UP Jal Nigam Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

UP Jal Nigam - UPJN Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date7 Mar 2024
Closing Date8 Apr 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Performance-based Construction And Maintenance Contract For Bodla-i, Bodla-ii

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Reduction of UFW and Achievement of Performance Target: Reduce the performance parameters from the baseline levels to the Target level within the timeframe stipulated in the contract for the water supply and distribution system for 3 pilot zone. Refer the Technical Specification Section for a more detailed Description

1

-

-

... More
Capital Works-Bill-II

-

-

-

... More
Feeder main

-

-

-

... More
Excavation trenches in all kind of soil with required width of pipes including dewatering if required, shoring, excavation for sockets, and dressing of sides, ramming of bottoms, up to the required depth including removing the excavated soil, and then refilling the soil as required, in layers not exceeding 15 cm in depth including consolidating each deposited layer by ramming, watering etc and disposing of surplus excavated soil as directed, as per Technical Specifications and as per direction of Engineer. The work shall be inclusive of excavation without damaging the underground utilities like electrical and telephone cables, water distribution line, sewer and storm water lines and in case of damages the same shall be replaced with free of cost. The item is also inclusive of reinstatement of damaged sewer /water house service connections during excavation. The drains, public rams and other miscellaneous structures which get damaged while excavating shall be reinstated under this Item. The work is also inclusive of dismantling of Bituminous road,Cement Concrete road, interlocking tiles road sufaces for laying of pipeline and house connection work including sorting out of serviceable material and disposal of unserviceable materials.

-

-

-

... More
0 to 1.5 m depth

895.5

-

-

... More
Providing and supplying ISI mark DI-k9 S&S pipes (push on joints pressure pipes of D.I of following class and diameters confirming to the I.S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality) including all statutary duties and taxes , Third party inspection charges, including Transit insurance, Railway Freight, Unloading from railway wagon, Loading into Truck, Transportation to departmental store / site of work, unloading, stacking etc. completed as directed by Engineer –in-charge (IS 1536 / 2001 for pipes and IS 158 / 1969 and IS 12820 / 1989 or latest edition / revision with amendments for Rubber Gaskets.

-

-

-

... More
200 mm

800

-

-

... More
250 mm

120

-

-

... More
Lowering laying and jointing with SBR ruber gaskets D.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment as directed by Engineer in-charge including conveyance of material from stores to site of work, including cost of jointing materials and rubber rings labour, giving hydraulic testing etc. complete. Note : Only SBR Rubber gaskets to be used as per IS-5382 and IS- 12820.

-

-

-

... More
200 mm

800

-

-

... More
250 mm

120

-

-

... More
Providing, lowering & Laying double flanged Ductile Iron Sluice valves as per specifications including DI tail pieces with EPDM fully covered wedge and epoxy coating internal and external etc complete.

-

-

-

... More
Scour valve 100 mm

2

-

-

... More
200 mm

2

-

-

... More
250 mm

2

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing in pipe line Kinetic Double Air Valves as per IS:14845 of following dia including jointing and jointing specials, all material, labour, testing and commissioning as per technical Specifications and as per direction of Engineer-in- charge.

-

-

-

2

-

-

... More
Supply and Installation of Full bore Electromagnetic flowmeter including pressure transiducers, RTU , fittings to facilitate the installation with battery power for installation in remote places as specified in the specification of employers requirements.

-

-

-

... More
200 mm

1

-

-

... More
250 mm

1

-

-

... More
Providing erecting and commissioning MS dismantling joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia.

-

-

-

... More
100 mm

2

-

-

... More
200 mm

3

-

-

... More
250 mm

3

-

-

... More
Re-instatement of following type of road surfaces after laying of pipe line and house connection work including supply of all materials, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement.

-

-

-

... More
Bituminious Road

559.5

-

-

... More
Cement Concrete Road

115.8

-

-

... More
Interlocking Tiles Road

289.4

-

-

... More
Providing, laying & construction of RCC work of 1:2:4 in thurst block/ casing of pipe line as required during the construction period for laying of pipe lines as directed by Engineer-in-charge including normal form work, compacting, finishing the formed suffaces with CM 1:3 of sufficient minimum thickness to give a smooth and even sugace wherever necessary for proper completion of the work.

6

-

-

... More
Providing and fixing in position steel bar reinforcement required for item no. 27 including cutting bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete (including cost of binding wire and MS Bar)

0.24

-

-

... More
Dismantling of existing Ppipeline of MS/R.C.C/ C.I/P.S.C Pipe excluding the cost of excavation and refilling of trenches and stacking to the place as directed by Engineer in charge with all lead and lifts including the cleaning of surface etc. complete.

-

-

-

... More
100mm to 250 mm diameter

300

-

-

... More
300 mm to 500 mm diameter

150

-

-

... More
550 mm to 1200 mm diameter

50

-

-

... More
Providing and construction of RCC Chambers for following Feddermain Pipeline Appurtenancess with M-25 Cement Concrete as per Specification and as indicated in the drawing

-

-

-

... More
1. Sluice Valve Chambers

-

-

-

... More
100mm to 250 mm

4

-

-

... More
2. Flowmeter Valve Chambers

-

-

-

... More
100mm to 250 mm

2

-

-

... More
3. Air valve Chambers

-

-

-

2

-

-

... More
Scour Valve Chamber with 50m length of laying DN100 DI Pipe

-

-

-

... More
100 mm

2

-

-

... More
Disposal of surplus earth /unserviceable material, by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.

31.02

-

-

... More
Providing and erecting 2.0 metre high temporary barricading at site as per drawing direction of Engineer-in-charge which includes writing and painting, arrangements and for traffic diversion such as taffic signals during construction at site for day and night, glow lamps, reflective signs, marking flags, caution tape as directed by the engineer-in-charge. The barricading provided shall be retained in psition at site contintously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion . Rate include its maintenance for damages, painting, all incidetanls, labour materials, equipments and works required to execute the job. The barricading shall not be removed without priod approval if engineer-in-charge. (Note One time payment shall be made or prociding barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work.)

920

-

-

... More
Interconnection between existing 1200mm dia psc feeder main and new proposed 200 mm dia pipe line (for sub zone 13 & 21.6A) including dismantling of road, exacavtion, dismantling of psc pipe, supply of machine end, m.s pipe, all weldind material, welding machine, generator, pumpset for dewatering etc all labour, material and t&p required for proper completion of work.

-

-

-

... More
Interconnection between existing 1200mm dia psc feeder main and new proposed 200 mm dia pipe line for 21.6A

1

-

-

... More
Interconnection between existing 600mm dia psc feeder main and new proposed 250 mm dia pipe line for Rajakimandi CWR (SZ 18.1)

1

-

-

... More
Bill II.H-CWR

-

-

-

... More
Design & Supply of all materials, T&P etc required for construction of specified capacty of CWR as per following specifications :-

-

-

-

... More
Capacity -As Specified in Item No 1.1 and 1.2 (rectangular type)

-

-

-

... More
Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion. to inside face of the container,including epoxy paint from inside including refilling and disposing of surplus stuff , all labour and material charges.Cost shall be including giving satisfactory hydraulic test and water tightness test as per IS code.

-

-

-

... More
Soil bearing capacity - Structure shall be design on the basis of maximum bearing capacity of 8 tonne/sqm or minimum as per actual on the basis of test report of soil bearing capacity.

-

-

-

... More
Stair case - 1.0 m wide RCC staircase for enterance inside of CWR.

-

-

-

... More
Ventilator and Water level indicator - RCC ventilator with SS grill (10 sqm at the spacing of 30 mm) with steel mosquito mesh, electronic digital water level indicator with ultrasonic sensor including supply & fixing of solar energy arrangements.

-

-

-

... More
Lightening conductor - A good quality lightening conductor covered with PVC casing.

-

-

-

... More
Inlet/ Outlet pipes and bye pass arrangement with Sluice valve chambers - Supply and fixing of inlet and outlet pipes of CI Pipes with bell mouth and other appurtenant (Sluice valves) works required as per site with sluice valve chamber etc. The velocity in the pipes shall not exceed 1.5 m/s.

-

-

-

... More
Interconnection of existing CWR with newly constructed CWR with Pipe and Isolated (Sluice) valves. The velocity in tha pipe and Isolation Valve shall not exceed 1 m/s.

-

-

-

... More
Construction of CWR with Pump House including meter, Panel Room and Transformer foundation.

-

-

-

... More
Lohamandi Zone

-

-

-

... More
SZ 18.1 (khatipara)

600

-

-

... More
Construction of Scada Control Room as per type design. (10m x 4m x 4 m)

1

-

-

... More
Construction of Chlorinating Room as per type design. (6m x 4m x 4 m)

1

-

-

... More
Construction of Bill collector/ Bill Generator Room

1

-

-

... More
Bodla-III Zone

-

-

-

... More
SZ 21.6A (Paschimpuri)

300

-

-

... More
Construction of Scada Control Room as per type design. (10m x 4m x 4 m)

1

-

-

... More
Construction of Chlorinating Room as per type design. (6m x 4m x 4 m)

1

-

-

... More
Construction of SCADA Control Room as per type design. (30 m x 10 m x 4 m x 2 story)

1

-

-

... More
Construction of Bill collector/ Bill Generator Room

1

-

-

... More
Bodla-I Zone

-

-

-

... More
Construction of Scada Control Room as per type design. (10m x 4m x 4 m)

4

-

-

... More
Construction of Chlorinating Room as per type design. (6m x 4m x 4 m)

4

-

-

... More
Construction of Bill collector/ Bill Generator Room

1

-

-

... More
Rehabilitation of Existing Clear Water Reservoirs

-

-

-

... More
Existing CWR at Sub Zone 19.2 Jaipur House

3800

-

-

... More
Bill II.G-OHT

-

-

-

... More
Design & Supply of all materials, T&P etc required for construction of specified capacity OHT with specified staging as per following requirements:-

-

-

-

... More
Capacity -As Specified against Items with 30m Staging

-

-

-

... More
Grading of OHT - M--35

-

-

-

... More
The food grade epoxy coating of FOSROC / CIEBA GAIKI or reputated brand on the all inside surface area of water container after treatment of water tightness.

-

-

-

... More
Stair case - Seperate two column based RCC staircase and 1 m wide balcony with box type RCC structure at the entrance of the staircase to protect the entry of unwanted persons & locking arrangement with MS door.

-

-

-

... More
Railings - 20 mm dia G.I. Pipe (medium quality steel tubes as per IS 1239) railing consisting of 3 rows of with posts height (50x50x6 mm MS angle) (1.0 m) of same pipe around stair case (both sides), balcony & at the top dome periphery, including epoxy 3mm thick coating above base coat, 65mm dia GI pipe (medium quality steel tubes as per IS 1239) ladder with FRP coating from opening of top dome to inside the tank and top of bottom dome. Supply and fixing of CI man hole cover with locking device at opening on the top dome to go inside the tank.

-

-

-

... More
Ventilator and Water level indicator - RCC ventilator with SS grill (10 sqm at the spacing of 30 mm) with steel mosquito mesh, electronic digital water level indicator with ultrasonic sensor including supply & fixing of solar energy arrangements.

-

-

-

... More
Lightening conductor - A good quality lightening conductor covered with PVC casing

-

-

-

... More
Verticle pipes - Inlet Pipe - 400 mm, outlet pipe - 500 mm, overflow - 400 mm & washout pipe - 100 mm

-

-

-

... More
C.I. D/F pipe as per design criteria upto 1 m beyond the apron, IVC/Kirloskar sluice valve on inlet, out let & at wash out pipe, duck foot bend, puddle collers and bell mouths. 10 mm thick & 150 mm wide S S plate clamp for fixing of verticle pipes with RCC columns (minimum 2 clamps between ends of each pipe). It also includes bye pass arrangement of OHT. The velocity in the pipes shall not exceed 1.5 m/s.

-

-

-

... More
Flooring, Apran & Drain - 100 mm thick PCC of 1:2:4 & 100 mm thick CC of 1:1:2 with 6 mm thick glass strips not more than 1 sqm area upto 2 m from outer edge of the columns of OHT, drain of size 200 mm x 200 mm with 150 mm thick CC of 1:1:2 including necessary sluice valve chambers and pipe line required for proper drainage of rain water from the campus.

-

-

-

... More
Sluice valve chambers - 3 nos. of sluice valve chamber (minimum size 1.5 x 1.5 x 1.5 m or larger size as per requirements of site) of brick work with 200 mm thick RCC slab.

-

-

-

... More
Two coat apex painting over one coat primer of approved colour of asian / berger paints after fixing of RCC surface with grinder, repair of minor holes, unevenness etc. proper completion of work.

-

-

-

... More
Soil bearing capacity - Structure shall be design on the basis of maximum bearing capacity of 8 tonne/sqm or minimum as per actual on the basis of test report of soil bearing capacity.

-

-

-

... More
Lohamandi Zone

-

-

-

... More
SZ 18.1 (Khatipara)

1500

-

-

... More
Bodla-I Zone

-

-

-

... More
SZ 19.2 (Jaipur House)

1500

-

-

... More
Bodla-III Zone

-

-

-

... More
SZ 21.6A (Paschimpuri)

900

-

-

... More
Rising Main

-

-

-

... More
Excavation trenches in all kind of soil with required width of pipes including dewatering if required, shoring, excavation for sockets, and dressing of sides, ramming of bottoms, up to the required depth including removing the excavated soil, and then refilling the soil as required, in layers not exceeding 15 cm in depth including consolidating each deposited layer by ramming, watering etc and disposing of surplus excavated soil as directed, as per Technical Specifications and as per direction of Engineer. The work shall be inclusive of excavation without damaging the underground utilities like electrical and telephone cables, water distribution line, sewer and storm water lines and in case of damages the same shall be replaced with free of cost. The item is also inclusive of reinstatement of damaged sewer /water house service connections during excavation. The drains, public rams and other miscellaneous structures which get damaged while excavating shall be reinstated under this Item. The work is also inclusive of dismantling of Bituminous road,Cement Concrete road, interlocking tiles road sufaces for laying of pipeline and house connection work including sorting out of serviceable material and disposal of unserviceable materials.

-

-

-

... More
0 to 1.5 m depth

4702.75

-

-

... More
Providing and supplying ISI mark DI-k9 S&S pipes (push on joints pressure pipes of D.I of following class and diameters confirming to the I.S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality) including all statutary duties and taxes , Third party inspection charges, including Transit insurance, Railway Freight, Unloading from railway wagon, Loading into Truck, Transportation to departmental store / site of work, unloading, stacking etc. completed as directed by Engineer –in-charge (IS 1536 / 2001 for pipes and IS 158 / 1969 and IS 12820 / 1989 or latest edition / revision with amendments for Rubber Gaskets.

-

-

-

... More
300 mm

700

-

-

... More
350 mm

1500

-

-

... More
400 mm

1400

-

-

... More
Lowering laying and jointing with SBR ruber gaskets D.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment as directed by Engineer in-charge including conveyance of material from stores to site of work, including cost of jointing materials and rubber rings labour, giving hydraulic testing etc. complete. Note : Only SBR Rubber gaskets to be used as per IS-5382 and IS- 12820.

-

-

-

... More
300 mm

700

-

-

... More
350 mm

1500

-

-

... More
400 mm

1400

-

-

... More
Providing,lowering & Laying double flanged Ductile Iron Sluice valves as per specifications including DI tail pieces with EPDM fully covered wedge and epoxy coating internal and external etc complete.

-

-

-

... More
100mm Scour Valve

4

-

-

... More
300 mm

1

-

-

... More
350 mm

1

-

-

... More
400 mm

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing in pipe line Kinetic Double Air Valves as per IS:14845 of following dia including jointing and jointing specials, all material, labour, testing and commissioning as per technical Specifications and as per direction of Engineer-in- charge.

-

-

-

1

-

-

... More
100 mm

4

-

-

... More
Supply and Installation of Full bore Electromagnetic flowmeter including pressure transiducers, RTU , fittings to facilitate the installation with battery power for installation in remote places as specified in the specification of employers requirements.

-

-

-

... More
300 mm

1

-

-

... More
350 mm

1

-

-

... More
400 mm

1

-

-

... More
Providing erecting and commissioning MS dismantling joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia.

-

-

-

... More
100 mm

4

-

-

... More
300 mm

2

-

-

... More
350 mm

2

-

-

... More
400 mm

2

-

-

... More
Re-instatement of following type of road surfaces after laying of pipe line and house connection work including supply of all materials, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement.

-

-

-

... More
Bituminious Road (Sub-Base + Base + BM + PC + Tack coat)

2611.38

-

-

... More
Cement Concrete Road

714.68

-

-

... More
Interlocking Tiles Road

1165.45

-

-

... More
Providing, laying & construction of RCC work of 1:2:4 in thurst block/ casing of pipe line as required during the construction period for laying of pipe lines as directed by Engineer-in-charge including normal form work, compacting, finishing the formed suffaces with CM 1:3 of sufficient minimum thickness to give a smooth and even sugace wherever necessary for proper completion of the work.

7

-

-

... More
Providing and fixing in position steel bar reinforcement required for item no. 12 including cutting bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete (including cost of binding wire and MS Bar)

0.28

-

-

... More
Dismantling of existing Ppipeline of MS/R.C.C/ C.I/P.S.C Pipe excluding the cost of excavation and refilling of trenches and stacking to the place as directed by Engineer in charge with all lead and lifts including the cleaning of surface etc. complete.

-

-

-

... More
100mm to 250 mm diameter

700

-

-

... More
250mm to 500 mm diameter

680

-

-

... More
500mm to 1000 mm diameter

450

-

-

... More
Providing and construction of RCC Chambers for following Feddermain Pipeline Appurtenancess with M-25 Cement Concrete as per Specification and as indicated in the drawing

-

-

-

... More
1. Sluice Valve Chambers

-

-

-

... More
300mm to 550 mm

3

-

-

... More
2. Flowmeter Valve Chambers

-

-

-

... More
300mm to 550 mm

3

-

-

... More
3. Air valve Chambers

-

-

-

1

-

-

... More
100 mm

4

-

-

... More
Scour Valve Chamber with 50m length of laying DN100 DI Pipe

4

-

-

... More
Supply of all material including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, laying and installing MS casing and carrier pipe crossing the National /State Highway and other roads for following sizes with trenchless technology by to correct line and level. The rate to include construction and removal of any jacking platforms, boring and jacking of pipe, removal of excavated material, jointing of casing sections, radiographic testing of joints, internal coating of casing pipe, providing HDPE spacers between the casing and carrier pipes, excavation of jacking and receiving pits, MS shoring/ shuttering, dewatering, 35 cm thick protection brick wall surrounding the pits for protection from entry of waste water of nearby drains, rain water or unwanted material for safety purpose, and backfilling of same to 95% of the standard Proctor density, etc., as indicated in the drawings and specifications.

-

-

-

... More
For 300mm dia of Rising Main/SZ- 18.6 (Ashok Nagar):- Casing Pipe - 500 mm dia MS Pipe (12 mm thick) Carrier Pipe - 300 mm dia MS Pipe (10 mm thick)

110

-

-

... More
For 200mm dia of Rising Main/SZ-18.5 (Gokul Pura):- Casing Pipe - 400 mm dia MS Pipe (10 mm thick) Carrier Pipe - 200 mm dia MS Pipe (8 mm thick)

180

-

-

... More
Disposal of surplus earth /unserviceable material, by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.

369.73

-

-

... More
Providing and erecting 2.0 metre high temporary barricading at site as per drawing direction of Engineer-in-charge which includes writing and painting, arrangements and for traffic diversion such as taffic signals during construction at site for day and night, glow lamps, reflective signs, marking flags, caution tape as directed by the engineer-in-charge. The barricading provided shall be retained in psition at site contintously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion . Rate include its maintenance for damages, painting, all incidetanls, labour materials, equipments and works required to execute the job. The barricading shall not be removed without priod approval if engineer-in-charge. (Note One time payment shall be made or prociding barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work.)

7200

-

-

... More
Distribution Network

-

-

-

... More
Excavation trenches in all kind of soil with required width of pipes including dewatering if required, shoring, excavation for sockets, and dressing of sides, ramming of bottoms, up to the required depth including removing the excavated soil, and then refilling the soil as required, in layers not exceeding 15 cm in depth including consolidating each deposited layer by ramming, watering etc and disposing of surplus excavated soil as directed, as per Technical Specifications and as per direction of Engineer. The work shall be inclusive of excavation without damaging the underground utilities like electrical and telephone cables, water distribution line, sewer and storm water lines and in case of damages the same shall be replaced with free of cost. The item is also inclusive of reinstatement of damaged sewer /water house service connections during excavation. The drains, public rams and other miscellaneous structures which get damaged while excavating shall be reinstated under this Item. The work is also inclusive of dismantling of Bituminous road,Cement Concrete road, interlocking tiles road sufaces for laying of pipeline and house connection work including sorting out of serviceable material and disposal of unserviceable materials.

