Uttar Pradesh Projects Corporation Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Projects Corporation Limited - UPPCL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date7 Dec 2024
Closing Soon30 Dec 2024
Tender Amount₹ 10,37,33,799.49 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)

342.31

4978

1704272.49

... More
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.

169.22

1552

262664.98

... More
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement:2 coarse sand) to match the existing floor. With Chlorpyriphos/ Linadane E.C. 20% with 1% concentration.

1820

226

412430.2

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). All works upto plinth level (Plinth beam)

159.98

6611

1057682.17

... More
As in item 6 above but in R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete).

629.86

6611

4164218.61

... More
As in item 6 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. All works upto plinth level

42.35

6611

279990.25

... More
M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.

91.63

5212

477649.78

... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 13mm nominal size)

-

-

-

... More
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

100.06

106

10688.41

... More
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.

1206.99

7882

9514122.81

... More
15 mm thick plinth plaster [1 cement : 4 coarse sand]

85.18

300

25634.07

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete

564.32

286

161745.4

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts

356.1

702

250192.3

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick

1634.03

615

1005516.7

... More
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (a) Ground Floor

3

8409

25227.36

... More
(b) First Floor

8.91

8409

74925.26

... More
(c) Terrace Floor

1.11

8409

9334.12

... More
As in item no. 1 above but for slabs (Using 1:1.5:3 Mix concrete). (a) Ground Floor

276.53

8409

2325373.95

... More
(b) First Floor

257.94

8409

2169048.41

... More
(c) Terrace Floor

49.9

8409

419615.09

... More
As in item 1 but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete). (a) Ground Floor

168.64

8409

1418114

... More
(b) First Floor

159.72

8409

1343104.65

... More
(c) Terrace Floor

31.36

8409

263710

... More
As in item 1 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. (a) Ground Floor

102.73

7932

814873.88

... More
(b) First Floor

98.37

7932

780289.53

... More
(c) Terrace Floor

33.46

7932

265411.08

... More
Brick work in super-structure above plinth level up to floor two level (up to two storeys ) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. 1:6 (1 cement : 6 coarse sand) (a) Ground Floor

154.71

6655

1029647.65

... More
(b) First Floor

380.19

6655

2530293.71

... More
(c) Terrace Floor

152.18

6655

1012809.64

... More
Brick in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.(a) Ground Floor

399.9

821

328461.86

... More
(b) First Floor

575.29

821

472520.19

... More
(c) Terrace Floor

130.09

821

106850.72

... More
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (a) Ground Floor

961.49

7882

7578964.15

... More
(b) First Floor

917.26

7882

7230320.3

... More
(c) Terrace Floor

223.02

7882

1757959.61

... More
15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. (a) Ground Floor

1694.85

288

489726.91

... More
(b) First Floor

2628.06

288

759377.94

... More
(c) Terrace Floor

494.19

288

142796.2

... More
12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 coarse sand. (a) Ground Floor

961.99

251

241623.03

... More
(b) First Floor

1317.16

251

330831.08

... More
(c) Terrace Floor

1158.71

251

291033.19

... More
Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required. (a) Ground Floor

368.78

57

21131.09

... More
(b) First Floor

974.55

57

55841.72

... More
(c) Terrace Floor

155.81

57

8927.91

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm (a) Ground Floor

310.63

3754

1166108.13

... More
(b) First Floor

670.11

3754

2515599.64

... More
(c) Terrace Floor

120.36

3754

451832.64

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm (a) Ground Floor

43.79

3754

164388.1

... More
(b) First Floor

62.84

3754

235901.99

... More
(c) Terrace Floor

32.77

3754

123018.91

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Marbonate/Johnson or equivalent) (a) Ground Floor

39.25

1135

44563.67

... More
(b) First Floor

742.07

1135

842531.44

... More
(c) Terrace Floor

22.15

1135

25148.67

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm(Marbonate/Johnson or equivalent) (a) Ground Floor

8.1

1186

9608.71

... More
(b) First Floor

66.2

1186

78530.41

... More
(c) Terrace Floor

21.94

1186

26026.54

... More
25mm thick KOTA stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete with base of cement mortar for 10 sqm. Ground Floor

17.08

1423

24320.9

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (FLOORING) (a) Ground Floor

8.6

801

6892.47

... More
(b) First Floor

72.96

801

58473.79

... More
(c) Terrace Floor

5.19

801

4159.53

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (a) Ground Floor

35.36

926

32768.82

... More
(b) First Floor

261.14

926

242003.66

... More
(c) Terrace Floor

21.11

926

19563.06

... More
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor).

