Uttar Pradesh Projects Corporation Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Projects Corporation Limited - UPPCL Tender

Works
Eprocure
Opening Date19 Sep 2024
Closing Date7 Oct 2024
Tender Amount₹ 7,01,44,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Second Floor

1.99

13479

6773.86

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete .R.C.C. columns (Concrete of M-25 grade with minimum cement content of 330 kg /cum ) R.C.C. FOOTING

15.32

105467

6884.3

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete .R.C.C. columns (Concrete of M-25 grade with minimum cement content of 330 kg /cum )

-

-

-

... More
First Floor

46.87

382950

8170.49

... More
Second Floor

25.24

206223

8170.49

... More
As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete) [M-20]

-

-

-

... More
First Floor

115.89

799268

6896.79

... More
Second Floor

91.72

638899

6965.76

... More
As in item 6 but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) [M-20]

-

-

-

... More
First Floor

93.1

659780

7086.79

... More
Second Floor

105.18

752842

7157.66

... More
Same as in item no. 11 above but in super-structure above plinth level including necessary cutting and moulding of brick work as required & also including honey combed brick work in thickness of wall more than one brick and for extra labour to above items.

-

-

-

... More
First Floor

240.76

1306002

5424.5

... More
Second Floor

185.91

1018554

5478.75

... More
Same as in item no. 12 but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. Second Floor

9.12

52328

5737.81

... More
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.

-

-

-

... More
Above Plinth Lvl.

385.92

2702393

7002.47

... More
Second Floor

304.94

2135333

7002.47

... More
15mm thick cement plaster on rough side of single or half brick wall of mix in 1:4 (cement & coarse sand) in plinth.

58.8

16692

283.89

... More
12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chambers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 6 coarse sand

-

-

-

... More
Ground Floor

709.26

74117

104.5

... More
First Floor

777.24

81221

104.5

... More
Second Floor

847.2

88532

104.5

... More
15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 sand

-

-

-

... More
Ground Floor

2445.6

657450

268.83

... More
First Floor

1957.58

526256

268.83

... More
Second Floor

1254.75

337314

268.83

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

-

-

-

... More
Ground & First Floor

1065.1

25296

23.75

... More
Second Floor

386.82

9186

23.75

... More
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).

171.36

34186

199.5

... More
Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete.

-

-

-

... More
Ground Floor

158.4

210672

1330

... More
First Floor

564.98

751423

1330

... More
Second Floor

455.69

612128

1343.3

... More
Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent

1771.64

5489958

3098.8

... More
Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent

229.1

709935

3098.8

... More
Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge:

152.95

398020

2602.29

... More
Supply and fixing 6 mm (1/4") thick China glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work.

-

-

-

... More
Ground & First Floor

385.69

388389

1007

... More
Second Floor

282.79

287617

1017.07

... More
Providing and laying "brick coba" 100 mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work.

2841.4

2024497

712.5

... More
Supply & fixing of flush doors commercial quality conforming to IS : 2202 Part I (1983) including fixing of wooden cleats & stoppers & including fixing & adjustment of hinges, bolts locks, handles, springs & other fittings but excluding their supply & including painting with two coats of black Japan paint on all iron fitting. Fitting with necessary screws to be supplied departmentally. 35 mm thick.

52.44

94654

1805

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

52.44

16441

313.53

... More
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I)

52.44

18083

344.85

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

294

34159

116.19

... More
Providing & fixing of door / windows grill. Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding

2552.14

155170

60.8

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Angle iron chaukhat (40x40x5)

357.9

39505

110.38

... More
Fixing of Door, windows / ventilators chaukhats in position.

-

-

-

... More
(a) Door chaukhats

51

5329

104.5

... More
(b) Window chaukhats

37

2987

80.75

... More
(c) Ventilator chaukhats

18

1026

57

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDMgasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5%tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window single panel with S.S. friction hinges (300x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension.(Area of window upto 0.75 sqm.)

15.36

125299

8157.51

... More
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).

89.8

703544

7834.57

... More
Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge.

143.55

54027

376.37

... More
Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles & rails will be mitred cut, joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer's specifications & direction of Engg.-in-charge. Non decorative finish

45.68

109203

2390.61

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections & other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia & size, including necessary filling up the gaps at junctions, i.e. at top, bottom & sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engg.-in-charge. (Glazing, paneling & dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron)

900.15

327852

364.22

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)

105.9

109646

1035.38

... More
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 2nd class teak wood beading 62X19 mm

105.16

115343

1096.84

... More
Polishing in high gloss/matt finish melamine clear polish on woodwork in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no.and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficientdrying time for 1st coat and 2nd coat is allowed to dry for 8 to 12hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finergrading with ample water to remove excess sealer layer andmake the surface further smooth after this wet rubbing, thensurface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)

241.78

229913

950.92

... More
Same as above but on new wood surface.

104.88

94745

903.37

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).

-

-

-

... More
Ground Floor

709.26

53903

76

... More
First Floor

777.24

59070

76

... More
Second Floor

847.2

65031

76.76

... More
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats. (For Internal wall surface & ceiling) (Asian Paint or equivalent)

-

-

-

... More
Ground Floor

6223.06

644771

103.61

... More
First Floor

3262.6

338037

103.61

... More
Second Floor

2153.86

223161

103.61

... More
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

-

-

-

... More
Ground Floor

6932.32

757355

109.25

... More
First Floor

4039.84

441352

109.25

... More
Second Floor

3001.06

331136

110.34

... More
Providing & fixing stainless steel sliding door bolts ISI marked to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm

51

24225

475

... More
P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc.

