Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - UPRVUNL Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date6 Nov 2024
Closing Soon27 Nov 2024
Tender Amount₹ 13,00,000
Costs
EMD
₹ 13,000Document Cost
₹ 1,180Tender Fee
Refer Documents
Summary
Supply Of Material
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RVUNL_971440_1Tender No
113/PD-I/MMC-II/ATP/2024-25Tender Authority
Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited ViewPurchaser Address
-Website
http://https://uprvunl.org/uprvunl
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
High Voltage HRC fuse link M/s Bussmann: #Model- 12ABCNA3.15, 12 Kv, 3.15 Amps with# recommended fuse clip
10
-
-
Rechargeable Battery for METREL Make 5KV Insulation Resistance Tester Model- MI-2077, Capacity- 4500 mAH, Voltage- 1.2V, Type-NiMH, Type-C, Product Code- A1046.#One Set Consist of 6 Batteries.
2
-
-
Powertech make SMPS#220VDC/24VDC 10A#Model Type 300SI#Sr No-PSPL/11-12/3414
2
-
-
Model-8085 Reactive Transducer,3Phase 3 Wire Unbalanced,##Output : 4-12-20 mA DC Dual,##Input: 110V AC; 0-1 A, Frequency: 50 Hz, Aux. supply: 240V AC, Accuracy Class:0.2%, Range: 190.52Var lead-0-##190.52 Var lag Ordering code: 8085/228/172/251/352/17/A2/, Make : SOUTHERN TRANSDUCERS
1
-
-
Model-8075 Active Transducer,3Phase 3 Wire Unbalanced, Output : 4-20 mA DC Dual,##Input: 110V AC; 0-1 A AC, Frequency: 50 Hz, Aux. supply: 240V AC, Accuracy Class:0.2%, Range: 0-600 MW, CT ratio:20000/5A, Rated current at 0.85pf, 21KV, 500MW:16166A, PT ra : (21KV/#3) / (110V/#3) Ordering code: 8075/221/172/251/352/17/A2/0, Make : SOUTHERN TRANSDUCERS
3
-
-
Model-8091 Power Factor Transducer,3 phases, Output : 4-12-20 mA DC,##Input: 110V AC; 0-1 A AC, Frequency: 50 Hz, Aux. supply: 240V AC, Accuracy Class:0.02 pf, Range: 0.5 lead-1-0.5##lag, Ordering code: 8091/2/220/172/251/352/17/A1/0, Make : SOUTHERN TRANSDUCERS
2
-
-
Model-8066 AC Current Transducer, Output : 4-20 mA DC Single,##Input: 0-1 A AC(Transducer to be calibrated to 12mA for 1A AC input), Frequency: 50 Hz, Aux. supply: 240V AC, Accuracy Class:0.5, Ordering code:##8066/220/251/352/17/A1/0, Make : SOUTHERN TRANSDUCERS
1
-
-
Model-8061 AC Voltage Transducer ,Output : 4-20 mA DC Single,##Input: 0-110V AC(Transducer to be calibrated to 14.67mA for 110 V AC input), Input Range: 0-137.5V AC, Frequency: 50 Hz, Aux. supply: 240V AC, Accuracy Class:0.5%,##Ordering code: 8061/220/172/ 7/A1/0, Make : SOUTHERN TRANSDUCERS
2
-
-
Model-8020 DC Voltage Transducer, Output : 4-20 mA DC Dual Isolated,##Input: 0-300V DC, Aux. supply: 240V AC, Accuracy Class:0.5%,##Di-electric Test Vol. 4 KV rms for 1 min, Ordering code:##8020/221/305/09/0/1/2, Make : SOUTHERN TRANSDUCERS
2
-
-
Model-8020 DC Voltage Transducer, Output : 4-20 mA DC Dual Isolated,##Input: 0-60mV DC, Aux. supply: 240V AC, Accuracy Class:0.5%,##Di-electric Test Vol. 4 KV rms for 1 min, Ordering code:##8020/221/009/09/0/2, Make : SOUTHERN TRANSDUCERS
2
-
-
Model-8020 DC Voltage Transducer, Output : 4-20 mA DC Dual Isolated,##Input: 0-40V DC, Aux. supply: 240V AC, Accuracy Class:0.5%,##Di-electric Test Vol. 4 KV rms for 1 min, Ordering code:##8020/221/009/17/0/1/2, Make : SOUTHERN TRANSDUCERS
2
-
-
Model-8020 DC Voltage Transducer,##Output : Isolated 4-20 mA DC,Input: -15V-0-+15V DC,##Aux. supply: 240V AC, Accuracy Class:0.5%, Di-electric##Test Vol. 2 KV rms for 1 min, Ordering code:##8020/221/009/17/0/0 SA0653942230, Make : SOUTHERN TRANSDUCERS
2
-
-
Model-8020 DC Voltage Transducer, ##Output : 4-20 mA DC Single,Input: 0-10V DC, Aux. supply: 240V AC, AccuracyClass:0.2%,##Di-electric Test Vol. 1.5 KV rms for 1 min##Ordering code: 8020/220/153/17/0/0, Make : SOUTHERN TRANSDUCERS
2
-
-
FREQ. TRANSDUCER #Make : SOUTHERN TRANSDUCERS HSN Code: 90303340#Type No. : 8071 # FREQUENCY #TRANSDUCER#Output : 4-20mA DC Dual Isolated (R max: 500#)#PT Input Voltage : 110V AC #Frequency Range : 45-55Hz.#Aux#Supply : 240V AC; 50Hz#Accuracy : ±0.2% of Span# damping #Insulation Level : 3 KV AC; 50Hz for 1 minute(Between O/P#s 2#KV AC)#Ordering Code : 8071/221/172/321/17/A2/0#Dimension : 75 X 70 X 113 (L X W X H)
1
-
-
Auxiliary Relay RE 301 4 C/O S/R contacts with LED Indication Coil Voltage- 24 V DC, Jyoti make
12
-
-
AUX RELAY RE 300, 4 C/O S/R contacts with LED Indication ,#Coil Voltage- 220 V DC, Jyoti make#
8
-
-
UT Transformer Cooling Fan, Model- 45063, Sweep-450mm, Power-132W, Three Phase Motor, FLC-0.3A, RPM-900, Air Flow- 4500
m3/Hr, Type of Running-Form-A, IP55, Make- Marathon Electric
8
-
-
Power Fuse 315A, Size 2 Type- VSK315, Make- Bussmann
3
-
-
Power Fuse 250A, Size 1 Type- VSF250, Make- Bussmann
9
-
-
Power Fuse 80A, Size 00 Type- VSB80, Make- Bussmann
9
-
-
Fuse NS Type 2A, Make- Bussmann
10
-
-
Fuse NS Type 4A, Make- Bussmann
10
-
-
Fuse NS Type 6 A, Make- Bussmann
10
-
-
Fuse NS Type 10 A, Make- Bussmann
10
-
-
Fuse NS Type 16 A, Make- Bussmann
10
-
-
Fuse NS Type 20 A, Make- Bussmann
10
-
-
Fuse NS Type 32A, Make- Bussmann
10
-
-
Fuse NS Type 50A, Make- Bussmann
10
-
-
Siemens make Fuse#3NW TIA6 gG 6Amps#440VAC 220VDC
10
-
-
Siemens make Fuse#3NW TIA10 gG 10Amps#440VAC 220VDC
8
-
-
Siemens make Fuse#3NW TIA25 gG 25Amps 440VAC 220VDC
8
-
-
Siemens make Circuit Breaker Miniature with Aux. Contact Block# Type 5SX52 C25 220/440V Icu 10kA acc.to IS:13947-2#Aux Contact Block: 5SX9100 HS 6A/230VAC, 1A/220VDC 1NO+1NC##
2
-
-
Siemens make Air Break (Aux) Contactor Relay#(i)01 No. Type 3TH30 40-0B Aux Contact 4 NO, Ie/AC15, System Voltage 500VAC/600VDC, COIL VOLTAGE 220VDC +10%, -15%,IEC 947, IS: 13947, with (ii) 4Nos. Of NC Add on Contact Block Type-Siemens 3TX4001-2A IS:13947 IEC 60947 with#(iii) 01 No. Surge Suprressor (Varistor) # Type- Siemens 3TX7 402-3JY1#Us 150-250 VDC
3
-
-
Siemens make Air Break (Aux) Contactor Relay#(i) 01 No. Type 3TH30 40-0A Aux Contact 4 NO, Ie/AC15, System Voltage 240VAC,10A, COIL VOLTAGE 240VAC +10%, -15%,IEC 947, IS: 13947, with (ii) 4Nos. Of NC Add on Contact Block Type-Siemens 3TX4001-2A IS:13947, C 60947#
3
-
-
ABB make (i) 2 Pole MCB with Auxiliary Contact Block.# ABB S282 UC K3A, 440VAC/440VDC,#Order Code-GH S282 0164 R0317#(ii) AUX CONTACT BLOCK-#H-11(1NO+1NC) FOR ABB S282 UC K3A, 440VAC / 440VDC MCB#
4
-
-
ABB make (i) 3Pole Motor Protection CB having O/L, Short Circuit & Single Phase Protection , Rated Thermal Current 25A, Rated Operating Voltage 690 VAC , RAted Short Cuircuit Breaking Capacity 75kA at 400V. MS325-12.5, 690VAc, AC3, Setting Range
9-12.5A ( i) AUX CONTACT BLOCK- HK-11(1NO+1NC) FOR MS325-4Order Code-1SAM 101 901 R0001
2
-
-
ABB make (i) 3Pole Motor Protection CB having O/L, Short Circuit & Single Phase Protection , Rated Thermal Current 25A, Rated
Operating Voltage 690 VAC MS325-4 690VAc, Setting Range 2.5-4A Order Code-1SAM 150 000 R1008 (ii) AUX CONTACT
BLOCK- HK-11(1NO+1N ) FOR MS325-4 Order Code-1SAM 101 901 R0001
1
-
-
ABB make (i) 3Pole Motor Protection CB having O/L, Short Circuit & Single Phase Protection , Rated Thermal Current 25A, Rated
Operating Voltage 690 VAC MS325-1 690VAc, Setting Range 0.63-1A Order Code-1SAM 150 000 R1005 (ii) AUX CONTACT
BLOCK- HK-11(1NO+1 C) FOR MS325-1 Order Code-1SAM 101 901 R0001
2
-
-
FULLY AUTOMATIC STAR DELTA STARTER FOR 20 HP MOTOR WITH GRP PANAL BOX SIZE 750X500X250 MM WITH SFU, PT (440/110 Volt), THERMAL O/L, POWER CONTACTOR, STAR-DELTA TIMER, ON OFF PUSH BUTTON, AND INDICATION LAMP OF ON, OFF, O/L, WATER LEVEL HIGH AND LOW ON PAN L DOOR, Make: M/s C&S / M/s ABB / M/s HENSAL / M/s PUSTRON
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%