Uttar Pradesh Power Transmission Corporation Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date5 Mar 2024
Closing Date13 Mar 2024
Tender Amount₹ 35,37,000
Costs
EMD
₹ 35,000Document Cost
₹ 4,130Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UPTCL_911660_1Bid Award Id
ViewTender No
E-Tender No. 71-ETC(G)/2023-24Tender Authority
Uttar Pradesh Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://https://upenergy.in/upptcl
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling & Re-erection of 145 KV LA along with structure (if required)) by opening of nut and bolt, opening of jumper also removal of earthing and safe shifting of Equipment with all part and all other associated work.
3
-
-
Dismantling of old 100 MVA T/F and accessories removing the Radiator, conservator tank, A frame, header, bushing, pipe line, and pump. Cooling fan and all other accesories etc. and drain out of oil up to required level into empty oil drums and cover by bushing blanking plate (provided by contractor) at 220KV S/S Hata Kushinagar.
1
-
-
Shifting of 100MVA T/F main tank from plinth to near 20 mtrs.
1
-
-
A-Additional shifting 130Mtr. @5mtr. /Job
26
-
-
Shifting & placement of all dismantled accessories as radiator, conservator tank and other accessories to store /open switchyard and proper stacking (AS PER INSTRUCTION OF SUPERVISIOR)
1
-
-
Shifting of 160MVA T/F main tank from unloading place to existing T/F plinth by dragging distance about 20Mtrs.
1
-
-
A-Additional shifting 140Mtr. @5mtr. /Job.
28
-
-
Providing of dry air at the time opening of blanking plate for erection of 160 MVA T/F main tank and filling of dry air of dew point -400 C or better for completion of work. The work shall including connecting pipe as required measuring dew point valued of dry air.
1
-
-
Filling the T/F oil in oil tank and its centrifuging up to required BDV and creating the vacuum inside the 160MVA T/F Before filling the T/F oil inside the main tank.
1
-
-
Complete erection of 160MVA T/F and accessories of HV/LV/TV side bushing, radiator, and Conservator tank. Frame, Header, pipe line, pump cooling fan etc. and top up required level.
1
-
-
Complete Evacuation of 160 MVA T/F main tank and filling of dry air /N2 of dew point-400C or better in vacuum up to pressure of 0.25kg/Cm2 and the again evacuating the T / F tank after required time interval 3 (Approx. 12/24 Hrs.) using centrifuging machine. The work shall including connecting pipe of machine as required measuring due point values of dry air after every cycle till the required value is achieved.
3
-
-
Centrifuging of complete T/F oil in T/F by connecting centrifuging pipes circulating the T/F oil through centrifuging machine and taking the BDV value of the oil periodically till the required value is achieved as per 4 direction of supervising engineer, the work includes all the work related to centrifuging the oil and filling the oil in T/F and tank. Oil approx... 50KL (operator and centrifuging machine shall be arrange by the contractor)
1
-
-
Laying, dressing and binding of cable including fixing of cable tray support structure and termination of cable marking the top and its ferruling as per schedule and inter connection including shifting of old cable as per requirement of RTCC panel, marshalling box, driving mechanism etc. and replacement of cable from control room to Marshalling Box as per instruction of supervisior.
1
-
-
Earthing of T/F body, MB DM Box, OLTC, RTCC at two points using S 75x10 / 50x6mm M.S flat for 40mm M.S rod to be provided by the department free of cost.
1
-
-
Painting of earthing strip above the ground level by one of red oxide and two coat of bus green paints.
