State Bank Of India Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

State Bank Of India - SBI Tender

Goods
Electrical Goods and Equipments
Electrical and Electronics
GEM
Opening Date11 Feb 2025
Closing Soon4 Mar 2025
Tender Amount₹ 1,20,82,480 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
HT SECTION:

-

-

-

... More
Supply, Design, Testing, Transportation, Installation and Commissioning of 11kV 800Amps 26.3kA HT VCB Panel (1Incomer + 2Outgoing) with Al Bus Bar consisting of following components :

-

-

-

... More
HT SWITCHGEAR Rating:

-

-

-

... More
11KV 800A, 26.3KA Truck mounted Horizontal Isolation & Horizontal Drawout type Vacuum Circuit Breaker Incomer : 800A- 01 Nos. Outgoing : 800A: 02 nos. consisting of (D) One number direct module for incoming cable and Vacuum Circuit Breakers in SF6 insulated robotically welded non ferrite non magnetic stainless steel enclosure of thickness 2.5mm having IP67 with series trip, Self powered microprocessor based numerical over current and Earth Fault (IDMT+Inst.) relay protection. Interconnection between HT switchgear and transformer shall be using 1C x 3 x 240 sq.mm Al armorured XLPE HT Cable.(Make: Schneider/ABB/Crompton/CG Power/Seimens/LK/GE)

-

-

-

... More
Fabricated Housing :

-

-

-

... More
Housing with Al 800A Interconnections Incomer : 800A- 01 Nos. Outgoing : 800A: 02 nos.

-

-

-

... More
800A Al Bus Bar with 11KV Grade Sleeving (Extension for future 4th VCB) Incomer : 800A- 01 Nos. Outgoing : 800A: 02 nos.

-

-

-

... More
CT & PT DETAILS :

-

-

-

... More
DUAL CORE CT CTR : 150/5/5A Core 1 : Class 1, BURDEN 15 VA Core 2 : Class 5P10, BURDEN 15 VA (CT need to be 50 A) CT Position shall be in Cable Chamber of Panel Incomer : 03 Sets Outgoing : 06 Sets

-

-

-

... More
3 No. Single Phase Potential Transformer (To be mounted at the rear end of the Panel and position will be above breaker position) Ratio : 11KV/rt3/110V/rt3 Class 1, BURDEN - VA Material - Cast Resin type Incomer : 01 Sets Outgoing : 00 Set

-

-

-

... More
BREAKER PANEL INDICATION LAMPS :

-

-

-

... More
Breaker On / Off / Trip / Spring Charge ( As required) Incomer : 05 Sets Outgoing : 10 Sets

-

-

-

... More
R-Ph. / Y-Ph. / B-Ph Incomer : 03 Sets Outgoing : 00 Sets

-

-

-

... More
SWITCHES AND OTHER ACCESSORIES :

-

-

-

... More
DC ON/OFF Switch Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
AC ON/OFF Switch Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
Local Remote Switch Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
T-N-C Switch Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
15A, 230V, 3 pin plug plug & socket Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
Mech. ON-OFF push button Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
Heater with heater switch & thermostat Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
Cubicle illumination lamp Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
METERS :

-

-

-

... More
MFM EM6400 Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
Ammeter with Selector Switch Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
Voltmeter with Selector Switch Incomer : 01 Sets Outgoing : Sets

-

-

-

... More
RELAYS :

-

-

-

... More
Numerical Non -Directional 3 Over Current/ 1 Earth Fault Protection- P1F1 Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
Trip Ckt Supervision Part of Main Numerical Relay

-

-

-

... More
Antipumping Incomer : 01 Sets Outgoing : 02 Sets

-

-

-

... More
Master Trip Part of Main Numerical Relay

-

-

-

... More
Auxillary Relay for Trafo Fault (VAA33 or Equiv.) Incomer : Sets Outgoing : 02 Sets

-

-

-

... More
Power Pack Incomer : 01 Sets Outgoing : 00 Sets

-

-

-

... More
8 Window Annunciator with Hooter Incomer : 01 Sets Outgoing : 00 Sets

-

-

-

... More
Relay shall be with communication port

-

-

-

... More
Protection CT shall be 40/1A 2.5VA 5P10.

-

-

-

... More
Mechanical ON-OFF-TRIP mimic diagram

-

-

-

... More
Fault Passage Indicator

-

-

-

... More
Manometer

-

-

-

... More
Terminal Protectors ( BOOTS)

-

-

-

... More
Operating Handle

-

-

-

... More
Incoming and Outgoing modules of the RMU shall be suitable for 3C x 400 sq.mm HT 11 KV Cable termination Incoming  Cable termination kits shall be in Purchaser Scope

-

-

-

... More
Sub Total( A)- Supply, Design, in house Testing of 11kV 800Amps 26.3kA HT VCB Panel (1Incomer + 2Outgoing) as Described as Above.

1

-

-

... More
(B)- TRANSFORMERS

-

-

-

... More
Supply, Installation, Testing and Commissioning of 1000 KVA 11/0.433 KV Delta-Star DYn11 COPPER Wound (HV and LV), ONAN Oil immerged type transformer with On Load Tap change(OLTC) tap links of range +5% to - 15% @ 2.5% each. Insteps of 2.5% each total 8 steps. Class of Insulation: A, Temperature Rise: 98 Deg. C, Losses (As per ECBC 2017) (Subjected to IS Tol.). Minimum 3 Star rated. (Make: Schneider/ABB/Crompton/CG Power/Seimens/LK/GE/BHEL)

-

-

-

... More
1. Type of Cooling : ONAN

-

-

-

... More
2. Class of insulation Class A

-

-

-

... More
3. No of phase and rated frequency : 3, 50 Hz

-

-

-

... More
4. Winding

-

-

-

... More
a) HV Copper

-

-

-

... More
b) LV Copper

-

-

-

... More
5.. Insulation level ( Impulse withstand )(kVpeak)

-

-

-

... More
a) HV 75

-

-

-

-

-

-

... More
6. Insulation level ( power frequency withstand ) (kVrms)

-

-

-

... More
a) HV 28

-

-

-

... More
b) LV 3

-

-

-

... More
7. Tapping

-

-

-

... More
a) Range +5% to -15% @ 2.5% Each

-

-

-

... More
b) No of Steps 8

-

-

-

... More
c) On HV yes

-

-

-

... More
d) Tap changer type OLTC

-

-

-

... More
8. Temperature rise of oil/winding over design ambient temperature of 50°C : 40/45( °C)

-

-

-

... More
9. Hot spot temperature rise over a maximum yearly weighted : 98 °C

-

-

-

... More
10. Short circuit Thermal withstand time (secs) : 2

-

-

-

... More
11. % Impedance at 75°C , rated current &Frequency % (subject to IS tol) : 5

-

-

-

... More
12. Total losses @ 50% Load at rated voltage & frequency kW (MAX) : 2.79

-

-

-

... More
13. Total losses @ 100% Load at rated voltage & frequency kW (MAX) : 7.7

-

-

-

... More
14. Bushings : HV

-

-

-

... More
a) Reference standard : IS 2099 & IS 3349

-

-

-

... More
b) Type of bushing : Porcelain

-

-

-

... More
c) Voltage Rating (kV) : 17.5

-

-

-

... More
d) Current Rating Amps : 250

-

-

-

... More
15. Bushings : LV & LVN

-

-

-

... More
a) Reference standard

-

-

-

... More
b) Type of bushing : Epoxy

-

-

-

... More
c) Voltage Rating (kV) : 1

-

-

-

... More
d) Current Rating Amps : 2000

-

-

-

... More
16. Weight in Kgs (Approximate)

-

-

-

... More
a) Core and winding : 2350

-

-

-

... More
b) Tank &Fittings : 1800

-

-

-

... More
c) Oil :1200

-

-

-

... More
d) Total weight : 5350

-

-

-

... More
17. Approximate Overall dimension (in mm)

