Uttar Pradesh Power Transmission Corporation Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Aug 2024
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Work Related To Tan Delta, Pd Testing Etc. Of Ct/pt Of Different Voltages Established At Various

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender Document, Details for EMD, Tender Cost Copy of UTR No and Pay in Slip of Transfer of Money through RTGS or NEFT, Experience etc. as per NIT
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
200 MVA 220/132/11 kV T/F (Aaditya Make)

1

-

-

... More
160 MVA, 220/132/11 kV T/F (EMCO Make)

2

-

-

... More
63 MVA, 132/33 kV T/F (TAL Make)

1

-

-

... More
40 MVA, 132/33 kV T/F (Kanohar Make)

1

-

-

... More
40 MVA, 132/33 kV T/F (TAL Make)

1

-

-

... More
Testing of Current Transformer (Tan Delta, IR Value,CT Ratio and Other )

-

-

-

... More
Testing of CTs with the help of duly calibrated Test Kits to be arranged by the contractor including the cost of carriage and operation of Test kit including preparation and submission of test results in specified formats after the completion of tests. The tests shall include capacitance and Tan Delta measurement (to be conducted by duly calibrated OMICRON/Megger make Test Kit) and Polarity check, current ratio and knee point voltage test (to be conducted by duly calibrated OMICRON/Megger make CT Analyser) and IR Value (5KV). The works shall include the cost of Manpower involved in testing and submission of test reports in specified formats. The tests shall be conducted in accordance with the technical specifications mentioned in Annexure-1

-

-

-

... More
245 kV Current Transformers of various 220 KV Bays

36

-

-

... More
Partial Discharge Test of various , 220 KV & 132 KV Current Transformers.

-

-

-

... More
Partial Discharge test by both EHF (Extra High Frequency) and HF (High Frequency) methods with help of duly calibrated test kit. The work also includes the cost of carriage and operation of Test kit including preparation and submission of test results in specified formats after the completion of tests. The test results should clearly mention the Health of CT's and suggestion for Action to be Taken regarding the same.

-

-

-

... More
245 KV Current Transformers of various 220 KV Bays at 220 KV S/S Shahjahanpur

36

-

-

... More
132 KV Current Transformers of various 132 KV Bays at 220 KV S/S Shahjahanpur

56

-

-

... More
132 KV Current Transformers of various 132 KV Bays at 132 KV S/S Shahjahanpur

27

-

-

... More
132 KV Current Transformers of various 132 KV Bays at 132 KV S/S Powayan

21

-

-

... More
Carriage & Visit Charges

-

-

-

... More
Carriage and Visit Charges shall include the cost of carriage of all The test kits required for testing activities in a particulars bay including testing of Transformer/Reactors/CBs,CTs,CVTs. All the test required in a particular bay shall be completed in a single visit as per availability of shutdown. Note- Visit will only be counted if there is gap of more that two days between succesive visit otherwise it will be counted as a single visit.

14

-

-

... More
Following works are to be conducted for routine annual testing of various bay equipment in 220 KV bays, at 220 KV S/S, Hardoi, Mallawan & 132 KV Sandila, Shahabad, Baghauli, Shrimau, Asha

-

-

-

... More
Capacitance and Tan Delta Measurement

-

-

-

... More
Tan Delta and capacitance measurement of ICTs as per standard testing procedures (Including Tan Delta and Capacitance Measurement of Bushings at standard and variable frequencies and that of HV & LV windings) with the help of duly caliberated Tan Delta Test Kit of OMICRON/Megger make to be arranged by the contractor including the cost of operation of Test Kit along with preparation and submission of test results in specified formats after the completion of tests. The works shall include the cost of Manpower involved in testing and submission of test reports in specified formats. The tests shall be conducted in accordance with the technical specifications mentioned in Annexure-I

-

-

-

... More
160 MVA 220/132 kV ICT-01 (EMCO Make) Hardoi

1

-

-

... More
160 MVA 220/132 kV ICT-01 (T&R Make) Hardoi

1

-

-

... More
63 MVA, 132/33 kV T/F-I (TAL Make) Hardoi

1

-

-

... More
40 MVA, 132/33/11 kV T/F-II (Bharat Bijli Make) Sandila

1

-

-

... More
Testing of Current Transformer (Tan Delta, IR Value,CT Ratio and Other )

-

-

-

... More
Testing of CTs with the help of duly calibrated Test Kits to be arranged by the contractor including the cost of carriage and operation of Test kit including preparation and submission of test results in specified formats after the completion of tests. The tests shall include capacitance and Tan Delta measurement (to be conducted by duly calibrated OMICRON/Megger make Test Kit) and Polarity check, current ratio and knee point voltage test (to be conducted by duly calibrated OMICRON/Megger make CT Analyser) and IR Value (5KV). The works shall include the cost of Manpower involved in testing and submission of test reports in specified formats. The tests shall be conducted in accordance with the technical specifications mentioned in Annexure-1

-

-

-

... More
245 kV Current Transformers of various 220 KV Bays at 220 kV S/S Hardoi & 220 KV S/S, Mallawan

12

-

-

... More
Partial Discharge Test of various, 220 KV & 132 KV Current Transformers.

-

-

-

... More
Partial Discharge test by both EHF (Extra High Frequency) and HF (High Frequency) methods with help of duly calibrated test kit. The work also includes the cost of carriage and operation of Test kit including preparation and submission of test results in specified formats after the completion of tests. The test results should clearly mention the Health of CT's and suggestion for Action to be Taken regarding the same.

-

-

-

... More
245 kV Current Transformers of various 220 KV Bays at 220 kV S/S Hardoi & 220 KV S/S, Mallawan

18

-

-

... More
132 KV Current Transformers of various 132 KV Bays at 132 kV S/S Hardoi, Sandila, Shahabad, Shrimau, Baghauli, Asha, & 220 KV S/S, Mallawan

70

-

-

... More
Carriage & Visit Charges

-

-

-

... More
Carriage and Visit Charges shall include the cost of carriage of all The test kits required for testing activities in a particulars bay including testing of Transformer/Reactors/CBs,CTs,CVTs. All the test required in a particular bay shall be completed in a single visit as per availability of shutdown. 1. 220 kV SPN Bay 3 Nos 220 kV CT 2. 220 kV Mallawan bay, 3 Nos 220 kV CT 3 160 MVA T/F-I bay 3 Nos 220 kV CT 4. 160 MVA T/F-II Bay 3 Nos 220 kV CT 5. 220 KV PGCIL Bay 3 Nos. 220 kV CT 6. 220 kV Hardoi bay 3 Nos 220 kV CT 7. 220 kVJehta ckt I Bay 3 Nos 220 kV CT 8. 220 kV Jehta ckt II Bay 3 Nos 220 kV CT 9. 220 kV TBC bay 3 Nos 220 kV CT 10. 160 MVA T/F-I Bay 3 Nos 220 kV CT 11 .160 MVA T/F-II Bay 3 Nos 220 kV CT Note- Visit will only be counted if there is gap of more that two days between succesive visit otherwise it will be counted as a single visit.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.