Uttar Pradesh Projects Corporation Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Projects Corporation Limited - UPPCL Tender

Works
Civil And Construction
Eprocure
Opening Date21 Dec 2022
Closing Date28 Dec 2022
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work.

19.2

-

874

... More
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm.

128.52

-

180.5

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Footing foundation excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.

47.25

-

7408.22

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Plinth Beam excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item

13.55

-

7555.68

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Column excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item

-

-

-

... More
Ground floor

10.81

-

9123.18

... More
First floor

7.12

-

9123.18

... More
Second floor

7.12

-

9123.18

... More
Third floor

8.6

-

9123.18

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Lintel excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item

-

-

-

... More
Ground floor

2.09

-

7555.68

... More
First floor

1.78

-

7555.68

... More
Second floor

1.78

-

7555.68

... More
Third floor

1.82

-

7555.68

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Projection excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item

-

-

-

... More
Ground floor

2.42

-

8401.18

... More
First floor

2.42

-

8401.18

... More
Second floor

2.42

-

8401.18

... More
Third floor

2.48

-

8401.18

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Beam excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item

-

-

-

... More
Ground floor

10.86

-

8937.72

... More
First floor

9.82

-

8937.72

... More
Second floor

9.82

-

8937.72

... More
Third floor

10.32

-

8937.72

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Slab excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item

-

-

-

... More
Ground floor

12.97

-

8401.18

... More
First floor

12.84

-

8401.18

... More
Second floor

12.84

-

8401.18

... More
Third floor

13.08

-

8401.18

... More
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks.

-

-

-

... More
Ground floor

143.02

-

7163.31

... More
First floor

50.99

-

7163.31

... More
Second floor

50.99

-

7163.31

... More
Third floor

56.21

-

7163.31

... More
Class-150 (Non Modular) brick work in 1:6 cement and Coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work.

5.96

-

5114.64

... More
Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) (230mm wall)

-

-

-

... More
Ground floor

30.41

-

5580.14

... More
First floor

29.21

-

5580.14

... More
Second floor

29.21

-

5580.14

... More
Third floor

38.98

-

5580.14

... More
Same as in item no. 14but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.

-

-

-

... More
Ground floor

16.42

-

5979.84

... More
First floor

7.34

-

5979.84

... More
Second floor

6.75

-

5979.84

... More
Third floor

9.62

-

5979.84

... More
Structural steel work Hold Fast in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

-

-

-

... More
Ground floor

114

-

72.69

... More
First floor

78

-

72.69

... More
Second floor

78

-

72.69

... More
Third floor

85.2

-

72.69

... More
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.

-

-

-

... More
Ground floor

241.95

-

81

... More
First floor

135.9

-

81

... More
Second floor

135.9

-

81

... More
Third floor

135.9

-

81

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces

4.2

-

3734.51

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (35mm thick)

-

-

-

... More
Ground floor

27.72

-

1349

... More
First floor

9.45

-

1349

... More
Second floor

9.45

-

1349

... More
Third floor

9.45

-

1349

... More
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer- in-Charge.

-

-

-

... More
Ground floor

7.2

-

318.88

... More
First floor

7.2

-

318.88

... More
Second floor

7.2

-

318.88

... More
Third floor

7.2

-

318.88

... More
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.

-

-

-

... More
Ground floor

6.3

-

1917.65

... More
First floor

6.3

-

1917.65

... More
Second floor

6.3

-

1917.65

... More
Third floor

6.3

-

1917.65

... More
Structural steel work Z-Section in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

-

-

-

... More
Ground floor

770.63

-

81

... More
First floor

622.13

-

81

... More
Second floor

622.13

-

81

... More
Third floor

624.11

-

81

... More
Structural steel work Grill in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

-

-

-

... More
Ground floor

616.5

-

81

... More
First floor

497.7

-

81

... More
Second floor

497.7

-

81

... More
Third floor

499.68

-

81

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with (4.0mm thick float glass)

-

-

-

... More
Ground floor

30.83

-

745.45

... More
First floor

24.89

-

745.45

... More
Second floor

24.89

-

745.45

... More
Third floor

26.87

-

745.45

... More
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.

5.67

-

7340.18

... More
Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete.

