Uttar Pradesh Housing And Development Board Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Housing And Development Board - UPAVP Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date28 Jan 2023
Closing Date8 Feb 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8km from the site of work and including watering dressing etc. Rate to include cost of all materials, labour and T&P etc. required for proper completion of the work.

74.37

-

650

... More
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm.

579.86

-

190

... More
R.C.C. work with cement approved coarse sand (FM 2.20 to 3.60) and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.

5.62

-

8610

... More
R.C.C. work with cement approved coarse sand (FM 2.20 to 3.60) and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in sunshade/slab excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire.

103.67

-

8627

... More
R.C.C. work with cement approved coarse sand (FM 2.20 to 3.60) and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lighter beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire.

75.26

-

9319

... More
R.C.C. work with cement approved coarse sand (FM 2.20 to 3.60) and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in Footing excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire.

100.85

-

6500

... More
R.C.C. work with cement approved coarse sand (FM 2.20 to 3.60) and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in Column excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire.

48.36

-

9600

... More
Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in over all rates ) wrought to required shape as necessary including bending, and also including supply of steel and wastages and overlapping and hooks required for completion of the work.

526.36

-

9298

... More
Class 150 brick work in 1:6 cement and coarse sand (FM 1.50 to 2.20) mortar in foundation and plinth including supply of all materials, labour and tools and plants etc. required for proper completion of the work.

131.43

-

5060

... More
M-150 brick work in 1:6 (one cement and six coarse sand of 1.50 to 2.20 fineness modulus) in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required proper completion of the work.

261.92

-

5540

... More
M-150 brick work in 1:4 (one cement and four coarse sand of 1.50 to 2.20 fineness modulus) in superstructure for wall thickness 12 cms & below brick work.

53.82

-

5880

... More
Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : 12 mm thick one side Pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade -1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT-1 conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823, Grade -1,

36.54

-

2549.24

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

98.28

-

2562.56

... More
Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws 35 mm thick shutters With ISI marked stainless steel butt hinges of required size Second class teak wood

51.45

-

3846.05

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).

5.05

-

109255.96

... More
Mild steel or iron work of small sizes and sections and such as holding down bolts, hold fasts, tie rods ,gratings etc. ( when not included in an over all rates ) wrought to required form, including supply of steel, bolts, nuts and wastages etc. and their fixing required for completion of the work. Fabrication of grill/stairs case railing

3126.6

-

97.36

... More
Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).

111.82

-

7479

... More
Fixing of steel or wooden chaukhats in position. (a) Door chaukhats

140.49

-

110

... More
Fixing of steel or wooden chaukhats in position. (b) Window chaukhats

45.35

-

85

... More
Fixing of steel or wooden chaukhats in position. (c) Ventilator chaukhats

6.48

-

60

... More
15mm thick plaster with cement mortar in consisting of 1:4 cement and approved coarse sand (FM 1.50 to 2.20) of minimum thickness not be less than 10mm including supply of all materials, labour T&P etc. required for proper completion of the work. ( plinth plaster)

90.8

-

188

... More
12mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand (FM 1.50 to 2.20) of minimum thickness not be less than 10mm including supply of all materials, labour T&P etc. required for proper completion of the work. ( plinth plaster)

1737.29

-

126

... More
15mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand (FM 1.50 to 2.20) of minimum thickness not be less than 10mm including supply of all materials, labour T&P etc. required for proper completion of the work. ( plinth plaster)

1680.97

-

163

... More
Providing and laying rectified glazed ceremic floor tiles 300x300 mm or more size (thickness to specified by approved make & colors) of first quality confirming to IS 15622 of approved make in colors & shade laid on 20mm thick cement mortar 1:4 (Icement 4 coarse sand) including grouthing the joints with white cement and matching pigments. (flooring)

575.77

-

1243

... More
Providing and laying vitrified floor tiles Kajaria KERRO Brand or Equivalent brand of super quality in different size (thickness specified by manufacture) with water absorption less than 0-8% and confirming to IS 15622 of approved make in colors & shade laid on 20mm thick cement mortar 1:4 (I cement 4 coarse sand) including grouthing the joints with white cement and matching pigments etc complete. ( Size of tiles 600x600mm). (Anti Skid Vitrified flooring)

717.77

-

1283

... More
25mm thick Kota stone slab flooring over 20 mm (average) thick 1:4 cement & coarse sand base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete with base of cement mortar.

99.46

-

1512

... More
25mm thick Kota stone slab in riser of steps, skirting 1:3 ( I cement 3 coarse sand) and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete.

9.54

-

1310

... More
25mm thick 1:2:4 cement concrete floor with cement approved coarse sand and 2 cm graded approved stone grit laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified over and excluding stone ballast 4cm guage in the proportion of 1:4:8 and removing any overlapping mortar at the joints of panels if any giving them a uniform finish including supply of all materials labour T & P etc required for proper completion of the work.

202.39

-

345

... More
Painting or varnising on iron work in small areas on new wood work with two coat of ready mixed priming paint and one coat of approved superior quility ready mixed paint of clear synthetic varnish including supply of all materials, labour and T & P etc. required for proper completion of the work.

283.65

-

118

... More
Melamine polishing on wood work (one or more coat).

241.62

-

98.27

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicon additives of required shade New work (Two or more coats applied @1.43Ltr/10sqm over including basecoat of water proofing cement paint applied @ 2.20 kg./10 sqm)

1813.13

-

100

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification.Two or more coats on new work

1405.23

-

77.02

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete

3156.22

-

102.84

... More
Providing and fixing glass strips of 3.15 mm(1/8") thickness in joints of floors & skirtings at the time of laying floors flush with leavel, including labour and T & P etc complete. (25 mm depth)

207.68

-

23

... More
Providing & fixing Stainless steel Sliding bolts with nuts & bolts (Bolt 16mm dia 250mm long)

71

-

380

... More
Providing & fixing Stainless steel Tower bolts with nuts & bolts (Bolt 10mm dia 200mm long)

91

-

162

... More
Providing & fixing Stainless steel handles with screws etc. complete (a) 150 mm

142

-

45

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin- Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

579.86

-

1264.59

... More
Making grooves 10 to 12 mm wide and x 8mm deep in plaster of the wall or in ceiling vertically or horizontally as required.

1574.26

-

31

... More
Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete. 20 mm dia

90.4

-

311.59

... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and lerestory windows using wire gauge with average width of perture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 2nd class teak wood beading 62X19 mm

104.22

-

967.28

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab over 0.50 sqm

21.78

-

3674.62

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 5.50 mm thick glass panes

100.54

-

750

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.

25.56

-

428.96

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent.

69.93

-

3245.7

... More
Wall painting (two coats) with plastic emulsion paint of second quality approved brand and manufacture on undecorated wall surface to give an even shade in cluding thoroughly brushing the surface free from mortar droppings and other foreign matter and sand prepared smooth.

938.67

-

70

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

194.4

-

508.38

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

10.2

-

3970.07

... More
P & L of factory made 80mm thick rubber moulded interlocking cement concrete tiles 30mpa including 25mm thick compacted bed of fine sand compacting & proper embedding/laying of interlocking tiles levelling & dressing of surface to required level & slope filling joints with fine sand including the cost of material labour T & P etc required for proper completion of work.

301.12

-

980

... More
Laying CC road slab consisting of 1:1.5:3 cement,coarse sand & approved 2cm guage stone grit over prepared sub grade after its rectification & bringing it to proper camber & including supply of all material labour T & P etc required for proper completion of work finished to required templete as directed by E/I but excluding cost of metal required for reflection of the sub grade.

48.06

-

8800

... More
Water Supply & Sanitory work Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

10

-

3175

... More
Providing and fixing white vitreous china pedestal type water closet ( European type W.C. pan ) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid.

8

-

3175

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap.

20

-

1585

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board of size 510x1040x200mm

8

-

5715

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Felxible pipe. 32mm dia

18

-

70

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Felxible pipe. 40mm dia

8

-

80

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

16

-

1035

... More
Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore

6

-

248.57

... More
Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms.

16

-

498.51

... More
Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms

6

-

121.48

... More
Providing and fixing of UPVC SWR pipe of class B of ISI mark Confirming to IS code 13592 (make prince, supreme finolex) in internal works of toilet and RWP etc. including fixing with rubber rings etc. including cost of all material, labour etc. complete. 110mm diameter

510

-

432

... More
Same as above item but for 160mm diameter

100

-

745

... More
Haunching of SWR pipe 90mm or 110mm with pcc 1:2:4 cement concrete ( 1 cement:2 coarse sand:4 stone grit) AR

550

-

504

... More
Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali.

50

-

870

... More
Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 75/90 mm

6

-

65

... More
Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 110 mm

6

-

72

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 20mm dia nominal outer dia pipes

180

-

160

... More
Same as above item but for 25mm dia nominal outer dia pipes

135

-

200

... More
Same as above item but for 32mm dia nominal outer dia pipes

110

-

255

... More
Same as above item but for 40mm dia nominal outer dia pipes

60

-

355

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 16mm dia nominal outer dia pipes

175

-

230

... More
Same as above item but for 20mm dia nominal outer dia pipes

135

-

260

... More
Same as above item but for 32mm dia nominal outer dia pipes

100

-

380

... More
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 45 cm length 15mm nominal bore

10

-

75

... More
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 . 15mm nominal bore

24

-

370

... More
Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore

16

-

470

... More
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore

48

-

450

... More
Providing and fixing gun metal gate valve with wheel of approved quality(screwed end). 25mm dia nominal bore

16

-

390

... More
Same as above item but for 32mm dia nominal bore

6

-

470

... More
Same as above item but for 40mm dia nominal bore

4

-

575

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 25 mm nominal bore

6

-

440

... More
Supply and hoisting of Sintex or equivalent high density polyethylene seemless of piece moulded tanks and placing the same in proper position including all taxes, labour and T&P etc. for proper completion of work. Tnak should be ISI marked, Sintex or equivalent.

10000

-

10

... More
Providing and fixing gun metal gate valve with wheel of approved quality. 20 mm dia nominal bore

16

-

360

... More
Providing and fixing UPVC S.W.R Gully trap grade 'A' complete with C.I. grating brick masonry chamber and water tight C.I.cover frame of 300 x 300mm. size (inside) square mouth traps of "P" or "S" type traps. 100 x 150 mm. dia.

8

-

1660

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 900x800mm and 500mm deep including CI cover with frame With FPS bricks of class designation 150

25

-

9100

... More
Extra for depth of man hole size 900x800mm

6

-

5000

... More
Electrification Work Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, piano type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. Add for light for point with modular type switch in place of piono type switch.

130

-

654

... More
Wiring point for two ways light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash. Add for two way points with modular type switch in place of piono type switch.

3

-

956

... More
Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. Add for Fan/Exhaust Fan points with modular type switch in place of piono type switch.

66

-

715

... More
Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire and piano type switches & socket etc., complete in all respects as directed, including matching color wash. Add for plug points with modular type switch in place of piono type switch.

78

-

410

... More
Wiring points for Call bell with 1.5 sqmm.FRLSH PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq. mm. FR PVC insulated multistrand copper earth contunity wire and piano type bell push or 2pin socket etc.complete in all respects.as directed including matching colour wash. Add for call bell points with modular type switch in place of piono type switch.

7

-

652

... More
Wiring point for light duty exhaust fan & power plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash. Add for HPSV/Exhaust Fan points with modular type switch in place of piono type switch.

24

-

940

... More
Supply & wiring of submains with two number 2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect

950

-

121

... More
Supply & wiring of submains with two number 4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect.

675

-

149

... More
Supply and wiring of submain with 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 32 mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects.

250

-

505

... More
Supply & fixing of single wall bracket on matching M.D.F.E.G. board base etc. complete in all required.

68

-

1650

... More
Supply & fixing ofrecess/Surface/Pendent mounting round 6 to 8 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. Excluding lamp/bulb

1

-

1350

... More
Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete, excluding tube on surface complete in all respect. 1 X 22 W

58

-

1190

... More
Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.

4

-

5380

... More
Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects.

