Uttar Pradesh Projects Corporation Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Projects Corporation Limited - UPPCL Tender

Works
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date16 Jan 2025
Closing Date21 Jan 2025
Tender Amount₹ 17,95,43,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 450 mm dia piles

536

2134

1144183.12

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.

-

-

-

... More
Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.

-

-

-

... More
Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.

-

-

-

... More
Group of two or more piles upto 50 tonne Safe capacity

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity)

11

54686

601548.53

... More
Routine test (Test Load 1.5 times the Safe capacity)

2

31486

62972

... More
Cement concrete with 40 mm gauge approved stone , ballast approved coarse sand and cement in the proportion of 4:2:1 including supply of all materials, labour and T&P etc- required for proper completion of the work.

645.96

5510

3559239.6

... More
Centering and shuttering including strutting, propping etc. and removal of form for

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

1041.99

254

264967.64

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

880.2

552

486627.37

... More
Suspended floors, roofs, landings, balconies and access platform

516.28

632

326789.75

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

549.82

502

276191.08

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

453.55

664

301198.02

... More
Arches, domes, vaults up to 6 m span

169.84

1507

256115.32

... More
Extra for arches, domes, vaults exceeding 6 m span

173.22

475

82279.5

... More
M.S (tor steel or plain) in plain work such as RCC or R.B. work including bending for propoer shape and including supply of steel and its wastage bend, hooks and authorised overlapping shall be measured and including cost of binding wire.

5452.85

7530

41063395.8

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum

2406.46

7170

17255425.17

... More
All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum

370.71

8510

3154786.59

... More
Supply & fixing of Kota stone in flooring 20 mm thick & joint filled with 1:2 cement & coarse sand with approved colouring materials to be given & even shade with 12 mm base coat (bedding) of 1:2 cement & coarse sand mortar & polished by hand or machine & finally finished with french manson polish or other approved polish including supply of all materials, labour T & P etc. required for proper completion of the work excluding base concrete.

1825.11

1185

2163850.42

... More
Supply & fixing 10 to 12 mm thick Kota Stone tiles in skerting or dado laid with 1:2 cement & approved coarse sand mortar finished with in its cement coloured slurry jointed & polishing of approved quality complete including suplly of all material, labour & T & P & etc. required for proper completion of the work.

194.16

1363

264688.62

... More
40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.

-

-

-

... More
Red sand stone

321.79

1066

343298.44

... More
White sand stone

2306.04

1091

2516258.61

... More
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.

1147.36

129

149076.48

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :

-

-

-

... More
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

219.8

2138

470053.29

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent

332.14

3227

1072018.39

... More
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - Exposed face machine cut and table rubbed with rough backing. 30 mm thick

1741.16

5001

8708307.27

... More
Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone

140.6

10108

1421228.39

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

2108.18

505

1065790.4

... More
Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg / cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite / borer proof, water / moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately.

140.8

2590

364674.82

... More
Stone Benches

15

19000

285000

... More
Portable Cabin for Guard Room

1

55100

55100

... More
GFRC Jali

29.52

6646

196212.65

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :

-

-

-

... More
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

673.47

137

92783.96

... More
Providing & Applying white cement based putty of average thickness of 1mm, of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth including cost of material, labour & T & P etc. complete.

808.16

102

82650.52

... More
Finishing walls with textured exterior paint of required shade :

-

-

-

... More
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

134.69

202

27247.79

... More
M.S or iron work in heavy sizes for such as Trusses, built up gates, record racks, roof work, Gates etc. Including rivetting or welding where necessary Excluding GST

10.2

6270

63954

... More
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works

24

45

1099.92

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :

-

-

-

... More
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

24

158

3792.96

... More
Earth work in filling including cartage upto 8 km and loading & unloading including cost of earth etc. complete.

1141.84

411

469695.88

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30

51.81

2194

113716.21

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

259.05

834

216298.98

... More
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement

124.12

957

118888.34

... More
Dry Stone Pitching 105.00 cm thick including supply of stones and preparing surface complete 713.56*105/22.5=3329.95

3329.95

4514

15032626.38

... More
Sand filling in plinth including supply of necessary quantity of coarse sand to the site of work including watering, ramming, dressing etc. rate to include cost of all material, Labour T & P etc. required for proper completion of the work. (Under floor)

2471.03

636

1572810.6

... More
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).

38.06

74

2824.05

... More
Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment).

34.25

279

9566.03

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) :

-

-

-

... More
Screened through sieve of I.S. designation 4.75 mm

34.25

303

10408.92

... More
Rough dressing the trenched ground including breaking clods.

126.86

1

181.41

... More
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.

126.86

4

591.17

... More
Fine dressing of the ground.

126.86

3

446.55

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

38.06

49

1892.72

... More
Grassing with selection No. 1/Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and earth shall be paid for separately). In rows 5 cm apart in both directions

126.86

16

2133.79

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :

-

-

-

... More
Holes 90 cm dia, and 90 cm deep

10

135

1359.5

... More
Holes 60 cm dia, and 60 cm deep

65

41

2701.4

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)

-

-

-

... More
Trees Plant

10

6

69.4

... More
Shrubs Plant

65

3

225.55

... More
Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge

5

61

308.75

... More
Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge.

5

114

570

... More
Providing and stacking of Ficus blackii (F.vivion) (bushy) of height 150-165 cm. with 8-10 branches and healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge.

10

237

2375

... More
Providing and stacking of Ficus panda of height 30-45 cm. with 3-4 branches and healthy foliage in p.bag of size 20 cm as per direction of the officer-in-charge.

10

33

332.5

... More
Providing and stacking of Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge.

10

19

190

... More
Providing and stacking of Hibiscus rosasinensis of height 60-75 cm. with 5-6 branches in p.bag of size 25 cm as per direction of the officer-in-charge.

10

42

427.5

... More
Providing and stacking of Murraya exotica of height 45-60 cm. in poly bags of size 15 cm as per direction of the officer-in-charge

10

14

142.5

... More
Providing and stacking of Nerium oleander variegated of height 60-75 cm., multibranched in earthen pots of size 25 cm as per direction of the officer-in-charge.

5

57

285

... More
Providing and stacking of Tecoma gaudichaudi of height 60-75 cm. with 5- 6 branches in p.bag of size 25 cm as per direction of the officer-in-charge

5

47

237.5

... More
Providing and stacking of Thuja compacta of height 75-90 cm., conical shaped, well formed with healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge. in earthen pots of size 25 cm as per direction of the officer-in-charge.

5

123

617.5

... More
(B) RAIN WATER HARVESTING

-

-

-

... More
Excavation in foundation in ordinary Soil (Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth as directed by the engineer I/C within a lead of 30 m. from foundation trenches.

53.6

152

8147.2

... More
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds lof soil

-

-

-

... More
1.5 m to 3.0 m

24

23

570

... More
13.0 m to 4.50 m

11.2

23

266

... More
Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone aggregate 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.

0.7

4655

3258.5

... More
R.C.C. work with cement approved coarse sand and 2 cm Gauge approved stone ballast in the proportion of 1:1.5:3 (1cement: 1.5coarse sand: 3stone ballast) in Slab, excluding supply of reinforcement and its bending with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and T&P| etc. required for proper completion of the work.

0.88

8835

7774.8

... More
Class-150 brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour tools and plants, etc. required for proper completetion of the work.

13.34

4940

65899.6

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. In Slab

0.46

7530

3464.09

... More
(20 mm cement plaster in single coat of fair side of single or half brick wall for interior plastering upto floor two level including] internal rounded angles chamfers, and/or rounded angles not exceeding 80 mm. In girth and finished even and smooth. No extra for making any additive. 1:4 (1 cement: 4 coarse sand) In Plinth

31

205

6361.2

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar

32

380

12175.36

... More
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg

1

2654

2654.78

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia

27

683

18456.39

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia

18.9

801

15139.85

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia

10.6

906

9609.75

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

1.88

1074

2019.18

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

1.88

1079

2029.57

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.

1.88

1079

2029.57

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Boring Volume Pipe Volume

2.55

1219

3110.92

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

10

756

7561.1

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm dia

1

231

231.71

... More
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).

-

-

-

... More
200 mm dia

1

254

254.47

... More
Earth work in excavation for pipe line

114

344

39237.66

... More
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : mortar in the proportion of (1:1). 150 mm diameter

114

487

55602.36

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe

114

903

102963.66

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: inspection chamber and bends in cement mortar (1:4). Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : for pipe line with three or more inlets With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

11

7103

78138.28

... More
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

4609

4609.73

... More
(C) RETAINING WALL - 6 Meter Height

-

-

-

... More
EXCAVATION in foundation in ordinary soil (loam clay or sand ) including lift upto 1.5m lead upto 30.0m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth as directed by the engineer I/C within a lead of 30 m. from foundation trenches.

1388.49

152

211050.48

... More
Add to item 251 for every additional 30 mtr. Lead or part of 30 mtr. Or for every additional 1.50 mtr lift or part of 1.50 metre.

1041.37

175

183020.78

... More
Add to item 251 for every additional 30 mtr. Lead or part of 30 mtr. Or for every additional 1.50 mtr lift or part of 1.50 metre.

694.25

351

244028.88

... More
Add to item 251 for every additional 30 mtr. Lead or part of 30 mtr. Or for every additional 1.50 mtr lift or part of 1.50 metre.

347.12

527

183019.02

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

1153.34

209

241843.86

... More
Cement concrete with 4cm gauge approved stone , ballast approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc- required for proper completion of the work.

15.68

4655

72990.4

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level

219.47

7170

1573700.86

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns

14.93

254

3796.55

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

59.72

254

15186.2

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

813.69

552

449856.65

... More
M.S (tor steel or plain) in plain work such as RCC or R.B. work including bending for propoer shape and including supply of steel and its wastage bend, hooks and authorised overlapping shall be measured and including cost of binding wire. Excluding GST

404.62

7530

3047043.51

... More
(D) RETAINING WALL - 2.70 Meter Height

-

-

-

... More
EXCAVATION in foundation in ordinary soil (loam clay or sand ) including lift upto 1.5m lead upto 30.0m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth as directed by the engineer I/C within a lead of 30 m. from foundation trenches.

474.27

152

72089.04

... More
Add to item 251 for every additional 30 mtr. Lead or part of 30 mtr. Or for every additional 1.50 mtr lift or part of 1.50 metre.

210.79

175

37046.34

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

367.19

209

76996.07

... More
Cement concrete with 4cm gauge approved stone , ballast approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc- required for proper completion of the work.

10.81

4655

50320.55

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum

96.27

7170

690300.18

... More
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns

13.51

254

3435.46

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

54.05

254

13744.37

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

297.26

552

164343.16

... More
M.S (tor steel or plain) in plain work such as RCC or R.B. work including bending for propoer shape and including supply of steel and its wastage bend, hooks and authorised overlapping shall be measured and including cost of binding wire. Excluding GST

177.33

7530

1335406.62

... More
(E) RETAINING WALL - 0.95 Meter Height

-

-

-

... More
EXCAVATION in foundation in ordinary soil (loam clay or sand ) including lift upto 1.5m lead upto 30.0m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth as directed by the engineer I/C within a lead of 30 m. from foundation trenches.

209.93

152

31909.36

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

153.11

209

32105.64

... More
Cement concrete with 4cm gauge approved stone , ballast approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc- required for proper completion of the work.

11.58

4655

53904.9

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum

45.25

7170

324463.32

... More
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns

21.05

254

5352.8

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

52.62

254

13380.74

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

126.28

552

69815.16

... More
M.S (tor steel or plain) in plain work such as RCC or R.B. work including bending for propoer shape and including supply of steel and its wastage bend, hooks and authorised overlapping shall be measured and including cost of binding wire. Excluding GST

83.35

7530

627678.01

... More
(F) BOUNDARY WALL

-

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :

-

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

169.11

502

84949.03

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

305.87

664

203125.21

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level

39.85

8510

339128.28

... More
Mild steel or iron in plan work shch as reinforced concrete or reinforced brick work(when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend, hooks and authorised overlapping shall be measured and including cost of binding wire. Excluding GST

47.94

7530

361018.4

... More
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineerin- Charge. (The payment of RCC band and reinforcement shall be made for seperately).