2.63

-

1159.68

... More
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters Kiln seasoned and chemically treated hollock wood

-

-

-

... More
Ground floor

5.36

-

2452.14

... More
First floor

5.36

-

2452.14

... More
Second floor

5.36

-

2452.14

... More
Third floor

5.36

-

2452.14

... More
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides

-

-

-

... More
Ground Floor

30.83

-

571.78

... More
First floor

24.89

-

571.78

... More
Second floor

24.89

-

571.78

... More
Third floor

26.87

-

571.78

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16mm

-

-

-

... More
Ground floor

16

-

183.48

... More
First floor

10

-

183.48

... More
Second floor

10

-

183.48

... More
Third floor

10

-

183.48

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x16mm

-

-

-

... More
Ground floor

22

-

81.55

... More
First floor

20

-

81.55

... More
Second floor

20

-

81.55

... More
Third floor

22

-

81.55

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm

-

-

-

... More
Ground floor

14

-

46.9

... More
First floor

10

-

46.9

... More
Second floor

10

-

46.9

... More
Third floor

10

-

46.9

... More
12mm thick plaster in inner walls with proportion of 1:6 cement & approved coarse sand

-

-

-

... More
Ground floor

366.64

-

128.61

... More
First floor

220.53

-

128.61

... More
Second floor

220.53

-

128.61

... More
Third floor

251.93

-

128.61

... More
12mm thick plaster in Outer walls with proportion of 1:6 cement & approved coarse sand

-

-

-

... More
Ground floor

354.23

-

128.61

... More
First floor

286.81

-

128.61

... More
Second floor

253.57

-

128.61

... More
Third floor

405.02

-

128.61

... More
Supply & filling of cinder in sunken portion of building including breaking into required sizes including supply of all material, labour, T&P required for proper completion of work.

-

-

-

... More
First floor

1.58

-

1681.5

... More
Second floor

1.58

-

1681.5

... More
Third floor

1.58

-

1681.5

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:

-

-

-

... More
Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.

-

-

-

... More
IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.

-

-

-

... More
IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.

-

-

-

... More
IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).

-

-

-

... More
First floor

19.86

-

613.81

... More
Second floor

19.86

-

613.81

... More
Third floor

19.86

-

613.81

... More
Terrace floor

19.86

-

613.81

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

-

-

-

... More
Ground floor

87.97

-

902.5

... More
First floor

57.08

-

902.5

... More
Second floor

57.08

-

902.5

... More
Third floor

57.08

-

902.5

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

-

-

-

... More
Ground floor

13.12

-

902.5

... More
First floor

13.12

-

902.5

... More
Second floor

13.12

-

902.5

... More
Third floor

13.12

-

902.5

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (40mm)

-

-

-

... More
Ground floor

52.98

-

389.5

... More
First floor

11.92

-

389.5

... More
Second floor

11.92

-

389.5

... More
Third floor

11.92

-

389.5

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.

-

-

-

... More
Ground floor

23.08

-

452.48

... More
First floor

19.06

-

452.48

... More
Second floor

19.06

-

452.48

... More
Third floor

19.06

-

452.48

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (Kajaria. Somany or Equivalent)

-

-

-

... More
Ground floor

47.42

-

979.45

... More
First floor

62.35

-

979.45

... More
Second floor

62.35

-

979.45

... More
Third floor

62.35

-

979.45

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.. (Size of Tile 600x600 mm)(Kajaria. Somany or Equivalent)

-

-

-

... More
Ground floor

7.2

-

979.45

... More
First floor

4.92

-

979.45

... More
Second floor

4.92

-

979.45

... More
Third floor

4.92

-

979.45

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red

-

-

-

... More
Ground floor

5.58

-

3508.31

... More
First floor

5.58

-

3508.31

... More
Second floor

5.58

-

3508.31

... More
Third floor

5.58

-

3508.31

... More
Providing and laying Brick Coba " 12 mm thick laid with M.150 class brick bat coba 7.50 cm. Thick with gap of 15 mm to each other over 20 mm. Thick base of Cement morter 1 : 4 Cement and Coarse Sand mixed with water proo fing compound gaps of coba & top of coba mortar mixed with water proofing compoond. in 1 : 4 Cement & coarse & morter finished smooth & top mashed false

-

-

-

... More
square 30 cm X 30 cm. & side wall parapet shall be mono tythic plaster wall up to 30 cm.higher & junction & corner shall be rounded by brick ballast Cement and Coarsespreading Cement slurry mixed with aerelic Cement concrete waterproofing compound filed Sand masonary coba with top finished mixed with acetic water proofing compound @ 2% by weight & including S / O all material, labour, T & P etc. required for proper completion of work.

