Uttar Pradesh Power Transmission Corporation Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender
Machinery and Tools
Eprocure
Opening Date8 Oct 2024
Closing Date11 Nov 2024
Tender Amount₹ 27,87,366
Costs
EMD
₹ 33,000Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UPTCL_962972_1Bid Award Id
ViewTender No
ET-15/ETC-I(K)/2024-25Tender Authority
Uttar Pradesh Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://https://upenergy.in/upptcl
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Complete Drain out of the Reactor oil from 63 MVAr Reactor with NGR into 209 Ltr empty OIL drum.(approx 28 KL)
1
-
-
... More
Carriage of empty oil drum ( Approx 140 nos) from 220 KV S/S Mainpuri to 400KV S/S PGCIL Mainpuri (approx distance 15 km) by private vehicle, including loading at 220 KV S/S mainpuri and unloading at 400 KV S/S PGCIL Mainpuri end.
1
-
-
... More
Creating the vaccum in main tank, filling N2/dry air of 63 MVAR Reactor Hitachi Make.
1
-
-
... More
Shifting of main tank of 63 MVAR Reactor filled with N2/Dry air from plinth up to 20 meters distances at required place with NGR at 400 KV S/S PGCIL Mainpuri end.
1
-
-
... More
Additional shifting of main tank of 63 MVAR reactor with NGR upto 5meters distance
25
-
-
... More
Loading of 63 MVAR Reactor main tank with NGR along with accessories making the wooden sleeper platform jacking the Reactor tank up to trailor height, placing the rail below the reactor main tank with NGR by stacking and proper tighting of the main tank with trailor bed with the help of steel rope and turn buckle at 400 KV S/S PGCIL mainpuri.
1
-
-
... More
Safe Carriage of 63 MVAR reactor with NGR from 400 KV PGCIL mainpuri to 400 KV S/S Panki kanpur approximate 210 km with all accessories (bushing should be brought carefully in a wooden box) including reactor oil on suitable capacity trailor & truck to be arranged by contractor at his own cost, insurance shall be got done by the contractor at his own cost.
1
-
-
... More
Unloading the main tank with NGR from loaded trailor to suitable place at 400KV S/S Panki Kanpur by jacking the tank for placing the rails, under the tank and shifting it to wooden sleepers platform to be prepared adjacent to the trailer,removing the rails under the tank on platform of wooden sleepers ,lowering the tank towards ground by slowely, removing the sleepers from the tank and unloading of various reactor accessaries of above 63 mvar reactors like NGR, oil filled drums ,bushing,conservator tank radiators etc. from trailor at 400 KV S/S panki kanpur.
1
-
-
... More
Shifting of main tank of 63 MVAR Reactor filled with N2/Dry air from unloading place to plingth up to 20 meters distance with NGR at 400 KV S/S Panki Kanpur Rewa Road Bay end.
1
-
-
... More
Additional shifting of main tank of 63 MVAR reactor with NGR upto 5 meters distance
25
-
-
... More
DISMANTLING OF 50MVAR REACTOR OF REWA ROAD BAY AT 400KV S/S PANKI END
-
-
-
... More
Complete dismantling the accessories of 50 MVAR reactor with NGR after removal of jumpers ,removal of earthing,and opening of cable, and cable connections,dismantling of all radiators, conservator tank,oil pipe lines, all bushing, turrets, marshalling box etc with proper gaskets along with nuts and bolts to complete the job satisfactory including proper stacking, blanking plates with nuts and bolts provided by UPPTCL, gasket all other T&P,manpower shall be arranged by the contractor at his own cost at 400 KV S/S Panki Kanpur end.
1
-
-
... More
Proper dismantling of all water & air pipe lines of emulsifire system of 50 MVAr reactor and its safe shifting to required place.
1
-
-
... More
Complete Drain out (Approx 45KL) of the Reactor oil from 50mvar Reactor with NGR into 209 Ltr empty OIL drum.
