Uttar Pradesh Projects Corporation Limited Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

Uttar Pradesh Projects Corporation Limited - UPPCL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date2 May 2025
Closing Date14 May 2025
Tender Amount₹ 1,19,65,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavating , Supplying , stacking and filling of local earth ( including Royalty) by mechanical transport up to lead of 5.0 KM also including ramming and watering of the earth in layers not exceeding 20cm in foundation trenches, plinth, side of foundation etc. complete for all lift

47.44

493

23421.13

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

38.83

1496

58119.58

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).

67.03

4800

321806.34

... More
Brick work with common burnt clay (non modular)bricks of class designation 150 in foundation and plinth in :cement mortar1:6(1 Cement:6 coarsse sand)

61.77

6302

389307.28

... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).

43.57

289

12616.13

... More
Applying a coat of residual petlaeum bitumen of grade of VG-10 of approved quality using 1.7kg per square meter on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

43.57

103

4487.71

... More
Treatment of soil under existing wall below concrete or masonry apron using chemical @ 1 liters per linear hole,300mm apart including drilling 12 mm diameter holes and plugging with cement mortor 1:2(1cement:2 coarse sand) to match the exiting floor with chlorpyriphos / lindane E.C.20% with 1% concentraction

356.44

218

77889.27

... More
providing and laying in posistion specified grade of rainforced cement concret, excuding the cast of centering ,shuttering,finishing and rainforsment all work of up to plinth lavel -1:1.5:3(1cement :1.5 coarse send (zone III),:3 graded stone aggregate 20mm narmal size) derived from natural sources

15

6375

95628.3

... More
Reinforced cement concrete work in wall (any thickness) ,inciuding attached pilasters, planth and string courses , fillets, columns, pillars, abutbuttersses,plinth and stringcourses ,fillets, columnspillars,piers, abutments posts and struts etc. above plinth level up to floor five lavel, up to floor five lavel, excluding cast oh centering , shuttering, finshing and reinforcement:1:1.5:3(1 cement:1.5 coarse send :3 graded stone aggregate

7.71

7648

58973.02

... More
Providing and laying in position specified grade of rainforced cement concrete excluding the cast of centering shuttering finishing and reinforcement - All work up to plinth level:1:1.5:3(1 cement:1.5 coars send:3 graded stone aggergate 20mm nominal size)Plinth Beam

11.97

6375

76311.38

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). For Lintel

1.68

8108

13622.78

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). For Slab

31.71

8108

257130.05

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). For Beam

15.58

8108

126335.1

... More
Steel reinforcement for RCC work including straightening,cutting, bending placing in position and binding all copmleet up to plinth level. Thermo-Mechanically Treated bars of grade Fe 500D or More

134.65

7601

1023476

... More
Centering and shuttering including ,propping etc.and removal of from for:

-

-

-

... More
For column,footing, bases of columns, etc. for mass concrete

31.14

276

8606.47

... More
suspended floor, roofs, landings, balconies and access platfrom

253.76

653

165832.16

... More
lintel,beams,plinth beams, girders, bressumers and cantievers

246.04

519

127694.76

... More
Columns,pillars,Piers, Abutments,Posts and Struts

129.87

677

87986.93

... More
EXTRA FOR ADDITION HEIGHT IN CENTERING &SHUTTERING

283.45

270

76772.43

... More
Brick work with common burnt clay (non modular)bricks of class designation 150 in foundation and plinth in :cement mortar1:6(1 Cement:6 coars send)

97.08

10370

1006767.17

... More
Brick work with common burnt clay (nanmodular) bricks of class designation 150 in superstucture above plinth lavelup to sendfloor v lavel in shapes and size in Cement mortar 1:4 (1 cement 4 coarse)

3.69

10596

39102.82

... More
Steel work welded inbuilt up sections/framed work,including cutting hoisting, fixing in position and applying a priming coat of appr required. steel primer using structural steel etc. as required . In gratings, frames, guard,bar ladder,railing, brackets, gates and similar works

2824.2

121

343535.69

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.

