UP Jal Nigam Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

UP Jal Nigam - UPJN Tender

Works
Civil And Construction
Solid Waste Management
Drainage Work
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date1 Apr 2025
Closing Soon7 May 2025
Tender Amount₹ 24,38,06,000 
Notes
Download

AI Insights

Work Experience Requirements
... View More
The required prior work experience for the bidder includes: * Three Completed, tested and commissioned works each costing not less than the amount equal to 30% of estimated cost put to tender (i.e., Rs 731.42 lacs) * Two Completed, tested and commissioned works each costing not less than the amount equal to 40% of estimated cost put to tender (i.e., Rs 975.22 lacs) * One Completed, tested and commissioned work costing not less than the amount equal to 60% of estimated cost put to tender (i.e., Rs 1462.84 lacs) In terms of physical criteria, the bidder should have experience in: * Three Completed and commissioned works of STP of any proven technology on turnkey basis having minimum 2.55 MLD capacity each * Two Completed and commissioned works of STP of any proven technology on turnkey basis having minimum 3.40 MLD capacity each * One Completed and commissioned work of STP of any proven technology on turnkey basis having minimum 5.10 MLD capacity The experience of WWTP will also be considered for STP work. The performance certificate should be clear and exhaustive enough to establish similarity with the work under Bid. The bidder is required to submit a list of similar works executed during the last 10 years. However, specific details on the percentage of similar works completed are not mentioned, but monetary values are provided as mentioned above.
Bid Capacity
... View More
The formula for bid capacity is: Assessed Available Bid Capacity = 2 x A x N - B The variables used in the formula are defined as: - A = Maximum turnover during the last five financial years (corrected to the current level of value) - N = Stipulated period of execution of the work for which the tender is invited in years - B = Value of existing commitments to be completed during the execution period of bid

Costs

Summary

Interception And Diversion (i And D) And Stp For Existing Drain In Chandpur Town Npp Distt Bijnor

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(a) 0.00 to 1.50 m

3379.92

252

852077.83

... More
(b) 01.50 to 03.00 m

3275.23

317

1040344.06

... More
(c) 03.00 to 04.50 m

2543.9

399

1015575.76

... More
(d) 04.50 to 06.00 m

2122.22

471

1000032.51

... More
Provide and fix close timbering in trenches for the depth as specified below G.L. consisting of 40 mm thick approved country wood plank for polling board 125 x 75 mm eucalyptus-Safeda-Sal Wood wallers and 100 mm dia ballies for shuttering at 1.5 m C/C including all labour etc , complete

-

-

-

... More
(b) 03.00 to 06.00 m

2499.62

668

1670646.02

... More
Same as item No. 3 but for open timbering (No timbering for depth 1.50m)

-

-

-

... More
(a) 1.50 to 03.00 m

2046.98

292

598352.72

... More
Supply of Double Wall Corrugated (DWC) Pipes of Class SN8 Structured wall polyethelene piping systems (pipe with online/offline coupler and elastomeric sealling) with non-smooth external annular corrugated and smooth internal surface (double wall) for non pressure underground sewerage application as IS 16098 (Part-2):2013

-

-

-

... More
250 mm dia

238

398

94878.7

... More
Supply of Fittings (Couplers, Sealing rings, etc.) for Double Wall Corrugated (DWC) pipes of Class SN8 Structured wall polyethelene piping systems (pipe with online/offline coupler and elastomeric sealling) with non-smooth External Annular Corrugated and Smooth Internal Surface (Double Wall) for non pressure underground sewerage application as IS 16098 (Part-2):2013

-

-

-

... More
250 mm dia

40

164

6566

... More
Lowering, Laying and jointing of Double Wall Corrugated (DWC) pipes of Class SN8 Structured wall (External Annular Corrugated & Smooth Internal Surface) polyethelene pipe and fittings with the help of coupler (online/offline coupler) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the sepecified vally of the corrugation at the spigot end,loweing the same into the trench, laying on the lower bedding (constructed at bottom of the trenches) at prescribed gradient, depth & alignment, testing the water tightness of the joints, ensuring the continuity tests of specified pipe segments etc. complete as per drawing, specifications and detailed engineering, including carriage of pipes &fittings from site stacks to the place of laying etc. as per direction of Engineer-In-Charge. 250 mm dia pipe

-

-

-

... More
01.50 -0 3.00 m

143

79

11382.8

... More
03.00 - 04.50 m

95

84

8031.3

... More
Supply of following sizes of RCC spigotted and socketed non pressure pipes( Dia. In mm ) with structural strength as per IS 458 : 2003 and its latest amendment(s). NP3