1
-
-
... More
Shifting of 63 MVAr main tank with NGR from plingth to required place up to 20 meter distance including turning of tank if required.
1
-
-
... More
Additional shifting of main tank of 50 MVAr reactor with NGR to safe distance 5 meters or part thereof as required.
25
-
-
... More
Refilling of Reactor oil in 50 MVAr Reactor and its NGR upto top cover from 209 Ltr oil drum/tanker by the help of centrifuging machine after shifting of reactor at desired place.
1
-
-
... More
Shifting of all accessories of 50 MVAr reactor with NGR and proper stacking in stores of various accessories like bushing, reactor oil, fans, motor, conservator tank, radiators, marshalling box etc.by crane/hydra/man power etc.with all associated works to complete the job satisfactory including proper stacking, blanking plates nuts and bolt provided by UPPTCL. Gasket and all other T&P etc. shall be arranged by contractor at his own cost. (Shifting distance approx. 100 mtr. from working place.)
1
-
-
... More
ERECTION OF 63MVAR REACTOR WITH NGR AT 400KV S/S PANKI KANPUR AT REWA ROAD BAY.
-
-
-
... More
Providing and fixing of PRV Relay suitable for 63 Mvar Line Reactor Hitachi Make
1
-
-
... More
Providing of Buchholz Relay suitable of 63 Mvar Line Reactor Hitachi Make.
2
-
-
... More
Providing of Silica gel breather with silica gel size 05 Kg suitable of 63 MVAr Line Reactor Hitachi Make
2
-
-
... More
Replacement of old gasket by new gasket of 63 Mvar Reactor and NGR, Radiators, all bushing and all turrets ,1'' ,3'', and 4'' oil pipe lines, buchholz relay conservator tank pipe lines etc.
1
-
-
... More
Complete erection of 63 MVAr reactor with NGR ,radiators,conservator tank, all bushing and their turrets, connecting all oil pipe lines, buchholz relay, breather, marshalling box with associated pipe lines & erection other equipments etc.to complete the job satisfactory including first filling of oil in tank, attending the oil leakage if any for satisfactory complete work with technical specification.
1
-
-
... More
Complete evacuation of 63 MVAr reactor and NGR and refilling of dry air of dew point -40*C or better in vaccum up to pressure of 25kg/cm2 and then again evacuating the reactor main tank after required time interval (approx 12 to 24 hours) using centrifusing machine. The work shall included connecting pipe of machine as required , measuring dew point values of dry air after every cycle till the required value is achieved.
2
-
-
... More
Creating Vaccuum inside the 63 MVAr reactor man tank upto the standard value and with standing the vaccum machine up to 24hrs
1
-
-
... More
Shifting of 02 Nos 20 KL empty oil tanker from store to errection site (approx 200 meter)
1
-
-
... More
Filling the reactor oil in 20 KL oil tanker from 209 Ltr. Drum including shifting of oil Drums from store to work site and there after shifting the empty drum from work site to store for its proper and safe stacking.
28
-
-
... More
Testing of Oil from CPRI/NABL approved Labs as per direction of Supervising Engineer, the test includes (DGA, PPM & BDV etc.) The job also includes taking oil sample in oil sample glass bottle and arrangement to send sample to CPRI/NABL Lab for testing.
4
-
-
... More
Centrifuging of Reactor oil in oil tanker with centrifuging machine of 63 MVAr Line Reactor & recording all the parameter like BDV, IR, PPM hourly & then its filling in main tank & radiator upto required level & thereafter its centrifuging in main tank after opening all the valves of radiator, conservator tank till the satisfactorily result obtained.
