Uttar Pradesh Rajkiya Nirman Nigam Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Rajkiya Nirman Nigam - UPRNN Tender

Works
Electrical Works
Eprocure
Opening Date21 Nov 2024
Closing Soon28 Nov 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Diesel Engine 4 stroke radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 400C, 50% RH & at 1000 metre MSL and confirming to BS 5514, bs 649, is 10000, capable of taking 10% overloading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories.

-

-

-

... More
Engine Mounted Instrument Panel fitted with and having digital display for following:

-

-

-

... More
Start- stop switch with key.

-

-

-

... More
Water Temperature indication

-

-

-

... More
Lubrication Oil pressure indication

-

-

-

... More
Battery charging indication

-

-

-

... More
RPM indication

-

-

-

... More
Over Speed trip Indication

-

-

-

... More
Low lubrication oil trip indication

-

-

-

... More
Engine Hours Indication

-

-

-

... More
Alternator:

-

-

-

... More
Synchronous alternator rated at 1250 KVA, 415 Volts at 1500 RPM, 3 phase 50 Hz, AC Supply with 0.8 lagging power factor at 400C, 50% RH & at 1000 metre MSL. The alternator shall be having SPDB enclosure, brushless, continuous duty, self-excited and self-regulated through AVR confirming to IS:4722/ BS 2613 suitable for tropical conditions and with class- F insulation.

-

-

-

... More
Base Frame & Foundation

-

-

-

... More
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.

-

-

-

... More
Fuel Tank:

-

-

-

... More
Daily service fuel tank of 990 litres capacity, fabricated out of 3mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C pipes of suitable dia. Complete with valves level indication & accessories as required as per specifications

-

-

-

... More
Exhaust System :

-

-

-

... More
Dry exhaust mainfold with hospital grade exhaust silencer and catalytic convertor.

-

-

-

... More
Starting System:

-

-

-

... More
24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with 2 Nos. of batteries (25 plates, 160 AH lead Acid type) as required as per specifications.

-

-

-

... More
Diesel Generating Set 1250 K.V.A. described as above.

2

-

-

... More
Providing, installation testing & commissioning of 'Silent Type' Diesel Generating Set along with having prime power rating 500 KVA, 415 Volts at 1500RPM, 0.8 lagging Factor at 415 V suitable for 50 Hz, 3 phase system and for 0.85 load factor and consisting of the following:-

-

-

-

... More
Diesel Engine

-

-

-

... More
Diesel Engine 4 stroke radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 400C, 50% RH & at 1000 metre MSL and confirming to BS 5514, bs 649, is 10000, capable of taking 10% overloading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories.

-

-

-

... More
Engine Mounted Instrument Panel fitted with and having digital display for following:

-

-

-

... More
Start- stop switch with key.

-

-

-

... More
Water Temperature indication

-

-

-

... More
Lubrication Oil pressure indication

-

-

-

... More
Battery charging indication

-

-

-

... More
RPM indication

-

-

-

... More
Over Speed trip Indication

-

-

-

... More
Low lubrication oil trip indication

-

-

-

... More
Engine Hours Indication

-

-

-

... More
Alternator:

-

-

-

... More
Synchronous alternator rated at 500 KVA, 415 Volts at 1500 RPM, 3 phase 50 Hz, AC Supply with 0.8 lagging power factor at 400C, 50% RH & at 1000 metre MSL. The alternator shall be having SPDB enclosure, brushless, continuous duty, self-excited and self-regulated through AVR confirming to IS:4722/ BS 2613 suitable for tropical conditions and with class- F insulation.

-

-

-

... More
Base Frame & Foundation

-

-

-

... More
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.

-

-

-

... More
Fuel Tank:

-

-

-

... More
Daily service fuel tank of 990 litres capacity, fabricated out of 3mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C pipes of suitable dia. Complete with valves level indication & accessories as required as per specifications

-

-

-

... More
Exhaust System :

-

-

-

... More
Dry exhaust mainfold with hospital grade exhaust silencer and catalytic convertor.

-

-

-

... More
Starting System:

-

-

-

... More
24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with 2 Nos. of batteries (25 plates, 160 AH lead Acid type) as required as per specifications.

-

-

-

... More
Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per specifications.

-

-

-

... More
Diesel Generating Set 500 K.V.A. described as above.

1

-

-

... More
D.G. AUX PANEL AND ISOLATORS-- D.G. AUXILIARY PANEL- BLOCK-1

-

-

-

... More
Supply, Installation, Testing and Commissioning of M.V. cubicle type totally enclosed free standing type, dust, damp and vermin proof D.G. Auxillary Panel made out of 14 SWG CRCA sheet complete with aluminium busbars, ammeter, ammeter selector switch, voltmeter, voltmeter selector switch, indicating lamps, CT’s, interconnections with suitable capacity aluminium leads/solid aluminium strips/ rods, interlocking, wiring powder coated and having following incoming and outgoing moulded case circuit breakers with rotary operating handle, starters, timers, etc. complete as per drawing and specification.

-

-

-

... More
(NOTE:- All MCCB SHALL BE MOTOR DUTY)

-

-

-

... More
INCOMING

-

-

-

... More
2 Nos. 160Amp FP Moulded Case Circuit Breaker.

-

-

-

... More
1 Nos Fixed type Automatic transfer switch 160 Amp rating in open frame with  live to live transfer time  200ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS.

-

-

-

... More
1 No. Digital AVF Meter with inbuilt selector switch.

-

-

-

... More
1 Set of phase indicating lamps with Single Pole MCB.

-

-

-

... More
1 Set of ON / OFF indicating lamps with Single Pole MCB.

-

-

-

... More
BUSBARS

-

-

-

... More
1 Set of 200Amp TPN busbar of aluminium alloy.

-

-

-

... More
OUTGOING

-

-

-

... More
3 Nos. 63Amp TP moulded case circuit breaker with Starter/Delta Starter suitable for monoblock pump (15.0 HP).

