Uttar Pradesh Power Transmission Corporation Limited Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date31 Aug 2024
Closing Date26 Sep 2024
Tender Amount₹ 20,49,227
Costs
EMD
₹ 20,000Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UPTCL_950846_1Bid Award Id
ViewTender No
ETC-23/2024-25Tender Authority
Uttar Pradesh Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://https://upenergy.in/upptcl
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Jumpering of equipments of 40MVA Transformer bay (LV and HV side) with the help pf ACSR panther conductor or ACSR Mosse conductor as required after due cutting of conductors of appropriate size to connect the bus bar conductor of main bus & transfer bus with equipements, transformer etc and equipment to equipement with the keep of suitable clamps/ connectors including, cutting bending shaping etc of the conductor as per site requirement.
1
9999
9999
... More
Centrifuging of the transformer oil filled in oil tanker un-interrupeted till the desired BDV value of the oil is achieved filing of centrifuged transformer oil into tank and radiators,of the above 40 MVA Transformer from the oil tanker then centrifuging & circulation of the tranformer oil in transformer with the help of centrifuging machine un-interrupted till the desired BDV in values of the transfomer oil and IR values are achieved including recording of the puraers such as tempreature vacuum insulation resistance BDV etc even 2 Hrs.
20000
40000
2
... More
Making of delta for neutral earthing by fabrication of 3 nos 3 meter long electrodes of 36/40 mm ida M.S round bar its piercing under the ground at equal diatance of 1 meter at 700 mm depth by digging of earth and connecting all the 03 no electrodes with 75mmx10mm size M.S Flate and taking out the M.S Riser by cutting. bending welding etc, of the M.S Flate (1 Job per detla) (If required)
2
17998
8999
... More
Laying and Termination of control cable as laid as per cable schedule including making necessary holes in glands places of box wherever required/RTCC Panel/Control Panel/transformer etc , providing ferrules and nos for each core (the rate of termination of control cable including all cores of cable at one end with lugs) in switch yard as per cable schedule, its saddling at every 75mm. distance with M.S. saddles of size 25x3mm. size including carriage of cable drums from store to laying site and shifting back to store and all other associated work to complete the job satisfactorily as per technical specification.
-
-
-
... More
2C X 2.5 sqmm
0.5
2500
5000
... More
4C X 2.5 sqmm
1.5
7500
5000
... More
6C X 2.5 sqmm
0.5
2500
5000
... More
10C X 2.5 sqmm
0.5
2500
5000
... More
Termination of following sizes laid control cables extending D.C Supply from DCDB and A.C supply from ACDB to TBC panel & equipments (like CB etc) including drilling of holes, providing & fixing of cable glands, ferrules & crimping type lugs. Including shifting of cables in drums form storage place at the sub station to erection site and shifting back the balance cables to stores at the sub station.
-
-
-
... More
2C X 2.5 sqmm
35
770
22
... More
4C X 2.5 sqmm
100
2200
22
... More
6C X 2.5 sqmm
40
880
22
... More
Providing and fixing 120Watt LED of new generation energy saving & environment friendly long life versatile pressure die-cost aluminium outdoor high beam flood source & exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 V AC supply of IS make of CGL/Havells/Phillips/Bajaj etc. brand
30
231000
7700
... More
Providing and fixing of junction box of 16 SWG MS sheet duly painted size 150*150*200 mm for above light on the bottom of main structure with the help of clamps, junction fix contains 01 no. 05 Amp single pole MCB ( L&T, Havells, Siemens make ) with 01 no. link as per technical specifications
20
22000
1100
... More
Providing and fixing of name plates for various equipments make of 2 mm thick aluminium sheet with covering of 03 mm retro reflective sheet with various size .
-
-
-
... More
a) 600*300 mm
10
8250
825
... More
Repairing of cooling fan of 40MVA T/F. Work including winding of motor replace of bearing and other associated work.
