Uttar Pradesh Power Transmission Corporation Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date29 Dec 2023
Closing Date15 Jan 2024
Tender Amount₹ 72,20,849 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth filling under floors and/or corporation area including cost of earth obtained with in 8 km distance outside corporation area including all taxes (if any) and its carriage including watering, ramming in 20 cm layers and dressing of earth etc. all complete. (CSI No. 4.10)

1700

741200

436

... More
Levelling and dressing and making proper slopes including cutting and filling of earth upto a depth 100mm if so required including all labour T&P etc. required for proper completion of the work . (CSI No. 4.11)

1200

4800

4

... More
Concrete with 4cm gauge stone ballast, coarse sand & cement in proportion of 12:6:1 in foundations &under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No. 5.02)

28

149884

5353

... More
Concreting of 40 mm thick RCC trench covers in mild steel frame work with RCC 1:1.5:3 in Cement, coarse sand and 2cm gauge graded hard stone ballast with 3mm thick floating coat of neat cement finish on top of cover complete with all labour, materials and placing the same in proper position at required location of cable trench within the substation area. (CSI No. 5.18)

65

22750

350

... More
Cement concrete with 2cm gauge approved hard stone ballast, coarse sand and cement in proportion of 3:1.5:1 including supply of all materials, labour,side shuttering if required and T&P etc. required for proper completion of work (CSI No. 5.21)

7

52164

7452

... More
RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast like granit, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3 in lintels or bends and sun shade of doors and windows, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P. (CSI No. 5.23)

6

51624

8604

... More
RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast like granite, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3 in slab, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P (CSI No. 5.24)

4.4

43551

9898

... More
RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast like granite, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3 in lighter beams i.e. having span upto 6m, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P . (CSI No. 5.25)

1

10707

10707

... More
RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast like granite quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3 in raft foundation and footings , excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P. (CSI No. 5.27)

17

139519

8207

... More
RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast like granite quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3 in RCC pile caping, gantry walls/column foundations and RCC pedestals, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P. (CSI No. 5.28)

158

1336838

8461

... More
RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast like granite, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3 in RCC T beam-slab and column, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P . (CSI No. 5.29)

3.5

38041

10869

... More
First class brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour & T&P etc. required for proper completion of work. (CSI No. 6.01)

18

98658

5481

... More
First class brick work in 1:4 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour & T&P etc. required for proper completion of work (CSI No. 6.03)

21

119238

5678

... More
Add to item 6.01 above for extra labour in super structure including necessary cutting and moulding of bricks as required and also including honeycomb brick work, thickness of wall not to be less than 1.5 brick. (CSI No. 6.07)

12

4536

378

... More
As in item 6.07 above but for walls of one brick thickness. Add for extra labour to the rates of item No.6.07. (CSI No. 6.08)

12

3852

321

... More
S/Fixing of double action floor springs including cutting in floors / RCC slabs and grouting the same with C.C. & finishing the surface properly as and where required under aluminium doors as per direction of Engineer-in-charge. including cost of all other material, labour, tools & plants etc. complete. (CSI No. 8.52)

1

10016

10016

... More
P/F fully Anodized aluminium fixed glazing with HINDALCO or equivalent extruded standard sections14gauge (2.41mm thick) of various cross sections and joints mitred and jointed as shown in drawing including providing & fixing 5.5 mm thick toughened glass with Neoprene beading & aluminium glazing clips all around. The minimum thickness of anodizing on all aluminium sections should be 20 microns with a (+) 2 microns tolerance for openable window portion as shown in drawings, including cost of Aluminium hinges and all other fittings like concealed tower bolts handles etc of approved quality and including cost of all other material, labour, tools & plants etc. complete. (CSI No. 8.68)

2.4

11258

4691

... More
Same as in item No. 8.68 but for openable gate/door portion as shown in drawings including cost of hinges and Aluminium fittings like tower bolts, handles, stoppers, push plates, brass body with brass component 6 levers cocealed lock etc of heavy & approved quality and including cost of all other material, labour, tools & plants etc. complete. (CSI No. 8.69)

2.25

9074

4033

... More
Mild Steel or Iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof work gates etc. wrought to required form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost of all materials supplied by contractor. (CSI No. 9.01)

2

198128

99064

... More
TMT/Tor steel in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage, bend, hooks and authorized overlapping shall be measured. (Steel shall be arranged by the contractor) (CSI No. 9.03)

8

704544

88068

... More
Supply of 28 mm. dia M.S. Anchor bolts (conforming to IS 266) 900 mm. long with base plate (75x75x6mm) welded with anchor bolts including its threading upto a length of 10cm. and also supply of a pair of galvanized standard nuts with threading including supply of 5 mm thick washer and cost of labour, material & T&P for proper completion of work(CSI No. 9.12)