256.02

448

114927.38

... More
Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. (100 mm C.C. Floor with Trimixing)

1569.1

592

929064.11

... More
2 cm thick cement plaster in dado/ skirting in 1:2 consisting of one part of cement and 2 part of approved coarse sand laid in panels, finished with 3mm floating coat of neat cement and marble dust in ratio of 5:1 including supply of all materials labour T & P etc. required for proper completion of the work.

40.51

483

19601.98

... More
Providing and fixing of Flush doors commercial quality conforming to I.S. 2202 part-I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges, bolts locks, handles spring fitting with necessary screws to be supplied departmentally. 35 mm thick (a) Single leaf

80.33

1748

140476.28

... More
(b) Double leaf

56.07

1826

102424.19

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

136.4

337

46092.29

... More
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I)

272.79

349

95301.91

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) Analyses rate

340.96

5350

1824214.42

... More
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).

2386.72

466

1113524.22

... More
Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and irection of Engineer-in-charge.

312.75

508

159092.8

... More
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats. (For Internal wall surface & ceiling)(Asian Paint or equivalent) (a) Ground Floor

3338.56

118

394551.02

... More
(b) First Floor

4371.61

118

516636.87

... More
(c) Terrace Floor

750.36

118

88677.54

... More
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm (Asian Paint or equivalent) (a) Ground Floor

961.99

163

157218.03

... More
(b) First Floor

1317.16

163

215263.46

... More
(c) Terrace Floor

1158.71

163

189367.98

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (a) Ground Floor

4300.56

114

490521.87

... More
(b) First Floor

5688.77

114

648861.11

... More
(c) Terrace Floor

1909.06

114

217747.38

... More
Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.

59

198

11705.6

... More
Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .

59

427

25222.5

... More
Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm

59

342

20178

... More
Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm

118

171

20178

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

1884.35

1231

2320087.09

... More
Construction of drain alongwith apron.

284.47

1074

305520.78

... More
Providing & laying of light cinder filling under floor of toilets & other sunken roofs.

39.03

2391

93346.88

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

198.49

450

89515.02

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.

4162.98

564

2350127.1

... More
Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)

10.89

5758

62707.12

... More
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment

334.14

772

257979.47

... More
Providing and fixing ISI marked flush door shutters (For Cupboard) conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (a) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws. Both Side Laminated

103.85

2759

286548.11

... More
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).

19.2

1249

23985.6

... More
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge.

5.4

5505

29731.64

... More
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.

4

6114

24458.56

... More
38mm thick wood block flooring of first class teak wood laid over 25mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10mm nominal size) to be paid separately coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm. including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete.

73.81

8785

648457.02

... More
Providing and fixing of wooden railing including top handrail complete in all respect.

37.32

12824

478605.86

... More
Providing & laying of light cinder filling under floor of toilets & other sunken roofs.

27.64

2391

66105.76

... More
Brick work in super-structure above plinth level up to floor two level ( up to two storeys ) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms.

1.77

6655

11779.95

... More
MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings.

1882.07

123

232435.65

... More
Supply and Installation of polycarbonate multi-layered system, a complete assembly of extruded multilayer UV protected polycarbonate panels. Co-extruded UV protected polycarbonate panel system of min 18 mm thick panel of minimum 1200 mm width for bigger spans and minimal junctions for better performance. Panels shall have minimum seven layers Within translucent clear and opaque combination to achieve required Lux Levels of light and angular daylight throughout day with better shading and ambient temperature with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical offset standing seam at both sides of the panel. Panels have to be fixed on Purlin with snap on connectors with grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate Panel which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 2.0 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings.Approved Make: DPI Daylighting

53.77

4275

229866.75

... More
Supply &Fixing of Aluminium sun Louvers of 45 Degree System powder coated for gable end of building of which fins will be 100 mm x70 mm having wall thickness to be fixed to ms Sub Frame of starheadself taping screws .The job includes cutting of louver fins in desired sizes and installed at desired locations the fins will be placed at an interval of 125 mm centre to centre to give firm funish in line and level . The complete system to be installed to the ms Sub-frame attached to the building with help of necessary self tapingscrew . The Cost of MS Frame to be paid Separately .Complete work with all material ,labour,cartage , lead lift ,up vat complete.

