If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - UPRVUNL Tender

Works
Housekeeping Services
Eprocure
Opening Date30 Jun 2023
Closing Date31 Jul 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Cleaning Of Cable Tray Galleries Mcb Routine Bd Maint Of Lt Ht Cable

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Upkeep of marshalling boxes, panels/cabinets of 400/132/33 KV switchyard .

48

-

-

... More
Cleaning of oil pit (lxbxh)- 7x7x3.2 m

6

-

-

... More
Cleaning of oil pit (lxbxh)- 4.5x4x5 m

6

-

-

... More
Cleaning of oil pit (lxbxh)- 2.5x2x1.75 m

6

-

-

... More
Cleaning of latrine pit

8

-

-

... More
Cleaning of roads in 132/400 KV switchyard area

24

-

-

... More
Cleaning of Cable gallery of MCB of 400/132 KV system including trenches of ATPS & BTPS.

24

-

-

... More
PART-A3: The work in this part shall include upkeep of the following areas/locations of ‘B’ TPS switchyard:

-

-

-

... More
Cleaning of site offices, stores, toilet, compressor room, etc

600

-

-

... More
PART-A4 The work in this part shall include upkeep of the online ABT monitoring system:

-

-

-

... More
Cleaning of online ABT monitoring system of ATPS & BTPS.

600

-

-

... More
PART-A5: The works against this part shall include the following jobs pertaining to ‘B’ TPS switchyard. The quantities mentioned are maximum quantity & the quantity may vary widely. These works shall be done as & when required:

-

-

-

... More
Cleaning of all roads within the BTPS switchyard once a month

24

-

-

... More
Cutting of plants more than six inches in height adjacent to BTPS switchyard

6

-

-

... More
PART-A6: The work in this part shall include Removal and disposal of grass, wild plants, shrubs, etc in 400KV Anpara ‘B’TPS switchyard including ICT-3, 33KV Reactor areas: including ICT-3, 33KV Reactor areas)

-

-

-

... More
Removal & Disposal of grass, wild plants, shrubs, etc as per scope of work for approx. 55,000.00 M2 of ‘B’TPS switchyard including ICT-3, 33KV Reactor areas

600

-

-

... More
Removal & Disposal of grass, wild plants, shrubs, etc as per scope of work for approx. 60,000.00 M2 of 400/132KV ‘A’TPS switchyard.

600

-

-

... More
PART-B: The work shall include grass cutting and its removal & disposal to the suitable location as instructed by engineer in charge within the area of ‘A’ & ‘B’ TPS switchyard

-

-

-

... More
PART-B1:(400/132/33/11KV Anpara ‘A’TPS, Switchyard.)

-

-

-

... More
Cutting & Disposal of grass & wild plants, shrubs in surrounding periphery area of 400/132/33 KV switchyard and corridor of unit 1 to 5 transmission lines as per scope of work for approx. 1,80,000.00 M2

360000

-

-

... More
Removal & disposal of cows or any animals from A&B TPS Switchyard.

6

-

-

... More
PART-B2: (132KV Overhead structure of CWT-1 & 2 from 132KV switchyard to CW transformers)

-

-

-

... More
Cutting & Disposal of grass, wild plants, shrubs, etc as per scope of work for approx. 10000.00 M2

80000

-

-

... More
PART-B3:Trimming of trees under the live conductors of ‘A’ &’B’ TPS Trimming of trees (diameter 50mm, height above 2 meters ) up to a height of 500mmwhich grow under the live conductor starting from Turbine Hall to Switchyard and up to 10 meters on either side of the gantry .Diameter of trees shall be measured at 1000 mm from the ground.

-

-

-

... More
50 to 100 mm dia- 70 nos

280

-

-

... More
100 to 150 mm dia-20 nos

80

-

-

... More
Above 150 mm dia-10 nos

40

-

-

... More
PART-B4: (132 KV cable trench including LANCO area.)

-

-

-

... More
Cutting & Disposal of grass, wild plants, shrubs, etc as per scope of work for approx. 7700.00 M2

61600

-

-

... More
PART-B5: (Maintenance of switchyard lawn area.)

-

-

-

... More
Maintenance of grass lawns including cutting if grass with lawn mower or foot drive thresher including watering and removing weed etc. (Area of Lawn=1929 m2)

24

-

-

... More
PART-C

-

-

-

... More
Preparation & spray of anti weed solution in 400KV 'A'TPS switchyard area. (three times in a year- 3Job)

270000

-

-

... More
Preparation & spray of anti weed solution in 400KV 'B'TPS switchyard area. (three times in a year- 3Job)

330000

-

-

... More
Preparation & spray of anti weed solution in 132KV 'A'TPS switchyard area. (three times in a year- 3Job)

180000

-

-

... More
Preparation & spray of anti weed solution in adjacent area of A and B TPS 400/132KV switchyard area (three times in a year- 3Job)

180000

-

-

... More
PART-D

-

-

-

... More
Cleaning of cable trays and cable risers of Power cables & Control cables of various cable galleries, boiler areas, mill areas (excluding 0 to 15 mtr), TG floor, DFA & ESP areas (Under scope of work of EMD-II, BTPS) of unit #4 & #5of 2X500MW, BTPS, Anpara

24

-

-

... More
PART-E1

-

-

-

... More
Routine maintenance of various cabling works which includes salvaging, laying and end termination, straight through jointing, repairing tracing of L.T. power /control cable of different sizes and No. of cores subjected to maximum size of 25 mm2 Maintenance of existing MS perforated and ladder type trays, junction boxes, conduit and tray covers of ‘B’TPS, Anpara (Except coal handling area).

24

-

-

... More
PART-E2

-

-

-

... More
H.T. power cable armoured XLPE aluminium conductor of following sizes.

-

-

-

... More
1C x 630 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
1C x 1000 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
3C x 150 to 300 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
3C x 400 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
Opening of cable terminal box & disconnection of power cable

-

-

-

... More
Salvaging

1

-

-

... More
Connection of power cable & cleaning of terminal box

-

-

-

... More
Salvaging

1

-

-

... More
L.T. power cable armoured PVC aluminium conductor of following sizes.

-

-

-

... More
1C x 26 to 150 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
1C x 400 to 630 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
1C x 800 to 1000 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
2C x 26 to 70 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
2C x 71 to 185 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
2C x 240 to 400 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
3C x 26 to 70 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
3C x 71 to 120 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
3C x 150 to 240 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
3C x 300 to 400 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
4C x 26 to 95 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
4C x 120 to 240 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
4C x 300 to 400 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
L.T. power cable armoured PVC copper conductor of following sizes.

-

-

-

... More
1C x 26 to 150 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
1C x 400 to 630 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
1C x 800 to 1000 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
2C x 26 to 70 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
2C x 71 to 185 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
2C x 240 to 400 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
3C x 26 to 70 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
3C x 71 to 120 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
3C x 160 to 240 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
3C x 300 to 400 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
4C x 26 to 95 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
4C x 120 to 240 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
4C x 300 to 400 mm2

-

-

-

... More
Salvaging

1

-

-

... More
Laying

1

-

-

... More
End Termination (One End of Cable)

1

-

-

... More
Straight Through Joint

1

-

-

... More
Repairing/ Tapping of Cable

1

-

-

... More
Laying of new L.T. Power / Control cable of different sizes and nos. of cores subjected to maximum size of 25 sq. mm as per site requirement additional except existing laid cables

-

-

-

... More
Laying

1

-

-

... More
PART-E3

-

-

-

... More
Fabrication of cable racks and other steel structure. (Rate/M.T.)

1

-

-

... More
Tray Erection

-

-

-

... More
Erection of G.I. /M.S. perforated & ladder type tray of different sizes. (Rate in R.M.)

1

-

-

... More
Fixing of new tray cover of different sizes. (Rate in R.M.)

1

-

-

... More
Erection of junction boxes off size. (Rate/No.)

1

-

-

... More
Erection of conduit pipe of following size. (Rate in R.M.)

-

-

-

... More
Up to 75-mm. dia.

1

-

-

... More
Above 75 mm. dia.

1

-

-

... More
Erection of conduit pipe under concrete/cement floors. (Rate in R.M. )

-

-

-

... More
Up to 75-mm. dia.

1

-

-

... More
Above 75 mm. dia.

1

-

-

... More
Digging of earth for laying removal of cable having size more than 77 mm. /control & instrumentation cable and refilling same. (Rate in R.M.)

1

-

-

... More
Installation of welding sockets / MCCB. / D.B. etc (Rate/No.)

1

-

-

... More
Cleaning of cable trench of 2X500MW, ‘B’TPS, Anpara. (Rate in R.M.)(Expect coal handling area)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.