Uttar Pradesh Power Transmission Corporation Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender
Eprocure
Opening Date16 Jan 2025
Closing Soon24 Jan 2025
Tender Amount₹ 10,23,500
Costs
EMD
₹ 11,000Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_UPTCL_993854_1Tender No
T-09/24-25/ETC/MTTender Authority
Uttar Pradesh Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://https://upenergy.in/upptcl
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
33 Lighting Arrestors
1
-
-
... More
Power Cable and termination kit
-
-
-
... More
Complete testing of already erected HV Side termination kit IR test, VLF with stand test, Hi-Pot test, Sheath integrity test.
1
-
-
... More
Erection of Outdoor termination kit for 36 KV, 1CX630 sq mm XLPE copper cable including bushing arrangement for connecting 33 KV Sides of 63 MVA T/f with XLPE Cable.
6
-
-
... More
Laying and Termination of following size control cable in trench/cable trays from different control room equipment to 132/33 KV Isolator, circuit breakers CT/PT & their junction boxes. Transformer marshaling box. Isolator box & other outdoor equipment’s installed in 132/33 KV switch yard as per cable schedule. Including carriage of cable drum from store and all other associated work.
-
-
-
... More
Control cable of size 2 core x 2.5 mm2.
420
-
-
... More
Control cable of size 4 core x 2.5 mm2.
1310
-
-
... More
Control cable of size 6 core x 2.5 mm2.
950
-
-
... More
Control cable of size 10 core x 2.5 mm2.
630
-
-
... More
Termination of cable laid as per cable schedule including making necessary hole in laid plates or box wherever required, fixing cable glands of appropriate size and ferruling of each core and other associated work to complete the job satisfactorily. Rates of termination of control cables including the all cores of cable and one end with lugs. Note:- Gland & lug provided by Contractor
-
-
-
... More
2 Core
8
-
-
... More
4 Core
30
-
-
... More
6 Core
20
-
-
... More
10 Core
20
-
-
... More
Shifting of damaged 63 MVA transformer from plinth to safe place upto 30 mtrs distance (each job 20 mtr , 1.5 jobs) including turning (if required) including all T and P and work required to complete the job satisfactorily.
1.5
-
-
... More
Installation work of 63 MVA Transformer.
-
-
-
... More
Dragging of 63 MVA Transformer from unloading point to the plinth up to 45 Mtr distance including turning of tank if required including all T & P and labour required to complete the job satisfactorily.
2.25
-
-
... More
Complete erection of 63 MVA 132/33 KV Transformer by erection of radiator, conservator tank, bushing with its turrets, connecting of all oil pipe lines, cooling fans, making control cable connection, buckholz relay etc. for completing the work topping transformer oil and final oil filling in tank radiator conservator tank and all other associated work for completion of work
1
-
-
... More
Circulation of complete Transformer oil in Transformer tank through centrifuging machine, centrifuging machine shall be provided by the contractor, oil capacity (Approx 25 KL)
25
-
-
... More
Replacement of existing old Transformer RTCC Panel by new RTCC Panel by opening of control cable, cutting of earthing termination and laying control, preparation of cable schedule shifting of dismantled panels to else wire as per direction of site incharge.
1
-
-
... More
Delta earthig of HV & LV side neutrals of 63 MVA Transformers by 3 Nos., 3.0 Mtr long electrode of 40 mm M.S. Round Bar having 150 mm long conical shape, placing inside the ground in triangular shape and connection all 3 Nos electrodes with 75x10/50x6mm MS flats then connect this triangle shape with X & Y of main earth mat of Sub-Station as per drawing. Notes:- MS Round Bar & M.S. Flat Shall be provided by Department.
2
-
-
... More
Earthing of main tank of 63 MVA T/F at two points by using MS Flat 50x6/75x10 mm size its jointing with already laid earth mat (x and y electrodes) for its earthing work
1
-
-
... More
Sampling and testing of transformer oil at CPRI testing lab including cost of transportation of each sample in standard sampling bottles (adequate no of bottles to be arranged by the contractor). Samples to be taken at required intervals (as per actual requirement)- Following tests are to be conducted for each sample- 1.Breakdown voltage. 2. Moisture Content
1
-
-
... More
Supply & fixing of new generation energy saving and environment friendly long life versatile pressure die cost aluminum out door high been flood light 120 Watt LED as light source and exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 V input supply for ISI make CGL/Hevells/Surya/Philips/Bajaj of equivalent etc. including electrical connection also to be done by the contractor.
5
-
-
... More
SUPPLY PART: -
-
-
-
... More
Power Cable & Termination Kit
-
-
-
... More
Outdoor type Termination kit for 36KV, 1CX630 sq. mm. XLPE copper cable (For Power Transformers)
6
-
-
... More
Connector & Clamp
-
-
-
... More
132 KV Bus Post Clamp panther for 132 KV LA.
3
-
-
... More
63 MVA,132/33 KV Transformer HV Side Bushing Connector suitable for Panther (01 Set = 03 Nos)
1
-
-
... More
63 MVA,132/33 KV Transformer LV Side Bushing Connector suitable for twin Tarantulla (01 Set = 03 Nos)
1
-
-
... More
33 KV LA Clamp for Twin Tarantulla.
6
-
-
... More
Increasing capacity at 132 KV S/S Kankarkhera: -
-
-
-
... More
Work Portion: -
-
-
-
... More
Modification of 132 & 33 KV Bays of 63 MVA T/F-II (old bay for NEW TF)
-
-
-
... More
Dismantling of old 36KV CTs having ratio (800-400/1A) including opening of jumpers, earthing, N&B, secondary connections etc and shifting from site to store.
3
-
-
... More
Dismantling of old 36KV VCB including opening of jumpers, earthing, N&B, secondary connections etc and shifting it to the store.
1
-
-
... More
Dismantling of old 120 KV Lighting Arrestors (All 3 Phase) including opening of jumpers, earthing, N&B and shifting from site to store.
1
-
-
... More
Dismantling of old 30 KV Lighting Arrestors (All 3 Phase) including opening of jumpers, earthing, N&B and shifting from site to store.
1
-
-
... More
Erection of following equipment as per instruction manual of various equipment’s and technical specification including shifting of material / equipment from store to erection site including all other associated works to complete the job satisfactorily.
-
-
-
... More
36 KV Circuit Breaker
1
-
-
... More
36 KV Current Transformer
3
-
-
... More
36 KV CT junction box.
1
-
-
... More
120 KV Lighting Arrestors
3
-
-
... More
30 KV Lighting Arrestors
3
-
-
... More
Laying and Termination of following size control cable in trench/cable trays from different control room equipment to 132/33 KV Isolator, circuit breakers CT/PT & their junction boxes. Transformer marshaling box. Isolator box & other outdoor equipment’s installed in 132/33 KV switch yard as per cable schedule. Including carriage of cable drum from store and all other associated work.
-
-
-
... More
Control cable of size 2 core x 2.5 mm2
600
-
-
... More
Control cable of size 4 core x 2.5 mm2
600
-
-
... More
Control cable of size 6 core x 2.5 mm2
600
-
-
... More
Control cable of size 10 core x 2.5 mm2
500
-
-
... More
Termination of cable laid as per cable schedule including making necessary hole in laid plates or box wherever required, fixing cable glands of appropriate size and ferruling of each core and other associated work to complete the job satisfactroly. Rates of termination of control cables including the all cores of cable and one end with lugs. Note:- Gland & lug provided by Contractor
-
-
-
... More
2 Core
20
-
-
... More
4 Core
20
-
-
... More
6 Core
12
-
-
... More
10 Core
10
-
-
... More
Dismantling work of 40 MVA Old Transformer.
-
-
-
... More
Opening of jumpers of old 40 MVA transformer, cutting of earthing strips and opening of electrical connections as follows: -
-
-
-
... More
Opening of all HV, LV and 120KV LA jumpers of old 40MVA Transformer
9
-
-
... More
Opening of earthing strips by cutting and opening of electrical connections
1
-
-
... More
Partially drain out the transformer oil from main tank ,after due shifting of drums, pipes etc. with all cost of men, material T&P required for completion of work.
1
-
-
... More
Complete dismantling of old 40 MVA, Transformer by opening of radiator, conservator tank, bushing, marshaling box, cooling fan, etc. and paking of bushing of old 40 MVA TF in crates and shifting the bushing from site to store at 132KV Kankerkhera Substation.