-

-

-

... More
a) Overall Length : 3300

-

-

-

... More
b) Overall breadth : 3100

-

-

-

... More
c) Overall Height : 2500

-

-

-

... More
18. Approximate Weight of Heaviest package (KG) : 4100

-

-

-

... More
19. Approximate transport dimensions LxBxH (mm) : 3300 X2000 X 1800

-

-

-

... More
20. Fitting & Accessories as per specification Yes, IS : 2026 & CBIP

-

-

-

... More
21. Reference standard : IS 1180 & IS:2028

-

-

-

... More
22. Termination

-

-

-

... More
a) HV Cable Box : (1 Run / Ph)

-

-

-

... More
b) LV Cable Box : (4 Run / Phase) B2B

-

-

-

... More
c) Orientation : 182 Degree

-

-

-

... More
Sub Total (B) :11/0.433 KV, 1000 KVA ONAN Type Transformer Described as Above.

2

-

-

... More
(C )- HT Cabling

-

-

-

... More
11 KV END TERMINATION:

-

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
3C x 240 Sqmm, 11KV XLPE

6

-

-

... More
11 KV H.T. CABLE:

-

-

-

... More
Supply of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required.

-

-

-

... More
3C x 240 Sqmm, 11 KV XLPE

80

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in existing trench including excavation and dismanteling of existing cable, protective covering and refilling with repair the trench etc as required.

-

-

-

... More
Above 120 sq. mm and upto 400 sq. mm

80

-

-

... More
Sub Total (C ) HT Cabling

-

-

-

... More
(D) -LT Cabling

-

-

-

... More
DISTRIBUTION CABLE:

-

-

-

... More
SUPPLY AND LAYING OF LT CABLE:

-

-

-

... More
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated and FRLS PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by Engineer In charge/ architect / consultant).

-

-

-

... More
3.5 core, 400 sq.mm.

320

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, sand cushioning, dismanteling and safe keeping of existing cable, protective covering and refilling with repair the trench etc as required

-

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

320

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3½ X 400 sq. mm

16

-

-

... More
Sub Total (D ) LT Cabling

-

-

-

... More
(E )- Earthing and other works

-

-

-

... More
Earthing with G.I. plate 600mmx600mmx6mm thick, top of the plate placed at least 3 mt. below ground level with 20 mm Class-B, G.I. pipe for watering, as per IS 3043, with 32x6 mm GI earthing strip in 50mm B class GI pipe from plate to masonry inspection pit, with salt and charcoal and providing 12 mm diax 80mm long GI bolt, nut and double washers for connecting earth lead including restoring the surface duly rammed as per specification with 300 mmX300mmX300mm(inside) finished masonry chamber with 8 mm thick MS sheet hinged,lockable cover and MS frame on top of chamber.

4

-

-

... More
Earthing with copper plate 600mmx600mmx3mm thick, top of the plate placed at least 3M below ground level with 20 mm Class-B, G.I. pipe for watering as per IS 3043-1987 with 32x6 mm Cu earthing strip in 40 mm B class GI pipe from plate to masonry inspection pit, with salt and charcoal including passivated 2 mm diax80 mm long brass bolt, nut and double washers for connecting earth lead including restoring the surface duly rammed as per specification with 300 mmX300mmX300mm(inside) finished masonry chamber with 8 mm thick MS sheet hinged,lockable cover and MS frame on top of chamber.

4

-

-

... More
Providing and fixing earth bus of 40 mm X 6 mm copper strip on surface or underground as required for connections etc. as required.

70

-

-

... More
Providing and fixing 40 mm X 6 mm G.I. strip on surface or in recess or underground as required for connections etc. as required.

120

-

-

... More
Dismanteling, shifitng at suitable place in same premises and safekeeping of existing 02 nos. 1000KVA 11/0.433 KV old transformer and Oil Circuit Breaker(OCB) (1 Incoming and 02 Outgoing)

1

-

-

... More
Charges for liaisoning with power supply and other statutory authorities like Directorate of electrical Safety for obtaining necessary clearances/ approvals including preparation of drawings, filling up norms, follow-up on behalf of Employer etc. in connection with the subject installation and getting power supply shut down and restoration from UPPCL.

1

-

-

... More
Sub Total (E )- Earthing and other works

-

-

-

... More
GRAND TOTAL (A+B+C+D+E)

-

-

-

... More
GST…......@.......%

-

-

-

... More
Total amount including GST

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.