Uttar Pradesh Projects Corporation Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Projects Corporation Limited - UPPCL Tender

Works
Eprocure
Opening Date15 May 2021
Closing Date25 May 2021
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation

20.07

-

4655

... More
Same as above but for under floor

20.71

-

4655

... More
R.C.C. work with cement approved coarse sand and 2 cm. (3/4") gauge approved stone ballast in the proportion of 1:1.5:3 (M-20) in raft foundation and footing excluding supply of reinforcement and its binding but B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item

0.71

-

7028.22

... More
R.C.C. work with cement approved coarse sand and 2 cm. (3/4") gauge approved stone ballast in the proportion of 1:1.5:3 (M-20) in columns excluding supply of reinforcement and its binding but B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item

0.27

-

7410

... More
R.C.C. work with cement approved coarse sand and 2 cm. (3/4") gauge approved stone ballast in the proportion of 1:1.5:3 (M-20) in lintels of doors and windows excluding supply of reinforcement and its binding but B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item

5.12

-

6933.22

... More
First Class brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, and T & P etc.required for proper completion of the work. 4300+(4700-4400)

144.44

-

4370

... More
15 mm cement plaster on plinth side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)

45.82

-

252.86

... More
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqmfloor only shall be measured as per I.S.6313(PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm.

217.08

-

95

... More
Filling of carted earth

280.98

-

292.6

... More
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).

29.27

-

275.81

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

29.27

-

87.21

... More
SUPER STRUCTURE Class-150 brick work in 1:6 cement and coarse sand of 2.25 coarseness modulus mortar in super-structure. Above plinth level up to floor two level (up to two storey) including necessary cutting and molding of brick work as required and also including honey combed brick work in thickness of wall more than 12cms. (a) Ground Floor

77.65

-

4627.45

... More
( b) First Floor

77.26

-

4627.45

... More
Class-150 brick work in 1:4 cement and coarse sand of 2.25 coarseness modulus mortar in super-structure. Above plinth level up to floor two level (up to two storey) including necessary cutting and molding of brick work as required and also including honey combed brick work in thickness of wall 12cms. (a) Ground Floor

5.75

-

4841.2

... More
(b) First Floor

38.04

-

4841.2

... More
6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. (a) Ground Floor

30.26

-

239.14

... More
(b) First Floor

30.23

-

239.14

... More
R.C.C. work with cement approved coarse sand and 2 cm. (3/4") gauge approved stone ballast in the proportion of 1:1.5:3 (M-20) in lintels of doors and windows excluding supply of reinforcement and its binding but B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item (a) Ground Floor

4.54

-

6933.22

... More
(b) First Floor

4.53

-

7002.55

... More
R.C.C. work with cement approved coarse sand and 2 cm. (3/4") gauge approved stone ballast in the proportion of 1:1.5:3 (M-20) in columns excluding supply of reinforcement and its binding but B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item (a) Ground Floor

0.32

-

7410

... More
(b) First Floor

0.32

-

7484.1

... More
R.C.C. work with cement approved coarse sand and 2 cm. (3/4") gauge approved stone ballast in the proportion of 1:1.5:3 (M-20) in beams excluding supply of reinforcement and its binding but B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item (a) Ground Floor

3.67

-

7075.72

... More
(b) First Floor

4.19

-

7146.48

... More
R.C.C. work with cement approved coarse sand and 2 cm. (3/4") gauge approved stone ballast in the proportion of 1:1.5:3 (M-20) in slab excluding supply of reinforcement and its binding but B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item (a) Ground Floor

36.41

-

6507.5

... More
(b) First Floor

37.28

-

6572.58

... More
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage & over lapping & hooks. (a) Plinth Lvl-