-

-

-

... More
2 Nos. 40Amp TP moulded case circuit breaker with DOL Starter suitable for cooling pump (7.5 HP).

-

-

-

... More
3 Nos. 40Amp TP moulded case circuit breaker with DOL Starter suitable for cooling tower fan (7.5 HP).

-

-

-

... More
2 Nos. 20Amp TP moulded case circuit breaker with DOL starter suitable for Cooling Tower Fan (3.0 HP).

-

-

-

... More
4 Nos. 20Amp TP moulded case circuit breaker with DOL starter suitable for HSD motor (3 H.P).

-

-

-

... More
3 Nos. 20Amp TP moulded case circuit breaker with DOL starter suitable for LTA Pump (3 H.P.

-

-

-

... More
2 Nos. 20 to 40 Amp. TP moulded case circuit breaker with DOL Starter. (Spare)

-

-

-

... More
Each DOL starter shall essentially have following.

-

-

-

... More
1 No. TP Power contactor.

-

-

-

... More
1 No. Overload relay

-

-

-

... More
1 No. Single phase preventor (Voltage sensing based)

-

-

-

... More
1 No. PLC./Manual selector switch.

-

-

-

... More
2 No. start/stop push buttons

-

-

-

... More
2 No. ON/OFF indicating lights.

-

-

-

... More
1 No. Trip indicating lights.

-

-

-

... More
1 No. Direct type ammeter.

-

-

-

... More
1 No.Auxillary contacts (4NO+ 4 NC).

-

-

-

... More
1 Set control fuses.

-

-

-

... More
Each Star / Delta Starter shall essentially have following.

-

-

-

... More
3 No. TP Power contactor.

-

-

-

... More
Timer for fully automatic operation.

-

-

-

... More
1 No. Overload relay

-

-

-

... More
1 No. Single phase preventor (Voltage sensing based)

-

-

-

... More
1 No. PLC./Manual selector switch.

-

-

-

... More
2 No. start/stop push buttons.

-

-

-

... More
2 No. ON/OFF indicating lights.

-

-

-

... More
1 No. Trip indicating lights.

-

-

-

... More
1 No. Direct type ammeter.

-

-

-

... More
1 No.Auxillary contacts (4NO+ 4 NC).

-

-

-

... More
1 Set control fuses.

-

-

-

... More
D.G. Aux Panel described as above

1

-

-

... More
Isolator Switches With Metal Enclosure ( IP-55)

-

-

-

... More
40 A 3 pole isolator switch for cooling Tower with sheet metal enclosure, rain protection etc. as required to suit the site condition.

2

-

-

... More
20 A 3 pole isolator switch for cooling Tower with sheet metal enclosure, rain protection etc. as required to suit the site condition.

1

-

-

... More
Supplying, installatin, testing & commissioning of following dia M.S. Pipe heavy duty class C with all accessories such as bends flanges as required at site for DG Exhaust as per relevant IS:3589 including LRB rock wool insulation having 100 kg per m3 density 75 mm thick for 450 mm , chicken wire mesh and cladding with 24 gauge aluminium sheet, for exhaust of smoke of D.G. Sets including fixing the M.S. cladded pipes on the existing structure including fixing of silencers, flexible bellows on the wall/ ceiling including cutting, welding primer coating and painting cost of supports etc. complete as required.

-

-

-

... More
350 mm dia MS pipe. (5.2 mm thick)

240

-

-

... More
300 mm dia MS pipe. (5.2 mm thick)

120

-

-

... More
250 mm dia MS pipe. (5.2 mm thick)

60

-

-

... More
Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. Providing, designing, welding, fixing & painting (two coats of primer & two coats of synthetic enamel paint of approved shade) with suitable sizes ISMC (100x75mm) angle iron / MS channels supports along with a wall / water piping support and free standing structure on roof of terrace along with lightening arrester / aviation light for DG fume pipes as per CPCB-II approved norms & complete as required. (support details shall be got approved before execution). DSR 2018 civil 10.25.1

35000

-

-

... More
D.G. COOLING SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of approved site errected FRP Induced draft counter flow twin cell direct driven tower with internal supporting structure of heat rejection capacity as given below based on the parameters given below and complete with all the items as given below and as specififed under technical specifications of the tender and offer shall have compliance statement with respect to the tender specification. The tower shall be with louvers, fill & drift eliminators and design of these item to ensure minimum resistance to flow of air.

-

-

-

... More
Cold water basin & sump of deep fibreglass reinforced with down discharge and screened suction assembly with drain, overflow, automatic make-up water, equalizing & quick fill arrangements and connection provision etc; TEFC Motor working on 415 volts ±10%, 3 phases, 50 Hz ± 5%, AC supply and EEF1 grade IP-55 rating capable of working under moist steam with weatherproof construction and GSS canopy etc; Statically and dynamically balanced acoustically treated Propeller Fan with fan guard and lightweight rotor fitted with multiple aerofoil blades with RPM less than 750 etc; PVC cross fluted design fills of corrosion proof and rigid in construction and arranged in square / rectangular form, elevated from the floor of the cold water basin, arranged in negligible resistance manner to airflow and to eliminate backwater spots and prevent fouling trough scales. PVC drift eliminators etc; Hot water distribution header with branched arms system etc;

-

-

-

... More
The tower shall be with stainless steel ladder and accessories, all pipe connections hot dip galvanized and double flanged, colour finish of tower as per architect / consultant / client decision. The maximum allowable sound power at a distance of 3 M from the cooling Tower shall be less than 80 dB. The cooling Tower Model shall be to suit site condition.

-

-

-

... More
For 1250 KVA D.G. Set

-

-

-

... More
Heat Rejection Capacity - 613000 Kcal / Hr.

-

-

-

... More
Tower Base / Fill Area Min - 10.00 SMT

-

-

-

... More
Nos. of Cell - 01

-

-

-

... More
Nos. of Fan / Cell - 01

-

-

-

... More
Water Flow - 1300 LPM

-

-

-

... More
Designed Wet Bulb Temperature - 28.9 °C

-

-

-

... More
Water Inlet / Outlet Temperature - 42.00 °C / 32.0 °C

-

-

-

... More
Cooling Tower Basin Height - 300.0 MM Minm.