224

141120

630

... More
Fixing and grouting 28 mm and above dia bolts in proper alignment level and setout with help of a template complete including supply of all labour & T&P etc. required for proper completion of the work.(labour rates only) . (CSI No. 9.13)

224

14560

65

... More
Supply of 25 mm dia.M.S. Anchor bolts (conforming to IS-226) 500 mm long with base plate(50x50x6 mm)welded with anchor bolts,including its threading upto a length of 10cm. and galvanizing upto 15cm from top, also supply of a pair of galvanized standard nuts with threading including supply of 5mm thick washer and cost of labour material and T&P etc. required for proper completion of the work. (CSI No. 9.14)

126

51156

406

... More
Fixing and grouting 25 mm and below dia M.S. Anchor bolt in proper alignment level and setout with the help of a template including supply of all labour T&P etc. reqd. for proper completion of the work. (labour rates only) . (CSI No. 9.15)

136

6936

51

... More
Providing M.S. Frames work, rack etc for R.C.C. Trench covers and edging with M.S. angles and M.S reinforcement including cutting, bending and welding as per approved drawing. The rate is including cost of all labour, materials etc. as required for proper completion of the work. (CSI No. 9.20)

4.5

433809

96402

... More
S/F 50x50mm, 8 gauge G.I. chain link fencing 1.8 M high including fixing to vertical posts, horizontal runners with 10mm dia. 40mm long bolts, nuts and washers complete with all material, labour and T&P etc. required for proper completion of work. Chain link of 8 gauge shall be galvanized by hot dipped method as per relevant IS Code. (Excluding cost of vertical posts and horizontal runners) (CSI No. 9.23)

150

121050

807

... More
As per item No 9.23 above but excluding the cost of G.I.chain link ( Fixing charges only). (CSI No. 9.24)

100

32300

323

... More
Grouting of vertical or inclined post of pale/chain/security fencing in true level, alignment and in plumb or inclination as required, including cost of all labour, materials and T&P required for proper completion of work. ( Post and concrete for grouting shall be measured separately) (CSI No. 9.28)

36

2016

56

... More
Fixing and grouting of trench edging in proper level and alignment including cost of all labour, and T&P etc. required for proper completion of the work but excluding cost of C.C. (labour rates only) . (CSI No. 9.30)

550

7150

13

... More
Fixing of template in position level and alignment for grouting of Anchor bolt in main gantry (labour rate only). (CSI No. 9.31)

7

1897

271

... More
Fixing of template in position level and alignment for grouting of Anchor bolt in auxiliary structure (labour rate only). (CSI No. 9.32)

17

2856

168

... More
Fixing of cable trench racks in proper position and alignment including cost of all labour, material and T&Petc. required for proper completion of the work (Labour rate only) . (CSI No. 9.33)

540

5940

11

... More
12 mm thick plaster with cement mortar consisting of one part of cement & four part of coarse sand (1:4), minimum thickness not to be less then 10 mm including supply of all material, labour and T&P etc for proper completion of work. (CSI No. 11.07)

400

79200

198

... More
S/mixing approved water proofing compound (CICO,DR FIXIT etc) in cement mortar in plaster or concrete work in the proportion as recommended by the manufacturer. (CSI No. 11.15)

10

470

47

... More
Champering the edge of concrete in auxiliary structure, of size 25 mm wide in triangular section including all materials, labour & T&P etc complete. (CSI No.11.18)

460

4140

9

... More
3 mm thick floating coat of neat cement finish including supply of all materials,labour and T&P etc. required for proper completion of the work.( cement consumption 0.044 bag/Sq.m.) (CSI No. 11.20)

400

8400

21

... More
2.5 cm thick 1:2:4 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and including 7.5 cm thick base concrete consisting of cement, coarse sand and 4cm gauge I class brick ballast in the proportion of 1:6:12 and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work but without base CC (CSI No. 12.02)

50

13400

268

... More
First class brick on floor-laid flat in cement mortar consisting of one part of cement and six parts of coarse sand and pointed with cement mortar 1:2 over and including all materials, labour, T&P etc.required for proper completion of work. (CSI No. 12.16)

100

52900

529

... More
Providing and laying floor of 8 mm thick vitrified tiles in flooring or skirting of approved brand (Bell, Johnson or equi. make) size of 600x600 mm of approved shade, colour and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cement mixed with pigment to match the shade of tile including cost of all material, labour and T&P required for proper completion of the work. (CSI No. 12.18)

