Uttar Pradesh Power Transmission Corporation Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Nov 2024
Closing Date23 Dec 2024
Tender Amount₹ 14,05,617.84 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Copper Bond

15

791

11865

... More
Bus Post Clamp for Twin Moose

6

843

5060.46

... More
Double tension fitting suitable for ACSR Moose conductor (Busbar Bolted Type)

54

1023

55257.12

... More
Single Suspension fitting suitable for ACSR moose conductor (Busbar)

24

632

15179.76

... More
Carriage

-

-

-

... More
Carriage of following material from Electricity Febrication Unit, Naini, Prayagraj to 132 KV S/S Sarsol under ETD-I, Aligarh ( ALP-06 set, CCM-08 set, BBL-02 set, CGR-04 set & ABL-18 set, CPM-08 SET) (Total=11.885 MT). All T&P man power & vehicle will be arranged by contractor at his own cost (Distance approximate 600 Km.).

1

45000

45000

... More
Proper safe loading of different structure material by sorting them at Electricity Febrication Unit, Naini, Prayagraj. All T&P man power & vehicle will be arranged by contractor at his own cost. ( ALP-06 set, CCM-08 set, BBL-02 set, CGR-04 set & ABL-18 set, CPM-08 SET) (Total=11.885 MT).

1

5000

5000

... More
Proper safe un-loading of different structure material by sorting them at 132 KV S/S Sarsol Aligarh. All T&P man power & vehicle will be arranged by contractor at his own cost. ( ALP-06 set, CCM-08 set, BBL-02 set, CGR-04 set & ABL-18 set, CPM-08 SET) (Total=11.885 MT).

1

5000

5000

... More
Dismentalling & Erection of Isolators & 132 KV Busbar

-

-

-

... More
Erection of Main and auxiliary structure consisting of columns, beams, peaks, masts etc. and auxiliary structure required for installation of Isolators, C.Ts. P.Ts., L.As. and other equipments. The job consists of shifting of structure parts from store to site of erection, erection of structure as per relevant drawing and practices using flat and spring washer with each bolt .Matching of holes , cutting, matching of members if required shall also be done by the contractor without any extra cost to complete the work satisfactorily. All material, water/ electricity shall be supplied by UPPTCL free of cost but all men, disposable material and T&P required for satisfactorily completion of work shall be arranged by the contractor at his own cost.

12

2100

25200

... More
Erection of following equipments as per Instruction manual of various equipments and technical specifications including shifting of material/equipment from store to erection site including all other associated work to complete the job satisfactorily

-

-

-

... More
33 KV Current transformer (CTs)

3

600

1800

... More
120KV Lightning Arrester

3

900

2700

... More
36KV jack Bus Isolator

18

2000

36000

... More
30KV Lightning Arrester

3

800

2400

... More
Junction Box for 33 KV CT

1

1000

1000

... More
To Check and strengthening of grid for earthing of 30 KV LAs including fabrication of 6 no. 3.00 Mt. long electrodes, their placing 500 mm below ground level, interconnections using 50x6 mm MS flat.

1

3000

3000

... More
To Check and strengthening of grid for earthing of 120 KV including fabrication of 6 no. 3.00 Mt. long electrodes, their placing 500 mm below ground level, interconnections using 75x10 mm MS flat.

1

3000

3000

... More
Interconnection of bay equipments and bus bar including cutting, bending of conductor and jumpering, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specification

-

-

-

... More
33KV Side Transformer - 2xMoose

1

700

700

... More
33KV Side jack bus isolator to jack bus - 1xPanther

18

650

11700

... More
Laying of following sizes of control cable in the cable trench from control relay panel to various equipments/ marshalling boxes/J.B. etc. in switch yard as per cable schedule, its saddling at every 75mm. distance with M.S. saddles of size 25x3mm. size including carriage of cable drums from store to laying site and shifting back to store and all other associated work to complete the job satisfactorily as per technical specification.

-

-

-

... More
2Cx2.5 Sq. mm. Unarmoured

1

3000

3000

... More
4Cx2.5 Sq. mm. Unarmoured

1

3000

3000

... More
6Cx2.5 Sq. mm. Unarmoured

1

3500

3500

... More
10Cx2.5 Sq. mm. Unarmoured

0.5

4000

2000

... More
Supply & fixing of junction box size 280×225×150 mm made of 10SWG sheet duly powder coated painted and fixed with MS flat clamp, nut-bolt with 1 no. 2Amp. MCB single pole, nutral and 08 number terminal block.

15

1320

19800

... More
Taking out the above cable from junction box to light fitting fixed over the pole and gantry with fixing clamp of MS flat with each crossed bracing on structure proper dressing with all other associated work to complete the job as per specification including the cost of all material and labour excluding cable.

200

9

1800

... More
Providing & fixing of new generation energy & enviornment friendly long aluminum outdoor beam Street light with high power 120W LEDs as light source & exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 Volt AC input supply of IS make or CGL/Havells/Philips with 2 year warranty after the date of installation Standard brand etc.

20

5500

110000

... More
Supply & fixing of G.I. pipe bracket made of 40mm dia GI pipe 01 number with one band and total length of 850mm having single arm with required M.S. Clamp and Nuts and bolts suitable for fixing LED street light fitting.

15

1155

17325

... More
Dismentalling of all jumpers of old 40 MVA, 132/33 KV T/F (Kanohar Make) from HV & LV side bushing

1

2750

2750

... More
Complete Dismentalling the accessories of 40 MVA, 132/33 KV (Kanohar Make) capacity transformer after Removal of earthing and opening of cables of cable connection, draining out the transformer oil upto required level in 209 litres capacity oil drums/ tanker. Removal of all radiators, conservator tank, oil pipe lines, all bushing turrets, fan motors , marshalling box, RTCC Panel etc with proper gasket along with nuts and bolts to complete the jobs satisfactorlly including proper stacking, blanking plates, nuts & bolts. Gaskets shall be provided by the department. All other T&P etc shall be provided by the contractor at his own cost.

1

22000

22000

... More
Shifting of main tank of 40 MVA 132/33 KV transformer main tank from plinth upto 20 meter distance including turning of tank, if required including all Men Anmd T&P and all other works required to complete the job satisfactory as per tech specification.

1

22000

22000

... More
Additional Shifting of 40 MVA T/F approx 5 mtrs or part there of including turning if any

6

2200

13200

... More
Centrifuging of complete transformer oil in transformer main tank by connecting centrifuging machine, to be arranged by the contractor alongwith operator and taking the B.D.V ,IR & PPM values of the oil periodically till the required value is achieved as per direction of supervising engineer & Tech Speen. .

24000

2

52800

... More
Shifting of main tank of new 63 MVA 132/33 KV transformer main tank from unloading point to plinth approximately 20 meter distance including turning of tank, if required including all T&P and all other works required to complete the job satisfactory as per tech specification enclosed.

1

33000

33000

... More
Additional Shifting of new 63MVA T/F approx 5 mtrs or part thereof including turning if any

6

2750

16500

... More
Complete Erection of new 63 MVA, 132/33 KV transformer by erection of radiators, conservator tanks, all bushing their turrets connecting oil pipe lines, cooling fans motor drive mechanism of tap changer RTCC Panel, oil pumps and associated oil pipe lines etc to complete the job satisfactorly including first filling of oil and topping up of transformer oil (not circulation) in tank radiator, oil pipe lines, conservator tank etc. and attending the oil leakage if any and all other associated works for satisfactorly completion of work. No crane/T&P shall be provided by the department.

1

49500

49500

... More
If Required carriage of 20 KL Capacity oil storage tank on suitable vehicle from 220 KV Khair to Saorsol and revert back to 132 KV S/S Khair after completion of work

1

15000

15000

... More
Earthing of 63 MVA T/F Neutrals, Body, Marshaling box, Drive mechanism etc. with 75X10/50X6 MS flat (To be provided by department) including, bending, cutting & welding etc.

1

5500

5500

... More
Checking & strengthening of delta earthing consisting of 3 Nos., 3 mtr long electrodes its piercing inside ground & connecting all 3 electrodes with 75x10/50x6 mm M.S. Flat and connecting the same with main earthmat at 2 places (For both T/Fs , HV & LV side both) as required excluding the cost of MS Rod and flat).

2

2750

5500

... More
Charging Approval of new Element i.e. 132 KV Transformer and all other equipment from Electricity Safety Department with deposition of fee and processing charges.The payment shall be made on the basis of invoce received or the rate quoted whichever is lower.

