UP Jal Nigam Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

UP Jal Nigam - UPJN Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date4 Apr 2024
Closing DateCancelled
Tender Amount₹ 3,22,56,68,000 
Notes
Download

Costs

Summary

Agra Water Supply Re-organization Scheme (trans Yamuna Zone-i And Ii)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Design, Supply of all materials, labour, T&P etc required for construction of Intz type RCC Over Head Tank including various works like - Ventilator and Water level indicator, Lightening conductor, C.I. D/F Verticle pipes (Inlet Pipe, Outlet Pipe, Overflow Pipe & Washout Pipe), duck foot bend, puddle collers and bell mouths, Sluice valve on inlet, outlet & washout pipe and Valve Chamber, Bye-pass arrangement of OHT, Flooring with Apran & Drain( min.100 mm thick PCC of 1:2:4 & 100 mm thick RCC of 1:1.5:3 with nominal reinforcement), Floor level shall be 60 cm above the finished ground level of Campus, Three coat apex painting over one coat primer of approved colour after finishing of RCC surface with grinder, repair of pin holes, unevenness., Railings - G.I. Pipe railing around stair case (both sides), balcony & top dome periphery, S.S ladder from opening of top dome to bottom dome, Stair case (Seperate two column based RCC staircase and 1 m wide balcony with arrangement of M.S Gate and Jali), Food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, of capacity and staging mentioned as under: For bidding purpose, bearing capacity of soil shall be considered as 8t/sq.m. Working design shall be based on the SBC determind after soil investigation / 8 tonne/sqm. Note :- The bid price of Over Head Tanks is to be submitted considering net safe allowable bearing capacity as 8 t/m2, keeping the minimum foundation depth to be 2.5 m below existing ground level at the site of work. The successful bidder will be required to investigate the soil bearing capacity. If net safe allowable bearing capacity is found to be equivalent or more than 8 t/m2, the design of OHT will be based on 8 t/m2 capacity. However, in case the net safe allowable bearing capacity is found to be below 8 t/m2, then the design of OHT will be based on the actual bearing capacity.

-

-

-

... More
Transyamuna-1 Proposed OHT

-

-

-

... More
OHT of 450KL Capacity, 30m Staging at Sub Zone 1.3 : Shahdra-II

1

8340453

8340453

... More
OHT of 1050KL Capacity, 30m Staging at Sub Zone 1.5 : Nawal Ganj-II

1

14637172

14637172

... More
OHT of 2750KL Capacity, 25m Staging at Sub Zone 1.6 : Kachhpura

1

31663500

31663500

... More
OHT of 2100KL Capacity, 27m Staging at Sub Zone 1.7 : Prakash Nagar

1

25198389

25198389

... More
Transyamuna-2 Proposed OHT

-

-

-

... More
OHT of 1650KL Capacity, 30m Staging at Sub Zone 2.4 : Nagla Rambal

1

20610060

20610060

... More
OHT of 1100KL Capacity, 30m Staging at Sub Zone 2.6 : Nauki Sarai

1

15332810

15332810

... More
OHT of 1000KL Capacity, 30m Staging at Sub Zone 2.7 : Ravinagar

1

13941535

13941535

... More
OHT of 2200KL Capacity, 30m Staging at Sub Zone 2.8 : Bhagwati Bagh

1

25887310

25887310

... More
OHT of 2650KL Capacity, 30m Staging at Sub Zone 2.9 : Tedi Baghiya

1

30540885

30540885

... More
OHT of 1250KL Capacity, 26m Staging at Sub Zone 2.10 : Kalandi Vihar-II

1

17396694

17396694

... More
OHT of 400KL Capacity, 26m Staging at Sub Zone 2.11 : Chhaleshar

1

7873657

7873657

... More
Transyamuna-1 Rehabilitation of OHT

-

-

-

... More
900KL OHT at Sub Zone 1.4 : Ex-Nawal Ganj-I

1

2633827

2633827

... More
Design, supply of all material, labour, T&P etc. required for construction of Ractangular, R.C.C Clear Water Reservoir cum pump house including various works like 1 m wide stair case with stainless steel hand railing to go inside reservoir, sump below the pump house area, stainless steel railing over the R.C.C slab of reservoir, Granular texture finish on exterior surface of pump house, gantry beam, food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, of capacity mentioned as under: Note : The bid prices of Clear Water Reservoir / Pumping Stations are to be submitted considering the depth of excavation may extend up to 6 m BGL.

-

-

-

... More
Transyamuna Zone-1

-

-

-

... More
1650 KL Zonal Pumping Station at Prakash Nagar for SZ 1.6 & 1.7

1

15435956

15435956

... More
Transyamuna Zone-2

-

-

-

... More
1950 KL Zonal Pumping Station at Tedi Bagiya for SZ 2.7, 2.8 & 2.9

1

17774737

17774737

... More
2350 KL Zonal Pumping Station at Kalindi Vihar-I for SZ 2.1,2.3,2.4,2.6 & 2.10

1

21420837

21420837

... More
150 KL Zonal Pumping Station at Chhalessar for SZ 2.11

1

2590650

2590650

... More
Rehabilitation of Existing CWR Cum Pumping Station

-

-

-

... More
Sita Nagar-1 (2800 KL) for SZ 1.1,1.2,1.3,1.4,1.5 & 1.8

1

7253820

7253820

... More
Sita Nagar-2 (800 KL)

1

4605600

4605600

... More
1200 KL Zonal Pumping Station at Nau ki Sarai for SZ 2.2 & 2.5

1

1266540

1266540

... More
Construction of Meter Room as per type design (Size - 4m x 4m x 4m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge.

4

1925652

481413

... More
Construction of Panel Room as per type design (Size - 5m x 5m x 4 m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge.

4

2069160

517290

... More
Construction of Chlorinating Room as per type design (Size - 6m x 4m x 4 m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge.

6

2999562

499927

... More
Construction of SCADA Control Room as per type design (Size - 10m x 4m x 4 m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge.

6

4809708

801618

... More
Raw Water Rising Main/Rising Main/Feeder Main/Distribution System & Miscellanious Works.

-

-

-

... More
Excavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters.

-

-

-

... More
0 to 1.5 m depth

239984.92

57809967

240.89

... More
1.5 to 3 m depth

20322

6084406

299.4

... More
Providing and supplying European Standard EN 639/1994 and EN 641/1994 or AWWA C-303 standard and reinforced concrete pressure pipes cylinder type or IS-15155-2002 (Bar wrapped steel cylinder pipes suitable for overlapping steel welded joint or butt welded steel joints) of following class and diameter including cost of all material and labour required, inspection charges, transportation to stores, transit insurance, loading, unloading and stacking excluding GST levied by GOI & GOM in all respect, etc. complete.

-

-

-

... More
1100mm dia Bar wrapped steel cylinder pipes

700

15335586

21907.98

... More
1000mm dia Bar wrapped steel cylinder pipes

4800

83333280

17361.1

... More
900mm dia Bar wrapped steel cylinder pipes

2850

40707690

14283.4

... More
700mm dia Bar wrapped steel cylinder pipes

3300

31806621

9638.37

... More
500mm dia Bar wrapped steel cylinder pipes

5500

31648705

5754.31

... More
Manufacturing, providing and supplying spirally welded/ERW/ SAW/fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming 'V' edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking, excluding GST levied by GOI & GOM in all respect etc. complete as per IS-3589 and IS-5504 as applicable as per specifications (No negative tolerance in thickness is permissible). The cost is also inclusive of internel and externel apoxxy lining and coating.

-

-

-

... More
700mm dia (I.D.) (10mm thick)

550

10251109

18638.38

... More
800mm dia 10mm Thick MS pipes at Feeder Main from Jeoni Mandi WTP to Sita Nagar PS

4000

85053240

21263.31

... More
Supply of ISI mark DI K-9 and K-7 S&S pipes (push on joints) of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality, Bend, Tee etc.) including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking etc. complete as directed by Engineer –in-charge.

-

-

-

... More
D.I. Pipe Class-K9

-

-

-

... More
500mm dia

2600

24779846

9530.71

... More
400mm dia

7400

50525054

6827.71

... More
350mm dia

5115

28790851

5628.71

... More
300mm dia

11725

53720549

4581.71

... More
250mm dia

550

1984719

3608.58

... More
200mm dia

700

1881761

2688.23

... More
150mm dia

75

149768

1996.91

... More
D.I. Pipe Class-K7

-

-

-

... More
500 mm (DI-k7)

822

6556304

7976.04

... More
450 mm (DI-k7)

1631

10908764

6688.39

... More
400 mm (DI-k7)

2946

16703466

5669.88

... More
350 mm (DI-k7)

637

2969643

4661.92

... More
300 mm (DI-k7)

5011

18981718

3788.01

... More
250 mm (DI-k7)

9490

27995310

2949.98

... More
200 mm (DI-k7)

12718

28551146

2244.94

... More
Supply of High Density Polyethelene Pipes (HDPE (PN-6)/PE-100), conforming to IS 4984 / 14151 / 12786 / 13488 in coils/ standard lengths with nesessary jointing material like electro-fusion coupler, electro-fusion Tee, electro-fusion band, electro-fusion reducer, flanged joint, including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading & stacking the same in covered shade duly protecting from sunrays & rains, etc. complete as directed by Engineer –in-charge.

-

-

-

... More
110 mm (HDPE (PN-6)/PE-100)

195276

52837780

270.58

... More
140 mm (HDPE (PN-6)/PE-100)

26755

11577691

432.73

... More
160 mm (HDPE (PN-6)/PE-100)

13513

7610926

563.23

... More
Lowering and laying in position to correct line and level including M. S. specials such as distance pieces, straps, bends, tapers, etc. on pedestals or chairs upon piers or trestles. The rate to include loading, unloading, hoisting, marginal cutting wherever required, assembling and tack welding, and including transportation up to 500 m. etc. complete as specified. rate also inclusive of Hydraulic Testing

-

-

-

... More
1100mm dia Bar wrapped steel cylinder pipes

700

1262870

1804.1

... More
Transporting of MS Pipe within 500 meters,laying in position to correct line and level M. S. specials pipes with / without any outcoating, such as distance pieces, straps, bends, tapers, etc. on prepared bedding in trenches including marginal cutting wherever required, assembling tack welding, the same. The rate to include loading, unloading, hoisting, etc. complete as specified.