118.49

-

1045

... More
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete.

-

-

-

... More
Ground floor

762.16

-

98.19

... More
First floor

574.53

-

98.19

... More
Second floor

541.28

-

98.19

... More
Third floor

739.1

-

98.19

... More
One priming coat & one coat oil distemper on new work including supply of material, labour T&P etc. required for proper completion of the work. (Two Coat)

-

-

-

... More
Ground floor

407.93

-

69.35

... More
First floor

450.26

-

69.35

... More
Second floor

287.72

-

69.35

... More
Third floor

334.09

-

69.35

... More
Finishing walls with Primium Acrylic Smooth exterior paint of required shade :

-

-

-

... More
New work (Two or more coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)(Apex, Ultima, Weather Coat, All guard) Asian, Berger,

-

-

-

... More
Ground floor

354.23

-

87.4

... More
First floor

286.81

-

87.4

... More
Second floor

253.57

-

87.4

... More
Third floor

405.02

-

87.4

... More
Painting or vernishing on iron work in small areas of new work with one coat of rady mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic vernish, including supply of all materials, labour and T&P etc. required for proper completion of work.

-

-

-

... More
Ground floor

84.07

-

61.75

... More
First floor

48.11

-

61.75

... More
Second floor

48.11

-

61.75

... More
Third floor

48.11

-

61.75

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

-

-

-

... More
Ground floor

342.46

-

478.11

... More
First floor

342.46

-

478.11

... More
Second floor

342.46

-

478.11

... More
Third floor

342.46

-

478.11

... More
Making Apron

38.01

-

637.46

... More
PLUMBING WORK

-

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.

8

-

4583.31

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap

8

-

2165.43

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink without drain board 510x1040 mm bowl depth 250 mm

2

-

4763.35

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

10

-

640.68

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Flexible pipe

-

-

-

... More
i) 32 mm dia

8

-

82.73

... More
ii) 40 mm dia

8

-

82.73

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

8

-

1340.59

... More
Providing and fixing soil, waste and vent pipes : Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989

-

-

-

... More
75 mm O.D.

50

-

826.15

... More
110 mm O.D.

50

-

854.14

... More
Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

-

-

-

16

-

246.43

... More
110 mm

16

-

245.32

... More
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :

-

-

-

... More
75 mm O.D.

8

-

109.96

... More
110 mm O.D.

8

-

129.58

... More
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :

-

-

-

12

-

241.36

... More
110 mm

12

-

244.53

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain)

-

-

-

... More
75 mm Shoe

16

-

64.29

... More
110 mm Shoe

16

-

91.92

... More
Providing and fixing plain bend of required degree. Sand cast iron S&S as per IS - 3989

-

-

-

... More
75 mm size

8

-

236.41

... More
110 mm size

8

-

348.62

... More
Providing and fixing heel rest sanitary bend Sand cast iron S&S as per IS - 3989

-

-

-

... More
75 mm size

5

-

321.27

... More
110 mm size

5

-

348.62

... More
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 3989

-

-

-

... More
75 mm size

8

-

359.44

... More
100 mm size

8

-

473.76

... More
Providing and fixing terminal guard : Sand cast iron S&S as per IS - 3989

-

-

-

10

-

246.99

... More
100 mm

10

-

348.62

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :

10

-

1112.62

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall

-

-

-

... More
15 mm nominal outer dia pipes

-

-

-

... More
20 mm nominal outer dia pipes

60

-

295.98

... More
25 mm nominal outer dia pipes

60

-

466.64

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Internal work - Exposed on wall

-

-

-

... More
20 mm nominal outer dia Pipes

40

-

257.73

... More
25 mm nominal outer dia Pipes

60

-

323.89

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.

-

-

-

... More
15 mm nominal outer dia pipes

70

-

349.73

... More
20 mm nominal outer dia pipes

70

-

407.29

... More
Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. External work

-

-

-

... More
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)

-

-

-

... More
25mm dia, nominal bore

10

-

422.03

... More
Providing and fixing uplasticised PVC connection pipe with brass unions :

-

-

-

... More
45 cm length

-

-

-

... More
15 mm nominal bore

20

-

67.54

... More
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls)

-

-

-

... More
20 mm nominal outer dia pipes

65

-

15.58

... More
25 mm nominal outer dia pipes

65

-

20.3

... More
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work

-

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :

-

-

-

... More
20 mm nominal bore

8

-

315.09

... More
Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)

-

-

-

... More
20mm nominal bore

9

-

229.15

... More
25mm nominal bore

9

-

187.1

... More
Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931

-

-

-

... More
15mm nominal bore

11

-

344.22

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.

