Uttar Pradesh Projects Corporation Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Projects Corporation Limited - UPPCL Tender
Civil And Construction
Building Construction
Eprocure
Opening Date7 Jan 2023
Closing Date12 Jan 2023
Tender AmountRefer Documents
Costs
EMD
₹ 65,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_UPPRC_765092_1Bid Award Id
ViewTender No
25/PM-10/UPPCL/2022-23Tender Authority
Uttar Pradesh Projects Corporation Limited ViewPurchaser Address
-Website
http://http://upprojects.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree (a) Shoe (Plain) 110 mm Shoe
15
-
90.22
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
15
-
37.46
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
15
-
193.48
Providing and fixing gun metal gate valve with wheel of approved quality. (a) 25mm dia nominal bore
5
-
394.13
(b) 32mm dia nominal bore
2
-
460.8
(c) 40 mm nominal bore
1
-
537.82
(d) 50 mm nominal bore
1
-
689.08
Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. (a) Capcity in Per Liters
5000
-
6.98
Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes. a) 110mm dia P.V.C. pipe
158
-
557.46
b) 90mm dia P.V.C. pipe
237.5
-
467.5
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. (a) 110mm bend
24
-
200.17
(b) 90 mm bend
20
-
187.63
Coupler (a) 110mm
24
-
139.75
(b) 90mm
20
-
129.77
Single tee with door (a) 90x90x90 mm
19
-
224.68
(b) 110x110x110 mm
14
-
303.43
Electrica
lWiring points for light with 1.5 sqmm.FRLSH PVC insulated multistrand single core copper condutor cable heavy guaged rigid steel conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box, piano type & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet ect complete in all respect as directed including matching colour wash.
75
-
769.5
Same as above item but for fan and light duty exhaust fan.
32
-
858.8
Same as above item but for 5 amp plug point with piano type switch and socket etc. Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points.
50
-
400.9
Addition for light / fan points with modular type switch in place of piono type switch.
176
-
41.8
Addition for plug points with modular type switch in place of piono type switch.
64
-
78.85
Add for HPMV/Exhaust fan point with modular type switch in place of piano type switch.
11
-
44.65
Supply and wiring of submiain with two number 4 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with one number 14 SWG copper earth continuity wiere including matching colour wash etc. complete in all respect.
1109.8
-
209.95
Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
124
-
193.8
Supply and wiring of submiain with 4 number 10 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with two number 10 SWG copper earth continuity wiere including matching colour wash etc. complete in all respect.
96.5
-
605.15
Supply and wiring of submain 4 number 16 sqmm . PVC insulated 1100 V grade single core copper conductor cable in 40mm dia PVC conduit along with two numbers 10 sqmm single core PVC insulated copper conductor cable as earth contunity wire etc. complete in all respects.
15
-
686.85
Supply and fixing and concealing of 20mm dia. 16 SWG (1.5 mm) thick rigid steel conduit pipe in the wall including cutting of brick work, laying of conduit and fixing it with M.S. hooks and then plastering with cement, sand mortar finished to the level, with matching colour wash including cost of proper threading of the conduit & providing necessary socket, bends and chuck nuts and as directed by the Engineer in charge with the supply of all material labour and T&P required for proper completion of work.
1382
-
126.35
Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects.
28
-
133
Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
21
-
185.25
Supply fixing of electronic fan regulator(Modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
28
-
491.15
Supply and Ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS: 374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volt 50Hz, 1-ph AC the fan assemble should consist of down rod blades, shackle canopies etc and with double ball breaing system BEE 5 star rated-1200 mm sweep
28
-
1710
Supply & fixing of LED Tube Light with batten suitable for up to 1 x 22 watt LED tube light complete including tube etc on surface complete in all respects.(CAT: AAA)
73
-
1130.5
Supply and fixing of 16 gauge M.S. drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect.
10
-
769.5
Supply and fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects. 6 Way TPN
2
-
3087.5
Supply and fixing of 6Amp to 32 Amp(10 KA) MCB in existing MCB, DB complete with connections as required.
12
-
247
Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge. a) 40 Amp. 4 Pole MCB
1
-
1619.75
b) 63 Amp. 4 Pole MCB (10 KA)
1
-
2175.5
Supply and fixing of power plug with 15A/250 V flush type modular switch and 5 Pin 15 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work.
54
-
323
MAIN L.T. PANEL Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.
-
-
-
Phase to phase - minimum 20mm, Phase to neutral-minimum 15mm Main L.T. Panel Incoming : 400 Amp. MCCB-1 Nos. Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 400 A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 200 Amp. MCCB-2 Nos, 100 Amp MCCB- 1 No 63 Amp MCCB-1 No
1
-
193658.45
SUB PANEL (First & Second floor) Incoming : 200 Amp. MCCB-1 No MCCB-1 Nos. Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 400 A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 200 Amp. MCCB-2 Nos, 100 Amp MCCB- 1 No 63 Amp MCCB-1 No
2
-
131166.5
S & F surface/Flush mounting 4ways V TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge.
3
-
8132
S&F of 40Amp 4 pole MCB (25 KA) (10ka)
5
-
2161.25
Providing & Fixing of LED Bulb
71
-
237.5
Rain Water Harvesting
Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (a) In all kind of soil upto 1.5m depth
254.16
-
144.17
(b) In all kind of soil upto 1.5m to 3.0m. depth
194.49
-
215.83
(c) In all kind of soil upto 3.0m to 4.5m. depth
129.66
-
287.5
Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
4.83
-
5320
First Class brick work in 1:6 cement and coarse sand of 2.25 F.M. mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse sand)
71.67
-
4398.5
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Beam excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item
2.07
-
7911.44
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Slab excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item
8.82
-
7911.44
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks.
10.17
-
5871
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: (a) With 20x20mm square bar
39
-
334.71
20mm thick plaster with proportion of 1:3 cement & coarse sand
169.56
-
199.5
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 560 mm internal diameter
9
-
1166.57
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually.
75
-
406.14
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (a) 150 mm nominal size dia
75
-
591.53
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
21.45
-
1051.66
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
21.45
-
1051.66
Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.
21.45
-
1051.66
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge.
3.99
-
1187.34
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter.
399
-
288.72
Providing, laying and joining P.V.C pipes with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100mm diameter
336
-
232.75
b) 150mm diameter
63
-
308.75
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) upto haunches of P.V.C Pipes including bed concrete as per standard design. a) 150mm diameter
336
-
498.89
b) 200mm diameter
63
-
586.98
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
42
-
7363.61
Constructing masonry Chamber 90x90x10 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
3
-
13740.75
GST Extra as per applicable
-
-
-