9

5557

50017.5

... More
Mild steel or iron work of Heavy section (Lockup)

957.6

126

120801.24

... More
Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.

25.2

165

4167.07

... More
EXPANSION JOINTS-Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap

97.6

4672

456004.77

... More
Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering rragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or eterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) Roof Joint of 100 mm gap

48.8

4374

213491.22

... More
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. Material shall conform to ASTM 6063.) Wall Joint of 100 mm gap

60.8

3877

235769.63

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick

4350.23

751

3269806.88

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick

3645.71

615

2243424.11

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts

1954.92

702

1373507.24

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.

14

10962

153475.7

... More
Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

13

1935

25167.87

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia

13

75

987.22

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia

1

85

85.29

... More
Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

13

1175

15277.86

... More
Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required: Range of two half stall urinals with 5 litre PV.C. automatic flushing cistern.

2

13162

26324.42

... More
Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade

12

2961

35536.92

... More
Providing and fixing PTMT Bottle Trap for Wash basin and sink Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms

13

274

3569.15

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.

13

123

1599.52

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. CP Brass fittings

2

518

1036.32

... More
Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore

40

71

2857.6

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore

13

370

4815.33

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15 mm nominal bore

13

583

7591.22

... More
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore

18

419

7555.5

... More
Providing and fixing C.P. brass shower rose with 15 or 20mm inlet 150 mm diameter

2

162

325.02

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15mm nominal bore

18

490

8820.36

... More
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm

105

271

28494.9

... More
Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 100 mm dia

300

705

211536

... More
Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm

200

275

55166

... More
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Bend

25

109

2747.25

... More
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe

25

96

2409.25

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

18

39

719.64

... More
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

55

271

14925.9

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.

18

217

3923.82

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. (a) 20mm dia nominal outer dia pipes

800

392

314336

... More
(b) 25mm dia nominal outer dia pipes

850

458

389674

... More
(c) 32mm dia nominal outer dia pipes

450

540

243153

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall (a) 15 mm nominal outer dia Pipes

150

209

31443

... More
(b) 20 mm nominal outer dia Pipes

300

244

73452

... More
(c) 25 mm nominal outer dia Pipes

450

293

132066

... More
(d) 32 mm nominal outer dia Pipes

450

379

170617.5

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (a) 20 mm nominal outer dia Pipes

575

392

225929

... More
(b) 25 mm nominal outer dia Pipes

390

458

178791.6

... More
(c) 32 mm nominal outer dia Pipes

100

540

54034

... More
Providing and fixing gun metal gate valve with wheel of approved quality. (a) 25mm dia nominal bore

18

454

8188.2

... More
(b) 32mm dia nominal bore

12

504

6048.12

... More
(c) 40mm dia nominal bore

9

603

5434.02

... More
Providing and fixing brass stop cock of approved quality. b) 20 mm nominal bore+B334

6

277

1662.9

... More
Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Capcity in Per Liters

30000

8

241200

... More
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm.

150

257

38607

... More
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 100mm diameter

150

324

48633

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design 100mm dia SW pipe

150

705

105768

... More
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes

150

406

61005

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. RCC Pipes

150

543

81468

... More
Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With Sewer bricks conforming to IS : 4885

5

1981

9909.6

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line

14

9333

130672.08

... More
Extra for depth for manholes: Size 90x80cm with FPS bricks class I).

10

6450

64502.9

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar

12

398

4777.32

... More
Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes. a) 110mm dia P.V.C. pipe

400

579

231800

... More
b) 90mm dia P.V.C. pipe

334

484

161823

... More
Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90 mm

6

256

1539

... More
Providing and fixing terminal guard. a) 110mm

8

76

608

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.

-

-

-

... More
110mm bend

20

209

4180

... More
90 mm bend

8

194

1558

... More
Coupler

-

-

-

110

142

15675

50

133

6650

... More
Single tee with door

-

-

-

... More
90x90x90 mm

24

232

5586

... More
110x110x110 mm

20

318

6365

... More
Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to15 mm nominal bore

5

1206

6032.5

... More
Providing and fixing clean out plug 110 mm dia.

7

128

897.75

... More
Providing and fixing on wall face unplasticised-Rigid PVC pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 160mm dia Under floor

45

1073

48307.5

... More
Providing and fixing pvc Inlet fitting with 2 inlets 80 mm size fabricated from 110 mm dia PVC pipes(approx. length=150mm to 300mm) and fixed to PVC trap with joint and set in cement concrete as per standard drawing complete.