-

-

-

... More
Supply, Receiving, Unloading, Shifting to foundation, Installation, Testing & Commissioning.

2

-

-

... More
For 500 KVA D.G. Set

-

-

-

... More
Heat Rejection Capacity - 280000 Kcal / Hr.

-

-

-

... More
Tower Base / Fill Area Min - 4.0 SMT

-

-

-

... More
Nos. of Cell - 01

-

-

-

... More
Nos. of Fan / Cell - 01

-

-

-

... More
Water Flow - 535 LPM

-

-

-

... More
Designed Wet Bulb Temperature - 28.9 °C

-

-

-

... More
Water Inlet / Outlet Temperature - 42.00 °C / 32.0 °C

-

-

-

... More
Cooling Tower Basin Height - 300.0 MM Minm.

-

-

-

... More
Supply, Receiving, Unloading, Shifting to foundation, Installation, Testing & Commissioning.

1

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (DSR Wet Riser 2019)

-

-

-

... More
200 mm dia (6.3 mm Thick) (DSR Wet Riser 2019 7.9)

450

-

-

... More
150 mm dia (DSR Wet Riser 2019 7.8)

120

-

-

... More
100 mm dia (DSR Wet Riser 2019 7.7)

40

-

-

... More
80 mm dia (DSR Wet Riser 2019 7.6)

18

-

-

... More
50 mm dia (DSR Wet Riser 2019 7.4)

40

-

-

... More
40 mm dia (DSR Wet Riser 2019 7.3)

20

-

-

... More
32 mm dia (DSR Wet Riser 2019 7.2)

12

-

-

... More
VALVES & STRAINERS

-

-

-

... More
Supply, fixing commissioning and testing of following valves, strainers, in the D.G. cooling system piping complete with companion flanges, nut bolts, gaskets, supports and painted etc. as per specifications.

-

-

-

... More
Butterfly valves:

-

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 ,flanges as per IS 6392 Table "E". Valves of sizes 32 mm and above diameter of cast iron close end body, cast iron epoxy coated disc, Nitrile Seat and SS 410 Stem with tefflon bush. Valves up to 150 mm NB with detachable hand lever operation whereas valves above 150 mm NB with warm gear operation. (DSR Wet Riser 2019)

-

-

-

... More
200 mm dia (DSR Wet Riser 2019 11.7)

3

-

-

... More
150 mm dia (DSR Wet Riser 2019 11.6)

14

-

-

... More
100 mm dia (DSR Wet Riser 2019 11.5)

8

-

-

... More
80 mm dia (DSR Wet Riser 2019 11.4)

2

-

-

... More
50 mm dia (DSR Wet Riser 2019 11.2)

3

-

-

... More
40 mm dia/32 mm dia (DSR Wet Riser 2019 11.1)

12

-

-

... More
Non Return Valves:

-

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc with Dual plate check valves shall conform to PN 1.6 rating with design confirming to API 594 and tested as per ANSI SERIES. Valves shall have cast iron body, and SS 410 plates, SS 410 Shaft & Nitrile Seat. (DSR Wet Riser 2019)

-

-

-

... More
150 mm dia (DSR Wet Riser 2019 14.7)

5

-

-

... More
100 mm dia (DSR Wet Riser 2019 14.5)

3

-

-

... More
Y-strainers:

-

-

-

... More
Y-Strainer confirming to SSPL 107 shall have cast iron body with tested at 16 Kg/sq. cm pressure, screen shall be made out of 3 mm perforated stainless steel sheet and to be easily removable when required to be cleaned, permanent magnet in the strainer body to arrest MS particles, filter element nonmagnetic type of 20 gauge SS sheet with 3 mm perforation. (DSR Wet Riser 2019)

-

-

-

... More
150 mm dia (DSR Wet Riser 2019 15.3)

3

-

-

... More
100 mm dia (DSR Wet Riser 2019 15.2)

2

-

-

... More
Pot Strainers:

-

-

-

... More
Pot Strainer confirming to SSPL 106 shall have cast iron body and factory tested at works at 16 Kg/sq. cm pressure with flanged end as per Table-E, BS 10 . The screen / filter shall be made out of 3 mm perforated stainless steel sheet of SS-304 grade capable for heavy duty operation. A cone with sufficiently large drain pipe with butterfly valve at the bottom chamber to flush-out foreign particles shall be part of the pot strainer. A powerful magnet shall be provided in the body to arrest MS particles.

-

-

-

... More
200 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
Supply, installation, testing and commissioning of End Suction / Monoblock cooling water centrifugal pump sets (Monoblock pump up to 7.5 HP and end suction above 7.5 HP) with bronze impeller for condenser water recirculation complete with TEFC Sq. Cage induction motor with class "F" insulation, base plate, coupling guard, vibration isolators, SS Shaft, factory fitted mechanical seal, flexible pipe connector at inlet and outlet etc. conforming to technical specification & as per following parameters. The capacity of motor shall be at least 15% in excess of BHP requirement of pump.

-

-

-

... More
1300 LPM, 30 M Head, 15 HP minimum.

3

-

-

... More
535 LPM, 30 M Head., 7.5 HP minimum.

2

-

-

... More
Supply, installation, testing and commissioning of auto air vent valve of following sizes:-

-

-

-

... More
Auto Air vent 1 inches

10

-

-

... More
Bal valve 1 inches

10

-

-

... More
Supply, installation, testing and commissioning of alcohal fitted 'V' form thermometer of approved make conforming to tender specifications and of direct reading V form type with alcohol filled of range 0.0 to 60.0 Deg. C. The V form thermometer shall be made of aluminium die casting with golden colour anodizing. The thermometer shall have a V groove in the body to protect the refill from the damages during the installation. The refill shall be filled with blue colour mercury. The thermometer shall be complete with brass well & the calibration of temperature shall be in Celsius & Fahrenheit.