-

-

-

... More
300 mm dia pipe

72

630

45429.84

... More
450 mm dia pipe

189

1360

257132.61

... More
600 mm dia pipe

23

2089

48049.3

... More
700 mm dia pipe

237

2513

595756.38

... More
900 mm dia pipe

248

4090

1014491.12

... More
1000 mm dia pipe

426

4780

2036539.86

... More
Carting following sizes of R.C.C. Hume pipe NP3 Class Socket / spigot rubber ring jointing and specials from store to the work lowering and laying the same in to the trenches upto depth as specified below G.L. true to alignment 300 mm dia pipe

-

-

-

... More
03.00 - 04.50 m

72

979

70499.52

... More
450 mm dia pipe

-

-

-

... More
03.00 - 04.50 m

189

1452

274431.78

... More
600 mm dia pipe

-

-

-

... More
03.00 - 04.50 m

23

1730

39793.68

... More
700 mm dia pipe

-

-

-

... More
04.50 - 06.00 m

237

2175

515548.47

... More
900 mm dia pipe

-

-

-

... More
04.50 - 06.00 m

248

2949

731446.24

... More
1000 mm dia pipe

-

-

-

... More
04.50 - 06.00 m

426

3517

1498599.84

... More
Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work.

-

-

-

... More
03.00 to 04.50 m

40.92

6534

267411.38

... More
04.50 to 06.00 m

710.22

6630

4709461.72

... More
Sand bedding for DWC Pipe including supply of all materials, labour, T&P etc. required for proper completion of work

-

-

-

... More
01.50 to 03.00 m

10.53

977

10296.13

... More
03.00 to 04.50 m

7

981

6871.83

... More
Construction of circular type brick masonry HD (HD25) manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:4 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) includingwith including Plastic Encapsulated M.S. foot Rest staggered at 0.375 mtr interval, including excavation, reinforcement

-

-

-

... More
900mm internal dia, 1.65m deep

2

15624

31249

... More
1200mm internal dia., 3.30m deep

14

38962

545480.6

... More
1500mm internal dia., 4.95m deep

25

106326

2658174.75

... More
1800mm internal dia, 9.00m deep(@60m c/c)

15

430455

6456835.35

... More
Extra for every additional depth of 1 m or part there of in following size of circular manholes.

-

-

-

... More
900mm internal dia., 1.65m deep

0.2

6335

-1267.12

... More
1200mm internal dia., 3.30m deep

2.3

9637

-22165.6

... More
1500mm internal dia., 4.95m deep

20

23468

-469368.2

... More
1800mm internal dia., 9.0 m deep

50

53629

-2681466.7

... More
Construction of Sewer Connecting chamber (0.6 x 0.6 x 3.0 m) including excavation, cement concrete (1:4:8) (40mm gauge) at the base, cement concrete (1:2:4) (20mm gauge), 1st class brick masonry (1:4), 12mm thick plaster inside the chamber and FRCS heavy duty manhole cover of size 0.6x0.6m including Plastic Encapsulated M.S. foot Rest staggered at 0.375 mtr interval, including excavation, reinforcement

27

22263

601121.47

... More
Extra for every additional depth of 1 m to regulate the depth of SCC

31.44

5472

172070.74

... More
Dismantling/Cutting of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer-incharge.

-

-

-

... More
Bituminous road

2527.85

170

431074.26

... More
Concrete road

2416.79

174

422044.04

... More
Interlocking tile road

2009.98

133

267950.43

... More
B.O.E road

362

90

32627.06

... More
Reinstatement of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer-incharge.

-

-

-

... More
Bituminous road

2527.85

1441

3642960.47

... More
Concrete road

2416.79

1296

3133513.24

... More
Interlocking tile road

2009.98

585

1176039.3

... More
B.O.E road

362

271

98134.58

... More
Tack & SDBC Coat on existing BT Road (remaining area after reinstatement)

2136.15

259

553412.38

... More
Provision for laying of sewer by trenchless technology Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating

-

-

-

... More
700 mm dia pipe,10mm Pipe Wall Thickness

522

16185

8448658.74

... More
1000 mm dia pipe,12mm Pipe Wall Thickness

500

27497

13748650

... More
Installation of product pipe by HDD method including preparing and setting up the plants and equipement, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per IndSTT:101:2018: Code of prectice of HDD Technique Suiting Indian Conditions. (depth up to 6m.