40

712

28500

... More
Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as per design. With FPS bricks

8

7960

63683.52

... More
Supplying, Installation, Testing & Commissioning of Electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520. (b) Suitable HP Squirrel cage indution motor, TEFC type synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, confirming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 450 lpm at 35 m head

1

65788

65788.25

... More
Providing, laying, testing & Commissioning of 'B' class heavy duty MS pipe confirming to IS 1239 including welding, fittings like elbows,tee, flanges,tapers,nut bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 100 mm dia

200

1311

262228

... More
Supplying & fixing single headed internal yard hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal

4

5835

23341.04

... More
Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 100 mm dia

1

5088

5088.11

... More
Providing, installation, testing and commission of non-return valve of following sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 100 mm dia

1

8433

8433.12

... More
Supplying & fixing orifice plate made out of 6 mm thick stainless steel(grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required:

2

1008

2016.32

... More
Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: Gun Metal

8

3970

31760.4

... More
Supplying & fixing First-aid hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required.

-

-

-

... More
20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585

-

-

-

... More
20 mm nominal internal dia gun metal globe valve & nozzle.

-

-

-

... More
Drum and brackets for fixing the equipments on wall.

-

-

-

... More
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.

-

-

-

4

6620

26482.28

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal

4

1843

7375.36

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc as required.

1

1179

1179.87

... More
Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018

4

8645

34580

... More
Supply & fixing of CO2 type fire extinguisher, 6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018

4

18905

75620

... More
Supplying, installation, testing & commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices(including detector) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memroy(EPROM), power supply(230+-5% V, 50hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall to have facility to connect printer to printout log and facikity to seamless integration with analog/digital voice evacuation system(which is part of the schedule of work under SH:PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specifications. Two Loop Panel

1

182571

182571.3

... More
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.

58

2181

126507.28

... More
Supplying, installation, testing & commissioning responce indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.

48

210

10110.24

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required.

1

2495

2495.59

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

6

2954

17725.56

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.

6

2675

16054.2

... More
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.

6

4380

26283.84

... More
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.

6

1221

7326.48

... More
Supplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

3900

273

1068522

... More
Supplying & laying 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.

300

40

12135

... More
Supply/Fixing of self illuminated "EXIT" sings made out from not less than 4 mm of transparent acrylic sheet of 300 x 150 mm size with self illuminated plastic words of 100 mm height suspended from ceiling by means of M.S. chain or fixed of the walls as required and as directed at site..(MAKE : Agni Suraksha (ASES) / Securiton-aka /System Sensor)

6

4037

24225

... More
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. (Civil DSR 2023)

300

268

80628

... More
Supplying & fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal

4

5835

23341.04

... More
Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 100 mm dia

1

5088

5088.11

... More
Providing, installation, testing and commission of non-return valve of following sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 100 mm dia

1

8433

8433.12

... More
Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: Gun Metal

4

3970

15880.2

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal

4

1843

7375.36

... More
Supplying & fixing of Fire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required. for suitable dia MS pipe connection conforming to IS 904 as required: 2 way-100 mm dia M.S. Pipe

1

5145

5145.35

... More
Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 1239/3589 i/c fitting like elbows,tee,flanges,tapers,nut bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as support, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia

300

2078

623580

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C

365

1102

402518.35

... More
Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed midium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

130

654

85125.3

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

6

1192

7152.54

... More
Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

32

254

8156.8

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (a) 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire

450

209

94441.5

... More
(b) 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire

300

335

100512

... More
(c) 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire

200

435

87002

... More
(d) 4 x 6 sq.mm. + 2 x 6 sq.mm. earth wire

450

575

258943.5

... More
(e) 4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire

150

766

115048.5

... More
(f) 4 x 16 sq.mm. + 2 x 6 sq.mm. earth wire

145

1041

151052.3

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm

500

110

55335

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

121

281

34074.81

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

7

30

213.64

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (a) 1 or 2 Module

45

101

4567.5

... More
(b) 3 Module

135

115

15557.4

... More
(c) 4 Module

10

120

1205.8

... More
(d) 6 Module

15

138

2083.5

... More
(e) 8 Module

20

161

3220.6

... More
(f) 12 Module

15

207

3113.7

... More
Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. (a) 5/6 amps switch

90

78

7074

... More
(b) 2 Way 5/6 amps switch

6

112

677.76

... More
(c) 15/16 amp switch

40

119

4762

... More
(d) 3 pin 5/6 amp socket outlet

60

93

5586.6

... More
(e) 6 pin 15/16 amp socket outlet

30

150

4510.5

... More
(f) Telephone socket outlet

2

112

225.92

... More
(g) TV antenna socket outlet

2

112

225.92

... More
(h) DATA outlet

10

584

5842.5

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

2

75

151.1

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

3

554

1664.49

... More
Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. (a) 2 Pair

200

29

5800

... More
(b) 10 Pair

45

142

6412.5

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable

90

73

6593.4

... More
Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

121

210

25486.23

... More
Installation of exhaust fan in the existing opening , including making good the damage, connection, testing commissioning etc. as required. (a): Up to 450mm sweep

9

343

3090.87

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.

9

157

1421.82

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

45

35

1614.15

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan

121

2083

252099.87

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

365

90

33149.3

... More
Supply of recess/Surface mounting round 12 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respec.

10

1567

15675

... More
Supply of LED Tube Light 40 watt Polycarbonate tube light complete including tube etc suitable for both wall & surface complete in all respects.

148

2071

306508

... More
Supply of LED Tube Light 20 watt Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.

123

1121

137883

... More
Supply of 7W Bulkhead light fixture with specification complete as per architectural design

14

902

12635

... More
Supply of 36W 2'X2' Square light fixture with specification complete as per architectural design.

62

3087

191425

... More
Supply of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitbale for 70 Watt Conforming to IP 65/66 protection complete in all respect.

8

4332

34656

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 4 way Double door (4 + 12)

2

3122

6244.34

... More
(b) 6 way Double door (4 + 18)

6

3796

22776.3

... More
(c) 8 way Double door (4 + 24)

2

4553

9107.76

... More
Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (a) 4 way Double door (4 + 12)

1

5732

5732.99

... More
(b) 8 way Double door (4 + 12)

1

7757

7757.71

... More
Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. (a) For 4 way, Double door TPN MCBDB

2

824

1648.46

... More
(b) For 6 way, Double door TPN MCBDB

4

857

3431.24

... More
(c) For 8 way, Double door TPN MCBDB

2

1022

2045.32

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

150

195

29307

... More
Supplying and fixing 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63A 4P

6

3382

20292

... More
(b) 40A 4P

1

3382

3382

... More
(c) 100A 4P

1

3382

3382

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

32

9

317.44

... More
Suplly and burring of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) Make: As approved in U.P.P.W.D & C.P.R.I. all respects.

2

8132

16264

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

10

886

8868.2

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

85

186

15828.7

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

125

53

6677.5

... More
Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. (a) 300 sqmm 3.5 core

220

1472

323950

... More
(b) 70 sqmm 3.5 core

150

456

68400

... More
(c) 25 sqmm 3.5 core

200

342

68400

... More
(d) 16 sqmm 4 core

45

280

12611.25

... More
(e) 10 sqmm 4 core

125

251

31468.75

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (a) 3½ X300 sq. mm (50mm)

4

889

3556.44

... More
(b) 3½ X 70 sq. mm (38mm)

4

357

1428.68

... More
(c) 3½ X 25 sq. mm (28mm)

12

238

2866.56

... More
(d) 4 X 16 sq. mm (28mm)

4

235

943.28

... More
(e) 4 X 10 sq. mm (25mm)

16

205

3284.8

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm

370

34

12705.8

... More
Supply, Installation, Testing and Commissioning of 250mm size PVC exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge.

9

3148

28334.7

... More
S/f of 30 pair Telephone Tag Block for Floors and building with Krone connectors , with connection and punching of same

2

8217

16435

... More
LT PANEL

-

-

-

... More
Design, Supply, installation, testing and commissioning of indoor/outdoor floor mounted/ wall mounted, IP43/IP65, IEC 61439/IS 8623, factory built, modular, sectionalised, compartmentalized, extendable type HT/LT cubicle panel of suitable size suitable for operation on 33/11/0.433/0.415 kV, 50 Hz AC 3 phase supply system fabricated from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process or better before painting for surface treatment and powder coated in approved shade, with suitable electrolytic grade high conductivity bus bars extensible, DMC/ SMC (whichever is superior) bus bar supports, with short circuit withstand capacity as mentioned ,bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, including providing and fixing following switch gears as per SLD ,technical specifications etc.complete in all respect so as to fulfill all as required.