7.22

-

5225

... More
(b) Ground Floor

40.44

-

5225

... More
(c) First Floor

41.93

-

5225

... More
Using M.S. Angles 40x40x6mm for diagonal braces. (a) Ground Floor

199.35

-

54.15

... More
(b) First Floor

156

-

54.15

... More
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fasts, tie, rods, grating etc. ( when not included in an over all rates ) wrought to required form, including supply of steel bolts,nuts and wastage etc and their fixing required for proper completion of the work. M.S work in hold fast Door/Window/Ventilator (a) Ground Floor

72

-

54.15

... More
(b) First Floor

67.2

-

54.15

... More
Fabrication of Z section fixed / Open able steel windows including necessary steel fitting such as handles stay etc. (a) Ground Floor

675

-

54.15

... More
(b) First Floor

921.38

-

54.15

... More
Fabrication of window/Fixed Grill. (a) Ground Floor

540

-

54.15

... More
(b) First Floor

737.1

-

54.15

... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading (a) Ground Floor

27

-

610.23

... More
(b) First Floor

36.86

-

610.23

... More
Fixing of Door, windows / ventilators chaukhats in position. i-Ground Floor (a) Door chaukhats

13

-

142.5

... More
(b) Window chaukhats

8

-

95

... More
(c) Ventilator chaukhats

5

-

57

... More
ii-First Floor (a) Door chaukhats

10

-

142.5

... More
(b) Window chaukhats

11

-

95

... More
(c) Ventilator chaukhats

4

-

57

... More
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) (2.25FM) (a) Ground Floor

567.8

-

240.92

... More
(b) First Floor

499.26

-

240.92

... More
12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth. (1) 1:6 (1 cement: 6 coarse sand) (2.25FM) (a) Ground Floor

279.95

-

208.94

... More
(b) First Floor

427.85

-

208.94

... More
Engraving lines in the plaster of outer face wall vertically and horizontally to display the surface as stone facing as directed by the Engineer-in-charge including labour & T& P etc. required for proper completion of the work. Add for extra labour to all items of plaster. (a) Ground Floor

639.9

-

26.6

... More
(b) First Floor

559

-

26.6

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

174.8

-

46.69

... More
Sand filling in plinth excluding supply of necessary quantity of sand from a distance not excceding 8 km. (5 miles) from the site of work and including watering, ramming,dressing etc. rate to include cost of all materials, labour and T & P etc. required for proper completion of the work (Labour only). (a) Ground Floor

29.05

-

688.75

... More
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).

64.69

-

228

... More
Providing and laying of 8 to 10 mm thick ivory or light shade Vitrified tiles of 600 mm X 600 mm size in flooring or skirting laid with 1:3 cement mortar (1 cement : 3 coarse sand) finishing with cement slurry & with pigment grouting & polishing complete i/c supply of all materials, labour T & P required for proper completion of work. (a) Ground Floor

107.64

-

1330

... More
(b) First Floor

74.76

-

1330

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by anufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.11.46.2 Size of Tile 600x600 mm (a) Ground Floor

15.3

-

1330

... More
(b) First Floor

5.54

-

1330

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick (a) Ground Floor

78.26

-

1214.41

... More
(b) First Floor

102.62

-

1214.41

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (a) Ground Floor

26.05

-

1434.96

... More
(b) First Floor

31.45

-

1434.96

... More
Supply and fixing 6 mm (1/4")thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. (a) Ground Floor

19.45

-

1140

... More
(b) First Floor

13.69

-

1140

... More
Supply and fixing 6 mm (1/4")thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. (a) Ground Floor

84.24

-

1140

... More
(b) First Floor

67.52

-

1140

... More
Providing and fixing of flush door shutters commercial quality conforming to IS : 2202 Part I (1983) including fixing fixing of wooden cleats & stoppers and including fixing and adjustment of hinges, bolts locks, handles, springs and other fittings but excluding their supply and including painting with two coats of black Japan paint on all iron fitting if necessary. Fitting with necessary screws to be supplied departmentally. (a) Ground Floor i-35 mm thick.

24.89

-

1520

... More
First Floor i-35 mm thick.

15.33

-

1520

... More
ii-For Double Leaf

5.67

-

1600.75

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.10.5.1 Using M.S. angles 40x40x6 mm for diagonal braces

1.89

-

3458.78

... More
Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm (a) Ground Floor

13

-

351.5

... More
(b) First Floor

10

-

351.5

... More
P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 300 mm x 10mm (a) Ground Floor

13

-

256.5

... More
(b) First Floor

10

-

256.5

... More
Providing & fixing stainless steel handles ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 125 mm (a) Ground Floor

26

-

190

... More
(b) First Floor

20

-

190

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water tinnable priming coat with cement primer (50+23)=73 (a) Ground Floor

782.03

-

69.35

... More
(b) First Floor

722.27

-

69.35

... More
Finishing walls with two coat of acrylic Smooth exterior paint of best quality Including supply of all material labour and T&P etc. required for proper completion of the work. (a) Ground Floor

279.95

-

103.55

... More
(b) First Floor

427.85

-

103.55

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (a) Ground Floor

1061.98

-

102.6

... More
(b) First Floor

1150.12

-

102.6

... More
Providing & fixing panes of glass with equal or equivalent I.S.I marked quality putty. Brads and springs and including supply of all materials and labour etc complete . 3.8 to 4.7 mm thick (a) Ground Floor

27

-

399

... More
(b) First Floor

36.86

-

399

... More
Painting or vanishing two coats on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T & P etc. required for proper completion of work.Paint to be used should confirm to the I.S.I No.103 1950 (59+27)=86 (a) Ground Floor

156.6

-

81.7

... More
(b) First Floor

128.84

-

81.7

... More
Painting or vanishing two coats on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T & P etc. required for proper completion of work.Paint to be used should confirm to the I.S.I No.103 1950 (59+27)=86 (a) Ground Floor

49.77

-

81.7

... More
(b) First Floor

42

-

81.7

... More
Providing & laying "brick Coba" 12mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work.

230.17

-

1108.7

... More
Construction of drain along with apron.

71.88

-

397.41

... More
Providing & laying of light cinder filling under floor of toilets & other sunken roofs.

6.16

-

1503.66

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

29.91

-

369.12

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (a) Ground Floor

14.96

-

3610

... More
(b) First Floor

7.64

-

3610

... More
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).

8.76

-

968.49

... More
Providing and fixing in position collepsible steel shutters with verticals chanels 20*10*2mm & braced with flate iron digonals 20*5mm.size with top & bottom rails of T iron 40*40*6mm.with 38m dia steel pulleys with bolts. Nut locking arregement stopers handle complete including applying a priming coat of approved lead point.

10.11

-

3676.5

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter

48.15

-

238.27

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm bend

14

-

101.42

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

14

-

225.58

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

7

-

190.63

... More
INTERNAL SAINATRY AND WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with ISI marked white solid plastic seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. (5260.95*0.8345)

4

-

4170.75

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fitting and fixtures completed including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests

2

-

4298.03

... More
Providing & fixing white viterous china wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fitting and brackets, cutting & making good the walls wherever required .Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap (2510.45*0.8345)

6

-

1990.22

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. (a) 32 mm dia (for wash basin)

6

-

80.15

... More
Providing & Fixing 600 X 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

6

-

1017.17

... More
Providing & fixing viterous china toilet paper holder.