-

-

-

... More
700 mm dia pipe

522

11602

6056661.6

... More
1000 mm dia pipe

500

16744

8372355

... More
Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying.

1500

82

124485

... More
Land procurement for future expansion of STP

3000

1713

5141010

... More
Provision for shifting and reinstatement of electric and telephone poles during excavation and laying of sewer lines.

7

37881

265167.42

... More
Aproach road BT - 560m length [with RCC pipe culvert 1200m dia (Rs. 2.0 Lakh), 4m wide BT road (@1544.88/sqm, 2000 sqm with 1m wide BOE patri both side (@Rs.303.80/sqm, 1000sqm)]. Total 6m wide road.

560

6283

3518804.8

... More
Earth filling

1950

389

758823

... More
Road lighting pole 30 nos. with LED light25 Watt DC, 7.5 high pole fixing with PCC 1:2:4, 750mm depth, solar panel battery etc. all complete

30

22585

677566.2

... More
Construction of Boundary Wall 2.0 m ht. 0.23m thick above plinth level with RCC Column @3m c/c with plinth beam and foundation avg. 1.2m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site

600

6736

4042002

... More
MS gate (3.6m wide with 1.5m wicket gate with 0.35 x 0.35m RCC pillers)

1

48642

48642.12

... More
SEWAGE PUMPING STATION - IPS-1(Lifting Station) at Haldaur Road Drain Earthwork in excavation over areas (exceeding 1.5m in depth 1.5 in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5m, disposal earth to be leveled and neatly dressed.

-

-

-

... More
From 0 m to 1.5 m

48.4

252

12201.64

... More
From 1.5 m to 3 m

28.73

317

9125.8

... More
From 3 m to 4.5 m

13.07

399

5217.81

... More
Providing and laying in position cement concrete of specified grade all work upto plinth level in 1:3:6 (1 Cement : 3 coarse sand : 6 granded stone) 20 cm thick (3-4.5m depth)

5.68

5803

32963.43

... More
R.C.C. WITH CEMENT, COARSE SAND AND 20 MM STONE BALLAST 1:1.5:3 IN LINTELS OF DOORS AND WINDOWS.

-

-

-

... More
Floor slab

3.05

9821

29954.48

... More
Wall and bottom slabs

-

-

-

12.26

9821

120407.18

... More
1.5-3.0

4.66

9909

46178.41

... More
Bottom slab (3-4.5m)

3.58

8421

30147.25

... More
R.C.C. WITH CEMENT, COARSE SAND AND 20 MM STONE BALLAST 1:1.5:3 IN LINTELS OF DOORS AND WINDOWS.

-

-

-

... More
Roof Slab

2.23

9821

21901.14

... More
Roof Beam / Lintel Beam

3.75

9821

36829.28

... More
Reinforcement for R. C. C work including straightening, cutting, bending, placing in position and binding all complete.

2.63

89793

236157.72

... More
Brick work with bricks of class 1:4 cement mortor :Extra for Brick work in superstructure above plinth level upto floor V cum

3.99

5005

19973.42

... More
Cement plaster in course sand in 1:4 -12 mm thick (1 cement : 4 coarse sand)

29.35

172

5049.96

... More
Cement plaster in course sand in 1:4 -15 mm thick (1 cement : 4 coarse sand)

39.56

215

8508.57

... More
For shutters of doors, windows & ventilators including providing & fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required.

3.72

2471

9194.61

... More
Cement concrete flooring 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate ) finished with a floating coat of neat cement including cement slurry etc. but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate.

7.07

617

4363.82

... More
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work.

-

-

-

... More
Qty same as internal plastering for walls and ceiling

29.35

89

2640.62

... More
Appying one coat of cement primer of approved brand and manufacture on wall surface

-

-

-

... More
Qty same as extrnal plastering

39.56

89

3520.84

... More
Structural steel work in singal section fixed without connecting plate including cutting, hoisting, fixing in position and applying a primer coat of approved steel primer all complete.(such as I section, channels, M.S. chequered plates)

0.25

98189

24547.35

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm X 25 mm and overall minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30 X 20 X15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) complete as per standard design.

22

176

3884.1

... More
560mm dia C.I cover (heavey duty) the weight of the cover to be not less than 108 kg.

1

3972

3972.33

... More
Providing and fixing of CI gates of sizes testing and commissioning as per the specification and drawing.

60

88

5296.2

... More
Providing and fixing on wall face unplastidised-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.

20

441

8827.4

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth : consolidating each deposited layer by ramming and wateing lead.