75
-
-
Preparing and fitting of ACSR Moose/Zebra conductor jumper of 220KV and 132KV side cutting of conductor and fixing of equipment (approx. 12 Nos. Jumper)
1
-
-
Special Delta earthing for 160MVA T/F consisting of fabrication of delta set with 3Nos. 40mm/36mm dia size 6Mtrs. Long electrodes its placing inside the ground and connecting all the three electrodes with 75x10mm MS flat 700mm deep and connecting the same with earthmat at two places (M.S flat and M.S rod arrange by the Department)
2
-
-
Carriage of oil tanker 40/20KL including loading, unloading and carriage approx. distance 50 km
1
-
-
Conducting oil test of oil sample by arranging appropriate equipment for following testing by NABL Lab (BDV/PPM, DGA/etc.) as per instructin of supervisior and also assistance in the T/F testing, main tank, r,y,b-phase oltc sample
2
-
-
NOTE: NOC has been taken by contractor from electrical safety department and it will reimburesed on actual amount after submitting. challan copy with bill to department
-
-
-
For Installation of emulsifier for replacement of 160MVA T/F 220KV S/S Hata Kushinagar.
-
-
-
Supply & laying upper ground as required of different size MI pipe B class Jindal/tata make for fire direction water pipe line support as per IS Specification (IS code-1239) as per drawing enclosed complete with elbow tee socket reduce nuts and bolts with detail as below with anticorrosive treatment or painting as where required along with fabrication & fixing of L & U shape support with associated work to complete the job in all respect
-
-
-
65 NB
30
-
-
50 NB
20
-
-
25 NB
60
-
-
Supply & installation of 80 NB MS pipe B class Jindal/tata make for making support running of water lair pipe line including providing flange on bottom & its proper grouting with fastener as where required.
35
-
-
Supply & installation of flanges as per IS-1538 of different size as per 3 drawing work include proper butt welding with pipe & proper packing and coupling with nus & bolts and fastener as required
-
-
-
150 NB
5
-
-
80 NB
30
-
-
65 NB
25
-
-
50 NB
25
-
-
25 NB
34
-
-
Supply & Installation & commissioning of high velocity water spray nozzles flow capacity 305 kg /Cm spray angle 9
55
-
-
Supply & installation & commissioning of Quartzite bulb detectors (QBD) operator as 76 C° sensing at rated temperature for actuation of the element 10/12 sec.
90
-
-
Supply & installation & commissioning of gate valve as per technical specification (IS Code 14846) 150 NB.
1
-
-
Supply & installation & testing commissioning of fixed different switch (danfoss/Indfoss make) type pressure switch range 1-10 Kg./Cm².
2
-
-
Pressure Gauge as per IS specification IS Code 3624 accuracy +-5%
2
-
-
Dismantling & installation including repairing of deluge valve by replacement of gasket & repairing of sheet repairing of alarm electrical connection of pressure switch including of control cable etc.
1
-
-
Laying of upper ground as required of 150 NB old & use including modification as required MS pipe B class provided by deptt. For fire water pipe line support as per IS specification (IS code-1239) as pre drawing enclosed complete with elbow tee socket reduce nuts & bolts (provided by deptt.) with detail as below with anticorrosive terminate or painting as where required along with fabrication & fixing of L&U shape support with associated work to complete the job in all respect. 150 NB.
5
-
-
Supply & laying upper ground of different size old & used including modification as required Gl pipe B class (provided by the deptt.) for fire detection with anticorrosive terminate or painting as where required along with fabrication & fixing of L&U shape support with associated work to complete the job in all respect. 65 NB.
45
-
-
50 NB
25
-
-
25 NB
50
-
-
Re-installation of old & used including modification as required of MS pipe B class (provided by deptt.) by for making support running of water air/pipe line including providing flange on bottom & its proper grouting with fastener nut, bolt with anticorrosive treatment or painting as where required.a)-25 mm dia b)50 mm dia c)65 mm dia d)80 mm dia
200
-
-
Re-installation & commissioning of old & used high velocity water spray nozzles flow capacity 3.5 Kg./cm2 spray core angle 90 (provided by deptt.)
80
-
-
Re-installation & commissioning of old & used of Quartzite bulb detectors (QBD) operate at 760 C sensing at rated temp for actuation of the element 10/12 sec. (provided by dept.)