-

-

-

... More
(a) 250 mm x 10mm

51

16957

332.5

... More
(b) 200 mm x 10mm

51

12112

237.5

... More
Providing & fixing stainless steel handles ISI marked to required colour or shade with necessary screws etc. complete. 125 mm

102

19380

190

... More
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

56

4794

85.61

... More
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar

5

2200

440.15

... More
Providing & fixing of Rolling shutters of approved design made of 80 x 125 mm (3" x 18 gauge) cold rolled MS lath interlocked throughout their entire length and jointed together at the end by end locks end mounted on specially designed pipe shaft with brackets, side guides & arrangements for inside and outside poking with push & pull operation complete but excluding the cost of top cover and spring.

46.56

106156

2280

... More
Providing & fixing 27.5cm long wire spring grade No. 2 for rolling shutters.

8

6080

760

... More
Providing & fixing top cover for rolling shutters. 18 gauge.

21.8

11390

522.5

... More
Providing and fixing ball bearing for rollong shutters.

16

7600

475

... More
Providing & laying of light cinder filling under floor of toilets & other sunken roofs.

31.94

37928

1187.5

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

103.6

42429

409.55

... More
Construction of drain along with apron.

301

157994

524.9

... More
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). for ACP & STRUCTURAL GLAZING WORK

1109.55

321048

289.35

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

170.7

414841

2430.24

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

170.7

449403

2632.71

... More
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.

51.21

132360

2584.67

... More
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately):

860.16

1147573

1334.14

... More
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.

8.06

611165

75826.93

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes

3575

471792

131.97

... More
Supplying and installation of Extruded Aluminium linear facade and curves not exceeding 3000mm radius with 150X50mm block and 100mm space along with top and bottom cover and capping for individual profiles, fixed on extruded aluminum rail 80mmX50mm powder coated with dulux Eelctro black ace (or any specified shade) spanning between supports of maximum distance of 1500mm with the help of Sainless steel Non slip barb, steel rivet- galvanised to class 3, aluminium clip coated with external grade Matt powder coating, including the cost of necessary fittings and fixtures etc. as per approved drawing and design from Architect in charge (make Citadel/ Woodform Architectural or equivalent)

240.69

800294

3325

... More
Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone

565.32

5486385

9704.92

... More
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.

130

835693

6428.41

... More
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) Red sand stone - Exposed face machine cut and table rubbed with rough backing. 70 mm thick

237.95

910144

3824.94

... More
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.

285.53

141462

495.44

... More
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type. Fastener with threaded dia 10 mm

59.49

1570

26.4

... More
Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge.

87.4

2085879

23865.9

... More
Centering and shuttering including strutting, propping etc. and removal of form for

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

852.84

205142

240.54

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

4380.65

2751880

628.19

... More
SUB HEAD-I-SANITARY INSTALLATIONS

-

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid

21

92240

4392.41

... More
Providing & fixing toilet paper holder C.P. brass

21

11334

539.72

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

21

4910

233.82

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap

31

47032

1517.17

... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer

2

3235

1617.94

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

33

22843

692.24

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

33

5276

159.89

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

33

2493

75.57

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

33

36373

1102.24

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink) 15 mm nominal bore

82

32047

390.82

... More
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore

61

4059

66.55

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter

10

130

13.08

... More
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia

2

9559

4779.61

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore

8

3716

464.55

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

10

4689

468.93

... More
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040 mm bowl depth 200 mm

2

9950

4975.45

... More
Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete Flexible Pipe 32mm Dia

2

163

81.51

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore

21

7122

339.15

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore

5

2766

553.33

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.

19

105506

5552.95

... More
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade

7.84

22020

2808.69

... More
Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr) including all its accessories, complete in all respect including testing etc.

1

45267

45267.5

... More
Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc.

1

32803

32803.5

... More
Providing and fixing of storage type (pressurised type) electric hot water heater copper sheet container, 25 mm thick insulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. Capacity 25 Liters

2

28671

14335.5

... More
SUB HEAD-II-WATER SUPPLY

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
For Internal Toilet

-

-

-

... More
15 mm nominal outer dia Pipes

46.28

16185

349.73

... More
20 mm nominal outer dia Pipes

155.75

63433

407.28

... More
25 mm nominal outer dia Pipes

46.25

22954

496.32

... More
32 mm nominal outer dia Pipes

31.25

17657

565.05

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Internal work - Exposed on wall

-

-

-

... More
20 mm nominal bore

64.88

16475

253.94

... More
25 mm nominal bore

35.25

11248

319.12

... More
32 mm nominal bore

70.5

27585

391.29

... More
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall

-

-

-

... More
Terrace loop & Tank Filling Pipe

-

-

-

... More
50 mm nominal bore

81.25

56685

697.67

... More
65 mm nominal bore (i/c two coat of synthetic enamel paint)

87.5

73540

840.46

... More
Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:-

-

-

-

... More
Lehry Make Automatic OHT Level Control System Consist of Following Items 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch. 50mm

1

52259

52259.5

... More
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 50mm diameter pipe

81.25

2732

33.63

... More
Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral or equivalent approved complete in all respect as directed by Engineer-in-charge.

