:8 (padding) first class brick work in ratio 1:3 CC work and plastering as per design.
10
-
-
Supply & fixing of welded wire mesh fencing of 5x3x2.4 meter and 2x2.4 M gate including excavation base concrete brick work back filling etc. complete in all respect.
10
-
-
S/L of standard aluminium conductor XLPE (cross linked polyethylene) insulated PVC bedded glavanised flat steel strip armoured cables confirming to IS 7098 (Part-II) with latest amendments, 11 KV grade at a depth of 900 mm below ground level. The armouring of cable shall be properly connected with earth conductor by clamp etc. .(Gloster /Nicco /Havells/Grandlay/Polycab make) as per PWD Sch. No. 506 & 507 for 185 sq. mm 3 core cable
2760
-
-
S/L of standard aluminium conductor XLPE (cross linked polyethylene) insulated PVC bedded glavanised flat steel strip armoured cables confirming to IS 7098 (Part-II) with latest amendments, 11 KV grade at a depth of 900 mm below ground level. The armouring of cable shall be properly connected with earth conductor by clamp etc. .(Gloster /Nicco /Havells/Grandlay/Polycab make) as per PWD Sch. No. 506 & 507 for 50 sq. mm 3 core cable
900
-
-
Supply & fixing of 11 KV straight through jointing kit heat shrinkable type for 11 KV cable including cost of all material,labour, T&P etc. for proper completion of work (Raychem/Denson/Birla make)
6
-
-
S/laying of DWC HDPE pipe ISI marked along with all accessories like socket bend couples etc. conforming to IS 14930. Part II complete with fitting and cutting jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as per DSR Sch. No. 14.16.3 for 120 mm dia (for 50, 150 & 185 sq.mm cable)
6805
-
-
S/laying of DWC HDPE pipe ISI marked along with all accessories like socket bend couples etc. conforming to IS 14930. Part II complete with fitting and cutting jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as per DSR Sch. No. 14.16.3 for 160 mm dia (for 300 sq.mm cable)
890
-
-
Making plinth for installation of LT distribution panel of size 1x1.5x0.9 M plinth complete with excavation base concrete with ratio of 1:4:8 (padding) first class brick work in ratio 1:3 CC work and plastering as per design.
24
-
-
Constructing brick masonry chamber (inside dimentions 455x610 mm and 45 cm deep for single pipe line) for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover with frame to be not less than 38 Kg. (weight o'cover 23 Kg. and weight of frame 15Kg.) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design.
6
-
-