71.85

5775

414953.15

... More
M.S or iron work in MS grill & Staircase railling work

58.63

6270

367610.1

... More
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per directionof Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Springcore (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mmwith tape (0.52 mm thick) and weight 43.478 gm/ metre (cost ofM.S. angle, C.C. blocks shall be paid separately)

195.42

250

48997.66

... More
6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)

256.57

208

53610.3

... More
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)

687.3

292

201186.46

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer

943.87

53

50232.76

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :

-

-

-

... More
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

943.87

137

130036.97

... More
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works On steel work

195.42

45

8956.1

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work

195.42

124

24404.05

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

2294.06

53

122571.63

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

326.79

50

16339.5

... More
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: In one coat

50.98

484

24718.67

... More
Same As intem No302(a) above but 1:6 cement & six fine sand (1.25M)mortar Excluding GST

45.38

4845

219866.1

... More
Class-150 brick work in 1:6 cement and COARSE sand mortar in SUPERSTRUCTURE including supply of all materials, labour tools and plants,etc.Required for proper completion of the work.

25.93

5243

135952.29

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm

43.22

3654

157931.07

... More
(G) TOILET AND PRASAD VITRAL STHAL

-

-

-

... More
Cast cement concrete door sills, chaukhats, boundary posts, shelves and similar small work with cement, approved coarse sand and 2 cm. Gauge stone grit in proportions of 1:2:4 excluding cost a reinforcement & its bending but including its fixing and binding the same with 24 B.W.G.G.I. Binding wire and including the cost of binding wire, moulds, all other materials, labour and tool & plant etc. required for propoer completion of the work. The rate excludes making of drip course which shall be paid extra. Excluding GST

1.24

8075

10013

... More
Centring and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Suspended floors, roofs, landing, balconies and access platform.

114.8

632

72664.96

... More
Lintels,beams,plinth beams,girders, bressumer sand cantilevers.

132.88

502

66749.61

... More
Columns,Pillars, Piers, Abutments, Posts and Struts

66.67

664

44274.88

... More
M.S (tor steel or plain) in plain work such as RCC or R.B. work including bending for propoer shape and including supply of steel and its wastage bend, hooks and authorised overlapping shall be measured and including cost of binding wire. Excluding GST Above Plinth

36.61

7530

275696.36

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

7.2

53

384.7

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level

32.24

8510

274366.27

... More
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pitswall trenches basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surroundings of pipes and conduit etc. complete(Plinth area of the building at ground floor only shall be measuredas per I.S. 6313 (Part II 1981) Excluding GST. Aldrine emulsifiable concentrate or any other approved material such as Hepthachlor or chlordance will be used. The rateof applications of chemical emulsion shall be as Follows :-

-

-

-

... More
(1) Treatment for Masonary & foundatiion 5 Liters per Sq.m.

-

-

-

... More
(2) Back fill in immediate contract with foundation 7.5 Litres per Sq.M.

-

-

-

... More
(3) Treatment of Top surface of plinth filling 5 Litres per Sq.M

-

-

-

... More
(4) Treatment junction of walls and the floor 7.50 Litres per Sq.M.

-

-

-

... More
(5) Treatment of soil along External Perimeter of Building 7.50litres per sq.M

-

-

-

... More
(6) Treatment of soil under Apron Along extrnal Perimeter 5 litres per sq.M

114.8

207

23775.08

... More
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

37.53

5775

216745.88

... More
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

1.2

7341

8809.66

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:

-

-

-

... More
Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.

-

-

-

... More
Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs

-

-

-

... More
After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.

-

-

-

... More
Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.

-

-

-

... More
The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge.

-

-

-

... More
With average thickness of 120mm and minimum thickness at khurra as 65 mm.

114.8

1257

144365.59

... More
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, windows sills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite stone slab all colour and texture except black, Cherry/ Ruby red

-

-

-

... More
Area of slab upto 0.50 sqm

2.7

2935

7926.74

... More
Area of slab over 0.50 sqm

4.17

2726

11367.84

... More
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen sink in kitchen platform, vanity counters and similar location in marble / granite/stone work including necessary holes for pillar taps etc. including rubbing and polisheg of cut edges etc. complete.

8

667

5338.48

... More
Approximate cost of Aluminium fitting with screws for door and window including hinges.

5

332

1662.5

... More
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady] the frame.

15.8

580

9166.53

... More
Providing and fixing to existing door frames. 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate onforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.

6.72

3272

21994.16

... More
Providing & Fixing Float glass panes 5.0 mm thick glass panes

1.62

1842

2984.62

... More
M.S or iron work in angle iron door frame including cutting , welding & wastage including supply of all materials , labour T&P etc. required for proper completion of the work Excluding GST

145.47

75

10955.35

... More
Providing and fixing 1mm thk M.S sheet garage door with frame of 40x40x6mm angle iron 3.15mm thick M.S gusset plates at the junction and corners including supply and fixing of necessary fittings, lock rail of 15" lengthof oxidisediron and including pintels hooks at the top and applying a priming coat of red lead paint on all sides complete. exclding GST Using M.S angle 40x40x6mm for diagonal bracings. exclding GST

2.1

2622

5506.2

... More
Providing and fixing quality ceramic glazed wall tiles conforming to IS:15622( thickness to specified by the manufacture)of approved make in all colours , shades excepted burgundy, bottle green,black of any size as approved by Engineer -in-charge in skirting ,risers of steps and dado over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointing with gry cement slurry @ 3.3.Kg per Sqm including pointing in white cement mixed with pigment of matching shade complete.

115.22

878

101176.99

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete

85.75

772

66246.16

... More
Supply and fixing of Kota stone slab flooring over 20 mm (average) thick and jointed with 1:2 cement and coarse sand with approved colouring material to be given and even shade with 12mm base coat ( bedding ) of 1: 2 cement and coarse sand mortar and polished by hand or machine and finishied with french mansor polish or other apprioved polish including supply of all material labour T & p ect required for proper completion of work excluding bases conbcrete . Excluding GST

58.39

1185

69227.18

... More
Supply and fixing 10 to 12mm thick Kota Stone Tiles in skerting of dado laid with 1:2 cement and approved coarse sand mortar finished with in its cement coloured slurry jointing and polishing of approved quality complete including supply of all materials, labour and T&P and etc required for proper completion of the work .Excluding GST.

3.16

1363

4307.87

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase

122.01

214

26213.85

... More
12mm thick cement plaster with cement and sand in proportion 1:6 complete

85.31

137

11751.45

... More
15mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles chamfers and rounded angles not exceeding 80 mm. In girth and finished even and smooth. 1:4 (1 cement: 4 coarse sand)

175.15

292

51269.91

... More
6 mm cement plaster pf mix 1:3 (1 cement : 3 fine sand)

114.8

208

23987.46

... More
Providing & Applying white cement based putty of average thickness of 1mm, of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth including cost of material, labour & T & P etc. complete.

375.27

102

38378.86

... More
Distemper one coat with oil bound distemper of a pproved brand manufacture and required shade on decoreted wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as of Berger, J & N shalimar, asian paints after throughly brushing surface free from mortsr drppings and other foreign matter and also including pre-paring the surface even with paster of paris or synthetic material and sand prepared smooth including cost of all materials. labour T & p As in item No 649 above but for every coat after the first coat.

200.11

97

19580.76

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

175.15

137

24130.42

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work

26.8

108

2908.87

... More
(H) ART WORK

1

1563311

1563311.79

... More
PLUMBING WORK

-

-

-

... More
CHAPTER 1: SANITARY FIXTURES

-

-

-

... More
Providing and fixing 75 mm high, 50 mm deep and 18 mm thick stone slab table rubbed, edges rounded and polished, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade

4

2924

11698.92

... More
Fixing Indian type white glazed earthenware ist quality ISI Marked WC pan size 580mm indian of approved quality.

2

237

475

... More
White glazed earthen ware (Indian type) Neycer W.C. Pan 580 mm Dia

2

522

1045

... More
Fixing of European 'type white glazed earthen ware W.C. pan ( Indian make) of approved 1st quality ISI marked backelite seat cover & lid with C.P. Brasshinges and rubber buffers

4

342

1368

... More
White' glazed earthen ware (European type)W.C. Pan 580 mm. Dia

4

1254

5016

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

4

247

988.72

... More
Fixing wash basin with single hole/number of holes for pillar tap with C.l. Or M.S. brackets painted white including cutting holes and making good the same but excluding fittings size 550x400 mm

5

275

1377.5

... More
Wash hand basin 550x400 mm size of white glazed earthen ware (22”x16")

5

940

4702.5

... More
C P Brass pillar tap 15 mm dia

5

565

2826.25

... More
Providing and fixing toilet paper holder : C.P. brass

4

562

2248.64

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass preaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern.

6

4350

26103.84

... More
Providing and fixing 15 mm PVC connection Heavy quality with brass Union including supply of all materials, labour, T&P etc and required for proper completion of the work. 30 cm length 20mm nominal bore

16

67

1076.8

... More
Fixing brass bib cock I.SI. Marked of 400 gm Weight including supply of all materials, labour, T&P etc. and including threading the pipe if required forproper completion of the work.

2

27

55.1

... More
Brass bib cock heavy quality (Gem Mikado/Encess's Williams or eqv.)

2

223

446.5

... More
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore.

5

584

2924.75

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore

16

413

6610.4

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia

20

86

1723.2

... More
Providing and Fixing 600 mm long Hand rail (Grab bar) for Handicap Toilets with Stainless Steel Screws on wooden cleats complete as per instructions of the engineer-in-charge (As per approved make or equivalent) .

1

1090

1090.6

... More
Providing and fixing soil, waste and vent pipes : 100 mm dia. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

55

876

48196.5

... More
Providing and fixing on wall face uplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with steel ring conforming to IS 5382 leaving 10 mm gap for thermal expansion (i) single socketed pipes. 110 mm dia

33

264

8712.99

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Single pushfit Coupler 110 mm

9.9

91

904.17

... More
Single tee with door 110 x 110 x 110 mm

4.4

169

746.46

... More
Shoe (Plain) 110 mm

4.4

95

421.26

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

4.4

39

174.02

... More
Fixing M.S stays and clamps for sand cast iron pipes of the following diameters

-

-

-

... More
100 mm

11

17

188.1

... More
M S. Holder bat clamp for HCI pipe 100 mm dia

11

71

783.75

... More
Providing and fixing plain bend of required degree. 100 mm dia. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

13.2

285

3771.77

... More
Providing and fixing double equal plain junction of required degree. 100x100x100x100 mm Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

2.2

595

1309.22

... More
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mm dia SS 304 grade coupling with EPDM rubber gasket

49.13

335

16482.62

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

8.8

628

5528.69

... More
Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 100 mm dia

10

508

5084

... More
Fixing of the fotlwing sizes of G.l. Pipe .B. class Jindal /J.TC. make with G.l. Fittings ISI. Marked and clamps including making goodwalls ceilling and floor including supply of all materials, labour, T&P etc. requird for proper completion of the work. Internal work - Exposed on wall 50 mm dia

2.2

62

137.94

... More
Providing G.l. PIPE Class B : 50 mm dia

2.2

299

658.35

... More
Providing and Fixing G.I. Reducing elbow of 100 x 50 mm in cement concrete 1:2:4 at all levels for floor drains (excluding cost of grating) for connection to floor traps in sunken portions, complete as per drawings and as per approval of the engineer-in-charge.(GI Pipe for connecting elbow with floor trap shall be measured seperately )

2.2

516

1136.96

... More
Providing and fixing G.I. Inlet fitting with maximum 3 inlets 32,40 & 50 mm size fabricated from 100 mm dia G.I. pipes and welded G.I. sockets as per site locations, fixed to C.I. Trap and set with proper sealing compound as per drawing complete as per approval of the engineer-in-charge.