-

-

-

... More
LT Panel The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Incoming : 1Nos 400 Amp. 4P MCCB of 36kA Breaking capacity 1Nos 400 Amp. 4P ATS Metering : 1 Set of CT's one of 250/ 5Amp ratio for Multifunction Meter 1 Set of CT's one of 250/ 5Amp ratio 50/51/86/95 1 Nos. Set of Phase Indication Lamp. 1 Nos. of class-III Type SPD Bus Bar : 400 Amp.TPN aluminimum bus bar of suitable length.50KA Outgoing : Phase indication lamps on each outgoing to be provided. 03 No.63 Amp 4P MCCB. (25 KA) 03 No.63 Amp 4P MCB. (10 KA) 04 No.40 Amp 4P MCB. (10 KA) "Panel described as above"

1

294167

294167.5

... More
Lift Panel The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Incoming : 1 Nos. 100 Amp. 4P MCCB of 25kA Breaking capacity Metering : 1 Set of CT's one of 100/ 5Amp ratio for Multifunction Meter 1 Set of CT's one of 100/ 5Amp ratio 50/52 1 Nos. Set of Phase Indication Lamp. 1 Nos. of class-III Type SPD Bus Bar : One (1) No.200 Amp.TPN aluminimum bus bar of suitable length.25KA Outgoing : Phase indication lamps on each outgoing to be provided. 02 No.63 Amp 4P MCCB. (25 KA) 02 No.63 Amp 4P MCB. (10 KA) "Panel described as above"

2

119367

238735

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (a) 100 mm wide x 50 mm depth x 1.6 mm thickness.

50

510

25528.5

... More
(b) 300 mm width X 50 mm depth X 1.6 mm thickness

20

734

14698.8

... More
(c) 450 mm width X 50 mm depth X 2.0 mm thickness

10

1011

10112.1

... More
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mm diameter

200

257

51476

... More
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 1.50 m to 3.00 m depth Pipes 80 mm to 300 mm diameter

60

350

21003.6

... More
Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter

150

52

7899

... More
Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth 1.5 to 3.00 meter

50

59

2982

... More
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. (a) 150 mm. dia. RCC Pipes

150

406

61005

... More
(b) 250 mm. dia. RCC Pipes

50

657

32882.5

... More
Providing and laying cement concrete 1:5:10(1cement:5coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design (a) 150 mm. dia.

150

543

81468

... More
(b) 250 mm. dia.

50

743

37161.5

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line

2

9333

18667.44

... More
Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5

1

6450

6450.29

... More
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line

4

24015

96060.4

... More
Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5

1

7736

7736.71

... More
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

20

404

8093.8

... More
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) (a) 80mm nominal bore.

150

761

114204

... More
(b) 65mm nominal bore.

50

655

32765.5

... More
Supplying and fixing of specials for pressure pipe.

1

14696

14696.87

... More
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 65mm nominal bore.

3

1273

3819.9

... More
Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

13811

13811.2

... More
Constructing brick masonry open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: (a) 250cm drain 300 cm average depth

100

1554

155430

... More
(b) 300cm drain 450cm average depth

150

2076

311401.5

... More
Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. (a) In all kind of soil upto 1.5m depth

37.13

129

4816.87

... More
(b) In all kind of soil upto 1.5m to 3.0m. depth

39.61

222

8809.26

... More
Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 20mm nominal size)

2.48

5758

14280.41

... More
Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand)

18.48

5387

99552.68

... More
Reinforced cement concrete work in slab with 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20mm normal size).

2.29

8409

19256.88

... More
Reinforcement for R.C.C. work including, straightening, cutting bending binding and placing in position complete.

180

78

14090.4

... More
Centring and shuttering including struting , proping etc and removal of form for slab.

22.92

677

15533.11

... More
15mm cement plaster on rough side of mix 1:4 (1 cement : 4 course sand)

80.33

300

24174.51

... More
Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.

12

398

4777.32

... More
Providing and fixing C.I. tee at the inlet and outlet of septic tank.

2

648

1297.9

... More
Providing & fixing 75mm dia vent pipes.

1

763

763.58

... More
Providing & fixing of 75mm dia cast iron terminal guard.

1

249

249.01

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. (a) M.D. -10- Circular shape 500mm internal diameter

2

857

1714.04

... More
(b) L.D. -2.5- Circular shape 450mm internal diameter

4

854

3419.52

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks

1

19632

19632.79

... More
Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (a) In all kind of soil upto 1.5m depth

32.07

129

4160.44

... More
(b) In all kind of soil upto 1.5m to 3.0m. depth

32.07

140

4494.29

... More
(c) In all kind of soil upto 3.0m to 4.5m. depth

25.58

158

4052.38

... More
Providing and laying in position cement concrete of specified grade excluding the ccost of centering and shuttering -All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).