-

-

-

... More
15mm dia (9 mm thickness)

21

1496

71.25

... More
20mm dia (9 mm thickness)

10

712

71.25

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore

4

4729

1182.33

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
For vertical pipe connection with terrace ringmain

-

-

-

... More
20 mm nominal bore

4

1442

360.67

... More
25mm nominal bore

2

831

415.82

... More
32mm nominal bore

4

1843

460.77

... More
50mm nominal bore

3

2058

686

... More
65mm nominal bore

1

1164

1164.37

... More
Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks.

-

-

-

... More
25mm dia.

6

7096

1182.75

... More
50mm dia.

5

7362

1472.5

... More
65mm dia.

2

3230

1615

... More
150mm dia.

3

10188

3396.25

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water)

333.5

83294

249.76

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Single Push Fit Coupler

-

-

-

... More
110 mm dia

86.67

7487

86.39

... More
Single tee with door

-

-

-

... More
110x110x110 mm

10

1604

160.47

... More
Plain bend 87.5 deg

-

-

-

... More
110 mm dia

20

2062

103.1

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia

133.4

32732

245.37

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

14

2959

211.36

... More
SUB HEAD : IV - INTERNAL DRAINAGE

-

-

-

... More
Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.

-

-

-

... More
Internal Toilet (Soil & Waste Pipe)

-

-

-

... More
75 mm

156.25

83125

532

... More
110 mm

122.63

93781

764.75

... More
Exposed on Wall (Soil & Waste Pipe)

-

-

-

... More
110 mm

386.4

295499

764.75

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.

-

-

-

... More
Bend without door (87.5°)

-

-

-

... More
110mm bend

29

8265

285

... More
Bend without door (45°)

-

-

-

... More
100mm

21

4738

225.63

... More
75mm

49

6982

142.5

... More
Y' Fitting without door

-

-

-

... More
100mm

21

9576

456

... More
75mm

49

12335

251.75

... More
Reduced 'Y' Fitting without door

-

-

-

... More
100mm x 75mm

6

2194

365.75

... More
Single Tee without door

-

-

-

... More
110mm

21

8478

403.75

... More
75 mm

49

11870

242.25

... More
Single Tee with door

-

-

-

... More
110mm

9

4189

465.5

... More
Reduced Tee with door

-

-

-

... More
110mm x 75mm

11

4493

408.5

... More
Coupler

-

-

-

... More
110mm

96

22800

237.5

... More
Clean Out Plug (COP)

-

-

-

... More
110mm

13

2778

213.75

... More
75 mm

13

1914

147.25

... More
Vent Cowl

-

-

-

... More
110mm

16

1520

95

... More
Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.

-

-

-

... More
For Wash basin & Urinal

-

-

-

... More
50mm dia. Pipe

40.13

14296

356.25

... More
32mm dia. Pipe

72.88

13154

180.5

... More
Elbow (90°)

-

-

-

... More
50mm

19

1624

85.5

... More
32mm

33

1254

38

... More
Elbow (45°)

-

-

-

... More
50mm

6

427

71.25

... More
32mm

11

470

42.75

... More
T fitting

-

-

-

... More
50mm

19

1985

104.5

... More
32mm

33

1567

47.5

... More
Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge. 110mm x 75mm x 50mm/40mm (Toilet)

17

18411

1083

... More
Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.

-

-

-

... More
110mm x 75mm (Toilet)

30

30210

1007

... More
110mm x 75mm (Kitchen)

2

2014

1007

... More
Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony)

49

6494

132.55

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

7

13731

1961.65

... More
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter

14

4409

314.98

... More
Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.

80

26079

325.99

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100mm dia SW pipe

80

56794

709.93

... More
COST OF SEWERAGE WORKS

-

-

-

... More
"Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. "up to 1.50 m depth Pipes 80 mm to 300 mm diameter

115

37488

325.99

... More
Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter

172.5

9235

53.54

... More
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes

115

44955

390.92

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia.

115

62884

546.82

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line

9

83387

9265.24

... More
Extra for depth for manholes:

-

-

-

... More
Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5

4.5

28994

6443.24

... More
Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line

1

19348

19348.38

... More
Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5

0.5

3862

7725

... More
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

18

6950

386.16

... More
Supply, installing, testing and commissioning of non clog submersible type drainage / dewatering pumpset

-

-

-

... More
COST OF EXTERNAL WATER SUPPLY WORKS

-

-

-

... More
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work)

-

-

-

... More
65mm nominal bore.

22.5

13507

600.34

... More
50mm nominal bore.

75

38324

510.99

... More
32mm nominal bore.

56.25

20109

357.5

... More
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.

-

-

-

... More
65mm nominal bore.

1

1164

1164.37

... More
50mm nominal bore.

1

686

686

... More
32mm nominal bore.

1

460

460.77

... More
Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

27870

13935.32

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

8009

8009.01

... More
RAIN WATER HARVESTING

-

-

-

... More
RECHARGE PITS

-

-

-

... More
Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.

-

-

-

... More
In all kind of soil upto 1.5m depth

22.59

2575

114

... More
In all kind of soil upto 1.5m to 3.0m. depth

22.59

2897

128.25

... More
In all kind of soil upto 3.0m to 4.5m. depth

22.59

3219

142.5

... More
In all kind of soil upto 4.5 m to 6.0m. depth

10.54

1652

156.75

... More
Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.

1.2

6270

5225

... More
Class M-150 brick work in 1:4 cement coarse sand mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.

24.14

124984

5177.5

... More
Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.

1.61

11102

6896.05

... More
Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.

1.9

10108

5320

... More
12mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand)

46.16

6577

142.5

... More
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar

10

3657

365.75

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter

1

837

837.68

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually.

15

8092

539.5

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia

15

7989

532.63

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

12.13

12338

1017.21

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

13.11

13404

1022.45

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.

13.11

13404

1022.45

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

1

1155

1155.43

... More
DESILTING CHAMBER

-

-

-

... More
Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.

-

-

-

... More
In all kind of soil upto 1.5m depth

10.05

1088

108.3

... More
In all kind of soil upto 1.5m to 3.0m. depth

4.06

494

121.84

... More
Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.

1.04

5162

4963.75

... More
Class M-150 brick work in 1:4 cement coarse sand mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.

3.52

17313

4918.63

... More
Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.

1.38

9040

6551.25

... More
Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.

1.63

8238

5054

... More
15mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand)

17.6

2382

135.38

... More
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar

12

4169

347.46

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter

2

1591

795.8

... More
DRAINAGE NETWORK

-

-

-

... More
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mm diameter

115

37488

325.99

... More
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes

115

44955

390.92

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia.

115

62884

546.82

... More
Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as per design. With FPS bricks

10

58651

5865.12

... More
Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:

-

-

-

... More
Drain 300 wide average. Depth 45 cm with R.C.C. slab

176

323841

1840.01

... More
Drain 450 wide average. Depth 45 cm with R.C.C. slab

33

83288

2523.88

... More
SEPTIC TANK & SOAK PIT

-

-

-

... More
Size :- Length = 7.50 M. Width = 2.65M Total Depth =3.00M

-

-

-

... More
Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed.

-

-

-

... More
In all kind of soil upto 1.5m depth

47.38

5401

114

... More
In all kind of soil upto 1.5m to 3.0m. depth

45.09

5782

128.25

... More
In all kind of soil upto 3.0m to 4.5m. depth

12.02

1712

142.5

... More
Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size)

4.69

24505

5225

... More
Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand)

19.51

101013

5177.5

... More
Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.

3.98

27446

6896.05

... More
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.

3.12

165

53.2

... More
12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand)

82.6

11770

142.5

... More
Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.

12

4389

365.75

... More
Providing and fixing C.I. tee at the inlet and outlet of septic tank.

2

1191

595.65

... More
Providing & fixing 75mm dia vent pipes.

1

727

727.62

... More
Providing & fixing of 75mm dia cast iron terminal guard.

1

248

248.59

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.

-

-

-

... More
M.D. -10- Circular shape 500mm internal diameter

2

1675

837.68

... More
M.D. -2.5- Circular shape 450mm internal diameter

4

3322

830.67

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks

2

44441

22220.81

... More
CONSTRUCTION OF TUBE WELL (suitable for 1000 lpm yield)

-

-

-

... More
Transportation Charges of drilling equipment including assembly and other material as required.

1

9500

9500

... More
Drilling of 675 mm. dia by rotary machine

100

123500

1235

... More
Supply & laying of 350 mm. dia housing pipe (8 mm. thick)

40

87400

2185

... More
Supply & laying of 200 mm. dia blind pipe (8 mm. thick)

25

42750

1710

... More
Supply & laying of 200 mm. dia slotted pipe (8 mm. thick)

35

59850

1710

... More
Supply & fixing of 350 mm. dia Socket

8

10640

1330

... More
Supply & fixing of 200 mm. dia Socket

11

8360

760

... More
Supply & fixing of 200 mm. dia Bail plug

1

1140

1140

... More
Supply & fixing of 350 mm. dia well cap

1

1710

1710

... More
Supply & fixing of 350x200 mm. dia reducer.

1

3610

3610

... More
Supply & fixing of 350 mm. dia housing clamp

1

1900

1900

... More
Supply & Filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I.

32

69920

2185

... More
Development by air compressor including Transportation.

25

42750

1710

... More
Development by O.P. Unit including Transportation.

35

49875

1425

... More
Supply of submersible pump suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition. A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm. B - Total Head of pump set 45 m.

1

59850

59850

... More
Supply and fixing of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm.

55

9405

171

... More
Supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having L&T of qul. Male switch fuse unit with HRC fuses, Ameter, Boltmeter, Selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of Jyoti or eq. Air break Star- Delta motro starter suitable for above submersible pump set.

1

17100

17100

... More
Supply of 80mm dia M.S. column pipe of class 'C' both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements.

55

94050

1710

... More
Supply of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc.

2

2660

1330

... More
Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make.

1

6175

6175

... More
Supply of 80mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make.

2

15200

7600

... More
Supply of C.I. double flanged bend of 80mm dia i/c cost of material and labour.

1

1377

1377.5

... More
Supply of 80mm dia C.I. tee heavy quality i/c cost of material.

1

5700

5700

... More
Supply of Guru/Fibing or equivalent make pressure gauge.

1

4750

4750

... More
Erection & commissioning of pumping plants complete along with electric wiring.

1

14250

14250

... More
Supply of steel wire rope of 1/2" size

55

2612

47.5

... More
S/B of 600mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead on one no. 8 to 10 SWG GI wite in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. , pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of E/I complete in all respects as per drawing.