265.88

1187

315671.35

... More
12mm cement plaster of mix 1:6 (1cement : 6 coarse sand)

379.77

242

91980.29

... More
15mm cement plasteron rough side single or half brick wall of mix 1:6 (1 cement : 6 coarse send)

417.01

278

116191.5

... More
6mm cement plaster of mix 1:3(3 fine sand : 1 cement )

258.88

211

54817.84

... More
15 mm cement plaster in single coat on plinth 1 cement : 4 coarse sand in plinth

177.45

290

51494.22

... More
Add for plaster groove in plastered surface or moulding to R.C.C. projections.

608.16

55

33600.84

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be spcified by the manufactuer) of 1st quality conforming to IS:15622of approved make in colours white,ivory,Grey,Fume Red Brown, laid on 20 mm thick cement mortar1:4(1 cement 4 coarse send ),jointing with grey cement slurry @3.3kg/sqm including grouting the joints with white cement and matching pigments etc.compete.

6.01

937

5633.47

... More
Providing and fixing 1st quality ceramic glazed wall tile conforming to IS:15622(thickness to be specified by the manufacturer,)of approved make,in all colours, shades except burgundy, bottle green,black of the any size as aproved by Engineer-in-charge ,in skirting, risers of steps and dados,over 12mm thick bed of cement mortor1:3(1 cement 3coarse send )and jointing with grey cement slurry @3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

33.81

893

30213.29

... More
40mm thick cement concrete flooring with cement concrete 1:2:4(1 cement :2 coares send:4 aggregate)20 mm nominal size complete nosing steps etc finish with a floating coad of neat cement, including cement slurry bu excluding the cast of

255.84

432

110745.46

... More
cement plaster skirting to 30 cm height with cement mortar1:3(1cement3coaresend)finshing with a floating coat of neat cement 18 mm thick

12.27

466

5725.18

... More
25mm thick cement concreate florring 1:2:4:(1 cement 2 coare send 4 graded stone aggregate of size 20mm below)by laid over concrete finishedwith floating code a neat cement (base concrete to be paid separatey)including fixing of glass strips

69.59

270

18827.57

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer

915.61

130

119798.41

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

664.8

120

80168.23

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

1580.41

109

173813.49

... More
Painting with synthetic enamel paint of approved brand and manufacture of requerd clour to give an even shade:Two are more coats on new work over an under cast of suitable shade with ordinary paint of approved brand and manufacture (steel surface)

43.63

159

6957.24

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

4

210

840.8

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipe 110mm daimiter

19.9

265

5293

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Coupler

-

-

-

4

95

383.84

... More
Bend 87.5*

-

-

-

... More
110 mm band

4

105

423.84

... More
Shoe (plain)

-

-

-

... More
11 Shoe0mm

4

92

371.68

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. 110mm

12

261

3140.16

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

4

38

154.2

... More
PLUMBING WORKS

-

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests

8

4769

38156

... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer

1

2791

2791.3

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. a) 32mm dia (for wash basin)

1

84

84.26

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

1

1133

1133.24

... More
Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms.

5

499

2498.25

... More
Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms

5

118

593.25

... More
Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to IS:8931. 15 mm nominal bore

8

1425

11400

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

6

210

1261.2

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter

77

265

20480.46

... More
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.

-

-

-

... More
Bend 87.5 degree

-

-

-

... More
110 mm Bend

12

105

1271.52

... More
Shoe (Plain)

-

-

-

... More
110 mm Shoe

12

92

1115.04

... More
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

12

261

3140.16

... More
Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.

-

-

-

... More
a) 110mm dia P.V.C. pipe

70

684

47880

... More
b) 90mm dia P.V.C. pipe

50

617

30875

... More
Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90 mm

10

266

2660

... More
Providing and fixing terminal guard.

-

-

-

... More
a) 110mm

8

80

646

... More
b) 90mm

8

71

570

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.

-

-

-

... More
110mm bend

10

218

2185

... More
90 mm bend

10

204

2042.5

... More
Single tee with door

-

-

-

... More
90x90x90 mm

8

266

2128

... More
110x110x110 mm

8

370

2964

... More
90x90x90 mm

8

247

1976

... More
110x110x110 mm

8

332

2660

... More
Providing and fixing clean out plug 110 mm dia.

