Uttar Pradesh Housing And Development Board Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Uttar Pradesh Housing And Development Board - UPAVP Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Aug 2024
Closing Date28 Aug 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

75.33

373639

4960.03

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

25.99

40190

1546.37

... More
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration

190.81

43077

225.76

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

56.34

371083

6586.5

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

120.06

1005803

8377.51

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

31.79

251216

7902.37

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

108.02

30844

285.54

... More
Suspended floors, roofs, landings, balconies and access platform

425.91

287557

675.16

... More
Shelves (Cast in situ)

103.48

69865

675.16

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

686.62

368165

536.2

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

414.48

290115

699.95

... More
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles

400

892864

2232.16

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.

-

-

-

... More
Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.

-

-

-

... More
Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.

-

-

-

... More
Single pile upto 50 tonne Safe capacity

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity)

2

79761

39880.82

... More
Routine test (Test Load 1.5 times the Safe capacity)

2

28589

14294.96

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

370.5

2909495

7852.89

... More
Brick work with bricks of class 150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

56.82

394078

6935.56

... More
Brick Work with bricks of class - 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 ( 1 cement : 6 coarse sand)

119.48

1001987

8386.24

... More
Brick Work with bricks of class - 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 ( 1 cement : 4 coarse sand)

65.66

582187

8866.7

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:

-

-

-

... More
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (Double leaves)

16.8

30573

1819.85

... More
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (Single leaf)

96.39

167926

1742.16

... More
Mild steel or iron work of small sizes and sections such as holding down bolts,hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel , bolts, nuts and wastages etc their fixing required for completion of the work

-

-

-

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).

1359.21

140243

103.18

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding

223.2

35607

159.53

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

812.7

314157

386.56

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)

580.5

268167

461.96

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)

116.1

99481

856.86

... More
Fixing of steel or wooden chaukhats in position.(a) Door chaukhats

58

9860

170

... More
15 mm cement plaster in single coat on plinth 1 cement: 4 course sand in plinth.

40.54

11670

287.87

... More
12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)

1718.04

429887

250.22

... More
15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand)

1081.15

311230

287.87

... More
Add for plaster groove in plastered surface or moulding to R.C.C. projections.

2207.74

126039

57.09

... More
Making drip course in sun shade or facia as per direction of Engineer incharge including supply of all materials,labour T & P etc for proper completion of the work. Excluding GST

199.7

11400

57.09

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.

56.54

54753

968.41

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

302.26

279055

923.23

... More
Providing and laying vitrified floor tiles in different size (Thickness specified by manufacturer) with water absorption less than 0.8% and confirming to IS 1622 of approved make in all colors and shade laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand ) including grouting the joint with white cement and matching pigments etc. complete ( Size of Tile 600 x 600 mm )

256.17

289756

1131.11

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complet ( Size of Tile 600 x 600 mm )

26.31

31092

1181.79

... More
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Dark shade pigment using ordinary cement

7.2

8041

1116.81

... More
25 mm thick cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of size 20 mm and below) by laid over base concrete finished with floating coat of neat cement (base concrete to be paid separately) including fixing of glass strips.

90.24

17453

193.41

... More
40m thick in cement concrete floor 1:2:4, ( 1 cement : 2 Coarse sand : 4 gredded stone aggregate 20 mm Nominal size) finished with a floating coat of neat cement. including supply of all material , labour T&P etc. required for proper completion of the work and curing complete.

10.72

4794

447.22

... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

11.16

1387

124.29

... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture

226.38

29051

128.33

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

1718.06

214035

124.58

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

3405.67

386952

113.62

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water thinnable priming coat with cement primer

1687.61

228131

135.18

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes

18.27

14162

775.2

... More
Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm

18

9900

550

... More
Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm

46

21160

460

... More
P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 250 mm x 10mm

36

9360

260

... More
P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 250 mm x 10mm

46

11960

260

... More
as above 150x10mm for window

280

42000

150

... More
Providing & fixing stainless steel door handles with screws and 150mm long.SI marked

36

2160

60

... More
Providing & fixing stainless steel door handles with screws and 150mm long.SI marked

46

2760

60

... More
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick

90.24

6028

66.81

... More
25 mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :

162.85

231015

1418.58

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete

16.27

27895

1714.53

... More
Providing and fixing stainless steel (Grade 304) railing made of hallow tubes, chanells, plates etc. including welding grinding buffing, polising and making corvechare (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge.(for payment purpose only weight of stainless steel members shall be considered excluding fixing assessories such as nuts, bolts, fasteners etc.

355.97

200201

562.41

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab upto 0.50 sqm

2.29

9026

3941.74

... More
Providing & laying of 80mm thick mechanically compressed interlocking cement concrete pavers block 12 cm th. C.C. (1:4:8) with cement and coarse sand with40mm gauge stone ballast including 4cm thick fine sand cushion and 3cm th. local sand filling over entire surface of Interlocking and gaps and corner filled with (1:3) cement mortar including cost of all material labour , including levelling & dressing of surface to required level & slope as per the direction of Engineer in charge

21.18

33602

1586.5

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.

-

-

-

... More
(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.

-

-

-

... More
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

169.38

207763

1226.61

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)

84.99

38185

449.29

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design

150.4

33417

222.19

... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size)

51.36

15364

299.15

... More
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

51.36

5465

106.42

... More
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

40

3543

88.58

... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

40

28634

715.86

... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 12 mm mild steel U beading

120.15

82165

683.86

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

2.08

11932

5736.58

... More
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 20 mm dia

16.92

4231

250.11

... More
Providing & filling of cinder in sunken portion of building including breaking into required sizes including supply of material, labour, T&P required for proper completion of works.

6.69

16725

2500

... More
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated hollock wood

7.2

17060

2369.52

... More
Providing and fixing 150 mm S.C.I. tee at the inlet and outlet of septic tank.

2

830

415.03

... More
Providing & fixing 75mm dia vent pipes.

1

863

863.56

... More
Providing & fixing of 75mm dia cast iron terminal guard.

1

294

294.71

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.

-

-

-

... More
M.D. -10- Circular shape 500mm internal diameter

4

3415

853.81

... More
L.D. -2.5- Circular shape 450mm internal diameter

2

1703

851.66

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

39117

19558.98

... More
Providing and laying design mix cement concrete of M-20 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-20 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer

37.93

265685

7004.62

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:

-

-

-

... More
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

10

49275

4927.55

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:

-

-

-

... More
White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps

10

16759

1675.98

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required

-

-

-

... More
Kitchen sink with drain board of size 510x1040x200mm

2

10425

5212.69

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe

-

-

-

... More
a) 32mm dia

10

756

75.65

... More
b) 40mm dia

2

169

84.97

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

10

11708

1170.8

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 100 mm diameter

8

1129

141.22

... More
Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms.

10

5162

516.21

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.

10

1225

122.58

... More
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.

10

7889

788.93

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter

99

27205

274.8

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

8

1737

217.17

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm

47

12706

270.35

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

8

318

39.83

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe

40

28098

702.46

... More
Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work.

-

-

-

... More
75 mm O.D.

101

34340

340

... More
110 mm O.D.

61

27450

450

... More
Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali.

48

43680

910

... More
Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735.

-

-

-

... More
Size 75 mm

22

3300

150

... More
Size 110 mm

14

2870

205

... More
Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735.

-

-

-

... More
Size 75/90 mm

2

120

60

... More
Size 110 mm

6

396

66

... More
Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735.

-

-

-

... More
Size 75x75x75 mm

18

3096

172

... More
Size 110x110x110 mm

18

4770

265

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall

-

-

-

... More
20mm nominal outer dia pipes

16

4678

292.38

... More
32 mm nominal outer dia Pipes

69

26062

377.72

... More
50 mm nominal outer dia Pipes

18

12243

680.18

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.

-

-

-

... More
15 mm nominal outer dia pipes

8

2899

362.46

... More
20 mm nominal outer dia pipes

45

17614

391.44

... More
Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length

-

-

-

... More
15 mm nominal bore

18

1281

71.17

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :

-

-

-

... More
15 mm nominal bore

18

6642

369.02

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.

-

-

-

... More
15 mm nominal bore

2

1163

581.74

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:8931

-

-

-

... More
15 mm nominal bore

50

20908

418.17

... More
Providing & fixing C.P. Brass extension nipple(size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.

46

2505

54.46

... More
Providing and fixing gun metal gate valve with wheel of approved quality.

-

-

-

... More
20 mm dia nominal bore

14

5504

393.15

... More
50 mm dia nominal bore

2

1495

747.54

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :

-

-

-

... More
25 mm nominal bore

3

1013

337.89

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

4500

36045

8.01

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
65 mm nominal dia Pipes

10

12191

1219.18

... More
50 mm nominal dia Pipes

15.08

8721

578.32

... More
Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.

-

-

-

... More
110 mm O.D.

60

27000

450

... More
160 mm O.D.

70

54600

780

... More
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.

-

-

-

... More
100mm diameter S.W. Pipe

60

42000

700

... More
150mm diameter S.W. Pipe

70

62300

890

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 15

6

11945

1990.86

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design :

-

-

-

... More
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 15

-

-

-

... More
(i) For Sewer Line

11

102284

9298.63

... More
Extra for depth of man hole size 90x80 cm

3

19278

6426.05

... More
Constucting brick masonary chamber 600x600x750 mm inside with FPS brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve / air valve , with CI surface box 100mm top diameter,160mm bottom diameter and 180 mm deep (inside) with chainage lid and RCC top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 grade stone aggrgate 20 mm nominal size) , necessary excavation , foundation concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand) 12mm thick finished wuth a floating cost of neat cement complete as per standard design.