-

-

-

... More
0 to 1.5 m depth

97266.25

-

-

... More
1.5 to 3 m depth

8

-

-

... More
Supply of High Density Polyethelene Pipes (HDPE (PN-6/PE-100) manufactured from pre compounding resins/polymers material, conforming to IS 4984 / 14151 / 12786 / 13488 in coils/ standard lengths with nesessary jointing material like electro-fusion coupler, flanged joint, including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading & stacking the same in covered shade duly protecting from sunrays & rains, etc. complete as directed by Engineer –in-charge.

-

-

-

... More
110 mm (HDPE (PN-6)/PE-100)

108609

-

-

... More
125 mm (HDPE (PN-6)/PE-100)

1948

-

-

... More
140 mm (HDPE (PN-6)/PE-100)

1207

-

-

... More
160 mm (HDPE (PN-6)/PE-100)

4362

-

-

... More
180 mm (HDPE (PN-6)/PE-100)

321

-

-

... More
Carting, lowering, laying of following dia of HDPE Pipe (PN-6)/PE-100 of following dia and requisite specials to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. Jointing between HDPE pipes and specials shall be done as per the latest IS: 7634 part II. Only Bar coded electro-fusion machine (Automatically Readable) that can read the bar code of the fittings automatically shall be used for jointing of HDPE pipe/fittings.

-

-

-

... More
110 mm (HDPE (PN-6)/PE-100)

108609

-

-

... More
125 mm (HDPE (PN-6)/PE-100)

1948

-

-

... More
140 mm (HDPE (PN-6)/PE-100)

1207

-

-

... More
160 mm (HDPE (PN-6)/PE-100)

4362

-

-

... More
180 mm (HDPE (PN-6)/PE-100)

642

-

-

... More
Providing and supplying ISI mark DI-k7 S&S pipes (push on joints pressure pipes of D.I of following class and diameters confirming to the I.S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality) including all statutary duties and taxes , Third party inspection charges, including Transit insurance, Railway Freight, Unloading from railway wagon, Loading into Truck, Transportation to departmental store / site of work, unloading, stacking etc. completed as directed by Engineer –in-charge (IS 1536 / 2001 for pipes and IS 158 / 1969 and IS 12820 / 1989 or latest edition / revision with amendments for Rubber Gaskets.

-

-

-

... More
200 mm (DI-k7)

2488

-

-

... More
250 mm (DI-k7)

541

-

-

... More
300 mm (DI-k7)

484

-

-

... More
350 mm (DI-k7)

136

-

-

... More
400 mm (DI-k7)

179

-

-

... More
450 mm (DI-k7)

448

-

-

... More
550 mm (DI-k7)

83

-

-

... More
600 mm (DI-k7)

35

-

-

... More
Lowering laying and jointing with SBR ruber gaskets D.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment as directed by Engineer in-charge including conveyance of material from stores to site of work, including cost of jointing materials and rubber rings labour, giving hydraulic testing etc. complete. Note : Only SBR Rubber gaskets to be used as per IS-5382 and IS- 12820.

-

-

-

... More
200 mm (DI-k7)

2488

-

-

... More
250 mm (DI-k7)

541

-

-

... More
300 mm (DI-k7)

484

-

-

... More
350 mm (DI-k7)

136

-

-

... More
400 mm (DI-k7)

179

-

-

... More
450 mm (DI-k7)

448

-

-

... More
550 mm (DI-k7)

83

-

-

... More
600 mm (DI-k7)

35

-

-

... More
Providing,lowering & Laying double flanged Ductile Iron Sluice valves as per specifications including DI tail pieces with EPDM fully covered wedge and epoxy coating internal and external etc complete.

-

-

-

... More
100 mm

62

-

-

... More
150 mm

16

-

-

... More
200 mm

5

-

-

... More
250 mm

5

-

-

... More
350 mm

1

-

-

... More
400 mm

2

-

-

... More
450 mm

2

-

-

... More
600 mm

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing in pipe line Kinetic Double Air Valves as per IS:14845 of following dia including jointing and jointing specials, all material, labour, testing and commissioning as per technical Specifications and as per direction of Engineer-in- charge.

-

-

-

17

-

-

7

-

-

... More
100 mm

7

-

-

... More
Providing erecting and commissioning long collor MS mechanical joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia.

-

-

-

... More
100 mm

92

-

-

... More
150 mm

31

-

-

... More
200 mm

41

-

-

... More
250 mm

25

-

-

... More
300 mm

11

-

-

... More
350 mm

4

-

-

... More
400 mm

8

-

-

... More
450 mm

6

-

-

... More
500 mm

161

-

-

... More
550 mm

31

-

-

... More
600 mm

43

-

-

... More
650 mm

25

-

-

... More
700 mm

11

-

-

... More
750 mm

4

-

-

... More
800 mm

8

-

-

... More
Disinfecting of new water mains by flushing with water containing bleaching powder at 0.5 gms per liter of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the municipal laboratory.

-

-

-

... More
110 mm

101018

-

-

... More
125 mm

1948

-

-

... More
140 mm

1194

-

-

... More
160 mm

4125

-

-

... More
180 mm

321

-

-

... More
200 mm

1581

-

-

... More
250 mm

1480

-

-

... More
300 mm

514

-

-

... More
350 mm

136

-

-

... More
400 mm

125

-

-

... More
450 mm

471

-

-

... More
500 mm

99

-

-

... More
550 mm

66

-

-

... More
600 mm

35

-

-

... More
Providing and constructing R.C.C. chamber with 15 cm thick M - 10 PCC bedding, 15 cm thick bottom slab, walls and precast RCC covers on chamber in RCC M - 20 as per detailed drawing and design including normal dewatering, centering, formwork, bully / steel prop. - UPS, compaction, finishing the formed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface finish with curing including providing and fixing in position steel bar reinforcement of various diameter for RCC slabs, walls etc. including cutting, bending, hooking the bars, binding with wires etc. complete as directed by Engineer - in - charge for following size. The cost shall be inclusive of with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid for the operation sluice valves.

-

-

-

... More
Flow Meter Chamber

-

-

-

... More
100mm to 250 mm

24

-

-

... More
300mm to 550 mm

5

-

-

... More
600mm to 800 mm

1

-

-

... More
Sluice valve Chamber

-

-

-

... More
100mm to 250 mm (Surface Box)

88

-

-

... More
300mm to 550 mm

5

-

-

... More
600mm to 800 mm

1

-

-

... More
Providing and constructing R.C.C. chamber with 15 cm thick M - 10 PCC bedding, 15 cm thick bottom slab, walls and precast RCC covers on chamber in RCC M - 20 as per detailed drawing and design including normal dewatering, centering, formwork, bully / steel prop. - UPS, compaction, finishing the formed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface finish with curing including providing and fixing in position steel bar reinforcement of various diameter for RCC slabs, walls etc. including cutting, bending, hooking the bars, binding with wires etc. complete as directed by Engineer - in - charge for following size.The cost shall be inclusive of with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid for the operation sluice valves.

-

-

-

... More
Air Valve Chamber

-

-

-

... More
50 mm dia VC

17

-

-

... More
80mm dia and above

14

-

-

... More
Scour Valve Chamber

22

-

-

... More
Providing new water supply house connection to the consumers from new distribution pipe line of following diameters including making ferrule connection, cost of ferrule, 15 mm dia HDPE and GI pipe, saddle piece, ball valve, specials, excavation, refilling of pit etc. complete. It also includes supply of all materials, labour, T&P etc. required for proper completion of the work. As per attached drawing.

-

-

-

... More
15 mm dia

10307

-

-

... More
Disconnection/Reconnection of old connections, inlcuding necessary excavation, cutting of pipe, dismantling pipe, plugging of pipeline & refilling etc. complete (including specials ) in all sizes of coonetion

-

-

-

... More
Disconnection/Reconnection of 15mm Diameter HSC

6044

-

-

... More
Supply, delivery, installation and testing of Smart AMR Electromagnetic R500 water meters MID approved, with no measurement of Air, along with manufacturing Calibration certificate, with in built RF Technology for communication, General Specifications :- 1)Meter should be battery operated with no moving parts, low pressure loss as per ISO 4064 / OIML R49 /MID Certified. 2) Display: =8 digit LCD, 3) Protection class IP 68. 4) Temperature: Ambient 50 deg. C. 5) Pressure: PN - 16, 6) Power Supply: lithium battery with minimum life of 10 years. 7) End Connection : Screwed 8) Installation : Should be able to install in any orientation (For detail specification, refer to Technical Specification)

-

-

-

... More
15 mm dia

16351

-

-

... More
Provideing and suppling meter reading device (Android OS)

6

-

-

... More
Provideing and suppling meter reading software for meter reding device (Android OS) base one time

1

-

-

... More
Annual Mainteinance /Software upgradation for Meter Reding Device (Android OS Based) one time

1

-

-

... More
Providing and supplying billing software for water meter redings

1

-

-

... More
Providing and fixing water meter box of HDPE/GRP material , including necessary excavation, cost of locking arrangement etc complete of suitable size for 15 to 100 mm dia.

-

-

-

... More
15 mm dia

16351

-

-

... More
Supply and Installation of Full bore Electromagnetic flowmeter including pressure transiducers, RTU , fittings to facilitate the installation with battery power for installation in remote places as specified in the specification of employers requirements.

-

-

-

... More
100 mm

8

-

-

... More
150 mm

6

-

-

... More
200 mm

5

-

-

... More
250 mm

5

-

-

... More
350 mm

1

-

-

... More
400 mm

2

-

-

... More
450 mm

2

-

-

... More
600 mm

1

-

-

... More
GSM base Software suitable for bulk flowmeters i.e. insertion type ultrasonic flow meter and full bore electromagnetic flow meter to transmit real time data in the remote PC / Server

1

-

-

... More
Repair / Dismantling of old leaking CI pipe with new pipe and joints of same diameter DI Class K7 Pressure Pipes (S&S) conforming to IS 8329 with including cost of cutting and removing old pipes and specials, cutting of pipe piece for required length, lead joint / cement joint / tyton joint preparation.

-

-

-

... More
Supply and Installation of consumer water meter test bench capable of testing water meters of sizes (15 and 100mm ) size

4

-

-

... More
Re-instatement of following type of road surfaces after laying of pipe line and house connection work including supply of all materials, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement.

-

-

-

... More
Bituminious Road (Sub-Base + Base + BM + PC + Tack coat)

43357.18

-

-

... More
Cement Concrete Road

11959.89

-

-

... More
Interlocking Tiles Road

16716.52

-

-

... More
Providing supplying, fixing and commissioning GPRS enabled Data logger with internal battery having (3 years battery life) additional battery packs to ensure data ransmission frequency of every 30 mins , pressure loggingdual channel for flow and pressure logging with internal pressure transducer, one PDA for local download , PC software, PC connection cable, Infra-red reading head, pressure hose, instruction manual etc. complete as directed by the Engineer-in-charge.The rate is inclusive of all taxes installation , integration, testing etc. complete. or as directed by Engineer-in-charge. rate inclusive of Supply and installation of FRP cabinet below ground for dataloggers as per specifications.

44

-

-

... More
Providing, laying & construction of RCC work of 1:2:4 in thurst block/ casing of pipe line as required during the construction period for laying of pipe lines as directed by Engineer-in-charge including normal form work, compacting, finishing the formed suffaces with CM 1:3 of sufficient minimum thickness to give a smooth and even sugace wherever necessary for proper completion of the work.

30

-

-

... More
Providing and fixing in position steel bar reinforcement required for item no. 31 including cutting bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete (including cost of binding wire and MS Bar)

3

-

-

... More
Construction of single tap RCC pillar type stand post as per type design.

34

-

-

... More
Repairing of sewer house connection which is coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work.

526

-

-

... More
Repairing of sewer man hole/ house connecting chamber which is coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work.

190

-

-

... More
Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work.

-

-

-

... More
Brick masonry in cement mortar 1:4

140

-

-

... More
12mm thick plaster in cement mortar 1:4

564

-

-

... More
RCC M-20 (including MS work)

36

-

-

... More
Provision for crossing of Nalas (0.5m to 2.0 m width) for laying of pipe line including necessary specials, T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain.

-

-

-

... More
0.5 - 1.0 m

4

-

-

... More
1.0 - 1.5 m

11

-

-

... More
1.5 - 2.0 m

4

-

-

... More
Misc-(With Rate)

-

-

-

... More
Construction of Boundry wall around campus as per unit estimate with RCC Columns @ 3.0m c/c distance with plinth beam and brick work in 1:4 including supply bof all materials T& P etc complete

-

-

-

... More
OHT campus

-

-

-

... More
CWR campus (Water sub merged location)

-

-

-

525

-

-

... More
Supply and fixing M S iron gate 4.5M wide with a wicket gate including primer and painting etc all complete

3

-

-

... More
Construction of PCC drain 250 x 250 mm & PCC 1:2:4 over PCC 1:4:8 foundation including supply of all material, labour, T&P etc. required for proper completion of the work.

580

-

-

... More
Earth filling

-

-

-

... More
CWR Campus

300

-

-

... More
OHT Campus

410

-

-

... More
Horticulture and other development works

-

-

-

... More
OHT Campus

2

-

-

... More
Construction of following types of Road/ flooring for development of CWR / OHT campus required as per site condition

-

-

-

... More
C.C. Road

390

-

-

... More
Construction of Pump oprater room set

2

-

-

... More
E/M Works

-

-

-

... More
Bill II-F Pumping Station (Bodla-III)

-

-

-

... More
Providing, erecting, commissioning and giving test and trial of VT pumps including motors, water lubricated type and having following duty point,operating speed including providing and fixing ISMB grating etc, as per detailed specifications.

-

-

-

... More
SZ 21.6A: Discharge 43.6 LPS, head 36m, speed 1480 rpm with suitable KW rating of motor

2

-

-

... More
Supply of double flanged short body pattern butterfly valve and related hardware, including chair support, etc., conforming to IS 13095/BS EN 593, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of valve assembly measured separately).

-

-

-

... More
SZ 21.6A: 200 mm diameter

2

-

-

... More
Supply of double flanged, short body sluice valves and related hardware conforming to IS 14846, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of valve assembly measured separately).

-

-

-

... More
SZ 21.6A: 200 mm diameter

2

-

-

... More
Supply of flanged Kinetic air valve including isplated sluice valve and related hardware conforming to IS 14845 / C512, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of valve assembly measured separately).

-

-

-

... More
80 mm dia

1

-

-

... More
Supply of dismantling joints and related hardware, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of dismantling joint measured separately).

-

-

-

... More
SZ 21.6A: 200 mm diameter

2

-

-

... More
Providing and supplying ISI markCI D/F reflux valves (non-returnvalves ) of following dia includingall taxes (Central and Local),railway freight, inspection chargesunloding from railway wagon,loading into truck, transportation upto departmental stroes/ site,unloading, stacking etc. complete. Reflux valves as per I.S.5312 Part I(1984) ( installation of valve assembly measured separately).

-

-

-

... More
SZ 21.6A: 200 mm diameter

2

-

-

... More
Providing, errecting, commissioning and testing of non clog sump pump sets having pump discharge capacity of 30 LPS raw water with silt and mid at a total head of 30m with piping and other necessary arrangements.

-

-

-

... More
Q=30LPS, H=30m with suitable KW rating of motor

1

-

-

... More
Providing, fabricating, testing, transporting, and handling mild steel pipes and bends as per IS 5504, IS 3589 and the specifications and drawings. The rate to include transportation of pipes to site, loading, unloading, storage, guarding, and issuance to works as per specifications. The rates shall be inclusive of Collecting materials from storage, loading, transporting, unloading, laying and jointing/ welding pipe connections to correct line and level as per the specifications and drawings. The rate to include hoisting, lowering, marginal cutting wherever necessary, assembling, providing supports, thrust blocks, anchor blocks etc., as per specifications and drawings. The rate also includes testing of field joints . The rate shall also inclusive of internal and external epoxy coating and lining for corrosion protections as specified in the Specifications.

-

-

-

... More
Individual header

-

-

-

... More
SZ 21.6A: 200 mm diameter

6

-

-

... More
Common Header

-

-

-

... More
SZ 21.6A: 250 mm diameter

4

-

-

... More
Supply and errection of new Electrical Operated Crane (EOT)

-

-

-

... More
5 Tonne Capacity and 6 to 10m length

1

-

-

... More
Designing, manufacturing, providing, erecting and fixing altitude control valve for maintaining water level in the service reservoir and reducing NRW on account of overflowing. (Singer/Equivalent makes 106-A-Type 4- One-Way flow with adjustable differential, altitude control valve fully mechanically operated). including 2 isolation DI Valve on upstream & downstream of Altitude Valve

-

-

-

... More
SZ 21.6A: 250 mm diameter

1

-

-

... More
Providing, erecting electric Valve actuators totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous localmechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volts +/- 10%, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be atleast 1.5 times max. torque required for opening and closing of valve with integral starter for ON & OFF operation

-

-

-

... More
Modulating Type for Butterfly Valve

-

-

-

... More
SZ 21.6A : 200 mm diameter

2

-

-

... More
Bill II-F Pumping Station (Bodla-I)

-

-

-

... More
Providing, erecting, commissioning and giving test and trial of VT pumps including motors, water lubricated type and having following duty point,operating speed including providing and fixing ISMB grating etc, as per detailed specifications.

-

-

-

... More
SZ 19.2: Discharge 79.2 LPS, head 34m, speed 1480 rpm (1D+1S), with suitable KW rating of motor

2

-

-

... More
Supply of double flanged short body pattern butterfly valve and related hardware, including chair support, etc., conforming to IS 13095/BS EN 593, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of valve assembly measured separately).

-

-

-

... More
SZ 19.2: 250 mm diameter

2

-

-

... More
Supply of double flanged, short body sluice valves and related hardware conforming to IS 14846, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of valve assembly measured separately).

-

-

-

... More
SZ 19.2: 250 mm diameter

2

-

-

... More
Supply of flanged Kinetic air valve including isplated sluice valve and related hardware conforming to IS 14845 / C512, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of valve assembly measured separately).

-

-

-

... More
100 mm dia

1

-

-

... More
Supply of dismantling joints and related hardware, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of dismantling joint measured separately).

-

-

-

... More
SZ 19.2: 250 mm diameter

2

-

-

... More
Providing and supplying ISI markCI D/F reflux valves (non-returnvalves ) of following dia includingall taxes (Central and Local),railway freight, inspection chargesunloding from railway wagon,loading into truck, transportation upto departmental stroes/ site,unloading, stacking etc. complete. Reflux valves as per I.S.5312 Part I(1984) ( installation of valve assembly measured separately).

-

-

-

... More
SZ 19.2: 250 mm diameter

2

-

-

... More
Providing, errecting, commissioning and testing of non clog sump pump sets having pump discharge capacity of 30 LPS raw water with silt and mid at a total head of 30m with piping and other necessary arrangements.

-

-

-

... More
Q=30LPS, H=30m with suitable KW rating of motor

1

-

-

... More
Providing, fabricating, testing, transporting, and handling mild steel pipes and bends as per IS 5504, IS 3589 and the specifications and drawings. The rate to include transportation of pipes to site, loading, unloading, storage, guarding, and issuance to works as per specifications. The rates shall be inclusive of Collecting materials from storage, loading, transporting, unloading, laying and jointing/ welding pipe connections to correct line and level as per the specifications and drawings. The rate to include hoisting, lowering, marginal cutting wherever necessary, assembling, providing supports, thrust blocks, anchor blocks etc., as per specifications and drawings. The rate also includes testing of field joints . The rate shall also inclusive of internal and external epoxy coating and lining for corrosion protections as specified in the Specifications.

-

-

-

... More
Individual header

-

-

-

... More
SZ 19.2: 250 mm diameter

6

-

-

... More
Common Header

-

-

-

... More
SZ 19.2: 300 mm diameter

4

-

-

... More
Supply and errection of new Electrical Operated Crane (EOT)

-

-

-

... More
10 Tonne Capacity and 10m length

1

-

-

... More
Dismantling of Existing pumps, pipes, valves and other appurtenances, fittings and accessories in the puming station to install the new pumps, pipes and pipe appurtenances.

-

-

-

... More
Existing Pumping Station

1

-

-

... More
Designing, manufacturing, providing, erecting and fixing altitude control valve for maintaining water level in the service reservoir and reducing NRW on account of overflowing. (Singer/Equivalent makes 106-A-Type 4- One-Way flow with adjustable differential, altitude control valve fully mechanically operated). including 2 isolation DI Valve on upstream & downstream of Altitude Valve

-

-

-

... More
SZ 19.2: 300 mm diameter

1

-

-

... More
Providing, erecting electric Valve actuators totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous localmechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volts +/- 10%, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be atleast 1.5 times max. torque required for opening and closing of valve with integral starter for ON & OFF operation

-

-

-

... More
Modulating Type for Butterfly Valve

-

-

-

... More
SZ 19.2: 250 mm diameter

2

-

-

... More
Bill II-F Pumping Station (Lohamandi)

-

-

-

... More
Providing, erecting, commissioning and giving test and trial of VT pumps including motors, water lubricated type and having following duty point,operating speed including providing and fixing ISMB grating etc, as per detailed specifications.

-

-

-

... More
SZ 18.1: Discharge 86.9 LPS, head 41m, speed 1480 rpm with suitable KW rating of motor

2

-

-

... More
Supply of double flanged short body pattern butterfly valve and related hardware, including chair support, etc., conforming to IS 13095/BS EN 593, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of valve assembly measured separately).

-

-

-

... More
SZ 18.1: 300 mm diameter

2

-

-

... More
Supply of double flanged, short body sluice valves and related hardware conforming to IS 14846, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of valve assembly measured separately).

-

-

-

... More
SZ 18.1: 300 mm diameter

2

-

-

... More
Supply of flanged Kinetic air valve including isplated sluice valve and related hardware conforming to IS 14845 / C512, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of valve assembly measured separately).

-

-

-

... More
100 mm dia

1

-

-

... More
Supply of dismantling joints and related hardware, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications ( installation of dismantling joint measured separately).

-

-

-

... More
SZ 18.1: 300 mm diameter

2

-

-

... More
Providing and supplying ISI markCI D/F reflux valves (non-returnvalves ) of following dia includingall taxes (Central and Local),railway freight, inspection chargesunloding from railway wagon,loading into truck, transportation upto departmental stroes/ site,unloading, stacking etc. complete. Reflux valves as per I.S.5312 Part I(1984) ( installation of valve assembly measured separately).

-

-

-

... More
SZ 18.1: 300 mm diameter

2

-

-

... More
Providing, errecting, commissioning and testing of non clog sump pump sets having pump discharge capacity of 30 LPS raw water with silt and mid at a total head of 30m with piping and other necessary arrangements.

-

-

-

... More
Q=30LPS, H=30m with suitable KW rating of motor

1

-

-

... More
Providing, fabricating, testing, transporting, and handling mild steel pipes and bends as per IS 5504, IS 3589 and the specifications and drawings. The rate to include transportation of pipes to site, loading, unloading, storage, guarding, and issuance to works as per specifications. The rates shall be inclusive of Collecting materials from storage, loading, transporting, unloading, laying and jointing/ welding pipe connections to correct line and level as per the specifications and drawings. The rate to include hoisting, lowering, marginal cutting wherever necessary, assembling, providing supports, thrust blocks, anchor blocks etc., as per specifications and drawings. The rate also includes testing of field joints . The rate shall also inclusive of internal and external epoxy coating and lining for corrosion protections as specified in the Specifications.

-

-

-

... More
Individual header

-

-

-

... More
SZ 18.1: 300 mm diameter

6

-

-

... More
Common Header

-

-

-

... More
SZ 18.1: 350 mm diameter

4

-

-

... More
Supply and errection of new Electrical Operated Crane (EOT)

-

-

-

... More
5 Tonne Capacity and 10m length

1

-

-

... More
Designing, manufacturing, providing, erecting and fixing altitude control valve for maintaining water level in the service reservoir and reducing NRW on account of overflowing. (Singer/Equivalent makes 106-A-Type 4- One-Way flow with adjustable differential, altitude control valve fully mechanically operated). including 2 isolation DI Valve on upstream & downstream of Altitude Valve

-

-

-

... More
SZ 18.1: 350 mm diameter

1

-

-

... More
Providing, erecting electric Valve actuators totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous localmechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volts +/- 10%, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be atleast 1.5 times max. torque required for opening and closing of valve with integral starter for ON & OFF operation

-

-

-

... More
Modulating Type for Butterfly Valve

-

-

-

... More
SZ 18.1: 300 mm diameter

2

-

-

... More
Torrent Power/UPPCL cable/pole/transformer shifting proposal

-

-

-

... More
supply of all materials, labour, T&P etc. required for shifting of following utilities/obstructions which are coming in alignment pipe line

-

-

-

... More
33 KV UG Cable (630/3C) / (400/3C) Shifting (20 m Span)

15

-

-

... More
33 KV UG Cable (630/3C) / (400/3C) Joints

30

-

-

... More
33 KV Single Pole Shifting

45

-

-

... More
33 KV Double Pole Shifting

15

-

-

... More
11 KV UG Cable (240/3C) Shifting (20 m Span)

75

-

-

... More
11 KV UG Cable (70/3C) Shifting (20 m Span)

45

-

-

... More
11 KV UG Cable (240/3C) Joints

30

-

-

... More
11 KV UG Cable (400/3C) Joints

30

-

-

... More
11 KV Single Pole Shifting

30

-

-

... More
11 KV Single Doubl Pole Structure Shifting

15

-

-

... More
Pole Mounted Distribution Transformer

15

-

-

... More
Plinth Mounted Distribution Transformer

15

-

-

... More
Ring Main Unit Shifting

15

-

-

... More
LT UG Span Shifting (Incl. MSP)

375

-

-

... More
LT Individual MSP Shifting

210

-

-

... More
LT OH Span Shifting (Incl. Pole)

180

-

-

... More
LT Individual Pole Shifting

165

-

-

... More
Electrical and Instrumentation Works for Bodla-I Pilot Zone

-

-

-

... More
Electrical System

-

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 11kV indoor switchboard as per approved single line diagram at Jaipur House pumping Station

1

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 110V Ni-Cd battery, battery charger & DC distribution board and accessories

1

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 11/.433 kV, 160 kVA , ONAN, transformer with OCTC (±10%, taps at 1.25%) at B-1, Jaipur House pumping Station

2

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, Indoor Switch board PMCC panel (including 3 soft starters, Lighting and Power arrangements) at Jaipur House pumping Station

1

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, APFC panel at Jaipur House pumping Station

1

-

-

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - external lighting at pumping Stations

1

-

-

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, utility sockets (3ph and 1ph.) and necessary accessories - internal lighting at pumping Stations

1

-

-

... More
Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories at pumping Station

1

-

-

... More
Complete cabling system with HV Power cables, cable trays, route marker, steel structure for cable trench, pipes and accessories at pumping Station

1

-

-

... More
Complete cabling system with LV power and control cables, cable trays, route marker, steel structure for cable trench, pipes and accessories at pumping Station

1

-

-

... More
Start stop Push Button Stations at pumping Station

2

-

-

... More
Any other item ( transformer fencing, Panel and metering Room etc) & accessories not specified above but required to complete the Electrical work.

1

-

-

... More
Instrumentation System: Installation of Instrumentation and Control Equipment including, but not limited to, safe storage, protection, civil works, erection, installation, testing and commissioning required to complete the Works in all respects for the following equipment:

-

-

-

... More
Instrument control panel comprising Digital Panel meters,PLC, HMI, push button stations, alarm anunciator, selector switches, etc. with data transmission provisions

1

-

-

... More
Ultrasonic type level measurement system

1

-

-

... More
Float type level switch

1

-

-

... More
Pressure measurement system PIT for pumping main.

1

-

-

... More
Pressure gauges on discharge of pumps.

2

-

-

... More
Residual Chlorine Measurement system

1

-

-

... More
Pressure switches

2

-

-

... More
Instrumentation & control cables alongwith cable glands and lugs, cable trays / conduits and all the installattion hardware

1

-

-

... More
Complete instrumentation earthing system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories

1

-

-

... More
3 phase, 415 V UPS System with all accessaries for SCADA System

1

-

-

... More
Electrical and instrumentation cable trays, fasteners, cable route marker, cable termination and any other item & accessories required to complete the work.

1

-

-

... More
Electrical & Instrumentation Works for the Bodla-III Pilot Zone

-

-

-

... More
Electrical System

-

-

-

... More
Arrangement of 11 kV power suppy at Pumping Stations including 11kV outdoor substation, pole structure, metering room, LA, CT, PT, disconnector, fuse, ACSR conductor, pin & disc insulators, clamp & connectors with metering unit including steel structure as applicable as per approved single line diagram at Paschim Puri A&B

1

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 11kV indoor switchboard as per approved single line diagram at pumping Station

1

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 11/.433 kV, 160 kVA, ONAN, transformer with OCTC (±10%, taps at 1.25%) at paschim puri-A pumping Station

2

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, Indoor Switch board PMCC panel at (including 3 soft starters, Lighting and Power arrangements) at paschim puri-A pumping Station

1

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, APFC panel at paschim puri- A pumping Station

1

-

-

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - external lighting at pumping Station

1

-

-

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, utility sockets (3ph and 1ph.) and necessary accessories - internal lighting at pumping Station

1

-

-

... More
Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories at pumping Station

1

-

-

... More
Complete cabling system with HV Power cables, cable trays, route marker, steel structure for cable trench, pipes and accessories at pumping Station

1

-

-

... More
Complete cabling system with LV power and control cables, cable trays, route marker, steel structure for cable trench, pipes and accessories at pumping Station

1

-

-

... More
Start stop Push Button Stations at pumping Station

2

-

-

... More
Any other item ( Transformer fencing, Panel and metering Room etc) & accessories not specified above but required to complete the Electrical work.

1

-

-

... More
Instrumentation System: Installation of Instrumentation and Control Equipment including, but not limited to, safe storage, protection, civil works, erection, installation, testing and commissioning required to complete the Works in all respects for the following equipment:

-

-

-

... More
Instrument control panel comprising Digital Panel meters,PLC, HMI, push button stations, alarm anunciator, selector switches, etc. with data transmission provisions

1

-

-

... More
Ultrasonic type level measurement system

1

-

-

... More
Float type level switch

1

-

-

... More
Pressure measurement system PIT for pumping main.

1

-

-

... More
Pressure gauges on discharge of pumps.

2

-

-

... More
Residual Chlorine Measurement system

1

-

-

... More
Pressure switches

2

-

-

... More
Instrumentation & control cables alongwith cable glands and lugs, cable trays / conduits and all the installattion hardware

1

-

-

... More
Complete instrumentation earthing system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories

1

-

-

... More
3 phase, 415 V UPS System with all accessaries for SCADA System

1

-

-

... More
Electrical and instrumentation cable trays, fasteners, cable route marker, cable termination and any other item & accessories required to complete the work.

1

-

-

... More
Electrical & Instrumentation Works for the Loha Mandi Pilot Zone

-

-

-

... More
Electrical System

-

-

-

... More
Arrangement of 11 kV power suppy at Pumping Stations including 11kV outdoor substation, pole structure, metering room, LA, CT, PT, disconnector, fuse, ACSR conductor, pin & disc insulators, clamp & connectors with metering unit including steel structure as applicable as per approved single line diagram

1

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 11kV indoor switchboard as per approved single line diagram at pumping Station

1

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 11/.433 kV, 250 kVA , ONAN, transformer with OCTC (±10%, taps at 1.25%) at Khatipada Pumping Station

2

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, Indoor Switch board PMCC panel (including 3 soft starters, Lighting and Power arrangements) at Khatipada Pumping Station

1

-

-

... More
Design, Supply, Installation, Testing and Commissioning of 415 V, APFC panel at Khatipada Pumping Station

1

-

-

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - external lighting at pumping Station

1

-

-

... More
Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, utility sockets (3ph and 1ph.) and necessary accessories - internal lighting at pumping Station

1

-

-

... More
Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories at pumping Station

1

-

-

... More
Complete cabling system with HV Power cables, cable trays, route marker, steel structure for cable trench, pipes and accessories at pumping Station

1

-

-

... More
Complete cabling system with LV power and control cables, cable trays, route marker, steel structure for cable trench, pipes and accessories at pumping Station

1

-

-

... More
Start stop Push Button Stations at pumping Station

2

-

-

... More
Any other item ( Transformer fencing, Panel and metering Room etc) & accessories not specified above but required to complete the Electrical work.

1

-

-

... More
Instrumentation System: Installation of Instrumentation and Control Equipment including, but not limited to, safe storage, protection, civil works, erection, installation, testing and commissioning required to complete the Works in all respects for the following equipment:

-

-

-

... More
Instrument control panel comprising Digital Panel meters, PLC HMI, push button stations, alarm anunciator, selector switches, etc. with data transmission provisions

1

-

-

... More
Ultrasonic type level measurement system

1

-

-

... More
Float type level switch

1

-

-

... More
Pressure measurement system PIT for pumping main.

1

-

-

... More
Pressure gauges on discharge of pumps.

2

-

-

... More
Residual Chlorine Measurement system

1

-

-

... More
Pressure switches

1

-

-

... More
Instrumentation & control cables alongwith cable glands and lugs, cable trays / conduits and all the installattion hardware

1

-

-

... More
Complete instrumentation earthing system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories

1

-

-

... More
3 phase, 415 V UPS System with all accessaries for SCADA System

1

-

-

... More
Electrical and instrumentation cable trays, fasteners, cable route marker, cable termination and any other item & accessories required to complete the work.

1

-

-

... More
O & M Works for (PCM)-Bill-III Operation and Maintenance of three Pilot Zones works. Refer the Technical Specification Section for a more details Description.

-

-

-

... More
Year-1

12

-

-

... More
Year-2

12

-

-

... More
Year-3

12

-

-

... More
Year-4

12

-

-

... More
Year-5

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.