8.8

573

5049.44

... More
Providing and fixing cast brass Floor Clean Out plug with suitable insert keys for opening, male threaded joint with G.I. socket drip seal to soil pipe / waste pipe of C.I. pipe as required complete as per drawing, approved sample and direction by Engineer-in-charge: 100 mm dia

2.2

745

1640.65

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall

-

-

-

... More
20 mm nominal outer dia Pipes

36.75

268

9865.17

... More
25 mm nominal outer dia Pipes

49.35

337

16648.22

... More
32 mm nominal outer dia Pipes

5.25

413

2171.66

... More
40 mm nominal outer dia Pipes

5.25

556

2923.36

... More
50 mm nominal outer dia Pipes

34.65

765

26522.84

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):

-

-

-

... More
25 mm nominal bore

3.15

439

1384.68

... More
40 mm nominal bore

1.05

584

613.24

... More
50 mm nominal bore

2.1

725

1522.92

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

1

1413

1413.77

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore

1

329

329.59

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.

4.62

236

1094.29

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m All kinds of soil

-

-

-

... More
Pipes, cables etc, not exceeding 80 mm dia.

25

211

5275.25

... More
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

65

344

22400.3

... More
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre). Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

43.33

104

4544.02

... More
Fixing S.W. gully trap grade MA" complete with C.l Grating bnck masonary chamber & water tight C.l Cover with frame of 300 mm x 300 mm size (inside) square mouth traps of "P" of "S" type traps.

2

137

275.5

... More
S.W. gully trap 150x100mm dia

2

275

551

... More
C.I. cover 300x300mm with frame complete

2

261

522.5

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :

-

-

-

... More
150 mm dia. R.C.C. Pipe

15

407

6107.55

... More
250 mm dia. R.C.C. Pipe

50

669

33489.5

... More
Constructiong manhole with R.C.C top slab in 1:2:4 mix foundation congrete 1:4:3 mix inside plaster 15 mm thick with cement mortar 1:3 (cement and fine sand) with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix finished smooth including cunng and testing. Inside size 1200 mm x 900 mm and 1.0 meter deep including C.l. Cover and frame.

5

1377

6887.5

... More
Extra over item No. SOR - 24.27 for every additional depth of 0.10 metre or part there of main hole Size 1200x900 mm

4

44

178.6

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

10

402

4022.1

... More
Supply, Installation, Testing & Commisioning of Reverse Osmosis unit of following capacity to treat the raw water having TDS 1200 ppm and reducing TDS to 100ppm and hardness less than 50 ppm or as per WHO standards. The operating voltage to 230 volt AC +/- 10%. Potable water system components shall comply with Safe Drinking Water Act Amendments, the 1988 Lead Contamination Control Act and shall be to ANSI/NSF 61 Section 9. Contractor shall require to submit test report post installtion of RO plant and cost shall be inclusive of 15 days training to engineer incharge.

-

-

-

... More
1. Pre and Post treatment Dosing System (each consisting of one HDPE tank of 200 litres capacity with a positive displacement diphragm dosing speed & stroke control pump (1W + 1S) having variable flowrate of 0-6 lph. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary agitator, polypropylene piping, valves, strainers, low level switch(Range 0-600mm) and injection fittings.): a) Biocide dosing system for pre and Hypochlorite and soda ash post dosing and dosage rate 2-3 mg/l. b) Anti scalant dosing system for dosing downstream of MGF and ACF and dosage rate 5 mg/l. c) Acid dosing system in inlet of RO membrane and dosage rate 2 mg/l. d) SMBS dosing system for dechlorination at the inlet of RO membrane and dosage rate 5-10 mg/l. e) PH Correction Dosing system(NaOH) for maintaining the ph to drinking water standard. Dosage required will be 2 mg/l.

-

-

-

... More
2. Filtration System: a)Activated Carbon Filter with initial charge of pebbles, anthracite, media , connecting with multiport valve (for controlling all operations for rinsing, backwashing, service etc under automated system linked with differential pressure transmitter and differential guage), glycerine filled pressure gauge at inlet, outlet and back wash (each with isolation cock), complete as required including wiring and anunciation complete as required with SS 304 piping(paid separately) complete as required and all other accessories required to make the system complete as per the specifications. b) Water softener with brine tank (200 litre HDPE). c) CIP System. d) Raw water feed Pump.

-

-

-

... More
3. Reverse Osmosis System: a) High Pressure Pump(1W+1S): Vertical centrifugal Pump with low pressure switch for smooth operation, dry run protection of adequate capacity and head with SS AISI 304 stage casing, AISI SS 304 impellors, SS Suction chamber, SS 304 Pump shaft, steel base plate, carbon mechanical shaft seal and suction and discharge casing as per IEC standards, connected to TEFC Ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply with glycerin filled pressure gauge , vibration elimination pads, dry run protection etc. complete with base and frame, nuts and bolts. The pump should be rated at the premium efficiency rating of IE. The pump inclosure to be minimum IP 54 rated and insulation class to be F. b) Reverse Osmosis Block comprising of micron filter and membrane encased inside pressure vessels. the membrane to be thin film composite in spiral wound construction. Membrane material to be TFC Polyamide. RO Housing to FRP material with pressure rating of 250 psi. c) Ultraviolet Unit of required flow rate. Capacity: 500 LPH

1

229425

229425

... More
Supply, installation , testing & commissioning of Stainless Steel water tank with inner layer SS316 (0.8mm) + Outer Layer SS 304 (0.6mm) of specified thickness. The tank should be provided with inlet, outlet and vent/overflow connection, 75mm Puf Insulation , cover 450mm dia, Inlet connection of water tank shall be of 25mm nominal bore, overflow/vent - 25mm nominal bore and outlet connection at bottom of tank of 50mm nominal bore. Cost of tank shall be inclusive of Angle stiffeners, stand leg, SS flanges connecting from water treatment facility and distribution system complete as per approved specifications. Capacity: 1000 litre

1

57356

57356.25

... More
Supply, installation , testing & commissioning of high efficiency Storage water cooler / Dispenser of follwing capacities with water at 15°C cooled from 40°C inlet water at 35°C ambient. Evaporator shall be high tank type and shall be encapsulated in insulation. R-404 refrigerant system shall be hermetically sealed and refrigerant shall be capillary tube controlled. An adjustable thermostat having an off position shall control refrigeration system. Cabinet shall be galvanized steel. Potable water system components shall comply with Safe Drinking Water Act Amendments, the 1988 Lead Contamination Control Act and shall be to ANSI/NSF 61 Section 9. chiller should be single phase 220 V, 50 Hz, with cooling coil, heavy gauge galvanized steel complete as required including foundation, complete as required. Cooling capacity : 80 lts/hr. And storage capacity 120 lts

2

63092

126184.7

... More
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate and capacity as below 8 KLD Bio Digester: FRP Bio Digester of 3700L X 2000 WX1250H (in MM.) size of single tank of size 8000 litres tank capacity -x 01 nos with 30% DRDO(Govt of India) approved Anarobic Molecular Inoculums (AMI) to get BOD @ 50-70 mg/ltr good for Gardening purposes

1

1040557

1040557.8

... More
ELECTRICAL WORK

-

-

-

... More
Design, manufacturing, testing at works, supply installation, testing and commissioning of DG Sets of following rating for site conditions (ambient temperature 45 degree C), complete with Diesel Engine, base frame, lube oil system, Radiator, required batteries, governor, instrumentation, exhaust silencers (Hospital type) including Aluminium cladding, alarms, engine mounted control panel, utility piping, anti vibration pads, Alternator direct coupled to Engine along with static excitation system, AVR panel suitable, Acoustic Enclosure and all required accessories complete as required and as per specifications.The scope of work include cabling and earthing. Cable Box to be provided for termination of required Al. Cable.

-

-

-

... More
The DG sets shall be provided with Genset Controller as also mentioned above for AMF/Auto/Manual synchronising, Auto load sharing and having Electrical and Mechanical parameter monitoring, Electrical protection (Under and Over frequency & Voltage, Overload (KW), Over Current, Short Circuit, Excitation failure, AMP Sentry protection.

-

-

-

... More
The cost shall include supply, laying and fixing of suitable sizes of MS B Class piping( Tatas, Jindal (Hissar),IST) with bends etc. for Exhaust of DG Sets including supplying & providing suitable self supporting arrangement etc. and supplying & fixing 75 mm thick mineral wool insulation of 150 Kg per cubic meter density on all sides of Exhaust pipe and silencer with chicken mesh wrapping and aluminium cladding with aluminium sheet of 26 SWG,suitable for outdoor installation complete as required and as per specification. (Refer Layout enclosed) . The rate shall include complete supplying, installation, testing and commissioning rates including cost of CC foundation as per OEM requirements and site conditions, POL/fuel for testing purposes as per CPWD specifications, and all tools and accessories required to Complete the job in full respect. Note :- The rates shall include guide support, expansion joints & SS bellows for Exhaust piping wherever required. The DG Exhaust shall be taken to required height as per CPCB and scope includes building required structure for reaching up to the required height. Any other standard accessories, metering, protections etc as per CPWD specifications 140 KVA

1

1059943

1059943.5

... More
Supply and installation of 990 litres Fuel tank alongwith required piping & valves complete as required.

1

32119

32119.5

... More
Design, manufacture, testing at works, supply, installation testing & commissioning of following floor / wall mounted clad switchboard, factory built, modular, sectionalised, dead front, fully compartmentalized with hinged lockable detachable front & back openable, Form IIIB type extensible Partial Type Tested Assembly, IEC-60439 compliant LT cubicle panel of suitable size, suitable for operation on 433 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from powder coated CRCA sheet steel, with all load bearing members of minimum 2mm thickness , all non-load bearing members of minimum 1.6mm thickness and minimum 3mm thick gland plates. The panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition, having vibration free structure with stiffeners provided as required.

-

-

-

... More
Note - The following minimal characterstics shall be considered for each panel :

-

-

-

... More
Operating Voltage - 433 Volts

-

-

-

... More
Frequency - 50 Hz (+/- 3%)

-

-

-

... More
IP 43 for Indoor Panels & IP 55 for Outdoor Panels

-

-

-

... More
Pollution Degree - 3

-

-

-

... More
Ambient Temperature - 45 Degree Celsius

-

-

-

... More
Annual Average Relative Humidity - 50%

-

-

-

... More
An approval shall be taken for each panel before manufacturing.

-

-

-

... More
The Switchboards shall have provision to accommodate all cables from the bottom /top as required.

-

-

-

... More
All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB door handle shall be interlocked and lockable in OFF position.

-

-

-

... More
Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards.

-

-

-

... More
The bottom base ISMC channel of suitable section but not less than 75mm x 50mm x 5mm shall be used.

-

-

-

... More
Each panel shall have a suitable aluminium earth bus but not less than 25mm x 6mm throughout the length of switchboards at the rear with 2 nos. earth studs on either sides of panel board for connecting earthing strips. (Except Main Isolation panel where earth bus shall be 50mmx10mm)

-

-

-

... More
The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used.

-

-

-

... More
Control wiring shall be done with 1.1kV grade FRLS type control cables tested for power frequency withstand of 2kV AC Current Circuit -2.5 sq. mm. AC Voltage Circuit-1.5 sq. mm. Other Aux. AC Circuit-1.5 sq. mm. DC Circuit-2.5 sq. mm.-Main Circuit, 1.5 sq. mm. Aux Circuit Earth Wire Circuit-2.5 sq.mm.

-

-

-

... More
Suitable Aluminium earth bus to be provided throughout the length of Switchboards.

-

-

-

... More
All indication lamps / illuminated push buttons shall be LED type.

-

-

-

... More
2A/6A SP MCBs shall be used as backup protections.

-

-

-

... More
All MCCBs shall be provided at least with ON, OFF & Trip indication lamps unless otherwise specified.

-

-

-

... More
All MCCBs shall be with thermal magnetic releases up to 160 A rating and with microprocessor based releases above 160 A rating, line load reversibility, Ics = 100% Icu, & extended rotary handle unless otherwise specified

-

-

-

... More
All micrprocessor based MCCBs shall have inbuilt earth fault protection with trip history i.e Faulty phase, Type of Fault and interrupted current and all thermal magnetic based MCCBs shall be provided earth fault protection through E/F module having separate indication of overcurrent & earth fault on panel door.

-

-

-

... More
All MCCB shall have rotary handle with pad locking arrangement. The MCCBs shall be lockable in OFF position.

-

-

-

... More
Door interlocking for all feeders shall be provided.

-

-

-

... More
All TP MCCB'S shall have solid neutral link,disconnect type.

-

-

-

... More
The MCCBs shall have single frame size upto maximum rating available with OEM to reduce the requirement of spares management.

-

-

-

... More
All breaking Capacity for MCCB to be Ics=100%Icu and Uimp of 8KV.

-

-

-

... More
All control & power wiring from all components such as switchgears, meters, relays etc. shall be broughtout upto the terminal blocks inside cable alley.

-

-

-

... More
All outgoing terminals shall be provided in cable alley on proper insulated supports (SMC/DMC).

-

-

-

... More
Any panel which has almirah type doors at back side shall be provided with lockable arrangement.

-

-

-

... More
Space heater shall be provided with thermostat with 6A MCB as backup protection inside all cable alleys controlled with feeder 20 A DP MCB 10 KA.

-

-

-

... More
Provision of one 6/16 amp socket & compartment lighting for each vertical section of main Main Isolation Panel.

-

-

-

... More
All MCB to be C Curve for raw power and D curve for UPS power.

-

-

-

... More
Removable lifting hook shall be provided in all transportation section.

-

-

-

... More
Multifunction meters installed shall be BMS Compatible, capable of delivering Bacnet, Modbus or Lonworks protocol etc.

-

-

-

... More
Bus bar shall be high conductivity (99%), ETP - Electrical grade copper or 50-55% Aluminium as specified in BOQ.

-

-

-

... More
Bus bar shall be designed on 45 deg. Ambient temperature and limit of temperature rise shall be 35 deg. Over and above Ambient temperature.

-

-

-

... More
Bus bars shall be with heat shrinkable PVC sleeves.

-

-

-

... More
MCB's shall be of minimum 10kA fault with stand capacity.

-

-

-

... More
Illuminated push button on Starter Panels of Pumps.

-

-

-

... More
Interlocking / Auto start command terminals for starter Panels.

-

-

-

... More
Concerning vendor needs to furnish the busbar calculations (for both phase and earth bus) at the time of GA approval and busbar size has to be as per the approved GA drawing.

-

-

-

... More
Provision for accommodating incoming and outgoing cables adequately shall be as per single line diagram for each panel.

-

-

-

... More
The starter shall comprise of all necessary power and control equipments including Auto / Manual selector switch, illuminated Start/stop push butons, LED indications, Star contactor , delta contactor , timer relay contactor, electronic timer, potential free NO/NC contacts and necessary control wirings properly connected in fully usable state.

-

-

-

... More
Interlocking / Auto start command terminals for starter Panels.

-

-

-

... More
Minimum utilization catagory for all contactors shall be AC3 and contactor shall be capable to withstand the steady state (full load) and starting inrush current.

-

-

-

... More
The starter shall have necessary protection device (MPCB+EOCR) whose settings and ratings shall be as per the type-2 co-ordination chart.

-

-

-

... More
The starter shall have inbuilt protection against overcurrent, short circuit and single phasing.

-

-

-

... More
All these starters shall be equipped with discharge resistors suitable for making the starter run under the closed transition state.

-

-

-

... More
All below mentioned starters shall be BMS compatible and additional contacts and wiring required for BMS integration shall be provided.

-

-

-

... More
The starter component selection shall stricly be as per respective OEMs Type-II selection criteria.

-

-

-

... More
For MCCB-Temperature deration: No deration up to 50 degree Celsius (In case deration is applicable, higher rating switchgear shall be provided)

-

-

-

... More
MAIN ISOLATION PANEL

1

1853238

1853238.15

... More
Main Incomer (From CSS) 1 x R,Y,B LED indication lamp with 2A control MCB 1 x ON,OFF,Trip LED indication lamp with 2A control MCB. 1 x Class 1&2 surge arrester with suitable protection. 1 x 400 A, FP, 16kA, MP Based MCCB with LSIG protection. 1 x 400A FP heavy duty power contactor connected as shown 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH KW, KWH, KVAR, PF, V, A, Hz with 3X400/5A, 5VA Class 1.0 CTs) 400/5A, 15VA, CL-1 current transformer at MCCB incomer & APFC realy sensing. - 1 Nos. 400/1A, 15VA, CL-PS current transformer for REF protection of transformer - 4 Nos.

-

-

-

... More
Incomer (From DG AMF) 1 x R,Y,B LED indication lamp with 2A control MCB 1 x ON,OFF,Trip LED indication lamp with 2A control MCB. 1 x Class 1&2 surge arrester with suitable protection. 1 x 250 A, FP, 16kA, MP Based MCCB with LSIG protection. 1 x 250A FP heavy duty power contactor connected as shown 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH KW, KWH, KVAR, PF, V, A, Hz with 3X250/5A, 10VA Class 1.0 CTs) 250/5A, 15VA, CL-PS current transformer for REF protection of transformer - 4 Nos. Selector type auto / manual switch -1 Nos. 230 volt, 50Hz,AC operated Hooter with noise level of 80db at every 3 metres with acknowledge and reset push button-1 Nos. 8-window microprocessor based annunciation panel with visual LED indicator complete as per specifications and schedule as required. - 1 Nos. DG START STOP PUSH BUTTON -1SET Emergency Stop Button-1No

-

-

-

... More
Busbar (1 Set - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable to carry 415V, 50 Hz, 300 A, 16kA for 1 sec of required length and cross sectional area. Note : Concerning vendor needs to furnish the busbar calculations (for both phase and earth bus) at the time of GA approval and busbar size has to be as per the approved GA drawing.

-

-

-

... More
Buscoupler : 1 x 250 A, FP, 16kA, MCCB with microprocessor based release with inbuilt LSIG protection,with 1 x 250A 4P heavy duty power contactor connected as shown. connected as shown. Required Interlocking between other incomer & Bus Coupler to be provided as per Interlocking shown in Single Line diagram.

-

-

-

... More
Outgoings: 11 x 63 A, FP, 16kA MCCB with MP based release with LSIG protection. 6 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of at least KVARH KW, KWH/KVAH, KVAR, PF, V, A, Hz with 60/5A 5VA Class 1.0 CTs) Indication lamps LED type Indication lamps for breaker, suitable for 230V,50Hz AC supply (on, off, trip) - 6sets 1 x R,Y,B LED indication lamp with 6A control MCB.-11sets.

-

-

-

... More
Micro PLC for Auto Load Management as per Logic mentioned in Single Line Diagram, comprising required Auxiliary relays (24V DC, indication lights, Push button, Emergency stop, A/M position switch, Battery charger (230V A/C / 24V DC), Batteries, Digital I/O card, analogue card, 24V DC power supply as required.

-

-

-

... More
The AMF operation of DG Sets shall be carried out by controller installed on each DG Set by DG Manufacturer however required coordination and provisions to achieve the same in coordination with PLC based Auto Load Management is included in the scope of work of Panel Manufacturer.

-

-

-

... More
External Lighting Fedder Pillar Panel -1 & 2- (Outdoor Type) -IP-55 double door distribution board totally enclosed complete with suitable RCC pedestal.

2

143391

286782.2

... More
Main Incoming - 1 no. each having as follows:-

-

-

-

... More
1 nos. 63A FP MCCB 16kA, MCCB with thermal magnetic based release with earth fault protection through E/F module.

-

-

-

... More
Indication lamps LED type phase indication lamps suitable for 230V,50Hz AC with suitable control MCB (red, yellow, blue) - 1 set. LED type Indication lamps for breaker, suitable for 230V,50Hz AC supply (on, off, trip) - 1 set.

-

-

-

... More
Metering Multifunction meter with inbuilt selector switch for measurement of current, voltage, power factor, KVA, kVAh, KVArh, KVAR, frequency, %THD (upto 15th order), THDi,THDv,KWHr (both line and phase) and maximum demand recording and indicating etc. complete as per specifications,along with RS485 port along with 3Nos. , 415V ,60/5A, 5VA, CL-1 current transformer complete as required - 1 Set

-

-

-

... More
Sub Incoming - 1 no. each having as follows:-

-

-

-

... More
40A FP MCB, 10 KA breaking capacity ,"C" type

-

-

-

... More
1 Set. Astronomical Time switch programmeable type (0-24) hour with NO and NC contact setting and Automatic selector switch.

-

-

-

... More
1 Nos. 40 A TP motor duty contactor with NO-NC contact and 230 V A.C coil.

-

-

-

... More
Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable to carry 415V, 50 Hz, for below rating of required length and cross sectional area.

-

-

-

... More
1 Lot of 63A TPN Aluminium bus bars.16kA for 1 sec

-

-

-

... More
1 Lot of 40A TPN Aluminium bus bars.10kA for 1 sec

-

-

-

... More
Outgoing

-

-

-

... More
First Bus Outgoing 2X40A DP MCB 10 KA breaking capacity ,"C" type 3X40A FP MCB 10 KA breaking capacity ,"C" type Second Bus Outgoing 7 x16 Amp, 100mA, DP RCBO 5 x16 Amp, 100mA, DP RCBO 2 x20 Amp, 100mA, DP RCBO

-

-

-

... More
Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, minimum load power factor 0.8,power factor 0.99, having OVCD (over voltage cut-off device), having CVCF (constant voltage constant frequency, bypass parameters configurable, 2 stage charging(constant current/float charge), having temperature compensated charger, Fan speed control, digital signal processor controller, total harmonic distortion (current)-THDi (10%@50% R Load, Input 1 phase voltage 230v, voltage range 110-300v, Output voltage (220AC/230AC/240AC ± 1%), Total harmonic distortion Voltage (THDv- 3% linear load, 5% nonlinear load, 90 % AC/AC efficiency, Over load capacity(105-110%: 3min, 111-130%: 30Sec), operating temperature with full load 0-40°C, communication features (RS232, USB com port, Intelligent slot(optional). UPS installation with all required material arrangements as required as per IS specification.

-

-

-

... More
5 KVA (1 phase input & 1 phase output) For 30 minute backup, min. 4000 VAH

1

158374

158374.5

... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.

-

-

-

... More
6 sq. mm 2 core

150

262

39330

... More
6 sq. mm 3 core

30

269

8094

... More
4 sq. mm 4 core

120

268

32262

... More
6 sq. mm 4 core

90

282

25393.5

... More
10 sq. mm 4 core

100

310

31065

... More
16 sq. mm 4 core

100

325

32585

... More
35 sq. mm 3-1/2 core

100

400

40090

... More
185 sq. mm 3-1/2 core

30

1083

32490

... More
240 sq. mm 3-1/2 core

30

1310

39301.5

... More
Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge.

-

-

-

... More
6 sq. mm 2 core

20

72

1444

... More
6 sq. mm 3 core

4

72

288.8

... More
4 sq. mm 4 core

16

72

1155.2

... More
6 sq. mm 4 core

6

76

456

... More
10 sq. mm 4 core

4

82

330.6

... More
16 sq. mm 4 core

2

82

165.3

... More
185 sq. mm 3-1/2 core

2

377

754.3

... More
240 sq. mm 3-1/2 core

4

449

1797.4

... More
Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required.