28.91

119

3455.61

... More
Supplying and fixing of sluice valves

2

44137

88274

... More
Rising Main from Lifting Station

-

-

-

... More
Clearing jungle including uprooting of rank vegitation, grass, brush wood trees and saplings of girth upto 30cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50m outside the periphery of the area cleared.

1650

12

21367.5

... More
Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as per direction of Engineer-Incharge.

-

-

-

... More
0.0 to 1.5 mtr. Depth do - in all kindes of soil - 100%

1897.5

252

478359.75

... More
Supply of DI K7 Pipe confirming to relvant IS code or its latest amendment(s) including third party inspection charges, packing and forwarding charges, transit insurance, road transportation etc. all complete.

-

-

-

... More
150 mm dia.

2200

1525

3355968

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid (150mm Dia)

2

36734

73468.92

... More
Carting From Store, Laying, Jointing & Testing 150mm Dia Hdpe Pipe With Fitting Etc.

2200

77

170830

... More
Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, with cast insitu RCC slab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10 shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing.

-

-

-

... More
Sluice valve, Air valve chambers

2

15208

30416.46

... More
Dismantling/cutting of the BOE road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer-Incharge.

1650

90

148714.5

... More
Reinstatement of the BOE road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer-Incharge.

1650

271

447298.5

... More
Interception and diversion (I&D) Structure works

-

-

-

... More
Cnstruction of Interception and Diversion Structure works as per specification, accesory building & design approved by Engineer in Charge

2

514196

1028392.1

... More
Treated Effluent line (500mm Dia DI K7) (STP to Disposal point (Basta Road Canal)

-

-

-

... More
Clearing jungle including uprooting of rank vegitation, grass, brush wood trees and saplings of girth upto 30cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50m outside the periphery of the area cleared.

1650

13

22093.5

... More
Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as per direction of Engineer-Incharge.

-

-

-

... More
0.0 to 1.5 mtr. Depth do - in all kindes of soil

2475

252

623947.5

... More
Supply of ISI Marked A.C. Pressure Pipe confirming to IS-1592/2003 or itss latest amendment(s) including cost of one no. of AC coupling with a set of 3 rubber rings per meter length, including third party inspection charges, packing and forwaridng charges, transit insurance charges, road transportation charges etc. all complete. Class 15 AC Pipes conforming to IS-1592/2003 - 500 mm

1500

4921

7382430

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid (500mm Dia)

1

381473

381473.21

... More
Carting From Store, Laying, Jointing & Testing 500mm dia Class I & II A.C. Presure Pipe With specials and Fittings.

1500

249

374985

... More
Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, with cast insitu RCC slab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10 shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing.

-

-

-

... More
Sluice valve, Air valve chambers

1

14884

14884.65

... More
Dismantling/cutting of BOE road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materialsas per direction of Engineer-Incharge.

1590

90

143306.7

... More
Reinstatement of BOE road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer-Incharge.

1590

271

431033.1

... More
Cleaning of existing drains for smooth functioning of the system and disposal of silt and debris

1410

501

706522.8

... More
Strengthening of Existing Drains as and where required for uninterrupted functioning of the system

-

-

-

... More
Excavation in foundation in ordinary soil (loam, clay & sand) including lift upto 1.5m and lead upto 50m watering & ramming of excavated earth into the trenches or into the space between the building and the sides of the foundation or into the plinth and disposal of surplus earth as per direction of Engineer-Incharge. 0.00 to 1.50 m

525

252

132352.5

... More
Providing lay in PCC in following proportion in foundation and floor including supply of all materials, labour, T&P etc. complete required for the work 1:4:8 with coarse sand and 4cm gauge stone ballast.

-

-

-

33.6

3657

122893.34

... More
RCC work with cement, coarse sand and graded stone aggregate 20mm nominal size in proportion of 1:1.5:3 excluding supply of the reinforcement and its bending but including its fixing and binding with 0.5mm thick binding wire (to be supplied by the contractor) & including necessary centering and shuttering, supply of all materials labour, T&P etc. required for proper completion of work.

-

-

-

... More
Base slab

63

7503

472734.36

120

7503

900446.4

... More
Mild steel or iron work in R.C.C. work wrought to required shape as necessaty including bending for proper completion of work including supply of steel & wastage etc. In Slab

-

-

-

... More
in Slab

97.39

8081

787051.44

... More
Misc works

1

3177

3177.86

... More
E&M WORK AT STP ( 8.5 MLD ) And Co Treat ment Plant ( 12 KLD ) Design, Supply of all Materials, Erection, Testing,Commissioning and 3 month trial run Of Electrical, Mechanical & Instrumentation Equipments at STP (8.5 MLD ) with all required electrical & mechanical works, PLC/SCADA work, electrification & street lighting work etc. all complete as per tender document for STP.The effluent quality for agricultural uses ( PH-6.5 TO 8.3,SS-30 mg/l, Oil & Greases -10mg/l, BOD- 10mg/l,COD-30 mg/l,Residual Chlorine-nil, TKN-10mg/l, Nitrate-10mg/l, FC-230MPN/100ml Dissolved P-5mg/l (preferable 2mg/l).) shall be maintained as per CPHEEO mannuals Latest NGT norms for effluent discharge shall be adhered. The rate is Considered for SBR Technology. The STP shall be capable to treat the raw sewage having minimum concentration mentiond in CPHEEO mannual. Firm has to complete Design, Supply, Erection, Testing,Commissioning and 3 month trial run of Substation Work like HT Panel, Transformer & its associated equipments and DG Set Work with AMF Panel with considering load of STP and MPS both. Design, Supply of all Materials, Erection and Commissioning and 3 month Trial Run of Co-Treatment Plant ( 12 KLD ) having manual screen with-SS 304 with bar size (50 mm x 10mm) and gaping 20 mm, Screw Pumps (2 Kl/h 1W+1S), Screw Press Machine (2KL/H), all type pipe and fittings, LT panel and cabling material,Dewatering Pumps (1W+ 1S), 5HP Blower with 6 Nos Diffusers etc complete. including Supply and 3 month trial run. E./M. Works at MPS Electrical Works H.T.Panel( Comprising with 1 -I/C and 2 -O/G. SITC of Indoor Type Floor mounted HT Panel with 11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- (RATES ARE INCLUDED IN STP)

-

-

-

... More
Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement) - VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel. - Numerical relay (should be VCB manufacturer's own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI. - Ammeter with Selectorswitch and Volt meter with Selector switch - Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc. - Trip circuit supervision relay (feature of numerical relay) - LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. - 1 Set Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. 3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) - 1 Set Trench making and covering of trench in all respect. -1 Set SITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) - 1 Set 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV . - 1 Set (All Rates are included in STP)

-

-

-

... More
Transformer: with Off -LTC (+5% to - 10% @ 2.5%) : S I T C of Suitable size ( designrd as per Lload of stp & mps both) star rated Copper wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C & 40-45 degree C for above 800 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect.( 1working+1standby) - 2 Set D.G. SET AND ACCESSORIES SITC of Suitable size ( designed as per load of stp & mps both) of Radiator Cooled and Turbo charged Silent type DG set , engine ,alternator capable of developing at 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. It should comlpy CPCB 4 - 1 Set SITC of PLC Based Auto main failure (AMF) Panel for DG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect. - 1 Set Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. - 1 Job

-

-

-

... More
Plate Earthing as per IS:3043 with copper Earth plate of purity 95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. - 3 Job Supply & Laying 50 mm X 6mm size GI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. - 40 Met Providing and Laying cable for DG Set to Panel 300 sq mm X 3.5 core x 2 run( armored aluminium ) - 50 Met Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 300 sq mm. - 4 Job

1

54128273

54128273.5

... More
Design, Supply of all Materials, Erection and Commissioning and 3 month Trial Run of Co-Treatment Plant ( 12 KLD ) having manual screen with-SS 304 with bar size (50 mm x 10mm) and gaping 20 mm, Screw Pumps (2 Kl/h 1W+1S), Screw Press Machine (2KL/H), all type pipe and fittings, LT panel and cabling material,Dewatering Pumps (1W+ 1S), 5HP Blower with 6 Nos Diffusers etc complete. including Supply and 3 month trial run.

-

-

-

... More
Online Continuous Effluent Monitoring System (OCEMS) at STP outlet as per latest CPCB norms

1

4715000

4715000

... More
L.T. Panel SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operated on 415 ± 6 % volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii) C.Ts of suitable ratio- 1 No.(iii) Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v) Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi) Frequency meter-1 No.(vii) KWH meter - 1 No. (viii) 2 Pole over current relay& one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 6 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 160 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustable adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 3 Nos. outgoing panels for miscellaneous works, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (E)APFC Panel for total load.(F) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels

1

1674664

1674664.96

... More
LT Cable laying and jointing Power and control cable-Supply of 185 sq. mm 3.5 core cable - 2 Run required for power from each Transformer to each L.T. panel , 50 sq. mm X3 core-1 run cable for power from starters to Motor including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation system etc. complete in all respect.

1

432486

432486.95

... More
Earthing Plate Earthing as per IS:3043 with copper Earth plate of purity 95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.

4

14530

58122.68

... More
Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.

3

3495

10486.38

... More
Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing)

140

176

24717

... More
Charges of Electrical safety Clearance

-

-

-

... More
Expenditure on B&L Form, Challan etc.

1

9595

9595

... More
Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage)

1

115140

115140

... More
STARTER PANEL

-

-

-

... More
SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 30 HP motor (To be fixed in composite panel of LT Panel)

6

81557

489345

... More
Mechanical Works Pump The submersible non clog pumpset should be single stage having two vanes enclosed impeller coupled with submersible motor of 30 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (4W+2S) Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN. Impeller-Stainless steel CF-8M shaft-stainless steel AISI-410 Discharge of pump= 3110 lpm Total Head= 16 M Speed=980 Quantity of pumps. 06 nos. Guid Rail System Guide rail system (Automatic coupling system) for 30 HP submersible pump sets complete for above pump set. 06 sets Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle - 06 sets

-

-

-

... More
Quantity of pums

6

414594

2487565.16

... More
Main piping and Valves. Main piping and valves 200 mm dia delivery, 350 mm dia common header line. Valves. Confirming to IS 780/2906 or as applicable PN rating- 1.0 Type of liquid to be handled-potable water Material of construction Body-CI,IS-210 grade FG 200 Wedge-CI IS210 Grade FG200 Spindle-Stainless steel AISI304 Sheet and face Ring-SS ASTMA 743 Grade C.F.8 M Channel& Shoe-S.S.AISI,.304 Drain& Air plug-S.S.AISI.304 Bushing arrangement-Halprene on bronze Rivets-AISI:304 Fasteners-MS Motor Operated Sluice Valves

-

-

-

... More
Sluice Valve 200 mm dia

6

143925

863550

... More
Sluice Valve 350 mm dia

1

326230

326230

... More
Reflux valve 200 mm dia N.B.

6

45112

270676.86

... More
Note : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing taking 200mm pipe 60m and 400 mm pipe 15m .

-

-

-

... More
200 mm, K9 delivery pipes for all six pumping plant

60

2443

146631

... More
400 mm, K9 common header pipes

15

6207

93105.15

... More
Specials like bend, tee, D Joint etc.

1

11986

11986.79

... More
Nut Bolt, Washer Rubber packing etc .

1

12586

12586.14

... More
Installation & Commissioning of all 6 Nos. Pump set,Piping & Valves as mentioned in above.

1

421233

421233.08

... More
Level Transmitter (For Hi-Lo cut-off & alarms) SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display.

1

115140

115140

... More
Electro magnetic flow meter SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 400 mm dia main header line.

1

402990

402990

... More
E.O.T. Crane SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block.

1

644029

644029.83

... More
Chequerred plate and guards SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition (Ref. UP Jal Nigam, GM Gzb Rate) (3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm

235.17

97

22882.04

... More
PAINTING Painting of all pumps piping and valves with two coat enamel paint.

6

2878

17271

... More
LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019)

-

-

-

... More
Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan

1

19190

19190

... More
Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan

1

19190

19190

... More
IPS Campus with Solar Panel and LED Light of 3 sets.

1

86355

86355

... More
SCREENS AND GATES:

-

-

-

... More
Rising type thimble mounted CI Sluice Gates of reputed make at IPS

4

278255

1113020

... More
Multirake type Stainless steel ( SS-304) at peak load of full discharge, Mechanical Coarse Bar Screen-20 mm gaping), Ultrasonic type differential level sensor, control panel for coarse bar screens, belt coveyor etc. complete in all respect

1

2158875

2158875

... More
Stainless steel Manual Screen having bar size 50mmx10mm with (20 mm gaping) at peak load

1

211090

211090

... More
Packing and Frieght

1

104489

104489.55

... More
Installation, Testing and Commissioning

1

348298

348298.5

... More
AUTOMATION OF MPS CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places.

1

527725

527725

... More
GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification.

1

28785

28785

... More
CE/UL certified intellignet Smart Energy Meter

1

23987

23987.5

... More
Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 160 AMP rating

1

67165

67165

... More
Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator.

7

47975

335825

... More
CE/UL Certified Surge protector for control panel.

1

14392

14392.5

... More
CE/UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control ofp rocess parameters.