28
-
-
... More
Delta earthing of 63Mvar Reactor consisting of fabrication of Delta set with 3 Nos, 3 meter long, 40 mm dia electrodes. its placing inside the ground and connecting all three electrodes witn 75*10mm MS flats at a depth of 700 mm in the ground and connecting the same with earth mat at two places MS round Bar/MS Flats to be arranged by UPPTCL)
2
-
-
... More
Fresh Earthirg of 63 MVAr Reactor with NGR body from two differents points of neutral bushing of reactor with with 75*10/50*6 mm MS. Flat at a depth of 2200 mm in the ground along with complete earthing of radiator, marshaling Box cubical and other points at two points neutral bushing of reactor including painting by black colour below ground level and green paint above ground level in two coats . (MS Flats to be arranged by UPPTCL)
1
-
-
... More
Interconnection of 63 MVAr reactor with laying of various size of cable including shifting of cable,from store to site and termination with cable gland made of brass, copper lug ,cable tie various size in between turrets ,WTI,OTI, Bucholz relay PRV, marshalling box with proper ferruling as per drawing including of any laying additional cables between reactor and control room DCDB/ACDB/Panel/Relays as per requirement (all type various size cable gland lug,tie, ferruyle,saddle,provided contract at his own cost)
1
-
-
... More
Complete interconnection of CT of 63 MVAr reactors moose conductor, jumper of CT/bushing with help of different types connectors with all associated works satisfactory.
1
-
-
... More
Final testing of 63 MVAr Reactor .The job includes all LV Tests ,Insulation Resistance, SFRA,WRM with Omicron Kit.
1
-
-
... More
Spray painting of 63 MVAr Reactor complete with NGR Tank by one coat of red oxide and two coat of smoke gray colour of standard make Asian/Berger OR Equivalent after remove of dust dirt properly through cotton and emery paper.
1
-
-
... More
Taking all electrical safety clearance including deposition of inspection fee etc. for charging of 63 MVAr line reactor Hitachi Make.
1
-
-
... More
Supply of Moose to Moose PG Clamp (Four Bolted Type)
50
-
-
... More
Re-Modeling of Emulsifire system for 63Mvar Reactor
-
-
-
... More
Laying, Installation, Testing and Commissioning of dismantled/old GI Pipe Lines with elbows, tees, sockets, flanges, Bends, Fire Nozzles of required sizes, QB Detectors assembly of old EMulsifier system for its re-commissioning as per details below.
-
-
-
... More
150 mm dia pipe lines.
12
-
-
... More
80 mm dia pipe lines.
5
-
-
... More
50 mm dia pipe lines.
66
-
-
... More
25 mm dia pipe lines.
170
-
-
... More
Installation of high pressure fire nozzles.
80
-
-
... More
Installation of Q.B. Detector assembly with Quartzoid Bulb.
70
-
-
... More
Providing, Laying, Installation, Testing and Commissioning of GI Pipe Lines with sockets, Flanges, Bends, Fire Nozzles of required sizes, QB detectors assembly as per requirement of remodeled Emulsifier system as per details below.
-
-
-
... More
150 mm dia pipe lines.
10
-
-
... More
80 mm dia pipe lines.
90
-
-
... More
50 mm dia pipe lines.
120
-
-
... More
25 mm dia pipe lines.
60
-
-
... More
Construction of RCC Foundation with Grouting of 04 Nos. Foundation Eye Bolts with Cement, Sand, Stone Ballast Mixture in Ratio of 1:3:6 for Installation & Fixing of 80 mm. dia G.I. Pipe support with Base Plate.
30
-
-
... More
Supply for pressure gauge new emulsifire system.
2
-
-
... More
Supply of pressure switch new emulsifire system.
2
-
-
... More
Supply of "Y" Stainer of 150mm dia of Zalota/Kartar/Sir Make new emulsifire system.
1
-
-
... More
Supply of Gate valve 150NB as per IS specification (IS Code 14846) of Zolota/Kartar/Sir Make for new emulsifire system.
1
-
-
... More
Supply of QB Detectors of 79 degree centigrate new emulsifire system addition to detectors of existing emulsifire.
40
-
-
... More
Supply of HV Nozzel K-18X80* new emulsifire system
35
-
-