-

-

-

... More
2C X 2.5 sqmm copper conductor

50

130

6507.5

... More
4C X 2.5 sqmm copper conductor

50

201

10070

... More
6C X 2.5 sqmm copper conductor

50

285

14297.5

... More
10C X 2.5 sqmm copper conductor

50

424

21232.5

... More
Supplying and making end termination with single compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required.

-

-

-

... More
2C X 2.5 sqmm copper conductor

8

143

1147.6

... More
4C X 2.5 sqmm copper conductor

4

172

691.6

... More
6C X 2.5 sqmm copper conductor

4

229

919.6

... More
10C X 2.5 sqmm copper conductor

2

286

573.8

... More
CHAPTER 5: CABLES MANAGEMENT

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width x 50 mm depth x 1.6 mm thickness

10

498

4989.5

... More
150 mm width x 50 mm depth x 1.6 mm thickness

10

536

5364.3

... More
300 mm width x 50 mm depth x 1.6 mm thickness

10

728

7288.5

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

1

885

885.44

... More
150 mm width X 50 mm depth X 1.6 mm thickness

1

972

972.91

... More
300 mm width X 50 mm depth X 1.6 mm thickness

1

1426

1426.87

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

1

1016

1016.22

... More
150 mm width X 50 mm depth X 1.6 mm thickness

1

1061

1061.2

... More
300 mm width X 50 mm depth X 1.6 mm thickness

1

1663

1663.44

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

1

1016

1016.22

... More
150 mm width X 50 mm depth X 1.6 mm thickness

1

1061

1061.2

... More
300 mm width X 50 mm depth X 1.6 mm thickness

1

1827

1827.53

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

1

1272

1272.78

... More
150 mm width X 50 mm depth X 1.6 mm thickness

1

1481

1481.02

... More
300 mm width X 50 mm depth X 1.6 mm thickness

1

2180

2180.71

... More
Note : The bidder shall consider variation in colors of powder coating as per interior designer while quoting. No extra cost shall be payable in case of change in color of cable trays or raceways.

-

-

-

... More
S & F surface/Flush mounting 6ways TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. CAT A

2

4151

8303

... More
S & F surface/Flush mounting 8ways TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. CAT A

1

4949

4949.5

... More
S & F surface/Flush mounting 12ways V TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. CAT A

1

12958

12958

... More
Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

1

636

636.39

... More
S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. CAT A

64

247

15808

... More
S&F of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve. CAT A

2

703

1406

... More
S&F of 6 Amp. to 32 Amp. TP MCB (10 KA) C Curve . CAT A

5

1130

5652.5

... More
S&F of 40 Amp. TP MCB (10 KA) C Curve

5

1691

8455

... More
S&F and making connection of 25A 2 pole 30mA ELCB/ RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge.

3

2156

6469.5

... More
S&F and making connection of 40A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge.

11

2166

23826

... More
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

1407

7038.6

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

1026

5131.1

... More
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and

-

-

-

... More
For 6 way, Double door FP MCBDB

2

1491

2983

... More
For 8 way, Double door FP MCBDB

1

1549

1549.45

... More
Supplying and fixing Cable End Box (Loose wire box)(IP 43)suitable for 12 way, Double door SPN MCB DB single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required.

2

3097

6195.9

... More
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.

-

-

-

... More
S&F of 40 Amp. 4 pole MCB (10 KA) CAT-A

3

2161

6483.75

... More
S&F of 63 Amp. 4 pole MCB(10 KA) C Curve. CAT-A

1

2175

2175.5

... More
Wiring point for light with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earth wire drawn inside. GP Box, Modular type switch & ceiling rose/angle/ batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect.

45

621

27958.5

... More
Wiring point for two way light with 1.5 Sq. mm F.R. PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earth wire drawn inside. GP Box, Modular type switches & ceiling rose/angle /batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect.

5

908

4541

... More
Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earth wire drawn inside. GP Box, Modular type switch & ceiling rose on 3 mm. thick backelite sheet etc. complete in all respect

9

679

6113.25

... More
Wiring point for plug with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earth wire drawn inside. GP Box, Modular type switch & socket etc. complete in all respect.

23

389

8958.5

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

33

462

15255.9

... More
Supply & wiring of submains with two number 4 sq.mm FRLSH PVC insulated 1100 Volt grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit with one no. 2.5 sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. complete in all respect.

119

141

16844.45

... More
Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.

16

323

5168

... More
Supply & wiring of submains with 4 number 6 sq.mm FRLSH PVC insulated 1100 Volt grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2 mm thick) PVC conduit with 2 nos. 4 sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. complete in all respect.

175

342

59850

... More
Supply & wiring of submains with two number 10 sq.mm FRLSH PVC insulated 1100 Volt grade multistrand single core copper conductor cable in 25 mm dia heavy duty (2 mm thick) PVC conduit with one no. 6 sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. complete in all respect.

175

258

45220

... More
Supply and fixing of G.P. Modular switch box for 1 / 2 Module of approved make made up of 1.0 mm thick ISI Marked G.P.sheet including adjestable Nakka and holes plugged with PVC Nylon Caps . Two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box. Holes should be semi-shuttered type and fitted with heavy brass Earth Piller duly screwed & brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge.

-

-

-

... More
Same as in item no 1152 (A) but for 3 Module

15

114

1710

... More
Same as in item no 1152 (A) but for 4 Module

10

123

1235

... More
Same as in item no 1152 (A) but for 6 Module

15

166

2493.75

... More
Same as in item no 1152 (A) but for 8 Module

10

190

1900

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required

-

-

-

... More
Telephone or DATA socket outlet

6

62

374.82

... More
TV antenna socket outlet

2

63

126.62

... More
Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.

11

142

1567.5

... More
Supply and fixing of electronic fan regulator( Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T & P etc. for proper completion of work to the satisfaction of Engineer in charge of work.

11

491

5402.65

... More
Installation of exhaust fan in the existing opening , including making good the damage, connection, testing commissioning etc. as required.

-

-

-

... More
(a): Up to 450mm sweep

9

302

2721.33

... More
Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes.

9

139

1259.46

... More
Erection and testing of ceiling fan and regulator for room height upto 3.5 metres including supply of 3mm thick G.I.Pipe19mm dia. Duly painted, complete in all respect.

11

133

1463

... More
Supply and fixing of fan hook fabricated from M.S. rod for ceiling fan each.

11

128

1410.75

... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.

-

-

-

... More
100 mm X 100 mm X 60 mm deep ( for TV)

2

133

266.54

... More
200 mm X 250 mm X 60 mm deep ( junction of tel data )

6

279

1674.24

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in surface recess steel/PVc conduit as required

90

27

2474.1

... More
Supply and fixing and concealing of 20 mm dia. 16 SWG (1.5 mm.) thick rigid steel conduit pipe in the wall including cutting of brick work, laying of conduit and fixing it with M.S. hooks and then plastering with cement, sand mortar finished to the level, with matching colour wash including cost of proper threading of the conduit & providing necessary socket, bends and chuck nuts and as directed by the Engineer in charge with the supply of all material labour and T&P required for proper completion of work. Same as in item 148, but 32 mm dia 16 SWG (1.5 mm) thick rigid steel conduit.

350

207

72485

... More
Supply and fixing and concealing of 20 mm dia. 2mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge.

100

58

5890

... More
Same as in item 148 (A) but 25 mm dia 2 mm thick PVC conduit.

239.2

68

16361.28

... More
Same as in item 148 (A) but 32 mm dia. PVC conduit.

125

82

10331.25

... More
Supply and wiring of submain with two number 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit with 1 nos. 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduite complete in all respect including matching colour wash.

226

99

22543.5

... More
Wiring point for H.P.M.V. Sodium Vapour lamp with 1.5 Sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earth wire drawn inside. GP Box, 15 Amp Modular type switch etc. complete in all respects.

4

142

570

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

32

49

1599.36

... More
Supplying and fixing following weatherproof IP65, IK09 thermoplastic self-extinguishing modular box with flap to accommodate modular switches and sockets base & cover plate complete as required. 100 mm X 75 mm X 60 mm deep (3 Module)

10

745

7457.5

... More
Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.

10

9538

95380

... More
Supply and burring of Safe Earthing Electrode T-19 Cu Copper Coated, Length 3000mm, outer pipe 48.4mm x 3.2mm, inner pipe 26.9mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 Copper Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.

6

14326

85956

... More
Supply and burying earth electrode for lighting conductor of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe for watering funnel, 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer in-charge complete in all respect.

6

4417

26505

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

60

47

2848.8

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface, cable tray or in recess for connections etc. as required.

144

171

24708.96

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

36

402

14483.52

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

64

1019

65251.2

... More
Providing and fixing 25 mm X 5 mm tinned copper strip on surface, cable tray or in recess for connections etc. as required.

16

840

13447.36

... More
Supply and fixing of vertical air termination final rod comprising of 300mm long x 25mm dia. Copper rod with one pointed prong and 100mm dia x 3 mm thick base plate etc. complete in all respect. As in item 712(A) but with G.I. Material

6

541

3249

... More
Supply and fixing of horizontal air termination (roof conductor) of 25mm x 3mm G.I. strip, G.I. clamps on surface complete in all respects as approved by Engineer in-charge

140

161

22610

... More
Supply and fixing of testing joint of G.I. strip 32mm x 6mm and 150mm long with G.I. bolts and nut etc.complete in all respect.

6

61

370.5

... More
Supply, Installation, Testing and Commissioning of following Points inside the building. All the below mentioned points shall be wired as per the described scheme and with 1.1kV grade, FRLS type of Cu. The primary shall mean the first light point connected to switch and secondary means rest all points looped with the said primary. The said wires shall have stranded conductors and proper gauge. The rate shall include complete Supply, Installation, Testing and Commissioning rates including cost of conceled PVC conduit in slab along with the cost of electronic drivers, ballasts, capacitors, ignitors, ceiling rose / connectors / angle holders , lugs and all tools and accessories required to as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge.

-

-

-

... More
Supply, installation, testing and commissioning of Specially designed spot light with glare cut visor 230-240Vac CRI 80 MacAdam step 3Input power : 30W Dimension Ø166 x 153 x 423mm, Light Distribution Symmetrical along with inbuilt Electronic driver , IP rating must be IP65 or higher, Made out of Extruded aluminium bottom ribbed pipe (grade 6063 with test certificate) Ø166 x 3mm thickness & Die cast aluminium housing (grade ADC12 with test certificate). SS fasteners. Die-cast aluminium mounting plate Ø100.5 x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD 55 with pure polyester powder coating. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foudation. Hot dip galvanised foundation bolt. Mechanical resistance IK07. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. Optical grade clear polycarbonate lens. Lamp fixed position. Should have minimum luminous flux of 90-100 lumens/Watt. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency 85%, power factor 0.9, THD 10%, Surge protection 4KV. Manufacturer must have inhouse shot blasting machine and NABL certified lab equipped with photo goniometer, IP, IK test facilities , the fixtures proposed must have passed LM 79 & LM-80, latest Reports will be submitted post the issuance of LOA to the successful bidder and before the supply of material CE & BIS Certified.

30

16055

481650

... More
Supply, installation, testing and commissioning of Square shaped UP-DOWN 2X6W. Dimension 150 x 100 x 270mm, Wall-mounted compact updown light, emission designed to use monochromatic Warm white (3000K) & Neutral white (4000K). Should be equipped with Hybrid optics with lens & mirror finish pure aluminum reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Extruded aluminum section with inner grooves to fix the top and bottom frame (grade 6063) Sq100 x 3mm thickness, die-cast aluminum glass fixing top and bottom frame Sq100mm (ADC12) with clear toughened glass diffuser of 4mm thickness with ceramic black coated on outer corner siliconed to frame. Die-cast aluminum heat sink for excellent thermal management. Single cable entrance via black PG7 cable gland, Die cast aluminum base for surface mounting on wall (ADC12). All external screws are made of stainless steel. Clear silicone gasket. Protection class IP65. Mechanical resistance IK07. Acid treatment & pure polyester powder coated graphite grey/ anthracite grey/ jet black. The luminaire's built-in LED module are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21). Operating ambient temperature range is from -15°C to +50°C. Beam angle 15°/ 25°/ 40°, Colour rendering index (CRI)80. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency 85%, Power factor 0.95, THD 10%, Surge protection 4KV. Luminaire dimension: 150 x 100 x 270mm.IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. Certification: CE Certified, Design Patented/ Registered, ROHS compliant, BIS Certification for Luminaires & Drivers.

