UP Jal Nigam Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

UP Jal Nigam - UPJN Tender

Works
Civil And Construction
Drainage Work
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date1 Apr 2025
Closing Soon7 May 2025
Tender Amount₹ 15,63,92,000 
Notes
Download

AI Insights

Bid Capacity
... View More
The formula for Assessed Available Bid Capacity is 2 x A x N - B.
Technical Capacity
... View More
The required prior work experience for the bidder includes: * Three Completed, tested and commissioned works each costing not less than the Amount equal to 30% of estimated cost put to tender (i.e., Rs 469.18 lacs) * Two Completed, tested and commissioned works each costing not less than the amount equal to 40% of estimated cost put to tender (i.e., Rs 625.57 lacs) * One Completed, tested and commissioned work costing not less than the amount equal to 60% of estimated cost put to tender (i.e., Rs 938.35 lacs) Additionally, the bidder should have experience of similar works, which includes: * Three Completed, tested and commissioned works of STP of any proven technology on turnkey basis having minimum 30% capacity each (2.16 MLD) * Two Completed, tested and commissioned works of STP of any proven technology on turnkey basis having minimum 40% capacity each (2.88 MLD) * One Completed, tested and commissioned work of STP of any proven technology on turnkey basis having minimum 60% capacity each (4.32 MLD) The value and percentage of similar works completed are mentioned as follows: * The bidder should have successfully completed and commissioned similar works during the last ten years as on the date of publication of NIT, with specific values mentioned above. * The percentage of similar works completed is not explicitly mentioned, but the bidder is required to provide information on the contract value, which can be used to calculate the percentage. * The amount and percentage of non-achieved work value are mentioned as upto 10% of the non-achieved work value. No specific information is available on the minimum percentage of similar works completed, but the bidder is required to provide a list of similar works executed during the last 10 years as per Form-III&IIIA.

Costs

Summary

Interception And Diversion (i And D) And Stp For Existing Drain In Dhampur Town Npp Distt Bijnor

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(a) 0.00 to 1.50 m

1500.9

252

378377.39

... More
(b) 01.50 to 03.00 m

1222.57

317

388335.86

... More
(c) 03.00 to 04.50 m

538.7

399

215059.42

... More
Provide and fix close timbering in trenches for the depth as specified below G.L. consisting of 40 mm thick approved country wood plank for polling board 125 x 75 mm eucalyptus-Safeda-Sal Wood wallers and 100 mm dia ballies for shuttering at 1.5 m C/C including all labour etc , complete

-

-

-

... More
(a) 1.5 to 3 m

842.4

514

433209.25

... More
(b) 03.00 to 06.00 m

289.26

668

193470.52

... More
Same as item No. 3 but for open timbering (No timbering for depth 1.50m)

-

-

-

... More
(a) 1.50 to 03.00 m

259.92

292

75930.69

... More
Timbering left in trenches (No timbering for depth 1.50m)

-

-

-

... More
Open Timbering left in trenches (used timbering) 0-3m depth

5.2

582

3026.04

... More
Closed Timbering left in trenches(used timbering)0-3m depth

16.85

1123

18936.29

... More
Closed Timbering left in trenches(used timbering)3-6m depth

5.79

1410

8162.37

... More
Supply of following sizes of RCC spigotted and socketed non pressure pipes( Dia. In mm ) with structural strength as per IS 458 : 2003 and its latest amendment(s). NP3

-

-

-

... More
600 mm dia

633

2025

1281926.28

... More
700 mm dia

17

2436

41425.77

... More
Carting following sizes of R.C.C. Hume pipe NP3 Class Socket / spigot rubber ring jointing and specials from store to the work lowering and laying the same in to the trenches upto depth as specified below G.L. true to alignment 600 mm dia pipe

-

-

-

... More
01.50 - 0 3.00 m

164

1613

264544.14

... More
03.00 - 04.50 m

469

1713

803437.33

... More
700 mm dia pipe

-

-

-

... More
01.50 - 0 3.00 m

17

1898

32279.18

... More
Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work.

-

-

-

... More
(c) 03.00 to 04.50 m

111.53

6470

721654.87

... More
Filling granular material (well graded crushed rock or gravel maximum size 20mm) into the trenches for class B bedding (granular bedding) including watering compaction, labour T&P etc. for completion of work.

-

-

-

... More
(b) 01.50 to 03.00 m

44.25

123

5452.84

... More
Supply (excluding cartage) of granular material (well graded crushed rock or gravel of maximum size 20mm) for class B bedding (granular bedding)

44.25

2095

92739.15

... More
Construction of circular type brick masonry HD (HD25) manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:4 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete with including Plastic Encapsulated M.S. foot Rest staggered at 0.375 mtr interval, including excavation, reinforcement .

-

-

-

... More
1200mm internal dia., 3.30m deep

4

38787

155147.98

... More
1500mm internal dia., 4.95m deep

12

105846

1270163.63

... More
Extra for every additional depth of 1 m or part there of in following size of circular manholes.

-

-

-

... More
1200mm internal dia., 3.30m deep

7.44

9542

-70993.46

... More
1500mm internal dia., 4.95m deep

10.56

23236

-245381.2

... More
Dismantling/Cutting of Cement Concrete road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materialsas per direction of Engineer Incharge.

1308.01

172

226164.09

... More
Reinstatement of Concrete road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer Incharge.

1308.01

1099

1438689.36

... More
Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying.

130

82

10681.84

... More
Disposal of Surplus Earth as per direction of Engineer Incharge.

859.41

185

159805.57

... More
Construction of Boundary Wall 2.0m ht. above plinth level 0.23m width with RCC Column @3m c/c with plinth beam and foundation avg. 2 m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site

230

6797

1563333

... More
MS gate (3.6m wide with 1.50m wicket gate with 0.35 m x0.35m RCC piller)

1

48550

48550.7

... More
Cnstruction of Intermediate Pumping Station (IPS) as per specification, accesory building & design approved by Engineer in Charge

1

3159788

3159788.01

... More
Sewage Rising main from IPS Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as per direction of Engineer Incharge.

-

-

-

... More
0.0 to 1.5 mtr. Depth (do - in all kindes of soil)

3931.77

252

991199.22

... More
Supply of 400mm dia. DI K9 pipe and special for the pumping mains including all complete pipes conforming to IS : 8329 - 400 mm

4011

5447

21851005.47

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.(400mm)

1

122085

122085.25

... More
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete 150 mm

2

9732

19465.45

... More
Carting of 400mm dia DI K9 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc.

4011

224

901985.66

... More
Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, with cast insitu RCC slab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10 shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing

-

-

-

... More
Sluice valve, Air valve chambers

3

15208

45624.69

... More
Dismantling/cutting of the BOE road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m.

1916.7

76

147279.23

... More
Reinstatement of the BOE road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m.

1916.7

231

442987.7

... More
Interception and diversion (I&D) Structure works

-

-

-

... More
Cnstruction of Interception and Diversion Structure works as per specification, accesory building & design approved by Engineer in Charge

1

469967

469967.11

... More
Treated Effluent line (400mm Dia DI K7) (STP to Disposal point (Khow river)

-

-

-

... More
Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as directed, within a lead of 50 m. 0.0 to 1.5 mtr. Depth do - in all kindes of soil

1764

252

444704.4

... More
Supply of 400mm dia. DI K7 pipe and special for the pumping mains including all complete Pipes conforming to IS : 8329 - 400 mm

1800

5440

9792414

... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.all complete required for completion of work (400mm dia)

2

246226

492453.78

... More
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. all complete required for completion of work 150 mm

2

9732

19465.46

... More
Carting of 400mm dia DI K7 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc.

1800

224

404784

... More
Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, with cast insitu RCC slab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10 shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing.

-

-

-

... More
Sluice valve, Air valve chambers

4

15208

60832.92

... More
Dismantling/cutting of BOE road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m.

1260

76

96818.4

... More
Reinstatement of BOE road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m.