-

-

-

... More
15mm nominal bore

11

-

561.6

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.

-

-

-

... More
15 mm nominal bore

18

-

396.67

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

3500

-

7.58

... More
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m :

-

-

-

... More
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.

80

-

330.87

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :

-

-

-

... More
150 mm O.D.

60

-

390.92

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :

-

-

-

... More
160/150 mm diameter pipe

60

-

868.21

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

2008.89

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design :

-

-

-

... More
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

9265.24

... More
Extra over Item No. 24.27 for every additional depth of 0.10 metre or part there of main hole. (a) Size 900 x 800 mm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

6443.24

... More
SEPTIC TANK & SOAK PIT

-

-

-

... More
Earth work in excavation (PWD 251)

49.1

-

114

... More
P.C.C. in 1 : 4: 8 with cement, c. sand & 40 mm gauge stone ballast (PWD 281)

1.39

-

5179.59

... More
Brick work in foundation in 1 : 4 cement & coarse sand(PWD305B)

7.37

-

5329.09

... More
R. C. C. in 1 : 1.5 : 3 in Slab (Analysis )

1.12

-

8401.18

... More
Reinforcement Work (PWD-504)

0.88

-

7163.31

... More
Brick work in foundation in 1 : 4 sand(PWD307)

0.68

-

5329.09

... More
40mm thick c.c. flooring (PWD605)

10.53

-

390.93

... More
18 mm thick plaster in 1: 3 cement & Course sand (DSR 11.6.1)

32.76

-

452.48

... More
Supply & Febrication of M. S. Steps

24.7

-

72.69

... More
500 mm diameter C.I. cover (medium duty) the cover to be not less than 58 kg (dsr19.18.2)

2

-

2551.94

... More
C.I. Cowel (DSR 17.56.1.2)

2

-

348.62

... More
C.I. Plain bend (DSR 17.39.1.2)

2

-

343.48

... More
C.I. Single equal plaing junction (DSR 17.44.1.2)

2

-

552.47

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.32.1)

1

-

22220.81

... More
Point Wiring :

-

-

-

... More
Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backalite sheet etc.complete in all respect as directed including matching colour wash.

117

-

579.5

... More
Wiring point for two ways light point with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box and two number two ways piano type switches & ceiling rose/angle/batten holder on 3mm thick , phenolic laminated backelite sheet etc., complete in all respect,as directed, including matching colour wash.

4

-

751.45

... More
Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backelite sheet,etc.complete in all respect,as directed, including matching colour wash.

54

-

637.45

... More
Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & socket etc.complete in all respect, as directed, including matching colour wash.

68

-

310.65

... More
Wiring point for Exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box and 15 amp piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backelite sheet etc.complete in all respect, as directed, including matching colour wash.

6

-

848.35

... More
Add for light /fan point with moduler type switch in place of piano type switch.

116

-

41.8

... More
Add for 2 way light point with moduler type switch in place of piano type switch.

4

-

156.75

... More
Add for plug point with moduler type switch in place of piano type switch.

68

-

78.85

... More
Add for HPMV/Exhaust Fan point with moduler type switch in place of piano type switch.

6

-

44.65

... More
Submains (Cooper Wires) :

-

-

-

... More
Supply & wiring of submains with 2 nos.1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 1.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect.

770

-

99.75

... More
Supply & wiring of submains with 2 nos.2.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slabalong with the reinforcement before concreting, with 1 no. 1.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect.

350

-

114.95

... More
Supply & wiring of submains with 2 nos.4 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 2.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect.

90

-

141.55

... More
Supply & wiring of submains with 2 nos.6 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 4 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect.

20

-

193.8

... More
Supply & wiring of submains with 4 nos. 6 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2 no. 6 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect.

120

-

342

... More
Supply & wiring of submains with 4 nos.10 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 40 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2 no. 6 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect.

120

-

479.75

... More
Lighting Fixtures (Lights/Fans) :

-

-

-

... More
Supply & fixing of Batton/Angle holder including making connection etc. as required.

28

-

57

... More
Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA

74

-

1130.5

... More
Supply and fixing of water tight oblong 10 Watt LED bulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA

16

-

1330

... More
Supply and fixing of 3 watt to 6 watt LED (spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a Decorative Mirror Light)

8

-

1757.5

... More
Supply of ceilling fans with fan motor of A.C. Permanent insulation, capacitor rating conforming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts,50 Hz, 1-Ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system.