51

10741

547824.15

... More
Supply installation testing & commisioning of Static White 3000K 12W In-ground with in built honey comb louvre symmetrical luminaire made up of die-casting with Ø173 x 220mm,the Ø173 front ring should be made up of stainless steel 316 grade front ring with silicone black gasket and toughened clear glass diffuser. The luminous flux of the luminaire is upto 900-950 lm for 3000K BEAM - 15°/25°/40. The ingress protection is IP67 and impact resistance of IK09 . The luminaire is integrated with high power CITIZEN COB with CRI≥80, SDCM≤3, L70/ B10 @ 60000 Hrs. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 2KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100-277Vac and operating temperature of -20˚ ~ +40˚C.Adequate heat sink with proper thermal management shall be provided. Operating Humidity : 10%-90%. THD should be less than 10%. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. CE & BIS Certified.

11

34865

383525.45

... More
Supply installation testing & commisioning of surface mounted 10W/meter IP67 modular profiles with translucent polyurethane encapsulation integrated with LED’s. Luminaire body made of extruded aluminium with IP67 connector on both ends. Fixture should have CRI80, CCT 3000K. The LED’s in fixture should have minimum usable life of 60,000 burning hours L80B10 and SDCM =3. Fixture should have minimum impact resistance of IK10

42

21298

894518.1

... More
Supply installation testing & commisioning of Static White 3000K, Should be rectangular compact and robust wall recessed luminaires for illuminating walls and stairs. Must be forward asymmetrical light distribution. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. ABS plastic installation housing for preparing the recess opening in wall / stairs. Clear acrylic diffuser. Single cable entrance via M10 cable gland. Protection class at least IP65 or higher. Mechanical resistance IK09. Pure polyester powder coated graphite grey / anthracite grey / jet black.Power consumption should be between 10W to 12W at steady state full intensity luminaire should have minimum luminous flux  of 743Lm, should be available in different colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 130mm length x 87mm width x 76mm height. Luminaire installation in a recessed opening cut-out dimension : 240mm length x 83mm width x 70mm height. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. CE & BIS Certified.

90

6558

590292

... More
Supply installation testing & commisioning of Static White 3000K, Should be rectangular compact and robust wall recessed luminaires for illuminating walls and stairs. Must be forward asymmetrical light distribution. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. ABS plastic installation housing for preparing the recess opening in wall / stairs. Clear acrylic diffuser. Single cable entrance via M10 cable gland. Protection class at least IP65 or higher. Mechanical resistance IK09. Pure polyester powder coated graphite grey / anthracite grey / jet black.Power consumption should be between 6W-8W steady state full intensity luminaire should have minimum luminous flux  of 743Lm, should be available in different colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 130mm length x 87mm width x 76mm height. Luminaire installation in a recessed opening cut-out dimension : 240mm length x 83mm width x 70mm height. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. CE & BIS Certified.

23

5017

115411.7

... More
Supply installation testing & commisioning of Static White 3000K surface mounted compact spot light designed to provide directional light. Beam angle 15°/ 25°/ 40°. Luminaire made of pressure die cast aluminum alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminum reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Power consumption should be between 5W to 6W at steady state full intensity luminaire should have minimum luminous flux of 300 Lm. Color rendering index CRI ≥ 80 and power factor of complete luminaire ≥ 0.90, at white colour. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP65. Mechanical resistance IK06. Pure polyester powder coated graphite grey/ anthracite grey/ jet black. Available colour temperature 3000K/ 4000K, Colour rendering index (CRI)80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension: 101mm length x 64mm width x 93mm height. Adequate heat sink with proper thermal management shall be provided. Operating Temperature: -10°C to +50°C, Operating Humidity: 10%-90%. THD should be less than 10%. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. CE & BIS Certified.

63

8720

549363.15

... More
Supply installation testing & commisioning of Static White 3000K surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression.Power consumption should be between 6W at steady state full intensity luminaire should have minimum luminous flux  of 458 Lm. Color rendering  index  CRI  ≥  80  and power  factor  of complete luminaire ≥ 0.90, at white colour. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP65/66. Mechanical resistance IK05. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)80. SDCM-3 MacAdam. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire 101 x 90 x 330mm.Adequate heat sink with proper thermal management shall be provided. Operating   Temperature   : -10°C   to   +50°C,   Operating Humidity : 10%-90%. THD should be less than 10%.. The fixtures proposed must have passed LM 79 & LM-80, Reports from inhouse NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material.

53

6826

361815.1

... More
Supply installation testing & commisioning of 2 x 18W & 50W LED square decorative leser cut designer column LED 3000K, 4000K, 6500K 230-240Vac CRI 80 MacAdam step-3 Height 4000mm Light Distribution Symmetrical, Electronic driver ON/OFF LUMINAIRE TYPE Bollard. IP rating IP65, Extruded square aluminium tube (grade 6063 with test certificate) Sq. 150 x 3mm thickness. Should have Bespoke laser cutting design options with 1400mm length. SS fasteners. Must be equipped with Pre treated epdm black gaskets. Should have Die-cast aluminium mounting plate Sq.300 x 16mm thick 4 Elongated holes 48 x 24 to suit M20 bolts at CC 215 with pure polyester powder coating. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foudation. Hot dip galvanised foundation bolt. Mechanical resistance IK06. It should be Pure polyester powder coated process : Acid treatment & pure polyester powder coating. Optical grade clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Lamp fixed position.This luminaire should contains built-in IP 65 LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency 85%, power factor 0.9, THD 10%, Surge protection 6KV.Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities.

32

137655

4404960

... More
Supply installation testing & commisioning of 24W Linear Wall Washer LED 3000K, 4000K, 6000K 24Vdc CRI 80 MacAdam step 3 Dimension : 1000 x 35 x 78 mm Beam angle : 30° / 15°x60°, Electronic romote driver ON/OFF, Surface Mounted luminaire. IP rating IP65, Extruded aluminium alloy housing (grade 6063). Toughened clear glass diffuser. SS fasteners. Mechanical resistance IK06. Aluminium mounting bracket for surface mounting on ground. Toughened Clear glass diffuser and optical to reduce glare controlled. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire 60,000 hours at 40°C with delivered lumen of 2400lm. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency 85%, power factor 0.90, Surge protection 3KV. CE and BIS.

11

12606

138671.5

... More
Supplying, installation, testing & commissioning of wall mounting fan with all accesories, including 3 core 1.5 sq.mm FRLS PVC insulated and PVC sheathed copper conductor cable and earthing etc. upto suitable point complete as required.

11

3093

34025.2

... More
Supply of BEE 5star rated following ceiling fan, including wiring, the down rods of standard length (upto 30 cm) with 3x1.5 sqmm FRLS PVC insulated copper conductor single core cables etc., as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 1200 mm sweep ceiling fan

11

4674

51414

... More
Supply of 300mm size exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge.

9

2831

25479

... More
Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser / Reflector and driver set complete in all respect. CAT- AAA

12

1282

15390

... More
Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA

27

1776

47965.5

... More
Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA

10

1130

11305

... More
Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR 2 Megapixel fixed Dome Camera, lens - 2.8mm/3.6mm/6.0mm , 1/3” CMOS image sensor, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, 3D NR, HLC, BLC, Privacy Mask, 3 IR LEDs Smart IR with upto 30m IR distance, ONVIF Profile S & Profile G compliant,IP66, IK10, PoE, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

5

8030

40151.75

... More
Supply, Installation, Testing & Commissioning of 4MP Bullet fixed camera , 1/3" CMOS image sensor , IR distance: 80 m ,; 6 mm; 8 mm,RoI, SMART H.264+/H.265+, flexible coding, applicable to various bandwidth and storage environments , Rotation mode, WDR, 3D NR, HLC, BLC, digital watermarking ,ntelligent detection: Intrusion, tripwire , Motion detection, video tampering, no SD card , SD card full, SD card error, network disconnection, IP conflict, illegal access, local alarm, voltage detection,audio detection ,Alarm: 1 in, 1 out; audio: 1 in, 1 out; supports max. 256 GB Micro SD card ,IP67 protection, IK10 protection , Certifications -UL ,CE ,FCC including all accessories complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

25

17207

430183.75

... More
Supply, Installation, Testing & Commissioning of Image Sensor 1/3” 2 Megapixel Varifocal Bullet Camera progressive CMOS, Illumination Distance 60 m , Lens Type Motorized vari-focal, Focal Length 2.7 mm–13.5 mm , IVS Tripwire; intrusion , Smart Codec Smart H.265+/ Smart H.264+ , BLC ,HLC , WDR 120 DB , Alarm Event - No SD card; SD card full; SD card error; network disconnection; IP conflict; motion detection; video tampering; tripwire; intrusion; illegal access; voltage detection; safety exception.

5

11471

57356.25

... More
Supply , Installation , Testing and commissioning  of 32 Channel NVR (Network Video Recorder), for recording upto 32CH @ 1080P with 08 nos. SATA HDDs minimum 10TB storage or more (recording requirement all cameras recording at 2MP, 25fps for 60 days), H.265 / H.264 / MJPEG/ MPEG4 codec decoding, Front Control Pannel with LEDs Indication, 3 nos. USB, iPhone; iPad; Android based Mobile clients, Video Export feature on USB, Search Mode: Time/Date; Alarm; Motion Detection (MD); Exact Search (accurate to a second); Smart Search, Dual HDMI Output, Alarm Input (16 nos.), Alarm Output (6 nos.), eSATA Device, 320Mbps each Incoiming & Outgoing throughput, Operating Temperature –10°C to 55°CCertification : CE, FCC & UL including fixing accessories and cable termination with required connectors/Jack, complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

1

100661

100661.05

... More
Supply , Installation , Testing and commissioning  of 16 Channel NVR (Network Video Recorder), for recording upto 16CH @ 1080P with 08 nos. SATA HDDs minimum 10TB storage or more (recording requirement all cameras recording at 2MP, 25fps for 60 days), H.265 / H.264 / MJPEG/ MPEG4 codec decoding, Front Control Pannel with LEDs Indication, 3 nos. USB, iPhone; iPad; Android based Mobile clients, Video Export feature on USB, Search Mode: Time/Date; Alarm; Motion Detection (MD); Exact Search (accurate to a second); Smart Search, Dual HDMI Output, Alarm Input (16 nos.), Alarm Output (6 nos.), eSATA Device, 320Mbps each Incoiming & Outgoing throughput, Operating Temperature –10°C to 55°CCertification : CE, FCC & UL including fixing accessories and cable termination with required connectors/Jack, complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

1

57930

57930.05

... More
Supply, Installation, Testing & Commissioning of Special Surveillance 8TB 3.5" SATA HDD internal etc. complete in all respect.

6

25122

150736.5

... More
Supply, installation, testing & commissioning with proper connection & termination of following size equipment rack made out of CRCA sheet to house all the control equipment complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

-

-

-

... More
15U Wall Mounted rack

1

28678

28678.6

... More
6U Wall mounted (Outdoor type)

1

12388

12388.95

... More
9U Wall mounted (Outdoor type)

1

20648

20648.25

... More
Supply, installation, testing and commissioning of Layer-3 PoE Managed Distribution Switch 8 Gigabit Ports, Rack Mountable, 2 Port Combo Port POE+ Switch including Fibre module for LAN base feature set with support to integration with CCTV, with all related hardware complete as required and as per specifications

1

126183

126183.75

... More
Supply, installation, testing and commissioning of Layer-2 PoE Managed Distribution Switch 16 Gigabit Ports, Rack Mountable, 2 Port Combo Port POE+ Switch including Fibre module for LAN base feature set with support to integration with CCTV, with all related hardware complete as required and as per specifications

1

166333

166333.6

... More
Supply, installation, testing and commissioning of Layer-2 PoE Managed Distribution Switch 12 Gigabit Ports, Rack Mountable, 2 Port Combo Port POE+ Switch including Fibre module for LAN base feature set with support to integration with CCTV, with all related hardware complete as required and as per specifications

1

126183

126183.75

... More
Supply, installation, testing and commissioning of Layer-2 PoE Managed Distribution Switch 8 Gigabit Ports, Rack Mountable, 2 Port Combo Port POE+ Switch including Fibre module for LAN base feature set with support to integration with CCTV, with all related hardware complete as required and as per specifications

1

86034

86034.85

... More
Supply, installation, testing and commissioning of full HD 43" LED display size colour TFT Monitor including decodes and all accessories complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

1

45885

45885

... More
Supply installation, testing and commissioning of workstation suitable for CCTV Management software- Intel i7 with minimum 3 GHz processor, 2 GB Graphic card with DP to HDMI converter, 16 GB RAM, 2 TB Hard disk, Windows10 downgradable to Windows 7, Latest Anti virus, DVD Writer, Wireless Keyboard and Wireless Mouse as per the requirement of the successful operation of the surveillance system complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

1

101233

101233.9

... More
Supply, installation Testing and commissioning of compatible media converter for the interconnection of switches on optical Fiber cable backbone , complete with patch cord, LIU units and junction boxes as required for integration as per specification complete as required including all support as required.

1

137655

137655

... More
Supply, Installation, Testing and Commissioning of armoured OM3 Single mode fiber optic cable for connectivity where ever required in prelaid conduits / raceways / HDPE / DWC pipes, whichever maybe available etc. as required

100

172

17290

... More
Supply & laying of unarmoured Cat 6 UTP Cables for CCTV's signal/power including cable gland and other required accessories shall be laid in existing conduit/cable tray etc. complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

1400

63

89110

... More
Supply, installation, testing and commissioning of 3 to 4 Meter GI Pole mounted on boundary wall suitable for cameras installation complete as required.

15

9750

146262

... More
Supply, Installation, Testing & Commissioning of EPABX system consists of 16 nos. extensions, 8 nos of junction & upto 64 nos. of expandable eport, with one operating console, 1.35 Amp max. current.

1

108977

108977.35

... More
Supply, Installation, Testing & Commissioning of MDF Box with Mounting Frame, 10 Pair Krone Module Frame as per given Specification etc. all complete. 10 Pair Krone Box

1

10611

10611.5

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair

45

16

749.7

... More
Supplying and drawing following 0.5mm Armoured insulated copper conductor,telephone Power cable in the required surface/ recessed steel/ PVC conduit as required. 10 Pair

25

149

3728.75

... More
Supply, Installation, Testing & Commissioning of faceplate of following configuration inclusive of blank Inserts and corresponding GI backbox assembly. GI backbox assembly shall be provided for outlets installed at wall or at furniture, wooden or any partition at workstation area/device for flush mounting. For exposed mounting, PVC backbox assembly shall be provided. It shall be inclusive of all the necessary mounting accessories and hardware complete as required for a complete installation. Single I/O faceplate

5

1147

5738

... More
Supply, Installation, Testing & Commissioning of Category 6A RJ45 Shielded Modular Jack, ISO/IEC 11801:2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C.2 Category 6A, IEC 60603-7 (603-7), interoperable and backwards compatible with Cat.6, Tooless Termination, Min. 500Mhz, Min. 10Gbps, IDC = 200 Re-Terminations, = 750 Plug Mating Cycles, 1.5A Current, Strain Relief boot for Pairs, Bend Limiting Boot for Cable, Without Proprietary Tool Termination.Suitable for 10GBASE-T applications with Min. 500Mhz Bandwidth. CAT 6A RJ45 Shielded Modular Jack

5

1721

8607

... More
Supply, installation, testing and commissioning of ports with 1000Base-TGigabitPoE SmartManagedSwitch Gigabit PoE/PoE+ offers powerful L2+/Layer 3 Lite features 384W PoE budge , Comprehensive IPv6 supporting management, QoS and ACL,4 Dedicated SFPs, Energy Efficient Ethernet (IEEE802.3az) support for more energy saving in the future when more EEE-compliant end devices come to market, Advanced QoS with IPv4/IPv6 ingress traffic filtering (ACLs) and prioritization (QoS- DiffServ).Dynamic VLAN. 8 Port Switch

1

24003

24003.65

... More
Supply, installation, testing and commissioning of Cat 6A, 23 AWG Solid Bare Copper Conductor U/UTP Unshielded, HDPE Insulation with Diameter 1.0 +/- 0.05mm, PE Cross (+) Filler Between Pairs, Inner FR-PVC Jacket IEC 60332-1 Rated, ECCS Corrugated Tape Armor (Thickness = 0.125mm), Outer UV Resistant HDPE Jacket, 500N Pulling Force, Operating Temperature: -20 to +70Deg, Diameter: 10.7 ± 1.5 mm, in accordance to ANSI/TIA 568 C.2 / ISO/IEC 11801, 500 Mhz Bandwidth, Propagation Velocity : 69% (nominal), Rodent Resistant Outdoor Cable, Mtr, RoHS Complied.Suitable for 10GBASE-T with Min. 500Mhz of Bandwidth.

100

207

20710

... More
Supply, Installation, Testing & Commissioning of Armoured Singlemode (OS2) 9/125 Fiber Cable, ITU G.652.D, G.657A1 & IEC 60794-1 Complied, Outdoor ECCS Armored Fiber Cable with PBT Loose Tube Filled With Thixotropic Jelly, Uni-Tube, Glass Yarn, Water Swellable Tape Under Armor, UV-HDPE Jacket, 8.5 mm Overall Nom. Diameter, Crush Resistant & Tensile Resistant 2200N, Operating Temperature : -30 to + 70 Deg C, Max. Attenuation @1310nm & 1550nm : = 0.36dB/km & = 0.23dB/km Respectively, Black Color 6 Core- Fiber Cable

100

172

17290

... More
Supply, installation, testing & commissioning with proper connection & termination of following size equipment rack made out of CRCA sheet to house all the control equipment including Fastner, FAN, PDU, Cable Manager, Hardware Mounting Kit complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

-

-

-

... More
9U Wall mounted

1

10898

10898.4

... More
15U Wall mounted

2

28678

57357.2

... More
Supply, Installation, Testing & Commissioning of SFTP Cat-6A, Jack Panel for data as per given Specification etc. all complete.  8 Port CAT6A

1

6882

6882.75

... More
Supply, Installation, Testing & Commissioning of 1 U PVC Cable Manager as per given Specification etc. all complete.

3

1721

5164.2

... More
Supply, Installation, Testing & Commissioning of SC MM  Corning multi-mode OM3 Pigtail (1.0 Mtr) 900um Tight Buffer Connector Ferrule: Ceramic per given Specification etc. all complete.

6

975

5853.9

... More
SITC of Cat6A Patch Cord S/FTP 26AWG Bare Copper Stranded Flexible Conductor, LSZH Jacket, ANSI/TIA 568C.2 Category 6A, Support 10GBASE-T with Min. 500Mhz Bandwidth, Operating Temperature -20 ℃ to + 60 ℃, Diameter = 6.0mm Nominal

-

-

-

... More
Patch Cord Cat 6A- 1 meter

3

711

2134.65

... More
Supply, Installation, Testing & Commissioning of 6 socket PDU as per given Specification etc. all complete.

3

2294

6882.75

... More
SITC of Fiber Patch Cord, LC Duplex - LC Duplex, 9/125μm OS2 Singlemode Duplex Zip Cord (= 2.0mm), IL = 0.35dB, RL= 50dB, LSZH Jacket IEC 60332-1, Operating Temperature -40°C to +85°C, Meets ANSI/TIA 568.3-D, Length 3Meter.Cable : LC/LC or LC/SC or SC/SC, 9/125μm OS2 Singlemode Duplex Zip Cord (= 2.0mm) Fiber Patch Cord Single Mode- 3Meter

3

2524

7572.45

... More
SITC of 8Port 1U x 19” LIU Loaded with Multimode LC Adapters & LSZH Pigtails along with Splice Trays, Min. 4 No of Circular Cable Entry with Rubber Groummet/Glands to close any open entry, Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices, Tube for open fibers, Ties, Panel shall be Powder Coated with Min. 1.2mm Metal Sheath, 30 Years Channel Warranty. Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 ,IEC-60332-1, IEC-60754-1, Insertion loss = 0.2 dB, Return Loss = 25, Attenuation: 850/1300 : 3.5/1.50 dB/KM,  Repeatability: = 0.2DB 1000 Times Mating Cycles, RoHS Complied, Meets ANSI/TIA 568.3-D.The optical fiber Pigtails shall be factory loaded inside each individual Port of the panel. Pigtails shall be LSZH with Multi mode 50/125μm fiber LIU Multimode Fibre Panel

3

14339

43017.9

... More
Supply, Installation, Testing & Commissioning of Multimode Unidirectional 1 port SFP 1000Base-SX Duplex LC SFP fiber module single mode

3

13765

41296.5

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal)

50

90

4539.5

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

35

199

6996.85

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)

150

414

62223

... More
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc. in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meter.

360

454

163728

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
Inside size 90x80 cm and 45 cm deep including C.I. Cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

11

9004

99050.6

... More
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 910x555 mm, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

-

-

-

... More
Extra for depth for manholes :

-

-

-

... More
Size 90X80 cm

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

6.05

6195

37482.41

... More
Size 120x90 cm

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

-

-

-

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Rubber Mats as per IS 15652:2006, 2 mm thick, suitable up to 1.1 KV , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top)

5

2065

10326.5

... More
Supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 Sq Meter )

1

97

97.85

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

75

150.1

... More
Supply installation, testing and commissioning of 8 zone IP based, digital voice alarm controller expandable upto 128 zones. The voice alarm controller should be able to connect directly over ethernet without any additional hardware or convertor. It should have functions like the audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover. The voice alarm controller should also have the following functions: . 255 priorities . Time schedule broadcasts . Its own PTT microphone . Capable of amplifier redundancy . 8 trigger inputs/outputs

1

553855

553855.7

... More
Supply, installation, testing and commissioning of IP based networkable touch screen paging station for selection of zones, supervision of system status, setting of scheduled broadcasts with the following functions: . Built-in monitoring loudspeaker . Detachable goose-neck microphone . LCD touch screen display . Audio input

1

152204

152204.25

... More
Supply, installation, testing and commissioning of 4X125W class-D amplifier with 4 independent channels and can provide automatic re-settable over current, overload, overheating, overvoltage, under-voltage and DC protection

1

377424

377424.55

... More
Supply, installation, testing and commissioning of 15W horn speaker (IP66) with max SPL1M/1W 110dB. Frequency response of 500Hz-5KHz with a dispersion angle of 140 deg. The speaker should have tapings at 15W/7.5W

8

9794

78356

... More
Supply, installation, testing and commissioning of 6W ceiling speaker with max SPL1M/1W 96dB. Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tapings at 6W/3W/1.5W (with require mounting arrangement)

15

3441

51627.75

... More
Supply, installation, testing and commissioning of 10W wall mount with max SPL1M/1W 92dB (IP66). Frequency response of 150Hz-17KHz with a dispersion angle of 170 deg. The speaker should have tapings at 10W/5W (with require mounting arrangement)

15

10898

163476

... More
Supply and fixing of PVC insulated copper flexible speaker wire twin FRLS 1100 Volts as per IS:694-1990 of approved make (32/0.2 mm) Twin core 1.00 sq.mm.

1710

40

69853.5

... More
Supply and fixing and concealing of 20 mm dia. 2mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge.