-

-

-

... More
900mm dia to 1000mm dia Bar wrapped steel cylinder pipes

7650

7740423

1011.82

... More
500mm dia Bar wrapped steel cylinder pipes

5500

3352910

609.62

... More
700mm dia Bar wrapped steel cylinder pipes

3300

2284656

692.32

... More
Transporting of MS Pipe within 500 meters,laying in position to correct line and level M. S. specials pipes with / without any outcoating, such as distance pieces, straps, bends, tapers, etc. on prepared bedding in trenches including marginal cutting wherever required, assembling tack welding, the same. The rate to include loading, unloading, hoisting, etc. complete as specified.

-

-

-

... More
800mm dia (I.D.) 10mm Thick MS pipes

4000

6544960

1636.24

... More
700mm dia (I.D.) 10mm thick MS Pipes

550

3001443

5457.17

... More
Carting, lowering, laying and jointing with SBR ruber gaskets D.I. K-7/ D.I. K-9 pipes of following dia & pressure including all specials, to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge. It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work. The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note : Only SBR Rubber gaskets to be used as per IS-5382 and IS- 12820.

-

-

-

... More
D.I. Pipe Class-K9/K7

-

-

-

... More
500mm dia

3422

1009763

295.08

... More
450 mm dia

1631

410604

251.75

... More
400 mm dia

10346

2155692

208.36

... More
350mm dia

5752

987445

171.67

... More
300mm dia

16736

2497680

149.24

... More
250 mm dia

10040

1160021

115.54

... More
200mm dia

13418

1149251

85.65

... More
150mm dia

75

4402

58.7

... More
Carting, lowering, laying of following dia of HDPE Pipe (PN-6)/PE-100 of following dia and requisite specials to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge. It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work.The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note: Jointing between HDPE pipes and specials shall be done as per the latest IS: 7634 part II. Only Bar coded electro-fusion machine (Automatically Readable) that can read the bar code of the fittings automatically shall be used for jointing of HDPE pipe/fittings.

-

-

-

... More
110 mm (HDPE (PN-6)/PE-100)

195276

23202694

118.82

... More
140 mm (HDPE (PN-6)/PE-100)

26755

4488418

167.76

... More
160 mm (HDPE (PN-6)/PE-100)

13513

2879350

213.08

... More
Installation of HDPE/PE product pipe by HDD method including preparing and setting up the plant and equipment, making string of new ppe-work material, installing new pipe string and making the system ready for commissioning by HDD operation except sewer line and pipe pressure mains installation. including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pipe-work on the designed bore path alignment, propoer disposal of driling fluid and back fill after completion all inclusive as per IndSTT:101-2018: Code of Practice for Horizontal Directional Drilling Technique suiting Indian Conditions.

-

-

-

... More
110 mm (HDPE (PN-6)/PE-100)

97641

41315812

423.14

... More
Supply of following types of D.I. valves confirming to the I.S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality, dismantling joint or mechanical joint, Nut & Bolts etc.) including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking etc. complete as directed by Engineer –in-charge.

-

-

-

... More
Electrically Operated D.I. D/F Sluice valve, PN 1.6

-

-

-

... More
1100mm dia

1

3509021

3509021

... More
1000mm dia

1

2427040

2427040

... More
900mm dia

1

1956328

1956328

... More
800mm dia

2

3498154

1749077

... More
700mm dia

4

4229108

1057277

... More
500mm dia

8

3264288

408036

... More
400mm dia

1

303025

303025

... More
350mm dia

6

1727100

287850

... More
300mm dia

9

1856628

206292

... More
250mm dia

3

546915

182305

... More
200mm dia

2

287850

143925

... More
150mm dia

1

119937

119937

... More
Manually Operated D.I. D/F Sluice valve, PN 1.6

-

-

-

... More
100 mm

3

46809

15603

... More
125 mm

3

68502

22834

... More
200 mm

18

612864

34048

... More
250 mm

12

697668

58139

... More
300 mm

13

1369784

105368

... More
350 mm

6

947244

157874

... More
400 mm

3

631137

210379

... More
450 mm

4

1216056

304014

... More
500 mm

3

2329695

776565

... More
Scour valves, PN 1.6

-

-

-

... More
100mm dia

76

1185828

15603

... More
Fire Hydrant as per IS Code 908 : 1975

-

-

-

12

148344

12362

... More
Double Orifice Air Valve+Isolation Valve

-

-

-

... More
200mm dia

12

766392

63866

... More
150mm dia

16

839776

52486

... More
100mm dia

47

1953837

41571

76

2700280

35530

... More
50mm dia

110

3158320

28712

... More
Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge.

-

-

-

... More
D.I. D/F Sluice valve, Manually Operated / Electrically Operated PN 1.6

-

-

-

... More
1100mm dia

1

20671

20671

... More
1000mm dia

1

18791

18791

... More
900mm dia

1

16180

16180

... More
800mm dia

2

23176

11588

... More
700mm dia

1

10283

10283

... More
500mm dia

9

65574

7286

... More
450mm dia

4

27376

6844

... More
400mm dia

4

20996

5249

... More
350mm dia

12

53640

4470

... More
300mm dia

22

73546

3343

... More
250mm dia

15

46845

3123

... More
200mm dia

20

39600

1980

... More
150mm dia

1

1818

1818

... More
125mm dia

3

3864

1288

... More
100mm dia

3

3513

1171

... More
Scour valves, PN 1.6

-

-

-

... More
100mm dia

52

60892

1171

... More
Fire Hydrant as per IS Code 908 : 1975

-

-

-

... More
80 mm dia

12

10500

875

... More
Air valves, PN 1.6

-

-

-

... More
200mm dia

3

6408

2136

... More
150mm dia

5

8795

1759

... More
100mm dia

14

16352

1168

... More
50mm dia to 80mm dia

118

103250

875

... More
Supply of all materials, labour, T&P etc required for construction of RCC chambers for flow meter with M-30 Cement Concrete as per type design & drawing. as per the directions of Engineer-in- charge.

-

-

-

... More
Flow Meter Valve RCC Chambers

-

-

-

... More
1100mm dia to 1200mm dia Flow Meter (SIZE - 3.8 x 3.0 x 3.6 m)

1

682051

682051

... More
900mm dia to 1000mm dia Flow Meter (Size- 2.1x 2.7x 3.4m)

2

1246092

623046

... More
700mm dia Flow Meter (Size- 2.0x 2.6x 3.2m)

1

398529

398529

... More
500mm dia Flow Meter (Size- 2.0x 2.6x 3.2m)

1

398529

398529

... More
Sluice valve RCC Chamber

-

-

-

... More
1100mm dia Sluice valve (Size- 2.8x 2.7x 3.7m)

1

680625

680625

... More
900mm dia to 1000mm dia Sluice Valve (Size- 2.7x 2.3x 3.5m)

2

1238816

619408

... More
700mm dia to 800mm dia Sluice Valve (Size- 2.6x 2.2x 3.3m)

6

2372190

395365

... More
Air valve RCC Chambers

-

-

-

... More
80mm to 200mm dia Air valve (Size- 1.2x 1.0x 2.4m)

20

1400620

70031

... More
Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design.

-

-

-

... More
Flow Meter Chambers

-

-

-

... More
300mm dia to 400mm dia Flow Meter Chamber (Size-1.7x 1.5x 1.5m)

12

502236

41853

... More
150mm dia to 250mm dia Flow Meter Chamber (Size-1.4x 1.3x 1.425m)

5

172470

34494

... More
500mm dia to 600mm dia Flow Meter Chamber (Size-2.2x 1.7x 1.6m)

5

266075

53215

... More
Sluice valve Chamber

-

-

-

... More
450mm dia to 600mm dia Sluice Valve Chamber (Size-1.7x 2.0x 2.6m)

15

1310040

87336

... More
300mm dia to 400mm dia Sluice Valve Chamber (Size-1.5x 1.7x 2.1m)

43

2377384

55288

... More
100mm dia to 250mm dia Sluice Valve Chamber (Size- 1.3x 1.4x 1.625m)

44

1616120

36730

... More
Air Valve Chambers

-

-

-

... More
100mm dia Air Valve (Size- 1.2x 1.4x 1.0m)

13

362063

27851

... More
50 mm dia to 80mm dia Air Valve Chamber (Size- 1.0x 1.3x 0.9m)

113

2316839

20503

... More
Scour Valve/Washout Chamber (Size 1.1x 1.2x 1.35m)

76

2196400

28900

... More
Fire Hydrant Chamber

12

56796

4733

... More
Dismantling of following type of road surfaces for laying of pipe line and house connection work including sorting out of serviceable materials and disposal of unserviceable materials including supply of all materials, labour, T&P etc. required for proper completion of the work.The rates of dismantling of roads as mentioned below for different types of roads include the cutting of existing thickness of road either single or multiple layer of roads. No extra payment shall be made to the contractor for cutting multiple layers of roads.

-

-

-

... More
Bituminious Road

133665.96

24752262

185.18

... More
Cement Concrete Road

17516.25

6201803

354.06

... More
Interlocking Tiles Road

34210.05

5537580

161.87

... More
Brick on edge Road (BOE)

7170.99

676654

94.36

... More
Re-instatement of following type of road surfaces after laying of pipe line and house connection work including supply of all materials, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement.

-

-

-

... More
Bitumen road TYPE A Construction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- GSB G-1 (One coat) (90-40 mm) = 12.5 cm G -2 (one coat) (45-63 mm) = 7.5 cm G - 3 (one coat) (22.5 - 53 mm) = 7.5 cm BM (One coat) = 7.5 cm SDBC (One coat) = 2.5 cm

133665.96

320771570

2399.8

... More
TYPE B Construction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- Bitumen Road (SDBC + Tack coat) SDBC (One coat) = 2.5 cm Tack coat with bituminous emulsion (MS) = 0.25 kg/sqm (30% consider for over dismantling of existing road)

26733.19

9641324

360.65

... More
Cement Concrete Road Construction of Cement Concrete road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- PCC = 100 mm,1:3:6 (cement, coarse sand & stone ballast of 20-40 mm) CC =100 mm, 1:1.5 :3 (cement, coarse sand & stone ballast of 16-20 mm)

17516.25

21125823

1206.07

... More
C.C. Interlocking Tiles Road Type A Construction of C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm) Sand = 30mm to 50mm thick local sand lair for preparation of surface Tiles = 50% new + 50% old Note : 80 mm thick rubber moulded interlocking tile shall be used for construction of interlocking tile road.

34210.06

38831497

1135.09

... More
BOE (Brick on Edge) Road Construction of BOE road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- Ist class brick shall be used for reinstatement of BOE road. Brick = 50% new + 50% old Sand = 25mm thick local sand layer for preparation of surface

7171

2390811

333.4

... More
Disposal of surplus earth /unserviceable material, by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.

13413.61

4015498

299.36

... More
Providing and laying in position reinforced cement concrete (mix 1:2:4) for construction of thurst block at bends of feeder main, rising main & distribution system including batching, mixing, placing, vibrating, curing, formwork, finishing, including cost of all material and labor, tools and plants required with transportation, loading, unloading, etc., complete for all leads and lifts etc required for proper completion of the work.

222.77

1799137

8076.21

... More
Providing H.Y.S.D steel reinforcement for reinforced cement concrete work including straightening, cutting, bending, hooking, placing in position, lapping and/ or welding wherever required, tying with binding wire and anchoring to the adjoining member wherever necessary as per design, including cost of materials and labor complete as per drawings.

26

255871

9841.23

... More
Repairing of sewer house connection which is coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work.

80

364800

4560

... More
Repairing of sewer man hole/ house connecting chamber which is coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work.

80

540080

6751

... More
Repairing / Shifting of existing water supply house connection due to falling in alignment of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work.

80

63440

793

... More
Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work.

-

-

-

... More
Brick masonry in cement mortar 1:4

120

679089

5659.08

... More
12mm thick plaster in cement mortar 1:4

4800

967968

201.66

... More
RCC M-20 (including MS work)

60

624814

10413.58

... More
Provision for crossing of Nalas for laying of pipe line using HDPE casing pipe of suitable dia. and length including labour, T&P, necessary arrangement for diversion & pumping of water if required, barricading etc required for proper completion of work as per directions of engineer-in-charge.

-

-

-

... More
0.3- 0.5 m (Clear Span)

120

484080

4034

... More
0.5 - 1.0 m (Clear Span)

96

598464

6234

... More
1.0 - 1.5 m (Clear Span)

48

348048

7251

... More
1.5 - 2.0 m (Clear Span)

24

296496

12354

... More
Supply of all material including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, laying and installing MS casing and carrier pipe crossing the National Highway and other roads for following sizes with trenchless technology by to correct line and level. The rate to include construction and removal of any jacking platforms, boring and jacking of pipe, removal of excavated material, jointing of casing sections, radiographic testing of joints, internal coating of casing pipe, providing HDPE spacers between the casing and carrier pipes, excavation of jacking and receiving pits, MS shoring/ shuttering, dewatering, 35 cm thick protection brick wall surrounding the pits for protection from entry of waste water of nearby drains, rain water or unwanted material for safety purpose, and backfilling of same to 95% of the standard Proctor density, etc., as indicated in the drawings and specifications. It includes supply of M.S. pipe with approved quality material from TATA/SAIL, epoxy coating in 300 micron thickness on both in and outside, welding material etc. After successful completion of laying, contractor shall fix blind plate at both the flanged ends of carrier pipe with rubber gasket, nut-bolts. After completion of aforesaid activities, contractor shall dismantle the shoring/shuttering taking all measures in consideration for safety, filling of earth in both pits in layers duly compacted up to 95% of density, filling of local sand in 1.0 m thick layer below the road surface. For safety caution/ diversion board with reflectors, caution tape, red blinker lights for night, hard baricading, traffic diversion, drainage diversion and pumping if required and other necessary arrangements for proper completion of the work up to the satisfaction of Engineer-in-charge.

-

-

-

... More
For 500 mm dia of Feeder Main Casing Pipe - 800 mm dia MS Pipe (10 mm thick) Carrier Pipe - 500 mm dia MS Pipe (6 mm thick)

30

2374503

79150.11

... More
For 1000 mm dia of Feeder Main Casing Pipe - 1200 mm dia MS Pipe (12 mm thick) Carrier Pipe - 1000 mm dia MS Pipe (10 mm thick)

35

5144287

146979.65

... More
Providing, fabricating and fixing expansion joints for pipelines as per the drawing. The rate to include machining the strakes and steel ring as shown in the drawing and welding on either automatic welding machine or manually, Rate includes plates and flats required for expansion joint and all other materials such as synthetic rubber, rubber ring, etc. including packing as per specifications, grease, bolts and nuts, local handling, excluding GST levied by GOI & GOM in all respect etc. complete.

2

514796

257398

... More
Providing and making water supply house connection from distribution pipe line of following diameters using 20 mm dia pipe (HDPE pipe (PE 100/ PN 12.5) below ground and medium class GI pipe above ground), saddle (electro-fusion tapping saddle for making connection with HDPE distribution pipeline, DI strap saddle, ferrule, for making connection with distribution pipeline other than HDPE), compression fittings (FTA, MTA etc.), ball valve, specials, including supply of all materials, labour, T&P etc. required for proper completion of the work. It also includes excavation, refilling of pit required for making house connection.

-

-

-

... More
for 110 mm dia.

19260

57914820

3007

... More
for 125 mm -160 mm dia.

2267

7852888

3464

... More
for 200 mm -300 mm dia.

1134

4274046

3769

... More
Construction of Boundry wall around WTP, OHT & CWR Campus as per unit estimate with RCC Columns @ 3.0m c/c distance with plinth beam and brick work in 1:4 as per type design & drawing including supply of all materials T& P etc complete

9725

65604850

6746

... More
Supply and fixing 3.60 m wide MS main gate & 1.0 m wide a wicket gate with RCC Columns as per type design & drawing including primer and painting, meterial, labour, T&P etc all complete.

15

1009845

67323

... More
Providing and laying in position reinforced cement concrete (mix 1:2:4) for construction of drain, size 250 mm x 250 mm, over PCC 1:4:8, including batching, mixing, placing, vibrating, curing, formwork, finishing, including cost of all material and labor, tools and plants required with transportation, steel, loading, unloading, etc., complete for all leads and lifts and as per specifications etc required for proper completion of the work.

7300

10855100

1487

... More
Construction of following types of Road/ flooring for development of CWR / OHT campus required as per site condition

-

-

-

... More
Bitumen road TYPE A Construction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- GSB G-1 (One coat) (90-40 mm) = 12.5 cm G -2 (one coat) (45-63 mm) = 7.5 cm G - 3 (one coat) (22.5 - 53 mm) = 7.5 cm BM (One coat) = 7.5 cm SDBC (One coat) = 2.5 cm

2200

5279560

2399.8

... More
C.C. Interlocking Tiles Road Construction of C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:- PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm) Sand = 50 mm thick local sand lair for preparation of surface Tiles = 100% new Note : 100 mm thick rubber moulded interlocking tile shall be used for construction of interlocking tile road.

1500

2295600

1530.4

... More
Construction of 1 set of double storey residential Staff Quarter (RCC framed structure) for providing of 4 no of staff quarters. There shall be two staff quarter at each floor (2GF+2FF). The plinth area of one staff quarter shall be min. 57.706 sqm. The total plinth area of each floor shall be minimum 115.412 sqm. (2x 57.706 sqm each) excluding area of common stair case but inclusive it's called in rates provided. The sum of total plinth area of one set of double storey building residential quarter shall be 2x115.412 = 230.824 sqm. The cost of construction of 1 set of double storey residential Staff Quarter includes supply of all materials, labour, T&P etc. required for proper completion of the work including supply of structural design and drawing, as per the directions of Engineer-in- charge.

6

24555552

4092592

... More
Construction of single storey residential Staff Quarter (RCC framed structure) for providing of 2 no of staff quarters. The plinth area of one staff quarter shall be min. 57.706 sqm. The total plinth area of floor shall be minimum 115.412 sqm. (2x 57.706 sqm each) excluding area of common stair case but inclusive it's called in rates provided. The cost of construction of 1 set of single storey residential Staff Quarter includes supply of all materials, labour, T&P etc. required for proper completion of the work including supply of structural design and drawing, as per the directions of Engineer-in- charge.

2

4393798

2196899

... More
E&M Works

-

-

-

... More
Raw Water Pumping Station on Jackwell

-

-

-

... More
Providing, erecting, commissioning and giving test and trial of VT pump set , water lubricated type and having following duty point,operating speed including providing and fixing ISMB grating etc including Suppy and delivery of Vertical hollow /solid shaft squirrel gauge induction motor (IS 325) suitable for the above pumps continuous rated TEFC/ SPDP type with class F insulation for operation in AC 3-phase/ 50Hz (+/- 5%), 415 volt (+/- 10%)running with the speed of pump noted above and with inbuilt thrust bearing assembly capable of taking of the entire load and non reverse ratchet assembly etc complete. The motor rating noted above is the minimum and shall be such that it should never be overloaded when the pump works at the MWL condition and shall be 10% over and above the maximum HP absorbed by the pump. The motor offered should be energy efficient to have maximum efficiency at high powerfactor. Separate thrust bearing assembly could also be supplied to takeup the down load. 1500 RPM as per detailed specifications.

-

-

-

... More
Raw Water Pump - Q=342.19LPS H=30m with suitable motor HP

5

21454420

4290884

... More
Supply of double flanged DI short body pattern butterfly valve with electrical actuator having integal starter and related hardware, including chair support, etc., conforming to IS 13095/BS EN 593, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Raw Water Pump - 600 mm

5

2365167

473033.5

... More
Supply of double flanged, DI, short body sluice valves with electrical actuator having integal starter and related hardware conforming to IS 14846, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Commonl Header - 1000 mm

1

2427040

2427040.86

... More
Indivisual Header - 600 mm

5

2508358

501671.7

... More
Supply of flanged DI Kinetic air valve including isolated sluice valve and related hardware conforming to IS 14845 / C512, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications.

-

-

-

... More
Common Header

-

-

-

... More
Raw Water Pump - 200 mm

1

63866

63866.24

... More
Supply of dismantling joints and related hardware, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Individual Header, mm

-

-

-

... More
Raw Water Pump - 600 mm

5

552576

110515.21

... More
Commonl Header, mm

-

-

-

... More
Raw Water Pump - 1000 mm

1

223832

223832.16

... More
Providing and supplying ISI mark DI D/F reflux valves (non-returnvalves ) of following dia including all railway freight, inspection chargesunloding from railway wagon,loading into truck, transportation upto departmental stroes/ site,unloading, stacking etc. complete. Reflux valves as per I.S.5312 Part I(1984).

-

-

-

... More
Pumping Main

-

-

-

... More
Raw Water Pump - 600 mm

5

3607720

721544

... More
Providing, errecting, commissioning and testing of non clog sump pump set having pump discharge capacity of 30 LPS raw water with silt and mid at a total head of 30m with piping and other necessary arrangements.

-

-

-

... More
Q=30LPS, H=30m with suitable motor HP

1

226702

226702.2

... More
Providing, fabricating, testing, transporting, and handling mild steel pipes and bends as per IS 5504, IS 3589 and the specifications and drawings. The rate to include transportation of pipes to site, loading, unloading, storage, guarding, and issuance to works as per specifications. The rates shall be inclusive of Collecting materials from storage, loading, transporting, unloading, laying and jointing/ welding pipe connections to correct line and level as per the specifications and drawings. The rate to include hoisting, lowering, marginal cutting wherever necessary, assembling, providing supports, thrust blocks, anchor blocks etc., as per specifications and drawings. The rate also includes testing of field joints . The rate shall also inclusive of internal and external epoxy coating and lining for corrosion protections as specified in the Specifications.

-

-

-

... More
Indivisual Header, mm

-

-

-

... More
Raw Water Pump - 600 mm

25

438971

17558.85

... More
Commonl Header, mm

-

-

-

... More
Raw Water Pump - 1000 mm

10

344460

34446.05

... More
Supply and errection of new Electrical Operated Crane (EOT) with chain pulley block complete 10 T and Above 8 m upto 10 m span

3

3160593

1053531

... More
Providing and supplying ISI mark Electromagnetic Flow meter of following dia including all railway freight, inspection charges unloading from railway wagon, loading into truck, transportation up to departmental stores / site, unloading, stacking etc. complete.

-

-

-

... More
Commonl Header

-

-

-

... More
Raw Water Pump - 1000 mm or suitable as per actual requirement.

1

527725

527725

... More
Spetials, fittings,Pressure gauge, Saddle,Nuts Bolts washers etc, cost, Work includes making connection with existing pipes etc

-

-

-

... More
Raw Water Pump

1

23987

23987.5

... More
Providing, erecting, commissioning and giving test and trial of VT pump set , water lubricated type and having following duty point,operating speed including providing and fixing ISMB grating etc including Suppy and delivery of Vertical hollow /solid shaft squirrel gauge induction motor (IS 325) suitable for the above pumps continuous rated TEFC/ SPDP type with class F insulation for operation in AC 3-phase/ 50Hz (+/- 5%), 415 volt (+/- 10%)running with the speed of pump noted above and with inbuilt thrust bearing assembly capable of taking of the entire load and non reverse ratchet assembly etc complete. The motor rating noted above is the minimum and shall be such that it should never be overloaded when the pump works at the MWL condition and shall be 10% over and above the maximum HP absorbed by the pump. The motor offered should be energy efficient to have maximum efficiency at high powerfactor. Separate thrust bearing assembly could also be supplied to takeup the down load. 1500 RPM, as per detailed specifications.

-

-

-

... More
Tedi Baghiya FM Pump : - Q=95.4LPS H=17m with suitable motor HP

4

10523796

2630949

... More
Etmadpur FM Pump : - Q=81.3LPS H=62m with suitable motor HP

4

11932342

2983085.5

... More
Transyamuna-I & II FM Pump :- Q=210.6LPS H=17m with suitable motor HP

5

15121720

3024344

... More
Supply of double flanged DI short body pattern butterfly valve with electrical actuator having integal starter and related hardware, including chair support, etc., conforming to IS 13095/BS EN 593, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Tedi Baghiya FM Pump : - 400 mm

4

1089992

272498

... More
Etmadpur FM Pump :- 250 mm

4

710030

177507.5

... More
Transyamuna-I & II FM Pump : - 400 mm

5

1362490

272498

... More
Supply of double flanged, DI, short body sluice valves with electrical actuator having integal starter and related hardware conforming to IS 14846, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Commonl Header, mm

-

-

-

... More
Tedi Baghiya FM Pump : - 500 mm

1

450965

450965

... More
Etmadpur FM Pump : - 300 mm

1

206292

206292.5

... More
Transyamuna-I & II FM Pump :- 800 mm

1

721544

721544

... More
Supply of flanged DI Kinetic air valve including isolated sluice valve and related hardware conforming to IS 14845 / C512, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Commonl Header

-

-

-

... More
Tedi Baghiya FM Pump :- 100 mm

1

41571

41571.3

... More
Etmadpur FM Pump :- 100 mm

1

41571

41571.3

... More
Transyamuna-I & II FM Pump :- 200 mm

1

63866

63866.24

... More
Supply of dismantling joints and related hardware, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Individual Header, mm

-

-

-

... More
Tedi Baghiya FM Pump :- 400 mm

4

254612

63653.23

... More
Etmadpur FM Pump :- 250 mm

4

131528

32882.07

... More
Transyamuna-I & II FM Pump :- 400 mm

5

318266

63653.23

... More
Commonl Header, mm

-

-

-

... More
Tedi Baghiya FM Pump :- 500 mm

1

92332

92332.69

... More
Etmadpur FM Pump :- 300 mm

1

37775

37775.52

... More
Transyamuna-I & II FM Pump :- 800 mm

1

135462

135462.21

... More
Providing and supplying ISI mark DI D/F reflux valves (non-returnvalves ) of following dia including all railway freight, inspection chargesunloding from railway wagon,loading into truck, transportation upto departmental stroes/ site,unloading, stacking etc. complete. Reflux valves as per I.S.5312 Part I(1984).

-

-

-

... More
Pumping Main

-

-

-

... More
Tedi Baghiya FM Pump :- 400 mm

4

1139886

284971.5

... More
Etmadpur FM Pump :- 250 mm

4

379962

94990.5

... More
Transyamuna-I & II FM Pump :- 400 mm

5

1424857

284971.5

... More
Providing, errecting, commissioning and testing of non clog sump pump set having pump discharge capacity of 30 LPS raw water with silt and mid at a total head of 30m with piping and other necessary arrangements.

-

-

-

... More
Q=30LPS, H=30m with suitable motor HP

3

680106

226702.2

... More
Providing, fabricating, testing, transporting, and handling mild steel pipes and bends as per IS 5504, IS 3589 and the specifications and drawings. The rate to include transportation of pipes to site, loading, unloading, storage, guarding, and issuance to works as per specifications. The rates shall be inclusive of Collecting materials from storage, loading, transporting, unloading, laying and jointing/ welding pipe connections to correct line and level as per the specifications and drawings. The rate to include hoisting, lowering, marginal cutting wherever necessary, assembling, providing supports, thrust blocks, anchor blocks etc., as per specifications and drawings. The rate also includes testing of field joints . The rate shall also inclusive of internal and external epoxy coating and lining for corrosion protections as specified in the Specifications.

-

-

-

... More
Indivisual Header, mm

-

-

-

... More
Tedi Baghiya FM Pump :- 400 mm

20

195738

9786.9

... More
Etmadpur FM Pump :- 250 mm

20

128573

6428.65

... More
Transyamuna-I & II FM Pump :- 400 mm

25

244672

9786.9

... More
Commonl Header, mm

-

-

-

... More
Tedi Baghiya FM Pump - 500 mm

10

146803

14680.35

... More
Etmadpur FM Pump - 300 mm

10

76760

7676

... More
Transyamuna-I & II FM Pump - 800 mm

10

275376

27537.65

... More
Supply and errection of new Electrical Operated Crane (EOT) with chain pulley block complete. 10 T and Above 8 m upto 10 m span

3

3160593

1053531

... More
Providing and supplying ISI mark Electromagnetic Flow meter of following dia including all railway freight, inspection charges unloading from railway wagon, loading into truck, transportation up to departmental stores / site, unloading, stacking etc. complete.

-

-

-

... More
On feeder Main

-

-

-

... More
Tedi Baghiya Feeder Main - 500 mm

1

527725

527725

... More
Etmadpur Feeder Main

-

-

-

... More
CWR WTP to Junction-1 (TY Zone-2) - 500 mm

1

527725

527725

... More
Junction-1 to Nauki Sarai Ex. CWR (TY Zone-2) - 350 mm

1

316635

316635

... More
Junction-1 to Junction-2 (TY Zone-2) - 400 mm

1

402990

402990

... More
Junction-2 to Chhalesar CWR (TY Zone-2) - 350 mm

1

316635

316635

... More
Junction-2 to Etmadpur CWR (Etmadpur Nagar Palika Parishad) - 300 mm

1

249470

249470

... More
Trans Yamuna-I&II Feeder Main

-

-

-

... More
CWR WTP to Junction-1 (TY Zone-2) - 1000 mm

1

1055450

1055450

... More
Junction-1 to Kalandi Vihar CWR (TY Zone-2) - 500 mm

1

527725

527725

... More
Junction-1 to Junction-2 (TY Zone-1) - 900 mm

1

949905

949905

... More
Junction-2 to Sita Nagar CWR (TY Zone-1) - 500 mm

1

527725

527725

... More
Junction-2 to Prakash Nagar CWR (TY Zone-1) - 700 mm

1

738815

738815

... More
Spetials, fittings,Pressure gauge, Saddle,Nuts Bolts washers etc, cost, Work includes making connection with existing pipes etc

-

-

-

... More
Tedi Baghiya FM Pump

1

23987

23987.5

... More
Etmadpur FM Pump

1

23987

23987.5

... More
Transyamuna-I & II FM Pump

1

23987

23987.5

... More
Clear Water Pumping Station Zone-1

-

-

-

... More
Providing, erecting, commissioning and giving test and trial of VT pump set , water lubricated type and having following duty point,operating speed including providing and fixing ISMB grating etc including Suppy and delivery of Vertical hollow /solid shaft squirrel gauge induction motor (IS 325) suitable for the above pumps continuous rated TEFC/ SPDP type with class F insulation for operation in AC 3-phase/ 50Hz (+/- 5%), 415 volt (+/- 10%)running with the speed of pump noted above and with inbuilt thrust bearing assembly capable of taking of the entire load and non reverse ratchet assembly etc complete. The motor rating noted above is the minimum and shall be such that it should never be overloaded when the pump works at the MWL condition and shall be 10% over and above the maximum HP absorbed by the pump. The motor offered should be energy efficient to have maximum efficiency at high powerfactor. Separate thrust bearing assembly could also be supplied to takeup the down load. 1500 RPM, as per detailed specifications.

-

-

-

... More
Shahdra RM PUMP - Q=72.4LPS H=52m with suitable motor HP

2

5330982

2665491

... More
Nawal Ganj RM PUMP - Q=135.7LPS H=49m with suitable motor HP

2

5639941

2819970.5

... More
Kacchpura RM PUMP - Q=77.7LPS H=46m with suitable motor HP

2

5760838

2880419

... More
Prakash Nagar RM PUMP - Q=69.7LPS H=43m with suitable motor HP

2

5457636

2728818

... More
Providing, erecting and commissioning of Booster Pump Horizontal Slit Casing Centrifugal Booster pump suted for variable frequency drive to regulate the discharge as per demand.

-

-

-

... More
Booster Pump SZ 1.5 DMA-2 - Q=23.3LPS H=7m with suitable motor HP

2

4665089

2332544.5

... More
Booster Pump SZ 1.5 - Q=107.3LPS H=10m with suitable motor HP

2

6035255

3017627.5

... More
Booster Pump SZ 1.6 DMA-4 - Q=39.1LPS H=5m with suitable motor HP

2

4536516

2268258

... More
Providing, erecting and commissioning of Booster Pump Horizontal Slit Casing Centrifugal Booster pump suted for variable frequency drive to regulate the discharge as per demand.

-

-

-

... More
Pumping Main

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 200 mm

2

293607

146803.5

... More
Shahdra RM PUMP - 250 mm

2

355015

177507.5

... More
Nawal Ganj RM PUMP - 350 mm

2

497021

248510.5

... More
Kacchpura RM PUMP - 250 mm

2

355015

177507.5

... More
Prakash Nagar RM PUMP - 250 mm

2

355015

177507.5

... More
On Delivery Pipe of Booster Pump

-

-

-

... More
Booster Pump SZ 1.5 DMA-2 - 200 mm

2

293607

146803.5

... More
Booster Pump SZ 1.5 - 400 mm

2

544996

272498

... More
Booster Pump SZ 1.6 DMA-4 - 200 mm

2

293607

146803.5

... More
Supply of double flanged,DI, short body sluice valves with electrical actator and related hardware conforming to IS 14846, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications . Commonl Header, mm

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 300 mm

1

206292

206292.5

... More
Shahdra RM PUMP - 350 mm

1

287850

287850

... More
Nawal Ganj RM PUMP - 400 mm

1

326230

326230

... More
Kacchpura RM PUMP -350 mm

1

287850

287850

... More
Prakash Nagar RM PUMP -250 mm

1

182305

182305

... More
On Suction, Delivery Side & Main Pipe of Booster Pump.

-

-

-

... More
Booster Pump SZ 1.1 DMA-1 - 350 mm

1

287850

287850

... More
Booster Pump SZ 1.1 DMA-2 -300 mm

1

206292

206292.5

... More
Booster Pump SZ 1.1 DMA-3 - 350 mm

1

287850

287850

... More
Booster Pump SZ 1.5 DMA-2 - 200 mm

3

431775

143925

... More
Booster Pump SZ 1.5 - 400 mm

3

978690

326230

... More
Booster Pump SZ 1.6 DMA-4 - 200 mm

3

431775

143925

... More
Booster Pump SZ 1.8 DMA-3 - 200 mm

1

143925

143925

... More
Supply of flanged DI Kinetic air valve including isolated sluice valve and related hardware conforming to IS 14845 / C512, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications . Common Header

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 100 mm

1

41571

41571.3

... More
Shahdra RM PUMP - 100 mm

1

41571

41571.3

... More
Nawal Ganj RM PUMP - 100 mm

1

41571

41571.3

... More
Kacchpura RM PUMP - 100 mm

1

41571

41571.3

... More
Prakash Nagar RM PUMP - 80 mm

1

35530

35530.29

... More
On Delivery Pipe of Booster Pump

-

-

-

... More
Booster Pump SZ 1.5 DMA-2 - 80 mm

2

71060

35530.29

... More
Booster Pump SZ 1.5 -100 mm

2

83142

41571.3

... More
Booster Pump SZ 1.6 DMA-4 -80 mm

2

71060

35530.29

... More
Supply of dismantling joints and related hardware, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Individual Header, mm

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 200 mm

2

45250

22625.01

... More
Shahdra RM PUMP -250 mm

2

65764

32882.07

... More
Nawal Ganj RM PUMP -350 mm

2

99807

49903.6

... More
Kacchpura RM PUMP -250 mm

2

65764

32882.07

... More
Prakash Nagar RM PUMP -250 mm

2

65764

32882.07

... More
Commonl Header, mm

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) -300 mm

1

37775

37775.52

... More
Shahdra RM PUMP -350 mm

1

49903

49903.6

... More
Nawal Ganj RM PUMP - 400 mm

1

63653

63653.23

... More
Kacchpura RM PUMP - 350 mm

1

49903

49903.6

... More
Prakash Nagar RM PUMP - 250 mm

1

32882

32882.07

... More
Suction & Delivery Pipes of Booster Pumps,mm

-

-

-

... More
Booster Pump SZ 1.1 DMA-1 - 350 mm

1

49903

49903.6

... More
Booster Pump SZ 1.1 DMA-2 - 300 mm

1

37775

37775.52

... More
Booster Pump SZ 1.1 DMA-3 -350 mm

1

49903

49903.6

... More
Booster Pump SZ 1.5 DMA-2 - 200 mm

3

113326

37775.52

... More
Booster Pump SZ 1.5 - 400 mm

3

190959

63653.23

... More
Booster Pump SZ 1.6 DMA-4 - 200 mm

3

67875

22625.01

... More
Booster Pump SZ 1.8 DMA-3 - 200 mm

1

22625

22625.01

... More
Providing and supplying ISI mark DI D/F reflux valves (non-returnvalves ) of following dia including all railway freight, inspection chargesunloding from railway wagon,loading into truck, transportation upto departmental stroes/ site,unloading, stacking etc. complete. Reflux valves as per I.S.5312 Part I(1984).

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 200 mm

2

107464

53732

... More
Shahdra RM PUMP - 250 mm

2

189981

94990.5

... More
Nawal Ganj RM PUMP - 350 mm

2

435613

217806.5

... More
Kacchpura RM PUMP - 250 mm

2

189981

94990.5

... More
Prakash Nagar RM PUMP - 250 mm

2

189981

94990.5

... More
On Delivery Pipe of Booster Pump

-

-

-

... More
Booster Pump SZ 1.5 DMA-2 - 200 mm

2

107464

53732

... More
Booster Pump SZ 1.5 - 400 mm

2

569943

284971.5

... More
Booster Pump SZ 1.6 DMA-4 - 200 mm

2

107464

53732

... More
Providing, errecting, commissioning and testing of non clog sump pump set having pump discharge capacity of 30 LPS raw water with silt and mid at a total head of 30m with piping and other necessary arrangements. Q=30LPS, H=30m with suitable motor HP

5

1133511

226702.2

... More
Providing, fabricating, testing, transporting, and handling mild steel pipes and bends as per IS 5504, IS 3589 and the specifications and drawings. The rate to include transportation of pipes to site, loading, unloading, storage, guarding, and issuance to works as per specifications. The rates shall be inclusive of Collecting materials from storage, loading, transporting, unloading, laying and jointing/ welding pipe connections to correct line and level as per the specifications and drawings. The rate to include hoisting, lowering, marginal cutting wherever necessary, assembling, providing supports, thrust blocks, anchor blocks etc., as per specifications and drawings. The rate also includes testing of field joints . The rate shall also inclusive of internal and external epoxy coating and lining for corrosion protections as specified in the Specifications.

-

-

-

... More
Indivisual Header, mm

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) - 200 mm

10

53732

5373.2

... More
Shahdra RM PUMP - 250 mm

10

64286

6428.65

... More
Nawal Ganj RM PUMP - 350 mm

10

87314

8731.45

... More
Kacchpura RM PUMP - 250 mm

12

77143

6428.65

... More
Prakash Nagar RM PUMP - 250 mm

14

90001

6428.65

... More
Commonl Header, mm

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised) -300 mm

10

76760

7676

... More
Shahdra RM PUMP - 350 mm

10

87314

8731.45

... More
Nawal Ganj RM PUMP - 400 mm

10

97869

9786.9

... More
Kacchpura RM PUMP - 350 mm

10

87314

8731.45

... More
Prakash Nagar RM PUMP - 250 mm

10

64286

6428.65

... More
Booster Pump Suction & Delivery Pipe

-

-

-

... More
Booster Pump SZ 1.1 DMA-1 - 350 mm

10

87314

8731.45

... More
Booster Pump SZ 1.1 DMA-2 - 300 mm

10

76760

7676

... More
Booster Pump SZ 1.1 DMA-3 - 350 mm

10

87314

8731.45

... More
Booster Pump SZ 1.5 DMA-2 - 200 mm

10

53732

5373.2

... More
Booster Pump SZ 1.5 - 400 mm

10

97869

9786.9

... More
Booster Pump SZ 1.6 DMA-4 - 200 mm

10

53732

5373.2

... More
Booster Pump SZ 1.8 DMA-3 - 200 mm

10

53732

5373.2

... More
Supply and errection of new Electrical Operated Crane (EOT) with chain pulley block complete. 5T and Above 8 m upto 10 m span

3

2383398

794466

... More
Providing and supplying ISI mark Electromagnetic Flow meter of following dia including all railway freight, inspection charges unloading from railway wagon, loading into truck, transportation up to departmental stores / site, unloading, stacking etc. complete.

-

-

-

... More
Rising Main

-

-

-

... More
Shahdra (SZ : 1.2 & 1.3) - 350 mm

1

316635

316635

... More
200 mm

1

182305

182305

... More
Nawal Ganj (SZ : 1.4, 1.5 & 1.8) - 500 mm

1

527725

527725

... More
300 mm

1

249470

249470

... More
300 mm

1

249470

249470

... More
300 mm

1

249470

249470

... More
Kacchpura (SZ : 1.6) -350 mm

1

316635

316635

... More
Prakash Nagar (SZ : 1.7) -300 mm

1

249470

249470

... More
OHT Outlet pipe

-

-

-

... More
Sita Nagar - 350 mm

1

316635

316635

... More
350 mm

1

316635

316635

... More
300 mm

1

249470

249470

... More
Shahdra-I - 250

1

215887

215887.5

... More
250 mm

1

215887

215887.5

... More
Shahdra-II - 300 mm

1

249470

249470

... More
Ex-Nawal Ganj-I - 300 mm

1

249470

249470

... More
250 mm

1

215887

215887.5

... More
Nawal Ganj-II - 400 mm

1

402990

402990

... More
Kachhpura - 500 mm

1

527725

527725

... More
Prakash Nagar - 400 mm

1

402990

402990

... More
Etmadaulah - 300 mm

1

249470

249470

... More
500 mm

1

527725

527725

... More
Spetials, fittings,Pressure gauge, Saddle,Nuts Bolts washers etc, cost, Work includes making connection with existing pipes etc

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised)

1

23987

23987.5

... More
Shahdra RM PUMP

1

23987

23987.5

... More
Nawal Ganj RM PUMP

1

23987

23987.5

... More
Kacchpura RM PUMP

1

23987

23987.5

... More
Prakash Nagar RM PUMP

1

23987

23987.5

... More
Providing, erecting and commissioning of Booster Pump set Horizontal Slit Casing Centrifugal Booster pump suted for variable frequency drive to regulate the discharge as per demand.

-

-

-

... More
Booster Pump SZ 1.1 DMA-1

1

14392

14392.5

... More
Booster Pump SZ 1.1 DMA-2

1

14392

14392.5

... More
Booster Pump SZ 1.1 DMA-3

1

14392

14392.5

... More
Booster Pump SZ 1.5 DMA-2

1

14392

14392.5

... More
Booster Pump SZ 1.5

1

14392

14392.5

... More
Booster Pump SZ 1.6 DMA-4

1

14392

14392.5

... More
Booster Pump SZ 1.8 DMA-3

1

14392

14392.5

... More
SITC of HYpochloride dosing system -2 tanks of 1500 lt ,Diaphragm pump- 2 no,VFD , Control panel with scada automation

-

-

-

... More
Sita Nagar RM PUMP (Ex Pumps of duty 3600LPM/37m of 9VT Utilised)

1

741367

741367.27

... More
Shahdra RM PUMP

1

741367

741367.27

... More
Nawal Ganj RM PUMP

1

741367

741367.27

... More
Kacchpura RM PUMP

1

741367

741367.27

... More
Prakash Nagar RM PUMP

1

741367

741367.27

... More
Designing, supplying, installing, commissioning and testing of pilot operated hydraulically controlled Flow limiting cum Altitute Control Valve for ESR Inlet with level controlling and flow limiting application which maintains aconstant downstream rate of flow. Also, closes on high reservoir level (FSL). opens when reservoir level drops with fixed set points inclusive of all accessories like integral Float arrrangement pressure gauge etc. complete as per specification.

-

-

-

... More
Shahdra (SZ : 1.2 & 1.3) - 200 mm

1

219196

219196.43

... More
200 mm

1

219196

219196.43

... More
300 mm

1

384937

384937.58

... More
300 mm

1

384937

384937.58

... More
350 mm

1

560894

560894.53

... More
Nawal Ganj (SZ : 1.4, 1.5 & 1.8) - 300 mm

1

384937

384937.58

... More
Clear Water Pumping Station Zone-2

-

-

-

... More
Providing, erecting, commissioning and giving test and trial of VT pump set , water lubricated type and having following duty point,operating speed including providing and fixing ISMB grating etc including Suppy and delivery of Vertical hollow /solid shaft squirrel gauge induction motor (IS 325) suitable for the above pumps continuous rated TEFC/ SPDP type with class F insulation for operation in AC 3-phase/ 50Hz (+/- 5%), 415 volt (+/- 10%)running with the speed of pump noted above and with inbuilt thrust bearing assembly capable of taking of the entire load and non reverse ratchet assembly etc complete. The motor rating noted above is the minimum and shall be such that it should never be overloaded when the pump works at the MWL condition and shall be 10% over and above the maximum HP absorbed by the pump. The motor offered should be energy efficient to have maximum efficiency at high powerfactor. Separate thrust bearing assembly could also be supplied to takeup the down load. 1500 RPM, as per detailed specifications.

-

-

-

... More
Bhagwati Bagh RM PUMP - Q=68.7LPS H=46m with suitable motor HP

2

5171705

2585852.5

... More
Tedi Baghiya RM PUMP - Q=89.2LPS H=46m with suitable motor HP

2

5822246

2911123

... More
Chhalesar RM PUMP - Q=14.4LPS H=42m with suitable motor HP

2

5870221

2935110.5

... More
Nagla RM PUMP - Q=147.1LPS H=47m with suitable motor HP

2

5820327

2910163.5

... More
Nauki Sarai RM PUMP - Q=40.4LPS H=46m with suitable motor HP

2

447127

223563.5

... More
Kalandi Vihar RM PUMP - Q=45LPS H=43m with suitable motor HP

2

4903045

2451522.5

... More
Supply of double flanged DI short body pattern butterfly valve with electrical actuator with intregal starter and related hardware, including chair support, etc., conforming to IS 13095/BS EN 593, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 200 mm

2

293607

146803.5

... More
Bhagwati Bagh RM PUMP - 250 mm

2

355015

177507.5

... More
Tedi Baghiya RM PUMP - 300 mm

2

379962

189981

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 250 mm

3

532522

177507.5

... More
Chhalesar RM PUMP - 150 mm

2

245632

122816

... More
Nagla RM PUMP - 350 mm

2

497021

248510.5

... More
Nauki Sarai RM PUMP - 250 mm

2

355015

177507.5

... More
Kalandi Vihar RM PUMP - 250 mm

2

355015

177507.5

... More
Supply of double flanged,DI, short body sluice valves with electrical actuator with intregal starter and related hardware conforming to IS 14846, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Commonl Header, mm

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 250 mm

1

182305

182305

... More
Bhagwati Bagh RM PUMP - 300 mm

1

206292

206292.5

... More
Tedi Baghiya RM PUMP - 350 mm

1

287850

287850

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 350 mm

1

287850

287850

... More
Chhalesar RM PUMP - 150 mm

1

119937

119937.5

... More
Nagla RM PUMP -500 mm

1

450965

450965

... More
Nauki Sarai RM PUMP - 350 mm

1

287850

287850

... More
Kalandi Vihar RM PUMP -250 mm

1

182305

182305

... More
Commonl Header, mm

-

-

-

... More
Booster Pump SZ 2.5 DMA-1 - 200 mm

1

143925

143925

... More
Booster Pump SZ 2.5 DMA-4 - 350 mm

1

287850

287850

... More
Booster Pump SZ 2.5 DMA-3 - 300 mm

1

206292

206292.5

... More
Booster Pump SZ 2.5 DMA-2 -200 mm

1

143925

143925

... More
Booster Pump SZ 2.1 DMA-1&2 - 400 mm

1

326230

326230

... More
Booster Pump SZ 2.1 DMA-3 - 250 mm

1

182305

182305

... More
Supply of flanged DI Kinetic air valve including isolated sluice valve and related hardware conforming to IS 14845 / C512, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications . Common Header

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 80 mm

1

35530

35530.29

... More
Bhagwati Bagh RM PUMP - 100 mm

1

41571

41571.3

... More
Tedi Baghiya RM PUMP - 100 mm

1

41571

41571.3

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 100 mm

1

41571

41571.3

... More
Chhalesar RM PUMP - 80 mm

1

35530

35530.29

... More
Nagla RM PUMP - 100 mm

1

41571

41571.3

... More
Nauki Sarai RM PUMP - 100 mm

1

41571

41571.3

... More
Kalandi Vihar RM PUMP - 80 mm

1

35530

35530.29

... More
Supply of dismantling joints and related hardware, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .

-

-

-

... More
Individual Header, mm

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 200 mm

2

45250

22625.01

... More
Bhagwati Bagh RM PUMP -250 mm

2

65764

32882.07

... More
Tedi Baghiya RM PUMP - 300 mm

2

75551

37775.52

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized -250 mm

3

98646

32882.07

... More
Chhalesar RM PUMP -150 mm

2

32661

16330.69

... More
Nagla RM PUMP - 350 mm

2

99807

49903.6

... More
Nauki Sarai RM PUMP - 250 mm

2

65764

32882.07

... More
Kalandi Vihar RM PUMP - 250 mm

2

65764

32882.07

... More
Commonl Header, mm

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 250 mm

1

32882

32882.07

... More
Bhagwati Bagh RM PUMP - 300 mm

1

37775

37775.52

... More
Tedi Baghiya RM PUMP - 350 mm

1

49903

49903.6

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 350 mm

1

49903

49903.6

... More
Chhalesar RM PUMP - 150 mm

1

16330

16330.69

... More
Nagla RM PUMP - 500 mm

1

92332

92332.69

... More
Nauki Sarai RM PUMP - 350 mm

1

49903

49903.6

... More
Kalandi Vihar RM PUMP - 250 mm

1

32882

32882.07

... More
Suction & Delivery Pipes of Booster Pumps,mm

-

-

-

... More
Booster Pump SZ 2.5 DMA-1 - 200 mm

1

22625

22625.01

... More
Booster Pump SZ 2.5 DMA-4 - 350 mm

1

49903

49903.6

... More
Booster Pump SZ 2.5 DMA-3 - 300 mm

1

37775

37775.52

... More
Booster Pump SZ 2.5 DMA-2 - 200 mm

1

22625

22625.01

... More
Booster Pump SZ 2.1 DMA-1&2 - 400 mm

1

63653

63653.23

... More
Booster Pump SZ 2.1 DMA-3 - 250 mm

1

32882

32882.07

... More
Providing and supplying ISI mark DI D/F reflux valves (non-returnvalves) of following dia including all railway freight, inspection chargesunloding from railway wagon,loading into truck, transportation upto departmental stroes/ site,unloading, stacking etc. complete. Reflux valves as per I.S.5312 Part I(1984).

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 200 mm

2

107464

53732

... More
Bhagwati Bagh RM PUMP - 250 mm

2

189981

94990.5

... More
Tedi Baghiya RM PUMP - 300 mm

2

274417

137208.5

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 250 mm

3

284971

94990.5

... More
Chhalesar RM PUMP - 150 mm

2

82517

41258.5

... More
Nagla RM PUMP - 350 mm

2

435613

217806.5

... More
Nauki Sarai RM PUMP - 250 mm

2

189981

94990.5

... More
Kalandi Vihar RM PUMP - 250 mm

2

189981

94990.5

... More
Providing, errecting, commissioning and testing of non clog sump pump set having pump discharge capacity of 30 LPS raw water with silt and mid at a total head of 30m with piping and other necessary arrangements.

-

-

-

... More
Q=30LPS, H=30m with suitable motor HP

5

1133511

226702.2

... More
Providing, fabricating, testing, transporting, and handling mild steel pipes and bends as per IS 5504, IS 3589 and the specifications and drawings. The rate to include transportation of pipes to site, loading, unloading, storage, guarding, and issuance to works as per specifications. The rates shall be inclusive of Collecting materials from storage, loading, transporting, unloading, laying and jointing/ welding pipe connections to correct line and level as per the specifications and drawings. The rate to include hoisting, lowering, marginal cutting wherever necessary, assembling, providing supports, thrust blocks, anchor blocks etc., as per specifications and drawings. The rate also includes testing of field joints . The rate shall also inclusive of internal and external epoxy coating and lining for corrosion protections as specified in the Specifications.

-

-

-

... More
Indivisual Header, mm

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 200 mm

10

53732

5373.2

... More
Bhagwati Bagh RM PUMP - 250 mm

10

64286

6428.65

... More
Tedi Baghiya RM PUMP - 300 mm

10

76760

7676

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 250 mm

18

157166

8731.45

... More
Chhalesar RM PUMP - 150 mm

14

60448

4317.75

... More
Nagla RM PUMP - 350 mm

16

139703

8731.45

... More
Nauki Sarai RM PUMP - 250 mm

18

115715

6428.65

... More
Kalandi Vihar RM PUMP - 250 mm

20

128573

6428.65

... More
Commonl Header, mm

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised) - 250 mm

10

64286

6428.65

... More
Bhagwati Bagh RM PUMP - 300 mm

10

76760

7676

... More
Tedi Baghiya RM PUMP - 350 mm

10

87314

8731.45

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized - 350 mm

10

87314

8731.45

... More
Chhalesar RM PUMP - 150 mm

10

43177

4317.75

... More
Nagla RM PUMP - 500 mm

10

146803

14680.35

... More
Nauki Sarai RM PUMP - 350 mm

10

87314

8731.45

... More
Kalandi Vihar RM PUMP - 250 mm

10

64286

6428.65

... More
Supply and errection of new Electrical Operated Crane (EOT) with chain pulley block complete. 5 T and Above 8 m upto 10 m span

3

2383398

794466

... More
Providing and supplying ISI mark Electromagnetic Flow meter of following dia including all railway freight, inspection charges unloading from railway wagon, loading into truck, transportation up to departmental stores / site, unloading, stacking etc. complete. Rising mains

-

-

-

... More
Nauki Sarai (SZ: 2.6) - 250 mm

1

215887

215887.5

... More
Ravi Nagar (SZ : 2.7) - 250 mm

1

215887

215887.5

... More
Bhagwati Bagh : (SZ : 2.8 ) - 300 mm

1

249470

249470

... More
Tedi Baghiya (SZ : 2.9) -350 mm

1

316635

316635

... More
Kalandi Vihar-2 (SZ : 2.10) - 250 mm

1

215887

215887.5

... More
Chhalesar (SZ : 2.11) - 150 mm

1

143925

143925

... More
Nagla Rising Main (SZ : 2.1, 2.3 & 2.4) - 500 mm

1

738815

738815

... More
300 mm

1

633270

633270

... More
Nagla Rising Main (SZ : 2.1, 2.3 & 2.4) - 500 mm

1

527725

527725

... More
300 mm

1

249470

249470

... More
OHT Outlet pipe

-

-

-

... More
Transyamuna Ph-1 - 250 mm

1

215887

215887.5

... More
400 mm

1

402990

402990

... More
Naraich - 500 mm

1

527725

527725

... More
Nagla Jamuni - 400 mm

1

402990

402990

... More
Nagla Rambal - 250 mm

1

215887

215887.5

... More
300 mm

1

249470

249470

... More
250 mm

1

215887

215887.5

... More
Kalandi Vihar-I - 350 mm

1

316635

316635

... More
200 mm

1

182305

182305

... More
300 mm

1

249470

249470

... More
200 mm

1

182305

182305

... More
Nauki Sarai - 450 mm

1

479750

479750

... More
Ravinagar - 500

1

527725

527725

... More
Bhagwati Bagh - 200 mm

1

182305

182305

... More
300 mm

1

249470

249470

... More
400 mm

1

402990

402990

... More
Tedi Baghiya - 350 mm

1

316635

316635

... More
300 mm

1

249470

249470

... More
350 mm

1

316635

316635

... More
Kalandi Vihar-II - 400 mm

1

402990

402990

... More
250 mm

1

215887

215887.5

... More
Chhaleshar - 250 mm

1

215887

215887.5

... More
Spetials, fittings,Pressure gauge, Saddle,Nuts Bolts washers etc, cost, Work includes making connection with existing pipes etc

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised)

1

23987

23987.5

... More
Bhagwati Bagh RM PUMP

1

23987

23987.5

... More
Tedi Baghiya RM PUMP

1

23987

23987.5

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized

1

23987

23987.5

... More
Chhalesar RM PUMP

1

23987

23987.5

... More
Nagla RM PUMP

1

23987

23987.5

... More
Nauki Sarai RM PUMP

1

23987

23987.5

... More
Kalandi Vihar RM PUMP

1

23987

23987.5

... More
Booster Pump

-

-

-

... More
Booster Pump SZ 2.5 DMA-1

1

14392

14392.5

... More
Booster Pump SZ 2.5 DMA-4

1

14392

14392.5

... More
Booster Pump SZ 2.5 DMA-3

1

14392

14392.5

... More
Booster Pump SZ 2.5 DMA-2

1

14392

14392.5

... More
Booster Pump SZ 2.1 DMA-1&2

1

14392

14392.5

... More
Booster Pump SZ 2.1 DMA-3

1

14392

14392.5

... More
SITC of HYpochloride dosing system -2 tanks of 1500 lt ,Diaphragm pump- 2 no,VFD , Control panel with scada automation

-

-

-

... More
Ravi Nagar RM PUMP(Ex Pumps of duty 1950LPM/47m of 9VT Utilised)

1

741367

741367.27

... More
Bhagwati Bagh RM PUMP

1

741367

741367.27

... More
Tedi Baghiya RM PUMP

1

741367

741367.27

... More
Ex. GW Rising Main Nauki Sarai PUMPExisting pumps are utilized

1

741367

741367.27

... More
Chhalesar RM PUMP

1

741367

741367.27

... More
Nagla RM PUMP

1

741368

741368.23

... More
Nauki Sarai RM PUMP

1

741369

741369.19

... More
Kalandi Vihar RM PUMP

1

741370

741370.15

... More
Designing, supplying, installing, commissioning and testing of pilot operated hydraulically controlled Flow limiting cum Altitute Control Valve for ESR Inlet with level controlling and flow limiting application which maintains aconstant downstream rate of flow. Also, closes on high reservoir level (FSL). opens when reservoir level drops with fixed set points inclusive of all accessories like integral Float arrrangement pressure gauge etc. complete as per specification.

-

-

-

... More
Nauki Sarai (SZ: 2.6) - 250 mm

1

286074

286074.54

... More
Ravi Nagar (SZ : 2.7) - 300 mm

1

384937

384937.58

... More
Bhagwati Bagh : (SZ : 2.8 ) - 350 mm

1

560894

560894.53

... More
Tedi Baghiya (SZ : 2.9) - 700 mm

1

1778902

1778902.64

... More
Kalandi Vihar-2 (SZ : 2.10) - 150 mm

1

168311

168311.27

... More
Chhalesar (SZ : 2.11) - 500 mm

1

1322189

1322189.66

... More
Nagla Rising Main (SZ : 2.1, 2.3 & 2.4) - 700 mm

1

1778902

1778902.64

... More
500 mm

1

1322189

1322189.66

... More
E&I Works for Transyamuna Raw Water Pumping Station

-

-

-

... More
Electrical System

-

-

-

... More
Design, Supply, Installation, Testing and Commissioning of oil immersed Outdoor type Power distribution transformer 33/0.433 KV rating 1000 KVA double wound with copper winding, ONAN with onload tap changer operated for voltage variation + 10.0 % to - 10% in step of 1.25%with their RTCC panel alongwith marshalling box, WTI, OTI, Buchholz relay etc conforming to releavent Indian Standards complete with standard fitting & accessories complete in all respect at B-1, Trans Yamuna CWR Pumping Station

2

3356453

1678226.52

... More
Design, Supply, Installation, Testing and Commissioning of 33 kV indoor HT Panel as per approved single line diagram at Both pumping Stations

1

3295874

3295874.15

... More
Design, Supply, Installation, Testing and Commissioning of 110V Ni-Cd battery, battery charger & DC distribution board and accessories

1

301267

301267.55

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, Indoor Switch board PMCC panel (including 5 soft starters, Lighting and Power arrangements) at Pumping Station

1

2862833

2862833.19

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, APFC panel of suitable rating complete with required APFC relay and capacitor bank complete.

1

533530

533530.55

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - external lighting

1

88859

88859.3

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, utility sockets (3ph and 1ph.) and necessary accessories - internal lighting

1

137718

137718.95

... More
Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories

1

183775

183775.53

... More
Complete cabling system with HV Power cables, cable trays, route marker, steel structure for cable trench, pipes and accessories

1

667270

667270.27

... More
Complete cabling system with LV power and control cables, cable trays, route marker, steel structure for cable trench, pipes and accessories

1

361323

361323.91

... More
Start stop Push Button Stations

5

10699

2139.88

... More
E&I Works for Transyamuna Raw Water Pumping Station

-

-

-

... More
Electrical System

-

-

-

... More
Design, Supply, Installation, Testing and Commissioning of oil immersed Outdoor type Power distribution transformer 33/0.433 KV rating 2500 KVA double wound with copper winding, ONAN with onload tap changer operated for voltage variation + 10.0 % to - 10% in step of 1.25%with their RTCC panel alongwith marshalling box, WTI, OTI, Buchholz relay etc conforming to releavent Indian Standards complete with standard fitting & accessories complete in all respect at B-1, Trans Yamuna CWR Pumping Station

2

10733926

5366963.25

... More
Design, Supply, Installation, Testing and Commissioning of 33 kV indoor HT Panel as per approved single line diagram at Both pumping Stations

1

3295874

3295874.15

... More
Design, Supply, Installation, Testing and Commissioning of 110V Ni-Cd battery, battery charger & DC distribution board and accessories

1

301267

301267.55

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, Indoor Switch board PMCC panel (including 13 soft starters, Lighting and Power arrangements) at Pumping Station

1

4292631

4292631.06

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, APFC panel of suitable rating complete with required APFC relay and capacitor bank complete.

1

549981

549981.18

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - external lighting

1

88859

88859.3

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, utility sockets (3ph and 1ph.) and necessary accessories - internal lighting

1

137718

137718.95

... More
Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories

1

183775

183775.53

... More
Complete cabling system with HV Power cables, cable trays, route marker, steel structure for cable trench, pipes and accessories

1

667270

667270.27

... More
Complete cabling system with LV power and control cables, cable trays, route marker, steel structure for cable trench, pipes and accessories

1

361323

361323.91

... More
Start stop Push Button Stations

13

27818

2139.88

... More
Electrical & Instrumentation Works for the Zonal Pumping Station

-

-

-

... More
Electrical System

-

-

-

... More
Design, Supply, Installation, Testing and Commissioning of oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 400 KVA double wound with copper winding, ONAN with onload tap changer operated for voltage variation + 10.0 % to - 10% in step of 1.25%with their RTCC panel alongwith marshalling box, WTI, OTI, Buchholz relay etc conforming to releavent Indian Standards complete with standard fitting & accessories complete in all respect at B-1, 19.2 Tedi Bagiya Pumping Station

2

2136438

1068219.47

... More
Design, Supply, Installation, Testing and Commissioning of oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 160 KVA double wound with copper winding, ONAN with onload tap changer operated for voltage variation + 10.0 % to - 10% in step of 1.25%with their RTCC panel alongwith marshalling box, WTI, OTI, Buchholz relay etc conforming to releavent Indian Standards complete with standard fitting & accessories complete in all respect at B-1, 19.2 Nau ki Sarai Pumping Station

2

974879

487439.95

... More
Design, Supply, Installation, Testing and Commissioning of oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 400 KVA double wound with copper winding, ONAN with onload tap changer operated for voltage variation + 10.0 % to - 10% in step of 1.25%with their RTCC panel alongwith marshalling box, WTI, OTI, Buchholz relay etc conforming to releavent Indian Standards complete with standard fitting & accessories complete in all respect at B-1, 19.2 Kalindi ViharPumping Station

2

2136438

1068219.47

... More
Design, Supply, Installation, Testing and Commissioning of oil immersed Outdoor type Power distribution transformer 11/0.433 KV rating 250 KVA double wound with copper winding, ONAN with onload tap changer operated for voltage variation + 10.0 % to - 10% in step of 1.25%with their RTCC panel alongwith marshalling box, WTI, OTI, Buchholz relay etc conforming to releavent Indian Standards complete with standard fitting & accessories complete in all respect at B-1, 19.2 Prakash NagarPumping Station

2

1296382

648191.42

... More
SITC of 11kV indoor HT VCB Panel as per approved single line diagram at Tedi Bagiya Pumping Station

1

1453188

1453188.43

... More
SITC of 11kV indoor HT VCB Panel as per approved single line diagram at Nau ki Sarai Pumping Station

1

1453188

1453188.43

... More
SITC of 11kV indoor HT VCB Panel as per approved single line diagram at Kalindi ViharPumping Station

1

1453188

1453188.43

... More
SITC of 11kV indoor HT VCB Panel as per approved single line diagram at Prakash Nagar Pumping Station

1

1453188

1453188.43

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, Indoor Switch board PMCC panel (including 6 soft starters, Lighting and Power arrangements) at Tedi Bagiya Pumping Station

1

1917087

1917087.91

... More
SITC of 415 V, Indoor Switch board PMCC panel (including 2 soft starters, Lighting and Power arrangements) at Nau ki Sarai Pumping Station

1

711808

711808.72

... More
SITC of 415 V, Indoor Switch board PMCC panel (including 2 soft starters, Lighting and Power arrangements) at Chhalesar Pumping Station

1

578524

578524.1

... More
SITC of 415 V, Indoor Switch board PMCC panel (including 5 soft starters, Lighting and Power arrangements) at Kalindi Vihar Pumping Station

1

2237540

2237540.95

... More
SITC of 415 V, Indoor Switch board PMCC panel (including 6 soft starters, Lighting and Power arrangements) at Sita Nagar Pumping Station

1

2342916

2342916.5

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, Indoor Switch board PMCC panel (including 3 soft starters, Lighting and Power arrangements) at Prakash Nagar Pumping Station

1

1664670

1664670.52

... More
SITC of 415 V, APFC panel at Tedi Bagiya CWR Pumping Station

1

484085

484085.41

... More
SITC of 415 V, APFC panel at Nau KI Sarai Pumping Station

1

462502

462502.7

... More
SITC of 415 V, APFC panel at Chhalesar Pumping Station

1

447606

447606.46

... More
SITC of 415 V, APFC panel at Kalindi Vihar Pumping Station

1

484847

484847.06

... More
SITC of 415 V, APFC panel at Sita Nagar Pumping Station

1

514639

514639.53

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, APFC panel at Pra Kash Nagar Pumping Station

1

459228

459228.12

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - external lighting

6

533155

88859.3

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, utility sockets (3ph and 1ph.) and necessary accessories - internal lighting

6

826313

137718.95

... More
Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories

6

1102653

183775.53

... More
Complete cabling system with HV Power cables, cable trays, route marker, steel structure for cable trench, pipes and accessories

6

400362

66727.03

... More
Complete cabling system with LV power and control cables, cable trays, route marker, steel structure for cable trench, pipes and accessories

6

1194041

199007

... More
Start stop Push Button Stations

27

57776

2139.88

... More
AUTOMATION WORKS: Installation of Instrumentation and Control Equipment including, but not limited to, safe storage, protection, civil works, erection, installation, testing and commissioning required to complete the Works in all respects for the following equipment: Transyamuna Raw Water Pumping Station

-

-

-

... More
CE & UL approved manufacturer's RTU/PLC suitable to communicate with GSM based modem unit with CPU and power supply with analog and digital parameter and features as specified for each tubewell & CWR to store and transmit data on GSM backbone. RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification sheet including Control panel with IP 54 protection industrial grade for all equipments (Separate for control (24 V) and power equipments) with CE / UL approved manufacturer’s Surge protector for Control Panel and CE / UL approved manufacturer’s 7" HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters as specified in tender technical specification sheet .

1

495041

495041.32

... More
GSM/GPRS based wireless communicationmodem for RTU/PLC capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant as specified in tender technical specification sheet.

1

27002

27002.25

... More
CE / UL Certified 3 KVA UPS with batteries as per specification mentioned in technical bid documents.

1

135011

135011.27

... More
CE/UL approved manufacturer's Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. as per spec mentioned in technical bid documents.

1

22501

22501.88

... More
CE / UL approved manufacturer’s Radar type Level Transmitter for CWR as specified in tender technical specification sheet

1

108009

108009.02

... More
CE / UL approved manufacturer’s Pressure Transmitter in indivisual delivery line as well main header line of Pump as per specifications specified in tender technical specification sheet.

1

45003

45003.76

... More
CE/UL surge protector for control panel

1

13501

13501.13

... More
CE/UL Certified 7" HMI Touchscreen suitable to commuticate with PLC / RTU for loac display and control of process parameter.

1

27002

27002.25

... More
Complete control cable of all equipments at ZPS

1

72006

72006.01

... More
Control Panel with IP54 protection Indsutrial grade for all equipmets seprate for control (24 Volt) and power equipment.

1

135011

135011.27

... More
Complete instrumentation earthing system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories

1

46722

46722

... More
Security Surveillance IP Camera with Recorer

1

18001

18001.5

... More
Instaallation, Testing & Commissioning

1

18001

18001.5

... More
Trial Run for 3 Month

1

13501

13501.13

... More
AUTOMATION WORKS: Installation of Instrumentation and Control Equipment including, but not limited to, safe storage, protection, civil works, erection, installation, testing and commissioning required to complete the Works in all respects for the following equipment: Transyamuna Zonal Pumping Station

-

-

-

... More
CE & UL approved manufacturer's RTU/PLC suitable to communicate with GSM based modem unit with CPU and power supply with analog and digital parameter and features as specified for each tubewell & CWR to store and transmit data on GSM backbone. RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification sheet including Control panel with IP 54 protection industrial grade for all equipments (Separate for control (24 V) and power equipments) with CE / UL approved manufacturer’s Surge protector for Control Panel and CE / UL approved manufacturer’s 7" HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters as specified in tender technical specification sheet .

6

2970247

495041.32

... More
GSM/GPRS based wireless communicationmodem for RTU/PLC capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant as specified in tender technical specification sheet.

6

162013

27002.25

... More
CE / UL Certified 3 KVA UPS with batteries as per specification mentioned in technical bid documents.

6

810067

135011.27

... More
CE/UL approved manufacturer's Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. as per spec mentioned in technical bid documents.

6

135011

22501.88

... More
CE / UL approved manufacturer’s Radar type Level Transmitter for CWR as specified in tender technical specification sheet

6

648054

108009.02

... More
CE / UL approved manufacturer’s Pressure Transmitter in indivisual delivery line as well main header line of Pump as per specifications specified in tender technical specification sheet.

18

810067

45003.76

... More
CE/UL surge protector for control panel

6

81006

13501.13

... More
CE/UL Certified 7" HMI Touchscreen suitable to commuticate with PLC / RTU for loac display and control of process parameter.

6

162013

27002.25

... More
Complete control cable of all equipments at ZPS

6

432036

72006.01

... More
Control Panel with IP54 protection Indsutrial grade for all equipmets seprate for control (24 Volt) and power equipment.

6

810067

135011.27

... More
Complete instrumentation earthing system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories

6

280332

46722

... More
Security Surveillance IP Camera with Recorer

6

108009

18001.5

... More
Instaallation, Testing & Commissioning

6

108009

18001.5

... More
Trial Run for 3 Month

6

81006

13501.13

... More
Control cum Starting Panel for Booster Pumps with IP54 protection Indsutrial grade for all equipmets seprate for control (24 Volt) and power equipment.

6

810067

135011.27



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.