1260

231

291211.2

... More
E/M Work STP ( 7.2 MLD ) And Co Treat ment Plant ( 7 KLD ) Design, Supply of all Materials, Erection, Testing,Commissioning and 3 month trial run Of Electrical, Mechanical & Instrumentation Equipments at STP (7.2 MLD ) with all required electrical & mechanical works, PLC/SCADA work, electrification & street lighting work and Online Continuous Effluent Monitoring System (OCEMS) etc. all complete as per tender document for STP.The effluent quality for agricultural uses ( PH-6.5 TO 8.3,SS-30 mg/l, Oil & Greases -10mg/l, BOD- 10mg/l,COD-30 mg/l,Residual Chlorine-nil, TKN-10mg/l, Nitrate-10mg/l, FC-230MPN/100ml Dissolved P-5mg/l (preferable 2mg/l).) shall be maintained as per CPHEEO mannuals Latest NGT norms for effluent discharge shall be adhered. The rate is Considered for SBR Technology. The STP shall be capable to treat the raw sewage having minimum concentration mentiond in CPHEEO mannual. Firm has to complete Design, Supply, Erection, Testing,Commissioning and 3 month trial run of Substation Work like HT Panel, Transformer & its associated equipments and DG Set Work with AMF Panel with considering load of STP and MPS both. Design, Supply of all Materials, Erection and Commissioning and 3 month Trial Run of Co-Treatment Plant ( 7 KLD ) having manual screen with-SS 304 with bar size (50 mm x 10mm) and gaping 20 mm, Screw Pumps (1 Kl/h 1W+1S), Screw Press Machine (1KL/H), all type pipe and fittings, LT panel and cabling material,Dewatering Pumps (1W+ 1S), 2HP Blower with 6 Nos Diffusers etc complete. including Supply and 3 month trial run of 1 No. 1500 Lit. Cesspool Vehicle having 30 HP Reputed make Tractor (with Registration Certificate and insurance papers) E./M. Works at MPS, Electrical Works H.T.Panel( Comprising with 1 -I/C and 2 -O/G. SITC of Indoor Type Floor mounted HT Panel with 11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- 01 set of Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement) - VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel. - Numerical relay (should be VCB manufacturer's own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.

-

-

-

... More
Ammeter with Selectorswitch and Volt meter with Selector switch - Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc. - Trip circuit supervision relay (feature of numerical relay) - LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. 02 sets of Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement) - Numerical relay (should be VCB manufacturer's own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI. - Ammeter with Selectorswitch and Volt meter with Selector switch - Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc. - Trip circuit supervision relay (feature of numerical relay) - LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. 3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) - 60 meter Trench making and covering of trench in all respect. - 60 meter SITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) - 04 sets

-

-

-

... More
11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV -2.5 Sqm. Transformer: Suitable capacity with Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of suitable capacity rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. - 2 nos. D.G. SET AND ACCESSORIES SITC of Radiator Cooled and Turbo charged Silent type suitable capacity DG set , engine ,alternator capable of developing at 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. - 1 set SITC of PLC Based Auto main failure (AMF) Panel for DG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect. - 1 set Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. - 2 sets

-

-

-

... More
Plate Earthing as per IS:3043 with copper Earth plate of purity 95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. 2 jobs Supply & Laying 50 mm X 6mm size GI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.-1 job Providing and Laying cable for DG Set to Panel ( armored aluminium )- 01 job Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 185 sq mm. - 4 jobs

1

33347422

33347422.5

... More
L.T. Panel SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operated on 415 ± 6 % volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii) C.Ts of suitable ratio- 1 No.(iii) Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v) Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi) Frequency meter-1 No.(vii) KWH meter - 1 No. (viii) 2 Pole over current relay& one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 6 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 63 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustable adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 3 Nos. outgoing panels for miscellaneous works, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (E)APFC Panel for total load.(F) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels

1

1504395

1504395.92

... More
LT Cable laying and jointing Power and control cable-Supply of 185 sq. mm 3.5 core cable - 2 Run required for power from each Transformer to each L.T. panel , 50 sq. mm X3 core-1 run cable for power from starters to Motor including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation system etc. complete in all respect.

1

291219

291219.76

... More
Earthing Plate Earthing as per IS:3043 with copper Earth plate of purity 95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.

4

14530

58122.67

... More
Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.

3

3495

10486.38

... More
Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing)

140

176

24716.72

... More
Charges of Electrical safety Clearance

-

-

-

... More
Expenditure on B&L Form, Challan etc.

1

9595

9595

... More
Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage)

1

115140

115140

... More
STARTER PANEL

-

-

-

... More
SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel)

6

67165

402990

... More
Mechanical Works Pump The submersible non clog pumpset should be single stage having two vanes enclosed impeller coupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (4W+2S) Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN. Impeller-Stainless steel CF-8M shaft-stainless steel AISI-410 Discharge of pump= 3110 lpm Total Head= 16 M Speed=980 Quantity of pumps. 06 nos. Guid Rail System Guide rail system (Automatic coupling system) for 20 HP submersible pump sets complete for above pump set. 06 sets Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle - 06 sets

-

-

-

... More
Quantity of pums

6

339239

2035439.16

... More
Main piping and Valves. Main piping and valves 200 mm dia delivery, 350 mm dia common header line. Valves. Confirming to IS 780/2906 or as applicable PN rating- 1.0 Type of liquid to be handled-potable water Material of construction Body-CI,IS-210 grade FG 200 Wedge-CI IS210 Grade FG200 Spindle-Stainless steel AISI304 Sheet and face Ring-SS ASTMA 743 Grade C.F.8 M Channel& Shoe-S.S.AISI,.304 Drain& Air plug-S.S.AISI.304 Bushing arrangement-Halprene on bronze Rivets-AISI:304 Fasteners-MS Motor Operated Sluice Valves

-

-

-

... More
Sluice Valve 200 mm dia

6

143925

863550

... More
Sluice Valve 350 mm dia

1

287850

287850

... More
Reflux valve 200 mm dia N.B.

6

45112

270676.86

... More
Note : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing taking 200mm pipe 60m and 350 mm pipe 15m .

-

-

-

... More
200 mm, K9 delivery pipes for all six pumping plant

60

2443

146631

... More
350 mm, K9 common header pipes

15

5117

76755.15

... More
Specials like bend, tee, D Joint etc.

1

11169

11169.3

... More
Nut Bolt, Washer Rubber packing etc

1

11727

11727.76

... More
Installation & Commissioning of all 6 Nos. Pump set,Piping & Valves as mentioned in above.

1

370379

370379.91

... More
Level Transmitter (For Hi-Lo cut-off & alarms) SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display.

1

115140

115140

... More
Electro magnetic flow meter SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line.

1

316635

316635

... More
E.O.T. Crane SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating m

1

644029

644029.83

... More
Chequerred plate and guards SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition (Ref. UP Jal Nigam, GM Gzb Rate) (3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm.

235.17

97

22882.75

... More
PAINTING Painting of all pumps piping and valves with two coat enamel paint.

6

2878

17271

... More
LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019)

-

-

-

... More
Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan

1

19190

19190

... More
Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan

1

19190

19190

... More
IPS Campus with Solar Panel and LED Light of 3 sets.

1

86355

86355

... More
SCREENS AND GATES:

-

-

-

... More
Rising type thimble mounted CI Sluice Gates of reputed make at IPS

4

278255

1113020

... More
Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge

2

211090

422180

... More
Packing and Frieght

1

46056

46056

... More
Installation, Testing and Commissioning

1

153520

153520

... More
AUTOMATION OF MPS CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places.

1

527725

527725

... More
GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification.

1

28785

28785

... More
CE/UL certified intellignet Smart Energy Meter

1

23987

23987.5

... More
Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 160 AMP rating

1

67165

67165

... More
Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator.

7

47975

335825

... More
CE/UL Certified Surge protector for control panel.

1

14392

14392.5

... More
CE/UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control ofp rocess parameters.

1

28785

28785

... More
Security Survillance IP Camera with recorder

1

19190

19190

... More
Installation, commissiong & testing of above automation work

1

19190

19190

... More
Expenditure on Operation & Maintenance of MPS including automation, Diesel Consumption & Electricity Consuption During 3 month Trial and Run Period

1

1025705

1025705

... More
E./M. Works at IPS Dhampur Electrical Works H.T.Panel( Comprising with 1 -I/C and 2 -O/G. SITC of Indoor Type Floor mounted HT Panel with 11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details-

-

-

-

... More
Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement) - VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel. - Numerical relay (should be VCB manufacturer's own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI. - Ammeter with Selectorswitch and Volt meter with Selector switch - Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc. - Trip circuit supervision relay (feature of numerical relay) - LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator.

1

580448

580448.57

... More
Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement) - Numerical relay (should be VCB manufacturer's own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI. - Ammeter with Selectorswitch and Volt meter with Selector switch - Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc. - Trip circuit supervision relay (feature of numerical relay) - LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC)

2

560433

1120866.8

... More
Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc.

-

-

-

... More
3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers)

60

1405

84340.2

... More
SITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm)

4

7736

30945.8

... More
11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV

2.5

1960

4900.65

... More
Transformer: 315 KVA with Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of 315 KVA rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C , ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect.

2

974251

1948502.7

... More
L.T. Panel SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operated on 415 ± 6 % volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 No outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii) C.Ts of suitable ratio- 1 No.(iii) Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v) Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi) Frequency meter-1 No.(vii) KWH meter - 1 No. (viii) 2 Pole over current relay & one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 3 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 400 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustable adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 2 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 100 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustable adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (E) 3 Nos. outgoing panels for miscellaneous works, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (F)APFC Panel for total load.(G) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels

1

1634755

1634755.51

... More
LT Cable laying and jointing Power and control cable-Supply of 240 sq. mm 3.5 core cable - 2 Run required for power from each Transformer to each L.T. panel , 240 sq. mm X3 core-1 run cable for power from starters to 67 KW Motors & 35 sq. mm X3 core-1 run cable for power from starters to 15 KW Motors including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation system etc. complete in all respect.

1

458892

458892.39

... More
Earthing Plate Earthing as per IS:3043 with copper Earth plate of purity 95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.

4

14530

58122.68

... More
Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.

3

3495

10486.38

... More
Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing)

140

176

24717

... More
Charges of Electrical safety Clearance Expenditure on B&L Form, Challan etc.

1

9595

9595

... More
Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage)

1

115140

115140

... More
STARTER PANEL

-

-

-

... More
SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 90 HP motor (To be fixed in composite panel of LT Panel)

3

143925

431775

... More
SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel)

2

67165

134330

... More
Mechanical Works Large Pumps The submersible non clog pumpset should be single stage having two vanes enclosed impeller coupled with submersible motor of 90 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (2W+1S) Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN. Impeller-Stainless steel CF-8M shaft-stainless steel AISI-410 Discharge of pump= 5750 lpm Total Head= 40 M Speed=980 Quantity of pumps. -03 Nos. Guide rail system (Automatic coupling system) for 90 HP submersible pump sets complete for above pump set. - 3 sets Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle - 3 sets

3

1199117

3597353.55

... More
Small Pumps The submersible non clog pumpset should be single stage having two vanes enclosed impeller coupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (1W+1S) Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN. Impeller-Stainless steel CF-8M shaft-stainless steel AISI-410 Discharge of pump=2500 lpm Total Head= 17 M Speed=980 Quantity of pumps. - 02 Nos. Guid Rail System Guide rail system (Automatic coupling system) for 20 HP submersible pump sets complete for above pump set. 2 sets Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle - 2 sets

