Uttar Pradesh Power Transmission Corporation Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date3 Feb 2025
Closing Date24 Feb 2025
Tender Amount₹ 33,78,000
Costs
EMD
₹ 34,000Document Cost
₹ 1,770Tender Fee
Refer Documents
Summary
Supply & Work Of ( 3x63 ) Mva 132 / 33 Kv Transformers In place Of ( 2x40+1x63 ) Mva 132 / 33 Kv Transformers
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_UPTCL_1001642_1Tender No
E-Tender No.-50/ETC-I/2024-25Tender Authority
Uttar Pradesh Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://https://upenergy.in/upptcl
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Air Conditioner system for 2 Ton Window AC With all accessories and stablizer (Not less then 5KVA Capacity) ( Daikin/ Hitachi/ Voltas make)
7
-
-
... More
UPS 600 VA Line Interactive UPS for office Desktop PCs, Laptops, Routers, Networking Devices with warranty of 02 years (Luminous or any standard make)
2
-
-
... More
Printer Lazer Black & White -Laser jet Pro Mfp M128Fw Monochrome LaserPrinter,Wireless,Print,Copy,Scan,Fax,35-Sheet Adf,Ethernet,Hi-Speed Usb 2.0,Up To 21 Ppm,150-Sheet Input Tray,100-Sheet Output Tray,Black And White (03 Year on site Warranty)(HP/Canon Make)
1
-
-
... More
Desk top Computer - 13th Gen Intel Core i5 27" (68.6cm) FHD,Three-Sided Micro-Edge,Anti-Glare,300 nits, 16GB RAM, 512GB SSD, Intel UMA Graphics, Keyboard and Mouse Combo (Windows 11 Home, MSO 21, Shell White) with 3 Year on site Warranty. (HP / Dell Make)
2
-
-
... More
5 KV Digital Insulation Tester (Megger Make or Equivalent)
1
-
-
... More
Digital Multimeter (4 1/2 Digit) Motwani Make or Equivalent
1
-
-
... More
ERRECTION WORK PART DETAILS :-
-
-
-
... More
Following works are to be carried out at 132 K.V. Sub Station Mohan Road, Lucknow for replacement of 02 No. existing 40 MVA 132 / 33 KV Transformer - II & III (AREVA & ATLANTA Make) by new 2X63 MVA 132 / 33 KV Transformer alongwith associated works against Increasing Capacity including all cost of men, misc. consumables, T&P, Crane, Centrifuging Machine etc. to complete the job satisfactorily :
-
-
-
... More
Erection of 02 No. 63 MVA Transformer RTCC Panel including Shifting from storage place to C&R Room as per direction of site Engineer.
2
-
-
... More
Shifting of Main Tank of 132 / 33 KV 63 MVA Transformer to Plinth from place of storage up to 20 Meter distance including turning of Tank if required.
2
-
-
... More
Additional Shifting of Transformer Tank upto 50 Meter distance (1 Job for every 5 Meter)
50
-
-
... More
Complete Erection of 02 No.132 / 33 KV 63 MVA Transformer including Radiators, Conservator Tank, Bushings, Connecting Pipe Lines, Cooling Fans, Marshaling Box, OTI, WTI, Capilliary Pipes etc.
2
-
-
... More
Top up with fresh Transformer Oil from Transformer Oil Drums in main tank,bushings & conservator of transformer upto required level
2
-
-
... More
Centrifuging / Dehydration of the complete Transformer Oil of Transformer by Ultra High Vacuum Oil Filtration Plant after connecting the Centrifuging Pipes with Oil Tanker to Oil Filtration Plant including taking the BDV Values of Oil and megger values of the Transformer periodically till the required value is achieved, with all cost of Centrifuging Machine, CFM Operator, Lubricants etc.
49000
-
-
... More
Making of 02 No. Additional Delta for Neutral Earthing by due fabrication of 3 No. 3.5 Meter long Electrodes of 36 / 40 mm dia. M.S. Round Bar, its piercing under the ground at equal distance of 1 Meter at 700 mm depth by digging of earth and connecting all the 3 No. Electrodes with 75 mm x 10 mm size M.S. Flat & connecting with existing Earthmat and taking out Riser by due cutting, bending, welding etc. as per Technical Specifications.
4
-
-
... More
Earthing of Main Tank, Marshaling Box, Drive Mechanism, Transformer Neutral etc. of 63 MVA Transformer with the help of 50 x 6 mm / 75 x 10 mm size M.S. Flat, its jointing with already laid Earthmat / Deltas including Additional Delta at 2 places and necessary modification in existing support for Earthing of Neutral Bushing support for its Earthing work and then Painting of Earthing Strips as per technical specifications / standard practice.
2
-
-
... More
Jumpering of HV of New 02 No. 63 MVA Transformers through 120 K.V. LAs with the help of existing / newly prepared ACSR Panther Conductor respectively with associated Terminal Connectors and P.G. Clamps etc. to connect with 132 K.V Bus Bar as per requirement.
2
-
-
... More
Jumpering of LV Bushings of 02 No. 63 MVA Transformers with the help of existing / newly prepared ACSR Twin Moose Conductor respectively with associated Terminal Connectors and P.G. Clamps etc. to connect with 33 K.V. Bus Bars / CTs/LAs.
2
-
-
... More
Connection of the Cables as per new Cable schedule of 63 MVA Transformer & its RTCC Panel at both ends and Control & Relay Panel, Cooling Fans, Marshaling Box etc. using existing Cables including Laying of additional Control Cables (if required), making necessary holes in the Glands Plates or Box wherever required, Supply & Fixing of Cable Glands of appropriate size, providing of Ferrules as per site requirement and Termination and connection of all existing / new Control Cables at RTCC & Transformer End and C & R end as per standard practice & all other associated works as per Technical Specification.
2
-
-
... More
Proper Packing of HV / LV & Neutral Bushings of dismantled 40 MVA Transformer-II & III including proper wrapping with Polythene Sheet in Wooden Crates of new Bushings of 63 MVA Transformer.
2
-
-
... More
Safe Carriage of 33 KV 2000/1250/1 amp. 3 Nos CTs from Transmission Substation in Lucknow (as per availability) to 132 KV Substaation Mohan Road,Lucknow including Loading and Unloading
2
-
-
... More
Erection of 33 K.V. 2000 - 1250 / 1 Amp. CTs as per instruction manual and Technical Specifications including shifting of CTs from Store to Erection site including necessary connection of Cable & Earthing and Jumpering on both sides.
6
-
-
... More
Erection of 120 KV LA & 30 KV LA including erection of ALP structure and connection of earthing with existing MS flat at designated places and jumpering with jack bus as per technical specifications( 1 Job for each set of LA and ALP structure)
6
-
-
... More
Safe transportation of 01 drum of ACSR Moose conductor,02 drum ACSR Panther Conductor & 05 Drum ACCC HTLS Conductor as availability of 220/132 S/S Lucknow to 132 KV S/S Mohan Road including loading and unloading & with help of hydra & Man Power.
4
-
-
... More
Safe Carriage of Oil Tanker 20 KL including loading & Unloading from Transmission Substation in Lucknow (as per availability) to 132 KV Substaation Mohan Road.(Approx distance 20 KM)
2
-
-
... More
Return of Oil Tanker 20 KL including loading & Unloading from 132KV S/S Mohan Road Transmission Substation in Lucknow to 132 KV Transmission Substaation (Approx distance 20 KM)
2
-
-
... More
Sampling & testing of transformer oil at CPRI or any other NABL testing lab including cost of transportation of sample in standard sampling bottle (adequate no. of bottle arranged by contractor) . samples to be taken at following intervals . 1 Before filling in transformer main tank & OLTC -02 samples 2. Before charging -05 samples at top & bottom of main tank & OLTC -3 samples. Following test to be Performed - 1-BDV 2)PPM 3)Tan delta 4) Resistivity 5) Interfacial tension 6) Particle count 7 ) DGA (one job for each sample Note-Any other tests required by T/F manufacturer will be in contractors scope.