14

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as per approved make of dia 150 mm with maximum dial pressure of 10 bar conforming to tender specifications and made of stainless steel grade SS304. The dial plate shall be powder coated with white colour base & the calibration shall be done in black colour. All the pressure gauges shall be complete with ball valves & SS Siphon and confirming to IS:3624. (DSR Elect 2018 16.8)

14

-

-

... More
Supply and Laying of copper conductor PVC Insulated armoured served sheathed cable 1100 volt grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with brunt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamp etc of suitable size or as directed by the engineer incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamp etc.

-

-

-

... More
4 core, 6 sq.mm

1300

-

-

... More
2 core, 6 sq.mm.

300

-

-

... More
4 core, 2.5 sq.mm

300

-

-

... More
12 core, 2.5 sq.mm

600

-

-

... More
2 core, 2.5 sq.mm

300

-

-

... More
Supply and making end termination with brass compression glands following sizes of FRLS / PVC insulated and PVC sheathed/ XLPE aluminium/ copper conductor cable of 1.1kv grade of the following sizes as required. (DSR-2018-9.1)

-

-

-

... More
4 core, 6 sq.mm./4 core 10 Sqmm (DSR-2018-9.1.32)

32

-

-

... More
2 core, 6 sq.mm. (DSR-2018-9.1.1)

6

-

-

... More
4 core, 2.5 sq.mm/ 2core 6 Sqmm (DSR-2018-9.1.1)

6

-

-

... More
12 core, 2.5 sq.mm/ 4 core 10 sqmm (DSR-2018-9.1.32)

20

-

-

... More
2 core, 2.5 sq.mm/ 2core 6 Sqmm (DSR-2018-9.1.1)

6

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (DSR-2018-4.6)

-

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness. (DSR-2018-4.6.2)

150

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness. (DSR-2018-4.6.4)

220

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness. (DSR-2018-4.6.6)

450

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (DSR-2018-4.7)

-

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness. (DSR-2018-4.7.2)

6

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness. (DSR-2018-4.7.4)

12

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness. (DSR-2018-4.7.6)

8

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (DSR-2018-4.8)

-

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness. (DSR-2018-4.8.2)

2

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness. (DSR-2018-4.8.4)

4

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness. (DSR-2018-4.8.6)

7

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. (DSR-2018-4.9)

-

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness. (DSR-2018-4.9.2)

8

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness. (DSR-2018-4.9.4)

5

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness. (DSR-2018-4.9.6)

4

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (DSR-2018-4.10)

-

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness. (DSR-2018-4.10.2)

3

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness. (DSR-2018-4.10.4)

6

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness. (DSR-2018-4.10.6)

8

-

-

... More
Supply and Laying of aluminium conductor PVC Insulated armoured served sheathed cable 1100 volt grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with brunt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamp etc of suitable size or as directed by the engineer incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamp etc. (UPPWD 2018 P.S. NO 501

-

-

-

... More
3.5 core, 300 sq.mm. P.S. NO 501(s)

7200

-

-

... More
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. (DSR 2018 9.1)

-

-

-

... More
3½ X 300 sq. mm (70mm) (DSR 2018 9.1.30)

120

-

-

... More
Supply and burring of Safe Earthing Electrode T-39 Cu Copper Coated, Length up to 3000mm, outer pipe 76.3mm x 3.2 inner pipe 42.4mm x 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 Copper Strip will be extra). Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. UPPWD SOR-2018, 727(D)

6

-

-

... More
Supply and burring of Safe Earthing Electrode T-39 (Hot-Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia 38mm terminal Dia 12 mm ,outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 X 3 GI. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. UPPWD SOR-2018, 725(D)

10

-

-

... More
Providing, Fixing, Testing & Commissioning of following copper strip wire on surface of wall/ trench including insulator with heat shrinkable sleeves etc. as required. (DSR 2018)

-

-

-

... More
50mm x 5mm (DSR 2018 5.20)

720

-

-

... More
25mm x 5mm (DSR 2018 5.14)

10

-

-

... More
Providing, Fixing, Testing & Commissioning of following G.I. Strip/ G.I. wire on surface of wall/ trench etc. as required. (DSR 2018)

-

-

-

... More
50mm x 5mm (DSR 2018 2 x5.15)

850

-

-

... More
25mm x 5mm (DSR 2018 5.15)

1080

-

-

... More
6 SWG G.I. Wire (DSR 2018 5.18)

600

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. (DSR 2018 14.14)

-

-

-

... More
150mm dia R.C.C. pipe (DSR 2018 14.14.2)

230

-

-

... More
250mm dia R.C.C. pipe (DSR 2018 14.14.3)

200

-

-

... More
300mm dia R.C.C. pipe (DSR 2018 14.14.4)

100

-

-

... More
INSPECTION CHAMBER:

-

-

-

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:

-

-

-

... More
Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets.

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 2018 19.30.2.1)

15

-

-

... More
Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 2018 19.30.3.1)

20

-

-

... More
Extra for depth beyond 45 cm of brick masonry chamber

-

-

-

... More
For 500x700 mm size

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 2018 19.31.2.1)

15

-

-

... More
For 600x850 mm size

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 2018 19.31.3.1)

20

-

-

... More
Supply, Installation, Testing & Commissioning of 25 KL capacity mild steel horizontal cylindrical underground HSD tank (2.5M dia & 5.5M length) with shell 6mm and end plate 10mm thick suitable for underground installation complete with manhole accessories, fittings, piping inside the tank Decanting hose, bucket filter etc. with paint with inside surface scrapped clean. Tank will be tested at works under hydrostatic pressure of 5 psi before being painted with two coats of Red Oxide Primer as required as per specifications. Liasioning work for getting the HSD Yard layout drawing approval and licence / NOC from concern department.

1

-

-

... More
Supply, Fixing, Testing and Commissioning of M.S. heavy class ERW piping (Class-C) conforming to IS : l239 with necessary clamps, supports, anti vibration mountings, hangers and fittings such as bends, tees, reducers etc. painted as per specifications. (DSR Wet Riser 2019)

-

-

-

... More
80 mm dia (DSR Wet Riser 2019 7.6)

6

-

-

... More
40 mm dia (DSR Wet Riser 2019 7.3)

50

-

-

... More
25 mm dia (DSR Wet Riser 2019 7.1)

60

-

-

... More
32 mm dia (DSR Wet Riser 2019 7.2)

90

-

-

... More
VALVES & STRAINERS

-

-

-

... More
Supply, Fixing and Testing of following valves, strainers, in the H.S.D. Fuel Handling System piping complete with companion flanges, nut bolts, gaskets, supports and painted etc. as per specifications:

-

-

-

... More
Ball valves :

-

-

-

... More
80mm dia.

3

-

-

... More
40mm dia.

8

-

-

... More
32mm dia.

4

-

-

... More
25mm dia.

11

-

-

... More
Non return valves :-

-

-

-

... More
40mm dia (DSR wet Riser 2019 14.1)

4

-

-

... More
Y-strainers :-

-

-

-

... More
40mm dia. (DSR 2018 16.7.4.8)

4

-

-

... More
80mm dia. (DSR 2018 16.7.4.5)

1

-

-

... More
Supply, Laying, Testing & Commissioning of 1 No. 40mm dia M.S. heavy class ERW piping (Class-C) conforming to IS : 1239 complete with fittings such as bends, tees, reducer sets on surface/hume pipe or directly in ground including excavation, sand cushioning, 4 mm PYPCOT protective covering and refilling the trench etc. as required.

-

-

-

... More
In Ground / On surface

150

-

-

... More
Supplying and Laying of 1 No. 25mm dia M.S. heavy class ERW piping (Class-C) conforming to IS : 1239 complete with fittings such as bends, tees, reducer sets on surface/hume pipe or directly in ground including excavation, sand cushioning, 4 MM PYPCOT protective covering and refilling the trench etc. as required.

-

-

-

... More
On surface/ hume pipe.

10

-

-

... More
Supply and Erection of canopy type M.S.Structure made out of 40mm medium class M.S. pipe (Class-B), 25 x 25 x 3 mm angle iron frame work and 14 SWG GI Sheet. Structure shall be grouted in C.C. 1:2:4 foundation for hanging 4 Nos. 9 litre each fire fighting buckets including providing buckets with two coats of anticorrosive paints etc. complete as required.

1

-

-

... More
Supply and Installation of 50ltr capacity Chemical Foam Fire Extinguisher with trolley suitable for Petroleum Fires Protection conforming to IS : 5507.

1

-

-

... More
Supply and Installation of 5 kg. capacity dry chemical powder type fire extinguishers conforming to IS : 2171.

1

-

-

... More
Supply of suitable sizes sign boards as per IPR :1976 and fixing the same at various locations within the petroleum installation complete with painting and installation.

1

-

-

... More
Supply & erection of Flame Proof positive displacement type HSD pump inside the fuel tank yard having mechanical seal complete with all accessories, fixing on M.S. channel including making earthing as required. Head shall be as per actual requirement.

-

-

-

... More
110 LPM

4

-

-

... More
Supply and fixing of flow meter for diesel line as required.

-

-

-

... More
80mm dia.

1

-

-

... More
25mm dia.

3

-

-

... More
Supply, Installation, Testing & Commissioning of 32A Flame Proof out door type isolator switch, M.S. Stand, earthing etc complete as required.

2

-

-

... More
First aid box as approved by St.John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963.

2

-

-

... More
Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work. as required in 2 languages (Hindi & English). (UPPWD SOR-2018, 1134)

2

-

-

... More
Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality. Rubber mat as per IS 15652-2006 to withstand 1.1 KV dielectric strength and 11 KV dielectric strength. (UPPWD SOR-2018, 1136)

100

-

-

... More
Providing and fixing MV danger notice plate of 200 mm x 150 mm made of mild steel at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required. (DSR Elect 2018/ 2.21)

4

-

-

... More
Main DG Panel with suitable PLC Controlller for AMF, Load Management and D.G. Set Controller for Synchronizing (2x1250 KVA+1x500 KVA)

-

-

-

... More
Supply, erection, testing & commissioning of Main DG Control panel with PLC controller, this will be floor mounted, free standing, compartmentalized, indoor duty, dust proof, vermin proof, front operated, electrical panel fabricated, painted and manufactured exactly as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth terminals, earth bus and will be powdered coated finished. All the busbar joint shall be protected by clip on type sleeve. The DG control panel shall use all draw out 3 position withdrawn type breakers suitable for 415 V AC, 3 phase, 50 Hz, 4 wire supply system and will have fault level of 50 KA or as required as per consultant approval. The panel will be made as per detailed specifications and drawings forming part of this document (Under no case temperature of LT Panel shall be more at any point of the panel, otherwise necessary exhaust fan shall be have to provided) Bus bar calculations considering temperature derating, enclosure derating, sleeving derating must be done and submitted for checking. (Operation & Synchronization Logic shall be prepared by manufacturer with coordination of consultants.

-

-

-

... More
One set of Generator control relay for Each D.G. Set with accessories for AMF, Load Management, Synchronizing and Interlocking through micro PLC. (Make of relay - Woodword / Dief) Bus Bar Shall be 5000Amp.

-

-

-

... More
2 Nos. 2000A feeder incomer and Each incomer breaker feeder shall have following:

-

-

-

... More
One number incomer 3P 2000 amps EDO breaker with 400 Amp TP neutral contactor. Each breaker shall have microprocessor based releases for O/C,S/C & earth fault protection with instantaneous.

-

-

-

... More
3 Nos. indicating lamps to show the incoming power along with HRC fuses.

-

-

-

... More
1 Nos. digital AVF Meter with inbuilt Selector Switch & Protective SP MCB (96mm square).