1
-
-
... More
Shifting/Dragging of old 40 MVA T/F from plinth to near open space. Distance about 50 Mtr. including turning of main tank if required with all T&P and work required to complete the job satisfactorily at 132 KV Substation Kankerkhera
1
-
-
... More
Installation work of New 63 MVA New Transformer.
-
-
-
... More
Dragging of 63 MVA Transformer from unloading site to T/F plinth up to 20 Mtr distance including turning of tank if required including all T & P and labour required to complete the job satisfactorily.
1
-
-
... More
Complete erection of 63 MVA T/F by erection of radiators, conservator tank, bushing with its turrets (if available) connecting of all pipe line, erection of cooling fans, making control cables connection, Buchholz relay etc. for competing the work, topping of transformer oil and final oil filling in tank, radiators, conservator tank and all other associates work for completion of work.
1
-
-
... More
Earthing of main tank of 63 MVA T/F, at two points by using M.S. flat 50x6/75X10 mm size, its jointing with already laid earth mat (X&Y Electrodes) for its earthing work.
1
-
-
... More
Replacement of existing old T/F RTCC panel by new RTCC Panel by opening of control cable, cutting of earthing, termination and laying control cables, preparation of cable schedule etc. & shifting of dismantled panel to elsewhere as per direction of site incharge in control room at 132 KV Sub-Station Kankerkhera.
1
-
-
... More
Centrifuging of complete transformer oil in transformer by connecting centrifuging pipes, circulating the transformer oil through private centrifuging machine (To be arranged by the contractor at his own cost) with BDV machine and PPM kit and taking BDV values of oil periodically till required value is achieved (Approx. 22 KL oil)
22000
-
-
... More
Transformer oil sample collection testing of transformer oil at CPRI testing lab including cost of transportation of each sample in standard sample bottles. (after centrifuging of installed 63 MVA TF). 1. Breakdown Voltage Test. 2. Moisture Content Test.
1
-
-
... More
Jumpering of 63 MVA Transformer from HV & LV side with Single Panther /twin zebra work includes cutting of conductor and tightening of conductor with connector.
-
-
-
... More
132 KV side of 63 MVA T/F
6
-
-
... More
33 KV side of 63 MVA T/F
24
-
-
... More
Earthing of T/F MB DM box OLTC, RTCC at two points using 75×10/50×6mm. And nutral of T/F as per drawing using 40 mm M.S. rod after making delta formation with 3 M long electrodes.
1
-
-
... More
Periphery and switchyard lighting
-
-
-
... More
Providing and fixing of junction box on gantry structure with 1 No MS flat 40x5 mm of size 200x200x150 mm made of MS sheet of 16 gauge dully powder coated inside mounting 1 No 6 Amp MCB 1 No TB of 4 terminal & 1 No Kit Kat 16 Amp fixed upon mica sheet and back side mounting a flat 40x5 mm with 1 No 16mm dia hole and mounting PVC pipe from ground level to box as per technical specification.
5
-
-
... More
Supply & fixing of new generation energy saving and environment friendly long life versatile pressure die cost aluminum out door high been flood light 120 Watt LED as light source and exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 V input supply for ISI make CGL/Hevells/ Surya/ Philips/Bajaj of equivalent etc. including electrical connection also to be done by the contractor.
10
-
-
... More
Supply: -
-
-
-
... More
3 Bolted Type PG clamp suitable for Panther to Panther conductor Complete with HDG nut bolt & washer as per technical specification.
21
-
-
... More
4 Bolted Type PG Clamp suitable for Zebra to Zebra conductor complete with HDG nut bolt & washer as per technical specification.
18
-
-
... More
4 Bolted Type PG Clamp suitable for Zebra to Panther conductor complete with HDG nut bolt & washer as per technical specification.
6
-
-
... More
132 KV LA clamp suitable for Zebra conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
4
-
-
... More
36 KV VCB Clamps suitable for ACSR Twin Zebra conductor made of aluminum alloy LM-6 complete with galvanized N&B, spring and plain washers.
7
-
-
... More
36 KV CT Clamps suitable for ACSR Twin Zebra conductor made of aluminum alloy LM-6 complete with galvanized N&B, spring and plain washers.
7
-
-
... More
33 KV LA clamp suitable for Twin Zebra conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
4
-
-
... More
Spacer for 100mm spacing for Twin Zebra Conductor 02 bolted complete with hot dip galvanized nut, bolts & washer as per technical specification.
18
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%