6
-
-
... More
Providing and fixing of Protective MS Iron Mesh/ Jali of size (3x3mtr approx) on both side of 63MVA T/f (HV &LV) to protect Radiators from any damage.Work includes proper grouting of MS angle support stand/structure adjustable to radiator height. Each cell size 01x1.25 inch and thickness 04mm.
4
-
-
... More
Supply and fixing of new generation energy saving environment friendly long life versatile pressure die casting aluminium outdoor high beam flood light with high power of LED street light luminaries 250 watt of havells/CGL /any standard make. Transportation upto site, insurance etc. and any other job requested to properly execute the complete work.
24
-
-
... More
Supply and fixing of junction box on gantry structure of size 200mmx200x150mm made of MS sheet of 16 gauge duly powder coated in side fixing 1no. 6amp MCB ,1no. TB of 1no. terminal, and 1no. 16amp fuse fixed on MICA sheet and back side MS clampalong with PVC pipe fixing on junction box.half round GI PIPE OD 50mm for mounting the 250 watt LED light upon gantry mounting of 02no. Bracket upon gantry and fixing GI pipe complete with Nut & bolts and washer.
24
-
-
... More
Supply and fixing of half round GI PIPE OD 50mm for mounting the 250 watt LED light upon gantry mounting of 02no. Bracket upon gantry and fixing GI pipe complete with Nut & bolts and washer.
24
-
-
... More
Following works are to be carried out at 132 K.V. Sub Station Mohan Road, Lucknow for replacement of 02 No. existing 40 MVA 132 / 33 KV Transformer - II & III (AREVA & ATLANTA Make) by new 2X63 MVA 132 / 33 KV Transformer alongwith associated Dismantaling works against Increasing Capacity including all cost of men, misc. consumables, T&P, Crane etc. to complete the job satisfactorily :
-
-
-
... More
Dismantling and Shifting of old 40 MVA Transformer-II & III RTCC Panel from C & R Room including necessary Disconnection of Control Cables including identification of Cables for necessary future connections and Shifting the same at proper place / store as per direction of site Engineer.
2
-
-
... More
Complete safe Dismantling of the accessories of 132 / 33 KV 40 MVA Transformer-II & III (AREVA & ATLANTA MAKE) including Opening of Jumpers, Removal of Earthing, Opening of Cable Connections, Draining out of Transformer Oil up to required level in 209 Ltr. capacity Oil Drums, Removal of Conservator Tank, Pipe Lines, Bushings, Cooling Fans, Marshalling Box, Radiators after Draining of Radiator Oil etc. and Fixing of Blanking Plates on the Radiators, Pipe Lines, Conservator Tank, Turret etc. with proper Stacking. Blanking Plate including Bolts & Nuts shall be provided by the Contractor.
2
-
-
... More
Shifting of Main Tank of 132 / 33 KV 40 MVA Transformer-II & III to storage place from the Plinth up to 20 Meter distance including turning of Tank if required.
2
-
-
... More
Additional Shifting of Transformer Tank upto 50 Meter distance (1 Job for every 5 Meter)
50
-
-
... More
Dismantling of 33 K.V. 800 / 1 Amp. CTs by due Opening of Jumpers, Earthing, Cable Connections, Nut & Bolts etc. and Shifting upto Store / designated place at the Sub Station as per direction of site Engineer.
6
-
-
... More
Dismantling of 120 KV LA & 30 KV LA alongwith ALP structure and proper stacking after opening of jumpers and disconnection of earthing( 1 Job for each set of LA and ALP structure)
6
-
-
... More
Work for shifting of materials from the area (where new open store is to be constucted) to open space & after constuction of new open store, also shifting of inventory/Scrap/Damaged Materials from Open Area of 132 KV Sub-Station Mohan Road, Lucknow to newly constructed open store area. The work includes Loading, Unloading, shifting of following material at Open Space Area and shifting stacking properly New Store Areas as per instruction of J.E (M)/S.D.O (M) with all cost of man power, material and T&P etc. required for the completion of Job.
-
-
-
... More
Auxilary Structure/Tower Part/Main Structure/C.T/P.T/Conductor & Other Loose Item & Scrap (Approx. 435 MT)
435
-
-
... More
Construction of 02 nos. fire hut & 01 No. DG Set hut of size 4000 x 3000 x 2000 mm duly made of GI angle post supports & frame structure covered by 1.5 mm corrugated fiber glass (A.C.) roofing sheet and B.C. platform as per technical specifications with all cost of men, materials, misc. comsumables and T & P etc. required for the job at 132 kV S/S Mohan Road as per details given below:-
-
-
-
... More
Grouting of 04 Nos. 50 x 50 x 6 mm GI angle posts of height 2500 mm grouted upto 500 mm depth with CC mixture in the ratio of 1:2:4. Fabrication, fixing & welding of open hut type GI angle frame structure of size 4000 x 3000 x 2000 mm on above grouted GI angle posts by due cutting,drilling and welding of GI angles of size 50 x 50 x 6 mm which shall be provided by the department.
3
-
-
... More
Fixing & fitting of 1.5 mm red colour corrugated fiber glass (A.C.) roofing sheet to cover the roof of open hut type GI angle frame structure of size 4000 x 3000 x 2000 mm with 'J' hooks,nuts,bolts and washer etc. for each fire hut including fixing of the ridge cap at the top of the open joint of the roof sheet for preventing of seepage of rain water.The joints shall be sealed properly to make them water proof using necassary sealant materials.
3
-
-
... More
Construction of B.C. floor / platform of size 4000 x 3000 x 200 mm for each fire hut with first class brick ballast,cement & sand mixture in the ratio of 1:4:8 and finally 12 mm thick plastering with cement & sand mixture in the ratio of 1:4 including necessary curing etc.
7.2
-
-
... More
Fixing of 02 nos. MS BP sheet board of size 300 x 150 mm in the angle frame structure of each fire hut after due fabrication by cutting,drilling,welding etc. of MS BP sheet including painting of above angle post & frame structures with post office red colour synthetic enamel paint of standard quality in two coats after applying one coat of red oxide primer and writing 'आग ' and 'FIRE' on the MS sheet boards. (01 Job for each fire hut)
3
-
-
... More
Construction of 01 no. Vehicle sheds of size 6000 x 3000 x 2000 - 2500 mm duly made of GI angle post supports & frame structure covered by 1.5 mm corrugated fiber glass (A.C.) roofing sheet as per technical specifications with all cost of men, materials, misc. comsumables and T & P etc. required for the job at 132 kV s/s Mohan Road as per details given below:-
-
-
-
... More
Grouting of 03 nos. 50 x 50 x 6 mm GI angle posts of height 2500 mm and 03 nos. 50 x 50 x 6 mm GI angle posts of height 2000 mm both grouted upto 300 mm plinth with CC mixture in the ratio of 1:2:4. Fabrication, fixing & welding of rectangular GI frame structure of size 6000 x 3000 x 3000 - 3500 mm on above grouted GI angle posts by due cutting,drilling and welding of GI angles which shall be provided by the department for Vehicle shed.
1
-
-
... More
Construction of B.C. floor / platform of size 6000 x 3000 x 200 mm for vehicle shed with first class brick ballast,cement & sand mixture in the ratio of 1:4:8 and finally 12 mm thick plastering with cement & sand mixture in the ratio of 1:4 including necessary curing etc.
3.2
-
-
... More
Fixing & fitting of 1.5 mm green colour corrugated fiber glass (A.C.) roofing sheet to cover the roof of rectangular GI angle frame structure of size 6000 x 2000 x 3000 - 3500 mm with 'J' hooks,nuts,bolts and washer etc. for vehicle shed.The joints shall be sealed properly to make them water proof using necassary sealant materials.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%