Rajya Krishi Utpadan Mandi Parishad Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Rajya Krishi Utpadan Mandi Parishad - RKUMP Tender
Eprocure
Opening Date7 Dec 2020
Closing Date30 Dec 2020
Tender AmountRefer Documents
Costs
EMD
₹ 1,97,000Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_RKUMP_535772_1Bid Award Id
ViewTender No
64/2020/385 MANJHANPURTender Authority
Rajya Krishi Utpadan Mandi Parishad ViewPurchaser Address
-Website
http://etender.up.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply & fixing steel tubular pole 9.50 Metre long designated 410 SP-36 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respects. 616
5
-
14028
S/F of overhead line with ACSR conductor on poles/service bracket including binding etc. complete in all respects. 627
497
-
263
Tighting of overhead line with ACSR conductor on poles/service bracket including binding etc. complete in all respects. 627 LR
785
-
27
S/F of overhead line with G.I. wire no. 8 to 4 SWG on poles/service bracket including binding etc. complete in all respects. 628
54
-
66
Tighting of overhead line with G.I. wire no. 8 to 4 SWG on poles/service bracket including binding etc. complete in all respects. 628 LR
143
-
27
S/F of Spacer in over head L.T. line including labour etc. complete in all respects. Appd
360
-
96
S/F of 100 Amp four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer-in- charge. 378
1
-
8750
Supply & erection of stay set at 3.5 Metres away from the pole complete with galvanised 19mm dia x 1.80 Metre long stay rod, 30 cm x 30 x 6.3mm anchor plate, thimble stay clamps, stay insulator, 19mm 600mm double screw tightener, 7/13.5mm G.I stay wire etc. in 1:3:6 cement concrete complete in all respects. 631
6
-
3029
Supply & fixing of 100mm x 100mm shackle insulator/100mm x 80mm pin insulator including G.I. Bolts/spindle nuts etc. complete in all respects. 621
13
-
79
Supply & fixing of 230mm x 32mm x 1.5mm galvanized steel strips including holes for shackle insulators pins and bolts etc. complete in all respects. 622
10
-
113
Supply & erection of “D” clamps of 50mm x 6mm flat iron on steel tubular poles/steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint. 623
12
-
223
S&F of 100 A. 415 V Metal clad TPN HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. 328
1
-
7750
Sifting of steel tubular pole 9.50 Metre long designated 410 SP-36 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respects. 616 LR
4
-
1299
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (a) 25sq. mm 3-1/2 core 501 (J)
100
-
373
(B) 16sqmm 4 core 501 (I)
240
-
343
(C) 6sqmm 2 core 501 (A)
220
-
276
Wiring point for light in 1.5 sq. mm. FRLSH PVC insulated single core alumunium conductor cable (drawn through existing concealed steel conduit) and 5 Amp. Flush type switch & ceiling rose/angle/batten holder fixed with 3mm thick phenolic laminated backalite sheet with brass machine screws and cup washers mounted over existing M.S. switch board box/junction box with supply of all material, labour & T&P etc. required for proper completion of the work as directedat site by the Engineer in charge. 174 B
20
-
350
Wiring point for celling fan in 1.5 sq. mm. FRLSH PVC insulated single core alumunium conductor cable (drawn through existing concealed steel conduit) and 5 Amp. Flush type switch & ceiling rose/angle/batten holder fixed with 3mm thick phenolic laminated backalite sheet with brass machine screws and cup washers mounted over existing M.S. switch board box/junction box with supply of all material, labour & T&P etc. required for proper completion of the work as directedat site by the Engineer in charge. 177 B
4
-
428
Wiring point for point plug in 1.5 sq. mm. FRLSH PVC insulated single core alumunium conductor cable (drawn through existing concealed steel conduit) and 5 Amp. Flush type switch & ceiling rose/angle/batten holder fixed with 3mm thick phenolic laminated backalite sheet with brass machine screws and cup washers mounted over existing M.S. switch board box/junction box with supply of all material, labour & T&P etc. required for proper completion of the work as directedat site by the Engineer in charge. 178 B
4
-
188
S & F of 6 Amp to 32 Amp SP MCB(10KA) . CAT A 1002
4
-
260
S&F of 6 Amp to 32 Amp DP MCB(10KA) . CAT A 1009
2
-
740
Supply and fixing of LED street light fitting having die cast aluminium body and diffuser/ Reflector with driver set suitable for 45 to 50 Watt. Confirming to IP 66 Protection complete in all respect. CAT-AAA 1421
2
-
4940
Supply and fixing of LED tube Light with batten suitable for up to 2 x 22 watt LED tube light complete including tube etc. On surface complete in all respect. 1414
25
-
1790
S/F of decorative 8 to 16 watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. 1442
25
-
4070
S/W of submains with 2 Nos. 4 sq mm & with 1 No earth wire of 2.5sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in exiting PVC conduit complete, including supply of all material, labure and T & P etc. required for proper completion of the work as direction by Engineer in charge. 291 A
60
-
103
S/W of submains with 2 Nos. 4 sq mm & with 1 No earth wire of 2.5sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in exiting PVC conduit complete, including supply of all material, labure and T & P etc. required for proper completion of the work as direction by Engineer in charge. 291 L
50
-
518
Supply and Fixing of decorative shape 40 to 45 Watt LED Post top latern luminaire having powder coated die cast aluminium body and diffuser of polyethylene material with driver set confirming to IP 65 Protection complete in all respect. CAT-AAA 1443
15
-
8410
S/F of 3 H.P. Submersible pump KSB Make
1
-
27700
S/F of 50mm dia G.I. pipe
20
-
560
S/F of 50mm dia Socket
10
-
125
4 sq mm copper wire
55
-
110
S/F of Starter for 3 H.P. Pump
1
-
8500
S/F of wire rope
55
-
30
Labour charge for lifting pump
1
-
10500
Labour charge for lowering pump
1
-
3000