16

21552

1347

... More
Painting or varnishing new iron work in small areas or new wood work with one coat of ready mixed priming paint and one coat of approved superior quality ready mix paint "Luxol" or equivalent brand or varnish including supply of all materials, labour and T&P etc. required for proper completion of the work. Paint to be used should conform to the I.S. 103-1950. (CSI No. 13.01)

145

11165

77

... More
As in item 13.01 above but for every coat after first coat. (CSI No. 13.02)

145

5220

36

... More
Applying Birla or equivalent putty on new interior or exterior surface over one coat of water based cement primer of ICI or equivalent brand for smoothening and levelling of the surface as per requirement and direction of Engineer I/C including cost of all material, labour, T & P etc required for proper completion of work. (CSI No. 13.20)

190

16910

89

... More
Painting one coat with APEX or equivalent brand weather coat paint on new wall surfaces (well prepared with Birla putty and one coat of primer ICI or equivalent which shall be paid separately) including through washing with water including cost of all materials, labour, T&P required for proper completion of work. (CSI No. 13.22)

70

6860

98

... More
Same as in item no 13.22 above but for every coat of additional APEX or equivalent brand weather coat paint . (CSI No. 13.23)

70

3080

44

... More
Painting one coat with Acrylic emulsion paint of Berger/ Asian/ ICI or equivalent paint (Paint and water in the ratio 1:1 by volume) over prepared and primed surface of cement concrete, cement plaster and bricks including all labour, material and T&P etc required for proper completion of the work, (preparation of base with Birla putty etc. and a coating of primer shall be paid extra) . (CSI No. 13.25)

50

4900

98

... More
Same as above in item no. 13.25 but for every coat after first coat of Acrylic emulsion paint of Berger/ Asian/ ICI or equivalent paint. (CSI No. 13.26)

50

2200

44

... More
Dismantling brick work or stone work in lime or cement mortar and including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metres. (CSI No. 15.01)

4

2332

583

... More
Dismantling reinforced cement concrete or reinforced brick work, including stacking of dismantled materials as directed by the Engineer-Incharge within a distance of 60 metres. (CSI No. 15.03)

4

5172

1293

... More
Dismantling of existing pale / security / chain link fencing including post and stacking properly as per direction of the Engineer - in - charge. Including all labour and T&P etc. required for proper completion of the work. (CSI No. 15.13)

60

8040

134

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber & consolidating with road roller including making good the undulations etc.& re-rolling the sub grade & disposal of surplus earth with lead upto 50 metres. (CSI No. 18.01)

114

84132

738

... More
Consolidation of stone ballast of 25 mm to 50 mm size laid 150 mm thick and consolidation upto 115 mm thick with road roller (10 MT) including repairing of patches in existing road surface with stone picking up old surface spreading stone ballast blinding with muddy earth to retain water including cost of earth cartage upto site spreading and ramming etc and also including cartage of metal upto work site carriage of water of required quantity and also including opening and sorting of stacks etc complete as per detailed U.P. PWD specification 204 and also including hiring charges of road roller and cost of fuel and driver etc including cost of all labour, materials, T&P etc. including cost of stone ballast complete. (CSI No. 18.04)

54

36774

681

... More
As in item 18.04 above but for 4cm. to 9cm. size stone ballast. (CSI No. 18.05)

54

40932

758

... More
Laying cement concrete road slab consisting of 1 part cement 1.5 part approved coarse sand and 3 part approved 20mm down graded stone aggregate over prepared sub grade after its rectification and bringing it to proper camber and shape,finishing with TRIMIX machine ,concrete hardner and making good to the satisfaction of E/I inclduing cost of all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 18.13)

62

541942

8741

... More
Providing and fixing 12mm thick particle board of commercial quality 125 mm deep for making partitions of C.C. road slab as per direction of E/I. including cost of all material, labour and T&P required for proper completion of work. (CSI No. 18.15)

104

18616

179

... More
(2.0) BALLASTS, SHINGLES & ROAD METAL 2 (f) Road metal 25-50/40-63/40-90mm. SI 2.f+10%CP

105

177754

1692.9

... More
Boring holes 3.5 M deep below cut off Level in all types of strata including loose sandy strata under water requiring use of modified auger and cutting tools with gravity valves and removable casing pipe, if required, for proper completion of work with cost of all labour, material, T&P required. (CSI No. 21.01) (b) 300 mm Dia piles .

60

81360

1356

... More
(c) 400 mm Dia piles.

46

78430

1705

... More
Cutting the bore hole for providing under ream of 2.5 times the dia. of pile upto 3.50 metre below the cut off leveling tools including cleaning the bore hole and including cost of all materials, labour and T&P etc. as may be required for proper completion of work. (CSI No. 21.02) (b) For 300 mm dia pile.

60

46980

783

... More
(c) For 400 mm dia pile.