2

15818

7909.25

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar

24

9518

396.61

... More
Point wiring in PVC conduit, with piano type switch :-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A

173

192959

1115.37

... More
Twin Control Point wiring in PVC conduit, with piano type switch :-Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

8

8862

1107.77

... More
Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :-Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

50

12697

253.94

... More
Circuit / Sub main wiring in PVC conduit :-Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.

65

11514

177.15

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.

280

58545

209.09

... More
2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire

290

96796

333.78

... More
2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire

130

56339

433.38

... More
2 x 16 sq.mm. + 1 x 6 sq.mm. Earth wire

45

26413

586.96

... More
4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire

45

34384

764.11

... More
S/F light plug point piano type accessories :-Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.

6

1633

272.19

... More
S/F power plug point piano type accessories :-Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.

47

17438

371.03

... More
Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

36

10099

280.55

... More
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

35

1064

30.41

... More
Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required :

-

-

-

... More
20 mm.

80

7785

97.32

... More
32 mm.

40

5596

139.9

... More
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.single pole

83

16155

194.64

... More
Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required.

6

59

9.88

... More
S/F DP MCB IsolatorSupplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc.63 Amps

2

801

400.68

... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 63 amps.

7

5503

786.16

... More
Supplying and fixing following way, SP&N, sheet steel, MCB distribution board, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) 6 way, Double door

2

3354

1677.24

... More
Supplying and fixing following way, horizontal type TP&N, sheet steel MCB distribution board, 415 V on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 4 way (4 + 12), Double door

2

6220

3110.42

... More
Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/ coke and salt as required.

4

22724

5681.03

... More
Supplying and laying 25 mm x 5 mm. G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

50

5474

109.48

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

45

24155

536.78

... More
Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required.

50

9276

185.52

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

50

2661

53.22

... More
Providing and fixing M.V. danger notice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription single red colour on FRLSont side as required.

5

1022

204.52

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

36

5069

140.81

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.5/6 A switch

6

469

78.31

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

6

2176

362.67

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

30

13366

445.54

... More
Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

180

28191

156.62

... More
Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

36

9278

257.74

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as requiredUpto 450 mm sweep

12

4105

342.14

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

36

74723

2075.64

... More
Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.

80

95200

1190

... More
Supply of 10 watt Mirror LED light fitting Confirming to IP 65 and above protection Complete in all respect.

10

10500

1050

... More
Supply and fixing of surface /PENDENT mounting round 10 to 15 watt led down lighter having power coated complete in all respect.

30

40500

1350

... More
Supply of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect.300 mm sweep

12

25200

2100

... More
Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.

-

-

-

... More
The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides.

-

-

-

... More
The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type

-

-

-

... More
Incoming -

-

-

-

... More
100 Amp MCCB-1 No.

-

-

-

... More
Outgoing -

-

-

-

... More
32 Amp MCCB - 3 No.

1

117200

117200

... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.

-

-

-

... More
16 sq. mm 4 core

70

24010

343

... More
35 sq. mm 3-1/2 core

75

31650

422

... More
50 sq. mm 3-1/2 core

30

14760

492

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

-

-

-

... More
16 sq. mm 4 core

4

939

234.94

... More
3½ X 35 sq. mm (35mm)

5

1402

280.55

... More
3½ X 50 sq. mm (35mm)

3

942

314.01

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil300 mm dia

60

30919

515.33

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.ection of Engineer -in-charge.100 mm nominal size dia

52

25455

489.52

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia

8

3999

499.9

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

3.77

5557

1474.1

... More
Development of tube well for 12" dia as per requirement and direction of Engineer-in-charge.

60

39000

650

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:100 mm dia

1

163

163.17

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp.

1

1391

1391.75

... More
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 100 mm dia.

1

193

193.03

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 40 mm dia nominal bore

50

22464

449.29

... More
1.5 HP 12 Stage, Single phase submersible pump of ISI mark with automatic panel. KSB/ Eqv.

1

15000

15000

... More
Supply and fixing of nylon jali around the slotted pipes complete as required. up to 10 meter

1

1000

1000

... More
Sypply and laying of alluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt brick on sides and on top. On surface the cable run shall be fixed on m.s clamps etc. of suitable size or as directed by the Engineer in charge , complete in all respect . the armouring of the cable shall be properly connected with the earth conductor by clamps etc.2.5 SQ.MM 3 core

70

6300

90

... More
Cartage of material upto site.

1

5000

5000

... More
Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

9

81900

9100

... More
Supply & fixing of CO2 type fire extinguisher, 4.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

9

107820

11980

... More
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift, outer side of plinth

1200

276000

230



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.