-

-

-

... More
Size 25 mm

1368

68

93571.2

... More
Size 32 mm

342

82

28266.3

... More
Size 40 mm

25

108

2707.5

... More
Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect.

5

14012

70062.5

... More
Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. CAT-AAA

10

3866

38665

... More
Supply and fixing of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect. CAT-AAA

2

7989

15979

... More
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect. CAT- AAA

5

5519

27597.5

... More
Supplying, installation, testing and commissioning of plinth mounted, outdoor type, factory built ready for connection type 200kVA, 11/0.415 kV, 50Hz, compact / unitized substation having type tested equipment comprising distribution transformer and SF6 insulated compact switchgear enclosed in robotically sealed laser sealed/welded stainless steel tank,low voltage switchboard,interconnection between HT switchgear and transformer using cables and transformer to LT switchgear using tinned copper busbars,factory built ready for connection type,internal earthing completed, approved danger and arc flash signages and with all components as mentioned in BOQ, specifications and schedule, complete as required.

1

1252660

1252660.5

... More
HT Compartment : Fully compartmentalized, non extendable, dust/vermin/corrosion proof, powder coated,fully type tested, battery and battery charger, relay and other control accessories), internal arc tested for rated fault current rating for 1s (on front and lateral side), outdoor type,metal enclosed mounted upon suitable size ISMC-100 channel, properly grouted and suitable for 11kV, 630A, 18.5kA for 3sec, 50Hz AC, with SF6 insulated compact switchgear enclosed in stainless steel tank (thickness as per type test design) having IP67 degree of protection,outer structure made up of 2mm thick CRCA sheet & internal partitions of 1.5mm thick CRCA or as per type test design of OEM, approved danger and arc flash signages and with all components as mentioned in BOQ, specifications and schedule, complete as required.

-

-

-

... More
11kV, 50Hz, 630A, 3P, 18.5kA for 3 sec rated VCB breaker with 24 volts DC closing and tripping coils with 24V DC power supply unit, with a provision of secondary trip coil and 230 Volts AC spring charging motor, inbuilt antipumping relay, inbuilt earth switch or earth truck as the case may be, potential free NO & NC contacts required in addition to 4 spare NO and 4 spare NC contacts,LED indication (on, off , trip),emergency button, push buttons(on, off ), auto/manual selector switch, termination facility for 11/11kV (UE) 3C x 240 sqmm aluminium armoured cable, VPIS (voltage presence indication system), inbuilt earth switch of suitable rating connected on the cable side and mechanically interlocked with VCB, spring charge indication, solenoids, interlocks, 8 window annunciation as described in specifications or schedules complete as required.

-

-

-

... More
Metering Air insulated metering panel connected along with above unit, 20KA , 630A having 11000V/\/3 / 110V/\/3, CL-1 & 3P , 50VA, potential transformer with star-star (neutral grounded) connections along with digital voltmeter with inbuilt selector switch, connecting jumpers/busbars , including providing voltmeter, ammeter, Electronic Trivector Meter with MDI including required CTs, space Heater with Thermostat, R,Y,B indication lamp and 6/16A convenience socket, CFL lamp with door limit switch.

-

-

-

... More
Busbar : Busbar made up of electrolytic grade high conductivity copper and suitable for 11 KV, TP 50 Hz, 630 A, 18.5 kA for 3 sec of required length and cross sectional area. Note : Concerning vendor needs to furnish the busbar calculations (for both phase and earth bus) at the time of GA approval and busbar size has to be as per the approved GA drawing.

-

-

-

... More
Numeric relay (1 Nos.) Numeric relay module with LCD dislpay having following inbuilt protection functions : Over voltage, frequency , phase sequence, instantaneous overcurrent,instantaneous earth fault,overcurrent, earth fault, restricted earth fault protection of transformer, high winding temperature and high oil temperature, suitable to record and store at least 100 events with date and time with last five fault records stored in nonvolatile memory and with self supervision function, 4 spare digital binary inputs and 4 spare digital output contacts in addition to those required as per the scheme, modbus communication protocol, breaker control (on/off) along with 3No. 11kV, 50/5A, 15VA, CL-5P10 current transformers, complete as required.

-

-

-

... More
PT fuse failure relay - 1 Nos. Buchholz Relay - 1 nos. Auxilliary relays for WTI & OTI - 01 no. each.

-

-

-

... More
Transformer Transformer compartment comprising of outdoor type oil cooled hermetically sealed corrugated design distribution transformer, 200 kVA, 11KV / 415 Volts , 3 phase, 50 Hz, Dyn11 vector group, impedance 4%, double copper wound, distribution transformer with automatic on load tap changer (suitable for compact sub station mounting) with RTCC panel (outdoor duty). The transformer shall be mounted upon suitable MS channel,with class "A" insulation, winding temperature indicator & oil temperature indicator controller actuated by means of resistance temperature detector embedded in LV windings with approximately 5% impedance,on load tap changer +5 to - 15 % in the steps of 1.25 with AVR, restricted earth fault relay with suitable CT, 24V battery operated hooter (interlocked with door limit switch), lamp (interlocked with door limit switch) and other accessories complete as required. Including supplying and laying copper conductor multicore control cable from transformer to HT breaker for safety tripping complet as required.

-

-

-

... More
The Transformer must confirm to the IS standards specified in the technical specifications.

-

-

-

... More
The total Transformer losses at Rated load, Voltage & frequency to be as per IS 1180 (Energy Efficiency Level 1)

-

-

-

... More
Remote tap changer circuit (RTCC) panel with all associated accessories as per schedules and specifications.

-

-

-

... More
LT Panel : Busbar (1 Set - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 500 A, 16 kA for 1 sec of required length and cross sectional area.

-

-

-

... More
Outgoing: 1x400 A, FP MCCB, 16 KA microprocessor based with LSIG protection, LED indication lamps (on / off / trip, phase indication lamps) with back up MCB, 230V space heater with thermostat, 3-pin convenience outlet, a lamp along with its operating switch and door limit switch operation, three phase multifunction meter with selector switch digital type, accuracy class-0.5 (96mm X 96mm) with ethernet IP communication port & 1 set of suitable CTs, suitable for measuring THD, KVARH, KW, KWH, KVAR, PF, V, A, Hz complete required and confirming to detailed specifications. The MCCB shall have suitable arrangement for termination of armoured aluminium cable as per single line diagram.

-

-

-

... More
Inbuilt Capacitor Bank (60kvar) : 1 x 9 numeric type stepped relay (APFCR) with 9 steps (each to be of 10/15/25/50/100 KVAR as required) for automatic power factor correction having facility to change the sequence of switching 'ON' the capacitor banks as required. The program of APFCR shall be re settable to enable sequance of ON/OFF of individual bank, so that the end unit of capacitor bank is not kept idle for long. 1x160 A, FP MCCB, 16 KA microprocessor based with LSIG protection 3 nos. 160/5A, CL-1, 10VA, ring type CT for 240V actuated numeric type APFC relay

-

-

-

... More
Enclosure of capacitor panel shall be liberally designed to take care of internal heat emission by capacitor unit without forced cooling and to limit the temperature rise with in permissible limit.

-

-

-

... More
1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 3X160/5A, 10VA Class 1.0 CTs)

-

-

-

... More
Outgoings : 2 x (32 Amp, 25kA, TP, MCCB (TM Based) + capacity ducty contact + 7% detuned reactor + 15kVAr MPPH type heavy duy capacitor) (rated at 480V with min 20.07 kVAr @ 480V) 2 x (25 Amp, 25kA, TP, MCCB (TM Based) + capacity ducty contact + 7% detuned reactor + 10kVAr MPPH type heavy duy capacitor) (rated at 480V with min 13.30 kVAr @ 480V) 2 x (16 Amp, 25kA, TP, MCCB (TM Based) + capacity ducty contact + 7% detuned reactor + 5kVAr MPPH type heavy duy capacitor) (rated at 480V with min 6.65 kVAr @ 480V) Indication lamps LED type Indication lamps for breaker, suitable for 230V,50Hz AC supply (on, off, trip) - 9 sets 15 kVAr A/M switch, On/Off push buttons and Red/Green indication lamps - 2 Nos. 10 kVAr A/M switch, On/Off push buttons and Red/Green indication lamps - 2 Nos. 5 kVAr A/M switch, On/Off push buttons and Red/Green indication lamps - 2 Nos. Note : Capacitor shall be 480V rated and corrected compensation at 480V shall be ensured by the capacitor manufacturers

-

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 sq. mm and upto 400 sq. mm

20

401

8029.8

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm

80

93

7463.2

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 240 sq. mm

4

9729

38919.6

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 240 sq. mm

2

14298

28597.46

... More
Supplying 11KV (UnEarthed) grade, XLPE insulated, heavy duty FRLS type, armoured cables suitable for 11kV, 50Hz, AC system with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel flat armouring and with all components as mentioned in BOQ, specifications and SLD, complete as required. 3 core x 240 sq. mm

100

2237

223725

... More
FIRE FIGHTING WORK

-

-

-

... More
CHAPTER 1: PUMPS

-

-

-

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)

-

-

-

... More
Horizontal type, multistage, centrifugal, split pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520

-

-

-

... More
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
450 lpm at 35 m Head

1

71180

71180.23

... More
CHAPTER 2: PIPES AND ACCESSORIES

-

-

-

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

3

5069

15207.42

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)

6

3672

22037.04

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)

3

1372

4117.08

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
25 mm dia

2

614

1228.68

... More
80 mm dia

5

1556

7782.5

... More
100 mm dia

150

2109

316459.5

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
80 mm dia

3

4113

12341.34

... More
100 mm dia

2

5505

11010.26

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia

1

9124

9124.29

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia

1

5502

5502.65

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe

1

5567

5567.06

... More
CHAPTER 3: MISCELLANEOUS ACCESSORIES

-

-

-

... More
Supplying, installation, testing and commissioning of Mild Steel Air cushion tank on top of each riser/downcomer fabricated from 6mm thick heavy duty type C Mild steel plate or pipe for the shell, 8mm thick heavy duty type C Mild steel plate for the dish end, 250 mm in diameter and 1.2 m in height with supporting structure fabricated from 40x40x5mm angle frame with 25 mm diameter Air release valve at the top & 25 mm diameter stop cock at the bottom with flanged inlet connections with all accessories as required. The Vessel shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved shade or as required in consultation and approval of the engineer in charge. The Air cushion tank shall be rated to withstand the working pressure and a minimum of 10 bar pressure requirement.

1

18927

18927.8

... More
Providing and fixing weather proof lockable cabinet of size not less than 0.9 x 0.6 x 0.45 mtr made out of MS sheet of 16 gauge thickness having central opening and 4 mm thick glazed glass doors (Two No.) suitably marked on the outside with the letters "FIRE HOSE" including necessary locking arrangement and shall be painted with one coat of primer and two coats of stove enamel paint of approved shade. (The aesthetics and design of the cabinet shall be as per the architect / Client). (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hamer).

3

17207

51622.05

... More
CHAPTER 4: FIRE EXTINGUISHER

-

-

-

... More
Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner).

-

-

-

... More
Supply, installation, testing and commissioning of ISI marked handheld dry chemical powder type ABC-90% (Mono ammonium phosphate and ammonium sulphate) fire extinguisher with minimum sheet thickness of 1.6mm, epoxy powder coating on the inner side and epoxy polyster powder coating on the outside, tested via helium leak detection test conforming to IS: 15683:2018 with gun metal cap and nozzle complete in all respects including initial fill and wall suspension brackets.

9

3269

29429.1

... More
Supply, installation, testing and commissioning of ISI marked handheld 4.5kg CO2 based fire extinguisher (PESO certified), epoxy powder coating on the inner side and epoxy polyster powder coating on the outside, tested via helium leak detection test conforming to IS: 15683:2018 with gun metal cap and nozzle complete in all respects including initial fill and wall suspension brackets.

9

5736

51624.9

... More
GST Extra as applicable

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.