4
22000
5500
... More
Painting of M.S flat with one coat of red oxide and then two coat of green enameled good quality paint as per site requirement. (Paint will be provided by contractor)
684
15732
23
... More
Erection of following equipments including their shifting from storage place at the sub station to erection site and fixing of associated materials like clamps connectors, fittings etc.
-
-
-
... More
Lattice type main and auxiliary structure
3.5
12320
3520
... More
33 KV Tripple feeder control & relay panel.
1
2200
2200
... More
36 KV VCB
2
17600
8800
... More
36 KV CT
6
9900
1650
... More
36 KV bus isolator.
4
17600
4400
... More
36 KV CT junction box
2
440
220
... More
RTCC Panel
1
10000
10000
... More
Spray painting of 40 MVA power Transformer at 220 KV Substation Atrauli Aligarh with 01 coat of red oxide primer and 02 coats of standrad make light grey 608-04 Synthetic enamel paint of first quality after cleaning of rust/dust and oily surface including cost of all material labour and T&P as per technical specification.
1
29800
29800
... More
Replacement of Gasket of all the HV/LV/Neutral bushing, piping, main holes, rediator excluding top cover and OLTC cover all the of 40 MVA transformer including cost of gasket of appropriate size 6/8/10 mm arrangement of men, meterial and T&P will be done by contractor.
1
24300
24300
... More
Dismentaling of Old 05 MVA & 10 MVA transformer electo machenical control and relay panel after opening of cable termination properly and safly and shifting it to disignation place safely as per direction of supervising engineer .
1
7920
7920
... More
Proper cable termination work of RTCC panel/cooling fan etc. after making cable schedule ferruling properly, ferrules will be provide by the contractor only at his own cost.
1
4950
4950
... More
Providing & fixing of 02 ton window AC with all accessories and stablizer (not less than 05 KVA Capacity).
4
169882
42470.59
... More
Providing and fixing of contactor, relay and its wiring circuit for controlling of Transformer cooling fan on existing marshaling box. Cooling fan control circuit designed for auto/manual operation. The following items are to be fixed in the existing marshaling Box i.e. 3 phase, 415 Volt, 20 Amp. contactor and block unit with OLR, Siemens of C&S etc. of any other equivalent make, 10 Amp, Kitkat, HRC fuse unit with 20 amp AC 3 way auto/manual selector Swich etc. of standard make in the existing marshaling box. The wiring should be of 2.5mm PVC copper wire with colour coding, lugs & ferrrules etc. All skilled labour, tools, special T&P, electric welding machine & material shall be provided by the contractor at his own cost.
12
89040
7420
... More
Transportation, Loading, Unloading T&P, Testing & Commissioning
-
-
-
... More
Loading of 40MVA T/F tank including all accesssories on trailor/trucks at Dankaur S/s. The job include jacking the transformer tank for placing the wooden sleepers under the tank and simultaneously lifting the tank by jacking and placing sleepers continusaly under the tank till the wooden plateform comes in the alignment of trailor bed and then shifting the tank from wooden plateform to trailor bed. removal of rails etc from the under the tank proper tightening of tank on trailor bed with the help of wire rope and heavy turn buckle for safe trasportation.
1
34000
34000
... More
Unloading the 40MVA T/F tank including all accessories form trailor/trucks and there proper stacking at the desiganated at 220 KV S/s Atrauli. The job includes opening of laces, jacking the transformer tank from placing the rails, under the tank, shifting it to wooden sleepers plateform to be prepared adjacent to the trailor, removing the rails from under the tank on wooden plateform of sleepers lowering the tank towards grounds by slowly removing the sleepers from under the tank.
1
29000
29000
... More
Safe carriage of 132/33 KV, 40MVA Transformer from 132 KV S/S Dankaur to 220 KV S/S Atrauli. (Distance Aprox-135KM). The insurance shall be got done by contractor at his own cast, as per direction of supervisining engineer.
1
155770
155770
... More
Transformer oil sample collection, testing of transformer oil at CPRI/ERDA/Other lab Noida/Bhiwadi & finishing test report for :-
a- Dissolve Gas Analysis test-01 Nos.
b- Breakedown Voltage Test-01 Nos.
c- Water content.
1
20000
20000
... More
Electrical safety processing fee needed for providing all relevant safety clearance documents from electrical safety deparment for energization of the above commissioned 40MVA transformer and its associated bays (amount in approximation)(Note : the amount payable is actual rate of challan or quoted rate, whichever is lower)
1
27500
27500
... More
Testing of following tests with associated work by NABL approved company/firm on Transformer at the substation from where transformer is to be dispatched with reputed and callibrated testing equipments and providing results in standard format.
-
-
-
... More
Tan delta and capacitence mesuement of Bushing. Tan delta and capacitence mesuement of winding.
1
20000
20000
... More
Sweep frequency Response Analysis (SFRA)
2
10000
5000
... More
Truns ratio measurment on all taps.
1
5000
5000
... More
Winding resistance measurement at all taps.
1
5000
5000
... More
Insulation resistance including polarisation index
Insulation resistance test on core-frame
1
7000
7000
... More
Short circuit test on low voltage on three taps
1
6500
6500
... More
Magnetising current test on low voltage on three taps
1
6500
6500
... More
Magantic balance on low voltage
1
6500
6500
... More
Vector group test
1
6500
6500
... More
Shifting of main tank of the 40 MVA transformer to its plinth from place of unloading point (Up to 20 Mtr.) including turning of the tank as required.
1
25000
25000
... More
Additional Shifting of main tank of the above 40 MVA transformer upto Approx 80 Meter Distance ( 1Job For every 5 meter or part)
16
8000
500
... More
Supply component :
-
-
-
... More
Supply of 40mm dia MS rod for main earth mat.
95
54482
573.5
... More
Supply of 415V AC Lighting Distribution Board ( ACDB )
2
187489
93744.54
... More
Supply of Fire Extinguisher CO2 Cylinder 9 Kg
4
52152
13038
... More
Supply of Fire Extinguisher CO2 Cylinder 22.5 Kg
2
46137
23068.5
... More
Supply of Fire Bucket capacity 9 ltr galvanised mild steel
50
26375
527.5
... More
Supply of PG Clamp duly made of LM-6 Aluminium alloy, suitable for ACSR Panther to Panther conductor complete with 3 No. 16x75mm sizw GL Bolts, nuts, Spring & Plain Washer as per sample.
21
9685
461.23
... More
Supply of PG Clamp duly made of LM-6 Aluminium alloy, suitable for ACSR Moose to Moose conductor complete with 3 No. 16x75mm sizw GL Bolts, nuts, Spring & Plain Washer as per sample.
24
14330
597.1
... More
Copper bond
50
34100
682
... More
Bus post clamp suitable for twin moose.
18
15181
843.41
... More
Bus post clamp suitable for panther.
18
8377
465.42
... More
Supply of 132 KV Isolator terminal connector duly made of LM-6 Aluminium Allow, Suitable for ACSR twin panther conductor 60x75mm size GI bolt and nuts and washer as per sample
30
45000
1500
... More
Supply of 10A 1 pole with 1PP 240/415V AC MCB
20
3017
150.88
... More
Supply of 63A 4 Pole with 3PP 415 Volt MCB
20
26240
1312
... More
Supply of 32A 4 Pole with 3PP 415 Volt MCB
30
11394
379.8
... More
Supply of 16A 1 Pole with 1PP 240 Volt MCB
25
1619
64.78
... More
Note-
-
-
-
... More
1.Bidders have to submit their % Rates above or below the Estimated Rates (Excluding "%" symbol in "Blue Box" only).
-
-
-
... More
2.Bidders will submit their Rates by putting "X" for "X"% of Higher than Estimated Rates (ie.will put simply 1 for quoting 1.0% higher than Estimated Rates)
-
-
-
... More
3.Bidders will submit their Rates by putting "-X" for "-X"% of Lower than Estimated Rates (ie.will put simply -1 for quoting 1.0% lower than Estimated Rates)
-
-
-
Evaluation Notes How It Works ?