46

43562

947

... More
Extra for every additional depth of boring work as described in item No.21.01 above but beyond 3.50 Metre below the cut off level. (CSI No. 21.03) (c) For 400 mm dia piles.

28

27580

985

... More
As in item N0. 21.02 above but for under reaming beyond 3.50 Metre below the cut off level. (CSI No. 21.04) (c) For 400 mm dia piles.

28

43848

1566

... More
Supply and fabrication of M.S. (tor) reinforcement cages for piles including cutting, bending, welding as per design and placing of the cage in the pile bore including cost of all material, labour,and T&P etc. as may be required for proper completion of the work including all incidental wastage. (CSI No. 21.06)

3.4

303922

89389

... More
R.C.C. work with cement, approved coarse sand 2cm gauge approved stone ballast in 1:1.5:3 proportion for concreting in all type of piles including labour & material for proper completion of the work. Measurement of work be done according to design diameter and depth of pile upto cut off level. Under reamed concrete shall be measured as per IS 2911 Part II (CSI No. 21.08)

55

538285

9787

... More
Cutting & chipping the piles top above the cut off level including bending & straightening the pile reinforcement as directed including cost of al materials, labour & T&P etc as may be required for completion of the work. (CSI No. 21.11) (b) For 300 mm dia pile.

60

25560

426

... More
(c) For 400 mm dia pile.

46

24978

543

... More
Providing and fixing false ceiling at all heights with integral densifiedr Armstrong false ceiling tiles of Size 595x595 x12 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as perBS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 SUB HEAD : 26- NEW TECHNOLOGIES AND MATERIALS 1632 mm reveal profile white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. 26.23.1 With 12 mm thick Armstrong Miniral Fobre Sound Absorbing Sheet (CSI No. 28.30)

21

29904

1424

... More
Wiring point for light with 1.5 sq mm FRLSH PVC insulated multistrand single copper conductor cable in heavey gauage rigid pvc conduit pipe 14 SWG earth wire drwan inside the conduit GP Box,paino type switch and cieling rose angle battern holder on 3 mm thick phenolic laminated backelite Sheet etc complete in all respect as directed including matching colour wash (131 C PWD 2018)

4

2572

643

... More
wiring point for Fan/Fresh air fan (light duty exhaust fan) 1.5 sq. mm FRLSH PVC conduit insulated multistrand copper conductor cable as earth wire drawn inside the conduit PVC conduit pipe concealed in the wall 14 SWG coper earth continuty wire and approved qualit piano type switch & ceiling rose as per approved sample on 3mm thick phenolic laminated backelite sheet etc. of maching shade with colour complete in all respects including matching colour wash (pwd 133 C)

1

708

708

... More
wiring point for Plug 1.5 sq. mm FRLSH PVC conduit insulated multistrand copper conductor cable as earth wire drawn inside the conduit PVC conduit pipe concealed in the wall 14 SWG coper earth continuty wire and approved qualit piano type switch & socket etc complete in all respects including matching colour wash (pwd 134 C)

3

1005

335

... More
S/W of submain with two number 4sq. mm FR PVC insulated 1100 V grade multistrand copper concealed cable in 20 mm dia heavy duty (2mm thick) PVC conduit concealed in wall complete with one number 2.5 sq.mm FR PVC inslated multistrand copper conductor cable as earth continuity wire etc. complete in all respects. (pwd 216C)

15

2370

158

... More
S/W of submain with two number 6sq. mm FR PVC insulated 1100 V grade multistrand copper concealed cable in 25 mm dia heavy duty (2mm thick) PVC conduit concealed in wall complete with one number 4 sq.mm FR PVC inslated multistrand copper conductor cable as earth continuity wire etc. complete in all respects. (pwd 217C)

12

2580

215

... More
S/F of 6 Amp to32 Amp. SPMCB(10KA) C Curve (CAT A) (PWD 1002)

2

520

260

... More
S & F of 63 Amp. SP Isolator (CAT B) (PWD 1004B)

1

280

280

... More
S/F of power plug with 15A/250V flush type switch and 5 pin 15A/250V flush type universal socket in suitable MS Box of 175 mmx100mmx50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. (PWD 1139)

3

1020

340

... More
S/F hexagonal/round G.P. fan box of approved make made of 1mm thick ISI marked GP sheet spot belded 4 to 8 hole of 25.4mm for pipe entry of the box holes should be semi-shuttered type with 0.5mm GP sheet made upper and lower cover duly screwed fitted with 300mm round zinc coated MS bar X 12mm and brand name should be embossed. Fixing with wiring conduit laid in the RCC roof before concreting along with supply of all material, labour, T&P etc. (PWD1149)

2

300

150



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.