Uttar Pradesh Power Transmission Corporation Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date26 Jul 2024
Closing Date23 Aug 2024
Tender AmountRefer Documents
Costs
EMD
₹ 11,000Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UPTCL_941139_1Bid Award Id
ViewTender No
ETC-12/2024-25Tender Authority
Uttar Pradesh Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://https://upenergy.in/upptcl
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Erection of 132 KV LA and other associated works.
3
9000
3000
Dismentalling of 132 KV LAs with associated works.
3
6000
2000
Dismentalling of 20 MVA Transformer including its radiators, conservator tank turrets, HV/LV/Neutral bushings, connection pipe lines, cooling fans OLTC Drive mechanism box marshaling box, OTI , WTI, Capilary tubes etc.
1
20000
20000
Shifting of main tank of the 20 MVA transformer from its plinth upto 20 Meter distance including turing of the tank if required, Including all T&P and other works required to complete the job satisfectory as per instruction of supervising engineer.
1
19990
19990
Additional Shifting of main tank of the above 20 MVA transformer upto Approx 50 Meter Distence ( 1Job For every 5 meter or part)
10
29900
2990
Shifting of main tank of the 40 MVA transformer to its plinth from place of unloading point (Up to 20 Mtr.) including turing of the tank if required.
1
25000
25000
Additional Shifting of main tank of the above 40 MVA transformer upto Approx 25 Meter Distence ( 1Job For every 5 meter or part)
5
14950
2990
Complete erection of the 40MVA Transformer including its radiators, conservator tank turrets, HV/LV/Neutral bushings, connection pipe lines, cooling fans OLTC Drive mechanism box marshaling bos OTI , WTI, Capilary tubes etc. and its associated works.
1
25000
25000
Commissioning of the air cell in conservator tank of above 40 MVA T/f by providing and filling of dry N2 in it up to specified pressure (as per requirement)
1
22000
22000
Jumpering of equipments of 40MVA Transformer bay (LV and HV side) with the help pf ACSR panther conductor or ACSR Mosse conductor as required after due cutting of conductors of appropriate size to connect the bus bar conductor of main bus & tranfer bus with equipements, transformer etc and equipment to equipement with the help of suitable clamps/connectors including, cutting bending shaping etc of the conductor as per site requirement.
1
9999
9999
Centrifuging of the transformer oil, filled in oil tanker, un-interrupeted till the desired BDV value of the oil is achieved, filing of centrifuged transformer oil into tank and radiators, of the above 40 MVA Transformer from the oil tanker then centrifuging & circulation of the tranformer oil in transformer with the help of centrifuging machine, un-interrupted till the desired BDV values of the transfomer oil and IR values are achieved including recording of the parameters such as tempreature, vacuum, insulation resistance, BDV etc,at every 2 Hrs.
20000
40000
2
Transformer oil sample collection, testing of transformer oil at CPRI/ERDA/Other lab Noida/Bhiwadi & furnishing test report for :-
a- Dissolve Gas Analysis test-01 Nos.
b- Breakedown Voltage Test-01 Nos.
c- Water content
1
20000
20000
Making of delta for neutral earting by fabrication of 3 nos 3 meter long electrodes of 36/40 mm dia M.S round bar, its piercing under the ground at equal diatance of 1 meter at 700 mm depth by digging of earth and connecting all the 03 no electrodes with 75mmx10mm size M.S Flate and taking out the M.S Riser by cutting, bending welding etc, of the M.S Flate (1 Job per detla) (If required)
2
17998
8999
Earthing of equipment by cutting straightening , bending, laying up to 700mm below inside ground & above ground of following size M.S Flate for diagonal/double earthing of the main & aux. structure, equipments structure, transformer body, OLTC pennel, Marsalling box and its neutral point including welding with main earth mat and with object to be earthed, excavation of trenches soil its back filling to complete the work etc.painting with one coat of red oxide then two coat of of green enameld good quality paints as per detail below:
-
-
-
1) 75x10mm size MS Flat
100
5000
50
2) 50x6 mm xize MS Flate
50
2500
50
Laying & properly dressing( with the help of aluminium strips and clamping of tags for identification) of following sizes control cables in cable trenches from transformer control & relay panel, ABT Meter cubicle, RTCC panel in control room to equipments like transformer, T/F marshalling box, 132 KV Circuit breaker, CT, PT, etc. in swichyard as per cable schedule including shifting of cables in drums from storage place at the sub station to erection site and shifting back the balance cables to stores at the sub station .
-
-
-
2C X 2.5 sqmm
1
5000
5000
4C X 2.5 sqmm
2
10000
5000
6C X 2.5 sqmm
2
10000
5000
10C X 2.5 sqmm
0.5
2500
5000
Termination of following sizes laid control cables extending D.C Supply from DCDB and A.C supply from ACDB to TBC panel & equipments (like CB etc) including drilling of holes, providing & fixing of cable glands, ferrules & crimping of lugs, Including shifting of material from storage place at the sub station to erection site and shifting back the balance mateial.
-
-
-
2C X 2.5 sqmm
35
770
22
4C X 2.5 sqmm
100
2200
22
6C X 2.5 sqmm
35
770
22
10C X 2.5 sqmm
25
550
22
Electrical safety processing fee needed for providing all relevant safety clearance documents from electrical safety deparment for energization of the above commissioned 40MVA transformer and its associated bays (amount in approximation)(Note : the amount payable shall actual amount of challan or quoted rate, whichever is lower)
1
27500
27500
Testing of following tests with associated work by NABL approved company/firm on Transformer at the substation from where transformer is to be dispatched with reputed and callibrated testing equipments and providing results in standard format.
-
-
-
Tan delta and capacitencemesuement of Bushing. Tan delta and capacitencemesuement of winding.
1
20000
20000
Sweep frequency Response Analysis (SFRA)
2
10000
5000
Truns ratio measurment on all taps.
1
5000
5000
Winding resistance measurement at all taps.
1
5000
5000
Insulation resistance including polarisation index
Insulation resistance test on core-frame
1
7000
7000
Short circuit test on low voltage on three taps
1
6500
6500
Magnetising current test on low voltage on three taps
1
6500
6500
Magantic balance on low voltage
1
6500
6500
Vector group test
1
6500
6500
Providing and fixing 120Watt LED of new generation energy saving & environment friendly long life versatile pressure die-cost aluminium outdoor high beam flood source & exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 V AC supply of IS make of CGL/Havells/Phillips/Bajaj brand.
30
231000
7700
Providing and fixing of junction box of 16 SWG MS sheet duly painted size 150*150*200 mm for above light on the bottom of main structure with the help of clamps, junction fix contains 01 no. 05 Amp single pole MCB ( L&T, Havells, Siemens make ) with 01 no. link as per technical specifications
20
22000
1100
Laying, dressing and termination of control cable for the gantry light with the help of clamps,vertically on gantry & all other associated work.
300
2400
8
Providing and fixing of phase plate ( R,Y,B )
15
6600
440
Providing and fixing of name plates for various equipments make of 2 mm thick aluminium sheet with covering of 03 mm retro reflective sheet with various size .
-
-
-
a) 600*300 mm
10
8250
825
Repairing of cooling fan of 40MVA T/F. Work including winding of motor, replacement of bearing and other associated work.
4
22000
5500
Painting of ms flat with one coat of red oxide and then two coat of green enamiled good quality paint as per site requirement. (Paint will be provided by contractor)
500
11500
23
Transportation
-
-
-
Loading of 40MVA T/F tank including all accesssories on trailor/trucks . The job include jacking the transformer tank for placing the wooden sleepers under the tank and simultaneously lifting the tank by jacking and placing sleepers continusaly under the tank till the wooden plateform comes in the allignment of trailor bed and then shifting the tank from wooden plateform to trailor bed. removal of rails etc. from under the tank, proper tightening of tank on trailor bed with the help of wire rope and heavy turn buckle for safe trasporatation.
1
34000
34000
Unloading the 40MVA T/F tank including all accessories from trailor/trucks and there proper stacking at the desiganated place at 132kv S/S Hasayan. The job includes opening of laces, jacking the transformer tank and placing the rails under the tank, shifting it to wooden sleepers plateform to be prepared adjacent to the trailor, removing the rails from under the tank on wooden plateform of sleepers, lowering the tank towerds grounds by slowely removing the sleepers from under the tank.
1
29000
29000
Safe carriage of 132/33 KV, 40MVA Transformer from any Substation of UPPTCL to 132 KV Substation Hasayan Hathras. (Distence Aprox-180KM). The insurance shall be got done by contractor as per direction of supervisining engineer at his own cost.
1
202000
202000
Supply component :
-
-
-
Supply of 75x10mm MS Flat for Grounding/Earthing System
50
18166
363.33
Supply of 50x6mm MS Flat for Grounding/Earthing System
100
15225
152.25
Supply of 40mm dia MS electrode of 3 metre length
25
54162
2166.5
Supply of 63 amp power contactor, Schneider, L&T, ABB, Siemens make, 03 pole, 230 volt AC auxiliary supply as per sample.
2
6780
3390
Supply of 25 amp power contactor,Schneider, L&T, ABB, Siemens make, 03 pole, 230 volt AC auxiliary supply as per sample.
4
7456
1864
Supply of 25 amp power contactor,Schneider, L&T, ABB, Siemens make, 03 pole, 110 volt DC auxiliary supply as per sample.
2
2508
1254
Note-
-
-
-
1.GST shall be paid EXTRA as per rules.
-
-
-
2.Bidders have to submit their % Rates above or below the Estimated Rates (Excluding "%" symbol in "Blue Box" only).
-
-
-
3.Bidders will submit their Rates by putting "X" for "X"% of Higher than Estimated Rates (ie.will put simply 1 for quoting 1.0% higher than Estimated Rates)
-
-
-
4.Bidders will submit their Rates by putting "-X" for "-X"% of Lower than Estimated Rates (ie.will put simply -1 for quoting 1.0% lower than Estimated Rates)
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements