UP Jal Nigam Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

UP Jal Nigam - UPJN Tender

Works
Civil And Construction
Solid Waste Management
Drainage Work
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date1 Apr 2025
Closing Soon7 May 2025
Tender Amount₹ 16,88,76,692 
Notes
Download

Costs

Summary

Interception And Diversion (i And D) And Stp For Existing Drain In Sherkot Town Npp Distt Bijnor

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(a) 0.00 to 1.50 m

16390.66

252

4132085.39

... More
(b) 01.50 to 03.00 m

14113.43

317

4482989.91

... More
(c) 03.00 to 04.50 m

11750.41

399

4690998.68

... More
(d) 04.50 to 06.00 m

3832.58

466

1788780.06

... More
Provide and fix close timbering in trenches for the depth as specified below G.L. consisting of 40 mm thick approved country wood plank for polling board 125 x 75 mm eucalyptus-Safeda-Sal Wood wallers and 100 mm dia ballies for shuttering at 1.5 m C/C including all labour etc , complete

-

-

-

... More
(a) 1.50 to 3 m

5364.75

514

2758876.34

... More
(b) 03.00 to 06.00 m

5943.28

668

3975222.26

... More
Same as item No. 3 but for open timbering (No timbering for the depth 1.5m)

-

-

-

... More
(a) 1.5 to 03.00 m

609.62

292

178088.29

... More
Supply of following sizes of RCC spigotted and socketed non pressure pipes( Dia. In mm ) with structural strength as per IS 458 : 2003 and its latest amendment(s). NP3

-

-

-

... More
200 mm dia

398

371

147980.38

... More
250 mm dia

441

439

193819.5

... More
300 mm dia

213

618

131674.47

... More
350 mm dia

1005

1086

1091992.8

... More
400 mm dia

849

1207

1025159.01

... More
450 mm dia

485

1332

646471.05

... More
500 mm dia

275

1738

477988.5

... More
600 mm dia

649

2046

1328360.22

... More
700 mm dia

481

2462

1184611.61

... More
900 mm dia

1634

4007

6548777.88

... More
Carting following sizes of R.C.C. Hume pipe NP3 Class Socket / spigot rubber ring jointing and specials from store to the work lowering and laying the same in to the trenches upto depth as specified below G.L. true to alignment 200 mm dia pipe

-

-

-

... More
00.00 - 0 1.50 m

14

608

8517.88

... More
01.50 - 0 3.00 m

384

647

248705.28

... More
250 mm dia pipe

-

-

-

... More
00.00 - 0 1.50 m

62

699

43356.6

... More
01.50 - 0 3.00 m

136

744

101239.76

... More
03.00 - 04.50 m

79

790

62454.24

... More
04.50 - 06.00 m

164

844

138483.24

... More
300 mm dia pipe

-

-

-

... More
03.00 - 04.50 m

213

876

186671.07

... More
350 mm dia pipe

-

-

-

... More
00.00 - 0 1.50 m

55

849

46706

... More
01.50 - 0 3.00 m

61

903

55142.17

... More
03.00 - 04.50 m

252

960

241925.04

... More
04.50 - 06.00 m

637

1025

653186.17

... More
400 mm dia pipe

-

-

-

... More
00.00 - 0 1.50 m

9

928

8356.32

... More
01.50 - 0 3.00 m

144

988

142323.84

... More
03.00 - 04.50 m

516

1049

541614.24

... More
04.50 - 06.00 m

180

1121

201805.2

... More
450 mm dia pipe

-

-

-

... More
01.50 - 0 3.00 m

282

1223

345094.68

... More
03.00 - 04.50 m

203

1299

263820.83

... More
500 mm dia pipe

-

-

-

... More
01.50 - 0 3.00 m

18

1327

23902.74

... More
03.00 - 04.50 m

257

1410

362436.82

... More
600 mm dia pipe

-

-

-

... More
01.50 - 0 3.00 m

486

1458

708665.76

... More
04.50 - 06.00 m

163

1654

269608.52

... More
700 mm dia pipe

-

-

-

... More
03.00 - 04.50 m

106

1822

193221.04

... More
04.50 - 06.00 m

375

1946

730121.25

... More
900 mm dia pipe

-

-

-

... More
00.00 -0 1.50 m

13

2186

28420.47

... More
03.00 - 04.50 m

286

2471

706843.28

... More
04.50 - 06.00 m

1335

2639

3524159.7

... More
Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work.

-

-

-

... More
(a) 00.00 to 01.50 m

7.65

6473

49503.72

... More
(b) 01.50 to 03.00 m

102.91

6531

672151.52

... More
(c) 03.00 to 04.50 m

368.48

6609

2435332.22

... More
(d) 04.50 to 06.00 m

934.24

6706

6265228.32

... More
Filling granular material (well graded crushed rock or gravel maximum size 20mm) into the trenches for class B bedding (granular bedding) including watering compaction, labour T&P etc. for completion of work. (As per statement)

-

-

-

... More
(a) 00.00 to 01.50 m

5.46

122

667.21

... More
(b) 01.50 to 03.00 m

118.61

125

14929.44

... More
Supply (excluding cartage) of granular material (well graded crushed rock or gravel of maximum size 20mm) for class B bedding (granular bedding)

124.07

2140

265587.96

... More
Construction of circular type brick masonry HD (HD25) manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:4 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete with including Plastic Encapsulated M.S. foot Rest staggered at 0.375 mtr interval, including excavation, reinforcement

-

-

-

... More
900mm internal dia., 1.65m deep

9

15785

142066.53

... More
1200mm internal dia., 3.30m deep

60

38787

2327220

... More
1500mm internal dia., 4.95m deep

118

105846

12489942.46

... More
Extra for every additional depth of 1 m or part there of in following size of circular manholes.

-

-

-

... More
900mm internal dia., 1.65m deep

1.26

6331

-7978.19

... More
1200mm internal dia., 3.30m deep

22.08

9542

-210690.23

... More
1500mm internal dia., 4.95m deep

138.24

23236

-3212263.53

... More
Dismantling/Cutting of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer-incharge.

-

-

-

... More
Bituminous road

824.48

172

142189.82

... More
Concrete road

256.06

172

44275.77

... More
Interlocking tile road

9478.01

134

1277920.09

... More
B.O.E road

1188.05

90

107078.95

... More
Reinstatement of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materialsas per direction of Engineer-incharge.

-

-

-

... More
Bituminous road

824.48

1441

1188883.67

... More
Concrete road

256.06

1099

281645.7

... More
Interlocking tile road

9478.01

591

5608517.64

... More
B.O.E road

1188.05

271

322068.48

... More
Tack & SDBC Coat on existing BT Road (remaining area after reinstatement)

2663.02

270

720986.04

... More
Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating

-

-

-

... More
900 mm dia pipe,10mm Pipe Wall Thickness

50

20980

1049019.5

... More
Installation of product pipe by HDD method including preparing and setting up the plants and equipement, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per IndSTT:101:2018: Code of prectice of HDD Technique Suiting Indian Conditions and as per direction of Engineer-incharge.

-

-

-

... More
900 mm dia pipe

50

15154

757705.5

... More
Permission charges payable to the NHAI to taking permission for laying the pipe

1

767090

767090.9

... More
Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying.

3215

82

264176.55

... More
Disposal of Surplus Earth as per direction of Engineer-incharge.

8353

185

1553240.35

... More
Construction of Boundary Wall 2.0 m ht. above plinth level and 0.23 m width with RCC Column @3m c/c with plinth beam and foundation avg. 1.2m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site

300

6797

2039130

... More
MS gate (3.6m wide with 1.5m wicket gate with 0.35 x 0.35m RCC pillers)

1

48550

48550.7

... More
Proposal for Supply of 1500 Ltr Capacity Sewer Suction Machine mounted on TATA 407 Gold/2900 WB Truck Chassis.

1

1167000

1167000

... More
Interception and diversion (I&D) Structure works

-

-

-

... More
I&D Structure with 1 no. S.S. gate across the Drain and 1 no. S.S. gate at the diversion pipe inlet)

6

464009

2784056.34

... More
STP ( 6 MLD ) And Co Treat ment Plant ( 16 KLD ) Design, Supply of all Materials, Erection, Testing,Commissioning and 3 month trial run Of Electrical, Mechanical & Instrumentation Equipments at STP (6 MLD ) with all required electrical & mechanical works, PLC/SCADA work, electrification & street lighting work and Online Continuous Effluent Monitoring System (OCEMS) etc. all complete as per tender document for STP.The effluent quality for agricultural uses ( PH-6.5 TO 8.3,SS-30 mg/l, Oil & Greases -10mg/l, BOD- 10mg/l,COD-30 mg/l,Residual Chlorine-nil, TKN-10mg/l, Nitrate-10mg/l, FC-230MPN/100ml Dissolved P-5mg/l (preferable 2mg/l).) shall be maintained as per CPHEEO mannuals Latest NGT norms for effluent discharge shall be adhered. The rate is Considered for SBR Technology. The STP shall be capable to treat the raw sewage having minimum concentration mentiond in CPHEEO mannual. Firm has to complete Design, Supply, Erection, Testing,Commissioning and 3 month trial run of Substation Work like HT Panel, Transformer & its associated equipments and DG Set Work with AMF Panel with considering load of STP and MPS both. Design, Supply of all Materials, Erection and Commissioning and 3 month Trial Run of Co-Treatment Plant ( 16 KLD ) having manual screen with-SS 304 with bar size (50 mm x 10mm) and gaping 20 mm, Screw Pumps (3 Kl/h 1W+1S), Screw Press Machine (3KL/H), all type pipe and fittings, LT panel and cabling material,Dewatering Pumps (1W+ 1S), 5 HP Blower with 6 Nos Diffusers etc complete. including Supply and 3 month trial run. E&M WORK AT MPS Electrical Works H.T.Panel( Comprising with 1 -I/C and 2 -O/G. SITC of Indoor Type Floor mounted HT Panel with 11 KV, 630 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details-

-

-

-

... More
Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630 Amps . VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement) - VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel. - Numerical relay (should be VCB manufacturer's own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI. - Ammeter with Selectorswitch and Volt meter with Selector switch - Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc. - Trip circuit supervision relay (feature of numerical relay) - LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. 1 Set Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630 Amps . VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure.

-

-

-

... More
Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement) - Numerical relay (should be VCB manufacturer's own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI. - Ammeter with Selectorswitch and Volt meter with Selector switch - Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc. - Trip circuit supervision relay (feature of numerical relay) - LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) - 2 Set Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. 3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) - 60 meter Trench making and covering of trench in all respect - 60 meter SITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) - 4 set 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV - 2.5 sqm Transformer (1w+1s) : Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of suitable capacity (designed as per load of stp & mps both) rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C & 40-45 degree C for above 800 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. (However actual capacity will be calculated at the time of execution , after approval of load list) - 2 Nos.

-

-

-

... More
D.G. SET AND ACCESSORIES SITC of suitable capacity (should be designed according to MPS & STP Load both) Radiator Cooled and Turbo charged Silent type DG set , engine ,alternator capable of developingrequired power at 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. it sould comply CPCB 4 (However actual capacity will be calculated at the time of execution, after approval of load list) -1 set SITC of PLC Based Auto main failure (AMF) Panel for DG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect. ( pwd bsr 2022- 23.29.3) - 1 set Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.( pwd bsr 2022- 14.1) - 2 Job Plate Earthing as per IS:3043 with copper Earth plate of purity 95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required.( pwd bsr 2022- 14.3) -2 Job

-

-

-

... More
Supply & Laying 50 mm X 6mm size GI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. - 40 Met Providing and Laying cable for DG Set to Panel 185 sq mm X 3.5 core x 2 run( armored aluminium ). -50 Met Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 185 sq mm.(pwd bsr-2022-item no 12.1.24)- 4 Job

1

31622522

31622522.35

... More
L.T. Panel SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operated on 415 ± 6 % volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii) C.Ts of suitable ratio- 1 No.(iii) Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v) Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi) Frequency meter-1 No.(vii) KWH meter - 1 No. (viii) 2 Pole over current relay& one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 6 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 160 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustable adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 3 Nos. outgoing panels for miscellaneous works, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (E)APFC Panel for total load.(F) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels

1

1663899

1663899.37

... More
LT Cable laying and jointing Power and control cable-Supply of 185 sq. mm 3.5 core cable - 2 Run required for power from each Transformer to each L.T. panel , 50 sq. mm X3 core-1 run cable for power from starters to Motor including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation system etc. complete in all respect.

1

291219

291219.76

... More
Earthing Plate Earthing as per IS:3043 with copper Earth plate of purity 95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.

4

14530

58122.68

... More
Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.

3

3495

10486.38

... More
Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing)

140

176

24717

... More
Charges of Electrical safety Clearance

-

-

-

... More
Expenditure on B&L Form, Challan etc.

1

9595

9595

... More
Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage)

1

115140

115140

... More
STARTER PANEL

-

-

-

... More
SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 15 KW motor (To be fixed in composite panel of LT Panel)-

6

67165

402990

... More
Mechanical Works Pump The submersible non clog pumpset should be single stage having two vanes enclosed impeller coupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (4W+2S) Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN. Impeller-Stainless steel CF-8M shaft-stainless steel AISI-410 Discharge of pump= 2610 lpm Total Head= 18 M Speed=980 Quantity of pumps. 06 nos. Guid Rail System Guide rail system (Automatic coupling system) for 20 HP submersible pump sets complete for above pump set. 06 sets Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle - 06 sets

-

-

-

... More
Quantity of pums

6

339239

2035439.16

... More
Main piping and Valves. Main piping and valves 200 mm dia delivery, 400 mm dia common header line. Valves. Confirming to IS 780/2906 or as applicable PN rating- 1.0 Type of liquid to be handled-potable water Material of construction Body-CI,IS-210 grade FG 200 Wedge-CI IS210 Grade FG200 Spindle-Stainless steel AISI304 Sheet and face Ring-SS ASTMA 743 Grade C.F.8 M Channel& Shoe-S.S.AISI,.304 Drain& Air plug-S.S.AISI.304 Bushing arrangement-Halprene on bronze Rivets-AISI:304 Fasteners-MS Motor Operated Sluice Valves

-

-

-

... More
Moter operated Sluice Valve 200 mm dia

6

143925

863550

... More
Moter operated Sluice Valve 400 mm dia

1

326230

326230

... More
Reflux valve 200 mm dia N.B.

6

45112

270676.86

... More
PIPING Note : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing taking 200mm pipe 60m and 350 mm pipe 15m .

-

-

-

... More
200 mm, K9 delivery pipes for all six pumping plant

60

2443

146631

... More
400 mm, K9 common header pipes

15

6207

93105.15

... More
Specials like bend, tee, D Joint etc.@ of 5%

1

11986

11986.79

... More
Nut Bolt, Washer Rubber packing etc @ of 5%

1

12586

12586.13

... More
Installation & Commissioning of all 6 Nos. Pump set,Piping & Valves as mentioned in above @10% of supplied items.

1

376020

376020.48

... More
Level Transmitter (For Hi-Lo cut-off & alarms) SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display.

1

115140

115140

... More
Electro magnetic flow meter SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line.

1

402990

402990

... More
E.O.T. Crane SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating m

1

644029

644029.83

... More
Chequerred plate and guards SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition (3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm.

235.17

97

22882.04

... More
PAINTING Painting of all pumps piping and valves with two coat enamel paint.

6

2878

17271

... More
LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019)

-

-

-

... More
Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan

1

19190

19190

... More
Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan

1

19190

19190

... More
IPS Campus with Solar Panel and LED Light of 3 sets.

1

86355

86355

... More
SCREENS AND GATES:

-

-

-

... More
Rising type thimble mounted CI Sluice Gates of reputed make at IPS

4

287850

1151400

... More
Stainless Steel Manual Screen (20 mm gaping) with bar size 50 mm x 10 mm and 1 no pungi for both manual screens (1working+ 1standby)

2

211090

422180

... More
Packing and Frieght @ 3% of ( 25 & 26 )

1

47207

47207.4

... More
Installation, Testing and Commissioning @ 10% of (25&26)

1

157358

157358

... More
AUTOMATION OF MPS CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places.

1

263862

263862.5

... More
GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification.

1

28785

28785

... More
CE/UL certified intellignet Smart Energy Meter

1

23987

23987.5

... More
Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 160 AMP rating

1

67165

67165

... More
Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator.

7

47975

335825

... More
CE/UL Certified Surge protector for control panel.

1

14392

14392.5

... More
CE/UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control ofp rocess parameters.

1

28785

28785

... More
Security Survillance IP Camera with recorder

1

19190

19190

... More
Installation, commissiong & testing of above automation work

1

19190

19190

... More
Trial run of automation work for 3 month period for MPS

1

14392

14392.5

... More
Three month Expenditure on Operator (MPS) in 3 Shift

3

47495

142485.75

... More
Diesel Consumption During Trial and Run Period (MPS & STP both)

1

227991

227991.59

... More
Electricity consumption during period of Trail and Run period, payment will be done as UPPCL Bill for MPS and STP both

1

551336

551336.16



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.