1

4085

4085

... More
S/F of one number 8 to 6 SWG G.I. wire in 15mm dia G.I. Pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. T&P other material required for proper completion of the work as directed at site.

8

1520

190

... More
S/F of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E/I complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm x 4 core

40

8360

209

... More
FIRE FIGHTING SYSTEM

-

-

-

... More
Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.

145

47268

325.99

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm nominal bore (pipe in pump room & external)

145

295182

2035.74

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way - 100 mm dia M.S. Pipe (Siamese & draw out connection)

1

5371

5371.79

... More
SUB HEAD-II: INTERNAL FIRE FIGHTING WORKS (HYDRANT SYSTEM)

-

-

-

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head

1

68683

68683.54

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump)

1

1231

1231.8

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (for terrace booster pump)

1

952

952.94

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia.

2

10624

5312.03

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia.

1

8801

8801.41

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
80 mm nominal bore

14.5

21777

1501.9

... More
100 mm nominal bore

94.25

191868

2035.74

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal

5

30460

6092.07

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m

5

48096

9619.35

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun metal

10

41447

4144.77

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal

5

9624

1924.99

... More
Providing and fixing standard fire mans axe with heavy duty insulated rubber handle.

5

7315

1463

... More
Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge. (Approx. size of door: 900mm Wide & 1500mm Height)

5

39862

7972.4

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

5

5262

1052.52

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

1

15301

15301.24

... More
SUB HEAD-III: FIRE EXTINGUSHER

-

-

-

... More
Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

5

56905

11381

... More
Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

5

43225

8645

... More
Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge.

16

15200

950

... More
SUB HEAD-IV: ELECTRICAL WORKS (For Terrace Pump)

-

-

-

... More
Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. 3CX6Sqmm AL XLPE Cable

100

26220

262.2

... More
Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 3CX6Sqmm AL XLPE Cable

2

165

82.65

... More
Fabricating & Supply, installing, testing and commissioning of sheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle. (As per the Technical Specifications) (At Terrace floor)

1

19000

19000

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width x 50mm depth x 1.6 mm thickness.

50

24062

481.24

... More
SCHEDULE OF QUANTITIES FOR ELECTRICAL WORKS

-

-

-

... More
SUBHEAD I- WIRING POINTS

-

-

-

... More
Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash

513

297283

579.5

... More
Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash.

91

58007

637.45

... More
Wiring point for 5Amp plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with14 SWG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash.

68

21124

310.65

... More
Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points.

-

-

-

... More
Addition for light / fan points with modular type switch in place of piono type switch.

588

24578

41.8

... More
Addition for plug points with modular type switch in place of piono type switch.

148

11669

78.85

... More
Addition for Exhaust fan points with modular type switch in place of piono type switch.

16

714

44.65

... More
Supply and fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.

80

25840

323

... More
Supply and fixing of power plug with 20A/250 V flush type switch and 5 Pin 20 A/250V flush type universal socket in suitable M.S. box including supply of all material, labor T&P etc. required for proper completion of work.

7

4156

593.75

... More
Supply & wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FR PVC insulated 1100 V grade single core multistrand copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C.

336

38623

114.95

... More
Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.

2850

403417

141.55

... More
Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.

255

49419

193.8

... More
Supply and wiring of submain 2 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 6 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.

585

151164

258.4

... More
Supply and wiring of submain 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 32mm dia PVC conduit partly concealed in wall and partly laid in slab along with two number 10 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.

788

372054

472.15

... More
Supply and wiring of 4 number 16 sq. mm. PVC insulated 1100 V grade single core Copper conductor cable in 40 mm dia PVC conduit concealed in wall, with two number 10 sqmm single core Copper conductor cable as earth continuity wire drawn in coudit including matching colour wash etc., cable as earth contunity wire etc. complete in all respects.

66

45771

693.5

... More
Supply fixing and concealing of 20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work( for Telephone)

924

54423

58.9

... More
SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS

-

-

-

... More
Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects.

75

9975

133

... More
Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.

16

2964

185.25

... More
Supply and fixing hexagonal/Round G.P. fan box of approved make made up of 1.0mm thick ISI Marked G.P. sheet spot weeldeed Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screewed fitted with 300mm round zink coted M.S Bar X 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.

75

10687

142.5

... More
Supply of Ceiling Fan with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system.BEE 5 Star rated-1200mm sweep

75

128250

1710

... More
Supply fixing of electronic fan regulator(Modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.

75

36836

491.15

... More
Supply and fixing of recess/surface mounting round 24 to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA

12

41610

3467.5

... More
Supply and fixing of 1'X1' recess/surface mounting 18 Watt to 20 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. CAT- AAA

119

395675

3325

... More
Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 2 x 22 watt suitable for up to 2 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA)

87

147943

1700.5

... More
Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 1 x 22 watt suitable for up to 1 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA)

105

118702

1130.5

... More
Supply & fixing of recess/Surface mounting round 6 to 8 watt, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respect.(CAT: AAA)

61

44621

731.5

... More
Supply and fixing of water tight oblong 10 watt LED bulhead luminaire with driverr set confirming to IP 65 and above Protection complete in all respect.(CAT: AAA)

15

19950

1330

... More
Supply and fixing of batten/angle holder complete all respect.

10

570

57

... More
Supply and fixing of 3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect. CAT-AAA

16

27512

1719.5

... More
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. CAT-AAA

8

34580

4322.5

... More
NON SCH.

-

-

-

... More
Supply and fixing of 17 watt LED Mirror Light and complete in all respect.

27

31703

1174.2

... More
Supply and fixing of 12 watt LED bulb complete in all respect.

10

2460

246.05

... More
Supply and fixing of 40 watt Tungsten Filament Antique Glass Light Incandescent Bulbs Vintage Base E27 Bulb Yellow Light. complete in all respect.

53

9667

182.4

... More
Supply and fixing of Dome Shape Pendent Light, complete in all respect, Make : Havells, Wipro, Philips ,Jaguar, Bajaj or Eq.

53

124364

2346.5

... More
SUBHEAD III-DISTIBUTION BOARD

-

-

-

... More
Supply and fixing of surface/flush mounting distribution boards with additional metal door without MCB complete in all respects.(CAT A)

-

-

-

... More
8 Way SPN

2

3610

1805

... More
12 Way SPN

8

17100

2137.5

... More
6 Way TPN

11

45666

4151.5

... More
8 Way TPN

4

19798

4949.5

... More
4 Way VTPN

6

48792

8132

... More
Supply and fixing of 6Amp to 32 Amp (10 KA)SP MCB in existing MCB, DB complete with connections as required. (CAT: A)

163

40261

247

... More
Supply fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A)

-

-

-

... More
6 Amp. to 32 Amp. DP MCB (10 KA) C Curve (CAT: A)

10

7030

703

... More
40 Amp. TP MCB (CAT: A)

12

20292

1691

... More
40 Amp. FP MCB (CAT: A)

14

30257

2161.25

... More
63 Amp. FP MCB (CAT: A)

1

2175

2175.5

... More
S&F and making connection of 25A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge.

42

90573

2156.5

... More
S&F and making connection of 40A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge.

3

6498

2166

... More
Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. (CAT: A)

121

2873

23.75

... More
Non-Sch.

-

-

-

... More
Supply fixing and making connection of following MCCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 63 Amp. FP MCCB (25 KA) Thermal Magnetic release

6

43263

7210.5

... More
SUBHEAD IV-CABLES

-

-

-

... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc

-

-

-

... More
300 sq. mm 3.5 core

400

612940

1532.35

... More
185 sqmm 3.5 core

300

324900

1083

... More
35 sqmm 3.5 core

30

12027

400.9

... More
25 sqmm 3.5 core

400

141740

354.35

... More
6 sqmm 3 core

200

53960

269.8

... More
Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of EngineerIncharge

-

-

-

... More
300 sqmm 3.5 core

2

959

479.75

... More
185 sqmm 3.5 core

2

754

377.15

... More
35 sqmm 3.5 core

2

338

169.1

... More
25 sqmm 3.5 core

18

2103

116.85

... More
6 sqmm 3 core

2

144

72.2

... More
Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.

-

-

-

... More
300 sqmm

6

2234

372.4

... More
185 sqmm

6

1100

183.35

... More
150 sqmm

2

277

138.7

... More
95 sqmm

2

167

83.6

... More
35 sqmm

6

176

29.45

... More
25 sqmm

56

1436

25.65

... More
16 sqmm

18

359

19.95

... More
6 sqmm

6

102

17.1

... More
SUBHEAD V-EARTHING

-

-

-

... More
Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.

7

35777

5111

... More
Supply and burying of 600mm X 600mm X 3 mm copper Plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I pipe and funnel for watering and one earthing lead of one no. 8 SWG copper wire in 15 mm dia G.I pipe up to switch board ( from appron to switch board the cost of G.I pipe and copper wire will be extra) 30 cm square C.I frame with hinged cover masonry housing alternate layers of charcoal / coke and salt atleast 150mm thick alround etc. as per directions of Engineer in charge complete in all respects.

2

19855

9927.5

... More
Supply and laying of 32mm x 6mm G.I. strip from earth electrode directly in the ground as required complete in all respects.

168

23940

142.5

... More
Supply and Laying of 32mm X 6 mm Copper strip from earth electrode directly in the ground as required complete in all respects..

84

88578

1054.5

... More
Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects.

126

10773

85.5

... More
Supply & fixing of two number 8 SWG G.I. wire in 15mm dia GI pipe for earthing purpose as required complete in all respects.

50

9975

199.5

... More
L.T. PANEL

-

-

-

... More
Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.

-

-

-

... More
The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm BUILDING MAIN LT PANEL Incoming : 1 No 250 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity 1 No 200 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity 1 No 125 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity 1 No 63 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity 1 No 200 Amp. 4P ATS Metering : 1 Set of CT's one of 250/ 5Amp ratio for Multifunction Meter 1 Set of CT's one of 200/ 5Amp ratio for Multifunction Meter 1 Set of CT's one of 125/ 5Amp ratio for Multifunction Meter 1 Set of CT's one of 63/ 5Amp ratio for Multifunction Meter 4 Set of Phase Indication Lamp. Bus Bar : One (1) No. 300 Amp. FP aluminimum bus bar of suitable length. One (1) No. 160 Amp. FP aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 100 Amps FP MCCB of 25KA - 2 No 63 Amps FP MCCB of 25KA - 10 No 40 Amps FP MCCB of 25KA - 1 No 32 Amps DP MCB of 10KA - 2 No SPARE & SPACE Panel described as above

2

850677

425338.75

... More
METERING PANEL Incoming : 1 No 100 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity Metering : 1 Set of CT's one of 100/ 5Amp ratio for Multifunction Meter 1 Set of Phase Indication Lamp. Bus Bar : One (1) No. 120 Amp. FP aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 63 Amps FP MCB of 10KA - 2 No 32 Amps DP MCB of 10KA - 9 No Single Phase Energy Meter- 8 Nos. Three Phase Energy Meter- 1 Nos. SPARE & SPACE Panel described as above

2

251913

125956.7

... More
SUBHEAD VII-TELEPHONE SYSTEM

-

-

-

... More
S/F MODULAR BOXES, BASE & COVER PLATE :-

-

-

-

... More
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75 mm)

10

2374

237.43

... More
S/F MODULAR TYPE SWITCH / SOCKET :-

-

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.

-

-

-

... More
Telephone socket outlet

8

943

117.92

... More
TV Antenna socket outlet

2

189

94.82

... More
Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair

192

5813

30.28

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required.

48

764

15.93

... More
Supplying and fixing modular blanking plate on the existing modular plate& switch box excluding modular plate as required

5

159

31.87

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable

288

11246

39.05

... More
NON SCH.

-

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. RJ-45 Jack With Cat 6 -2M

12

5928

494

... More
Supplying telephone wire following pair 0.6 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 5 Pair

100

7695

76.95

... More
S/f of 10 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same

1

2853

2853.8

... More
SUBHEAD VIII-CABLES TRAY & RACEWAY

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

30

15991

533.04

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

20

11409

570.49

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

4

3693

923.45

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

2

2023

1011.89

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

2

2114

1057.3

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

2

2627

1313.85

... More
Providing, Laying and Fixing following Dia RCC Pipe NP 2 Class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 ( 1 Cement : 2 fine sand)including trenching ( 75 cm) deep and refilling etc. as required. 150mm dia

10

5768

576.86

... More
NON SCH.

-

-

-

... More
Providing and Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cutting and making good the walls & floors as per requirement. 150mm

10

6175

617.5

... More
Supply of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required

-

-

-

... More
300mm sweep.

16

33592

2099.5

... More
600mm sweep.

2

15198

7599.05

... More
Supply of AC 230/250 Volts, 50 Hz Wall fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep.

12

25764

2147

... More
Making of following size of Cable Chamber made of 230 mm thick brick work in cement mortar (1 cement : 6 sand) with PCC 100 mm thick PCC base plastering of inner and outer surface with cement mortar including providing of Heavy Duty C.I Cover complete with digging, refilling and removal of surplus soil complete as required. 900 mm x 900 mm x 1000 mm deep

2

12847

6423.9

... More
(NON SCH)

-

-

-

... More
Supplying, Installation and commissioning of AMF start silent type 50 KVA DG set comprising of suitable BHP diesel engine directly coupled to 3 phase Model- 4K1080TAG2 Engine BHP-80 rated at 1500 RPM, Water Cooled, Four Stroke Electric Start 4 Cylinders Diesel Engine conforming to BS 5514 with capacity Of 10%, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank of 990 ltrs. capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB norms Complete with axial flow heavy duty exhaust fans for adequate ventilation exhaust of hot air etc including making of cement concrete foundation of 1: 2:4 (1 cement 2 sand and 4, 40mm graded stone aggregate) as per manufacturer recommendation complete as per specifications and conditions as required. (The diesel engine and alternator shall be so rated to deliver the specified output at site condition complete with control cable etc. as required.

1

427500

427500

... More
SUBHEAD XI- Solar Photovoltaic Power Plant

-

-

-

... More
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystal line silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium /GI structure of suitable strength with following components complete as required:- a)Solar Photovoltaic Module of capacity 330Wp or above,manufactured in India, conforming to IS 14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV module sused in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350- 800 V DC Input voltage range and 400V AC, three phase, 4 wire,50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. as required.

20

1160140

58007

... More
ESTIMATE OF FOR 4.5 Mt. WIDE C.C. ROAD

-

-

-

... More
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge etc( PWD-251)

69.97

7976

114

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metr etc(DSR 16.1)*0.8222

466.45

65764

140.99

... More
Supplying and stacking at site. 16.3.1 90 mm to 45 mm size stone aggregate etc and Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .(DSR 16.3.2 and 16.4)*0.8222

69.97

88783

1268.88

... More
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,etc(DSR 16.43.2)*0.8345

69.97

546892

7816.1

... More
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners,etc(DSR 16.45)*0.8222

419.81

1620

3.86

... More
Providing and laying in position bitumen hot sealing compound for expansion joints etc. (DSR- 16.46.1*0.8222) Using grade 'A' sealing compound.

419.81

2590

6.17

... More
TREMIX FLOORING IN PARKING AREA

-

-

-

... More
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge etc( dsr 2.1)

38.81

4424

114

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metr etc dsr 16.1

258.57

36455

140.99

... More
Supplying and stacking at site. 16.3.1 90 mm to 45 mm size stone aggregate etc and Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .(dsr16.3.2 and 16.4)

38.81

49245

1268.88

... More
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,etc(sor 16.43.2)

38.81

303342

7816.1

... More
Providing and laying in position bitumen hot sealing compound for expansion joints etc. (DSR- 16.46.1*0.8681) Using grade 'A' sealing compound.

