State Bank Of India Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

State Bank Of India - SBI Tender

Goods
Electrical Goods and Equipments
Electrical and Electronics
GEM
Opening Date14 Feb 2024
Closing Date28 Feb 2024
Tender Amount₹ 17,62,450 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.5 Tr Hi Wall Split AC , Supply of 1.5 Tr 5 star inverter Hi wall split AC unit with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details.

5

-

-

... More
1.0 Tr Hi Wall Split AC , Supply of 1.0 Tr 5 star inverter Hi wall split AC unit with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details.

4

-

-

... More
Installation of VRV OR VRF Outdoor , Installation, testing and commissioning of VRV/VRF outdoor with necessary stand, Gas etc. including making good of damages complete in all respects.

2

-

-

... More
Installation of VRV OR VRF Indoor , Installation, testing and commissioning of VRV/VRF cassette indoor with necessary stand, Gas etc. including making good of damages complete in all respects.

6

-

-

... More
Installation of Hi wall Split AC , Installation, testing and commissioning of 2/ 1.5/ 1 TR Hi wall type split/window air conditioner with wall cutting/ mounting, stabiliser and making good of damages complete in all respects.

12

-

-

... More
Refrigerant piping 28.6 mm , Supply, installation, testing and commissioning of Interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details.

20

-

-

... More
Refrigerant piping 22.2 mm , Supply, installation, testing and commissioning of Interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details.

25

-

-

... More
Refrigerant piping 19.1 mm , Supply, installation, testing and commissioning of Interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details.

30

-

-

... More
Refrigerant piping 15.9 mm , Supply, installation, testing and commissioning of Interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details.

25

-

-

... More
Refrigerant piping 12.7 mm , Supply, installation, testing and commissioning of Interconnecting 12.7 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details.

25

-

-

... More
Refrigerant piping 9.5 mm , Supply, installation, testing and commissioning of Interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details.

40

-

-

... More
Refrigerant piping 6.4 mm , Supply, installation, testing and commissioning of Interconnecting 6.4 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details.

40

-

-

... More
Additional Copper pipe for split AC , Supply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber for 2/1.5/1 TR hi wall split AC. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details.

150

-

-

... More
Drain pipe 32 mm , Supply, installation, testing and commissioning of PVC 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. Refer technical specification and BOQ for details.

60

-

-

... More
Drain pipe 25 mm , Supply, installation, testing and commissioning of PVC 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. Refer technical specification and BOQ for details.

80

-

-

... More
Control and Transmission wiring , Supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. Refer technical specification and BOQ for details.

130

-

-

... More
Cable for Hi wall split AC , Supply, installation, testing and commissioning of inter connecting wiring/ cabling between indoor and outdoor of 2/1.5/1 Tr hi wall split AC. Refer technical specification and BOQ for details.

160

-

-

... More
Cable Tray , Supply & Laying of Cable Tray 300 mm GI for Copper Pipes & Cables

120

-

-

... More
Outdoor Stand for VRV or VRF , Supply and installation of robust MS angle, MS flat fabricated floor/ wall mounting stand suitable for VRF/ VRV outdoor units. Refer technical specification and BOQ for details.

2

-

-

... More
Outdoor Stand for split AC , Supply and installation of robust MS angle, MS flat fabricated floor/ wall mounting stand suitable for hi wall split/ cassette outdoor units. Refer technical specification for details.

10

-

-

... More
Stabiliser for 2Tr split AC , Supply of 5 KVA, wall mounted hi lo cut off stabiliser with TDR, voltage range 140-280V, complete in all respects. Refer technical specification for details.

1

-

-

... More
Stabiliser for 1.5 or Tr Hi wall split AC , Supply of 4 KVA, wall mounted hi lo cut off stabiliser with TDR, voltage range 140-280V, complete in all respects. Refer technical specification for details.

9

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.