300

-

210

... More
Supply, fixing of 6 Amp to 32 Amp SPMCB (10KA) C Curve (6

20

-

260

... More
Supply and fixing of surface/ flush mounting Distribution board with (Legrand Lexic) without MCB complete in all respect, as directed at site by Engineer Incharge. 4 Way TPN (CAT-A)

12

-

3610

... More
Supply and fixing of surface/ flush mounting Distribution board with additional metal door without MCB complete in all respect, 12 way SPN Cat- A

18

-

2250

... More
Supply and fixing Single Pole MCBS Blanking Plate complete in all respects.

23

-

15

... More
Supply & fixing of Call Bell Of Approved Make on matching polished MDFEG board brass including connection etc. as required.

10

-

175

... More
Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all materials, labour, T & P etc. complete.

54

-

625

... More
Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.

38

-

140

... More
Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.

28

-

195

... More
Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properly etc. complete as required.

28

-

810

... More
S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.

38

-

150

... More
Supply fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.

38

-

267

... More
Supply & erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan with standard down rod, blades including connection etc. complete as required-Make: Usha Cat No.SONATA MAX

32

-

1800

... More
Supply & erection of 200 mm pvc havells VENTIL AIR DX 200 MM 5 BLADE EXHAUST FAN

14

-

1650

... More
External Electrical work Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm 4.0 core

50

-

343

... More
Same as above item but for 6 sqmm 4.0 core

360

-

297

... More
Supply and fixing of brass nickle plated compression gland for PVC insulated and armoured served sheathed, under ground cable including rubber ring etc. complete in all respects, the armouring of the cable shall be properly connected with earth as per direction of Engineer-in-charge. 16 sqmm 4.0 core

2

-

87

... More
Same as above item but for 6 sqmm 4.0 core

2

-

80

... More
Supply and fixing of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape, and making connections etc. complete in all respects as per directions of the Engineer-in-charge. 16 sqmm.

8

-

21

... More
Same as above item but for 6 sqmm

48

-

18

... More
Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra)

5

-

10040

... More
Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects.

40

-

90

... More
Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.

12

-

16500

... More
Supply and fixing of LED street light fitting having diecast aluminium body and diffuser/reflector with driver set suitable for 75 watt to 90 Watt confirming to IP 65 protection complete in all respect.CAT AAA

12

-

8850

... More
Supply & wiring of submains with four number 4.0 sqmm & two number 2.5 sq.mm FRLSH PVC insulated copper conductor cable in PVC conduit complete. Including supply of all materials, labour, T&P etc. required for proper completion of the work as directed by E/I.

200

-

201

... More
S/F of 63 Amp 415V heavy duty double break HRC fuse type metal clad TPN complete with HRC fuse etc.on angle iron frame complete in all respects.

1

-

6110

... More
Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN complete in all respect.

1

-

19200

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil 300 mm dia ( Rock strata)

90

-

1176.04

... More
Same as above item but beyond 90 m. boulders

20

-

1296.77

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.150 mm nominal size dia

70

-

555.09

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia

40

-

566.22

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.

3.5

-

1086.94

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

12

-

761.27

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia

1

-

174.99

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp.

1

-

1336.25

... More
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia

1

-

233.95

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore

80

-

485

... More
PUMPING SET KSB make submersible pump set suitable for installation in bore well of min 150 mm inner dia preferably more and having under noted specifications. TYPE UQD 182/10 + 6 UMA I/H 150/22(S/D)+7.5HP Capacity 1400LPH Total Head 92M No of stages 6 Max OD of the pump set 150mm size of discharges out let 3” Speed in RPM 2900 RPM H. P. of Motor 5.5 KW/ 7.5 HP Method of starting star delta supply of voltage 400 V + 3% 3 phase The pumping set shall be comprise ( a ) Built in non-return valve ( b ) Six stages bowl assembly with bronze impellers and S. S. impeller shaft etc. ( c ) 7.5 HP 2900 RPM sub mersible electric motor suitable for Star/Delta starting with 3RM cable 2 x 3 x 4 sq mm

1

-

49302

... More
Supply of control pannel cubical type as per detail specification for 7.50 H.P.

1

-

25000

... More
Errection & commissioning of 7.50 H.P. submersible pump.

1

-

3500

... More
3 Core 4.0 sqmm submersible copper cable

1

-

15000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.