UP Jal Nigam Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

UP Jal Nigam - UPJN Tender

Works
Civil And Construction
Consultancy Services
Civil And Architectural Services
Water Storage And Supply
Eprocure
Opening Date7 Mar 2025
Closing Date3 Apr 2025
Tender Amount₹ 1,85,48,63,472.81 
This is an estimated amount, exact amount may vary.
Notes
Download

AI Insights

Bid Capacity
... View More
To determine the bid capacity required for a tender, the formula provided is: Assessed Available Bid Capacity = 2x AxN - B. Here, A represents the maximum turnover during the last five financial years, adjusted for the current value level; N is the stipulated execution period of the work in years; and B is the value of existing commitments to be completed during the bid's execution period. The available bid capacity must exceed the total estimated cost of the work for which the tender is invited.
Technical Capacity
... View More
The required prior work experience for the bidder is experience in executing similar type of works, with detailed experience certificates. The bidder needs to provide details of contracts of similar nature and complexity, including the total contract amount, value in specified currencies at completion, and other relevant details. The forms provided require the bidder to give information on prior work experience, including contract values, physical progress, and performance reports. The bidder is also required to provide details of works that are in progress, awarded, or bid, including the contract value, stipulated date of start and completion, and physical progress in percentage. As for the value and percentage of similar works completed, the bidder needs to provide the value of works remaining to be completed and the physical progress in percentage. However, specific values and percentages of similar works completed are not mentioned. The bidder is required to provide a performance report, which can be Very Good, Good, Fair, or Poor, but exact values and percentages are not specified. The information provided does not explicitly mention the required prior work experience for the bidder in terms of years or specific duration. The minimum experience requirements are mentioned, but the details are not provided. In terms of specific values, the bidder is required to provide the total contract amount in Rs, and the value of works remaining to be completed in Rs in Lacs, but no specific amount is mentioned as a requirement. The physical progress is required to be provided as a percentage, but no specific percentage is mentioned as a requirement.

Costs

Summary

Agra Water Supply Re-organization Scheme (trans Yamuna Zone-i And Ii) Package 2

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OHT of 1050KL Capacity, 30m Staging at Sub Zone 1.5 : Nawal Ganj-II

1

14637172

14637172

... More
OHT of 2750KL Capacity, 25m Staging at Sub Zone 1.6 : Kachhpura

1

31663500

31663500

... More
OHT of 2100KL Capacity, 27m Staging at Sub Zone 1.7 : Prakash Nagar

1

25198389

25198389

... More
Transyamuna-2 Proposed OHT

-

-

-

... More
OHT of 1650KL Capacity, 30m Staging at Sub Zone 2.4 : Nagla Rambal

1

20610060

20610060

... More
OHT of 1100KL Capacity, 30m Staging at Sub Zone 2.6 : Nauki Sarai

1

15332810

15332810

... More
OHT of 1000KL Capacity, 30m Staging at Sub Zone 2.7 : Ravinagar

1

13941535

13941535

... More
OHT of 2200KL Capacity, 30m Staging at Sub Zone 2.8 : Bhagwati Bagh

1

25887310

25887310

... More
OHT of 2650KL Capacity, 30m Staging at Sub Zone 2.9 : Tedi Baghiya

1

30540885

30540885

... More
OHT of 1250KL Capacity, 26m Staging at Sub Zone 2.10 : Kalandi Vihar-II

1

17396694

17396694

... More
OHT of 400KL Capacity, 26m Staging at Sub Zone 2.11 : Chhaleshar

1

7873657

7873657

... More
Transyamuna-1 Rehabilitation of OHT

-

-

-

... More
900KL OHT at Sub Zone 1.4 : Ex-Nawal Ganj-I

1

2633827

2633827

... More
Design, supply of all material, labour, T&P etc. required for construction of Ractangular, R.C.C Clear Water Reservoir cum pump house including various works like 1 m wide stair case with stainless steel hand railing to go inside reservoir, sump below the pump house area, stainless steel railing over the R.C.C slab of reservoir, Granular texture finish on exterior surface of pump house, gantry beam, food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, of capacity mentioned as under: Note : The bid prices of Clear Water Reservoir / Pumping Stations are to be submitted considering the depth of excavation may extend up to 6 m BGL.

-

-

-

... More
Transyamuna Zone-1

-

-

-

... More
1650 KL Zonal Pumping Station at Prakash Nagar for SZ 1.6 & 1.7

1

15435956

15435956

... More
Transyamuna Zone-2

-

-

-

... More
1950 KL Zonal Pumping Station at Tedi Bagiya for SZ 2.7, 2.8 & 2.9

1

17774737

17774737

... More
2350 KL Zonal Pumping Station at Kalindi Vihar-I for SZ 2.1,2.3,2.4,2.6 & 2.10

1

21420837

21420837

... More
150 KL Zonal Pumping Station at Chhalessar for SZ 2.11

1

2590650

2590650

... More
Rehabilitation of Existing CWR Cum Pumping Station

-

-

-

... More
Sita Nagar-1 (2800 KL) for SZ 1.1,1.2,1.3,1.4,1.5 & 1.8

1

7253820

7253820

... More
Sita Nagar-2 (800 KL)

1

4605600

4605600

... More
1200 KL Zonal Pumping Station at Nau ki Sarai for SZ 2.2 & 2.5

1

1266540

1266540

... More
Construction of Meter Room as per type design (Size - 4m x 4m x 4m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge.

4

481413

1925652

... More
Construction of Panel Room as per type design (Size - 5m x 5m x 4 m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge.

4

517290

2069160

... More
Construction of Chlorinating Room as per type design (Size - 6m x 4m x 4 m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge.

6

499927

2999562

... More
Construction of SCADA Control Room as per type design (Size - 10m x 4m x 4 m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge.

6

801618

4809708

... More
Raw Water Rising Main/Rising Main/Feeder Main/Distribution System & Miscellanious Works.

-

-

-

... More
Excavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters.

-

-

-

... More
0 to 1.5 m depth

237674.92

240

57253511.48

... More
1.5 to 3 m depth

19608

299

5870635.2

... More
Providing and supplying European Standard EN 639/1994 and EN 641/1994 or AWWA C-303 standard and reinforced concrete pressure pipes cylinder type or IS-15155-2002 (Bar wrapped steel cylinder pipes suitable for overlapping steel welded joint or butt welded steel joints) of following class and diameter including cost of all material and labour required, inspection charges, transportation to stores, transit insurance, loading, unloading and stacking excluding GST levied by GOI & GOM in all respect, etc. complete.

-

-

-

... More
1000mm dia Bar wrapped steel cylinder pipes

4800

17361

83333280

... More
900mm dia Bar wrapped steel cylinder pipes

2850

14283

40707690

... More
700mm dia Bar wrapped steel cylinder pipes

3300

9638

31806621

... More
500mm dia Bar wrapped steel cylinder pipes

5500

5754

31648705

... More
Manufacturing, providing and supplying spirally welded/ERW/ SAW/fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming 'V' edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking, excluding GST levied by GOI & GOM in all respect etc. complete as per IS-3589 and IS-5504 as applicable as per specifications (No negative tolerance in thickness is permissible). The cost is also inclusive of internel and externel apoxxy lining and coating.

-

-

-

... More
700mm dia (I.D.) (10mm thick)

550

18638

10251109

... More
800mm dia 10mm Thick MS pipes at Feeder Main from Jeoni Mandi WTP to Sita Nagar PS

4000

21263

85053240

... More
Supply of ISI mark DI K-9 and K-7 S&S pipes (push on joints) of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality, Bend, Tee etc.) including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking etc. complete as directed by Engineer –in-charge.

-

-

-

... More
D.I. Pipe Class-K9

-

-

-

... More
500mm dia

2600

9530

24779846

... More
400mm dia

7400

6827

50525054

... More
350mm dia

5115

5628

28790851.65

... More
300mm dia

11725

4581

53720549.75

... More
250mm dia

550

3608

1984719

... More
200mm dia

700

2688

1881761

... More
150mm dia

75

1996

149768.25

... More
D.I. Pipe Class-K7

-

-

-

... More
500 mm (DI-k7)

822

7976

6556304.88

... More
450 mm (DI-k7)

1631

6688

10908764.09

... More
400 mm (DI-k7)

2946

5669

16703466.48

... More
350 mm (DI-k7)

637

4661

2969643.04

... More
300 mm (DI-k7)

5011

3788

18981718.11

... More
250 mm (DI-k7)

9490

2949

27995310.2

... More
200 mm (DI-k7)

12718

2244

28551146.92

... More
Supply of High Density Polyethelene Pipes (HDPE (PN-6)/PE-100), conforming to IS 4984 / 14151 / 12786 / 13488 in coils/ standard lengths with nesessary jointing material like electro-fusion coupler, electro-fusion Tee, electro-fusion band, electro-fusion reducer, flanged joint, including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading & stacking the same in covered shade duly protecting from sunrays & rains, etc. complete as directed by Engineer –in-charge.

-

-

-

... More
110 mm (HDPE (PN-6)/PE-100)

195276

270

52837780.08

... More
140 mm (HDPE (PN-6)/PE-100)

26755

432

11577691.15

... More
160 mm (HDPE (PN-6)/PE-100)

13513

563

7610926.99

... More
Transporting of MS Pipe within 500 meters,laying in position to correct line and level M. S. specials pipes with / without any outcoating, such as distance pieces, straps, bends, tapers, etc. on prepared bedding in trenches including marginal cutting wherever required, assembling tack welding, the same. The rate to include loading, unloading, hoisting, etc. complete as specified.

-

-

-

... More
900mm dia to 1000mm dia Bar wrapped steel cylinder pipes

7650

1011

7740423

... More
500mm dia Bar wrapped steel cylinder pipes

5500

609

3352910

... More
700mm dia Bar wrapped steel cylinder pipes

3300

692

2284656

... More
Transporting of MS Pipe within 500 meters,laying in position to correct line and level M. S. specials pipes with / without any outcoating, such as distance pieces, straps, bends, tapers, etc. on prepared bedding in trenches including marginal cutting wherever required, assembling tack welding, the same. The rate to include loading, unloading, hoisting, etc. complete as specified.

-

-

-

... More
800mm dia (I.D.) 10mm Thick MS pipes

4000

1636

6544960

... More
700mm dia (I.D.) 10mm thick MS Pipes

550

5457

3001443.5

... More
Carting, lowering, laying and jointing with SBR ruber gaskets D.I. K-7/ D.I. K-9 pipes of following dia & pressure including all specials, to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge. It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work. The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note : Only SBR Rubber gaskets to be used as per IS-5382 and IS- 12820.

-

-

-

... More
D.I. Pipe Class-K9/K7

-

-

-

... More
500mm dia

3422

295

1009763.76

... More
450 mm dia

1631

251

410604.25

... More
400 mm dia

10346

208

2155692.56

... More
350mm dia

5752

171

987445.84

... More
300mm dia

16736

149

2497680.64

... More
250 mm dia

10040

115

1160021.6

... More
200mm dia

13418

85

1149251.7

... More
150mm dia

75

58

4402.5

... More
Carting, lowering, laying of following dia of HDPE Pipe (PN-6)/PE-100 of following dia and requisite specials to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge. It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work.The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note: Jointing between HDPE pipes and specials shall be done as per the latest IS: 7634 part II. Only Bar coded electro-fusion machine (Automatically Readable) that can read the bar code of the fittings automatically shall be used for jointing of HDPE pipe/fittings.

-

-

-

... More
110 mm (HDPE (PN-6)/PE-100)

195276

118

23202694.32

... More
140 mm (HDPE (PN-6)/PE-100)

26755

167

4488418.8

... More
160 mm (HDPE (PN-6)/PE-100)

13513

213

2879350.04

... More
Installation of HDPE/PE product pipe by HDD method including preparing and setting up the plant and equipment, making string of new ppe-work material, installing new pipe string and making the system ready for commissioning by HDD operation except sewer line and pipe pressure mains installation. including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pipe-work on the designed bore path alignment, propoer disposal of driling fluid and back fill after completion all inclusive as per IndSTT:101-2018: Code of Practice for Horizontal Directional Drilling Technique suiting Indian Conditions.

-

-

-

... More
110 mm (HDPE (PN-6)/PE-100)

97641

423

41315812.74

... More
Supply of following types of D.I. valves confirming to the I.S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality, dismantling joint or mechanical joint, Nut & Bolts etc.) including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking etc. complete as directed by Engineer –in-charge.

-

-

-

... More
Electrically Operated D.I. D/F Sluice valve, PN 1.6

-

-

-

... More
1000mm dia

1

2427040

2427040

... More
900mm dia

1

1956328

1956328

... More
800mm dia

2

1749077

3498154

... More
700mm dia

4

1057277

4229108

... More
500mm dia

8

408036

3264288

... More
400mm dia

1

303025

303025

... More
350mm dia

6

287850

1727100

... More
300mm dia

9

206292

1856628

... More
250mm dia

3

182305

546915

... More
200mm dia

2

143925

287850

... More
150mm dia

1

119937

119937

... More
Manually Operated D.I. D/F Sluice valve, PN 1.6

-

-

-

... More
100 mm

3

15603

46809

... More
125 mm

3

22834

68502

... More
200 mm

18

34048

612864

... More
250 mm

12

58139

697668

... More
300 mm

13

105368

1369784

... More
350 mm

6

157874

947244

... More
400 mm

3

210379

631137

... More
450 mm

4

304014

1216056

... More
500 mm

3

776565

2329695

... More
Scour valves, PN 1.6

-

-

-

... More
100mm dia

76

15603

1185828

... More
Fire Hydrant as per IS Code 908 : 1975

-

-

-

12

12362

148344

... More
Double Orifice Air Valve+Isolation Valve

-

-

-

... More
200mm dia

10

63866

638660

... More
150mm dia

16

52486

839776

... More
100mm dia

47

41571

1953837

76

35530

2700280

... More
50mm dia

110

28712

3158320

... More
Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge.

-

-

-

... More
D.I. D/F Sluice valve, Manually Operated / Electrically Operated PN 1.6

-

-

-

... More
1000mm dia

1

18791

18791

... More
900mm dia

1

16180

16180

... More
800mm dia

2

11588

23176

... More
700mm dia

1

10283

10283

... More
500mm dia

9

7286

65574

... More
450mm dia

4

6844

27376

... More
400mm dia

4

5249

20996

... More
350mm dia

12

4470

53640

... More
300mm dia

22

3343

73546

... More
250mm dia

15

3123

46845

... More
200mm dia

20

1980

39600

... More
150mm dia

1

1818

1818

... More
125mm dia

3

1288

3864

... More
100mm dia

3

1171

3513

... More
Scour valves, PN 1.6

-

-

-

... More
100mm dia

52

1171

60892

... More
Fire Hydrant as per IS Code 908 : 1975

-

-

-

... More
80 mm dia

12

875

10500

... More
Air valves, PN 1.6

-

-

-

... More
200mm dia

1

2136

2136

... More
150mm dia

5

1759

8795

... More
100mm dia

14

1168

16352

... More
50mm dia to 80mm dia

118

875

103250

... More
Supply of all materials, labour, T&P etc required for construction of RCC chambers for flow meter with M-30 Cement Concrete as per type design & drawing. as per the directions of Engineer-in- charge.

-

-

-

... More
Flow Meter Valve RCC Chambers

-

-

-

... More
900mm dia to 1000mm dia Flow Meter (Size- 2.1x 2.7x 3.4m)

2

623046

1246092

... More
700mm dia Flow Meter (Size- 2.0x 2.6x 3.2m)

1

398529

398529

... More
500mm dia Flow Meter (Size- 2.0x 2.6x 3.2m)

1

398529

398529

... More
Sluice valve RCC Chamber

-

-

-

... More
900mm dia to 1000mm dia Sluice Valve (Size- 2.7x 2.3x 3.5m)

2

619408

1238816

... More
700mm dia to 800mm dia Sluice Valve (Size- 2.6x 2.2x 3.3m)

6

395365

2372190

... More
Air valve RCC Chambers

-

-

-

... More
80mm to 200mm dia Air valve (Size- 1.2x 1.0x 2.4m)

18

70031

1260558

... More
Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design.

-

-

-

... More
Flow Meter Chambers

-

-

-

... More
300mm dia to 400mm dia Flow Meter Chamber (Size-1.7x 1.5x 1.5m)

12

41853

502236

... More
150mm dia to 250mm dia Flow Meter Chamber (Size-1.4x 1.3x 1.425m)

5

34494

172470

... More
500mm dia to 600mm dia Flow Meter Chamber (Size-2.2x 1.7x 1.6m)

5

53215

266075

... More
Sluice valve Chamber

-

-

-

... More
450mm dia to 600mm dia Sluice Valve Chamber (Size-1.7x 2.0x 2.6m)

15

87336

1310040

... More
300mm dia to 400mm dia Sluice Valve Chamber (Size-1.5x 1.7x 2.1m)

43

55288

2377384

... More
100mm dia to 250mm dia Sluice Valve Chamber (Size- 1.3x 1.4x 1.625m)

44

36730

1616120

... More
Air Valve Chambers

-

-

-

... More
100mm dia Air Valve (Size- 1.2x 1.4x 1.0m)

13

27851

362063

... More
50 mm dia to 80mm dia Air Valve Chamber (Size- 1.0x 1.3x 0.9m)

113

20503

2316839

... More
Scour Valve/Washout Chamber (Size 1.1x 1.2x 1.35m)

76

28900

2196400

... More
Fire Hydrant Chamber

12

4733

56796

... More
Dismantling of following type of road surfaces for laying of pipe line and house connection work including sorting out of serviceable materials and disposal of unserviceable materials including supply of all materials, labour, T&P etc. required for proper completion of the work.The rates of dismantling of roads as mentioned below for different types of roads include the cutting of existing thickness of road either single or multiple layer of roads. No extra payment shall be made to the contractor for cutting multiple layers of roads.

-

-

-

... More
Bituminious Road

132510.96

185

24538379.57

... More
Cement Concrete Road

17439.25

354

6174540.86

... More
Interlocking Tiles Road

33902.05

161

5487724.83

... More
Brick on edge Road (BOE)

7170.99

94

676654.62

... More
Re-instatement of following type of road surfaces after laying of pipe line and house connection work including supply of all materials, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement.

-

-

-

... More
Bitumen road TYPE A Construction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- GSB G-1 (One coat) (90-40 mm) = 12.5 cm G -2 (one coat) (45-63 mm) = 7.5 cm G - 3 (one coat) (22.5 - 53 mm) = 7.5 cm BM (One coat) = 7.5 cm SDBC (One coat) = 2.5 cm

132510.96

2399

317999801.81

... More
TYPE B Construction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- Bitumen Road (SDBC + Tack coat) SDBC (One coat) = 2.5 cm Tack coat with bituminous emulsion (MS) = 0.25 kg/sqm (30% consider for over dismantling of existing road)

26733.19

360

9641324.97

... More
Cement Concrete Road Construction of Cement Concrete road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- PCC = 100 mm,1:3:6 (cement, coarse sand & stone ballast of 20-40 mm) CC =100 mm, 1:1.5 :3 (cement, coarse sand & stone ballast of 16-20 mm)

17439.25

1206

21032956.25

... More
C.C. Interlocking Tiles Road Type A Construction of C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm) Sand = 30mm to 50mm thick local sand lair for preparation of surface Tiles = 50% new + 50% old Note : 80 mm thick rubber moulded interlocking tile shall be used for construction of interlocking tile road.

33902.06

1135

38481889.29

... More
BOE (Brick on Edge) Road Construction of BOE road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- Ist class brick shall be used for reinstatement of BOE road. Brick = 50% new + 50% old Sand = 25mm thick local sand layer for preparation of surface

7171

333

2390811.4

... More
Disposal of surplus earth /unserviceable material, by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.

12748.71

299

3816453.83

... More
Providing and laying in position reinforced cement concrete (mix 1:2:4) for construction of thurst block at bends of feeder main, rising main & distribution system including batching, mixing, placing, vibrating, curing, formwork, finishing, including cost of all material and labor, tools and plants required with transportation, loading, unloading, etc., complete for all leads and lifts etc required for proper completion of the work.

124.19

8076

1002984.52

... More
Providing H.Y.S.D steel reinforcement for reinforced cement concrete work including straightening, cutting, bending, hooking, placing in position, lapping and/ or welding wherever required, tying with binding wire and anchoring to the adjoining member wherever necessary as per design, including cost of materials and labor complete as per drawings.

14.39

9841

141634.98

... More
Repairing of sewer house connection which is coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work.

80

4560

364800

... More
Repairing of sewer man hole/ house connecting chamber which is coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work.

80

6751

540080

... More
Repairing / Shifting of existing water supply house connection due to falling in alignment of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work.

80

793

63440

... More
Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work.

-

-

-

... More
Brick masonry in cement mortar 1:4

120

5659

679089.6

... More
12mm thick plaster in cement mortar 1:4

4800

201

967968

... More
RCC M-20 (including MS work)

60

10413

624814.8

... More
Provision for crossing of Nalas for laying of pipe line using HDPE casing pipe of suitable dia. and length including labour, T&P, necessary arrangement for diversion & pumping of water if required, barricading etc required for proper completion of work as per directions of engineer-in-charge.

-

-

-

... More
0.3- 0.5 m (Clear Span)

120

4034

484080

... More
0.5 - 1.0 m (Clear Span)

96

6234

598464

... More
1.0 - 1.5 m (Clear Span)

48

7251

348048

... More
1.5 - 2.0 m (Clear Span)

24

12354

296496

... More
Supply of all material including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, laying and installing MS casing and carrier pipe crossing the National Highway and other roads for following sizes with trenchless technology by to correct line and level. The rate to include construction and removal of any jacking platforms, boring and jacking of pipe, removal of excavated material, jointing of casing sections, radiographic testing of joints, internal coating of casing pipe, providing HDPE spacers between the casing and carrier pipes, excavation of jacking and receiving pits, MS shoring/ shuttering, dewatering, 35 cm thick protection brick wall surrounding the pits for protection from entry of waste water of nearby drains, rain water or unwanted material for safety purpose, and backfilling of same to 95% of the standard Proctor density, etc., as indicated in the drawings and specifications. It includes supply of M.S. pipe with approved quality material from TATA/SAIL, epoxy coating in 300 micron thickness on both in and outside, welding material etc. After successful completion of laying, contractor shall fix blind plate at both the flanged ends of carrier pipe with rubber gasket, nut-bolts. After completion of aforesaid activities, contractor shall dismantle the shoring/shuttering taking all measures in consideration for safety, filling of earth in both pits in layers duly compacted up to 95% of density, filling of local sand in 1.0 m thick layer below the road surface. For safety caution/ diversion board with reflectors, caution tape, red blinker lights for night, hard baricading, traffic diversion, drainage diversion and pumping if required and other necessary arrangements for proper completion of the work up to the satisfaction of Engineer-in-charge.

-

-

-

... More
For 500 mm dia of Feeder Main Casing Pipe - 800 mm dia MS Pipe (10 mm thick) Carrier Pipe - 500 mm dia MS Pipe (6 mm thick)

30

79150

2374503.3

... More
For 1000 mm dia of Feeder Main Casing Pipe - 1200 mm dia MS Pipe (12 mm thick) Carrier Pipe - 1000 mm dia MS Pipe (10 mm thick)

35

146979

5144287.75

... More
Providing and making water supply house connection from distribution pipe line of following diameters using 20 mm dia pipe (HDPE pipe (PE 100/ PN 12.5) below ground and medium class GI pipe above ground), saddle (electro-fusion tapping saddle for making connection with HDPE distribution pipeline, DI strap saddle, ferrule, for making connection with distribution pipeline other than HDPE), compression fittings (FTA, MTA etc.), ball valve, specials, including supply of all materials, labour, T&P etc. required for proper completion of the work. It also includes excavation, refilling of pit required for making house connection.

-

-

-

... More
for 110 mm dia.

19260

3007

57914820

... More
for 125 mm -160 mm dia.

2267

3464

7852888

... More
for 200 mm -300 mm dia.

1134

3769

4274046

... More
Construction of Boundry wall around WTP, OHT & CWR Campus as per unit estimate with RCC Columns @ 3.0m c/c distance with plinth beam and brick work in 1:4 as per type design & drawing including supply of all materials T& P etc complete

8600

6746

58015600

... More
Supply and fixing 3.60 m wide MS main gate & 1.0 m wide a wicket gate with RCC Columns as per type design & drawing including primer and painting, meterial, labour, T&P etc all complete.

12

67323

807876

... More
Providing and laying in position reinforced cement concrete (mix 1:2:4) for construction of drain, size 250 mm x 250 mm, over PCC 1:4:8, including batching, mixing, placing, vibrating, curing, formwork, finishing, including cost of all material and labor, tools and plants required with transportation, steel, loading, unloading, etc., complete for all leads and lifts and as per specifications etc required for proper completion of the work.

5200

1487

7732400

... More
Construction of following types of Road/ flooring for development of CWR / OHT campus required as per site condition

-

-

-

... More
Bitumen road TYPE A Construction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- GSB G-1 (One coat) (90-40 mm) = 12.5 cm G -2 (one coat) (45-63 mm) = 7.5 cm G - 3 (one coat) (22.5 - 53 mm) = 7.5 cm BM (One coat) = 7.5 cm SDBC (One coat) = 2.5 cm

1400

2399

3359720

... More
C.C. Interlocking Tiles Road Construction of C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm) Sand = 50 mm thick local sand lair for preparation of surface Tiles = 100% new Note : 100 mm thick rubber moulded interlocking tile shall be used for construction of interlocking tile road.

1200

1530

1836480

... More
E&M Works

-

-

-

... More
Clear Water Pumping Station Zone-1

-

-

-

... More
Providing, erecting, commissioning and giving test and trial of VT pump set , water lubricated type and having following duty point,operating speed including providing and fixing ISMB grating etc including Suppy and delivery of Vertical hollow /solid shaft squirrel gauge induction motor (IS 325) suitable for the above pumps continuous rated TEFC/ SPDP type with class F insulation for operation in AC 3-phase/ 50Hz (+/- 5%), 415 volt (+/- 10%)running with the speed of pump noted above and with inbuilt thrust bearing assembly capable of taking of the entire load and non reverse ratchet assembly etc complete. The motor rating noted above is the minimum and shall be such that it should never be overloaded when the pump works at the MWL condition and shall be 10% over and above the maximum HP absorbed by the pump. The motor offered should be energy efficient to have maximum efficiency at high powerfactor. Separate thrust bearing assembly could also be supplied to takeup the down load. 1500 RPM, as per detailed specifications.

-

-

-

... More
Shahdra RM PUMP - Q=72.4LPS H=52m with suitable motor HP

2

2665491

5330982

... More
Nawal Ganj RM PUMP - Q=135.7LPS H=49m with suitable motor HP

2

2819970

5639941

... More
Kacchpura RM PUMP - Q=77.7LPS H=46m with suitable motor HP

2

2880419

5760838

... More
Prakash Nagar RM PUMP - Q=69.7LPS H=43m with suitable motor HP

2

2728818

5457636

... More
Providing, erecting and commissioning of Booster Pump Horizontal Slit Casing Centrifugal Booster pump suted for variable frequency drive to regulate the discharge as per demand.

-

-

-

... More
Booster Pump SZ 1.5 DMA-2 - Q=23.3LPS H=7m with suitable motor HP

2

2332544

4665089

... More
Booster Pump SZ 1.5 - Q=107.3LPS H=10m with suitable motor HP

2

3017627

6035255

... More
Booster Pump SZ 1.6 DMA-4 - Q=39.1LPS H=5m with suitable motor HP

2

2268258

4536516

... More
Providing, erecting and commissioning of Booster Pump Horizontal Slit Casing Centrifugal Booster pump suted for variable frequency drive to regulate the discharge as per demand.

-

-

-

... More
Pumping Main

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 200 mm

2

146803

293607

... More
Shahdra RM PUMP - 250 mm

2

177507

355015

... More
Nawal Ganj RM PUMP - 350 mm

2

248510

497021

... More
Kacchpura RM PUMP - 250 mm

2

177507

355015

... More
Prakash Nagar RM PUMP - 250 mm

2

177507

355015

... More
On Delivery Pipe of Booster Pump

-

-

-

... More
Booster Pump SZ 1.5 DMA-2 - 200 mm

2

146803

293607

... More
Booster Pump SZ 1.5 - 400 mm

2

272498

544996

... More
Booster Pump SZ 1.6 DMA-4 - 200 mm

2

146803

293607

... More
Supply of double flanged,DI, short body sluice valves with electrical actator and related hardware conforming to IS 14846, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications . Commonl Header, mm

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 300 mm

1

206292

206292.5

... More
Shahdra RM PUMP - 350 mm

1

287850

287850

... More
Nawal Ganj RM PUMP - 400 mm

1

326230

326230

... More
Kacchpura RM PUMP -350 mm

1

287850

287850

... More
Prakash Nagar RM PUMP -250 mm

1

182305

182305

... More
On Suction, Delivery Side & Main Pipe of Booster Pump.

-

-

-

... More
Booster Pump SZ 1.1 DMA-1 - 350 mm

1

287850

287850

... More
Booster Pump SZ 1.1 DMA-2 -300 mm

1

206292

206292.5

... More
Booster Pump SZ 1.1 DMA-3 - 350 mm

1

287850

287850

... More
Booster Pump SZ 1.5 DMA-2 - 200 mm

3

143925

431775

... More
Booster Pump SZ 1.5 - 400 mm

3

326230

978690

... More
Booster Pump SZ 1.6 DMA-4 - 200 mm

3

143925

431775

... More
Booster Pump SZ 1.8 DMA-3 - 200 mm

1

143925

143925

... More
Supply of flanged DI Kinetic air valve including isolated sluice valve and related hardware conforming to IS 14845 / C512, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications . Common Header

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 100 mm

1

41571

41571.3

... More
Shahdra RM PUMP - 100 mm

1

41571

41571.3

... More
Nawal Ganj RM PUMP - 100 mm

1

41571

41571.3

... More
Kacchpura RM PUMP - 100 mm

1

41571

41571.3

... More
Prakash Nagar RM PUMP - 80 mm

1

35530

35530.29

... More
On Delivery Pipe of Booster Pump

-

-

-

... More
Booster Pump SZ 1.5 DMA-2 - 80 mm

2

35530

71060.58

... More
Booster Pump SZ 1.5 -100 mm

2

41571

83142.6

... More
Booster Pump SZ 1.6 DMA-4 -80 mm

2

35530

71060.58

... More
Supply of dismantling joints and related hardware, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Individual Header, mm

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 200 mm

2

22625

45250.02

... More
Shahdra RM PUMP -250 mm

2

32882

65764.14

... More
Nawal Ganj RM PUMP -350 mm

2

49903

99807.2

... More
Kacchpura RM PUMP -250 mm

2

32882

65764.14

... More
Prakash Nagar RM PUMP -250 mm

2

32882

65764.14

... More
Commonl Header, mm

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) -300 mm

1

37775

37775.52

... More
Shahdra RM PUMP -350 mm

1

49903

49903.6

... More
Nawal Ganj RM PUMP - 400 mm

1

63653

63653.23

... More
Kacchpura RM PUMP - 350 mm

1

49903

49903.6

... More
Prakash Nagar RM PUMP - 250 mm

1

32882

32882.07

... More
Suction & Delivery Pipes of Booster Pumps,mm

-

-

-

... More
Booster Pump SZ 1.1 DMA-1 - 350 mm

1

49903

49903.6

... More
Booster Pump SZ 1.1 DMA-2 - 300 mm

1

37775

37775.52

... More
Booster Pump SZ 1.1 DMA-3 -350 mm

1

49903

49903.6

... More
Booster Pump SZ 1.5 DMA-2 - 200 mm

3

37775

113326.56

... More
Booster Pump SZ 1.5 - 400 mm

3

63653

190959.69

... More
Booster Pump SZ 1.6 DMA-4 - 200 mm

3

22625

67875.03

... More
Booster Pump SZ 1.8 DMA-3 - 200 mm

1

22625

22625.01

... More
Providing and supplying ISI mark DI D/F reflux valves (non-returnvalves ) of following dia including all railway freight, inspection chargesunloding from railway wagon,loading into truck, transportation upto departmental stroes/ site,unloading, stacking etc. complete. Reflux valves as per I.S.5312 Part I(1984).

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 200 mm

2

53732

107464

... More
Shahdra RM PUMP - 250 mm

2

94990

189981

... More
Nawal Ganj RM PUMP - 350 mm

2

217806

435613

... More
Kacchpura RM PUMP - 250 mm

2

94990

189981

... More
Prakash Nagar RM PUMP - 250 mm

2

94990

189981

... More
On Delivery Pipe of Booster Pump

-

-

-

... More
Booster Pump SZ 1.5 DMA-2 - 200 mm

2

53732

107464

... More
Booster Pump SZ 1.5 - 400 mm

2

284971

569943

... More
Booster Pump SZ 1.6 DMA-4 - 200 mm

2

53732

107464

... More
Providing, errecting, commissioning and testing of non clog sump pump set having pump discharge capacity of 30 LPS raw water with silt and mid at a total head of 30m with piping and other necessary arrangements. Q=30LPS, H=30m with suitable motor HP

5

226702

1133511

... More
Providing, fabricating, testing, transporting, and handling mild steel pipes and bends as per IS 5504, IS 3589 and the specifications and drawings. The rate to include transportation of pipes to site, loading, unloading, storage, guarding, and issuance to works as per specifications. The rates shall be inclusive of Collecting materials from storage, loading, transporting, unloading, laying and jointing/ welding pipe connections to correct line and level as per the specifications and drawings. The rate to include hoisting, lowering, marginal cutting wherever necessary, assembling, providing supports, thrust blocks, anchor blocks etc., as per specifications and drawings. The rate also includes testing of field joints . The rate shall also inclusive of internal and external epoxy coating and lining for corrosion protections as specified in the Specifications.

-

-

-

... More
Indivisual Header, mm

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 200 mm

10

5373

53732

... More
Shahdra RM PUMP - 250 mm

10

6428

64286.5

... More
Nawal Ganj RM PUMP - 350 mm

10

8731

87314.5

... More
Kacchpura RM PUMP - 250 mm

12

6428

77143.8

... More
Prakash Nagar RM PUMP - 250 mm

14

6428

90001.1

... More
Commonl Header, mm

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) -300 mm

10

7676

76760

... More
Shahdra RM PUMP - 350 mm

10

8731

87314.5

... More
Nawal Ganj RM PUMP - 400 mm

10

9786

97869

... More
Kacchpura RM PUMP - 350 mm

10

8731

87314.5

... More
Prakash Nagar RM PUMP - 250 mm

10

6428

64286.5

... More
Booster Pump Suction & Delivery Pipe

-

-

-

... More
Booster Pump SZ 1.1 DMA-1 - 350 mm

10

8731

87314.5

... More
Booster Pump SZ 1.1 DMA-2 - 300 mm

10

7676

76760

... More
Booster Pump SZ 1.1 DMA-3 - 350 mm

10

8731

87314.5

... More
Booster Pump SZ 1.5 DMA-2 - 200 mm

10

5373

53732

... More
Booster Pump SZ 1.5 - 400 mm

10

9786

97869

... More
Booster Pump SZ 1.6 DMA-4 - 200 mm

10

5373

53732

... More
Booster Pump SZ 1.8 DMA-3 - 200 mm

10

5373

53732

... More
Supply and errection of new Electrical Operated Crane (EOT) with chain pulley block complete. 5T and Above 8 m upto 10 m span

3

794466

2383398

... More
Providing and supplying ISI mark Electromagnetic Flow meter of following dia including all railway freight, inspection charges unloading from railway wagon, loading into truck, transportation up to departmental stores / site, unloading, stacking etc. complete.

-

-

-

... More
Rising Main

-

-

-

... More
Shahdra (SZ : 1.2 & 1.3) - 350 mm

1

316635

316635

... More
200 mm

1

182305

182305

... More
Nawal Ganj (SZ : 1.4, 1.5 & 1.8) - 500 mm

1

527725

527725

... More
300 mm

1

249470

249470

... More
300 mm

1

249470

249470

... More
300 mm

1

249470

249470

... More
Kacchpura (SZ : 1.6) -350 mm

1

316635

316635

... More
Prakash Nagar (SZ : 1.7) -300 mm

1

249470

249470

... More
OHT Outlet pipe

-

-

-

... More
Sita Nagar - 350 mm

1

316635

316635

... More
350 mm

1

316635

316635

... More
300 mm

1

249470

249470

... More
Shahdra-I - 250

1

215887

215887.5

... More
250 mm

1

215887

215887.5

... More
Shahdra-II - 300 mm

1

249470

249470

... More
Ex-Nawal Ganj-I - 300 mm

1

249470

249470

... More
250 mm

1

215887

215887.5

... More
Nawal Ganj-II - 400 mm

1

402990

402990

... More
Kachhpura - 500 mm

1

527725

527725

... More
Prakash Nagar - 400 mm

1

402990

402990

... More
Etmadaulah - 300 mm

1

249470

249470

... More
500 mm

1

527725

527725

... More
Spetials, fittings,Pressure gauge, Saddle,Nuts Bolts washers etc, cost, Work includes making connection with existing pipes etc

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised)

1

23987

23987.5

... More
Shahdra RM PUMP

1

23987

23987.5

... More
Nawal Ganj RM PUMP

1

23987

23987.5

... More
Kacchpura RM PUMP

1

23987

23987.5

... More
Prakash Nagar RM PUMP

1

23987

23987.5

... More
Providing, erecting and commissioning of Booster Pump set Horizontal Slit Casing Centrifugal Booster pump suted for variable frequency drive to regulate the discharge as per demand.

-

-

-

... More
Booster Pump SZ 1.1 DMA-1

1

14392

14392.5

... More
Booster Pump SZ 1.1 DMA-2

1

14392

14392.5

... More
Booster Pump SZ 1.1 DMA-3

1

14392

14392.5

... More
Booster Pump SZ 1.5 DMA-2

1

14392

14392.5

... More
Booster Pump SZ 1.5

1

14392

14392.5

... More
Booster Pump SZ 1.6 DMA-4

1

14392

14392.5

... More
Booster Pump SZ 1.8 DMA-3

1

14392

14392.5

... More
SITC of HYpochloride dosing system -2 tanks of 1500 lt ,Diaphragm pump- 2 no,VFD , Control panel with scada automation

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised)

1

741367

741367.27

... More
Shahdra RM PUMP

1

741367

741367.27

... More
Nawal Ganj RM PUMP

1

741367

741367.27

... More
Kacchpura RM PUMP

1

741367

741367.27

... More
Prakash Nagar RM PUMP

1

741367

741367.27

... More
Designing, supplying, installing, commissioning and testing of pilot operated hydraulically controlled Flow limiting cum Altitute Control Valve for ESR Inlet with level controlling and flow limiting application which maintains aconstant downstream rate of flow. Also, closes on high reservoir level (FSL). opens when reservoir level drops with fixed set points inclusive of all accessories like integral Float arrrangement pressure gauge etc. complete as per specification.

-

-

-

... More
Shahdra (SZ : 1.2 & 1.3) - 200 mm

1

219196

219196.43

... More
200 mm

1

219196

219196.43

... More
300 mm

1

384937

384937.58

... More
300 mm

1

384937

384937.58

... More
350 mm

1

560894

560894.53

... More
Nawal Ganj (SZ : 1.4, 1.5 & 1.8) - 300 mm

1

384937

384937.58

... More
Clear Water Pumping Station Zone-2

-

-

-

... More
Providing, erecting, commissioning and giving test and trial of VT pump set , water lubricated type and having following duty point,operating speed including providing and fixing ISMB grating etc including Suppy and delivery of Vertical hollow /solid shaft squirrel gauge induction motor (IS 325) suitable for the above pumps continuous rated TEFC/ SPDP type with class F insulation for operation in AC 3-phase/ 50Hz (+/- 5%), 415 volt (+/- 10%)running with the speed of pump noted above and with inbuilt thrust bearing assembly capable of taking of the entire load and non reverse ratchet assembly etc complete. The motor rating noted above is the minimum and shall be such that it should never be overloaded when the pump works at the MWL condition and shall be 10% over and above the maximum HP absorbed by the pump. The motor offered should be energy efficient to have maximum efficiency at high powerfactor. Separate thrust bearing assembly could also be supplied to takeup the down load. 1500 RPM, as per detailed specifications.

-

-

-

... More
Bhagwati Bagh RM PUMP - Q=68.7LPS H=46m with suitable motor HP

2

2585852

5171705

... More
Tedi Baghiya RM PUMP - Q=89.2LPS H=46m with suitable motor HP

2

2911123

5822246

... More
Chhalesar RM PUMP - Q=14.4LPS H=42m with suitable motor HP

2

2935110

5870221

... More
Nagla RM PUMP - Q=147.1LPS H=47m with suitable motor HP

2

2910163

5820327

... More
Nauki Sarai RM PUMP - Q=40.4LPS H=46m with suitable motor HP

2

223563

447127

... More
Kalandi Vihar RM PUMP - Q=45LPS H=43m with suitable motor HP

2

2451522

4903045

... More
Supply of double flanged DI short body pattern butterfly valve with electrical actuator with intregal starter and related hardware, including chair support, etc., conforming to IS 13095/BS EN 593, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 200 mm

2

146803

293607

... More
Bhagwati Bagh RM PUMP - 250 mm

2

177507

355015

... More
Tedi Baghiya RM PUMP - 300 mm

2

189981

379962

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 250 mm

3

177507

532522.5

... More
Chhalesar RM PUMP - 150 mm

2

122816

245632

... More
Nagla RM PUMP - 350 mm

2

248510

497021

... More
Nauki Sarai RM PUMP - 250 mm

2

177507

355015

... More
Kalandi Vihar RM PUMP - 250 mm

2

177507

355015

... More
Supply of double flanged,DI, short body sluice valves with electrical actuator with intregal starter and related hardware conforming to IS 14846, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Commonl Header, mm

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 250 mm

1

182305

182305

... More
Bhagwati Bagh RM PUMP - 300 mm

1

206292

206292.5

... More
Tedi Baghiya RM PUMP - 350 mm

1

287850

287850

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 350 mm

1

287850

287850

... More
Chhalesar RM PUMP - 150 mm

1

119937

119937.5

... More
Nagla RM PUMP -500 mm

1

450965

450965

... More
Nauki Sarai RM PUMP - 350 mm

1

287850

287850

... More
Kalandi Vihar RM PUMP -250 mm

1

182305

182305

... More
Commonl Header, mm

-

-

-

... More
Booster Pump SZ 2.5 DMA-1 - 200 mm

1

143925

143925

... More
Booster Pump SZ 2.5 DMA-4 - 350 mm

1

287850

287850

... More
Booster Pump SZ 2.5 DMA-3 - 300 mm

1

206292

206292.5

... More
Booster Pump SZ 2.5 DMA-2 -200 mm

1

143925

143925

... More
Booster Pump SZ 2.1 DMA-1&2 - 400 mm

1

326230

326230

... More
Booster Pump SZ 2.1 DMA-3 - 250 mm

1

182305

182305

... More
Supply of flanged DI Kinetic air valve including isolated sluice valve and related hardware conforming to IS 14845 / C512, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications . Common Header

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 80 mm

1

35530

35530.29

... More
Bhagwati Bagh RM PUMP - 100 mm

1

41571

41571.3

... More
Tedi Baghiya RM PUMP - 100 mm

1

41571

41571.3

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 100 mm

1

41571

41571.3

... More
Chhalesar RM PUMP - 80 mm

1

35530

35530.29

... More
Nagla RM PUMP - 100 mm

1

41571

41571.3

... More
Nauki Sarai RM PUMP - 100 mm

1

41571

41571.3

... More
Kalandi Vihar RM PUMP - 80 mm

1

35530

35530.29

... More
Supply of dismantling joints and related hardware, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Individual Header, mm

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 200 mm

2

22625

45250.02

... More
Bhagwati Bagh RM PUMP -250 mm

2

32882

65764.14

... More
Tedi Baghiya RM PUMP - 300 mm

2

37775

75551.04

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized -250 mm

3

32882

98646.21

... More
Chhalesar RM PUMP -150 mm

2

16330

32661.38

... More
Nagla RM PUMP - 350 mm

2

49903

99807.2

... More
Nauki Sarai RM PUMP - 250 mm

2

32882

65764.14

... More
Kalandi Vihar RM PUMP - 250 mm

2

32882

65764.14

... More
Commonl Header, mm

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 250 mm

1

32882

32882.07

... More
Bhagwati Bagh RM PUMP - 300 mm

1

37775

37775.52

... More
Tedi Baghiya RM PUMP - 350 mm

1

49903

49903.6

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 350 mm

1

49903

49903.6

... More
Chhalesar RM PUMP - 150 mm

1

16330

16330.69

... More
Nagla RM PUMP - 500 mm

1

92332

92332.69

... More
Nauki Sarai RM PUMP - 350 mm

1

49903

49903.6

... More
Kalandi Vihar RM PUMP - 250 mm

1

32882

32882.07

... More
Suction & Delivery Pipes of Booster Pumps,mm

-

-

-

... More
Booster Pump SZ 2.5 DMA-1 - 200 mm

1

22625

22625.01

... More
Booster Pump SZ 2.5 DMA-4 - 350 mm

1

49903

49903.6

... More
Booster Pump SZ 2.5 DMA-3 - 300 mm

1

37775

37775.52

... More
Booster Pump SZ 2.5 DMA-2 - 200 mm

1

22625

22625.01

... More
Booster Pump SZ 2.1 DMA-1&2 - 400 mm

1

63653

63653.23

... More
Booster Pump SZ 2.1 DMA-3 - 250 mm

1

32882

32882.07

... More
Providing and supplying ISI mark DI D/F reflux valves (non-returnvalves) of following dia including all railway freight, inspection chargesunloding from railway wagon,loading into truck, transportation upto departmental stroes/ site,unloading, stacking etc. complete. Reflux valves as per I.S.5312 Part I(1984).

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 200 mm

2

53732

107464

... More
Bhagwati Bagh RM PUMP - 250 mm

2

94990

189981

... More
Tedi Baghiya RM PUMP - 300 mm

2

137208

274417

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 250 mm

3

94990

284971.5

... More
Chhalesar RM PUMP - 150 mm

2

41258

82517

... More
Nagla RM PUMP - 350 mm

2

217806

435613

... More
Nauki Sarai RM PUMP - 250 mm

2

94990

189981

... More
Kalandi Vihar RM PUMP - 250 mm

2

94990

189981

... More
Providing, errecting, commissioning and testing of non clog sump pump set having pump discharge capacity of 30 LPS raw water with silt and mid at a total head of 30m with piping and other necessary arrangements.

-

-

-

... More
Q=30LPS, H=30m with suitable motor HP

5

226702

1133511

... More
Providing, fabricating, testing, transporting, and handling mild steel pipes and bends as per IS 5504, IS 3589 and the specifications and drawings. The rate to include transportation of pipes to site, loading, unloading, storage, guarding, and issuance to works as per specifications. The rates shall be inclusive of Collecting materials from storage, loading, transporting, unloading, laying and jointing/ welding pipe connections to correct line and level as per the specifications and drawings. The rate to include hoisting, lowering, marginal cutting wherever necessary, assembling, providing supports, thrust blocks, anchor blocks etc., as per specifications and drawings. The rate also includes testing of field joints . The rate shall also inclusive of internal and external epoxy coating and lining for corrosion protections as specified in the Specifications.

-

-

-

... More
Indivisual Header, mm

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 200 mm

10

5373

53732

... More
Bhagwati Bagh RM PUMP - 250 mm

10

6428

64286.5

... More
Tedi Baghiya RM PUMP - 300 mm

10

7676

76760

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 250 mm

18

8731

157166.1

... More
Chhalesar RM PUMP - 150 mm

14

4317

60448.5

... More
Nagla RM PUMP - 350 mm

16

8731

139703.2

... More
Nauki Sarai RM PUMP - 250 mm

18

6428

115715.7

... More
Kalandi Vihar RM PUMP - 250 mm

20

6428

128573

... More
Commonl Header, mm

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 250 mm

10

6428

64286.5

... More
Bhagwati Bagh RM PUMP - 300 mm

10

7676

76760

... More
Tedi Baghiya RM PUMP - 350 mm

10

8731

87314.5

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 350 mm

10

8731

87314.5

... More
Chhalesar RM PUMP - 150 mm

10

4317

43177.5

... More
Nagla RM PUMP - 500 mm

10

14680

146803.5

... More
Nauki Sarai RM PUMP - 350 mm

10

8731

87314.5

... More
Kalandi Vihar RM PUMP - 250 mm

10

6428

64286.5

... More
Supply and errection of new Electrical Operated Crane (EOT) with chain pulley block complete. 5 T and Above 8 m upto 10 m span

3

794466

2383398

... More
Providing and supplying ISI mark Electromagnetic Flow meter of following dia including all railway freight, inspection charges unloading from railway wagon, loading into truck, transportation up to departmental stores / site, unloading, stacking etc. complete. Rising mains

-

-

-

... More
Nauki Sarai (SZ: 2.6) - 250 mm

1

215887

215887.5

... More
Ravi Nagar (SZ : 2.7) - 250 mm

1

215887

215887.5

... More
Bhagwati Bagh : (SZ : 2.8 ) - 300 mm

1

249470

249470

... More
Tedi Baghiya (SZ : 2.9) -350 mm

1

316635

316635

... More
Kalandi Vihar-2 (SZ : 2.10) - 250 mm

1

215887

215887.5

... More
Chhalesar (SZ : 2.11) - 150 mm

1

143925

143925

... More
Nagla Rising Main (SZ : 2.1, 2.3 & 2.4) - 500 mm

1

738815

738815

... More
300 mm

1

633270

633270

... More
Nagla Rising Main (SZ : 2.1, 2.3 & 2.4) - 500 mm

1

527725

527725

... More
300 mm

1

249470

249470

... More
OHT Outlet pipe

-

-

-

... More
Transyamuna Ph-1 - 250 mm

1

215887

215887.5

... More
400 mm

1

402990

402990

... More
Naraich - 500 mm

1

527725

527725

... More
Nagla Jamuni - 400 mm

1

402990

402990

... More
Nagla Rambal - 250 mm

1

215887

215887.5

... More
300 mm

1

249470

249470

... More
250 mm

1

215887

215887.5

... More
Kalandi Vihar-I - 350 mm

1

316635

316635

... More
200 mm

1

182305

182305

... More
300 mm

1

249470

249470

... More
200 mm

1

182305

182305

... More
Nauki Sarai - 450 mm

1

479750

479750

... More
Ravinagar - 500

1

527725

527725

... More
Bhagwati Bagh - 200 mm

1

182305

182305

... More
300 mm

1

249470

249470

... More
400 mm

1

402990

402990

... More
Tedi Baghiya - 350 mm

1

316635

316635

... More
300 mm

1

249470

249470

... More
350 mm

1

316635

316635

... More
Kalandi Vihar-II - 400 mm

1

402990

402990

... More
250 mm

1

215887

215887.5

... More
Chhaleshar - 250 mm

1

215887

215887.5

... More
Spetials, fittings,Pressure gauge, Saddle,Nuts Bolts washers etc, cost, Work includes making connection with existing pipes etc

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised)

1

23987

23987.5

... More
Bhagwati Bagh RM PUMP

1

23987

23987.5

... More
Tedi Baghiya RM PUMP

1

23987

23987.5

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized

1

23987

23987.5

... More
Chhalesar RM PUMP

1

23987

23987.5

... More
Nagla RM PUMP

1

23987

23987.5

... More
Nauki Sarai RM PUMP

1

23987

23987.5

... More
Kalandi Vihar RM PUMP

1

23987

23987.5

... More
Booster Pump

-

-

-

... More
Booster Pump SZ 2.5 DMA-1

1

14392

14392.5

... More
Booster Pump SZ 2.5 DMA-4

1

14392

14392.5

... More
Booster Pump SZ 2.5 DMA-3

1

14392

14392.5

... More
Booster Pump SZ 2.5 DMA-2

1

14392

14392.5

... More
Booster Pump SZ 2.1 DMA-1&2

1

14392

14392.5

... More
Booster Pump SZ 2.1 DMA-3

1

14392

14392.5

... More
SITC of HYpochloride dosing system -2 tanks of 1500 lt ,Diaphragm pump- 2 no,VFD , Control panel with scada automation

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised)

1

741367

741367.27

... More
Bhagwati Bagh RM PUMP

1

741367

741367.27

... More
Tedi Baghiya RM PUMP

1

741367

741367.27

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized

1

741367

741367.27

... More
Chhalesar RM PUMP

1

741367

741367.27

... More
Nagla RM PUMP

1

741368

741368.23

... More
Nauki Sarai RM PUMP

1

741369

741369.19

... More
Kalandi Vihar RM PUMP

1

741370

741370.15

... More
Designing, supplying, installing, commissioning and testing of pilot operated hydraulically controlled Flow limiting cum Altitute Control Valve for ESR Inlet with level controlling and flow limiting application which maintains aconstant downstream rate of flow. Also, closes on high reservoir level (FSL). opens when reservoir level drops with fixed set points inclusive of all accessories like integral Float arrrangement pressure gauge etc. complete as per specification.

