Uttar Pradesh Projects Corporation Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Projects Corporation Limited - UPPCL Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date13 Aug 2024
Closing Date27 Aug 2024
Tender Amount₹ 61,88,000
Costs
EMD
₹ 1,24,000Document Cost
₹ 11,800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UPPRC_932847_4Bid Award Id
ViewTender No
28/PCL/GM/Zone-6/Noida/2024-25 Dt. 25.06.2024Tender Authority
Uttar Pradesh Projects Corporation Limited ViewPurchaser Address
-Website
http://http://upprojects.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction work of Proposed Medical Gas Pipe Line System for Emergency ,General, I.C.U and Pedeatric Block of Pt. Deendayal Upadhyal Hospital Bijnor attached with MVASMC BIJNOR
BOQ Items
VACUUM SYSTEMS OUTLET POINT GAS OUTLET WITH PROBE FOR AIR OUTLET SUPPLY SHOULD CONFIRM HTM 02-01/ NFPA 99c /EN/DIN/ISO 7396-1 & US FDA APPROVED. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020) VACUUM OUTLET WITH PROBE
29
115756
3991.6
WARD VACUUM UNIT 600ML JAR WITH VACUUM REGULATOR
29
115756
3991.6
L.P TUBE MADE UP ANTISTATIC RUBBER FOR CONNETION TO OUTLET POINT
58
9748
168.07
H.P TUBE MADE UP ANTISTATIC RUBBER FOR CONNETION TO OUTLET POINT
29
4874
168.07
BED HEAD PANEL 4 GAS OUTLET WITH ACCESSORIES
27
1134453
42016.81
(IV STAND - 1 NO, INFUSION PUMP POLE-1 NO,MONITOR TRAY-1 NO,VACUUM SLIDER-1 NO, 2 NOS ELECTRICLA SWITCH SOCKET AND PANEL LENTH 1500 MM MEDICAL GRADE COPPER PIPE SYSTEM WITH COPPER FITTINGS AND PROPER COLOR CODING. copper pipe should be colour coded deoxidized,non arsenical degreased and capped at both end and should comply with BS:EN 13348:2008/ASTM8819 EN 1254:1& EN 1044standards must have a third party inspection certificate (Lloyd's or TUV or SGS) (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020)
15 mm x0.9 mm thk
168.9
76927
455.46
Same as above but 22 mm x 0.9 mm thk
315
205172
651.34
Same as above but 28 mm x 0.9 mm thk
123
206722
1680.67
Digital Area Line Presure Alarm should be US FDA approved complies with HTM 02-01/NFPA 99c/EN/DIN/ISO 7396-1/EMC Standard. (Specifications as per GO Dated 03-12-2020 & 29-05-2021)
Area Line Presure Alarm upto 3 gases
5
134453
26890.76
AREA VALVE SERVICE UNIT.
Area valve service unit should fully comply and meet with HTM 02-01/NFPA 99c/EN/DIN/ISO 7396-1. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020 attached)
3 Gas Services
5
94537
18907.56
Isolation Ball valve with both sides end fittingsThe lockable line valves must degreased and complete valve with stuffed pipe & fitting factory tested and complines with HTM 02-01/NFPA 99c/EN/DIN/ISO 7396-1 Standard. 22 mm
1
2058
2058.82
Same as above but 28 mm
1
2924
2924.37
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
100
24589
245.89
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints
etc. complete
100
38854
388.54
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia
20
14547
727.37
GENERAL I.C.U.
GAS OUTLET POINT : GAS OUTLET WITH PROBE FOR OXYGEN SUPPLY SHOULD CONFIRM HTM 02-01/ NFPA 99c /EN/DIN/ISO 7396-1 & US FDA APPROVED. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020 attached) OXYGEN OUTLET WITH PROBE
24
95798
3991.6
OXYGEN METAL BODY FLOW METER WITH HUMIDIFIER BOTTEL.
12
29344
2445.38
It should be of metal body flowmeter of brass/nicklecrome with the control within a range of 0-15LPM,back pressure compensated flowmeter for accurate gas flow System Should follow BIS/CE certificate/UL listed. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020)
OUTLET POINT GAS OUTLET WITH PROBE FOR AIR OUTLET SUPPLY SHOULD CONFIRM HTM 02-01/ NFPA 99c /EN/DIN/ISO 7396-1 & US FDA APPROVED. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020) AIR OUTLET WITH PROBE (AIR 4 BAR )
12
47899
3991.6
VACUUM SYSTEMS OUTLET POINT
GAS OUTLET WITH PROBE FOR AIR OUTLET SUPPLY SHOULD CONFIRM HTM 02-01/ NFPA 99c /EN/DIN/ISO 7396-1 & US FDA APPROVED. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020)
VACUUM OUTLET WITH PROBE
12
47899
3991.6
WARD VACUUM UNIT 600ML JAR WITH VACUUM REGULATOR
12
47899
3991.6
L.P TUBE MADE UP ANTISTATIC RUBBER FOR CONNETION TO OUTLET POINT
24
4033
168.07
H.P TUBE MADE UP ANTISTATIC RUBBER FOR CONNETION TO OUTLET POINT
12
2016
168.07
BED HEAD PANEL 4 GAS OUTLET WITH ACCESSORIES
12
504201
42016.81
(IV STAND - 1 NO, INFUSION PUMP POLE-1 NO,MONITOR TRAY-1 NO,VACUUM SLIDER-1 NO, 2 NOS ELECTRICLA SWITCH SOCKET AND PANEL LENTH 1500 MM MEDICAL GRADE COPPER PIPE SYSTEM WITH COPPER FITTINGS AND PROPER COLOR CODING. copper pipe should be colour coded deoxidized,non arsenical degreased and capped at both end and should comply with BS:EN 13348:2008/ASTM8819 EN 1254:1& EN 1044standards must have a third party inspection certificate (Lloyd's or TUV or SGS) (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020)
15 mm x0.9 mm thk
80.4
36618
455.46
Same as above but 22 mm x 0.9 mm thk
163
106168
651.34
Digital Area Line Presure Alarm should be US FDA approved complies with HTM 02-01/NFPA 99c/EN/DIN/ISO 7396-1/EMC Standard. (Specifications as per GO Dated 03-12-2020 & 29-05-2021) Area Line Presure Alarm upto 3 gases
1
26890
26890.76
AREA VALVE SERVICE UNIT.
Area valve service unit should fully comply and meet with HTM 02-01/NFPA 99c/EN/DIN/ISO 7396-1. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020) 3 Gas Services
1
18907
18907.56
Isolation Ball valve with both sides end fittings
The lockable line valves must degreased and complete valve with stuffed pipe & fitting factory tested and complines with HTM 02-01/NFPA 99c/EN/DIN/ISO 7396-1 Standard. 22 mm
1
2058
2058.82
Same as above but 28 mm
1
2924
2924.37
PEDEATRIC BLOCK
GAS OUTLET POINT : GAS OUTLET WITH PROBE FOR OXYGEN SUPPLY SHOULD CONFIRM HTM 02-01/ NFPA 99c /EN/DIN/ISO 7396-1 & US FDA APPROVED. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020) OXYGEN OUTLET WITH PROBE
52
207563
3991.6
OXYGEN METAL BODY FLOW METER WITH HUMIDIFIER BOTTEL.It should be of metal body flowmeter of brass/nicklecrome with the control within a range of 0-15LPM,back pressure compensated flowmeter for accurate gas flow System Should follow BIS/CE certificate/UL listed. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020)
44
107596
2445.38
OUTLET POINT
GAS OUTLET WITH PROBE FOR AIR OUTLET SUPPLY SHOULD CONFIRM HTM 02-01/ NFPA 99c /EN/DIN/ISO 7396-1 & US FDA APPROVED. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020)
AIR OUTLET WITH PROBE (AIR 4 BAR )
44
175630
3991.6
VACUUM SYSTEMS OUTLET POINT GAS OUTLET WITH PROBE FOR AIR OUTLET SUPPLY SHOULD CONFIRM HTM 02-01/ NFPA 99c /EN/DIN/ISO 7396-1 & US FDA APPROVED. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020) VACUUM OUTLET WITH PROBE
44
175630
3991.6
WARD VACUUM UNIT 600ML JAR WITH VACUUM REGULATOR
44
175630
3991.6
L.P TUBE MADE UP ANTISTATIC RUBBER FOR CONNETION TO OUTLET POINT
88
14790
168.07
H.P TUBE MADE UP ANTISTATIC RUBBER FOR CONNETION TO OUTLET POINT
44
7395
168.07
BED HEAD PANEL 4 GAS OUTLET WITH ACCESSORIES (IV STAND - 1 NO, INFUSION PUMP POLE-1 NO,MONITOR TRAY-1 NO,VACUUM SLIDER-1 NO, 2 NOS ELECTRICLA SWITCH SOCKET AND PANEL LENTH 1500 MM
8
336134
42016.81
MEDICAL GRADE COPPER PIPE SYSTEM WITH COPPER FITTINGS AND PROPER COLOR CODING. copper pipe should be colour coded deoxidized,non arsenical degreased and capped at both end and should comply with BS:EN 13348:2008/ASTM8819 EN 1254:1& EN 1044standards must have a third party inspection certificate (Lloyd's or TUV or SGS) (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020)
15 mm x0.9 mm thk
218.8
99654
455.46
Same as abve but 22 mm x 0.9 mm thk
163.2
106298
651.34
Same as abve but 28 mm x 0.9 mm thk
20
33613
1680.67
Digital Area Line Presure Alarm should be US FDA approved complies with HTM 02-01/NFPA 99c/EN/DIN/ISO 7396-1/EMC Standard. (Specifications as per GO Dated 03-12-2020 & 29-05-2021)
Area Line Presure Alarm upto 3 gases
6
161344
26890.76
AREA VALVE SERVICE UNIT.
Area valve service unit should fully comply and meet with HTM 02-01/NFPA 99c/EN/DIN/ISO 7396-1. (Specifications as per GO No.154/2020/4082/71-1-2020-G-307/2017TC Dated 03-12-2020)
3 Gas Services
6
113445
18907.56
Isolation Ball valve with both sides end fittings The lockable line valves must degreased and complete valve with stuffed pipe & fitting factory tested and complines with HTM 02-01/NFPA 99c/EN/DIN/ISO 7396-1 Standard. 22 mm
1
2058
2058.82
Same as above but 28 mm
1
2924
2924.37
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements