Rural Engineering Department Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Rural Engineering Department Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date3 Jan 2025
Closing Date23 Jan 2025
Tender Amount₹ 14,08,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. DSR 2022 No. 1.14 Circuit / Sub main wiring in PVC conduit :-

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. DSR 2022 No. 1.14.1

300

-

53145

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. DSR 2022 No. 1.14.2

250

-

52271.25

... More
2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire DSR 2022 No. 1.14.4

150

-

50067

... More
2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire DSR 2022 No. 1.14.5

100

-

43338

... More
Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. DSR 2022 No. 1.29 S/F light plug point piano type accessories :-

5

-

1360.95

... More
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. DSR 2022 No. 1.30 S/F power plug point piano type accessories :-

5

-

1855.15

... More
Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 poles and earth metal enclosed plug top along with 20 amps. "C" curve, SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. DSR 2022 No. 2.18

4

-

4929.84

... More
Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR 2022 No. 1.25 S/F modular type electronic fan regulator :-

16

-

4488.8

... More
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. DSR 2022 No. 1.26 S/F modular type blanking plate :-

6

-

182.46

... More
Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : DSR 2022 No. 1.21

-

-

-

... More
20 mm. (1.21.1)

50

-

4866

... More
25 mm. (1.21.2)

60

-

6614.4

... More
32 mm. (1.21.3)

20

-

2798

... More
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR 2022 No. 2.10

-

-

-

... More
single pole (2.10.1)

10

-

1946.4

... More
Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required. (2.11)

4

-

39.52

... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. DSR 2022 No. 2.12 S/F DP MCB Isolator

-

-

-

... More
40 Amps (2.12.1)

1

-

330.73

... More
63 Amps (2.12.2)

1

-

400.68

... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. DSR 2022 No. 2.13 S/F TP MCB Isolator

-

-

-

... More
63 amps. (2.13.2)

2

-

1572.32

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.DSR 2022 No. 2.14

-

-

-

... More
40 amps. (2.14.2)

1

-

2008.74

... More
63 amps. (2.14.3)

1

-

2069.56

... More
Supplying and fixing following rating, four pole, (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensivity current upto 300 miliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required : DSR 2022 No. 2.15

-

-

-

... More
63 amps. (2.15.3)

2

-

4367.22

... More
Supplying and fixing following way, SP&N, sheet steel, MCB distribution board, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) DSR 2022 No. 2.30

-

-

-

... More
6 way, Double door (2.3.1)

2

-

3354.48

... More
Supplying and fixing following way, horizontal type TP&N, sheet steel MCB distribution board, 415 V on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). DSR 2022 No. 2.4

-

-

-

... More
4 way (4 + 12), Double door (2.4.1)

2

-

6220.84

... More
Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/ coke and salt as required. DSR 2022 No. 5.4

1

-

5681.03

... More
Supplying and laying 25 mm x 5 mm. G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) DSR 2022 No. 5.9

25

-

2737

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR 2022 No. 5.11

20

-

10735.6

... More
Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required. DSR 2022 No. 5.15

25

-

4638

... More
Providing and fixing M.V. danger notice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription single red colour on FRLSont side as required. DSR 2022 No. 2.21

1

-

204.52

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. DSR CIVIL 10.18

16

-

2570.56

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. DSR CIVIL 1.18

-

-

-

... More
2 Pair (1.18.2)

120

-

3466.8

... More
Supplying and drawing Co axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. DSR CIVIL 1.19

-

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable DSR 2022 No. 1.53.2

50

-

3649.5

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. DSR 2022 No. 1.24

-

-

-

... More
5/6 A switch (1.24.1)

11

-

861.41

... More
3 pin 5/6 A socket outlet (1.24.4)

10

-

927.6

... More
Telephone socket outlet (1.24.6)

4

-

450.12

... More
TV antenna socket outlet (1.24.7)

-

-

-

... More
Bell push (1.24.8)

4

-

425.76

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. DSR 2022 No. 1.27

-

-

-

... More
1 or 2 Module (75mmX75mm) (1.27.1)

5

-

1132.85

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. DSR 2022 No. 1.31

6

-

2176.02

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. DSR 2022 No. 1.32

6

-

2673.24

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. DSR 2022 No. 1.38

2

-

150.54

... More
Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. DSR 2022 No. 1.41

10

-

1566.2

... More
Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. DSR 2022 No. 1.45

16

-

4123.84

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required DSR 2022 No. 1.50

-

-

-

... More
Upto 450 mm sweep (1.50.1)

24

-

8211.36

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. DSR 2022 No. 19.1

16

-

33210.24

... More
Supply of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.. CATAAA PWD SOR 2018 Electrical S.l.No.1406

8

-

39040

... More
Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. CATAAA PWD SOR 2018 Electrical S.l.No.1413

45

-

53550

... More
Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 2X22 watt suitable for upto 2X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. CATAAA PWD SOR 2018 Electrical S.l.No.1414

18

-

32220

... More
Supply of recess/surface mounting round 10 W to 15 W LED Cut out Min 125 mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. suitable for 24Hr Continuous Operation, Complete in all respect. CATAAA PWD SOR 2018 Electrical S.l.No.1402

12

-

16200

... More
Supply of 225/230mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. S.E.R.E.D. MBD

-

-

-

... More
300 mm sweep

24

-

61440

... More
Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with detachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. Incoming : (200 Amp TPN-1 No.) Outgoing

-

-

-

... More
100 Amp TPN-1 No and 63 Amp TPN-3 Nos CAT B Cubicle Type PWD SOR electrical S.l.No 802 C

1

-

80900

... More
Supply of fixing of 40 Amp 4 pole MCB (10KA) CAT A PWD SOR electrical S.l.No 1020

2

-

4550

... More
Supply of fixing of 100 Amp 4 pole MCB (25 KA) Thermal Magnetic release CAT A PWD SOR electrical S.l.No 1021C

1

-

8140

... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PWD SOR 2018 S.l.No.501

-

-

-

... More
16 sq. mm 4 core (i)

120

-

41160

... More
35 sq. mm 3-1/2 core (k)

110

-

46420

... More
50 sq. mm 3-1/2 core (l)

80

-

39360

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. DSR 2022 No. 9.1

-

-

-

... More
16 sq. mm 4 core (9.1.33)

5

-

1174.7

... More
3½ X 35 sq. mm (35mm) (9.1.21)

8

-

2244.4

... More
3½ X 50 sq. mm (35mm) (9.1.22)

4

-

1256.04

... More
For Air Conditionar S & F of 6 Amp to 32 Amp TP MCB (10 KA) C Curve CAT-A 1013 Rate of PWD E&M 2018

4

-

4760

... More
Supply and wiring of submain with two number 6 sq mm FRLSH PVC insulated 1100V grade multistrand single core copper conducture in 25 mm dia heavy duty (2 mm thick) PVC Conduit with one No.4 Sq mm FRLSH PVC insulated mutistand copper conducture cable as earth continuity wire drawn in conduit. 217C SOR 2018 E&M

55

-

11825

... More
Supplying Installation of split direct expansion air conditioners suitable on operation on AC Supply single phase 50Hz 230Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitor, relay and over load protector internal unit, with one indoor unit and outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/Cordless) Suitable capacity 3Core shearthed /PVC copper cable and a battery operated wireless remote (1.5 Ton) 1503B BEE Star Rated : 5 Star, EER 3,4

4

-

172000

... More
Supply and fixing of 4KVA (150v to 280v) Copper wound stabilizer vailed upto 2.00 KVA tonne A.C. Approved by SE RED MBD

4

-

27200



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.