Uttar Pradesh Power Transmission Corporation Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Feb 2025
Closing Date24 Feb 2025
Tender Amount₹ 48,49,000
Costs
EMD
₹ 48,500Document Cost
₹ 1,770Tender Fee
Refer Documents
Summary
Work Of Replacement Of Existing 02 No. 40 Mva 132 / 33 Kv transformers By New 63 Mva 132 / 33 Kv Transformers And
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_UPTCL_1001634_1Tender No
E-Tender-49/ETC-I/2024-25Tender Authority
Uttar Pradesh Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://https://upenergy.in/upptcl
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Shifting of Main Tank of 132 / 33 KV 40 MVA Transformer-II to storage place from the Plinth up to 20 Meter distance including turning of Tank if required.
2
-
-
... More
Additional Shifting of Transformer Tank upto 150 Meter distance for each transformer (Total 300 Mtr)(1 Job for every 5 Meter)
60
-
-
... More
Shifting of Main Tank of 132 / 33 KV 63 MVA Transformer to Plinth from place of storage up to 20 Meter distance including turning of Tank if required.
2
-
-
... More
Additional Shifting of Transformer Tank upto 120 Meter distance for each transformer (Total 240 Mtr)(1 Job for every 5 Meter)
48
-
-
... More
Performing the following precommissioning CT test on all turret CT before erection of 63 MVA TF:
a. Ration Test
b. IR test c. Continuity Test
d. Winding resistance
e. Polarity test
f. IR of CFT
6 Job for one TF, Total 12 Jobs
12
-
-
... More
Performing pre-commissioning Tan delta test on HV & LV bushings of Transformer before erection of 63 MVA TFs using standard testing kits with valid caliberation certificate. Note: Any other test required by TF manufacturer will be under scope of contractor.
2
-
-
... More
Performing pressure test by using dry air on all radiators @ 0.3KGg/cm2 with holding time 30 Min for checking leakage before erection of 63 MVA TFs.
Performing leakage test on aircell using dry air with pressure 0.07kg/cm2 & pressure test on conservator tank using dry air with pressure 0.5kg/cm2 (Air cell should not be in pressurised condition) for checking leakage before erection of 63 MVA TFs. If pressure drops, leakage point to be identified and attended.
Note: Dry air plant to be arranged by contractor .
2
-
-
... More
Complete Erection of 132 / 33 KV 63 MVA Transformer including Radiators, Conservator Tank, Bushings, Connecting Pipe Lines, Cooling Fans, Marshaling Box, OTI, WTI, Capilliary Pipes etc.
2
-
-
... More
Top up with fresh Transformer Oil from Transformer Oil Drums in main tank,bushings&conservator of transformer upto required level
2
-
-
... More
Centrifuging / Dehydration of the complete Transformer Oil of both Transformers (24200 Ltr for each Transformer) by Ultra High Vacuum Oil Filtration Plant after connecting the Centrifuging Pipes with Oil Tanker to Oil Filtration Plant including taking the BDV Values of Oil and megger values of the Transformer periodically till the required value is achieved, with all cost of Centrifuging Machine, CFM Operator, Lubricants etc.
48400
-
-
... More
Performing complete testing of Transformer with standard testing equipment with valid caliberation certificate. Following tests are to be completed:
a. Tan delta & capacitance measurement at standard & variable frequencies of 03 No. HV & 03 No. LV bushing (using omicron/ megger kit) after erection.
b. LV testing of Transformer including magnetising current test, magnetic balance test, WRM, vector group, insulation resistance, core insulation, voltage ratio test, SC test, OC test. Test report to be compiled & submitted in required formats as per satisfaction of competent authority. Note: Any other tests required by TF manufacturer will be in contractor scope.
2
-
-
... More
Sampling & testing of T/F oil at CPRI or any other NABL testing lab including cost of transportation of sample in standard sampling bottles (adequate no. of bottles to be arranged by contractor). Samples to be taken at following intervals:
1. before filling in T/F main tank & OLTC-02 samples.
2. Before charging, at top and bottom of main tank & OLTC- 05 samples.
Following tests to be performed:
i. BDV
ii. PPM
iii. Tan delta
iv. Resistivity
v. Interfacial tension.
vi. Particle count
vii. DGA
(one job for each sample.)
Note: Any other tests required by T/F manufacturer shall be under scope of contractor.