-

-

-

... More
BEE 5 Star rated-1200 mm sweep

32

-

1710

... More
Armoured Cables (Cable/Gland/Lug) :

-

-

-

... More
Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size

-

-

-

... More
size 35 sq mm x 3-1/2core

50

-

400.9

... More
Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer-incharge. for cable

-

-

-

... More
size 35 sq mm x 3-1/2core

2

-

169.1

... More
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable

-

-

-

... More
size 35 sq mm

2

-

29.45

... More
Earthing Work :

-

-

-

... More
Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified.

2

-

11115

... More
Supply and laying of 25mm x 3 mm G.I. strip from earth electrode directly in the ground as required complete in all respects.

30

-

85.5

... More
Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB’s (Four Pole 36 KA with thermal magnatic release) Switches complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB’s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.

-

-

-

... More
The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A & B only.

-

-

-

... More
The minimum clearances between bus bars shall be as follows :

-

-

-

... More
Phase to phase - minimum 20mm

-

-

-

... More
Phase to neutral-minimum 15mm

-

-

-

... More
CUBICAL PANEL BOARD ( MCCB TYPE )

-

-

-

-

-

-

... More
Incoming :

-

-

-

... More
one (1) No.200Amp. MCCB-1No.

1

-

131166.5

... More
Bus Bar :

-

-

-

... More
One (1) No.200 A, TPN aluminimum bus bar of suitable length.

-

-

-

... More
Outgoing :

-

-

-

... More
100 Amp. 4P MCCB- 2 No. ( VTPN D.B)

-

-

-

... More
63 Amp. 4P MCB- 4 No.

-

-

-

... More
40 Amp.4P MCB- 4 No.

-

-

-

... More
63 Amp.4P MCCB- 2 No. (spare)

-

-

-

... More
OR outgoing as per site requirment(AS/SLD)

-

-

-

... More
(Complete as per requirment directed by Project Manager.)

-

-

-

... More
DBs & MCBs :

-

-

-

... More
Supply and fixing of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. CAT A

220

-

247

... More
Supply and fixing of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve. CAT A

2

-

703

... More
Supply and fixing of 6 Amp. to 32 Amp. TP MCB (10 KA) C Curve. CAT A

2

-

1130.5

... More
Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A

3

-

1691

... More
Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A

3

-

1700.5

... More
Supply and fixing of 40 Amp. FP MCB (10 KA) C Curve. CAT A

6

-

2161.25

... More
Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A

6

-

2175.5

... More
Supply and fixing of 100 amp 4 pole MCCB (25 KA ) thermal magnetic relese. CAT A

2

-

7733

... More
Supply and fixing of surface/Flush mounting 4ways SPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. CAT A

2

-

1510.5

... More
Supply and fixing of surface/Flush mounting 4 ways TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. CAT A

6

-

3429.5

... More
Supply and fixing of surface/ Flush mounting 4ways VTPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. CAT A

2

-

8132

... More
Supply and fixing of surface/Flush mounting 6 ways TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. CAT A

5

-

4151.5

... More
Miscellaneous Items :

-

-

-

... More
Supply and Fixing of Danger Board fabricated from 10 gauge M.S. Sheet as per I.E. Rules

1

-

80.75

... More
Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.

32

-

133

... More
Erection and testing of exhaust fan on the existing hole with suitable size rag bolt nut & washer etc. complete in all respects.

8

-

185.25

... More
Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finshing propely complete in all respect.

8

-

769.5

... More
Supply and Fixing of shock treatment chart prescribed as per I.E. Rules.duly framed with glass and supported from back with hard board or shoft board with supply of all material ,labour,T&P for proper completion of work.

1

-

289.75

... More
Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules.

1

-

2422.5

... More
Supply and fixing of power plug with 20A/250V flush type Moduler switch and 5 Pin 20A/250V flush type universal Moduler socket in suitable Conceled MS Box including supply of all material, labour,T&P etc.required for proper completion of work.

42

-

593.75

... More
S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.

32

-

142.5

... More
Electronic Items :

-

-

-

... More
Supply fixing of electronic fan regulator (Modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.

32

-

491.15

... More
Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect.

30

-

266

... More
Supply & fixing of 225/230mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect.

8

-

1767

... More
Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect.

