Uttar Pradesh Housing And Development Board Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Housing And Development Board - UPAVP Tender

Works
Electrical and Electronics
Eprocure
Opening Date19 Mar 2024
Closing Date10 Jun 2024
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing, erecting, testing & commissioning approved make oil immersed naturally ONAN cooled, double wound, core type outdoor copper wound 11 kV/ 433 Volts Step Down Transformer of following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed and Off Load Tap Changer continuously rated for a full temperature rise in oil not exceeding 40 deg. C at maximum ambient temp. Of 50 deg. C complete with necessary radiator first filling of new transformer oil & standard fitting as below complying with I.S. 1180 LEVEL 2 standards OFF load tap changing range steps -10% to 5% on H.V in steps of 2.50% .and L.V. for variation should be provided The H.V. shall be connected delta & secondary with star connection. The transformer should have cable-end boxes on H.T. side & on L.T. side suitable for cables and outdoor type end termination as per requirement complete with test certificates from manufacturers. Losses As per IS 1180 LEVEL-2.

-

-

-

... More
Conservator with plain oil level gauge and oil drain plug 1nos., Top filter valve 1 Nos., Bottom filter-Cum-drain valve 1Nos.., Rating and diagram plate 1nos., Earthing Terminals 2Nos., ThermoM pockets 1Nos., Lifting Lugs 2/4 Nos., Air release plug 2/4 Nos., Bi-directional rollers 4Nos., Jacking pads 1Nos., Pressure release valve 1Nos., Separate Bare LV neutral 433V , Detachable/Fixed type radiators 1Nos., Magnet Oil level gauge, Oil temperature indicator 1Nos., Winding temperature indicator 1Nos., Marshaling Box single window 1No., Double flot buchholz's relay with alarm and trip contact. Copper Wound 250KVA 11/0.433KV Make : Siemens/ Kirloskar/Schmeider/Voltamp/Areva

1

765000

765000

... More
Design, Manufacturing, Supply, Commissioning & Testing of Main LT Panel. The panel will be totally enclosed type with, free standing, floor mounted, indoor duty, dust & vermin proof, , front operated, electrical panel fabricated from 2 mm thick M.S. Sheet as per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multiM, indication lamps, CT's, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness. The Main LT Panel shall use all breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. All having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification. No. incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases over 250A & thermal magnetic release below 250A. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA. INCOMMER : 500Amp. 25KA FP With S/C, U/V, E/F Protection MCCB 2no. (From Transformer) BUSCOUPLER : 500Amp. 25KA FP With S/C, U/V, E/F Protection MCCB 1no. (From Transformer)BUSBARS : 2 Nos. 630 Amp FP busbars of aluminium alloy as per SLD. OUTGOING : 200Amp. 25KA TP MCCB 2 No. (APFC Panel) OUTGOING : 250Amp. 25KA FP MCCB 4 No. (TATA+Conference Hall+Girls Hostel+Spare)OUTGOING : 63Amp. 16KA FP MCCB 5 No. (Ex. Light+Pl+Spare) INSTRUMENTS : 1 sets of multifunction M with paraM current,voltage,KWH,KVAH,Power factor on incoming from transformers.1 Sets of phase indicating lights (RYB) with protection fuses (one set for No. incoming breaker).1 Sets breaker 'ON' & 'OFF' indicating lamp (one set for No. incoming breaker).2 Sets auto trip indicating lamp . Make : L&T/ABB/Schneider/Siemens

1

595200

595200

... More
100KVAR CAPACITOR PANEL INCOMING : 1 Nos. 200 Amp TP MCCB 25KA BUSBARS : 1 Nos. 250 Amp TPN busbars of aluminium alloy as per SLD. OUTGOING 12 stepped Automatic Power Factor Correction relay (APFC relay).,,4 Nos. 32 Amp TP MCB. 4 Nos. 25 Amp TP MCB.,4 Nos. capacitor duty contactor (one for No. 15KVAR capacitor unit)., 4 Nos. capacitor duty contactor (one for No. 10KVAR capacitor unit).,4 Nos. 15 KVAR super heavy duty mix dielectric low loss Capacitor suitable for non leniar loads upto 20% ,4 Nos. 10 KVAR super heavy duty mix dielectric low loss Capacitor suitable for non leniar loads upto 20% , 8 sets of push button stations Red and Green for manual operation of capacitor units with auto/manual selector switches., 1 No. Indicating lamp for No. capacitor unit to indicate that the unit is 'ON'., 1 No. Toggle switch for changing automatic to manual operation of capacitor units., Power factor M., 1 No. 0 to 200 Amp amM with selector switch & C.T's., 1 No. 0 to 500 Volts voltM with selector switch. Make : L&T/ABB/ Schneider/ Siemens

1

215000

215000

... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Make : KEI/Polycab/Havells/Gloster

-

-

-

... More
3.5 core 150 Sqmm Cable

100

95700

957

... More
3.5 core 300 Sqmm Cable

615

991995

1613

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Make : Dowells/Gripwell/Camel/Hex

-

-

-

... More
3.5 core 150 Sqmm Cable

4

2248

562

... More
3.5 core 300 Sqmm Cable

12

11832

986

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

24652

6163

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

22828

11414

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

100

20100

201

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

100

11900

119

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

80

64160

802

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 300mm Dia

10

9400

940

... More
S/F of cable root marker

2

900

450

... More
Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work.

2

610

305

... More
Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules.

1

85

85

... More
Supply and fixing of 2 metres high cage fabricated with 3mm thick expanded metal fixed on 50mm x 50mm x 6mm angle iron frame having vertical members spaced at 1 to 1.25 mts and horizontal members spaced at 1 mt. The vertical members shall be grouted in floor and horizontal members in the wall to a depth of 300mm with ends forked. The cage shall have 2000mm x 1000mm size one leaf door with locking device having door frame fabricated with 35mm x 35mm x 6mm angle iron and 3mm expanded metal duly fixed with the cage member with hinges etc. The cage shall be painted with red oxide primer and synthetic enamel paint. The job includes all materials, labour, T&P etc. for proper completion of work.

40

51000

1275

... More
11KV Pole mounted CT/PT CTR 10/5

1

29693

29693

... More
3PH 4W Static TVM 11KV

1

3768

3768



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.