1

28785

28785

... More
Security Survillance IP Camera with recorder

1

19190

19190

... More
Installation, commissiong & testing of above automation work

1

19190

19190

... More
Trial run of automation work for 3 month period for MPS

1

14392

14392.5

... More
Three month trial run Expenditure on Operator (MPS) in 3 Shift

3

47495

142485.75

... More
Diesel Consumption During Trial and Run Period (MPS & STP)

1

214711

214711.24

... More
Electricity consumption during period of Trail and Run period of MPS &STP, payment done as per actual UPPCL Bill for MPS and STP,

1

978225

978225.2

... More
E./M. Works at IPS Chandpur Electrical Works

-

-

-

... More
L.T.Panel SITC of 0.415 kV IP 54 protected L.T. control panel for pumping plant-L.T. control panel suitable to operated on 415 ± 6 % volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming panels and 1 outgoing panel, each consisting of following items -(i) 4 pole MCCB With Thermal Magnetic release ,200Amp , 25 kA, adjustable O/L & adjustable S/C setting- 1 No.(ii) C.Ts of suitable ratio- 1 No.(iii) Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v) Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi) Frequency meter-1 No.(vii) KWH meter - 1 No. (viii) 2 Pole over current relay& one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 4 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB With Thermal Magnetic release ,100 Amp , 25 kA, adjustable O/L & adjustable S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 3 Nos. outgoing panels for miscellaneous works, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (E)APFC Panel for total load.(F) 4 pole MCCB With Thermal Magnetic release ,100 Amp , 25 kA, adjustable O/L & adjustable S/C setting Panel for DG set incoming - 1 NO.(G)Rubber resistance sheet and fire extinguisher complete in all respect.tion with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details-

1

476647

476647.6

... More
LT Cable laying and jointing Power and control cable-Supply of 25 sq. mm 3.5 core cable - 1Run required for power from Transformers to L.T. panel , 25 sq. mm X3 core-1 run cable for power from starters to all Motors including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation system etc. complete in all respect.

1

37540

37540.86

... More
Earthing Plate Earthing as per IS:3043 with copper Earth plate of purity 95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.

2

13807

27614.08

... More
Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.

2

3321

6642.77

... More
Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing)

80

167

13420.8

... More
Charges of Electrical safety Clearance Expenditure on B&L Form, Challan etc.

1

9117

9117.17

... More
STARTER PANEL

-

-

-

... More
SITC of Compraising of Variable Frequency Drive, suitable to meet the basic requirement of motor protections and suitable to run 12.5 HP motor -

2

68397

136794

... More
Mechanical Works Pumps The submersible non clog pumpset should be single stage having two vanes enclosed impeller coupled with submersible motor of 90 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (2W+1S) Casing-2% Ni Cl. IS.220 grade F.G.220 with hardness 275 BHN. Impeller-Stainless steel CF-8M shaft-stainless steel AISI-410 Discharge of pump= 1100 lpm Total Head= 24 M Speed=1450 RPM Quantity of pumps. -02 Nos. Guide rail system Guide rail system( 10 m each )(Automatic coupling system) for submersible pump sets complete for above pump - 2set. Lifting Chain- 10 met , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle - 2 sets

2

177106

354212.96

... More
Main piping and Valves. Main piping and valves 150 mm dia delivery, 150 mm dia common header line. Valves. Confirming to IS 780/2906 or as applicable PN rating- 1.0 Type of liquid to be handled-potable water Material of construction Body-CI,IS-210 grade FG 200 Wedge-CI IS210 Grade FG200 Spindle-Stainless steel AISI304 Sheet and face Ring-SS ASTMA 743 Grade C.F.8 M Channel& Shoe-S.S.AISI,.304 Drain& Air plug-S.S.AISI.304 Bushing arrangement-Halprene on bronze Rivets-AISI:304 Fasteners-MS

-

-

-

... More
Metal seated Sluice Valve 150 mm dia

2

32642

65284.4

... More
Motor operated metal seated Sluice Valve 150 mm dia for commom header.

1

113964

113964.61

... More
Reflux Valve

-

-

-

... More
Reflux valve 150 mm dia N.B.

2

25197

50394.24

... More
Piping Note : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing taking 150mm pipe 20m and 150 mm pipe 10 m .

-

-

-

... More
150 mm, K9 delivery pipes for all pumping plant

20

1724

34499.37

... More
150 mm, K9 common header pipes

10

1724

17249.68

... More
Specials like bend, tee, D Joint etc.

1

2587

2587.45

... More
Nut Bolt, Washer Rubber packing etc

1

2716

2716.01

... More
INSTALLATION, TESTING & COMMISSIONING Installation & Commissioning of all 2 Nos. Pump set,Piping & Valves as mentioned in above

1

64090

64090.95

... More
Level Transmitter (For Hi-Lo cut-off & alarms) SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display.

1

109406

109406.03

... More
Electro magnetic flow meter SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 5 MLD flow to be fitted in 150 mm dia main header line.

1

136757

136757.54

... More
H.O.T. Crane Providing, erecting triple spur gear type Chain Pulley Block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for 2 Tonn lift, tested to 50% over load as per IS 3832 carrying ISI mark with providing, erecting Travelling Trolley of 2 tonn capacity with 6 m lift, tested to 50% over load

1

33344

33344.22

... More
Chequerred plate and guards SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition (Ref. UP Jal Nigam, GM Gzb Rate) (3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm.

235.17

92

21743.16

... More
PAINTING Painting of all pumps piping and valves with two coat enamel paint.

2

2735

5470.3

... More
Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan

1

18234

18234.34

... More
IPS Campus with Solar Panel and LED Light of 3 sets.

1

82054

82054.52

... More
D.G. SET AND ACCESSORIES

-

-

-

... More
SITC of Radiator Cooled and Turbo charged Silent type DG set , engine ,alternator capable of developing 25 kVA at 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design.It shall comply CPCB-4

1

390123

390123.66

... More
SITC of PLC Based Auto main failure (AMF) Panel for 25 KVA DG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect.

1

64852

64852.25

... More
Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.

1

3321

3321.39

... More
Plate Earthing as per IS:3043 with copper Earth plate of purity 95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required.

2

13807

27614.08

... More
Supply & Laying 50 mm X 6mm size GI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.

30

370

11104.71

... More
Providing and Laying cable for DG Set to Panel 25 sq mm X 3.5 core x 1 run( armored aluminium )

30

259

7795.18

... More
Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 90 sq mm.

2

210

421.21

... More
SCREENS AND GATES:

-

-

-

... More
Rising type thimble mounted CI Sluice Gates of reputed make at IPS

2

100013

200026.86

... More
Stainless steel Manual Screen having bar size 50mmx10mm with 20 mm gaping at peak load.(1working+1standby)

2

154991

309983.75

... More
Packing and Frieght

1

9299

9299.51

... More
Installation, Testing and Commissioning

1

30998

30998.38

... More
AUTOMATION OF IPS

-

-

-

... More
CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places.

1

501444

501444.3

... More
GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification.

1

27351

27351.51

... More
CE/UL certified intellignet Smart Energy Meter

1

22792

22792.92

... More
Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 160 AMP rating

1

63820

63820.18

... More
Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator.

3

45585

136757.55

... More
CE/UL Certified Surge protector for control panel.

1

13675

13675.75

... More
CE/UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control ofp rocess parameters.

1

27351

27351.51

... More
Security Survillance IP Camera with recorder

2

18234

36468.68

... More
Installation, commissiong & testing of above automation work

1

18234

18234.34

... More
Trial run for 3 month period for IPS

1

13675

13675.75

... More
Three month Expenditure on Operator (IPS) in 3 Shift

3

45129

135389.97

... More
Diesel Consumption During Trial and Run Period (IPS)

1

40673

40673.63

... More
Electricity consumption during period of Trail and Run payment done as UPPCL Bill for IPS

1

103639

103639.98

... More
Cesspool Vehicle and Sewer Suction Cum Jetting Machine

-

-

-

... More
Cesspool Vehicle ( 1500 Litre Volumetric Capacity) having 5 mm thick steel plates. Complete equipment is mounted on reputed make Truck chassis with cabin BS 6 with all other specifications given in tender document (with Registration Certificate and insurance papers), with 3 month trial run.

1

1167000

1167000

... More
Sewer suction cum jetting machine (3000 Litre Volumetic Capacity), divided into two compartments of 1500 Liters for fresh water and 1500 Liters for sewer water. The complete equipment is mounted on Truck Chassis with cabin & PTO BS 6 ,rear door, tank level indicator, emptying system, tank mounting, drive system, high pressure jetting system, pressure relief valve, jetting hose reel, suction hose, suction pump, control panels, vaccume & pressure gauge etc complete as per specifications given in tender document (with Registration Certificate and insurance papers), with 3 month trial run.

1

2575000

2575000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.