2

-

2770.2

... More
Fire Extinguishers :

-

-

-

... More
Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

6

-

7467

... More
Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

12

-

11381

... More
BORING

-

-

-

... More
Supply,Instalation & Boring 6" dia 50 mtr deep with 110 mm dia PVC pipe (45 mtr pvc pipe & 15 mtr slotted PVC pipe with 2 HP submersible pupm including all material labour and T&P etc . Complete in all respects.

1

-

155800

... More
INTERLOCKING

-

-

-

... More
Earth work in excavation

36

-

114

... More
P.C.C. in 1 : 4 : 8 with cement, c. sand & 40 mm gauge stone ballast

4.5

-

5179.59

... More
Granuler Sub Base in interlocking Area

10.4

-

2107.28

... More
Brick work in foundation in 1 : 4 cement & coarse sand

13.9

-

5329.09

... More
P /F 80 mm thick cement concrete interlocking paver block of M-30.

104

-

931

... More
Sand filling

3.1

-

874

... More
VIVECHNA ROOM

-

-

-

... More
Excavation in foundation in ordinary soil (Loam Clay or sand) including lift upto 1.5m (5fts) and lead upto 30mm (100fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directd by the Engineer-in-Charge upto a distance of 30m (100 fts) from the foundation trenches.

65.26

-

114

... More
Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.

11.92

-

5179.59

... More
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work.

7.41

-

874

... More
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground

-

-

-

... More
floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm

-

-

-

... More
(4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm.

49.41

-

180.5

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in foundation excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.

0.78

-

7408.22

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Plinth BEAM excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.

1.53

-

7555.68

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Column excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item

0.59

-

9123.18

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Lintel excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item

2.67

-

7555.68

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Projection excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item

0.27

-

8401.18

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Beam excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item

1.89

-

8937.72

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Slab excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item

8.26

-

8958.5

... More
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks.

16.44

-

7163.31

... More
First Class brick work in 1:6 cement and coarse sand of 2.25 F.M. mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse sand)

34.9

-

5114.64

... More
Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) (230mm wall)

25

-

5580.14

... More
Same as in item no. 15 but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.

6.83

-

5979.84

... More
Structural steel work Hold Fast in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

57.6

-

72.69

... More
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.

172.8

-

81

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

15.12

-

1349

... More
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer- in-Charge.

9.9

-

318.88

... More
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered

-

-

-

... More
in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification.

3.15

-

1917.65

... More
Structural steel Z-Section work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

292.5

-

81

... More
Structural steel Grill work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

234

-

81

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with (4.0mm thick float glass) 4.0 mm thick glass panes

11.7

-

745.45

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16mm

18

-

183.48

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x16mm

18

-

81.55

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm

10

-

46.9

... More
12mm thick plaster in inner walls with proportion of 1:6 cement & approved coarse sand

126.98

-

128.61

... More
12mm thick plaster in Outer walls with proportion of 1:6 cement & approved coarse sand

211.23

-

128.61

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete... (Size of Tile 600x600 mm) (Kajaria. Somany or Equivalent)

28.8

-

979.45

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.. (Size of Tile 600x600 mm)(Kajaria. Somany or Equivalent)

4.32

-

979.45

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (40mm)

16.48

-

390.93

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.

9.21

-

452.48

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete

6.78

-

902.5

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

29.63

-

902.5

... More
Providing and laying Brick Coba " 12 mm thick laid with M.150 class brick bat coba 7.50 cm. Thick with gap of 15 mm to each other over 20 mm. Thick base of Cement morter 1 : 4 Cement and Coarse Sand mixed with water proo fing compound gaps of coba & top of coba mortar mixed with water proofing compoond. in 1 : 4 Cement & coarse & morter finished smooth & top mashed false

-

-

-

... More
square 30 cm X 30 cm. & side wall parapet shall be mono tythic plaster wall up to 30 cm.higher & junction & corner shall be rounded by brick ballast Cement and Coarsespreading Cement slurry mixed with aerelic Cement concrete waterproofing compound filed Sand masonary coba with top finished mixed with acetic water proofing compound @ 2% by weight & including S / O all material, labour, T & P etc. required for proper completion of work.(The waterproofing work to be carried out by specilized agencies and veryfy the all documents mentioned in office order no. 3690/P.C.L/Head Office/ T-6)

59.69

-

1045

... More
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete.