6
-
-
... More
Making of 02 No. Additional Delta for Neutral Earthing by due fabrication of 3 No. 3.5 Meter long Electrodes of 36 / 40 mm dia. M.S. Round Bar, its piercing under the ground at equal distance of 1 Meter at 700 mm depth by digging of earth and connecting all the 3 No. Electrodes with 75 mm x 10 mm size M.S. Flat & connecting with existing Earthmat and taking out Riser by due cutting, bending, welding etc. as per Technical Specifications. 1 Job for each Transformer.
2
-
-
... More
Earthing of Main Tank, Marshaling Box, Drive Mechanism, Transformer Neutral etc. of 63 MVA Transformer with the help of 50 x 6 mm / 75 x 10 mm size M.S. Flat, its jointing with already laid Earthmat / Deltas including Additional Delta at 2 places and necessary modification in existing support for Earthing of Neutral Bushing support for its Earthing work and then Painting of Earthing Strips as per technical specifications / standard practice. 1 Job for each Transformer.
2
-
-
... More
Erection of 63 MVA Transformer RTCC Panel including Shifting from storage place to C&R Room as per direction of site Engineer.
2
-
-
... More
Jumpering of HV & LV Bushings of 63 MVA Transformers through 132 K.V. and 33 K.V. LAs with the help of existing / newly prepared ACSR Twin Moose Conductor respectively with associated Terminal Connectors and P.G. Clamps etc. to connect with 132 K.V. & 33 K.V. Bus Bars / CTs. 1 Job for each Transformer.
2
-
-
... More
Connection of the Cables as per new Cable schedule of 63 MVA Transformer & its RTCC Panel at both ends and Control & Relay Panel, Cooling Fans, Marshaling Box etc. using existing Cables including Laying of additional Control Cables (if required), making necessary holes in the Glands Plates or Box wherever required, Supply & Fixing of Cable Glands of appropriate size, providing of Ferrules as per site requirement and Termination and connection of all existing / new Control Cables at RTCC & Transformer End and C & R end as per standard practice & all other associated works as per Technical Specification. 1 Job for each Transformer.
2
-
-
... More
Proper Packing of HV / LV & Neutral Bushings of dismantled 40 MVA Transformer including proper wrapping with Polythene Sheet in Wooden Crates of new Bushings of 63 MVA Transformer. 1 Job for each Transformer.
2
-
-
... More
Dismantling of 33 K.V. 800 / 1 Amp. CTs by due Opening of Jumpers, Earthing, Cable Connections, Nut & Bolts etc. and Shifting upto Store / designated place at the Sub Station as per direction of site Engineer. 3 Job for each Transformer.
6
-
-
... More
Safe Carriage of 33 KV 33 KV 2000/1250/1 amp. 3 Nos CTs from Transmission Substation in Lucknow (as per availability) to 132 KV Substation Indira Nagar including Loading and Unloading . 1 Job for each Transformer.
2
-
-
... More
Erection of 33 K.V. 2000 - 1250 / 1 Amp. CTs as per instruction manual and Technical Specifications including shifting of CTs from Store to Erection site including necessary connection of Cable & Earthing and Jumpering on both sides. 3 Job for each Transformer. 3 Job for each Transformer.
6
-
-
... More
Dismantling of 120 KV LA alongwith ALP structure and proper stacking after opening of jumpers and disconnection of earthing for both Transformers ( 1 Job for each set of LA and ALP structure)
6
-
-
... More
Erection of 120 KV LA including erection of ALP structure and connection of earthing with existing MS flat at designated places and jumpering with jack bus as per technical specifications for both Transformers ( 1 Job for each set of LA and ALP structure)
6
-
-
... More
Electrical Safety processing fees needed for providing all relvant safety clearance documents from electrical safety department for energisation of the above commissioned 2x63 MVA Transformers and its accessories (Note: The amount payable is actual rate of challan or quoted rate, whichever is lower)
-
-
-
... More
63 MVA Power Transformer
2
-
-
... More
All LA associated with newly commissioned 63 MVA Transformers
12
-
-
... More
HT inspection fees
2
-
-
... More
Fabrication of protective net for radiators of 132/33 KV Transformers, control room glass window, JE room glass window and associated works:
-
-
-
... More
Providing, fabrication and fixing of protection net on top and in front of radiator for protection of radiator of Trasformer, made of MS channel, angle, mesh and cross section type net. Size of protection net , 2900mm x 2400mm and size of top protection net 2900mm x 1200mm including all cost of men and material-
-
-
-
... More
New 132/33 KV 63 MVA Transformer -I
10.44
-
-
... More
New 132/33 KV 63 MVA Transformer -II
10.44
-
-
... More
Providing, fabrication and grouting of MS Channel size 4500mm long at 2 places in front of radiator by concreting for support of protection net by welding or nut & bolt as required , including all cost of men and material:
-
-
-
... More
New 132/33 KV 63 MVA Transformer -I
9
-
-
... More
New 132/33 KV 63 MVA Transformer -II
9
-
-
... More
Fabrication and fixing of 03 no. P.I. on the top of front protection for extra support of LV side conductor including all cost of men & material:
-
-
-
... More
New 132/33 KV 63 MVA Transformer -I
1
-
-
... More
New 132/33 KV 63 MVA Transformer -II
1
-
-
... More
Following works including Providing of materials are to be carried out at 132 KV S/S Indira Nagar Lucknow for Proper Lighting arrangement along the two number 63 MVA Transformer bays and other crucial places in switchyard with all cost of men, materials ,T&P etc . Except Cables Which shall be Provided by the Department as per direction of Supervising Engineer .