22
-
-
Re-installation & commissioning of 150 NB Deluge valve as per requirement of transformer which includes servicing of related fitting like 150 NB T-Strainer 2 No. gate valve another related parts of deluge valve.
1
-
-
132 KV MAIN BUS BAR STRENGTHING
-
-
-
WORK PART OF 132 KV MAIN BUS BAR STRENGTHING
-
-
-
Opening / cutting of R , Y & B phase of 132 KV existing Main Bus Bar made of Tarantulla conductor between Bus section below gantries, step by step during Bus Bar replacement work including dismantling of all types of associated clamps and fittings.
15
-
-
Dismantling of following existing jumpers from Main Bus Bar and jack bus bar by opening of all associated clamps , step-by-step during Bus Bar replacement work of ACSR Moose/ Zebra/ Panther Conductor of remaining feeders.
60
-
-
Dismantling of 132 KV Old / Damaged Main Bus Bar and Jack Bus Bar section (R , Y & B ) of Tarantulla / Moose conductor and lowering down of conductor from Substation gantry complete dismatling of all associated tension clamps, fittings and disc insulators etc.
15
-
-
Fixing of Double Moose Suspension/Tension fitting under Bus Bar section of Main Bud Bar-I below the gantries with suitable hardware such as hoisting of disc insulators etc. to complete the work in all respect satisfactorily.
39
-
-
Stringing and proper sagging of new 132 KV Main Bus Bar- I Jack Bus Bar section ( R, Y & B) by twin Moose conductor the work including fitting of tension clamps, hoisting of 70/120 KN Disc , tension fitting, spacers , PG Clamps etc. and cutting of conductor as required.
15
-
-
Reconnection of R, Y & B phase of 132 KV Main Bu Bar-I of twin Moose conductor between Bus section below gantries , step- by- step during Bus Bar replacement work including joining of Moose conductor below the gantries with the help of suitable PG Clamps through the Quadruple suspension fittings and spacers etc. and cutting of conductors as required.
15
-
-
Reconnecting new jumpers between bus and bays after fixing of spacers, clamps as required . Jumper can be ACSR Moose / Zebra/ Panther Conductor of remaining feeders.
60
-
-
Replacement of damaged jumpers of different bays in the 132 KV Switchyard after opening of damaged on and re-fixing of healthy one with the help of suitable PG Clamps etc. and cutting of conductor as required.
20
-
-
SUPPLY PART 132 KV MAIN BUS BAR STRENGTHING
-
-
-
Bolted type tension fitting for twin moose conductor with turn buckle for 132KV Main Bus Bar suitable for each disc having 16 Nos. 120KN disc insulators with hardware fitting D-shacle, york plate, ball hook, D-clip, tension clamp etc. as per technical specification.
17
-
-
Bolted type tension fitting for twin moose conductor without turn buckle for 132KV main bs bar-I suitable for each disc having 16 Nos. 120KN disc insulators with hardware fitting D-shacle, D-shocket, york plate, ball hook, D-clip, tension clamp etc. as per technical specification.
17
-
-
Suspension fitting for twin moose conductor with york plate complete assembly as per technical specification.
12
-
-
132KV Bus post insulator connector for ACSR moose conductor as per technical specification.
15
-
-
4 bolt type PG clamp made of alluminium alloy LM-6 with spring washer along with GI bolts and nuts suitable for moose to moose.
240
-
-
4 bolt type PG clamp made of alluminium alloy LM-6 with spring washer along with GI bolts and nuts suitable for moose to zebra.
40
-
-
02 bolts 250 mm spacing , spacer for twin moose conductor as per technical specification.
200
-
-
Heavy duty (alluminium alloy) isolator terminal connector suitable for twin moose 132KV isolator.
45
-
-
Note :- All the items which rate is not given in cost data book, for which rate is taken from previous agreements which reference is given above.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements