If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Projects Corporation Limited - UPPCL Tender
Civil And Construction
Healthcare and Medicine
Building Construction
Eprocure
Opening Date9 Jan 2025
Closing Date24 Jan 2025
Tender Amount₹ 3,92,68,000
Costs
EMD
₹ 7,85,000Document Cost
₹ 17,700Tender Fee
Refer Documents
Summary
Sitc Of Balanced Medical Equipment/medical Gas Pipe Line System And Other Work Of Units/departments At Newly Construction Building Centre For Orthopedic Super Specialities Bhawan, K.g.m.u. Lucknow.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_UPPRC_991770_1Tender No
59/UPPCL/GM-7/E-TENDER/2024-25 Dated-07.01.2025Tender Authority
Uttar Pradesh Projects Corporation Limited ViewPurchaser Address
-Website
http://http://upprojects.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Installation & testing
-
-
-
... More
Installation of piping shall be carried out with almost cleanliness. Only pipes, fittings and values that have been degreasedand fittings shall be used at site. Pipe fixing clamps shall be of nonferrous or nondeteriorating plastic suitable for the diameter of the pipe insert gas welding technique should be used by passing oxygen free Nitrogen gas inside the copper pipes during silver brazing, in order to avoid carbon deposition inside the copper pipes during silver brazing, in order to avoid carbon deposition inside the copper pipes only copper to copper joints are permitted on site except threaded or flanged joints may be made where pipelines are connected to itens such as values and control equipment. no flux shall be used for joining copper to copper joints and on for joints made on site. Copper to copper joints shall be blazed using a 5% silver-copper phosphorous brazing alloy CP104. A total of 5 joints shall be cut out for examination to establish the quality of the joints being made on site. the insides shall be clean and free from oxides and particulate matter and the minimum penetration of the brazing alloy at any point shall be three times the wall thickness of the tube.
-
-
-
... More
If the joints examined do not confirm to these requirnments, then adjacent joints shall be cut and examined until the extent of faulty workmanship has been made good. Copper to brass or gunmetal joints shall only be made under controlled conditions off site. the joints are ordinarily used to join short copper pipe tails to brass, gunmetal or bronze fittings to permit their connection into the pipeline. the sub-assemblies shall be degreased and individually sealed in the bags or boxes before delivery to site.
-
-
-
... More
Painting
-
-
-
... More
All the pipes from manifold/plant unto the outlets should be painted with two coats of synthetic enamel paint and colour codification should be as per standards followed and with consultation with competent authorities of the Institute.
-
-
-
... More
108 mm OD X 1.5 mm thick (manifold room to towards ward)
51
-
-
... More
108 mm OD X 1.5 mm thick (for connection from LMO to manifold room)
125
-
-
... More
76 mm OD X 1.5 mm thick
53
-
-
... More
54 mm OD X 1.2 mm thick
16
-
-
... More
42 mm OD X 1.2 mm thick
75
-
-
... More
35 mm OD X 1.2 mm thick
350
-
-
... More
28 mm OD X 1.2 mm thick
270
-
-
... More
22 mm OD X 1 mm thick
871.5
-
-
... More
15 mm OD X 1 mm thick
1443.4
-
-
... More
12 mm OD X 1 mm thick
390
-
-
... More
Gas outlet points / Terminal Units with probe
-
-
-
... More
Terminal units ( Gas outlet ) with probes / Adaptors for O2, N2O, Compressed Air 4, Air 7, AGSS, Vacuum & CO2 (CO2 can be optional depending on the requirement ) The Medical gas outlets shall confirm to HTM 02-01 / NFPA 99 C / EN / DIN / ISO 7396 -1. Front loading type Terminal outlets should be designed to dispence medical gases (or an inlet for medical vacuum) to the secondary equipment ( flow meters, suction regulators, etc.) at the point of use and is gas specific so that secondary devices cannot be "attached " to the wrong gas. The outlet should be made of full metal without any plastic parts. When not in use the gas in a non- flowing state within the outlet (Terminal unit) sealed by "O" ring. The adapter when inserted pushes the poppet inside and the gas starts flowing and sealing is ensured by the "O" ring or a seat. The outlets are Quick Connect Type and gas specificity is accomplished by "Pin indexing." The outlets should have following features:
-
-
-
... More
• Push to insert and press-to-release mechanism for probes.
-
-
-
... More
• Allow plugging of probes from front.
-
-
-
... More
• Self- sealing valve on disengaging the probe (Quick disconnect)
-
-
-
... More
• Smooth quick action
-
-
-
... More
• Non-return valve for on line servicing / repairing
-
-
-
... More
• Indexed to eliminate inter-changeability of gas services
-
-
-
... More
• Colour-coded gas specific front plate
-
-
-
... More
• Totally leak proof, safe & easy to operate
-
-
-
... More
• Configuration possible: surface, flush & Bread- head.
-
-
-
... More
• Outlets should be US FDA / European CE Certificate with 4 digit notified body number or American ETL / American LII listed
-
-
-
... More
Oxygen outlet with probe
280
-
-
... More
Nitrous Oxide outlet with probe
3
-
-
... More
Medical Air 4 outlet with probe
7
-
-
... More
Vaccum outlet with probe
198
-
-
... More
Medical Air 7 outlet with probe
6
-
-
... More
Control and Reducer Panels with Medical Gas Alarms, NIST connection and valves:
-
-
-
... More
The second stage reducer panels should fully comply and meet HTM 02-01 / NFPA99C /EN /DIN /ISO 7396 standards. It should control and isolate medical gases (O2, N2O, Air, CO2) that feed the gas outlets. High pressure regulator (high flow) should be in the central station that will reduce the pressure from the cylinders from 200 bar to 8 bar. The regulator should be made of brass. The flowrate must be at least 150 m3/h at 10 bar. It should have integrated manometer and pressure sensor, and a safety valve set up at 12.5 bar. It shall have brass intake filter for easy service and repair. Middle / Low pressure regulator (in up to 21 bar out 8 or 4 bar). These reducers shall be placed either in the central section if the distribution is one stage or indeoendetly and should reduce the pressure from 8 bars to 4-5 bars the block of pressure reducers shall be made from aluminium. The block shall consist of 2 pressure reducers in parallel layout. It shall have integrated ball valve switches from stainless steel ball with aluminium housing, an integrated brass safety valve and a NIST outlet, 2 intake brass filters, a manometer and a pressure sensor transmitter 4-20 mA. It should have metallic base for mounting. The maximum inlet pressure should be 21 bar and the flowrate of the whole block must be at least 280 m3/h @8 bars (2x140m3/h) Low pressure Regulator (in 10 bar out 4-5 bar) should be a local 2nd stage reducer located outside of the ward for reducing or/and stablizing the pressure. The block should have 2 pressure reducers in parallel layout, for space redundancy reasons and for easy service. it should have integrated ball valve switches from stainless steel ball with aluminium housing a NIST.
-
-
-
... More
Valve Box - 2 Gas service with NIST Connection
15
-
-
... More
Valve Box - 5 Gas service with NIST Connection
2
-
-
... More
LINE ISOLATION VALVES
-
-
-
... More
The line valves must be degreased and complies with HTM 02-01/ NFPA 99 C/EN//DIN/ISO 7396-1 standard. It should be CE certificate with 4 digit notified body
-
-
-
... More
12 mm ball valve
462
-
-
... More
22 mm ball valve
9
-
-
... More
28 mm ball valve
10
-
-
... More
35 mm ball valve
9
-
-
... More
42 mm ball valve
10
-
-
... More
54 mm ball valve
3
-
-
... More
108 mm ball valve
4
-
-
... More
Oxygen Flowmeter with humidifier bottle
-
-
-
... More
Back pressure compensated flow meter for accurate gas flow measurement with following features: a. control within a range of 0-15 LPM. B. It should meet strict precision and durability standard. C. The flow meter body should be made of clear, impact resistant polycarbonate. e. Flow tube should have large and expanded 0-15 LPM range for improved readability at low flows. f. Inlet filter of stainless steel wire mesh to prevent entry of foreign particles. g. The humidifier bottle is made of unbreakable & reusable polycarbonate / polysulfone material autoclavable at 121 degree centigrade.
348
-
-
... More
Ward vaccum Unit with jar
-
-
-
... More
It must consist of the following:
-
-
-
... More
1. 1 no of Suction Regulator and 1 no of 1000 ml polysulfone / polycarbonate collection jar.
-
-
-
... More
2. Suction Regulator: Suction regulator should be supplied with a safety jar, including and and antibacterial filter and anti- overflow safety device. Should have wide membrane continious suction controller.
-
-
-
... More
3. Shold have vaccum level : 0-760 mm of Hg
-
-
-
... More
4. Should have vaccum gauge fitted with a protective bumper device
-
-
-
... More
5. Should have on / of knib allowing for the quick restoration of a readjusted vaccum level.
-
-
-
... More
6. Should have central adjustment knob with a colour coded for 0 to 760 mm of Hg. Should have polysulfone / polycarbonate 100 cc safety jar, autoclavable at 121° at 5 mins, unbreakable, fitted with an anti- overflow safetyb device and equipped with a plastic antibacterial filter. It should be transparent, o ensure perfect sucked liquid visibility.
204
-
-
... More
Optical Particle Counter (Portable)
-
-
-
... More
Monitoring clean environments for quality assurance and assessing air quality for productivity, health & safety bin size 0.3 to 10 µm, user adjustable ,calibrated at 0.3 ,0.5, 1, 3, 5, and 10 Microns.
Counting efficiency-
50% ± 10% at 0.3 µm
100% by 0.45 µm
meets or exceeds JIS standards.
Data logging- More than 100000 indevidual sample sets. Connectivity- USB compalible.
Make & brand- Highly reputed in particular field & 3 years.
1
-
-
... More
Automatic Control Panel for LMO
-
-
-
... More
Liquid oxygen to gas manifold Automatic control panel, 2000 lpm deliver capacity with necessary controls and safety fittings. The fully automatic oxygen control panel should comply with HTM 02-01/NFPA 99C/ DIN / EN / ISO-7396- 1 standards. It should be CE Certificate.
1
-
-
... More
X- Ray View Screen
-
-
-
... More
Supply, installation, testing & commissioning of Twin Plate X- Ray viewing screen designed to provide a high level of control luminance without Flickering & as per the technical specifications attached. X- ray view screen ( two scren ) LED Overall dimensions (LxHxT) 880 x 503 x 29 mm View area (WxH) : 736 x 440 mm light source : LED Power consumption / input power : 30 W / AC 100-240 V Illumination intensity : 5,500 LUX approx.
2
-
-
... More
Writing White Board
-
-
-
... More
Supplying & fiing of sturdy writing board of size : 840 mm x 640 mm with perfect marker riting surface in front and back is laminated to make water proof surface. The board has to be provided with antodized aluminium framing and its back should have hooks for wall hanging of approved make and type directly on wall & as per techical specs attached.
2
-
-
... More
HOMOGENEOUS FLOORING CORRIDOR AREA
375
-
-
... More
Anesthetist Pendant- CE Certificate
-
-
-
... More
The ceiling pndant system will be desiged to provide convenient positioning f medical equipment, medical gas terminal units, electrical and electrical switch / completely made of metal.The pendent will have double arm. It will have weight carrying capacity of minimum 100 kg. The pendent will have minimum 6 electrical sockets, at least one monitor shelf and minimum 6 gas outlets for medical gas supply.
6
-
-
... More
Surgeon Pandant- CE Certified
-
-
-
... More
The ceiling pndant system will be desiged to provide convenient positioning f medical equipment, medical gas terminal units, electrical and electrical switch / completely made of metal.The pendent will have double arm. It will have weight carrying capacity of minimum 100 kg. The pendent will have minimum 6 electrical sockets, at least one monitor shelf and minimum 6 gas outlets for medical gas supply.
5
-
-
... More
Operation Theatre Light - LED type, Camera Ready (Triple Arm)
-
-
-
... More
Operating Room Surgical Lighting system should provde an ideal combination of broghtness, maneuverability, and shadow resolution without sacrificing color accuracy throuh a consistent LED technology. Such Lighting System should have the following technical specifications:
-
-
-
... More
a. Number of light heads : Two per suspension
-
-
-
... More
b. Colour Temperature range : 3800k-5000 (±10%) - Variable color temperature.
-
-
-
... More
c. Field Size Diameter : 20 to 28 cm (+/- 10%)
-
-
-
... More
d. Working range : 750 to 11100 mm (+/- 10 %)
-
-
-
... More
e. Illumination Level : 160000Lux (major Dome & Minor dome )
-
-
-
... More
f. Rotation : 360 - 330 degree
-
-
-
... More
g. Sterilizable Handle : 02 Nos
-
-
-
... More
h. Mounting type : Ceiling
-
-
-
... More
i. Supply Voltage : 230 VAC 50 Hz
-
-
-
... More
j. Bulb Type : LED
-
-
-
... More
k. Dimming Range : 50% - 100%
-
-
-
... More
l. Operating / Storage Humidity : 10 - 95 %
-
-
-
... More
m. Life of Light source : 40,000 Hrs
-
-
-
... More
n. Should be provision to mount the camera in 1 dome .
-
-
-
... More
o. Surgical Light System Should be compliant with relevant European CE / US FDA standards.
6
-
-
... More
GST Extra as applicable
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%