-
-
-
... More
Providing of Lighting Junction Box of size of 280 mm x 150 mm made of 16 SWG M.S. B.P. Sheet & Painted with smoke Grey colour synthetic enamel Paint, duly fitted with 1 No 6 Amp. S.P. M.C.B. on Anodised M.S. Channel ,1 No Bakelite Fuse Fitting with 6 Amp. ,Capacity NS 6 type HRC Fuse,01 No . Copper Neutral Link ,Bakelite terminal strip of 4 Nos. terminals,Cable Glands suitable for 2C /4C x 2.5 Sq. mm size incoming /outgoing Control cable etc.& fixing on the GI Structure at designated height with the help of suitable duly fabricated M.S. Bracket Clamps and Due earthung of the Junction Box including Cable Terminations.
15
-
-
... More
Providing & Fixing of G.I. S.L. Pole Bracket duly made of 40 mm dia B class 1.20 Meter long M.S. Pipe of (ID 35 mm& OD 40 mm) and bent at one end by quarter circle in 1.0 mtr. At an angle of 30 deg for fixing of 150 watt LED street Light Luminaries Fittings with the help of MS Bracket Clamps of suitable size for fixing on G.I. column structure at designated place.
15
-
-
... More
Provinding & Fixing of 150 Watt LED Street Light Luminaries Fittings of PHILIPS/ CROMPTON / HAVELLS/ BAJAJ Make in Single Piece die cast aliminium Alloy Housing with Pot Optics Reflector & Toughed Clear Glass Cover with Frame for Lamp Compartment including Cable Termination .
18
-
-
... More
Cable laying & Termination-
-
-
-
... More
Laying of following size PVC insulated Copper Control cable from LT ACDB Cubical to Various Junction Boxes below ground level in PVC Conduit pipe (Provided by the contractor ) after due excavation ,back filling etc. including all labour ,PVC Pipe etc. required for proper completion of the work .
-
-
-
... More
2 C x 2.5 Sq mm
850
-
-
... More
Laying of Control cables between LT Lightinig Junction box & LED Street Light Fittings along GI Structure including necessary clamping with suitable M.S. street clamp with Proper Dressing .
360
-
-
... More
Providing & fixing of Post Lamp Glow Light of latest design complete with white color defuser suitable for installation at main entrance/garden/lawn lighting.
10
-
-
... More
Supply related to construction of 01 No. additional 33 KV TBC Bay, 01 No. 33 KV additional section isolator and other associated works:
-
-
-
... More
Supply of Post insulator Clamp suitable for Twin Panther Conductor
6
-
-
... More
PG clamp made of aluminum alloy LM-6 suitable for Moose-to-Panther conductor as per specification. HDG nut & both and washer as per technical specification.
6
-
-
... More
PG clamp made of aluminum alloy LM-6 suitable for Panther-to-Panther conductor as per specification. HDG nut & both and washer as per technical specification.
15
-
-
... More
Supply of HDG nut & bolt and washer size 10x50 mm as per technical specification.
0.1
-
-
... More
Supply of spacer 100mm dia for Panther conductor
24
-
-
... More
Works related to construction of 01 No. additional 33 KV TBC Bay, 01 No. 33 KV additional section isolator and other associated works:
-
-
-
... More
Safe carriage of auxiliary structures from E.F.U Naini Prayagraj to 132 KV substation Indra Nagar Lucknow including loading on carriage vehicle unloading sorting and stacking of different structures as per BOQ/ Material Schedule at receiving site.
1.5
-
-
... More
Erection of following structures/equipment for construction of 33 KV TBC bay at substation as per instruction manual of various equipment and technical specification including shifting of structures / equipment from store to erection site including all other associated work for completion of erection work satisfactorily.
-
-
-
... More
Aux. Structure
1.5
-
-
... More
33 KV CB
1
-
-
... More
33 KV CT
3
-
-
... More
33 KV Bus Isolator without earth blade
3
-
-
... More
33 KV CT Junction Box
1
-
-
... More
33KV Post Insulator
3
-
-
... More
Cutting Straightening laying 700 mm below inside ground and above ground of 50 mm X 6 mm size and 25 mm X 5 mm M.S Flats to be provided by department as per requirement at substation for earthing for newly erected Main and Aux. Structures, Equipment, Cable , Trenches including welding with main Earthmat and with the object to be earthed excavation of Trenches, its back filling, Painting of Earthmat above ground level in Bus Green colour including all other associated works to be complete to the earthing work satisfactorily as per technical specification.
-
-
-
... More
Earthing of Aux. Structures and Equipment with 50 mm X 6 mm size M.S Flats
200
-
-
... More
Earthing of new cable, Trech Rack/Peak Mast with 25 mm X 6 mm size M.S Flats
120
-
-
... More
Jumpering of Equipment of 33 KV TBC Bay with the help of ACSR Panther Conductor including Bus Bar (Main & Transfer) conductors to equipment with suitable clamp to be provided by the department
1
-
-
... More
Laying of following sizes of Control Cables in the cable Trenches from Control & Relay Panels in control Room to various Equipment, Junction Boxes etc. in Switchyard as per cable schedule, its saddling with 25 mm X 3 mm size including Carriage of Cable Drums from Stores to Work Site and shifting back to Store the balance cable included all other associated works to complete the job satisfactorily as per technical specifications.
-
-
-
... More
Laying of 2 mm X 2.5 mm2 size control cable
0.5
-
-
... More
Laying of 4 mm X 2.5 mm2 size control cable
1
-
-
... More
Laying of 6 mm X 2.5 mm2 size control cable
0.5
-
-
... More
Inter – Connection and termination of above laid Control Cables between new 33 KV Tripple Feeder C&R Pannel and Erected Equipment i.e. CB, CT, CT Junction Box, PT, PT Junction box including making necessary holes in gland platers of boxes wherever required along with supply and fixing of Cable Glands of appropriate size and providing Ferules of each core of the Cable and its termination with crimping type Copper Lugs along with preparation of inter-connection Drawing and commissioning of the Pannel / feeder coordination with T&C wing including proving of 02 sets of hard copies of as executed inter-connection drawing including all other associated work to complete the job satisfactorily as per technical specification.
1
-
-
... More
Spray/ brush Painting of following equipments/items painting includes one coat of red oxide and two coats of Green/Red colour good quality Asian/Burger/Nerolac make paint after through rubbing and cleaning of old scale of painted surface to remove rust,dust etc.
-
-
-
... More
Earthing strip 75 x 10 mm in green Colour
2100
-
-
... More
Earthing strip 50 x 06 mm in green Colour
650
-
-
... More
Switchyard lighting JB in smoke grey color
3
-
-
... More
132KV Isolator operating box in smoke grey color
22
-
-
... More
132KV CT/CVT in smoke grey color
13
-
-
... More
33 KV Isolator Operating Box in smoke grey colour.
15
-
-
... More
33 KV CT & PT Junction Box in smoke grey colour.
28
-
-
... More
Work and supply related to work of installation of CCTV camera at crucial places of substation for protection from theft and surveillance of store and switchyard equipment
-
-
-
... More
Providing and fixing of outdoor Static (Bullet) IP 2MP CCTV Network camera having resolution 1920x1080,full HD 1080p video, 140 dB, WDR ,3d DNR smart heater ,Image sensor 1/2.8", progressive Scan CMOS,Shutter time 1/100000 Sec. Day and Night IR cut filter with auto Switch weather proof IP 67 protection,IR range 100-120 Meter Model No DS-2CD4A25FWDIZ(H)(S) of Hikvision make or equivalent model of BOSCH/CAME make.