10

133

1330

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall a) 25mm dia nominal bore (medium duty)

65

283

18395

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
a) 15mm dia nominal bore

130

350

45609.2

... More
b) 20mm dia nominal bore

40

378

15155.6

... More
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. a) 15mm nominal bore

7

68

482.23

... More
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore

7

357

2500.26

... More
Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15mm nominal bore

8

563

4504.64

... More
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 a) 15mm nominal bore

14

404

5666.5

... More
Providing and fixing gun metal gate valve with wheel of approved quality.

-

-

-

... More
a) 25mm dia nominal bore

5

438

2193.25

... More
b) 32mm dia nominal bore

3

486

1458.03

... More
Providing and fixing brass stop cock of approved quality. a) 20 mm nominal bore

5

267

1336.25

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Capacity 3000 litre

3000

7

23250

... More
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter.

80

248

19855.2

... More
Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.

-

-

-

... More
a) 110mm dia P.V.C. pipe (for External sewer)

15

750

11257.5

... More
b) 150mm dia P.V.C. pipe (for External sewer)

91

997

90772.5

... More
Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects.

5

1923

9618.75

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line

5

9000

45001.85

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar

8

383

3071.12

... More
ELECTRIFICATION WORKS

-

-

-

... More
Point wiring in PVC conduit, with paino type switch:-

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

40

1079

43184

... More
Power plug wiring in PVC conduit (2 x 4 Sq.Mm.):- Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

80

245

19664

... More
Circuit/ Sub main wiring in PVC conduit:-

-

-

-

... More
Wiring for circiut/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.

70

171

12002.9

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth earth wire.

140

202

28333.2

... More
2 X 4 sq. mm + 1 x 4 sq. mm. Earth wire.

80

245

19664

... More
2 x 6 sq.mm. + 1 x 6 sq.mm Earth wire

80

323

25845.6

... More
4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire

30

554

16646.7

... More
4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire

30

739

22188

... More
S/F modular type electronic fan rgulator :- Supply and fixing two module stepped type electronic fan regulator on thr existing modular plate switch box including connections but excluding modular plate etc. as required.

12

271

3258.72

... More
S/F modular type blanking plate :- Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

5

29

147.2

... More
Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required :

-

-

-

... More
20 mm.

50

94

4710

... More
25 mm.

20

106

2134.2

... More
32 mm.

10

135

1354.1

... More
Supplying and fixing 5 amps. to 32 amps. Rating, 240 volts 'C' series, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole

18

188

3391.2

... More
Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required.

5

9

47.85

... More
Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A

1

1691

1691

... More
Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A

1

1700

1700.5

... More
Supply and fixing of 40 Amp. FP MCB (10 KA) C Curve. CAT A

1

2161

2161.25

... More
Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A

1

2175

2175.5

... More
Supplying and fixing following rating, four pole, (three phase & neutral) 415 volts, residual current breaker (RCCB), having a sensivity current upto 300 miliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required :

-

-

-

... More
40 amps.

1

2346

2346.12

... More
63 amps.

1

2113

2113.57

... More
Supplying and fixing following way, horizontal type TP&N, sheet steel MCB distribution board, 415 B on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolatdrs). 6 way (4 + 18) double door

1

3660

3660.48

... More
Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/ coke and salt as required.

1

5498

5498.81

... More
Supplying and laying 25 mm x 5 mm. G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

10

105

1059.7

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

20

211

4224.2

... More
Providing laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fitting including trenching (75 cm deep) and re-filling etc as required. 100 mm dia

10

1272

12728.2

... More
Providing and fixing M.V. danger notice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both side and with inscription single red colour on FRLSont side as required.

1

197

197.96

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceilling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.Sm sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

12

155

1866.12

... More
Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

26

151

3941.6

... More
Installation, testing and commissioning of ceiling fan includig wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

12

203

2437.32

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep

2

331

662.32

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 6 star rated ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: 8, 3 nos. blades, 30 cm long down rod, 2 nos. conopies, shackle kit, safety kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

12

2009

24108.84

... More
Supply and fixing of recessed 18 watt LED Light with Metal heavy duty Box type batten Light fitting & 18 wat LED Polycarbonate tube light complete including tube complete in all respect.

26

1757

45695

... More
Supply of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing / Copper motor / Capacitor etc.) Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 300mm sweep

2

3420

6840

... More
L.T.PANEL AND UPS

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of Sub Panel ( Light ) fabricated out of 16 SWG CRCA sheet steel, wall / floor mounting type. The sheet steel shall undergo minimum seven tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect.

-

-

-

... More
The MCCB,s shall be Ics = 100% Icu, with rotary handle & pad locking arrangment with trip setting as per load requirement. TP MCCB shall be with solid isolable neutral link. The breaking capacity specified is lcs value, All MCCB's shall be thermomagnetic type. All outgoing MCB's shall be C type with 10 KA breaking capacity.

-

-

-

... More
The above board shall be complete with 3 nos. phase indicating lights, flush mounted Ammeter, Voltmeter, CT's, PT's, selector switches, protective fuses etc. at incomer with all inter connetions by min. 2.5 sq. mm. Copper wires.

-

-

-

... More
INCOMER :160 AMP FP MCCB (35 KA)

-

-

-

... More
BUS BAR :200 AMP TPN Anuminium

-

-

-

... More
OUT GOINGS :5 nos. 63 AMP DP MCB

-

-

-

... More
OUT GOINGS :10 nos.63 AMP FP MCB

1

137750

137750

... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Voltes grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt brick on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.

-

-

-

... More
16 sq. mm 4 core

50

133

6650

... More
35 sq. mm 3-1/2 core

90

266

23940

... More
50 sq. mm 3-1/2 core

20

351

7030

... More
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required

-

-

-

... More
16 sq. mm 4 core

1

227

227.4

... More
3.5 X 35 sq. mm (35mm)

2

271

543.12

... More
SEPTIC TANK & SOAK PIT

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil.

-

-

-

... More
In all kind of soil

55.75

183

10227.34

... More
Extra additional lift above 1.5 m

20.75

89

1854.43

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 ( 1 Cement : 4 coars and : 8 graded stone aggregate 40 mm nominal size)

2.38

4800

11426.21

... More
Brick work with common burnt clay (non modular) bricks of class 150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

14.77

8495

125478.09

... More
Cement plaster 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster.

33.63

413

13917.44

... More
40 mm thick cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size: finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.

10.72

432

4640.37

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15* landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ). Slabs

2.08

8108

16866.3

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform

13.84

653

9044.44

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

1.62

7601

12313.64

... More
Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.

8

383

3071.12

... More
Providing and fixing 150 mm S.C.I. tee the inlet and outlet of septic tank.

2

589

1179.9

... More
Providing & fixing 75mm dia vent pipes.

1

835

835.86

... More
Providing & fixing of 75mm dia cast iron terminal guard.

1

285

285.26

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.

-

-

-

... More
M.D. -10- Circular shape 500mm internal diameter

2

826

1652.84

... More
L.D. -2.5- Circular shape 450mm internal diameter

2

824

1648.68

... More
Making soak pit 2.5 m diameter 3.0 meter deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

18931

37863.22

... More
DAY TOILET

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dresing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.

10.74

183

1970.25

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, conslidating and dressing complete.

0.65

1496

972.9

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

3.39

4800

16275.15

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) (Plinth Beam)

0.43

6375

2741.34

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15* landing, balconies, shelves, chajjas, lintels, bands, plan window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). Lintels

0.45

8108

3648.96

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15* landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ). Slabs

0.11

8108

891.97

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15* landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggreagate 20 mm nominal size). Beams

0.11

8108

891.97

... More
Centering and shuttering including strutting, propping etc. and removal of form for:

-

-

-

... More
Suspended floors, roofs, landings, balconies and access platform

12.6

653

8234.1

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

16.48

519

8553.12

... More
Brick work with common burnt clay ( non modular) bricks of class designation 150 in foundation and plinth in: cement mortar 1:6 ( 1 cement : 6 coarse sand)

5.78

6302

36428.62

... More
Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 ( 1 cement : 6 coarse sand)

3.99

10370

41378.26

... More
Brick work with common burnt clay ( non mudular) bricks of class designation 150 in superstructure above plinth level up to floor V in all shapes and sizes in: Cement mortar 1:4 ( 1 cement : 4 coarse sand

0.88

10596

9325.33

... More
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quailty using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lighty soaked in kerosene oil.

3.41

103

351.23

... More
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints, surrounding of pipes and conduits etc. complete(plinth area of the building at ground floor only shall be measured as per I.S.6313( Part II 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used. The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonary & foundation 5 litres per sq.m. (2) back fill in immediate contract with foundation 7.5 litre per sq.m (3) treatment of top surface of plinth filling 5 liters per sq.m (4) treatment of soil along external parameter of building 7.50 lire per sqm. (For payment plinth area to be measured as per IS Code.)

7.31

218

1597.38

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

2.62

7601

19914.65

... More
Providing and fixing 1 mm thick M.Sm sheet door with frame of 40x40x6 mm angle iron and 3mm M.S. gusset plates at the junctions and corners. All necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces

3.6

4090

14726.74

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally fininshing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.

-

-

-

... More
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. "All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thckness of 120 mm and minimum thickness at khurra as 65 mm.

9.96

1187

11825.21

... More
12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)

17.45

242

4226.39

... More
15 mm cement plaster on rough side of single or half brick wall of mix 1:6 ( 1 cement : 6 coarse sand)

17.45

278

4862.09

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

6.96

211

1473.78

... More
15 mm cement plaster in single coat on plinth 1 cement: 4 coarse sand in plinth

16.16

290

4689.47

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more ( thickness to be specified by the manufacture), of 1st quality conforming to IS : 15622, of approved make, in colours White, Lvory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.

4.32

937

4049.35

... More
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 ( thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete

28.98

893

25897.11

... More
40 mm thick cement concrete flooring with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, including cement slurry, but excluding the coat of nosing of steps. etc. complete.

2.64

432

1142.78

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement :3 coarse sand), finished with a floating coat of neat cement. 18 mm thick

1.98

466

923.87

... More
25 mm thick cement concrete flooring 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of size 20 mm and below) by laid over base concrete finished with floating coat of neat cement (base concrete to be paid separately) including fixing of glass strips

12

270

3246.6

... More
distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work ( two or more coats) over and including water thinnable priming voat with cement primer

14.93

130

1953.44

... More
finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work ( Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

32.93

120

3971.03

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.

47.86

109

5263.64

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (Steel surface)

7.92

159

1262.92

... More
C/O Apron drain of width 230 mm and depth as per required of site but minimum 230 mm with neat finish & required slope as per apporoved by E/I.

13.33

1053

14046.09

... More
Making hurras 45x4 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x 1m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

2

210

420.4

... More
Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter

5.7

265

1516.09

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Coupler

-

-

-

2

95

191.92

... More
Bend 87.5°

-

-

-

... More
110 mm bend

2

105

211.92

... More
Shoe (Plain)

-

-

-

... More
110 mm Shoe

2

92

185.84

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticied - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

4

261

1046.72

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

2

38

77.1

... More
BATHING PLATEFORM

-

-

-

... More
Earth work in excavation by machanical means ( Hydraulic excavator) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan), including dressing on sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated oil as directed, within a lead of 50 m. All kinds of soil.

11.52

183

2113.34

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete

0.81

1496

1212.38

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 ( 1 cement : 4 coarse : 8 graded stone aggregate 40 mm nominal size)

3.54

4800

16995.29

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) (Plinth Beam)

0.47

6375

2996.35

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15* landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded aggregate 20 mm nominal size). Lintels

0.49

8108

3973.31

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15* landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering. shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). Slabs

1.34

8108

10865.79

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15* landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, exculding the cost of centering. shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Beams

0.11

8108

891.97

... More
Centering and shuttering including strutting, propping etc. and removal of from for:

-

-

-

... More
Suspended floors, roofs, landings, balconies and access platfrom

13.92

653

9096.72

... More
Lintels beams, plinth beams, girders, bressumers and cantilevers

17.89

519

9284.91

... More
Brick work with common burnt clay (non modular) bricks of class designation 150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

6.06

6302

38193.33

... More
Brick work with common burnt clay ( non modular ) bricks of class designation 150 in superstructure above plinth level up to floor V in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)

4.28

10370

44385.7

... More
Brick work with common burnt clay ( non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 ( 1 cement : 4 coarse sand)

1.1

10596

11656.67

... More
Applying a coat of resifual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

3.75

103

386.25

... More
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloum pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints, surrounding of pipes and condulyd etc.complete (plinth area of the building at groung floor only shall be measured as per I.S.6313 (Part II 1981 ) ldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used. The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonary & foundation 5 litres per sq.m. (2)back fill in immediate contract with foundtion 7.5 litre per sq.m (3) treatment of top surface of plinth filling 5 liters per sq.m. (4) treatment of soil along external parameter of building 7.50 lire per sqm. (For payment plinth area to be measured as per IS code).

8.41

218

1837.75

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

2.92

7601

22194.95

... More
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 amm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces

3.6

4090

14726.74

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 1645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoinng walls upto 300 mm height including rounding of junctions of walls and slabs.

-

-

-

... More
(c ) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-in-charge. (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charege invluding laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep.

-

-

-

... More
( e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. "All above operations to be done in order and as directed and specified by the Engineer-in-charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

11.28

1187

13392.41

... More
12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)

18.42

242

4461.32

... More
15 mm cement plaster on rough side of single or half brick wall of mix 1:6 ( 1 cement : 6 coarse sand)

18.42

278

5132.36

... More
6 mm cament plaster of mix 1:3 ( 1 cement : 3 fine sand)

8.04

211

1702.47

... More
15 mm cement plaster in single coat on plinth 1 cement : 4 course sand in plinth

17.33

290

5028.99

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more ( thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc, complete.

5.4

937

5061.69

... More
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15600 ( thickness to be specified by the manufacture), of approved make, in all colour, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

34.02

893

30400.95

... More
40 mm thick cement concrete flooring with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.

2.64

432

1142.78

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 ( 1 cement : 3 coarse sand), finished with a floating coat of neat cement 18 mm thick

1.98

466

923.87

... More
25 mm thick cement concrete flooring 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of size 20 mm and below) by laid over base concrete finished with floating coat of neat cement ( base concrete to be paid separately) including fixing of glass strips.

12.54

270

3392.7

... More
Distermpering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work ( two or more coats) over and including water thinnable priming coat with cement primer

16.51

130

2160.17

... More
Finishing walls with Premium Acrylic Smooth exterior pain with silicone additives of required shade : New work ( Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

34.64

120

4177.24

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

51.15

109

5625.48

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture ( Steel surface)

7.92

159

1262.92

... More
C/O Apron drain of width 230 mm and depth as per required of site but minimum 230 mm with neat finish & required slope as per apporoved by E/I.

13.33

1054

14053.42

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x 1m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

2

210

420.4

... More
Providing and fixing on wall face unplasticise Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter

5.7

265

1516.09

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticise Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Coupler

-

-

-

... More
110 mm

2

95

191.92

... More
Bend 87.5°

-

-

-

... More
110 mm bend

2

105

211.92

... More
Shoe (Plain)

-

-

-

... More
110 mm Shoe

2

92

185.84

... More
Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required lengh, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm diameter

4

261

1046.72

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

2

38

77.1

... More
DEMOLISH BOUNDRY WALL

-

-

-

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge.

94.7

2502

237018

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar

74.43

1451

108070.87

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.

169.13

186

31463.25

... More
BOUNDARY WALL

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.

84.05

183

15418.97

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).

7.85

4800

37683.77

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :

9.45

6375

60245.17

... More
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Foundation , footing , base of columns etc.

11.51

6374

73371.99

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) For Column

7.23

7648

55300.82

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) For Footing/ Beam

1.99

7648

15219.88

... More
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning/centering arrangement and support plates as per ASTM B221-02. The material shali be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Wall Joint of 100 mm gap

12.23

3739

45731.03

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Footing

27.7

276

7654.9

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers. Beam

41.07

518

21313.28

... More
columns , pillere etc.

83.82

677

56783.02

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars. Fe-500 D

5198.17

76

395060.92

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

16.96

8495

144083.17

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement: 6 coarse sand)

56.75

10370

588525.31

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)

175.33

242

42459.67

... More
15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand)

160.73

278

44784.2

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).

175.33

120

21141.29

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

336.05

109

36955.42

... More
Add 7% Hindrance Charges

1

663404

663404.63

... More
GST Extra as applicable

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.