1

28000

28000

... More
Dismentalling & Erection of Isolators & 132 KV Busbar

-

-

-

... More
Dismentalling of 132 KV line isolators with E/S post insulator after opening of nut-bolt opening of jumpers ,disconnection of control cable and shifting of dismantlled isolators to store as per instruction of Engineer/In charge

4

7475

29900

... More
Erection of 132 KV line isolators with 1 E/S of different make as per instruction manual and technical specification with post insulator, operating mechanism box, tie rod , arm and proper alignment for smooth operation. This work also includes painting of E/S MOM box with green color, shifting of new isolator from store to site termination of control cable, jumper connection, earthing (paited with green color) and all associated work for complete the job as per instruction of Engineer/In-charge

4

16950

67800

... More
Dismentalling of 132 KV Main Bus isolators with post insulator after opening of nut-bolt opening of jumpers ,disconnection of control cable and shifting of dismantlled isolators to store as per instruction of Engineer/In charge

7

6950

48650

... More
Erection of 132 KV Main Bus isolators of different make as per instruction manual and technical specification with post insulator, operating mechanism box, tie rod , arm and proper alignment for smooth operation. This work also included painting of E/S MOM box with green color, shifting of new isolator from store to site termination of control cable, jumper connection, earthing (paited with green color) and all associated work for complete the job as per instruction of Engineer/In-charge

7

14975

104825

... More
Dismentalling of 132 KV Transfer Bus isolators post insulator after opening of nut-bolt opening of jumpers ,disconnection of control cable and shifting of dismantlled isolators to store as per instruction of Engineer/In charge

7

6950

48650

... More
Erection of 132 KV Transfer Bus Isolators of different make as per instruction manual and technical specification with post insulator, operating mechanism box, tie rod , arm and proper alignment for smooth operation. This work also included painting of E/S MOM box with green color, shifting of new isolator from store to site termination of control cable, jumper connection, earthing (paited with green color) and all associated work for complete the job as per instruction of Engineer/In-charge

7

15975

111825

... More
Dismentalling of 132 KV post insulator after opening of nut-bolt opening of jumpers and shifting of dismantlled PI to store as per instruction of Engineer/In charge

7

795

5565

... More
Erection of 132 KV post insulator, included shifting of new Post insulator from store to site jumper connection, as per instruction of Engineer/In-charge

7

1190

8330

... More
Dismentalling of 132 KV Main Bus from tension/Gun fitting and safely lowering down the single moose conductor having length of approximate-(36x6+24x3) Meter from both of the gantries. Shifting of material form site to store and all other associated .

9

5195

46755

... More
Stringing of 132 KV Main Busbar with Twin ACSR Moose single phase Conductor having Approximate (36x6+24x3) meter between 2 Gantries with spacer and also shifting of material from to stor/site and all other associated work to complete the work satisfactorily as per technical specification

9

13595

122355

... More
Dismentalling of 132 KV Transfer Bus from tension/Gun fitting and safely lowering down the single moose conductor having length of approximate-(36x6+24x3) Meter from both of the gantries. Shifting of material form site to store and all other associated .

9

5195

46755

... More
Stringing of 132 KV Transfer Busbar with Single ACSR Moose single phase Conductor having Approximate (36x6+24x3) meter between 2 Gantries with spacer and also shifting of material from to store/site and all other associated work to complete the work satisfactorily as per technical specification

9

13595

122355

... More
Dismentalling of all 132 KV Bus PTs/CTs/Isolators/CBs jumpers

144

330

47520

... More
Re Jumpering of all 132 KV Bus PTs/CTs/Isolators/CBs jumpers

144

445

64080

... More
Note-

-

-

-

... More
1.GST shall be paid at the rate applicable at the time of invoice.

-

-

-

... More
2.Bidders have to submit their % Rates above or below the Estimated Rates (Excluding "%" symbol in "Blue Box" only).

-

-

-

... More
3.Bidders will submit their Rates by putting "X" for "X"% of Higher than Estimated Rates (ie.will put simply 1 for quoting 1.0% higher than Estimated Rates)

-

-

-

... More
4.Bidders will submit their Rates by putting "-X" for "-X"% of Lower than Estimated Rates (ie.will put simply -1 for quoting 1.0% lower than Estimated Rates)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.