4

-

337.84

... More
Providing & fixing white vitreous china flat back half stall Urinal of 580x380x350 mm with white PVC automatic flushing cistern with fittings standard size CP brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in CP brass including painting of fittings and brackets cutting & making good the walls & floors wherever required. (a) Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern (14020.75*0.8345)

2

-

11115.3

... More
Providing & fixing pipes. (a) 100mm dia sand cast iron S & S Pipe (1008.2*0.8345)

25

-

799.28

... More
(b) 75mm dia sand cast iron S & S pipe (923.25*0.8345)

15

-

731.93

... More
Providing lead Caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fittings of diameters. (a) 100 mm (481.45*0.8345)

8

-

381.68

... More
(b) 75 mm (407.9*0.8345)

5

-

323.37

... More
Providing & fixing M. S. holder - bat clamps of approved design to sand Cast iron/cast iron (spun) pipe embedded in & including cement concrete blocks 10*10*10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). Including cost of cutting holes&making good the walls etc. (a) For 100 mm dia pipe (287.45*0.8345)

8

-

227.88

... More
(b) For 75 mm dia pipe (283.4*0.8345)

8

-

224.67

... More
Providing & fixing sand cast iron S&S trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting & making good the walls and floors. 100 mm inlet & 75 mm outlet (1202.15*0.8345)

16

-

953.03

... More
Providing & fixing Sand Cast iron S & S coller (a) 100 mm dia (365.3*0.8345)

3

-

289.6

... More
(b) 75 mm dia (265.7*0.8345)

2

-

210.64

... More
Providing & fixing sand cast iron S & S bend of required degree with access door insertion rubber washer 3 mm thick, bolts & nuts complete. 100 mm dia (461.65*0.8345)

4

-

365.98

... More
Providing & fixing plain sand cast iron S & S Bend of required degree. 100 mm dia (381.35*0.8345)

4

-

302.32

... More
Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. Internal work exposed on wall (a) 20mm nominal outer dia pipes (306.95*0.8222)

80

-

239.76

... More
(b) 32mm nominal outer dia pipes (480.55*0.8222)

60

-

375.35

... More
(c) 40mm nominal outer dia pipes (648.6*0.8222)

10

-

506.61

... More
Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chase and making good the wall etc. (a) 15mm nominal outer dia pipes (409.65*0.8222)

80

-

319.97

... More
(b) 20mm nominal outer dia pipes (478.15*0.8222)

70

-

373.48

... More
(c) 25mm nominal outer dia pipes (561.95*0.8222)

20

-

438.93

... More
Providing, fixing G. I. pipes complete with G. I. fittings and clamps including cutting and making good the walls etc. (internal work) - (Exposed on wall) (a) 20mm dia nominal bore

5

-

272.79

... More
(b) 25mm dia nominal bore

10

-

347.24

... More
(c) 32mm dia nominal bore

25

-

419.93

... More
Painting G. I. pipes and fittings with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work. (a) 20mm dia nominal bore (18.15*0.8222)

5

-

14.18

... More
(b) 25mm dia nominal bore (23.7*0.8222)

10

-

18.51

... More
(c) 32mm dia nominal bore (28.4*0.8222)

25

-

22.18

... More
Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) (a) 25 mm nominal bore (497.15*0.8222)

4

-

388.32

... More
(b) 32 mm nominal bore (581.25*0.8222)

4

-

454.01

... More
Providing and fixing ball valve (brass) of approved quality complete. (High or low pressure with plastic floats). (a) 25 mm nominal bore

4

-

312.35

... More
Providing & fixing 15 mm nominal bore 45 cm long unplasticised PVC connection pipe with brass unions. (83.00*0.8222)

6

-

64.83

... More
Providing & fixing 15 mm nominal bore CP brass bib cock of approved quality conforming to IS 8931.=(418.95*0.8345)

4

-

332.13

... More
Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. (618.80*0.8345)

7

-

490.57

... More
Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931. (532*0.8345)

7

-

421.76

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting and base support for tank. 1000 litres capacity

1000

-

6.98

... More
Constructing brick masonry chamber 300 x 300 x 500 mm, inside with F.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for Stop Cock, with C. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design (1582.45*0.8345)

1

-

1254.53

... More
EXTERNAL SEWERAGE SYSTEM Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil (364.2*0.8222) Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm.

30

-

284.47

... More
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. (a) 100mm diameter (317.05*0.8345)

5

-

251.35

... More
(b) 150mm diameter (500.20*0.8345)

25

-

396.55

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design. (a) 100mm dia SW pipe (817*0.8345)

5

-

647.7

... More
(b) 150mm diameter (999.15*0.8345)

25

-

792.1

... More
Providing and fixing square mouth S.W. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design. (2317.4*0.8345) a) 150 x 100 mm. size P type

4

-

1837.18

... More
Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. a) Inside size 90x80 cm & 45 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. (10905.05*0.8345)

4

-

8645.25

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar (422.20*0.8345)

5

-

334.71

... More
Providing white vitreous china urinal partition for half stall urinals. (Parryware C0571 or equivalent)

4

-

901.55

... More
Fixing of viterous china urinal partition complete

4

-

285

... More
Providing 450 mm long C. P. brass towel rail complete with C.P. brass brackets

2

-

285

... More
Fixing of C. P. brass towel rail

2

-

142.5

... More
Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps.

16

-

66.5

... More
Providing & fixing of hand lever operated forged brass full way ball valve type isolating valve having screwed ends tested to a pressure of 15 kg/sqcm complete. (Make : CIM) 20 mm nominal bore

2

-

498.75

... More
SUBHEAD I- WIRING POINTS Wiring points for light with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects.

155

-

579.5

... More
Same as item No.(1) but for fan and light duty exhaust fan.

35

-

637.45

... More
Same as item No.(1) but for 5 Amp plug point

25

-

310.65

... More
Supply & wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FR PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C.

250

-

114.95

... More
Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.

110

-

141.55

... More
SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.

28

-

133

... More
Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.

7

-

185.25

... More
S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.

28

-

142.5

... More
Supply fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.

28

-

491.15

... More
Supply & fixing of ceiling fitting fixed on matching M.D.F.E.G. Board base including connections with existing outlet. The base of ceiling fitting shall be fabircated from 22 gauge CRCA sheet in square shape finished with black matt surface complete with 3mm thick export quality acrylic moulded cover and heavy duty brass holder of Kinial/or any other approved make complete in all respects Category A

8

-

471.5

... More
Supply & fixing of single wall light bracket made of brass on matching polished MDFEG board brass including connection etc. as required.

14

-

1567.5

... More
S/F of LED tube light with batten suitable for up to 1X22 watt LED tube light fitting including tube on suraface complete in all respect. CAT-AAA

58

-

1130.5

... More
Supply & fixing of LED Tube Light with batten suitable for up to 2 x 22 watt LED tube light complete including tube etc on surface complete in all respects.(CAT: AAA)

3

-

1700.5

... More
SUBHEAD III-DISTIBUTION BOARD Construction of recess distribution board of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work. 600x480x200 mm. size

2

-

617.5

... More
Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer followed by two coats of synthetic enamel paint complete with necessary conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work. 600x480x200 mm. size

2

-

1634

... More
Supply and fixing of flush/surface mounting distribution boards without MCB with additional metal door complete in all respects. 6 Way TPN

8

-

4151.5

... More
Supply and fixing of 240 volts 'L' series miniature circuit breaker 6 Amp. To 32 Amp. (10 K A ) in existing MCB, DB complete with connections as required. 6 - 32 amps.

8

-

247

... More
Supply fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 40 Amp. 4P MCB (10 KA)

3

-

2161.25

... More
Supply and fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.

3

-

323

... More
Supply and fixing Single Pole MCBS Blanking Plate complete in all respects.

12

-

23.75

... More
Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.

1

-

5111

... More
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects.

75

-

85.5

... More
Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side.

95

-

199.5

... More
Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size.as per direction of Engineer-Incharge.complete in all respect The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sqmm 4 core

175

-

310.65

... More
Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. 10 sqmm 4 core

4

-

82.65

... More
Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 10 Sq.mm

8

-

19

... More
Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB’s. (Four Pole 36 KA with thermal magnatic release) Switches complete and instrument chamber etc. complete in all respects. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm CUBICAL PANEL BOARD ( MCCB TYPE ) a) L.T.Panel Incoming : One (1) No 400 A 4 pole Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-400A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No.315A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 200Amps TPN - 1No. 100Amps TPN - 2No. 15Amps TPN - 1Nos OR outgoing as per site requirment/CAT B CUBIC TYPE

1

-

83125

... More
Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules.

1

-

80.75

... More
Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.

2

-

2422.5

... More
Supply and fixing 400 AMP four pole Moulded case type on load change over switch with enclosure(also suitable for panel mounting with extra cost of bus bar) including the cost of labour, T & P , painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.-

1

-

21470

... More
Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair

75

-

19

... More
Supply and erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan with regulater standar down rod, blades including connection etc. complete as required

28

-

1852.5

... More
Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep.

7

-

1567.5

... More
SEPTIC TANK Earth work in excavation

23.7

-

99.75

... More
P.C.C. in Foundation (1:4:8)

1.07

-

4655

... More
First Class Brick work in septic tank (1:4)

8.65

-

4465

... More
R.C.C. work in septic tank Slab cover of septic tank

0.88

-

6507.5

... More
M.S. work in R.C.C.

0.69

-

5225

... More
15 mm th plastering inside septic tank

29.88

-

252.85

... More
Centring and shuttering including struting , proping etc and removal of form for slab.

4.5

-

541.34

... More
Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.

6

-

334.71

... More
Providing & fixing soil waste and vent pipe.

1

-

731.93

... More
Providing & fixing sand cost iron terminal guard 75 mm dia.

1

-

225.46

... More
providing lead caulked joints to sand cost iron/centrifugally cast(squn) iron pipes and fitting of dia. 75 mm

1

-

323.37

... More
S.W. Tee 100 mm dia with one leg of 40 cm with fixing in inlet and outlet

2

-

161.5

... More
75 mm dia cowl at top of ventilating pipe

1

-

192.85

... More
Supply & fixing of medium quality R.C.C. Manohole cover with frame complete.HD.Circular shape, 560 int. dia

2

-

1166.57

... More
M.D.-2.5 Circular shape , 450 int. dia.

1

-

975.59

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.

1

-

20040.36

... More
TUBE WELL AND INSTALLATION OF SUBMERSIBLE PUMP Drilling of 200 mm dia bore hole.

76

-

475

... More
Lowering of 113 mm dia blue casing pipe.

66

-

142.5

... More
Development of tubewell

1

-

4750

... More
Installation of pump 1.5 HP

1

-

4750

... More
Shifting of Machine of boring

1

-

2375

... More
Supply of Blue casing pipe 113mm

52

-

427.5

... More
Supply of Blue casing ripped screen 113mm

15

-

380

... More
Supply of P.V.C. end cap 110mm

1

-

142.5

... More
Supply of P.V.C. dori

1

-

128.25

... More
Supply of 32mm G.I. pipe

42.65

-

192.85

... More
Supply of Reducer bush 40x32

1

-

61.75

... More
Supply of M.S. Socket 32mm

5

-

90.25

... More
Supply of Boring cover 100mm

1

-

156.75

... More
Supply of Clamp 32mm

1

-

152

... More
Supply of 2.0 HP Varuna make Submersible pump

1

-

23750

... More
Supply of Varuna control panel 1.5 /1.0 H.P.

1

-

7125

... More
Supply of 1.5sqmm cable

50

-

30.88

... More
Supply of 20mm ball valve

1

-

332.5

... More
Supply of 20mm G.I. Nipple

1

-

33.25

... More
Supply & filling of P gravel in boring out side of PVC pipe complete in all respect

1.75

-

4275

... More
Earth filling

571.23

-

292.6

... More
GST Extra as per applicable

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.