2
-
-
... More
Providing and fixing of Full HD outdoor Dome IP 2MP CCTV camera having resolution 1920x1080,full HD 1080p video, digital WDR ,3d DNR smart heater ,Image sensor 1/2.8", progressive Scan CMOS,Day and Night IR cut filter with auto Switch weather proof IP 67 protection,IR range 50-70 Meter Model No DS-2CD432F-I(Z)(H)(S) of Hikvision make or equivalent model of BOSCH/CAME make.
1
-
-
... More
Providing and fixing of 16 Channel Embedded plug and play NVR having 16 channel,2TB HD, SupportH.264+& h.264, 6 MP ,Integrated 16 Port PoE, HDMI, resolution 1920x1080p upto 2 SATA Interface, Model No7614NI-E2/16P of Hikvision make or equivalent model of BOSCH/CAME make.
1
-
-
... More
Providing and Fixing of 32" Full HD LED TV (model No KDL-32W700B 80cm) of Sony or equivalent make
1
-
-
... More
Supply and fixxing of 3KVA on -Line UPS with isolation transformer suitable for single phase AC power supply and single phase output AC ,floor mounted type with 120 minut power backup APC make (modal No.SURTD3000XLI) or equivalent modelof standerd make.
1
-
-
... More
Providing & fixing of 4TB Hard Disk of seagate make for storing the servilance data.
1
-
-
... More
Providing & fixing of power supply board 24 Volt DC/24Amp AC of standard make.
2
-
-
... More
Porviding & fixing of Power Over Eathernet (POE) Switch (08 Port), 10/1000 MBPS of D-Link make model No. DGS-1210-10P (08 Port) 10/100/1000 MBPS
1
-
-
... More
Providing & laying 40 mm dia size HDPE pipe of standard make for laying of power supply cable/OFC/CAT-6 Data cable as per requirement.
650
-
-
... More
Providing & laying of RG-60 3 GHZ Co-axial optical fiber cable of Fonolex/Standard make for CCTV wiring.
800
-
-
... More
Providing & laying of Cat-6 Data Cable of D-link make for connecting PTZ Cameras to NVR.
240
-
-
... More
Providing & laying of 3 Core 1.5 Sq. mm Multi Strnad Copper Wire Power Cable of Finolex/Standard make as per IS alongwith providing & fixing of Junction Boxes whereever required.
900
-
-
... More
Providing of Computer Table of Godrej make as per sample.
1
-
-
... More
Earthing of Cameras & NVR as per technical specification (01 Job each)
3
-
-
... More
Work related to supply & installation of Fire Detection System operating on the basis of feedback by Smoke Detectors in BCUs, Store, ACDB room, Battery room, & office building at 132 KV substation Indira Nagar Lucknow
-
-
-
... More
Supply & installation of 08-12 Zone Conventional fire detection and fire alarm system with power supply arrangement. (Make compatible with IS: 2189:1999 tested by ERTL (N) and System Sensor (Agni suraksha/ Agni devices/ daksh OR equivalent).
1
-
-
... More
Supply & installation of Manual Call Point A breakable glass cover fixed in such a way that the actuating push button is kept depressed as long as the glass is intact and released when the glass is broken. A small steel hammer shall be attached to the assembly with a steel chain to facilitate breaking of glass. The manual call points shall be suitable for surface or fully / partly recessed mounting. 5mm high red painting/printed word "IN CASE OF FIRE BREAK GLASS" shall be provided on the front face. The manual call point shall be compatible with all conventional control panels. (Make Agni Suraksha (ASES) / Safeway Equivalent Agni Devices).
2
-
-
... More
Electronic hooter 11 dB/24V DC with strobe (ABS-V) The enclosure should be 1.5 mm thickness duly painted and marked "FIRE ALARM". All hooters shall produce a similar sound and shall maintain the same during their operation. (Make Agni Suraksha (ASES) / Safeway Equivalent/ Agni Devices).
2
-
-
... More
Providing & Fixing of lonisation type Smoke Detectors The detector while sensitive to all type of smokes will be insensitive to ambient lights, air drafts, and changes within the operating temperature and voltage ranges. The Detector shall meet the requirements of either EN 54/ FM/ UL or LPC and shall be specifically approved by FM/ UL/LPCB. Apollo / System Sensor /Edward/Bosch.
15
-
-
... More
Providing & Fixing of Optical Smoke Detectors The detector while sensitive to all type of smokes will be insensitive to ambient lights, air drafts, and changes within the operating temperature and voltage ranges. Specially to be installed in cable gallery. The Detector shall meet the requirements of either EN 54/FM/UL or LPC and shall be specifically approved by FM/ UL/ LPCB. (Make Apollo / System Sensor/Edward / Bosch)
6
-
-
... More
Providing & Fixing of Heat Detectors (for the area like Battery room, AC plant area, DG room, etc) It is a combination of rate of rise and fixed temperature principle using thermistor and with automatic compensation for changes of ambient conditions. The thermal detectors are tested and approved to EN54 part 5 (2000) Class A1R Apollo / System Sensor / Edward / Bosch/Agni suraksha.
2
-
-
... More
Providing & Fixing of Response Indicator Lamp assembly consisting of lamp holder and lamp shall be suitable for mounting on walls, partition etc. The housing shall be suitable for surface/flush mounting of 1.5mm thick sheet steel and the facia 3mm acrylic mounted outside a cabin, and directly connected to the detector inside the cabin. In normal circumstances the lamp should flicker but in the event the detector inside the cabin senses a fire, the lamp should glow.
8
-
-
... More
Supply and laying 2x1.5sqmm PVC insulated and sheathed stranded copper wire. Wiring for fire alarm system in general shall comply with IS: 2189 and IS: 732 amended up to date. The detectors shall be wired by ISI marked 1.5 sq mm PVC insulated stranded FRLS copper conductor wires of 1100 volts grade as required and desired on site. Crimping type of lugs are also included in the rates of laying wires and its connections.PVC insulated copper conductor wires shall confirm to IS: 694. And, PVC insulated copper conductor armoured cables should confirm to IS: 1554 (part-1). Make National/Plaza/Kalinga or any other standard make
375
-
-
... More
Supply and laying 4x1.5sqmm PVC insulated and sheathed stranded copper wire. Wiring for fire alarm system in general shall comply with IS: 2189 and IS: 732 amended up to date. The detectors shall be wired by ISI marked 1.5 sq mm PVC insulated stranded FRLS copper conductor wires of 1100 volts grade as required and desired on site. Crimping type of lugs are also included in the rates of laying wires and its connections. Make National/Plaza/Kalinga or any other standard make
345
-
-
... More
Supply and installation of SMF Batteries with suitable rating as required for 24 Hours backup from Exide / Standard / Amco Prestolite/any other standard make.
4
-
-
... More
Signage with backlit facility for Control building marking for various Fire / emergency exit points.
3
-
-
... More
Supply and laying of Ms/PVC conduit pipe 25mm as per Requirement of site.
220
-
-
... More
Provising, fixing & installation of different types of boards i.e. Glow Sign Board, Shutdown Notice Board, Instruction Board etc as detailed bwlow , to be carried out at 220KV substation Kursi Road Lucknow as per specifications and directions of supervising engineer:
-
-
-
... More
Providing, fixing and installation of Glow Sign Board of size 8 ft x 6 ft for substation single line diagram to be fixed in control room building of the substtaion. The Glow Sign Board should be illuminated using sufficient number of LED tube lights. The board shall be made of ACrilic sheet and shall be provided with back support frame & fixing arrangement.
1
-
-
... More
Providing, fixing and installation of Glow Sign Board of size 8 ft x 6 ft for substation Name & Address to be fixed on top of control room building of the substaion. The Glow Sign Board should be illuminated using sufficient number of LED tube lights. The board shall be made of ACrilic sheet and shall be provided with back support frame & fixing arrangement. The board shall be fixed on frame of size 50mm x 06mm and fixed on roof with the help of bricks and CC of stone & concrete , cement & coarse sand for holding the frame and board firmly.
1
-
-
... More
Name plates made of 2mm thick Aluminium Sheet covered with 3 M HIP retro reflective sheet of following size with details / name written by 3M HIP Retro reflective sheet as per prescribed color scheme to be fixed with the help of nuts & bolts at already installed equipment structure in switchyard with all cost of plates, nut-bolts, misc materials, T&P and labour as per specificatins & directions of supervising engineer:
-
-
-
... More
300mm x200mm
25
-
-
... More
450mm x 250mm
15
-
-
... More
500mm x 250mm
10
-
-
... More
R,Y,B phase plate sets consisting of one plate of red,, yellow, blue colors in each set & plates of dia 250mm duly made of 2mm thick aluminium sheet with face to be fully covered in red , yellow, blue phase colors in 3 M HIP retro reflective sheet and the phase plate set to be fixed with the help of suitable size G.I. bolts, nuts on already installed equipment structure etc at the substation.
22
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%