Uttar Pradesh Power Transmission Corporation Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender
Civil And Construction
Civil Works Others
Electrical and Electronics
Eprocure
Opening Date6 Jun 2024
Closing Date13 Jun 2024
Tender Amount₹ 11,59,000
Costs
EMD
₹ 12,000Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UPTCL_924155_2Bid Award Id
ViewTender No
T.No. 05/ETCS/2024-25Tender Authority
Uttar Pradesh Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://https://www.upenergy.in/upptcl
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling and lowering down of each phase of 33 KV main bus, single span with the help of suitable hardware fittings and T & P and cutting of one side Panther conductor in existing bus complete in all respect.
3
-
-
Dismantling of structure (ALP-9, ABL-3)
2.23
-
-
Dismantling of 36KV CT/PT/NCT
8
-
-
Dismantling of 36KV LI
2
-
-
Dismantling of 36KV BI
1
-
-
Dismantling of 36KV VCB
1
-
-
Dismantling of 36KV CT/PT JB
2
-
-
Dismantling of 3 ph Reactor oil cooled
4
-
-
Dismantling Capacitor Bank Units (5MVAR each set) incl support frame.
24
-
-
Carriage of structure/materials from Electy. Fabrication unit Naini Prayagraj/other Substation To 132KV S/S Jagdishpur - Amethi.
-
-
-
Sorting, counting, stacking mark wise and head loading of structure on Truck/Trailer (6.85 MT)
1
-
-
Safe carriage loaded structure from Electy. Fabrication unit Naini Prayagraj to 132KV S/S Jagdishpur- Amethi. Distance approx. 180km (6.85 MTX180km=1233MT-KM)
1233
-
-
Unloading of carriage structure from Truck/Trailer its sorting, Counting and proper Stacking at the S/S premises as per directing of supervisioning engineer (6.85 MT)
1
-
-
Erection of following equipments and structure as per drawing instruction manual of various equipments including shifting from store to erection site and other associated work.
-
-
-
Erection of main and auxiliary structure, mast etc. The job consist of shifting of all materials i.e. structure parts, nut bolt, washers etc. from store to site of erection. Erection of structure as per relevant drawing and practices using flat/spring washer with each bolt matching holes. Cutting, notching of members if required shall also be done by contractor without any extra cost to complete the work satisfactorily.
10.2
-
-
Erection of following 33KV 1x10MVAr (Dismantled) & 1x10MVAr(new) Capacitor Bank equipments and 33KV Main Bus (extension) equipments including shifting of materials from store to work site:
-
-
-
33KV PT
3
-
-
PT junction box
1
-
-
33KV LA/ PI
6
-
-
33 KV Line Isolator
4
-
-
33 KV Bus Isolator
3
-
-
33 KV VCB
2
-
-
33 KV CT
6
-
-
CT junction box
2
-
-
Capacitor cells 24 microfarad
48
-
-
NCT
4
-
-
Series Reactor
8
-
-
Fabrication & connection of Moose/Panther & Panther/Panther jumpers complete in all respect.
72
-
-
Laying of 1.1 KV Unarmored copper control cable from various 33KV Capacitor Bank equipments (new & old unit) and new 33KV Main Bus(extension) equipments to C&R Panels.
-
-
-
2xCx2.5 sqmm.
2500
-
-
4xCx2.5 sqmm.
1000
-
-
6C x 2.5 sqmm.
1500
-
-
Erection of Control & Relay panel of New Capacitor Bank.
1
-
-
33KV Capacitor bank bay both sides control cable terminations on CT, CB, PT and control & Relay panel etc. as per drawing including cost of cable glands, lugs and ferrules except control cable complete as per drawing & site requirement.
3
-
-
Stringing of each phase of 33 KV Bus bar (1 x Panther Conductor) for 12mtr span (for capacitor Bank Bus of new 1x10MVAr unit and old 1x10MVAr unit) total 2span, including fitting of tension & suspension clamps, hoisting of insulators, cutting of conductor etc. performing all other associated work to complete the job satisfactorily.
6
-
-
Stringing of each phase of 33 KV Bus bar (1 x Moose Conductor) for 33KV Main Bus(extension) in two span each span 12mtr, including fitting of tension & suspension clamps, hoisting of insulators, cutting of conductor etc. performing all other associated work to complete the job satisfactorily.
6
-
-
Providing & Fixing of 3 Phase L.T. A.C. Supply Cubicals of size 1200×600×500 mm with Hinged Door and Proper Locking Arrangement duly made of 16 SWG M.S. Sheet
and Painted with Grey Colour Synthetic Enamel Paint. The L.T. A.C. Supply Cubical should be Fitted with 3 Nos. 100 Amp. Copper Bus Bar (3 Phase + Neutral), 5 No. 32 Amp. TPN MCB, 12 No. 40 Amp. DP MCB, 40 No. Link type Terminal Bock, Cable Glands etc. with Internal Wiring and then Installation of each L.T. A.C. Cubical on 1 meter long M.S. Angle Frame Structure after due Fabrication with the help of Scrap M.S. Angles to be Provided by the Department Free of Cost and Grouting of Legs of the M.S. Angle Frame Structure in the Ground with C.C. Mixture and Painting of the M.S. Angle Frame Structure with Synthetic Enamel Paint. (1 Job per L.T. A.C. Cubical)
1
-
-
Earthing of L.T. A.C. Supply Cubical with Providing & Fixing of 600 × 800 × 8 mm size G.I. Plate with its Top At Least 3 Meter below the Ground Level with 20 mm dia. G.I. Pipe & Funnel for Watering, 1 No. 8 SWG G.I. Wire Earthing Lead etc. with Alternate Layer of Charcoal / Coke and Salt at Least 150 mm Thick Around it.
1
-
-
Providing & Fixing of 150 Watt L.E.D. Street Light Luminaries Fittings of Philips / Compton Greaves / Havells make with IP 65 rating in Single Piece Die Cast Aluminium Alloy Housing with Pot Optics Reflector & Toughened Clear Glass Cover with Frame for Lamp Compartment inlcuding Cable Terminations.
15
-
-
Providing & Fixing of Junction Box of size 280 × 225 × 150 mm duly made of 16 SWG Sheet and Painted with Smoke Grey Colour Synthetic Enamel Paint and Fitted with 1 No. 6 Amp. SP MCB on Anodized M.S. Channel, 1 No. Bakelite Fuse Fitting with 6 Amp. NS 6 type HRC Fuse, 1 No. Copper Neutral Link, Bakelite Terminal Block of 4 Terminals, Cable Glands suitable for 2C × 2.5 mm2 / 4C × 2.5 mm2 size Incoming / Outgoing Control Cables etc., then Installation of Junction Box on M.S. Round Pole at designated Height with the help of suitable M.S. Clamps alongwith Earthing of the Junction Box with 12 SWG G.I. Wire including Cable Terminations with Satisfactory Testing & Commissioning
10
-
-
Providing & Fixing of G.I. S.L. Pole Bracket duly made of 40 mm dia. 1.2 Meter Long ‘B’ Class Pipe and Bent at One End by Quarter Circle in 1.0 Meter at an Angle of 300 for Fixing of 150 Watt LED Street Light Luminaries Fittings on M.S. Round Pole with help of M.S. Clamps
10
-
-
Laying of 3.5x70/50 sq.mm LT Power Cable, 50cm below the ground level after Excavation of trench, Laying the 1st class brick lining, filling of river sand along & over the cable, then back filling & levelling the trench after Laying of Cable. The work also includes Termination of cable on both sides with Crimping of Lugs.
200
-
-
Laying of 2C x 2.5sq.mm size Control cables from LT A.C.D.B. Cubical to various junction Boxes for Switchyard Lighting through through Excavated Trench of size 300x600 mm, Covering the cables with River Sand & Brick Lining along & Over the Cable, then Back filling & levelling of the trench after Laying of Cables.
200
-
-
Laying of above Control Cables from L.T. Lighting Junction Box to LED Street Light Fittings by clamping with suitable M.S. Strip Clamp with proper Dressing etc.
100
-
-
Providing & Fixing of Cable Marker duly made of Cast Iron.
10
-
-
Earthing by Cutting, Straightening & Laying 500 mm below Inside Ground & above Ground of Following sizes M.S. Round Bar, Provided by the Department for Diagonal / Double Earthing of the Main & Aux. Structures, Equipments and Cable Trenches including Welding with Main Earth Mat and with the Object to be Earthed including Excavation of Trenches & its Back Filling etc. as per Details below :
-
-
-
40mm dia MS Round Bar for Earth-Mat
350
-
-
Earthing Electrode of 40mm Dia of 03 meter length
65
-
-
Earthing by Cutting, Straightening & Laying 500 mm below Inside Ground & above Ground of Following sizes for Diagonal / Double Earthing of the Main & Aux. Structures, Equipments and Cable Trenches including Welding with Main Earth Mat and with the Object to be Earthed including Excavation of Trenches & its Back Filling etc. as per Details below :
-
-
-
Earthing of Main Structure with 50 × 6 mm size M.S. Flat
80
-
-
Aux. Structures and Equipments (CBs, Isolators, CTs, PTs, C&R Panel, DPP, Junction Boxes etc. with 50 × 6 mm size M.S. Flat
300
-
-
Painting of M.S flat size 50x6 sq. Mm. After using red oxide primer and painting with green color ISI marked paint two coats on both sides.
380
-
-
Supply of various Items required for erection of structures and equipments and stringing work along with earthing of the equipment and structures for extension of 33KV Main Bus and Capacitor Bank Bus along for Shifting of existing and New Capacitor Bank
-
-
-
Single Tension Fittings Suitable for ACSR Moose
12
-
-
Single Tension Fittings Suitable for ACSR Panther
12
-
-
PG Clamps suitable for Moose / Moose
12
-
-
PG Clamps suitable for Moose / Panther
12
-
-
PG Clamps suitable for Panther / Panther
42
-
-
Bus Post Clamp suitable for Moose
6
-
-