1.6

5758

9213.17

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)

33.25

4978

165543.11

... More
Reinforced cement concrete work inbeams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, intels, bands plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size)

2.14

6946

14866.19

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tnsile steel bars.

168

78

13241.76

... More
Centring and shuttering including struting , proping etc and removal of form for : Suspended floors, roofs, landings, balconies and access platform.

-

-

-

... More
15 mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 coarse sand)

74.78

370

27688.04

... More
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar

24

398

9554.64

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter

4

857

3428.08

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually.

50

517

25864

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia

50

590

29507.5

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

7.07

1103

7801.6

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

7.07

1124

7948.66

... More
Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

7.07

1124

7948.66

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge.

2

1479

2959.32

... More
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter.

350

257

90083

... More
Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 150mm diameter S.W. Pipe

300

508

152562

... More
Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. b) 200mm diameter S.W. Pipe

50

709

35460

... More
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) upto haunches of S.W. Pipes including bed concrete as per standard design. a) 150mm diameter S.W. Pipe

300

543

162936

... More
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) upto haunches of S.W. Pipes including bed concrete as per standard design. b) 200mm diameter S.W. Pipe

50

638

31921

... More
Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. a) Inside size 60x60 cm & 90 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg.

40

6470

258834

... More
OPEN SEWERS & STORM WATER DRAINAGE LINES GRID (ON EITHER SIDE OF THE ROADS OR BETWEEN ROAD EDGE AND PLATFORMS, LEADING TO RWH RECHARGE PIT. UNDERGROUND SEWER LINE AT DEPTH OF 1.5 TO 3 MTR.WITH 600 MM DIA RCC NP-3 HUME PIPE

-

-

-

... More
COST OF SEWERAGE WORKS

-

-

-

... More
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mm diameter

500

257

128690

... More
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 1.50 m to 3.00 m depth Pipes 80 mm to 300 mm diameter

300

350

105060

... More
Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter

500

52

26330

... More
Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth 1.5 to 3.00 meter

300

59

17892

... More
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. (a) 150 mm. dia. RCC Pipes

500

406

203350

... More
(b) 250 mm. dia. RCC Pipes

300

657

197295

... More
Providing and laying cement concrete 1:5:10(1cement:5coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design (a) 150 mm. dia.

500

543

271560

... More
(b) 250 mm. dia.

300

743

222969

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line

20

9333

186674.4

... More
Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation

2

6450

12900.58

... More
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line

4

24015

96060.4

... More
Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation

1

7736

7736.71

... More
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

50

404

20234.5

... More
COST OF EXTERNAL WATER SUPPLY WORKS

-

-

-

... More
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) (a) 80mm nominal bore.

500

761

380680

... More
(b) 65mm nominal bore.

300

655

196593

... More
Supplying and fixing of specials for pressure pipe.

1

57727

57727.3

... More
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 65mm nominal bore.

6

1273

7639.8

... More
Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

13811

13811.2

... More
DRAINS -III

-

-

-

... More
Constructing brick masonry open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: (a) 250cm drain 300 cm average depth

375

1554

582862.5

... More
(b) 300cm drain 450cm average depth

215

2076

446342.15

... More
Transportation Charges of drilling equipment including assembly and other material as required.

1

9500

9500

... More
Drilling of 675 mm. dia by rotary machine

100

1235

123500

... More
Supply & laying of 350 mm. dia housing pipe (8 mm. thick)

40

2185

87400

... More
Supply & laying of 200 mm. dia blind pipe (8 mm. thick)

25

1710

42750

... More
Supply & laying of 200 mm. dia slotted pipe (8 mm. thick)

35

1710

59850

... More
Supply & fixing of 350 mm. dia Socket

8

1330

10640

... More
Supply & fixing of 200 mm. dia Socket

11

760

8360

... More
Supply & fixing of 200 mm. dia Bail plug

1

1140

1140

... More
Supply & fixing of 350 mm. dia well cap

1

1710

1710

... More
Supply & fixing of 350x200 mm. dia reducer.

1

3610

3610

... More
Supply & fixing of 350 mm. dia housing clamp

1

1900

1900

... More
Supply & Filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I.

32

2185

69920

... More
Development by air compressor including Transportation.

25

1710

42750

... More
Development by O.P. Unit including Transportation.

35

1425

49875

... More
Supply of KSB make submersible pump set model BPD 302/4+UAMI 150/6/22-203 (S/D) suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition. A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm. B - Total Head of pump set 45 m.

1

59850

59850

... More
Supply and fixing of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm.

55

171

9405

... More
Supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having L&T of qul. Male switch fuse unit with HRC fuses, Ameter, Boltmeter, Selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of Jyoti or eq. Air break Star- Delta motro starter suitable for above submersible pump set.

1

17100

17100

... More
Supply of 80mm dia M.S. column pipe of class 'C' both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements.

55

1710

94050

... More
Supply of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc.

2

1330

2660

... More
Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make.

1

6175

6175

... More
Supply of 80mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make.

2

7600

15200

... More
Supply of C.I. double flanged bend of 80mm dia i/c cost of material and labour.

1

1377

1377.5

... More
Supply of 80mm dia C.I. tee heavy quality i/c cost of material.

1

5700

5700

... More
Supply of Guru/Fibing or equivalent make pressure gauge.

1

4750

4750

... More
Erection & commissioning of pumping plants complete along with electric wiring.

1

14250

14250

... More
Supply of steel wire rope of 1/2" size

55

47

2612.5

... More
S/B of 600mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead on one no. 8 to 10 SWG GI wite in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. , pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of E/I complete in all respects as per drawing.

1

4085

4085

... More
S/F of one number 8 to 6 SWG G.I. wire in 15mm dia G.I. Pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. T&P other material required for proper completion of the work as directed at site.

8

190

1520

... More
S/F of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E/I complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm x 4 core

40

209

8360

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (D.S.R. 2.6.1)

240.33

129

31178.01

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (D.S.R. 4.1.8)

131.09

4978

652663.03

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) (D.S.R. 6.1.2)

39.08

5212

203716.61

... More
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) D.S.R. 4.1.3

73.56

5758

423575.4

... More
Providing and laying in position bitumen hot sealing compound for expansion joints etc. DSR- 16.46.1 Using grade 'A' sealing compound.

327.73

6

2071.25

... More
COST OF INTERLOCKING TILES

295.2

1345

397167.98

... More
Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment).

150

281

42229.5

... More
Carrigae of sludge upto 5 K.M.

150

179

26938.5

... More
Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm

75

306

22975.5

... More
Carrigae of manure upto 5 K.M.

75

179

13469.25

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.

225

35

7875

... More
Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately).

225

50

11279.25

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately). Holes 0.9 m dia. and 0.90 m deep.

105

321

33733.35

... More
Providing & stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge.

15

622

9336.6

... More
Providing & stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35cm as per direction of the officer-in-charge.

15

526

7900.2

... More
Supply and stacking of Plumeria alba plant of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge.

15

114

1723.65

... More
Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge

15

57

861.9

... More
Supply and stacking of Cassia fistula (Amaltash) plant of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

15

62

933.6

... More
Supply and stacking of Michelia champa (Golden Champa)plant of height 90-105 cm. in earthen pots of size 25 cm as per direction of the officer-incharge.

15

86

1292.7

... More
Supply and stacking of Lagerstroemia thorelli plant of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.

15

114

1723.65

... More
Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf.

1400

16

23730

... More
COST OF EARTH FILLING ON SITE (L.S.)

1

190000

190000

... More
Acoustical Wall Paneling Providing and Fixing Armstrong Channeled Woodworks perforated panels of width 128mm, thickness of 16mm and length 2550 mm, made of a high density particle board substrate with a laminated facing as per the approved shade/ species & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a (“Helmholtz” fluted perforation of 2mm width and 14mm of visible panel / 4mm width and 28mm visible panel) each. The panels shall provide a minimum sag resistance of RH90 and a fire rating class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece. The panels shall be mounted on special aluminum spines using clips provided by Armstrong and approved by the Architect/ Engineer-in-Charge. This wood work shall be provided on walls upto level of 4880 mm from floor level over company made aluminum spines and sandwiching 50 mm thick 24 kg / mtr. density cube rock wool acoustical backing.

215.48

5611

1209198.34

... More
PASSENGER LIFT (8 PERSONS ) ThyssenKrupp, OTIS and Johnson

1

1086864

1086864.41

... More
GST Extra as per applicable

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.