162

949

5.86

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

4.05

27655

6828.61

... More
[ LANDSCAPING WORK ]

-

-

-

... More
Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment).

333.94

88337

264.53

... More
Carrigae of sludge upto 5 K.M.

333.94

56349

168.74

... More
Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm

55.66

16020

287.83

... More
Carrigae of manure upto 5 K.M.

55.66

8922

160.3

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.

389.59

12813

32.89

... More
Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately).

389.59

18349

47.1

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately).

-

-

-

... More
Holes 0.9 m dia. and 0.90 m deep.

20

2575

128.75

... More
Providing & stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge.

25

14621

584.84

... More
Providing & stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35cm as per direction of the officer-in-charge.

20

9897

494.87

... More
Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf.

328.92

5236

15.92

... More
Sand Stone Pathway

-

-

-

... More
Supplying & Laying of P.C.C. in 1:4:8 (1 Cement :4 Coarse sand : 8 stone aggregate 40 mm nominal size in base includinmg supply of all material labour T&P etc.

23.16

97272

4200

... More
40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Red sand stone

180.14

194221

1078.17

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

9.01

64763

7188.01

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

36.03

9832

272.9

... More
[ COBBLE PATHWAY ]

-

-

-

... More
Earth work in excavation

-

-

-

... More
Excavation by Manual means

130.35

15642

120

... More
Surface dressing

1738

34794

20.02

... More
P.C.C. 1:4:8

130.35

547470

4200

... More
B/W in 1:4 ( 1Cement :4 Coarse sand)

29.98

166389

5550

... More
12 mm plaster in 1:3 outer

260.7

39105

150

... More
12 mm plaster in 1:3 inner

199.87

29980

150

... More
Providing & fixing Cobble Stone Flooring (10X10X10)cm filling of joints in 1:3 Cement mortar with matching colour pigments all complete specification & direction of Engineer in charge.

1738

3284820

1890

... More
[ ABSTRACT OF COST - CHHATRI ]

-

-

-

... More
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles

60

120017

2000.29

... More
Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.

12.75

1453

114

... More
Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand.

2.65

2517

950

... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors.

4.03

16079

3990

... More
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)

25.6

3769

147.25

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20.

0.61

4091

6706.79

... More
As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete).

3.53

24345

6896.79

... More
As in item 6 but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete).

1.78

12614

7086.79

... More
As in item 6 above but in R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete).

3.88

24547

6326.79

... More
As in item 6 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20.

2.6

18278

7030

... More
M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.

6.89

34363

4987.5

... More
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.

18.59

98898

5320

... More
15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand)

5.3

1489

281.04

... More
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing. 30 mm thick

75.77

254081

3353.32

... More
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.

90.92

45045

495.44

... More
Supplying, fabricating, transporting, hoisting and fixing in position good quality of 70 mm Red sandstone in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects.

15.15

158395

10455.16

... More
Supply/FIXING OF Installation Of Fountain

1

581400

581400

... More
[ ABSTRACT OF COST - POND (SIZE - 30.0X 3.3 MT. ]

-

-

-

... More
Earth work in exacavation in trenches for foundations in ordinary soil (loan clay or sand) including lift upto 1.5m and leadup to 30m.&including filling watering & ramming of excavated earth in to trenches or into the space between the building & the sides of foundation trenches or in to the plinth and removal & disposal of surplus excavated earth as directed by the Engineer i/c upto a distance of 30 m from the foundation trenches.

100.22

11425

114

... More
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form-work,in foundation and floors.

6.36

25376

3990

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size) (Footing)

19.09

120778

6326.79

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

15.12

106293

7030

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

41.69

221790

5320

... More
Water proofing of pool as per spec.of DON building Chemicals.

144.39

192038

1330

... More
Providing & fixing Glass Mosaic tiles in pond.

144.39

493813

3420

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab all colour and texture except black, Cherry/ Ruby red Area of slab over 0.50 sqm

41.09

107545

2617.31

... More
Centering and shuttering including strutting, propping etc. and removal of form for.

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

19.44

4676

240.54

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

220.5

138515

628.19

... More
Underground Sump

-

-

-

... More
Supply installing , testing and commissioning of non clog submerssible tupe drainage/dewatering pumpset. Product Type: SUBMERSIBLE DRAINAGE PUMP Product Configuration Pump Classification: Standard Pump Component Materials Volute Material: Cast Iron FG 260 Impeller Material: Cast Iron FG 260 Shaft Material: S.S AISI 410 Seal Material: Carbon/Ceramic/NBR/S.S 304 Motor Specifications Phase: 3 Voltage: 380-415V Cable Length: Standard - 5 metres Cable Length: Additional - 0 metres: 0 Pipework Connection Float Switch: With Float Switch Solids Diameter Limit Maximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9m Each Pump Set Detail = 1W+1S ( 2No. for LOWER GROUND TOILET)

2

111180

55590

... More
Filling of carted earth. (230.13*4)

920.52

238654

259.26

... More
COST OF LIFT 13 PERSON

1

1283300

1283300

... More
COST OF SOLAR PHOTO VOLTAIC PLANT

1

1004500

1004500

... More
COST OF D.G.SET - 50 KVA

1

461660

461660

... More
GST Extra as per applicable

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.