2

339239

678479.72

... More
Main piping and Valves. 200 mm dia delivery for small pumps and 250 mm dia delivery for large pumps, 350 mm dia common header line. Valves. Confirming to IS 780/2906 or as applicable PN rating- 1.0 Type of liquid to be handled-potable water Material of construction Body-CI,IS-210 grade FG 200 Wedge-CI IS210 Grade FG200 Spindle-Stainless steel AISI304 Sheet and face Ring-SS ASTMA 743 Grade C.F.8 M Channel& Shoe-S.S.AISI,.304 Drain& Air plug-S.S.AISI.304 Bushing arrangement-Halprene on bronze Rivets-AISI:304 Fasteners-MS Motor Operated Sluice Valves

-

-

-

... More
Sluice Valve 200 mm dia

2

143925

287850

... More
Sluice Valve 250 mm dia

3

182305

546915

... More
Sluice Valve 350 mm dia

1

287850

287850

... More
Reflux Valve

-

-

-

... More
Reflux valve 200 mm dia N.B.

2

45112

90225.62

... More
Reflux valve 250 mm dia N.B.

3

63259

189779.52

... More
Reflux Valve Note : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing .

-

-

-

... More
200 mm, K9 delivery pipes for small pumping plants

30

2443

73315.5

... More
250 mm, K9 delivery pipes for large pumping plants

45

3280

147623.85

... More
350 mm, K9 common header pipes

15

5117

76755.15

... More
Specials like bend, tee, D Joint etc.

1

14884

14884.72

... More
INSTALLATION, TESTING & COMMISSIONING

1

15628

15628.96

... More
Installation & Commissioning of all Pump set,Piping & Valves as mentioned in above @5% of supplied items.

1

300333

300333.08

... More
Level Transmitter (For Hi-Lo cut-off & alarms) SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display.

1

115140

115140

... More
Electro magnetic flow meter SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line.

1

316635

316635

... More
E.O.T. Crane SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block.

1

644029

644029.83

... More
Chequerred plate and guards SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition (3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm.

235.17

97

22882.04

... More
PAINTING Painting of all pumps piping and valves with two coat enamel paint.

5

2870

14350

... More
LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019)

-

-

-

... More
Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan

1

19190

19190

... More
Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan

1

19190

19190

... More
IPS Campus with Solar Panel and LED Light of 3 sets.

1

47975

47975

... More
D.G. SET AND ACCESSORIES

-

-

-

... More
SITC of Radiator Cooled and Turbo charged Silent type DG set , engine ,alternator capable of developing 250 kVA at 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design.

1

2304719

2304719

... More
SITC of PLC Based Auto main failure (AMF) Panel for 250 KVA DG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect.

1

181582

181582.5

... More
Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.

2

3495

6990.92

... More
Plate Earthing as per IS:3043 with copper Earth plate of purity 95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required.

2

14350

28700

... More
Supply & Laying 50 mm X 6mm size GI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.

40

176

7062

... More
Providing and Laying cable for DG Set to Panel 240 sq mm X 3.5 core x 2 run( armored aluminium ).

50

1662

83140.5

... More
Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 240 sq mm.

4

1126

4505.8

... More
SCREENS AND GATES:

-

-

-

... More
Rising type thimble mounted CI Sluice Gates of reputed make at IPS

4

259065

1036260

... More
Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge

1

206197

206197.5

... More
Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge

1

206292

206292.5

... More
Packing and Frieght

1

43465

43465.35

... More
Installation, Testing and Commissioning

1

144884

144884.5

... More
AUTOMATION OF IPS

-

-

-

... More
CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places.

1

550000

550000

... More
GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification.

1

30000

30000

... More
CE/UL certified intellignet Smart Energy Meter

1

25000

25000

... More
Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 160 AMP rating

1

70000

70000

... More
Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator.

6

50000

300000

... More
CE/UL Certified Surge protector for control panel.

1

15000

15000

... More
CE/UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters.

1

30000

30000

... More
Security Survillance IP Camera with recorder

1

20000

20000

... More
Installation, commissiong & testing of above automation work

1

20000

20000

... More
3 month trial run of automation work

1

15000

15000

... More
Expenditure on Operation & Maintenance of IPS including, Diesel Consumption & Electricity Consuption During 3 month Trial and Run Period

1

1424000

1424000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.