-

-

-

... More
Nauki Sarai (SZ: 2.6) - 250 mm

1

286074

286074.54

... More
Ravi Nagar (SZ : 2.7) - 300 mm

1

384937

384937.58

... More
Bhagwati Bagh : (SZ : 2.8 ) - 350 mm

1

560894

560894.53

... More
Tedi Baghiya (SZ : 2.9) - 700 mm

1

1778902

1778902.64

... More
Kalandi Vihar-2 (SZ : 2.10) - 150 mm

1

168311

168311.27

... More
Chhalesar (SZ : 2.11) - 500 mm

1

1322189

1322189.66

... More
Nagla Rising Main (SZ : 2.1, 2.3 & 2.4) - 700 mm

1

1778902

1778902.64

... More
500 mm

1

1322189

1322189.66

... More
Electrical & Instrumentation Works for the Zonal Pumping Station

-

-

-

... More
Electrical System

-

-

-

... More
Design, Supply, Installation, Testing and Commissioning of oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 400 KVA double wound with copper winding, ONAN with onload tap changer operated for voltage variation + 10.0 % to - 10% in step of 1.25%with their RTCC panel alongwith marshalling box, WTI, OTI, Buchholz relay etc conforming to releavent Indian Standards complete with standard fitting & accessories complete in all respect at B-1, 19.2 Tedi Bagiya Pumping Station

2

1068219

2136438.94

... More
Design, Supply, Installation, Testing and Commissioning of oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 160 KVA double wound with copper winding, ONAN with onload tap changer operated for voltage variation + 10.0 % to - 10% in step of 1.25%with their RTCC panel alongwith marshalling box, WTI, OTI, Buchholz relay etc conforming to releavent Indian Standards complete with standard fitting & accessories complete in all respect at B-1, 19.2 Nau ki Sarai Pumping Station

2

487439

974879.9

... More
Design, Supply, Installation, Testing and Commissioning of oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 400 KVA double wound with copper winding, ONAN with onload tap changer operated for voltage variation + 10.0 % to - 10% in step of 1.25%with their RTCC panel alongwith marshalling box, WTI, OTI, Buchholz relay etc conforming to releavent Indian Standards complete with standard fitting & accessories complete in all respect at B-1, 19.2 Kalindi ViharPumping Station

2

1068219

2136438.94

... More
Design, Supply, Installation, Testing and Commissioning of oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 250 KVA double wound with copper winding, ONAN with onload tap changer operated for voltage variation + 10.0 % to - 10% in step of 1.25%with their RTCC panel alongwith marshalling box, WTI, OTI, Buchholz relay etc conforming to releavent Indian Standards complete with standard fitting & accessories complete in all respect at B-1, 19.2 Prakash NagarPumping Station

2

648191

1296382.84

... More
SITC of 11kV indoor HT VCB Panel as per approved single line diagram at Tedi Bagiya Pumping Station

1

1453188

1453188.43

... More
SITC of 11kV indoor HT VCB Panel as per approved single line diagram at Nau ki Sarai Pumping Station

1

1453188

1453188.43

... More
SITC of 11kV indoor HT VCB Panel as per approved single line diagram at Kalindi ViharPumping Station

1

1453188

1453188.43

... More
SITC of 11kV indoor HT VCB Panel as per approved single line diagram at Prakash Nagar Pumping Station

1

1453188

1453188.43

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, Indoor Switch board PMCC panel (including 6 soft starters, Lighting and Power arrangements) at Tedi Bagiya Pumping Station

1

1917087

1917087.91

... More
SITC of 415 V, Indoor Switch board PMCC panel (including 2 soft starters, Lighting and Power arrangements) at Nau ki Sarai Pumping Station

1

711808

711808.72

... More
SITC of 415 V, Indoor Switch board PMCC panel (including 2 soft starters, Lighting and Power arrangements) at Chhalesar Pumping Station

1

578524

578524.1

... More
SITC of 415 V, Indoor Switch board PMCC panel (including 5 soft starters, Lighting and Power arrangements) at Kalindi Vihar Pumping Station

1

2237540

2237540.95

... More
SITC of 415 V, Indoor Switch board PMCC panel (including 6 soft starters, Lighting and Power arrangements) at Sita Nagar Pumping Station

1

2342916

2342916.5

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, Indoor Switch board PMCC panel (including 3 soft starters, Lighting and Power arrangements) at Prakash Nagar Pumping Station

1

1664670

1664670.52

... More
SITC of 415 V, APFC panel at Tedi Bagiya CWR Pumping Station

1

484085

484085.41

... More
SITC of 415 V, APFC panel at Nau KI Sarai Pumping Station

1

462502

462502.7

... More
SITC of 415 V, APFC panel at Chhalesar Pumping Station

1

447606

447606.46

... More
SITC of 415 V, APFC panel at Kalindi Vihar Pumping Station

1

484847

484847.06

... More
SITC of 415 V, APFC panel at Sita Nagar Pumping Station

1

514639

514639.53

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, APFC panel at Pra Kash Nagar Pumping Station

1

459228

459228.12

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - external lighting

6

88859

533155.8

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, utility sockets (3ph and 1ph.) and necessary accessories - internal lighting

6

137718

826313.7

... More
Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories

6

183775

1102653.18

... More
Complete cabling system with HV Power cables, cable trays, route marker, steel structure for cable trench, pipes and accessories

6

66727

400362.18

... More
Complete cabling system with LV power and control cables, cable trays, route marker, steel structure for cable trench, pipes and accessories

6

199007

1194042

... More
Start stop Push Button Stations

27

2139

57776.76

... More
AUTOMATION WORKS: Installation of Instrumentation and Control Equipment including, but not limited to, safe storage, protection, civil works, erection, installation, testing and commissioning required to complete the Works in all respects for the following equipment: Transyamuna Zonal Pumping Station

-

-

-

... More
CE & UL approved manufacturer's RTU/PLC suitable to communicate with GSM based modem unit with CPU and power supply with analog and digital parameter and features as specified for each tubewell & CWR to store and transmit data on GSM backbone. RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification sheet including Control panel with IP 54 protection industrial grade for all equipments (Separate for control (24 V) and power equipments) with CE / UL approved manufacturer’s Surge protector for Control Panel and CE / UL approved manufacturer’s 7" HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters as specified in tender technical specification sheet .

6

495041

2970247.92

... More
GSM/GPRS based wireless communicationmodem for RTU/PLC capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant as specified in tender technical specification sheet.

6

27002

162013.5

... More
CE / UL Certified 3 KVA UPS with batteries as per specification mentioned in technical bid documents.

6

135011

810067.62

... More
CE/UL approved manufacturer's Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. as per spec mentioned in technical bid documents.

6

22501

135011.28

... More
CE / UL approved manufacturer’s Radar type Level Transmitter for CWR as specified in tender technical specification sheet

6

108009

648054.12

... More
CE / UL approved manufacturer’s Pressure Transmitter in indivisual delivery line as well main header line of Pump as per specifications specified in tender technical specification sheet.

18

45003

810067.68

... More
CE/UL surge protector for control panel

6

13501

81006.78

... More
CE/UL Certified 7" HMI Touchscreen suitable to commuticate with PLC / RTU for loac display and control of process parameter.

6

27002

162013.5

... More
Complete control cable of all equipments at ZPS

6

72006

432036.06

... More
Control Panel with IP54 protection Indsutrial grade for all equipmets seprate for control (24 Volt) and power equipment.

6

135011

810067.62

... More
Complete instrumentation earthing system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories

6

46722

280332

... More
Security Surveillance IP Camera with Recorer

6

18001

108009

... More
Instaallation, Testing & Commissioning

6

18001

108009

... More
Trial Run for 3 Month

6

13501

81006.78

... More
Control cum Starting Panel for Booster Pumps with IP54 protection Indsutrial grade for all equipmets seprate for control (24 Volt) and power equipment.

6

135011

810067.62



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.