374.79

-

98.19

... More
One priming coat & one coat oil distemper on new work including supply of material, labour T&P etc. required for proper completion of the work. (Two Coat)

163.56

-

69.35

... More
Finishing walls with Primium Acrylic Smooth exterior paint of required shade :

-

-

-

... More
New work (Two or more coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)(Apex, Ultima, Weather Coat, All guard) Asian, Berger,

211.23

-

87.4

... More
Painting or vernishing on iron work in small areas of new work with one coat of rady mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic vernish, including supply of all materials, labour and T&P etc. required for proper completion of work.

48.31

-

61.75

... More
Making Apron

24.16

-

637.46

... More
PLUMBING WORK

-

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:

-

-

-

... More
W.C. pan with ISI marked black solid plastic seat and lid

2

-

4392.41

... More
Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required.

-

-

-

... More
a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

2

-

2689.77

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.

-

-

-

... More
Semi rigid pipe

-

-

-

... More
32 mm dia

2

-

71.04

... More
CP Brass fittings

-

-

-

... More
Providing and fixing unplasticised PVC connection pipe with brass unions

-

-

-

... More
45 cm length

-

-

-

... More
15 mm nominal bore

2

-

66.55

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931

-

-

-

... More
a) 15 mm nominal bore

2

-

339.15

... More
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931

-

-

-

... More
a) 15 mm nominal bore

2

-

390.82

... More
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

-

-

-

6

-

241.75

... More
Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.

-

-

-

... More
110 mm

8

-

249.75

... More
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.

-

-

-

... More
Coupler

-

-

-

... More
110 mm Bend

2

-

93.69

... More
Bend 87.5 degree

-

-

-

... More
110 mm Bend

3

-

103.1

... More
Shoe (Plain)

-

-

-

... More
110 mm Shoe

3

-

90.57

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

2

-

37.41

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.

2

-

211.35

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Concealed work including cutting chases and making good the walls etc.

-

-

-

... More
20mm dia nominal outer dia pipes

18

-

401.29

... More
25mm dia nominal outer dia pipes

12

-

489

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Internal work-Exposed on wall

-

-

-

... More
15mm dia nominal bore

16

-

199.88

... More
20mm dia nominal bore

18

-

253.93

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
20mm dia nominal bore

27

-

172.89

... More
Providing and fixing gun metal gate valve with wheel of approved quality.

-

-

-

... More
20mm dia nominal bore

1

-

360.67

... More
25mm dia nominal bore

1

-

415.81

... More
Providing and fixing brass stop cock of approved quality.

-

-

-

... More
b) 20 mm nominal bore

2

-

256.16

... More
Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].

-

-

-

... More
Capcity in Per Liters

1000

-

7.58

... More
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m.

-

-

-

... More
All kinds of soil

-

-

-

... More
Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm.

8

-

325.99

... More
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.

-

-

-

... More
100mm diameter

8

-

297.89

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design

-

-

-

... More
100mm dia

5

-

709.93

... More
Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design

-

-

-

... More
150 x 100 mm size P type

-

-

-

... More
With Sewer bricks conforming to IS : 4885

2

-

1925.21

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C.

-

-

-

... More
top slab with 1:1.5:3 mix (1 cement : 1.5 Fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:

-

-

-

... More
Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

-

5793.72

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone

-

-

-

... More
aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:

-

-

-

... More
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

1

-

8009.01

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design

-

-

-

... More
With 20x20 mm square bar

2

-

360.36

... More
Providing and fixing in floor and wall face Ringfit UPVC ASTRAL/EQUIVALENT ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.

-

-

-

... More
a) 110mm dia P.V.C. pipe

34

-

579.5

... More
b) 90mm dia P.V.C. pipe

26

-

484.5

... More
Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince)

-

-

-

... More
P-Trap type Floor Trap 110 x 90 mm

4

-

256.5

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.

-

-

-

... More
110mm bend

3

-

209

... More
90 mm bend

3

-

194.75

... More
Coupler

-

-

-

3

-

142.5

3

-

133

... More
Single tee with door

-

-

-

... More
90x90x90 mm

1

-

232.75

... More
110x110x110 mm

1

-

318.25

... More
SEPTIC TANK

-

-

-

... More
Earth work in excavation (PWD 251 )

41.18

-

114

... More
P.C.C. in 1 : 4: 8 with cement, c.

-

-

-

... More
sand & 40 mm gauge stone ballast (PWD 281)

1.87

-

5179.59

... More
Brick work in foundation in 1 : 4

-

-

-

... More
cement & coarse sand(PWD 305)

6.01

-

5329.09

... More
R. C. C. in 1 : 1.5 : 3 in Slab (PWD-284A)

0.85

-

8401.18

... More
Reinforcement Work (PWD-aNALYSIS)

0.67

-

7163.31

... More
Brick work in 1 : 4 cement & coarse

-

-

-

... More
sand (PWD 307)

0.6

-

5329.09

... More
40mm thick c.c. flooring (PWD 605)

-

-

-

... More
20 mm thick plaster in 1:4 cement &

26.88

-

452.48

... More
Course sand (DSR-13.3.1)

-

-

-

... More
Supply & Febrication of M. S. Steps

24.7

-

72.69

... More
500 mm diameter C.I. cover (medium duty)

-

-

-

... More
the cover to be not less than 58 kg (DSR 19.18.2)

1

-

2514.33

... More
C.I. Cowel (DSR 17.56.1.2)

1

-

343.48

... More
C.I. Plain bend (DSR 17.39.1.2)

1

-

343.48

... More
C.I. Single equal plaing junction (DSR 17.44.1.2)

1

-

552.47

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design

1

-

22220.81

... More
ELECTRICAL WORK

-

-

-

... More
Wiring points for light with 1.5 sqmm.FRLSH PVC insulated single core aluminium condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects.

14

-

579.5

... More
Same as item No.(1) but for fan and light duty exhaust fan.

6

-

637.45

... More
Same as item No.(1) but for 5 Amp plug point

5

-

310.65

... More
Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points.

-

-

-

... More
Addition for light / fan points with modular type switch in place of piono type switch.

20

-

41.8

... More
Add for HPMV/Exhaust fan point with modular type switch in place of piano type switch.

2

-

44.65

... More
Addition for plug points with modular type switch in place of piono type switch.

6

-

78.85

... More
Supply & wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C.

120

-

114.95

... More
Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor.

-

-

-

... More
cable as earth contunity wire etc. complete in all respects.

100

-

141.55

... More
Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor

-

-

-

... More
cable as earth contunity wire etc. complete in all respects.

60

-

193.8

... More
Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.

4

-

133

... More
Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.

2

-

185.25

... More
S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring

-

-

-

... More
conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.

4

-

142.5

... More
Supply fixing of electronic fan regulator(modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.

4

-

491.15

... More
Supply and Ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS: 374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volt 50Hz, 1-ph AC the fan assemble should consist of down rod blades, shackle canopies etc and with double ball breaing system

-

-

-

... More
BEE 5 star rated-1200 mm sweep

4

-

1710

... More
Supply & fixing of LED Tube Light witH Metal heavy duty Box type batten light fitting 1 x 22 watt suitable for upto 1X22W LED Polycarbonate tube light complete including tube etc on surface complete in all respects.(CAT: AAA)

6

-

1130.5

... More
Supply and fixing of flush/surface mounting distribution boards without MCB with additional metal door complete in all respects.

-

-

-

... More
4 Way TPN

1

-

3429.5

... More
Supply and fixing of 240 volts 'L' series miniature circuit breaker 6 Amp. To 32 Amp. (10 K A ) in existing MCB, DB complete with connections as required. (CAT: A)

-

-

-

... More
6 - 32 amps.

3

-

247

... More
Supply fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A)

-

-

-

... More
6 to32 Amp. 4P MCB (10 KA)

3

-

1520

... More
Supply and fixing of power plug with 15A/250 V flush type modular switch and 5 Pin 15 A/250 Volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T & P etc required for proper completion of work.

6

-

323

... More
Supply and fixing Single Pole MCBS Blanking Plate complete in all respects.

5

-

23.75

... More
Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive &

-

-

-

... More
conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.

1

-

9538

... More
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects.

25

-

85.5

... More
Supply and fixing of one number 8 SWG G.I wire in 15mm dia. G.I pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site.

20

-

190

... More
Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size.as per direction of Engineer-Incharge.complete in all respect The armouring of the cable shall be properly connected with the earth conductor by clamps etc.

-

-

-

... More
16 sqmm 4 core

20

-

325.85

... More
Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge.

-

-

-

... More
16 sqmm 4 core

2

-

82.65

... More
Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.

-

-

-

... More
16 Sq.mm

2

-

19.95

... More
S & F of 40 Amp TP MCB (10KA) C Curve.

1

-

1691

... More
Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required

-

-

-

... More
300mm sweep.

2

-

1676.75

... More
Supply and erection of 9watt LED Bulb including connections etc. complete as required

6

-

237.5

... More
GST extra As per Applicable

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.