-

-

-

... More
2 No. Load Manager EM 6400 with RS 485 port

-

-

-

... More
1 no. REF relay

-

-

-

... More
Announciation window to cover LLOP, HWT, OIL Pressure, U/V, O/V, U/F, O/F, O/C, E/F, REF relay faults shall be provided. 2 nos phase reversal relay shall be provided.

-

-

-

... More
Engine should trip on LLOP, HWT, oil temp, O/V, O/F and breaker should trip on other faults.

-

-

-

... More
Initially U/V & U/F will be bye passed till oil pressure is picked up.

-

-

-

... More
Indicating lights for ACB ON / OFF, ACB trip, neutral contactor ON, D.G. on mains, D.G. fails to start.

-

-

-

... More
Generator start /stop facility through push button from panel, necessary cranking relay shall be provided.

-

-

-

... More
Suitable battery charger for 24V 360 AH with d.c voltmeter & d.c ammeter. D.C voltmeter and ammeter will be analouge type.

-

-

-

... More
Whenever D.G. stop through PB, load shall be disconnected first.

-

-

-

... More
1 Nos. 800A feeder incomer and Each incomer breaker feeder shall have following :

-

-

-

... More
One number incomer 3P 800 amps EDO breaker with 400 Amp TP neutral contactor. Each breaker shall have microprocessor based releases for O/C,S/C & earth fault protection with instantaneous.

-

-

-

... More
3 Nos. indicating lamps to show the incoming power along with HRC fuses.

-

-

-

... More
1 Nos. digital AVF Meter with inbuilt Selector Switch & Protective SP MCB (96mm square).

-

-

-

... More
1 No. Load Manager EM 6400 with RS 485 port

-

-

-

... More
1 no. REF relay.

-

-

-

... More
Announciation window to cover LLOP, HWT, OIL Pressure, U/V, O/V, U/F, O/F, O/C, E/F, REF relay faults shall be provided. 2 nos phase reversal relay shall be provided.

-

-

-

... More
Engine should trip on LLOP, HWT, oil temp, O/V, O/F and breaker should trip on other faults.

-

-

-

... More
Initially U/V & U/F will be bye passed till oil pressure is picked up.

-

-

-

... More
Indicating lights for ACB ON / OFF, ACB trip, neutral contactor ON, D.G. on mains, D.G. fails to start.

-

-

-

... More
Generator start /stop facility through push button from panel, necessary cranking relay shall be provided.

-

-

-

... More
Suitable battery charger for 24V 360 AH with d.c voltmeter & d.c ammeter. D.C voltmeter and ammeter will be analouge type.

-

-

-

... More
Whenever D.G. stop through PB, load shall be disconnected first.

-

-

-

... More
BUS COUPLER

-

-

-

... More
1 Nos. bus coupler 2000A 4P EDO ACB with over current, short circuit and earth fault releases.

-

-

-

... More
1 Nos. bus coupler 800A 4P EDO ACB with over current, short circuit and earth fault releases.

-

-

-

... More
BUS BAR

-

-

-

... More
Bus Bar shall be suitable for carring 4000A in phases and 2000A in neutral.

-

-

-

... More
OUTGOINGS

-

-

-

... More
Each outgoing feeder shall have electronic Multifunction Meter and ON/ Off/ Trip Indication Lamp. All the ACB / MCCB shall be 50 KA.

-

-

-

... More
3 No. 1250A FP MDO ACB with microprocessor based over current, short circuit, earth fault protections.

-

-

-

... More
3 No. 1000A FP MDO ACB with microprocessor based over current, short circuit, earth fault protections.

-

-

-

... More
1 Nos. 800 Amp FP MCCB.

-

-

-

... More
1 Nos. 630 Amp FP MCCB.

-

-

-

... More
3 Nos. 400 Amp FP MCCB.

-

-

-

... More
3 Nos. 300 Amp FP MCCB.

-

-

-

... More
6 Nos. 200 Amp FP MCCB.

-

-

-

... More
5 Nos. 160 Amp FP MCCB.

-

-

-

... More
2 Nos Fixed type Automatic transfer switch 1250 Amp rating in open frame with  live to live transfer time  200ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS.

-

-

-

... More
1 Nos Fixed type Automatic transfer switch 800 Amp rating in open frame with  live to live transfer time  200ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS.

-

-

-

... More
1 Lot of control wiring

-

-

-

... More
1 Set of designation plates

-

-

-

... More
D.G. Synchronizing Panel described as above.

1

-

-

... More
MAIN L.T. PANEL CUM CAPACITOR PANEL (BLOCK-1)

-

-

-

... More
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Testing & commissioning of Main LT Panel. The panel will be totally enclosed type with, free standing, floor mounted, indoor duty, dust & vermin proof, , front operated, electrical panel fabricated from 2 mm thick CRCA Sheet as per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, ammeter, ammeter selector switch, voltmeter, voltmeter selector switch, indication lamps, CT's, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 70 micron thickness. All the busbar joint shall be protected by clip on type sleeve. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have changeover facility & interlocking through PLC to achieve electrical interlocking, buscoupler switching, auto operation of incommer and bus coupler etc and having following incomming and outgoing Air Circuit Breakers, MCCB as per the drawing and specification.

-

-

-

... More
Each incoming / outgoing breaker shall have microprocessor release mentioned as in specification. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 50 KA.

-

-

-

... More
(Each Incomming / Outgoing MCCB shall have microprocessor release and variable current setting from front, overcurrent & short circuit protection, front extended lockable handle, pad lockable in off position, shrouding on incomer side, termination shall be suitable for aluminium bus bars / cables and as per specification.)

-

-

-

... More
INCOMING

-

-

-

... More
3 No. 1600 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker microprocessor based releases for O/C,S/C & earth fault protection with instantaneous. (For Incommer) (50 KA)

-

-

-

... More
BUSCOUPLER

-

-

-

... More
2 Nos. 1600Amp FP Electrically operated horizontal drawout type Air Circuit Breaker as buscoupler with interlocking arrangement with incomers. (50 KA)

-

-

-

... More
2 Sets of indicating lamps for ON & OFF of bus coupler.

-

-

-

... More
BUSBARS

-

-

-

... More
2000 Amp TPN busbars of aluminium alloy as per SLD.

-

-

-

... More
OUTGOING

-

-

-

... More
Each outgoing feeder shall have electronic Multifunction Meter and ON/ Off/ Trip Indication Lamp. All the ACB / MCCB shall be 50 KA.

-

-

-

... More
3 No. 1250A FP MDO ACB with microprocessor based over current, short circuit, earth fault protections.

-

-

-

... More
5 No. 1000A FP MDO ACB with microprocessor based over current, short circuit, earth fault protections.

-

-

-

... More
1 Nos. 800 Amp FP MCCB.

-

-

-

... More
5 Nos. 630 Amp FP MCCB.

-

-

-

... More
2 Nos. 400 Amp FP MCCB.

-

-

-

... More
3 Nos. 300 Amp FP MCCB.

-

-

-

... More
4 Nos. 200 Amp FP MCCB.

-

-

-

... More
5 Nos. 160 Amp FP MCCB.

-

-

-

... More
1 Nos. 100 Amp FP MCCB.

-

-

-

... More
INSTRUMENTS

-

-

-

... More
3 Nos. digital AVF Meter with inbuilt Selector Switch & Protective SP MCB (96mm square). (One for Each Incomming Breaker).

-

-

-

... More
3 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).

-

-

-

... More
3 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).

-

-

-

... More
3 Sets trip circuit healthy indicating lamp (one set for each incoming breaker).

-

-

-

... More
3 Sets auto trip indicating lamp (one set for each incoming breaker).

-

-

-

... More
3 Set of CT's one of 1600/ 5Amp ratio for APFC relay.

-

-

-

... More
3 Nos. Frequency meter (one for each Incoming Breaker).

-

-

-

... More
3 Nos. master trip relay (one for each Incoming Breaker).

-

-

-

... More
3 Nos. 3 phase, over voltage & under voltage relay.

-

-

-

... More
3 Nos. 3 phase, phase reversal relay with single phasing preventor.

-

-

-

... More
3 Nos. 8 window announciator with hooter, accept & reset push button.

-

-

-

... More
BATTERY & BATTERY CHARGER

-

-

-

... More
1 No. 24V, 72AH SMF Battery with suitable battery charger.

-

-

-

... More
CAPACITOR BANK PANEL (450 KVAR) - 03 SET (ALL CAPACITOR PANEL SHALL BE PART OF MAIN L.T. PANEL) EACH CAPACITOR PANEL SHALL HAVE FOLLOWING-

-

-

-

... More
INCOMING

-

-

-

... More
1 Nos. 1000 Amp FP manually operated horizontal drawout type Air Circuit Breaker with neutral link. (Already considered in Main L.T. Panel)

-

-

-

... More
1 Nos. 0 to 500 Volt digital voltmeter with Voltmeter Selector Switch & Protective SP MCB (96mm square).

-

-

-

... More
1 No. 0 to 1000 Amp digital ammeter (96mm square) with CT's.

-

-

-

... More
1 Sets of phase indicating lights (RYB) with protection fuses.

-

-

-

... More
1 Sets breaker 'ON' & 'OFF' indicating lamp.

-

-

-

... More
12 Step Automatic Power Factor Correction relay (APFC relay).

-

-

-

... More
BUSBARS

-

-

-

... More
1600 Amp TPN busbars of aluminium alloy as per SLD.

-

-

-

... More
OUTGOING

-

-

-

... More
7 Nos. 125 Amp TP MCCB.

-

-

-

... More
4 Nos. 63 Amp TP MCCB.

-

-

-

... More
7 Nos. capacitor duty contactor (one for each 50KVAR capacitor unit).

-

-

-

... More
4 Nos. capacitor duty contactor (one for each 25KVAR capacitor unit).

-

-

-

... More
7 Nos. 50 KVAR Capacitor Bank with 14% detuned reactor.

-

-

-

... More
4 Nos. 25 KVAR Capacitor Bank with 14% detuned reactor.

-

-

-

... More
11 sets of push button stations Red and Green for manual operation of capacitor units with auto/manual selector switches.

-

-

-

... More
1 No. Indicating lamp for each 100 / 50 / 25 KVAR capacitor unit to indicate that the unit is 'ON'.

-

-

-

... More
1 No. Toggle switch for changing automatic to manual operation of capacitor units.

-

-

-

... More
Power factor meter.

-

-

-

... More
Main L.T. Panel cum capacitor Capacitor Panel describe as above.

1

-

-

... More
Supplying, installing by suspension on ceiling/along the wall, testing and commissioning of following capacity Sandwich Type Bus Duct for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with metal clad enclosure having IP-54 rating, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/sq. cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, adopter box and copper flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. (DSR 2018-3.13)

-

-

-

... More
2000 A, Isc = 50 kA for 1 second (DSR 2018 3.13.8)

90

-

-

... More
1250 A, Isc = 50 kA for 1 second (DSR 2018 3.13.6)

150

-

-

... More
800 A, Isc = 50 kA for 1 second (DSR 2018 3.13.4)

50

-

-

... More
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Testing & commissioning L.T. Breaker Panel suitable for 415 Volts 3 phase, 4 wire, 50 Hz A/C supply totally enclosed type with free standing floor mounted dust and vermin proof indoor type fabricated from 2mm thick CRCA sheet complete with Digital AVF Meter with builtin selector switch, phase indicating lamps, ON/Off indication lamp, protection SP MCB for each cubicle suitable for incoming & outgoing for bus duct termination etc complete as required. ACB shall have overload, earth fault & short circuit protection. (Fault level of panel shall be 50 KA.)

-

-

-

... More
2000 Amp FP ACB.

2

-

-

... More
800 Amp FP ACB.

1

-

-

... More
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Tesing & Commissioning of 11KV Outdoor type Package Sub-Station consisting of 11/0.433KV, Oil type transformer, HT 3 way 11 KV RMU, LT Panel inside GI sheet steel enclosure with all interconnections, fully type tested as per the IEC-1330 complete in all respect consisting of following items & as per detailed technical specifications:

-

-

-

... More
11KV, 3 way RMU with 2 No 630A Isolator and 1 No breaker of 200A with self powered IDMT relay, 18KA/3 sec. All the live parts, modules, isolators, earth switches must be sealed within robotically welded single stainless steel tank filled with SF6 gas as insulation having IP67 degree of protection. Each module of the panel should have hinged arc proof cable doors with self interlocking mechanism to the corresponding earth switch, all cable terminations shall be from the front, ring core CTs for metering & protection purposes, self powered microprocessor based numerical 3 O/C & 1 E/F relay for protection. Transformer auxiliary protection relays for OTI & WTI trip & alarm with 12 window annunciation in outgoings. Arrangement for connecting incoming cable and outgoing to primary of transformer.

-

-

-

... More
Multifunction Meter (A, V, KWH, kVAR, PF) in the Line PT panel along with 1set of PT of 11kV/ 110V CL1.0, 50VA.

-

-

-

... More
433V LT Indoor panel with Aluminium Busbars, Fabrication using 1.5/2 MM CRCA sheet steel, Ingress protection IP4X, solidly earthed at substation complete with internal wiring, 1set of LT cast resin CT's, PT's & multifunction meter Load Manager (A, V, kWH, kVA, kVAR), R Y B indication lamps, ON/ OFF/ Trip indication lamps, control MCB's and wiring etc. consisting of following.

-

-

-

... More
The panel shall include 1600Amp. MDO ACB Fixed, 4 pole, 50 KA with microprocessor based O/C, S/C & E/F releases. Breaker to act as Incomer cum outgoing. Ics=Icu for the breaker.

-

-

-

... More
Outdoor type enclosure having modular construction of Galvanized Sheet Steel. The Enclosure shall have IP54 degree of protection for HT and LT switchgear compartment and IP23D degree of protection for Transformer compartment. The enclosure exterior shall be painted with poly urethane paint. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment. Interconnection Between HT switchgear and Transformer using XLPE Single core cable & Interconnection between Transformer and LT switchgear using Busbars. All metallic components shall be earthed to a common earthing point.

-

-

-

... More
1000 KVA, 11kV/ 433V, DYn11, AN, Oil type transformer with off circuit tap changer of -5% to +15% in steps of 2.5 % Transformer. Losses should be as required by Lates IS 1180 Level 2. / ECBC 2017 ECBC Building.

-

-

-

... More
Internal factory connections Between HT switchgear and transformer shall be done using 1Cx3x95Sq.mm XLPE single core copper condutor cables and interconnection between transformer and LT switchgear using tinned copper busbars. All metallic components shall be earthed to a common earthing point.

-

-

-

... More
Unitised substation as described above

3

-

-

... More
Supplying of 11 KV (E) grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required. (UPERC PAGE 29)

-

-

-

... More
3C x 185 Sqmm, 11 KV (E) XLPE

300

-

-

... More
Supply & making of INDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core XLPE aluminium conductor cable of 11 KV grade as required. (UPERC PAGE 29)

-

-

-

... More
3C x 185 Sqmm, 11KV XLPE

8

-

-

... More
Supply & making of OUTDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core XLPE aluminium conductor cable of 11 KV grade as required. (UPERC PAGE 29)

-

-

-

... More
3C x 240 Sqmm, 11KV XLPE

1

-

-

... More
Laying of one number XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. (DSR 2018-8.4)

-

-

-

... More
Above 120 sq. mm and upto 400 sq. mm (DSR 2018-8.4.2)

300

-

-

... More
Supply, Installation, Tesing & Commissioning of 2kg capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube, Novec 1230 , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation

20

-

-

... More
Supply, Installation, Tesing & Commissioning of 4kg capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube, Novec 1230 , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.

10

-

-

... More
Supply, Installation, Tesing & Commissioning of Linear pneumatic heat Detection Tube with all necessary fittings & supports.

1275

-

-

... More
Supply, Installation, Tesing & Commissioning of Audio / Video alarm

40

-

-

... More
Supply, Installation, Tesing & Commissioning of 1x150 Ltr (or as per design calculation) CCOE approved high pressure, seamless Cylinders having suitable 150 ltr water capacity & suitable to store required Novec 1230 gas at 34.5 bar pressure complete with concave bottom & neck ring, complete with valve assembly, low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV,Electrically operated control head for main cylinder ,Pressure operated control head for slave,manually operated actuator to actuate the gas flooding process,flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping,discharge manifold & system piping , Nozzle(as per OEM) , Flexible actuation hose, warning signage , Gas release panel, Manual release, abort , sounder complete as required . (Main & Standby system)

1

-

-

... More
Supply, installation, testing and commissioning of ceiling mounted Tube Axial flow fans with adjustable pitch blade, MS / GI long casing (2mm thick up to 800 mm dia fan, 3 mm thick from 900 to 1250 mm dia & 4 mm thick above 1300 mm dia) , cast aluminium alloy impeller complete with TEFC (IE3) Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, three phase A.C supply with support, mountings, vibration isolators, fire retardant flexible canvass connector 150 mm deep (Inlet & Outlet as required), bird screen (Inlet & Outlet as required) etc. & of following capacity. The complete fan along with motor shall be suitable for 250 °C temperature rated for 2 hours. Fan outlet velocity shall be limited to maximum of 16 m/sec. Static Pressure, Fan & Fan motor KW given below are for guideline & actual Dia / KW shall be as per manufacturer selection based on maximum 16 m/sec outlet velocity & static pressure shall be as per shop drawings.

-

-

-

... More
8,000 CFM (20mm st. pr, 700 mm Dia Axial Fan, 2.2 KW, 1450 RPM Fan Motor, Direct Driven)

40

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.